USERS MANUAL ATTACHMENT F Road Weigher RW-2601PRF
Owner's Manual Federal Commission Communications Requirements Warning : Changes or modifications not expressly approved by the party responsible for compliance with the FCCS rules could void the user's authority to operate the equipment. NOTE : This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communication. However, there is no guarantee that interference will not occur in a particular installation. If this equipment dose cause harmful interference to radio or television reception. Which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures :
- Reorient or relocate the receiving antenna.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is Increase the separation between the equipment and receiver connected.
- Consult the dealer or an experienced radio/TV technician for help
* * * Contents * * *
1. Preface 2. Features 3. Specifications Dimensions Specifications 4. Front Panel 5. Test Mode 6. Calibration Mode 7. Set Mode 8. Weighing Mode 9. Error Message and Trouble 1 2 6 7 8 11 13 16 18 1. Preface We greatly appreciate for your purchase of the CAS RW-
2601PRF. These goods have hold excellent performance and splendid properties through strike tests as well as devoting ourselves under severe quality management. Before using RW-2601PRF, it is recommended to read this manual carefully and to apply the function application fully.
Cautions
Do not press the keys hardly, for the keys are in operation with soft touch.
Keep away RW-2601PRF from the rain. Avoid sudden temperature change. Do not install RW-2601PRF in a place with high voltage and excessive electrical noises. Keep it in dry place. Do not use under direct rays. Do not use at the place with excessive electrical noises and vibration. 2. Features Up to 6 axle(P/F) scales 10 Compact size & light weight Box type Built in Battery Charger & Large capacity Battery Back-Light Function Optional Printer 3. Specifications Dimensions
Specifications ITEM Description Operating Power Inner Battery Operation.(DC6V) Power Source AC 120V, 60 Hz
(For Battery Charger) Display LCD 6 Digit (25 mm) Sub display Stable, Zero, Net Product Weight 9.2 kg Option Built -in Printer Frequency 903.000Mhz < 918.500Mhz Communication method FSK (Frequency Shift Keying fsk) Comm. speed Comm. distance Display below zero Battery life time Battery charging time Power consumption Temperature range 9600bps Max. 100M
- display Approx. 20 hours Approx. 12 hours 12 W
-10 <+40 4. Front Panel
(1) Display Lamp STABLE :
NET : ( ), ( ) ZERO TARE Static Motion kg lb SUM PRINT TRUCK No. ENTER ZERO : 0 POWER : Supply AC POWER SOURCE. CHARGE : Green Lamp -> Charging is completed. Red Lamp -> It is charging.
(2) Key Functions Numeric keys
- TEST, CAL, SET Mode :Used to enter numerical data.
- Normal Mode : (1, 2, 3, 4, 5, 6 key) Used to select platform that you wish to display weight CLEAR key : Used to clear erroneous entries in CAL, SET, and TEST mode.
, key
- Used to enter minimum division in CAL mode. ZERO key : Used to remove small variations in the scale's zero. PRINT key : Used to print transactions. SUM key :
Used to print total weight. Truck no. key :
Used to enter truck number. ENTER key :
- Used as an ENTER key.
(3) How to go to TEST mode Press the Truck no. key and ON/OFF key.
(4) How to go to SET mode Press the ENTER key and ON/OFF.
(5) How to go to CAL mode Turn on the power while pressing the ZERO key and then press the TARE key within 1 second. 5.TEST MODE
(1) How to go to Test mode Press the Truck no. key and ON/OFF key.
(2) Key Functions Numeric key : Used to enter numerical data. ENTER key : Used to go to next menu.
(3) Test Menu(TEST 1 - TEST 4) TEST 1 : Key Test TEST 2 : LCD Display Test TEST 3 : Load Cell and A/D conversion Test TEST 4 : Serial interface and Printer Test
(RS-232) TT EE SS TT Key Test Key ENTER key :
Next menu Other key :
Perform test TT EE SS TT Display Test Key ENTER key:
Next menu Display tESt1 Descriptions 1 Press any key to test then code of the key is displayed. Descriptions Display tESt2 88888 Test 2 is performed automati ally REF 1. You will go to TEST 3 automatically after completing TEST 2. TT EE SS TT A/D Conversion Test (Load Cell Test) Key Display Descriptions ENTER key:
Next menu tESt 3 5500 Display shows digital value of current weight. This value means REF 1. Check whether digital value is changing.If the digital value is fixed or zero is displayed, please check the connection of the load cell. TT EE SS TT 44 Serial Interface and Printer Test Key LIGHT key :
Exit test mode Other key :
Perform Display tESt4 GOOD ERR06 Descriptions No error in printer Check printer connector Sample Print out :
TEST OK 6. CALIBRATION MODE
(1) How to go to Calibration Mode Turn on the power while pressing the ZERO key and then press the TARE key within 1 second.
(2) Key Functions Numeric key : Used to enter numerical data. ENTER key : Used to go to next menu.
(3) Calibration Menu(CAL 1 - CAL 5) CAL 1 : Set Up Maximum Capacity CAL 2 : Set Up Minimum Division CAL 3 : Set Up Setting Weight CAL 4 : Zero Calibration CAL 5 : Span Calibration CC AA LL 11 Set Up Maximum Capacity RANGE ---> 1 < 99,999 kg Key Display Numeric key :
Increase or decrease the number CAL 1 100 10000 ENTER key : Save and Descriptions 100 kg 10000 kg REF 1. The maximum capacity means the maximum weight that scale can measure. CC AA LL 22 key : Input the Set Up Minimum Division RANGE ---> 0.0005 < 100 kg Display Key CAL 2 1 0.01 next division.
( 0.001 < 50 ) ENTER key : Save and Descriptions 1 kg 0.01 kg REF 1. The minimum division means the value of one division. REF 2. External resolution = One division/Maximum weight External resolution should be within 1/10,000. CC AA LL 33 Setting Weight RANGE ---> 1 ~ 99,999 kg Key Numeric key :
Increase or decrease the number ENTER key : Save and go to next menu Display CAL 3 100 10000 100 kg 10000 kg Descriptions REF 1. The weight should be within the range of 1 % < 100 % of maximum weight. REF 2. Setting Weight should be bigger than the 10% of Maximum Capacity. REF 3. Setting Weight should not be bigger than the Maximum Capacity. CC AA LL 44 Zero Calibration Key Display Descriptions ENTER key:
Zero calibration and go to next menu. CAL 4 UnLoAd
GOOD Remove the weight from the platter and press the ENTER key Under zero calibration Zero calibration is completed. REF 1.If zero calibration is done without any error, GOOD message is displayed and you can go to CAL 5 automatically. REF 2.If you want to finish CAL mode, press the SET key after zero calibration. CC AA LL 55 Span Calibration Key Display Descriptions ENTER key :
Span calibration CAL 5 LoAd
GOOD Load the weight which was set in CAL 3 and press ENTER key. Under span calibration. Span calibration is completed. Remove the weight and press the ENTER key, you will go to normal d REF 1. If Span calibration is done without any error, GOOD message is displayed REF 2. If the span is low, Error message (ERR 24) is displayed. Span calibrate with lower resolution. 7.SET MODE
(1) How to go to Set Mode Press the ENTER key and ON/OFF.
(2) Key Functions Numeric key : Used to enter numerical data. ENTER key : Used to go to next menu. C key : Used to clear erroneous entries.
(3) Set Menu (F4 ~ F14) F04 : Digital filter F08 : Automatic Back-light F12 : RF channel F13 : The number of platform F14 : Option clock Designation of the velocity change on weight. Automatic Back-light 1 F08 1 0 F04
9 Less 1
Manual Back-light Vibration
Automatic Back-light 9
Vibration Much the Adjust according to the condition. set value Select RF channel (1-4) F12 1 1 4 4 The number of platforms (1-6) F13 1 1 2 2 6 6 Select option clock 0 Not used F14 1 Used How to set up date/time (Ex. 2001/3/21 13:10:01) LCD Display C1 99 Descriptions Year : 01 C2 12 Month : 03 C3 11 Day : 21 C4 13 Hour : 13 C5 10 Minute : 10 C6 01 Second : 01 8. Weighing Mode
(1) How to go to Weighing Mode Press the ON/OFF key.
(2) Operations Key Usage Numeric Key: 1,2,3,4,5,6...0 key Used to select where to locate each alphabet or digit. ex) Press "3" key, the display shows t3.
(It means that you can enter third character of truck number) Key :The right arrow key is for when used from A to next alphabet, and the left arrow key is for in the reverse direction. ex) Key : t3 A --> t3 B Key : t3 B --> t3 A Key : The up arrow key is for when used from 1 to next number, and the down arrow key is for in the reverse direction. ex) Key : t3 2 --> t3 3(Increase the number) Key : t3 3 --> t3 2(Decrease the number) 1) How to enter Truck No. You can enter up to 8 digit for truck number. If you want to enter AB123 for truck number, follow next steps. KEY LCD screen Explanation Truck No. key key
"2" key key key
"3" key key
"4" key key key
"5" key key key key ENTER key t1 t1 A t2 t2 A t2 B t3 t3 1 t4 t4 1 t4 2 t5 t5 1 t5 2 t5 3 t1: first character First character is A t2: second character. Second character is B. t3: third character. Third character is 1 t4: fourth character Fourth character is 2 t5: fifth character. Fifth character is 3. Save the truck number Exit to weighing mode 9.Error Message and Trouble Shooting
(1) Normal Mode RFErr Reason for error When RW-2601P can't communicate with RW-P in 5 seconds When RW-P has any problem. Treatment After check F12,F13, Turn off and then on. Err 06 Reason Error in printer connection Check the printer connector If there is no problem with printer connector, call your CAS dealer. Trouble shooting Err 08 Reason ZERO or TARE key does not work because weight is not stable. When the weight is stable press the ZERO or TARE key. Trouble shooting Err 09 Reason The weight is beyond ZERO key range. Press the ZERO key within ZERO key range. Trouble shooting Err 13 Reason The zero range deviates from the set range. Trouble shooting Confirm that there is nothing on the weighing platform. If there is nothing on the platform, do calibration in CAL mode. Over Reason Weight is exceed maximum capacity of the scale. Do not exceed the weight limit. If the load cell is damaged, the load cell should be replaced. Trouble shooting
(2) CAL MODE Err 21 Reason The resolution is set to be exceeded the limit 1/30,000. Lower the resolution. The resolution = Maximum weight/one division Modify the maximum weight in CAL1 or modify the division in CAL2 so that the resolution Trouble shooting should be below 1/30,000. Err 22 Reason The weight for span calibration is set to be lower than 10 % of the maximum capacity of the scale. Trouble shooting Set the weight for span calibration in CAL3 to be more than 10% of the maximum capacity. Err 23 Reason The weight for span calibration is set to be exceeded 100 % of the maximum capacity of the scale. Set the weight for span calibration to be within the maximum capacity of the scale in CAL 1. Trouble shooting Notice : Specifications are subject to change for improvement without notice.