Blue Connect Module Take control of your sanitary ware with CELECs smart Blue Connect module. Connected sanitary ware offers improved hygiene and experience in washrooms whilst optimising maintenance and management of your efficiency. Installation data, alerts and remote commands are available via smartphone for point to point access and PC for network wide access to all installations. The module can be controlled by the Blue Connect App which works on both Android and iOS, on smartphones as well as tablets. It can also communicate with a Gateway to connect to a local area network (LAN) or wide area network (WAN). Optional flow rate and temperature sensors Material compatibility Advantages Monitor data to
- Identify installation problems and anomalies
- Anticipate maintenance interventions
- Optimise cleaning schedules depending on affluence
- Record the water consumption of your sanitary ware installations Shut-off installations remotely for cleaning or maintenance purposes Log data to
- Verify respect of hygiene procedures
- Track anti-legionella and bacteria rinse cycles
- Monitor actual water consumption for detection and solenoid valve maintenance leak
- Monitor actual water temperature for anti-
scalding protection and legionella control Alerts for battery replacement and maintenance Wireless low energy communication protocol for operation with batteries Download statistics Applications Kitchen faucet Bathroom faucet Shower WC Urinal Soap dispenser Characteristics Operating voltage 4-12VDC Average consumption 100 A Communication frequency 2.4GHz Status LED Green / Red Connectors Waterproof IP67 (adapters available on request) Software update Over the air Operating temperature 0 to +50C Storage temperature
-20 to +70C Europe Certification RED 2014/53/EU directive compliance Celec sensor, solenoid valve, temperature probe, flow meter as well as CELEC approved pumps and motors. Check with CELEC for compatibility with non-CELEC components. FCC ID: 2AVPG-MCX This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference including interference that may cause undesired operation. received, Also, some specific recommendations for exposure to magnetic fields must be followed: this equipement complies with FCCs radiation exposure limits set forth an uncontrolled environment conditions:
under 1- This equipment should be installed and operated such that a minimum separation distance of 20cm is maintained between the radiato
(antenna) and users nearby persons body at all times. following the 2 - This transmitter must be co-located or operating in conjunction with any other antenna or transmitter. USA Certification THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USERS AUTHORITY TO OPERATE THE EQUIPMENT. Memory capacity 4Mb Temperature probe type NTC Power source Protection Batteries or power supply IPx5 1/3 Installation Make the connections to the Blue Connect module in the following order. The first 3 steps of the installation process are optional and depend on the installations configuration (e.g. if neither flow meter nor temperature probe are used then step 2 connection is not required). 1/ Connect the sensor connectors to the top of the module above the sensor logo (optional). 2/ Connect the flow meter and temperature modules on the side of the module (optional). 3/ Connect the solenoid valve to the connector under the water droplet logo (optional). 4/ Connect the power source to the connector under the electricity logo. 5/ Screw into the fixing lugs to hold the Blue Connect in place. If the module needs to be disconnected for any reason, carry out the above steps in reverse order. Dimensions Right view Front view Left view Sensor connectors 68 mm 25.5 mm m m 0 7 m m 8 5 Temperature connector Sticker position Power supply connector Valve connector Rear view Breakable fixing lug Area for Velcro or double side tape Breakable fixing lug 2/3 Associated products IR Sensors CBS 146 Solenoid valve Micro valve Integrated multifunction IR sensor Compact Background Suppression sensor 6V latching solenoid valve 6V latching solenoid valve Temperature probe RI020 Power supply 6 AA battery holder Power supply 6V 1A 3/3 Module Bluetooth Take control of your sanitary ware with CELECs smart Blue Connect module. Connected sanitary ware offers improved hygiene and experience in washrooms whilst optimising maintenance and management of your efficiency. Installation data, alerts and remote commands are available via smartphone for point to point access and PC for network wide access to all installations. The module can be controlled by the Blue Connect App which works on both Android and iOS, on smartphones as well as tablets. It can also communicate with a Gateway to connect to a local area network (LAN) or wide area network (WAN). Optional flow rate and temperature sensors Material compatibility Advantages Monitor data to
- Identify installation problems and anomalies
- Anticipate maintenance interventions
- Optimise cleaning schedules depending on affluence
- Record the water consumption of your sanitary ware installations Shut-off installations remotely for cleaning or maintenance purposes Log data to
- Verify respect of hygiene procedures
- Track anti-legionella and bacteria rinse cycles
- Monitor actual water consumption for detection and solenoid valve maintenance leak
- Monitor actual water temperature for anti-
scalding protection and legionella control Alerts for battery replacement and maintenance Wireless low energy communication protocol for operation with batteries Download statistics Applications Kitchen faucet Bathroom faucet Shower WC Urinal Soap dispenser Characteristics Operating voltage 4-12VDC Average consumption 100 A Communication frequency 2.4GHz Status LED Green / Red Connectors Waterproof IP67 (adapters available on request) Software update Over the air Operating temperature 0 to +50C Storage temperature
-20 to +70C Europe Certification RED 2014/53/EU directive compliance Celec sensor, solenoid valve, temperature probe, flow meter as well as CELEC approved pumps and motors. Check with CELEC for compatibility with non-CELEC components. FCC ID: 2AVPG-MCX This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference including interference that may cause undesired operation. received, Also, some specific recommendations for exposure to magnetic fields must be followed: this equipement complies with FCCs radiation exposure limits set forth an uncontrolled environment conditions:
under 1- This equipment should be installed and operated such that a minimum separation distance of 20cm is maintained between the radiato
(antenna) and users nearby persons body at all times. following the 2 - This transmitter must be co-located or operating in conjunction with any other antenna or transmitter. USA Certification THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USERS AUTHORITY TO OPERATE THE EQUIPMENT. Memory capacity 4Mb Temperature probe type NTC Power source Protection Batteries or power supply IPx5 1/3 Installation Make the connections to the Blue Connect module in the following order. The first 3 steps of the installation process are optional (provided that there is at least one of these options) and depend on the installations configuration
(e.g. if neither flow meter nor temperature probe are used then step 2 connection is not required). 1/ Connect the sensor connectors to the top of the module above the sensor logo (optional). 2/ Connect the flow meter and/or temperature probe on the side of the module (optional). 3/ Connect the solenoid valve to the connector under the water droplet logo (optional). 4/ Connect the power source to the connector under the electricity logo. 5/ Screw into the fixing lugs to hold the Blue Connect in place. If the module needs to be disconnected for any reason, carry out the above steps in reverse order. WARNING:
Make sure to connect the Blue Connect module in the right order Incorrect connection can damage the Blue Connect Module Dimensions 19,70 Black cap for futur option) Grey watertight female connector for sensor Sticker position 67,00 9,11 9,40 58,00 200 4,84 15,74 Grey watertight male connector for power supply 30,40 Grey watertight female connector 21 with screws 11,89 Black watertight female connector for valve 28,00 Black watertight male connector 9,54 200 Black watertight male connector for sensor Yellow watertight male connector for temperature 2/3 Associated products IR Sensors CBS 146 Solenoid valve Micro valve Integrated multifunction IR sensor Compact Background Suppression sensor 6V latching solenoid valve 6V latching solenoid valve Temperature probe RI020 Power supply 6 AA battery holder Power supply 6V 1A 3/3