W Power Station portable Wi-Fi User Manual Model: SR0KW3L-SG1-US, PS300-US, PW601-300, XP2W300USCA, HWBG200 Content
. Parameters
. Safety guidelines
. Warning
. Discard
. Guideline for users
. Product overview
. LCD screen
. Use
. AC charging
. PV charging
. Car charging
. Constant power
. APP
. EPS function
. FAQs (Frequently Asked Questions)
. Error messages & solutions
. Whats in the box
. Maintenance
. Disclaimer pure sine-wave, total W (peak W), -V~, Hz/Hz, .A
-V~, Hz/Hz, W Max., .A
(lbs)
.kg xxmm (.x.x.in)
.Wh .V , Ah supported
. Parameters General Net weight Dimension Battery capacity Wi-Fi Output
(UK/EU/FR/AU/ZA) AC socket (Inverter mode) AC socket (Bypass mode)
(US) pure sine-wave, total W (peak W), -V~, Hz, A AC socket (Inverter mode)
-V~, Hz, W Max., A AC socket (Bypass mode) V .A, W Max. USB-A/A
/// A, V .A, W Max. USB-C/C USB-C+C
/V A, V .A, V A, V .A, W Max. Car charger
.V AW Max.
* Inverter mode: the output AC power comes from the battery, not the grid.
* Bypass mode: the output AC power comes from the grid, not the battery. Input
(UK/EU/FR/AU/ZA) AC input power AC input voltage
(US) AC input power AC input voltage PV charge Car charging input Input charging AC charging power PV charging input Car charging input AC+PV charging power W Max., A
-V~, Hz W Max., -V A V battery supported, A by default W Max., A
-V~, Hz/Hz W Max. W Max. W Max. W Max. lithium iron phosphate battery (LiFePO) cycles over temperature protection, low temperature protection, over discharge protection, over charge protection, over load protection, short circuit protection, over current protection Battery Cell Type Life cycle Protection type
*Test conditions% DOD, .C charge & .C discharge at +. Operating temperature Optimal operating temperature Discharge temperature range Charge temperature range Storage ambient temperature
*Whether the product can be charged or discharged is subject to the actual battery pack temperature.
~ (F~F)
-~ (-F~F)
~ (F~F)
-~~ preferred [-F~F(F~F preferred)]
. Safety guidelines
. Warning
. Do not let a working power station be close to the heat source, such as re or heater. Do not make power station contact with any liquid. Do not use power station in a strong electrostatic or strong magnetic eld environment. Do not disassemble power station in any way or pierce it with a sharp object. Do not short power station by wire or other metal objects. It is forbidden to step on, sit or climb on this product. Do not use ingenuine parts or accessories. For part or accessory replacement, please visit ocial sales channel for purchase information. When using power station, please follow the operating temperature dened in this user manual strictly. If the temperature is too high, battery may catch re or even explode. If the temperature is too low, power station performance will be seriously impaired, even normal use will be impacted. Do not stack heavy objects on power station. Do not stop the fan by force or expose power station in an unventilated or dusty environment when it is working. Please avoid collision, drop, and violent vibration. If severe impact happens, shut down the power supply immediately. Please x power station rmly during transportation to avoid vibration and impact. If power station falls into water accidentally, place it in a safe and wide area, and keep yourself away from it until its dry. Dried product shall not be used again. Dispose it properly according to chapter . in this user manual. If power station is on re, please use re extinguishing equipment in the recommended order: water or water mist, sand, re blanket, dry powder, dioxide carbon re extinguisher. If there is dirt, use a dry cloth to wipe it. Place power station carefully to prevent damage. If power station is tipped over and seriously damaged, turn o power station immediately and place the battery in a spacious place and keep it away from ammable materials and people, and scrap it in accordance with the requirements of local laws and regulations. Keep power station out of the reach of children and pets. Keep power station in a dry and ventilated place. In humid environment (seaside, water, etc.), it is recommended to equip power station with moisture-proof bag. If water is found inside product, do not use/start it again. Please take countermeasures to prevent electric shock before touching power station. Put it in a safe and waterproof open area, and contact customer service immediately. It is not recommended to use power station to supply power for safety-related emergency medical equipment, including but not limited to medical grade breathing machine (hospital version CPAP: Continuous Positive Airway Pressure), articial lung (ECMO, Extracorporeal Membrane Oxygenation). It can be used to supply power for home version CPAP at home and does not require continuous professional monitoring. Please follow your doctor's advice and consult the manufacturer for any restrictions on the use of the device. For general medical equipment, please pay attention to the power condition to ensure that power does not run out. Power supplies will inevitably generate electromagnetic elds when it is in use, which might aect the implantable medical device or normal operation of personal medical device, such as pacemaker devices, cochlear implants, hearing AIDS, debrillators, etc. If any of these medical devices are used, please consult the manufacturer about the restrictions on the use to ensure that power station is operated at a safe distance from implanted medical devices such as pacemakers, cochlear implants, hearing AIDS, debrillators, etc. When the power station is connected to a refrigerator, it may automatically shut down because of the power uctuation property of the refrigerator. When connecting the power supply to a refrigerator that stores medicine, vaccines or other valuable items, it is recommended to set the AC output to "Never o" in the APP, so as to ensure continuous power. Users should pay attention to power consumption. During the push-pull movement of this product, it is forbidden to put other items on this product. Discard
. Conditions permitting, be sure to discharge the battery completely, and then put power station in the specied battery recycling bin. Power station contains batteries, which are dangerous. It is strictly prohibited to discard them in ordinary dust bins. For details, follow local laws and regulations on battery recycling and disposal. If the battery cannot be discharged completely due to product failure, do not discard the battery directly in the battery recycling bin. Contact a professional battery recycling company for further disposal. The battery will not start after over discharge. Please dispose it as discarded. Guideline for users
. Product overview LED light button Car charge output ON/OFF button USB-A output port x LED light LCD Input Output AC output button USB-C output port x AC output socket UK US EU AU FR ZA Ventilation opening Ventilation opening
. Use Input Output Short press to turn on Long press to turn o AC input socket Solar / car charge input
. LCD screen Remaining battery percentage Remaining charge /
discharge time Input power Input Output Wi-Fi connection status Bluetooth Output power AC output Error code On and o Press the main power switch to turn on the device, then the screen will be lit and the main power indicator light will light up. When this product lasts for minutes without any operation, the LCD display will be automatically extinguished. When this product is plugged in and unplugged from mains, pv, car charger or key operation, the LCD display will be lit up automatically. To turn on or o the LCD display, press the main power switch. Press and hold the main power switch will turn o power station. In the normal mode (the power is above %), the default standby time of this product is hours; when the AC output switch is not turned on, and there is no charge or discharge for hours, the product will automatically shut down, and the standby time can be Set it on the APP; when the power is % or below, the product will be forced to enter the low power mode. In the case of no charge or discharge, the product will adjust the standby time according to the power and automatically shut down. In normal mode, long press the LED light button to exit the automatic shutdown setting, and the battery icon on the screen will ash. Long press again to enter the automatic shutdown setting, and the battery icon does not ash. (The automatic shutdown setting is to protect the battery from low power, exiting this setting may damage the battery life, please use it with caution.) LED lights Short press the LED light button to switch four gears, which are low light, medium light, high light, SOS and light o. Battery capacity: When power station is being charged, SOC icon will icker. Wi-Fi connection status: When wi reset, wi icon will ash for s, wi icon light up when wi link, wi icon go out when wi disconnect. Bluetooth connection status: The Bluetooth icon lights up when this product is matched wirelessly. The Bluetooth icon lights up when the Bluetooth link is successful. Bluetooth icon goes out when Bluetooth is disconnected.
* Please refer to clause for more details regarding error message. LED light button Input Output Note: When no AC input, long press the above AC output button, you can switch the AC o-grid output frequency ( / ), long press s to switch, the AC output icon will ash times after successful switching. AC charging When the product is turned on, the default fast charging mode is working. If your product has a wi function, you can control the recharge rate through the APP. The V DC output is turned on by default when the main power supply is turned on. V DC output Input Output USB output USB output is enabled by default after the main power switch is turned on. Short press AC output power switch FR ZA US EU AU UK AC output After ensuring that the main power is turned on, short press the AC output power switch to turn on the AC output. Short press the AC output power switch again to turn it o. The default standby time of the AC output port is hour. After hour without any load on the AC output port of this product, the AC output power will be automatically turned o. In normal mode, long press the LED light button, the AC output power switch can exit the automatic shutdown setting, and the battery icon on the screen will ash. Long press again, the AC output power switch enters the automatic shutdown setting, and the battery icon does not ash. Long press the LED light button to exit the AC automatic shutdown setting: it is applicable to AC equipment below W and pulse working equipment. When the AC output is not in use, turn it o to save power consumption. In fast charging mode, it takes about minutes to fully charge. AC wire Please use the standard AC cable for charging. AC charging cable should directly plug intoA (or above) wall-mounted socket. We take no responsibilities for any damage caused by using unocial AC charging cable, and other failures to follow instructions. PV charging
*Solar charging cable (DC) Please follow the user manual to connect the solar panels. Before connecting the solar panel, check whether its output voltage is within power station specications to avoid damage to power station.
*The interface of this product is DC. If you need an adapter cable from MC to DC, please purchase it yourself. Charge the power station by solar panel. Car charging
*Car charger cable (DC) Power station can be charged by a car charging port. It should be charged after the car starts, so as to avoid the car battery loss and failure to start. At the same time, ensure good connection between the car charging port and cigarette lighter. We take no responsibilities for any loss caused by improper operation. Constant power
. The constant power output function is enabled by default, which can be turned on or o by App. Constant power output function is more suitable for heater and motor instead of all electrical equipment. It is not suitable for some electrical appliances with voltage protection (such as precision instruments). Constant power output function application is subject to actual testing. APP You can control and view information and data about this product by App. Software download, search for [Smart Life] in the Google App Store or Apple App Store, download the software, register and open it or scan the QR code below to download. For detailed usage of the APP, please refer to the APP Operation Guide. EPS function This product supports the EPS (emergency backup power) function. You connect the power grid and the AC input port of this product through the AC charging cable; Bypass mode (AC power comes from the grid, not the battery); when the grid suddenly loses power, the product can automatically switch to battery power supply mode within mS, at this time it is an inverter mode (AC power comes from the battery, not the grid). This function does not support mS switching. Please do not connect it to devices that require high uninterrupted power supply, such as data servers and workstations, or use it after multiple tests to conrm whether it is compatible, and It is recommended to use only one device during use, and do not use multiple devices at the same time to avoid overload protection of the product. If the device does not operate normally or data is lost due to failure to follow the instructions, our company will not bear the corresponding responsibility. socket electrical appliance UK FR US AU EU ZA
. FAQs (Frequently Asked Questions)
. What kind of battery is used?
Lithium iron phosphate battery (LiFePO). What equipment can be connected to the AC output ports?
The AC output port of the product has high rated power and the highest power, which can supply power for small power household equipment. We suggest conrming the power of the equipment before use to ensure that the sum of the power of all load equipment is lower than the rated power. How to know the supply time?
Time shows in the LCD, which can be referred to for estimation for equipment with stable power consumption. How to know it is charging?
When in charge, the LCD shows remaining charging time. The SOC ickers, and input power is shown. How to clean the unit?
Clean the unit with a dry, soft and clean cloth or tissue. How to store the unit?
Turn it o, and keep it in a dry and ventilated place. Do not expose it close to water. For long-term storage, suggest discharge to % and charge to % every months to extend the service life. Can it be taken on board?
No. Error messages & solutions Icon Fault Description Solution Error code always on Error code always on Error code always on Pressure dierence is too large Battery OTP
(over temperature protection) fault Battery UTP
(under temperature protection) fault Error code always on OCP (over current protection) fault Error code always on Abnormal precharge Automatic recovery after fault clearing;
consecutive locks within a certain period of time, longer recovery time. Shut down, after temperature recovery, rechargeable activation. Remove the over-power device, and it will automatically recover after the fault is cleared; if it is triggered continuously for times within minute, it will be locked, and the recovery time will be prolonged, and it can be recovered by powering on and o again. Power on and o again to clear the fault. Error code always on Error code always on Error code always on Error code always on Battery under voltage fault Abnormal INV battery voltage Grid voltage or frequency fault Abnormal INV BUS voltage Error code always on Abnormal INV output Error code always on INV discharge overload Error code always on Charge overload charging process, Repeated charging failures or failure to charge, please contact customer service. Automatic recovery after the fault is cleared; if it is triggered times within minute, it will be locked, and the recovery time will be extended, and it can be recovered by powering on and o again. The fault is cleared when the grid returns to normal. Automatic recovery after the fault is cleared; if it is triggered times within minute, it will be locked, and the recovery time will be extended, and it can be recovered by powering on and o again. Remove the over-power device, and it will automatically recover after the fault is cleared; if it is triggered continuously for times within minute, it will be locked, and the recovery time will be prolonged, and it can be recovered by Automatic recovery after the fault is cleared; if it is triggered times within minute, it will be locked, and the recovery time will be extended, and it can be powering on and o again. recovered by powering on and o again. If there is a warning occurs during the use of this product, and the warning icon still does not disappear after restarting the device, please stop using it immediately (do not try to charge or discharge). Icon Error code always on Fault Description INV Tz Error code always on INV output short Solution Auto recover after fault is cleared. Fault will be cleared after reboot. After removing the device and restarting, the fault is cleared. turn on and o, Exclude the fan abnormality, contact after sales if still not xed. Auto recover after fault is cleared. Automatic recovery after the fault is cleared; if it is triggered times within minute, it will be locked, and the recovery time will be extended, and it can be recovered by powering on and o again. Automatic recovery after the product heats up. Remove PV charge, auto recover after connecting PV and turn on. Stop PV charging, auto recover after connecting PV and turn on. Turn o output, manual recover after fault is cleared. Removing the PV charging interface will automatically restore it after a certain period of time. Remove the PV charging interface for a certain period of time to automatically recover or check whether the PV output Stop PV. Auto recover after fault is cleared. fuse is disconnected. Turn on and o, Error code always on MOSFET OTP fault Error code always on Fan stop Error code always on Discharge soft start fault Error code always on Charge soft start fault Error code always on Error code always on Error code always on Error code always on Error code always on Error code always on Error code always on MOSFET UTP fault PV hardware OCP fault PV software OCP fault Car charger output/
DC output Over current protection PV output OVP
(over voltage protection) fault PV input voltage over-voltage protection PV OTP fault Abnormal communication The battery voltage is too low. The battery is broken Error code always on or change operation environment. Contact after sales if still not xed. Contact after-sales processing. If none of the above information can solve problem you encounter, please contact the customer service for consultation. Error code always on
. What's in the box Input Output Power station AC cable Car charge cable User manual
. Maintenance It is recommended to use or store power station under ~ ambient temperature. Keep it away from water, heater and metal parts. For long-term storage, charge and discharge every months, i.e. discharge to % then charge to %. For safety, do not store power station with temperature above or below -. If the capacity is lower than %, please charge to %. Long-term storage with serious power shortage will cause irreversible damage to the cell and shorten the service life of the product. If the capacity is seriously insucient and idle time is too long, the product will enter deep sleep mode, and the product can only be used after being charged. Disclaimer The product has a built-in battery management system, which has protections such as overcharge, overdischarge, overcurrent, short circuit, high and low temperature, and abnormal communication. During the use of this product, protection may occur and cause output interruption. Power supply to special equipment, such as medical equipment, server, the indirect loss caused by accidental power failure has nothing to do with the company; all accidents caused by illegal use, self-dismantling, and man-made damage have nothing to do with the company. Before using the power station power station, please read this user manual to ensure understanding and proper use. After reading the user manual, please keep it well for future reference. Improper operation may cause serious injury to yourself or others, or result in product damage and property loss. Once using power station, you are deemed to have understood and accepted all terms and contents herein. Users promise to be responsible for their actions and all consequences arising therefrom. We shall not be liable for any loss arising from users not following this user manual. In compliance with laws and regulations, the company reserves the right of nal interpretation of this document and all related documents of this product. Subject to update, revision or termination without prior notice, please visit the ocial website for the latest product information. FCC Statement This device complies with Part of the FCC Rules. Operation is subject to the following two conditions:
()This device may not cause harmful interference.
()This device must accept any interference received, including interference that may cause undesired operation. Changes or modications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Note:This equipment has been tested and found to comply with the limits for a class B digital device,pursuant to Part of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequence energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipmemt does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an autlet on a circuit dierent from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. The device has been evaluated to meet general RF exposure requirement, This equipment should be installed and operated with a minumum distance of cm between the radiator and your body. ISED Statement This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
This device may not cause interference. This device must accept any interference, including interference that may cause undesired operation of the device. This equipment should be installed and operated with a minimum distance of cm between the radiator and your body. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables auxappareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes :
()l'appareil ne doit pas produire de brouillage, et () l'utilisateur de l'appareil doit accepter toutbrouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre lefonctionnement. Cet quipement doit tre install et utilis avec une distance minimale de cm entre le radiateur et votre corps.