CASTLES TECHNOLOGY MP200 Mobile POS Book 2 User Manual Confidential Version 2.1 Feb 2015 Castles Technology Co., Ltd. 2F, No. 205, Sec. 3, Beixin Rd., XindianDistrict, New Taipei City 23143, Taiwan R.O.C. http://www.castech.com.tw WARNING Information in this document is subject to change without prior notice. No part of this publication may be reproduced, transmitted, stored in a retrieval system, nor translated into any human or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written permission of Castles Technology Co., Ltd. All trademarks mentioned are proprietary of their respective owners. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 2 Revision History Version Date Descriptions 1.0 Sep 10, 2014 Initial creation. 1. Add Key Injection on System Menu page 2. UI arrangement on SYSTEM INFO page 2.0 Dec 19, 2014 3. Add BT DIRECT ACCESS, Halt Timeout, PWM Auto, PWM Mode, PWM Time on SYS SETTINGS page 4. UI arrangement on Test Utility page 1. Add the description of Environment. 2.1 Feb 12, 2015 2. Add the description of Power. 3. Add the UL caution of battery. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 3 Contents 1. Introduction .................................................................................................................. 6 2. Hardware Setup ............................................................................................................ 7 2.1. Parts of the Surface ............................................................................................. 7 2.2. Environment ........................................................................................................ 9 2.3. Power .................................................................................................................. 9 3. Basic Operation ......................................................................................................... 10 3.1. Program Manager .............................................................................................. 10 3.2. Download AP ..................................................................................................... 12 3.3. System Info........................................................................................................ 13 3.4. Memory Status .................................................................................................. 14 3.5. System Settings ................................................................................................. 15 3.6. Test Utility .......................................................................................................... 18 3.7. Factory Reset .................................................................................................... 20 3.8. Power Off .......................................................................................................... 21 3.9. Function Key Password Change ........................................................................ 22 3.10. Share Object Management ................................................................................ 23 3.11. Castles TMS ...................................................................................................... 24 3.12. Font Mng ........................................................................................................... 25 3.13. Debug Tools ...................................................................................................... 26 3.14. ULD Key Hash ................................................................................................... 27 3.15. Plug-in Mng ....................................................................................................... 28 3.16. Key Injection ...................................................................................................... 29 4. Secure File Loading ................................................................................................... 30 4.1. ULD Key System ............................................................................................... 30 4.1.1. ULD Manufacturer Key ........................................................................... 30 4.1.2. ULD User Key ........................................................................................ 32 4.1.3. Key Change ........................................................................................... 32 4.2. File Signing ........................................................................................................ 33 4.2.1. Signing Kernel Module ........................................................................... 33 4.2.2. Signing User Files .................................................................................. 35 4.3. File Loading ....................................................................................................... 39 4.3.1. Download by User Loader ...................................................................... 39 4.4. Changing ULD User Key.................................................................................... 42 Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 4 5. Font Management ...................................................................................................... 49 5.1. Loading New Font.............................................................................................. 49 5.2. Custom Font ...................................................................................................... 52 5.3. Using TrueType Font (TTF) ............................................................................... 60 6. FCC Warning .............................................................................................................. 62 FCC Caution ................................................................................................................ 62 RF Exposure Warning.................................................................................................. 62 Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 5 1. Introduction This document provides a guideline on operating and configuring Castles MP200 Mobile POS. The scope of this document includes setting up the terminal, basic operation, application life cycle, and some advance features. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 6 2. Hardware Setup 2.1. Parts of the Surface Front Side 1 2 3 4 5 6 7 8 9 10 MP200 1. LCD Display (Mono Color) 2. Keyboard 3. Cancel Key 6. Power Key 7. Up Key 8. Down Key 4. 0 / Funtion Key 9. OK / Enter Key 5. Contactless Card Landing 10. Clear Key Zone Enter Key Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 7 Rear Side 11 11. Machines Label Up Side bottom Side 12 13 12. MSR 13. SCR Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 8 Side 14 15 14. Power LED (Charging: Orange light, Fully charged: Green light) 15. Micro USB Socket 2.2. Environment Operating Temperature : 0C to 50C Storage Temperature : -20C to 70C Operating Humidity : 5% to 90% non-condensing Storage Humidity : 5% to 95% non-condensing 2.3. Power Input : 5V, 1A Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 9 3. Basic Operation 3.1. Program Manager Upon power on, terminal will enter Program Manager if not default application selected. All user applications are list in Program Manager. User may select an application and run the application or view the application info, delete the application or set to default run upon power on. User may enter System Menu to configure terminal settings. Program Manager Program Manager
-----------01/02 1.App1 2.App2 0:Download Press [0] button to enter System Menu. Press [1] button to toggle default application selection. Press [2] button to delete application. Press [3] button to view application info. Press [OK] button to run application. Press [] or [] to select application. System Menu Page 1 System Menu 1.Download AP 2.System Info 3.Memory Status 4.Sys Settings 5.Test Utility 6.Factory Reset 7.Power Off Press [] button to page 2. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 10 Page 2 System Menu 1.FK PWD Change 2.Share obj Mng 3.Castles TMS 4.Font Mng 5.Debug Tools 6.ULD KEY HASH 7.Plug-in Mng Press [] button to page 1. Press [] button to page 3. System Menu 1.Key Injection Page 3 Press [] button to page 2. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 11 3.2. Download AP Download user application or kernel modules firmware. System Menu System Menu 1.Download AP 2.System Info 3.Memory Status 4.Sys Settings 5.Test Utility 6.Factory Reset 7.Power Off Press [1] button to enter Download AP menu. Download AP Menu Download EX 1.RS232 or USB 2.USB Disk 3.SD Card Select DW Source Select download source:
Press [1] button to select source as RS232 or USB connection and enter ULD download mode. Press [2] button to select source as USB disk. Press [3] button to select source as SD card. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 12 3.3. System Info View kernel module firmware information. System Menu System Menu 1.Download AP 2.System Info 3.Memory Status 4.Sys Settings 5.Test Utility 6.Factory Reset 7.Power Off Press [2] button to enter System Info menu. System Info Menu Page 1 Page 2 Page 3 SYSTEM INFO
---Kernel Ver---
BIOS :VR0010 SULD :VRF810 LINUXKNL :VR0019 ROOTFS :VR9201 SYSTEM INFO
--- KO Ver ---
SECURITY :VR0025 KMS :VR0024 DRV :VR0039 USB : N/A SAM :VR0028 CL :VR0018 Press [] button to next page. SYSTEM INFO
--- KO Ver2 ---
SC :VR0011 Page 4 Page 5 Page 6 SYSTEM INFO
--- SO Ver ---
UART :VR0014 USBH :VR0011 MODEM :VR0014 ETHERNET :VR0029 FONT :VR0025 LCD :VR0034 SYSTEM INFO
--- SO Ver2 ---
PRT :VR0020 RTC :VR0013 ULDPM :VR0022 PPP MODEM:VR0026 KMS :VR0022 FS :VR0015 Page 8 Page 9 SYSTEM INFO
--- HWM Ver ---
CRDL/ETHE:ONCHIP CLM-MP : N/A
--- AP Ver ---
ULDPM :VR0026 SYSTEM INFO HUSB ID:0CA6A050 CUSBID : N/A
--Factory S/N---
FFFFFFFFFFFFFFFF SYSTEM INFO
--- SO Ver3 ---
GSM :VR0018 BARCODE :VR0013 TMS :VR0013 TLS :VR0011 CLVW :VR0018 CTOSAPI :VR9029 Page 10 SYSTEM INFO
--EXT SO Ver P.1--
CACLMDL :VRg103 CACLENTRY :VRg103 CAMPP :VR0302 CAVPW :VR0014 CAEMVL2 :VR9113 CAEMVL2AP :VR0005 Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 13 3.4. Memory Status View terminal flash memory and RAM information. System Menu System Menu 1.Download AP 2.System Info 3.Memory Status 4.Sys Settings 5.Test Utility 6.Factory Reset 7.Power Off Press [3] button to enter Memory Status menu. Memory Status Menu MEMORY STATUS
--FLASH Memory--
Total: 130688KB Used : 96648KB
--SDRAM Memory--
Total: 65408KB Used : 32148KB Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 14 3.5. System Settings View or change terminal system settings. Descriptions Setting Key Sound Enable (Y) or disable (N) the beep sound when pressing any key. Exec DFLT AP Enable (Y) or disable (N) execution of default selected application. USB CDC Mode Enable (Y) or disable (N) USB CDC mode. FunKey PWD Enable (Y) or disable (N) password protection to access function key (0 ~ 3) in Program Manager. PMEnter PWD Enable (Y) or disable (N) password protection to enter Program Manager. SET USB Host Enable (Y) or disable (N) USB host mode. Base USB CDC Enable (Y) or disable (N) USB CDC mode in base unit. [Portable model only]
List SHR Lib Enable (Y) or disable (N) to list all shared libraries Key MNG Mode
<TBC>
in Program Manager. BAT Threshld Battery charging threshold value. [Portable model only]
Null Cradle Enable (Y) if base is Type A cradle. [Portable model only]
Debug Mode Enable (Y) or disable (N) console debug mode. Debug Port Serial port for console debug. Mobil AutoON Enable (Y) or disable (N) to auto turn on GSM module after start up the terminal. Bklit Auto Off Enable (Y) or disable (N) Auto Off LCD Backlight Bklit Off Time Threshold of Auto Off LCD Backlight PWR KEY OFF Power key function, power off (Y) or reboot(N) GDB Mode Enable (Y) or disable (N) GDB mode. GDB Timeout GDB connection timeout. GDB Channel GDB connection channel. ETHER IP/PORT GDB Ethernet connection setting. RTC Time Zone Set Time Zone of Real Time Clock. NTP Enable Enable (Y) or disable (N) Network Time Protocol. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 15 NTP Update Freq Frequency of Network Time Protocol updating. BT DIRECT ACCESS Enable (Y) or disable (N) Bluetooth direct access mode. Halt Timeout Set timeout for AP to back to Program Manager whenever AP is in halt state. PWM Auto PWM Mode Enable (Y) or disable (N) power saving mode. Select (STB) standby mode or (SLP) sleep mode for power saving mode. PWM Time Set time period by which to make terminal getting into power saving mode from idle state. System Menu System Menu 1.Download AP 2.System Info 3.Memory Status 4.Sys Settings 5.Test Utility 6.Factory Reset 7.Power Off Press [4] button to enter System Settings menu. System Settings Menu Page 1 Page 2 SYS SETTINGS Key Sound : Y Exec DFLT AP : Y
-Default AP Name USB CDC Mode : Y FunKeyPWD : N PMEnterPWD : N 2: Next Page SYS SETTINGS SET USB Host : N Base USB CDC : X List SHR Lib : N Key MNG Mode : 0 Bat Threshld : X Null Cradle : X 1: Prev 2: Next Page 3 Page 4 SYS SETTINGS Debug Mode : N Debug Port : X Mobil AutoON : N Bklit Auto Off : N Bklit Off Time : X PWR KEY OFF : N 1: Prev 2: Next SYS SETTINGS GDB Mode : N GDB Timeout : X GDB Channel : X ETHER IP/PORT 1: Prev 2: Next Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 16 Page 5 Page 6 SYS SETTINGS RTC Time Zon :GMT NTP Enable : N NTP Update F : X 1: Prev 2: Next SYS SETTINGS BT DIRECT ACCESS :X Halt Timeout :999 PWM Auto : N PWM Mode : X PWM Time : X 1: Prev Page Press [] or [] button to select setting. Press [OK] button to change the setting value. Press [] button to toggle Y N Y. Press [1] button to previous page. Press [2] button to next page. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 17 3.6. Test Utility Perform terminal hardware components diagnosis. System Menu System Menu 1.Download AP 2.System Info 3.Memory Status 4.Sys Settings 5.Test Utility 6.Factory Reset 7.Power Off Press [5] button to enter Test Utility menu. Test Utility Menu Page 1 Main Menu 9122 1.LCD 2.KBD 3.FLASH 4.SCM 5.Light 6.MSR 7.LED 8.RTC 9.FONT 10.USB 11.BT 12.Power
-> 1/2 Press [1] and [OK] to diagnose LCD. Press [2] and [OK] to diagnose keyboard. Press [3] and [OK] to diagnose flash memory. Press [4] and [OK] to diagnose smart card module. Press [5] and [OK] to diagnose backlight. Press [6] and [OK] to diagnose magnetic stripe card reader. Press [7] and [OK] to diagnose LED. Press [8] and [OK] to diagnose RTC. Press [9] and [OK] to check FONT file in MP200. Press [10] and [OK] to diagnose USB. Press [11] and [OK] to check Bluetooth chip address and name. Press [12] and [OK] to test functionality of power saving. Press [] button to page 2. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 18 Page 2 Main Menu 9122 13.CL 14.WiFi
-> 2/2 Press [13] and [OK] to diagnose contactless card reader. Press [14] and [OK] to diagnose WiFi. Press [] button to page 1. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 19 3.7. Factory Reset Perform factory reset, all user application, fonts and data will be deleted. System Menu System Menu 1.Download AP 2.System Info 3.Memory Status 4.Sys Settings 5.Test Utility 6.Factory Reset 7.Power Off Press [6] button to enter Factory Reset menu. Factory Reset Menu Factory Reset OK to reset ?
Press [OK] button to perform factory reset. Factory Reset Password :
****
Enter factory reset password. Default password: 8418 Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 20 3.8. Power Off Power off terminal. System Menu System Menu 1.Download AP 2.System Info 3.Memory Status 4.Sys Settings 5.Test Utility 6.Factory Reset 7.Power Off Press [7] button to power off terminal. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 21 3.9. Function Key Password Change Change function key access password. System Menu (Page 2) System Menu 1.FK PWD Change 2.Share obj Mng 3.Castles TMS 4.Font Mng 5.Debug Tools 6.ULD KEY HASH 7.Plug-in Mng Press [1] button to enter FunKey Password menu. FunKey Password Menu FunKey Password Enter Password:
****
Enter current password. (Default password is "0000") FunKey Password New Password:
****
Confirm Password
****
Enter new password. Enter new password again to confirm. FunKey Password New Password:
****
Confirm Password
****
PWD Changed OK Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 22 3.10. Share Object Management View share object in terminal. System Menu (Page 2) System Menu 1.FK PWD Change 2.Share obj Mng 3.Castles TMS 4.Font Mng 5.Debug Tools 6.ULD KEY HASH 7.Plug-in Mng Press [2] button to enter Share Object Management menu. Share Object Management Menu Share objMng 1.Share LIB 2.Share File Press [1] button to view shared library. Press [2] button to view shared file. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 23 3.11. Castles TMS Connect to TMS (Terminal Management Software) server, set or delete TMS configuration. System Menu (Page 2) System Menu 1.FK PWD Change 2.Share obj Mng 3.Castles TMS 4.Font Mng 5.Debug Tools 6.ULD KEY HASH 7.Plug-in Mng Press [3] button to enter Castles TMS menu. Castles TMS Menu CASTLES TMS 1.Connect Server 2.SetConfig 3.DelConfig Press [1] button to connect to TMS server. Press [2] button to set TMS configuration. Press [3] button to delete TMS configuration. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 24 3.12. Font Mng View Font Management. System Menu (Page 2) System Menu 1.FK PWD Change 2.Share obj Mng 3.Castles TMS 4.Font Mng 5.Debug Tools 6.ULD KEY HASH 7.Plug-in Mng Press [4] button to view Font Management. FontManagment Font Mng 1.FNT File 2.TTF File Press [1] button to view FNT Font list. Press [2] button to view TTF Font list. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 25 3.13. Debug Tools Perform the Debug Tools. System Menu (Page 2) System Menu 1.FK PWD Change 2.Share obj Mng 3.Castles TMS 4.Font Mng 5.Debug Tools 6.ULD KEY HASH 7.Plug-in Mng Press [5] go to the Debug Tools Menu. Debug Tools Debug Tools 1.CoreDump 2.Debug Log Press [1] go get the Core Dump error from terminal. Press [2] go to the Debug Log Menu. Debug Log Debug Log 1.Upload 2.Clean All Press [1] move the Debug Log from the memory of terminal to SD card. Press [2] clean all the Debug Log in MP200. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 26 3.14. ULD Key Hash View ULD user key hash value. System Menu (Page 2) System Menu 1.FK PWD Change 2.Share obj Mng 3.Castles TMS 4.Font Mng 5.Debug Tools 6.ULD KEY HASH 7.Plug-in Mng Press [6] button to view hash value. USER ENV KEY DA9C91FE668DF4B6D637 CDBCCEC201444AA2C7FF USER SIGN KEY D52F36A1B569B5ABBA4F EAEFB34BEC000101D58C Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 27 3.15. Plug-in Mng View Plug-in Management. System Menu (Page 2) System Menu 1.FK PWD Change 2.Share obj Mng 3.Castles TMS 4.Font Mng 5.Debug Tools 6.ULD KEY HASH 7.Plug-in Mng Press [7] button to view Plug-in Management. Plug-in Mng 1.Info 2.Del Press [] or []button to select item. Press [1] button to get item information. Press [2] button to delete item. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 28 3.16. Key Injection View Key Injection. System Menu (Page 3) System Menu 1.Key Injection Press [1] button to view Key Injection. Select COM Port
------------01/03 1. COM 1 2. COM 2 3. USB OK:Select X:Exit Press [1] to select COM 1. Press [2] to select COM 2. Press [3] to select USB. Press [OK] to set port. Press [X] to exit. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 29 4. Secure File Loading Castles implemented an interface in terminal named User Loader(ULD) to provide secure file loading to system memory. Loading of user application, kernel firmware, font and others must use User Loader. The loading process is secure by signing the files using ULD Key System. 4.1. ULD Key System The ULD Key System uses two key sets for securely managing the kernel updating and application downloading. Each key set contains two RSA key pairs. One is used for key encryption and the other is used for signature. These two key sets are specified as below:
ULD Manufacturer Key Set ULD Manufacturer Key Encryption Key (RSA) ULD Manufacturer Signature Key (RSA) ULD User Key Set ULD User Key Encryption Key (RSA) ULD User Signature Key (RSA) For MP200, the RSA key length is 2048bits. 4.1.1. ULD Manufacturer Key The system consists of several kernel modules. These kernel modules are provided by the Manufacturer, and released in CAP format file with encryption and signing via ULD Manufacturer Keys. The ULD Manufacturer keys are managed and maintained by the manufacturer. The manufacturer uses these keys to generate kernel CAP files for updating the system. However, the system is not permitted to be updated with these kernel CAP files directly generated by the manufacturer. This is because only the user can have the privilege to decide whether the system is to be updated. Therefore, before system Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 30 updating, the kernel CAP files must be signed via ULD User Key to get the user permission. For simple expression, we call the kernel CAP files generated by the manufacturer as unsigned kernel CAP(s) and call the kernel CAP files signed by the user later as signed kenel CAP(s). Notes:
1. The kernel modules are encrypted by a random-generated 3DES key, which is retrieved from the Key Encryption Block of the CAP by ULD Manufacturer Key Encryption Key, not directly encrypted by ULD RSA Key. 2. The sign action via ULD User Keys actually is done by the second encryption. The second encryption is done by using the random-
generated 3DES key, which is encrypted by ULD User Key Encryption Key, to perform Triple DES encryption again on the cipher data segment of the kernel CAP files. This ensures that the system cannot retrieve the correct data from the kernel CAPs without the user permission. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 31 CAP GeneratorKernel ModuleULD Manufacturer KeysUnsigned Kernel CAPsUnsigned Kernel CAPsCAP Signing ToolSigned Kernel CAPsULD User Keys 4.1.2. ULD User Key ULD User Key are used to encrypt and sign the user/shared applications. In addition, they are as goalkeepers to prevent the system updating without user permission. This is done by the kernel CAPs which are encrypted and signed by the manufacturer having to perform the signed action via ULD User Keys. Notes: Applications are encrypted by a random-generated 3DES key, which is retrieved from the Key Encryption Block of the CAP by ULD User Key Encryption Key, not directly encrypted by ULD RSA Key. 4.1.3. Key Change The ULD RSA Keys are able to be changed. The system uses a special CAP file, KEY CAP, for the manufacturer and user to change their own keys. The KEY CAP contains a new set of ULD keys (Key Encryption Key and Signature Key). These new keys are encrypted and signed via the original keys. In other words, if the user would like to change the ULD User Keys, they have to use their original ULD User Keys with the new ULD User Keys to generate a KEY CAP. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 32 ApplicationApplication CAPsULD User KeysCAP GeneratorKey CAP GeneratorOriginal ULD Manufacturer/User KeysNew ULD Manufacturer/User KeysUser KEY CAP 4.2. File Signing 4.2.1. Signing Kernel Module Castles will release new version of kernel module in unsigned form. This files required to sign with ULD User Key before it can load to terminal. Castles Technology provideds a tool named CAP Signing Tool to perform this task. The CAP Signing Tool is located at:
C:\Program Files\Castles\MP200\tools\Signing Tool Run CAP Signing Tool
(MP200) Insert Key Card and select smart card reader Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 33 Enter Key Card PIN CAP Signing Tool is ready, press Select MCI File button to browse the file. Output file will be located in signed folder. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 34 4.2.2. Signing User Files Following files are required to sign before load to terminal. This is to ensure the application data and codes confidential and integrity. The output file will be CAP file which is file format defined by Castles. User application User application data files User application library Font file Share library Share files System setting Key CAP (Manufacturer ULD Key Set) Castles Technology provided a tool named CAP Generator to perform this task. The CAP Generator is located at:
C:\Program Files\Castles\MP200\tools\CAPG (KeyCard) Run CAP Generator Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 35 Insert Key Card and select smart card reader Enter Key Card PIN Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 36 CAP Generator is ready, select the correct Type from the list. Press Step 1: Select AP Executable File to select file to sign. This is valid for all the files to sign. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 37 Enter file details and press Step 2: Sign Application to sign the file. This is valid for all the files to sign. The output file will be in a set. A mci file with one or more CAP files.CAP file contents the signed file binaries, where MCI file contents the list of CAP files. App.CAP App.mci Note: If user would like to load multiple set of signed file, create a new file with extension of mmci. Then put the mmci file contents with the list of mci file. MultiApp.mmci Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 38 4.3. File Loading There are several ways of loading file to MP200. Download by User Loader Download by user application Download by Castles TMS User Loader is a tool provided by Castles Technology. Its the formal way to download file to terminal. User may implement their own ways of updating application or files using CTOS API provided, CTOS_UpdateFromMMCI(). Castles TMS (CTMS or CASTLES Terminal Management System) is provided by Castles Technology. Its use to perform remote download via Ethernet, GPRS/UMTS or modem. 4.3.1. Download by User Loader The User Loader works for MP200. The Loader is located at:
C:\Program Files\Castles\MP200\tools\Loader Run User Loader Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 39 Select COM port Browse and select mci file or mmci file Setup terminal to enter download mode Press [0] button in Program Manager (PM) Press [1] button to select 1. Download AP Press [1] button again to select download via RS232 or USB Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 40 Press Download button to start. Note: To download using USB cable, terminal must enable CDC mode. Set USB CDC Mode to Y. SYS SETTINGS Key Sound : Y Exec DFLT AP: Y
-AP Name USB CDC Mode: Y FunKeyPWD : N PMEnterPWD : N 2: Next Page Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 41 4.4. Changing ULD User Key User may change their ULD User Key Set stored in Key Card. Castles Technology provided a tool named Secure Key Generator to perform this task. Run Secure Key Generator Insert Key Card and select smart card reader Enter Key Card PIN, default PIN is 1234. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 42 To change Key Card PIN, press Update PIN button. If not, please skip this steps. Enter new PIN, enter new PIN again to confirm, then press [Enter] button to change PIN in Key Card. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 43 To view current key set hash value, goto Option and select key. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 44 To generate new user key set Please generate the RSA key by yourself,thelength of the RSA key set should be 2048 (bits). Copy RSA key components to RSA Key for Kenc in Secure Key Generator. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 45 Generate second RSA key set for Signature. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 46 Click [Get Hash] button to calculate the hash value for key sets. Please copy down all the values into a text file and keep in a safe place. You will need this if you need to create duplicate Key Card. To generate the key CAP for the newly generated user key set, press [Make Key CAP File] button. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 47 The output file will be located in the Secure Key Generator folder. SecureKeyGenerator key.mci key.cap To update the newly generated key set to Key Card, press [Save to Card]
button to write the key set to Key Card. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 48 5. Font Management 5.1. Loading New Font Run FontManager.exe Located at C:\Program Files\Castles\Font Manager Select font to download Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 49 Press [Setting] button to configure terminal type. Select VEGA5000, press [Save] button to save and return font manager. Press [Generate] to create the font file. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 50 Output file Font.FNT will be located at sub-directory named Font in Font Manager folder. Font Manager Font Font.FNT Sign the file using CAP Generator, the type must set to 11 Linux Font. Lastly, download the signed file (CAP file) to terminal using Loader. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 51 5.2. Custom Font User may create font they preferred for displaying or printing on terminal. There are two zone defined:
Zone 0x00 ~ 0x7F ASCII characters, you may replace with the font type preferred or your own language character set. Zone 0x80 ~ 0xFF Free to use, you may use for symbols. Following steps demonstrate how to create a 12x24 font. Run GLCD Font Creator Select [File] [New Font] [Import An Existing System Font]
Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 52 Select the font needed, simply choose a font size. The final value of font size should be determine by the minimum pixel width. You may need to repeat this steps few times to find the best fit font size. Set the import range from 0 to 127. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 53 Check the minimum pixel width and height. If the pixel width of the font size is larger than expected, then you have to repeat the previous steps to import font with smaller size. Use the following buttons to adjust the font size to match with expected font size. Add columnonrigh Removecolum nonleft t Removecolumn onright Remove row on bottom Add row on bottom Remove row on top Add column on left Add row on top Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 54 After adjust font size, select [File] [Export for MicroElektronika]. Select output format as [mikroC]. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 55 Remove comment // Code for char from offset 0x00 to 0x1F. Remove empty line if found. Then click [Save] button to save to file. Remove Remove Remove Remove Run Font Manager Tool. Click [Setting] button Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 56 Enter the file name, font id, and select the size. Click [Create] button, and select the C file previously created using GLCD Font Generator. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 57 Select [Font Manager] tab and tick the newly createdfont, and press
[Generate] button to export to FNT file. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 58 Use CAP Generator to conver the FNT file to CAP. Set type to [11 Linux Font], press [Step 1] button select the FNT file. Then press [Step 2] to generate CAP file. Download the font CAP file to terminal. In terminal application, add following code to display message using the newly created font. CTOS_LanguageConfig(0xA000,d_FONT_12x24,0,d_FALSE);
CTOS_LanguageLCDSelectASCII(0xA000);
CTOS_LCDTPrintXY(1, 1, "ABCDEFGH");
Or print message using the newly created font. CTOS_LanguagePrinterSelectASCII(0xA000);
CTOS_PrinterPutString("ABCDEFGH");
Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 59 5.3. Using TrueType Font (TTF) TrueType Font (TTF) is supported in MP200. You may download the TrueType font preferred to terminal for displaying or printing. Following steps demonstrate how to use Cooper Black TrueType font. Copy the TTF file needed to a empty folder. TTF COOPBL.TTF Use CAP Generator to conver the TTF file to CAP. Set type to [11 Linux Font], press [Step 1] button select the TTF file. Then press [Step 2] to generate CAP file. Download the font CAP file to terminal. Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 60 In terminal application, add following code to display message using the newly added font. CTOS_LCDTTFSelect("COOPBL.TTF", 0);
CTOS_LCDFontSelectMode(d_FONT_TTF_MODE);
CTOS_LCDTSelectFontSize(0x203C); // 32x60 CTOS_LCDTClearDisplay();
CTOS_LCDTPrintXY(1, 1, "Hello World");
Or print message using the newly added font. CTOS_PrinterTTFSelect("COOPBL.TTF", 0);
CTOS_PrinterFontSelectMode(d_FONT_TTF_MODE);
CTOS_LanguagePrinterFontSize(0x203C, 0, 0); // 32x60 CTOS_PrinterPutString("Hello World");
Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 61 6. FCC Warning Federal Communication Commission interference statement. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. FCC Caution This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference and
(2) this device must accept any interference received, including interference that may cause undesired operation RF Exposure Warning The equipment complies with RF exposure limits set forth for an uncontrolled environment. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. This device and its antenna(s) must not be co-located or operated in conjunction with any antenna or transmitter not described under this FCC ID, except in accordance with FCC multi-transmitter RF exposure procedures.
~ END ~
Castles Technology Co., Ltd. Confidential All Right Reserved. Pg. 62