INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL PROGRAMMING 1 Connect Internet The controller can connect to the Internet with LAN (wired) or with Wi-Fi (wireless). Make sure you are in the Admin Mode before you connect to the Internet. If you are not in Admin Mode, touch the upper left-hand corner of the display. Follow the instructions according to your application. OPTION 2 Connect through Wi-Fi (Wireless) 1. On the display select Wi-Fi Network. 2. Select the network the controller will use. 3. Enter the password for the network. 4. Select Login. OPTION 1 Connect with LAN (wired) The Local Area Network (LAN) port is a 10/100 Ethernet interface with an RJ45 jack for connecting the controller to a LAN in order for it to gain connectivity to the Internet. Use a straight, (i.e., non-crossover) cable to connect to a local hub, switch or router. Connect the Power/Internet Board to a LAN functionality is a supplementary feature. 1. Connect an Ethernet cable from your LAN to the LAN port on the Power/Internet Board. When connected properly, the green and amber LED on the Ethernet port will light/ icker. If the green LED is not lit, check the connections on the controller and the Ethernet hub. On the display, select Wired Network if dynamic con guration (DHCP) is desired or select Manual Setup for a static IP address. 2. LAN on Internet/Power Board ON Ferrite Core 2 Validate Setup On the display, select each tab in Admin Mode to validate setup
(network, inputs, outputs, etc.). Once you have validated the setup, exit Admin Mode. 16 INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL PROGRAMMING Gate Access (Wired) Disconnect power BEFORE making electrical connections. Below is an example of a wiring setup for gate access. Gate access can be wired to Door 1, 2, 3, or 4 on the Door Boards. LiftMaster Security+ 2.0 gate operators can also be programmed to communicate wirelessly instead of using a wired connection (refer to the following page). RFID RECEIVER with wiegand output WEIGAND KEYPAD PROXIMITY READER NOTE: The length of the unshielded wires should be kept to a minimum to avoid electrical noise. Power for RFID RECEIVER
(Not Provided) DO NOT use the power supply for the controller OR OR NOTE: For KPR2000 keypad, wire the pink and black (ground) wires together. l e p r u p
-
d e s u t o n l e u b
-
d e s u t o n w o l l e y
-
d e s u t o n l k c a b
-
D N U O R G d e r
-
c d V 2 1 e g n a r o
-
D E L N E E R G n w o r b
-
D E L D E R n e e r g
-
0 A T A D e t i h w
-
1 A T A D l i d e h s
-
D L E I H S REQUEST TO EXIT EXTERNAL FREE EXIT LOOP DETECTOR PUSH BUTTON OR STATUS
(Not applicable for wireless gate operator connections.) GATE OPERATOR
(connect to closed limit switch) EOL (End of Line) Resistor (1k ohm) PRIMARY RELAY GATE OPERATOR LiftMaster Security+ 2.0 gate operators can be programmed to communicate wirelessly instead of using a wired connection. Refer to the following page. OPEN COMMON Model MG1300 AUXILIARY RELAY MAGLOCK For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) or equivalent Use 18-22 AWG NORMALLY CLOSED For DC Power:
Install a 1N4005 diode or equivalent COMMON
+
Power for Maglock
(Not Provided) DO NOT use the power supply for the controller REQUEST TO EXIT GROUND STATUS NORMALLY OPEN COMMON NORMALLY OPEN COMMON NORMALLY CLOSED DOOR 1, 2, 3, or 4 AUXILIARY RELAY LIGHT Low Voltage Power Supply LOAD LINE L A R T U E N OR Isolation Relay NOTE: DO NOT run high voltage power within the ACXL enclosure. ALARM BYPASS COMMON NORMALLY OPEN 17 INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL PROGRAMMING Gate Access (Wireless) For use with LiftMaster Security+ 2.0 gate operators. 1 Enter Admin Mode Touch the upper left-hand corner of the controller display to enter Admin Mode. 2 Select Outputs and Relay Select the Outputs tab. Then select the desired relay on the left-hand side (1 through 4). 3 Press LEARN button on gate operator Press and release the LEARN button on the primary operator. The green XMITTER LED will light. NOTE: The operator will time out of programming mode after 180 seconds. 4 Press LEARN button on gate operator again Press and release the LEARN button again on the primary operator. The yellow NETWORK LED will light. 5 Select LEARN on display Select the LEARN button on the display and the Learn button will go from green to red. The gate operator and the controller will beep and the NETWORK LED on the gate operator will turn off indicating programming is successful. 6 Validate Validate functionality by selecting Test Relay on the controller display. 18 INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL PROGRAMMING Door Access Disconnect power BEFORE making electrical connections. Below is an example of a wiring setup for door access. Door access can be wired to Door 1, 2, 3, or 4 on the Door Boards. RFID RECEIVER with wiegand output WEIGAND KEYPAD PROXIMITY READER NOTE: The length of the unshielded wires should be kept to a minimum to avoid electrical noise. Power for RFID RECEIVER
(Not Provided) DO NOT use the power supply for the controller OR OR NOTE: For KPR2000 keypad, wire the pink and black (ground) wires together. REQUEST TO EXIT PROXIMITY SENSOR PUSH BUTTON l e p r u p
-
d e s u t o n e u b l
-
d e s u t o n w o l l e y
-
d e s u t o n k c a b l
-
D N U O R G d e r
-
c d V 2 1 e g n a r o
-
D E L N E E R G n w o r b
-
D E L D E R n e e r g
-
0 A T A D e t i h w
-
1 A T A D l i d e h s
-
D L E I H S SUPERVISED (DOOR STATUS) OR DOOR SENSOR
(SUPERVISED) OR DOOR SENSOR
(NON-SUPERVISED) EOL (End of Line) Resistor
(1k ohm) PRIMARY RELAY Model HES(R) 1006CLB(R) DOOR STRIKE Power for Door Strike
(Not Provided) Use 18-22 AWG For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) or equivalent COMMON
+
NORMALLY OPEN For DC Power:
Install a 1N4005 diode or equivalent OR Model MG1300 MAGLOCK For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) or equivalent Use 18-22 AWG NORMALLY CLOSED For DC Power:
Install a 1N4005 diode or equivalent COMMON
+
Power for Maglock
(Not Provided) DO NOT use the power supply for the controller REQUEST TO EXIT GROUND SUPERVISED NORMALLY OPEN COMMON NORMALLY CLOSED NORMALLY OPEN COMMON AUXILIARY RELAY DOOR 1, 2, 3, or 4 LIGHT LOAD LINE L A R T U E N OR Low Voltage Power Supply Isolation Relay NOTE: DO NOT run high voltage power within the ACXL enclosure. ALARM BYPASS COMMON NORMALLY OPEN 19 INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL PROGRAMMING Wiegand Proximity Reader The controller is designed speci cally for the HID PROX-POINT+ MINI READER proximity reader to be mounted on the faceplate. 1. Disconnect power. 2. 3. Remove the mounting plate and gasket from the controller. Use a bench vise with soft jaws to hold the mounting plate and drill a hole for the cable with a 5/16" drill bit. Drill two mounting holes with a 7/64" drill bit. Make the threads using the self-tapping screws provided with the HID reader. NOTE: Thread the screw and remove. Clean the mounting hole thoroughly until the entire thread is made. 4. Install the proximity reader and secure with the screws. 5. Reinstall the gasket and mounting plate onto the controller. 6. 7. Apply silicon around the cable hole. 8. The proximity reader can be wired to any of the 4 Wiegand Inputs on the door control boards. Insulate any unused wires from the controller to prevent a short. (Refer to instructions supplied with your Wiegand device for more information.) 9. Connect power. 10. Refer to LiftMaster Cloud for programming. Proximity Reader Gasket Mounting Plate Mounting Holes Cable Hole ON Mounting Plate Use 18-24 AWG Card Reader is wired to WEIGAND INPUT NOTE: The length of the unshielded card reader wires should be kept to a minimum to avoid electrical noise. k c a b l d e r n w o r b e g n a r o e t i h w n e e r g l d e h s i WEIGAND INPUT 20 INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL PROGRAMMING Wiegand Output Disconnect power BEFORE making electrical connections. The controller offers a Wiegand output capable of 26 bit transmission of the following data:
Success Call with access granted by the resident. The controller will provide a LMC speci ed facility code followed by the Directory Code of the resident that granted access. And/Or Successful access through Entry Code. The controller will provide a LMC speci ed facility code followed by the successful Entry Code. The two facility codes should be different to prevent duplicate code transmission with the Wiegand Output. ON Data 0 Common Data 1 Third Party Access System Wiegand Input DOOR BOARD 1 21 INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL PROGRAMMING Postal Lock Remove the nuts, retainer bracket, and plug. Discard the retainer bracket and plug. Install the postal lock reusing the nuts previously removed. 1. 2. The postal lock switch is wired from the factory. Retainer Bracket Plug Postal Lock 22 INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL PROGRAMMING Loop Detector Board Disconnect power BEFORE making electrical connections. The Loop Detector Board provides Auto Call functionality that is available through the auxiliary switch setting. 1. Secure the Loop Detector Board to the standoffs in the controller with the provided screws. 2. Connect the wire harness from the Loop Detector Board to the Power/Internet Board. 3. Connect the loop wires to the input on the Loop Detector Board. 4. Plug in the loop detector (model LOOPDETLM). 5. Set both switches on the Loop Detector Board to ON (auxiliary setting). Refer to LiftMaster Cloud for programming. LOOP MODE SW1 SW2 EXIT INTERRUPT SHADOW AUXILIARY Not supported Not supported Not supported ON ON LOOP DETECTOR BOARD ON Switches Plug-in Loop Detector Model LOOPDETLM Loop Wiring Wire Harness ON 23 INTRODUCTION PRE-INSTALL INSTALL NETWORK ACCESS CONTROL PROGRAMMING Login to your LiftMaster Cloud Account then follow the steps below. 1Create a Facility 2 Add New Controller(s) 3 Add Door(s) 8 Add People 1. On the left navigation bar, click Facilities, and click Add facility. 2. Enter the following information:
Facility name Directory code length
(required eld) Address City/town State Zip code Country (required eld) Time zone (required eld) Contact information- This is required. The contact is typically the property manager 3. Click Save. The Control Panel # is required to add a controller to a facility. The Control Panel # is located on the product label. 1. On the left navigation bar, click Facilities or Dashboard. 2. Select the name of the facility where the new controller will be added. 3. Click on the Controllers tab. 4. Click Add New Controller. 5. Enter the Control Panel # (CP#) and the name of the controller. 6. Click Save. The Controller will appear on the list, a browser refresh may be necessary. NOTE: Door 1 is automatically created and associated to the Door 1 relay. This step is to con gure Relay 2. 1. On the left navigation bar, click Facilities or Dashboard. 2. Select the facility. 3. Click on the Controllers tab and select the controller you want to add the door to. 4. Click on the Doors tab next to the Controller Settings. 5. Select Relay 2 to control the door. 6. Click Add Door. 7. Enter the name of the door. 8. Click Save and Close. 4 Add Schedule(s) 5 Create Group(s) 6 Create Zone(s) 1. On the left navigation bar, click 1. On the left navigation bar, click Schedules. 2. Select the name of the facility. 3. Click Add Schedule and enter schedule information:
Name of schedule Description of schedule Do not select an Enabling Group unless you want a member of the enabled group to activate the schedule when they enter their entry code. NOTE: The schedule is not applied or activated until a member of the group accesses the property using a credential or pin. 4. To select a range of hours and days, click on the hour and day and drag to create the schedule or you may click on individual hours and days. 5. Add holidays and exceptions. 6. Click Save. Groups. 2. Select the facility you are creating a group for. 3. Click Add Group. 4. Enter a name for the new 5. Select the Status (active or 6. Click People and click Add group. suspended). users+. 7. Select the people for the group by clicking on the + next to the name of the person. 8. Add the zones for this group by, click Zones and click Add Zones+. 9. Select the zones by clicking on the + next to the name of zone. 10. Click Save. 1. On the left navigation bar, click Facilities or Dashboard. 2. Select the facility. 3. Click on the Zones tab. 4. Click Add New Zone. 5. Enter name of the zone. 6. Click Doors. 7. Click Add doors+ and click on the + next to the name of the door. 8. Click on Groups. 9. Click on Add Groups+ and select the Groups for the new zone. 10. Select the schedule from the drop-down list. 11. Click Save. 7 Add a Credential 1. On the left navigation bar, click Credentials. 2. Select the facility. 3. Click Add credential. 4. Select the Type: Card or transmitter. 5. Select the Format: Standard 26 bit or 30-Bit Wiegand. 6. Enter the card or transmitter information:
7. Click Save. NOTE: If adding multiple credentials, click Bulk load, enter the rst and last number in the series, the offset of the rst card, and the facility code. Card number Offset Facility code Vendor code (30-Bit Wiegand ONLY) 24 24 1. On the left navigation bar, click People. 2. Select the facility. 3. Click Add Person. 4. From the Pro le tab, Personal, enter the following information:
Email (optional) First and last name Role (use -- in most cases) 5. In Contact, select the Do not disturb schedule check box if desired. 6. In Contact, enter the following information:
Phone numbers Address, city, state, and zip code 7. Click, Save. 8. Click the Vehicle Information tab, enter vehicle information if desired. 9. Click Add a new vehicle. 10. Enter the vehicle information:
11. Click Add vehicle to add another Year Make Model State License plate number Color vehicle to the persons pro le. 12. Click, Save. 13. Setup Facility Access. If the person is to be called by the system you will need to set up the Facility Access Directory. a. From the add people screen, click the Facility Access tab. b. Enter the directory information, click Verify. If you want the system to automatically assign a directory code, click Generate Code. c. Enter a PIN, click Verify. If you want the system to automatically assign a PIN, click Generate PIN. Select Credentials for this person by clicking in the blank space in the Cards/Transmitters eld and select one a credential. a. If you want to set activation and expiration dates, click the Calendar icon for activation, select the date for activation. Click the Calendar icon for expiration, select the date you want their access to expire. b. Select the Groups(s) for this person, click in the blank space in the Access Groups eld. 14. Set Access 15. Click Save. Wiring Diagram white red black green white red POWER/INTERNET BOARD ON RADIO ANTENNA Not responsible for conflicts between the information listed in the wiring diagram and the requirements of your local building codes. The information is for suggested use ONLY. Check your local codes BEFORE installation. orange blue red black white purple black white purple blue green yellow orange red 9 10 7 8 5 6 3 4 1 2 1 - Red 2 - Orange 3 - Yellow 4 - Green 5 - Blue 6 - Purple 7 - Not used 8 - White 9 - Black 10 - Not used k c a b l d e r MICROPHONE Wi-Fi ANTENNA 1 - Red 2 - Orange 3 - Yellow 4 - Blue 5 - Green 6 - Purple 7 - Not used 8 - White 9 - Black 10 - Not used 10 2 9 1 4 3 8 7 6 5 SENSOR BOARD black red white yellow white green black black green white yellow DOOR BOARD DOOR BOARD POSTAL LOCK SWITCH 25 SPEAKER Repair Parts COMING SOON PLEASE CONTACT LIFTMASTER FOR ALPHA TEST REPAIR PART INFORMATION:
1.877.232.7987 Accessories ITEM Back Box and Trim Kit ACXL Hood Kit Card Reader Multi-class SE RP10 Mini Mullion Radio Antenna Extension (15 foot) Wi-Fi Antenna Extension (15 foot) Wiegand Keypad/Proximity Reader Wiegand Proximity Reader Loop Detector Kit (Complete with: Loop Detector Board, Plug-In Loop Detector [model LOOPDETLM], and wire harness) All LiftMaster MyQ/UL325 compatible gate operators Passport 3-Button Visor Remote Control MAX Passport 3-Button Mini Remote Control MAX Passport 3-Button Mini Proximity Remote Control MAX Passport Lite 1-Button Visor Remote Passport Lite 1-Button Key Chain Remote Passport Lite 1-Button Mini Proximity Remote
* Available in 10 and 100 packs, replace X with 10 or 100 26 PART NUMBER ACXLTK ACXLHOOD LMMC-MINI 86LM WIFIEXT KPR2000 PPLX TBD PPV3M PPK3M PPK3PHM PPLV1-X*
PPLK1-X*
PPLK1PH-X*
Con guration Sheet Record device information and con guration settings below. Controller Name:
NOTE: Any user of the system is subject to the terms outlined in the product EULA. Notes:
DEVICE CONFIGURATION:
DOOR 1 INPUTS OUTPUTS DOOR 2 INPUTS OUTPUTS DOOR 3 INPUTS OUTPUTS DOOR 4 INPUTS OUTPUTS Notes:
Notes:
Notes:
Notes:
DOOR/GATE NAME:
WIEGAND PRIMARY RELAY N.O. DOOR/GATE NAME:
WIEGAND PRIMARY RELAY N.O. DOOR/GATE NAME:
WIEGAND PRIMARY RELAY N.O. DOOR/GATE NAME:
WIEGAND PRIMARY RELAY N.O. REX N.C. REX N.C. REX N.C. REX N.C. 27 STATUS EOL (Y / N) AUXILIARY RELAY N.O. N.C. STATUS EOL (Y / N) AUXILIARY RELAY N.O. N.C. STATUS EOL (Y / N) AUXILIARY RELAY N.O. N.C. STATUS EOL (Y / N) AUXILIARY RELAY N.O. N.C. Legal Disclaimers Federal Communications Commission (FCC) Compliancy This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation or when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Increase the distance between the equipment and receiver. Connect the equipment to a circuit other than the one to which the receiver is connected. Consult the dealer for help. Canada-Underwriters Laboratories (C-UL) Compliancy For C-UL Listed applications, the controller shall be installed in accordance with Part 1 of the Canadian Electrical Code. Documentation Disclaimer and Restrictions Information in this document is subject to change without notice and does not represent a commitment on the part of LiftMaster. For the most up-to-date information, visit www.LiftMaster.com. This document and the data herein shall not be duplicated, used or disclosed to others for procurement or manufacturing, except as authorized with the written permission of LiftMaster. The information contained within this document or within the product itself is considered the exclusive property of LiftMaster. All information in this document or within the hardware and software product themselves is protected by the copyright and/or other intellectual property laws of the United States. UL 294 Access Control Unit Level 1 NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modi cations of this digital device are prohibited. THERE ARE NO USER SERVICEABLE PARTS. Any changes or modi cations not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Part 15 of the FCC rules and IC License-Exempt RSS Standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- This device must be installed in a way where a minimum 8" (20 cm) distance is maintained between users/bystanders and device. AVIS : Les rgles de la FCC et/ou dIndustrie Canada (IC) interdisent tout ajustement ou toute modi cation de ce rcepteur. IL NEXISTE AUCUNE PICE SUSCEPTIBLE DTRE ENTRETENUE PAR LUTILISATEUR. Tout changement ou toute modi cation non expressment approuv par la partie responsable de la conformit peut avoir pour rsultat d'annuler l'autorit de lutilisateur de faire fonctionner lquipement. Ce dispositif est conforme la partie 15 des rgles de FCC et des normes Permis-Exemptes dIC RSS. Son utilisation est assujettie aux deux conditions suivantes : (1) ce dispositif ne peut causer des interfrences nuisibles, et
(2) ce dispositif doit accepter toute interfrence reue, y compris une interfrence pouvant causer un fonctionnement non souhait. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. Ce dispositif a t mis lessai et dclar conforme aux limites tablies pour les dispositifs numriques de classe B, conformment larticle 15 des rgles de la FCC. Cette conformit a pour but de fournir une protection raisonnable contre les interfrences nuisibles dans une installation rsidentielle. Cet quipement gnre, utilise et peut mettre des frquences radio et, sil nest pas install et utilis conformment aux instructions, causer des interfrences nuisibles aux communications radio. Cependant, il nexiste aucune garantie que des interfrences ne se produiront pas dans une installation particulire. Si cet quipement provoque des interfrences nuisibles la rception dune diffusion sonore ou visuelle, ce qui peut tre dtermin en lallumant et en lteignant, lutilisateur est invit essayer de rsoudre ce problme en prenant une ou plusieurs des mesures suivantes :
- Rorienter ou dplacer antenne de rception.
- Augmenter la distance entre lquipement et le rcepteur.
- Brancher lappareil une prise sur un circuit diffrent de celui du rcepteur.
- Pour obtenir de laide, consulter le dtaillant ou un radiotechnicien expriment.
- Ce dispositif doit tre install de manire ce quune distance dau moins 20 cm (8 po) soit maintenue entre les utilisateurs/passants et le dispositif. 28 Warranty LiftMaster (Seller) warrants to the rst purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing. Failure to comply strictly with those instructions will void this limited warranty in its entirety. If, during the limited warranty period, this product appears to contain a defect covered by this limited warranty, call 1-800-528-2806 before dismantling this product. Then send this product, pre-paid and insured, to our service center for warranty replacement. Products returned to Seller for warranty replacement, which upon receipt by Seller are con rmed to be defective and covered by this limited warranty, will be replaced (at Sellers sole option) at no cost to you and returned pre-paid. Defective parts will be replaced with new or factory-rebuilt parts at Sellers sole option. THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, AND OF ANY OTHER OBLIGATIONS OR LIABILITY ON SELLERS PART. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE, DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE, MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT), LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT, PROBLEMS RELATED TO INTERFERENCE, OR REPLACEMENT OF BATTERIES. UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLERS LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you speci c legal rights, and you may also have other rights which vary from state to state. 29 Wi-Fi is a registered trademark of Wi-Fi Alliance. ALPHA 2016 LiftMaster All rights reserved.