all | frequencies |
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|
manual | photo | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual rev.1 | Users Manual | 2.17 MiB | April 09 2023 / April 11 2023 | |||
1 |
|
External Photo | External Photos | 174.81 KiB | April 09 2023 / April 11 2023 | |||
1 |
|
Label and Location | ID Label/Location Info | 3.07 MiB | April 09 2023 / April 11 2023 | |||
1 |
|
ACB Template Cover Letter FCC Change ID 1 to be signed by orignal applicant | Cover Letter(s) | 410.20 KiB | April 09 2023 / April 11 2023 | |||
1 |
|
ACB Template Cover Letter FCC Change ID 2 to be signed by new applicant | Cover Letter(s) | 107.14 KiB | April 09 2023 / April 11 2023 | |||
1 |
|
ACB-Covered-List-Attestation | Attestation Statements | 161.93 KiB | April 09 2023 / April 11 2023 | |||
1 |
|
ACB-FCC-Agency-Letter | Cover Letter(s) | 541.40 KiB | April 09 2023 / April 11 2023 | |||
1 |
|
ACB-U.S.-Agent-Letter | Attestation Statements | 96.92 KiB | April 09 2023 / April 11 2023 | |||
1 |
|
Model Difference Declaration | Cover Letter(s) | 84.93 KiB | April 09 2023 / April 11 2023 |
1 | User Manual rev.1 | Users Manual | 2.17 MiB | April 09 2023 / April 11 2023 |
EV Charger INSTALLATION AND USAGE GUIDE Chargenetic Inc. TABLE OF CONTENTS Safety Information 1.Safety Information..............................................................................................2-4 2.Specifications.................................................................................................5-7 3.Check Box Contents...............................................................................................8 4.Tools Needed........................................................................................................9 5.Installation Overview......................................................................................10-24 Step 1: Download the APP (Smart Home Version) ..................................................10 Step 2: Download the OCPP Configuration Tool......................................................11 Step 3: How is the EV Charger Powered..................................................................12 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR ELECTRIC SHOCK!
Improper connection of the equipment- grounding conductor may result in a risk of electric shock, leading to death or serious injury. Topcharge recommends that installation be performed by a licensed electrician or other qualified professional in accordance with the regional electrical code where it is being installed to ensure the Topcharge EV Charger is properly grounded. Do not modify the provided plug if it will not fit the outlet, have a proper outlet installed by a licensed Step 4: Find a Place for the EV Charger...................................................................13 electrician or other qualified professional. Step 5:Mark the Mounting Bracket Location...........................................................14 Step 6:Install the Mounting Bracket........................................................................14 Step 7: Install the Gun Cradle Beside the Charger....................................................15 Step 8: Mount the EV Charger.................................................................................15 GROUNDING INSTRUCTIONS For Plugged-In Installation:
This product must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment grounding conductor and a grounding plug. The plug Step 9a: Hardwired Instructions for Electricians.................................................16-20 must be plugged into an appropriate outlet that is properly installed and grounded in accordance Step 9b: Plugged in Instructions for Electricians................................................21-24 Step 10:Complete Setup..........................................................................................24 6.Charging your Vehicle..........................................................................................25 7.EV Charger LED Lights..................................................................................26-27 8.Troubleshooting Tips...........................................................................................28 9.FCC ....................................................................................................................29 10.Maintenance and Repair.....................................................................................30 with all local codes and ordinances. WARNING - Improper connection of the equipment-grounding conductor is able to result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product if it will not fit the outlet, have a proper outlet installed by a qualified electrician. For Hardwired Installation:
This product must be connected to a grounded, metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the 11.Service...............................................................................................................30 equipment grounding terminal or lead on the product. 02 Safety Information Moving and Storage Instructions Improper moving or storage of the Topcharge EV Charger may result in damage to the product that could result in a risk of fire or electric shock during subsequent use. Handle charger and packaging with care and avoid dropping it. When moving or lifting the Topcharge EV Charger, always grasp the unit by the charging station enclosure. Never carry or lift the Topcharge EV Charger by either the power cable or charging cord. Store the Topcharge EV Charger indoors and in its original packaging until it is ready to be installed. Storage temperature should be between -22F to 122F (-30C to 50C). IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR ELECTRIC SHOCK Read all the instructions before using this product. This device should be supervised when used around children. Do not put fingers into the electric vehicle connector. The Topcharge EV Charger is intended for use with electric vehicles only. Specifically, it is intended only for charging vehicles not requiring ventilation during charging. Do not use the Topcharge EV Charger in any manner other than specified in this installation guide. Refer servicing to qualified service personnel. Do not attempt to disassemble or repair any of the components of the Topcharge EV Charger. There are no user serviceable parts inside. Do not use this product if the flexible power cord or EV cable is frayed, has broken insulation, or any other signs of damage. Do not use this product if the enclosure or the EV connector is broken, cracked, open, or shows any other indication of damage. Do not install the Topcharge EV Charger in environments with explosive gas or vapors;
nor where temperatures are outside its operating range of-22F to 122F (-30C to 50C). Use 105C wire, 6 AWG copper for setting 48A rating intended for field wiring connection. 03 04 Specifications Specifications Electrical Characteristics Safety Rated: 32A Max Single phase input: nominal voltage 208-240 VAC ~60 Hz Power: 7.6 kW at 240 VAC NEMA 14-50 or NEMA 6-50 10.2in
(260mm) 12.3in
(313mm) Input Cable Electrical Plug. Hardwired by licensed electrician Output Cable &
Connector 18 ft/5.5 m cable (25ft/7.5m optional) SAE J1772 standard compliant App Smart Grid Connectivity Firmware Emissions Reduction Enclosure Precision measurement of power, energy, voltage & current Automated notifications: time-of-use in effect, start of charge, end of charge, unit offline, unit back online, car not plugged in by a set time Built-in WIFI (802.11 b/g/n/2.4GHz) / Bluetooth Connectivity Over-the-air (OTA) upgradeable firmware Available via optional software upgrade Dynamic LED lights show charging status: standby, Device connectivity, charging in progress, fault indicator, network connectivity NEMA Enclosure Type4: Weatherproof, dust-tight IK10: Resistant polycarbonate case Quick-release wall mounting bracket included Operating Temperature: -22F to 122F (-30C to 50C ) Dimensions Main enclosure:12.3in x 10.2in x 4.1in (313mm x 260mm x 105mm) NEC625 compliant,UL2594 compliant, OCPP 1.6J,FCC Part 15 Class B, Energy Star ETL Listed Optional Optional 2 years limited product warranty Codes &
Standards Safety RFID 4G module Warranty 05 Electrical Characteristics Safety Rated: 40A Max Single phase input: nominal voltage 208-240 VAC ~60 Hz Power: 9.6 kW at 240 VAC NEMA 14-50 or NEMA 6-50 10.2in
(260mm) 12.3in
(313mm) Input Cable Electrical Plug. Hardwired by licensed electrician Output Cable &
Connector 18 ft/5.5 m cable (25ft/7.5m optional) SAE J1772 standard compliant App Smart Grid Connectivity Firmware Emissions Reduction Enclosure Dimensions Codes &
Standards Safety RFID 4G module Warranty Precision measurement of power, energy, voltage & current Automated notifications: time-of-use in effect, start of charge, end of charge, unit offline, unit back online, car not plugged in by a set time Built-in WIFI (802.11 b/g/n/2.4GHz) / Bluetooth Connectivity Over-the-air (OTA) upgradeable firmware Available via optional software upgrade Dynamic LED lights show charging status: standby, Device connectivity, charging in progress, fault indicator, network connectivity NEMA Enclosure Type4: Weatherproof, dust-tight IK10: Resistant polycarbonate case Quick-release wall mounting bracket included Operating Temperature: -22F to 122F (-30C to 50C ) Main enclosure:12.3in x 10.2in x 4.1in (313mm x 260mm x 105mm) NEC625 compliant,UL2594 compliant, OCPP 1.6J,FCC Part 15 Class B, Energy Star ETL Listed Optional Optional 2 years limited product warranty 06 Specifications Check Box Contents 10.2in
(260mm) Electrical Characteristics Safety Rated: 48A Max Single phase input: nominal voltage 208-240 VAC ~60 Hz Power: 11.5 kW at 240 VAC 12.3in
(313mm) Input Cable Hardwired by licensed electrician Output Cable &
Connector 18 ft/5.5 m cable (25ft/7.5m optional) SAE J1772 standard compliant App Smart Grid Connectivity Firmware Emissions Reduction Enclosure Dimensions Codes &
Standards Safety RFID 4G module Warranty Precision measurement of power, energy, voltage & current Automated notifications: time-of-use in effect, start of charge, end of charge, unit offline, unit back online, car not plugged in by a set time Built-in WIFI (802.11 b/g/n/2.4GHz) / Bluetooth Connectivity Over-the-air (OTA) upgradeable firmware Available via optional software upgrade Dynamic LED lights show charging status: standby, Device connectivity, charging in progress, fault indicator, network connectivity NEMA Enclosure Type4: Weatherproof, dust-tight IK10: Resistant polycarbonate case Quick-release wall mounting bracket included Operating Temperature: -22F to 122F (-30C to 50C ) Main enclosure:12.3in x 10.2in x 4.1in (313mm x 260mm x 105mm) NEC625 compliant,UL2594 compliant, OCPP 1.6J,FCC Part 15 Class B, Energy Star ETL Listed Optional Optional 2 years limited product warranty Your new Topcharge EV Charger contains the following items. If any of these items are missing or if you believe theyve been damaged, call support immediately. x 2 x 1 x 1 EV charger installation and usage instruction APP/ OCPP Configuration Tool instruction. x 8 x 8 x 2 Eight drywallanchors Eight 7/32inch #12 Phillips screws 07 08 Tools Needed Step 1:Download the APP
(Smart Home Version) Here are the tools you will need to install the EV Charger. Use your phone to check the signal strength of your WIFI network where the EV Charger will be installed. Low/no signal may require a WIFI extender for the Charger to work. Download Topcharge APP onto your phone or tablet from the Apple App Store, from Google Play, create account and begin the setup process. Phillips, flathead and torx screwdrivers Pencil Adjustable Wrench IOS or Android phone or tablet Drill with a 5/16" drill bit Allen Wrench Rubber Mallet Bubble Level 09 10 Step 2:
Download the OCPP Configuration Tool Step 3:
How is the EV Charger Powered Use your phone or tablet to scan below QR code. Find OCPP Config Tool App, click Download to download the Tool to your phone or tablet and begin the configure process. Hardwired Installation See Step 9a EV Charger can supply a maximum charge of 48A to the EV Requires a dedicated dual pole breaker. We recommend 60A. CAUTION: To reduce the risk of fire, connect only to a circuit provided with 60 amperes maximum branch circuit over current protection in accordance with the National Electrical Code, ANSI/NFPA 70 and the Canadian Electrical Code, Part I, C22.1. Thanks to reduce the risk of fire, connect only to a circuit provided with branch circuit over current protection in accordance with the CSA C22.1-15 Canadian Electrical. Code, Part 1 (Canada) or NOM-001-SEDE Electrical installations
(Utility) (Mexico) or ANSI NFPA 70 National Electrical Code (USA) Plugged-in installation See Step 9b EV Charger can supply a maximum charge of 40A to the EV Requires a dedicated, 50A dual pole breaker. Requires a NEMA14-50R/6-50R receptacle outlet. 11 12 Step 4:
Find a Place for the EV Charger Step 5:
Mark the Mounting Bracket Location This device shall be mounted at a sufficient height from grade such that the height of the storage means for the coupling device is located between 24"(600 mm) and 48"(1.2 m) from grade; the distance from the vehicle allows slack for charging cable; temperatures are between
-22F to 122F; the charger is within range of WIFI signal; and if plugged-in, the distance from the NEMA outlet allows slack for a short cable. On the plasterboard / drywall where the charger will be installed, use a bubble level to draw a horizontal line where the top of the EV Charger will sit on the wall ensuring it is mounted at a sufficient height from grade such that the height of the storage means for the coupling device is located between 24"(600 mm) and 48" (1.2 m) from grade and allows slack for the NEMA cable if it will be plugged in. Then, align the top of the mounting bracket to the line and mark the 6 mounting holes. Step 6: Install the Mounting Bracket For each mark, drill a 5/16" hole in the wall. Use a Rubber Mallet to tap in the 6 drywall anchors. Install the bracket with 6 Phillips screws into the anchors. 13 14 Step 7:
Install the Gun Cradle Beside the Charger Step 9a-1:
Hardwired Instructions for Electricians Use a bubble level to draw a horizontal line at least 12"away from the mounting bracket at the height you'd like the cradle beside your EV Charger. Holding the gun cradle up to your line, mark the top two and bottom mounting holes of the gun cradle. If install the gun cradle on the wall or on the power distribution cabinet or board, drill a 5/16" hole in the wall for each mark. Use a Rubber Mallet to tap in 2 drywall anchors. Install the gun cradle with 2 Phillips screws into the anchors. A licensed electrician or other qualified professional can follow these instructions to hardwire the EV Charger to a breaker. If you plan to power your EV Charger with a NEMA 14-50R/6-50R receptacle outlet, skip to Step 9b. First, turn off the dedicated dual-pole breaker that will power the EV Charger. Step 8: Mount the EV Charger Step 9a-2:
Hardwired Instructions for Electricians Use the 2 M4X8 hand-screws to install the EV Charger on the mounting bracket. From the back of the EV Charger, use the Allen wrench to remove the 8 screws to detach the front cover. Use Adjustable wrench to remove waterproof joint. CAUTION: there's a cable connecting the cover to the circuit board in the Charger. To remove the cable, gently grab the cable bundle and pull it away from the circuit board. 15 16 Step 9a-3:
Hardwired Instructions for Electricians Step 9a-4:
Hardwired Instructions for Electricians Unscrew the screws for terminals L1, L2, and GND, to remove the NEMA cable wires. Unscrew the screws to remove the clamp securing NEMA cable. Then, remove the NEMA cable from the assembly. Finally, unscrew the nut holding the cable gland in place and remove it from the assembly. Ethernet Cable as shown Pull out the plug rod of the middle waterproof connector, insert the Ethernet cable, and tighten the nut. 17 18 Step 9a-5:
Hardwired Instructions for Electricians Step 9a-6:
Hardwired Instructions for Electricians Using 1-1/4" conduit and proper fittings for the connections, use copper conductor only, 105
,6 AWG for setting 48A rating from both phases of the breaker along with a ground/earth lead into the EV Charger assembly. Put the phase 1 lead into terminal L1, the phase 2 lead into terminal L2, and the ground into terminal GND and secure them with the screws, applying a tightening torque of 1.2 Nm. Gently reattach the cable to the cover and the circuit board. Then, from the back of the EV Charger, use the Allen wrench to replace the 8 screws to reattach the front cover. Step 9a-7:
Hardwired Instructions for Electricians Turn on the breaker and ensure that the power light on the front of the EV Charger is illuminated. 19 20 Step 9b-1:
Plugged in Instructions for Electricians Step 9b-2:
Plugged in Instructions for Electricians If a NEMA 14-50R receptacle outlet is not already at the EV Charger location, a licensed electrician or other qualified professional can follow these instructions to install one. First, turn off the dedicated dual-pole breaker that will power the EV Charger. Install a NEMA14-50R receptacle outlet with the ground facing downward ensuring the distance between the NEMA outlet and the EV Charger allows slack for a short cable. Bring leads from both phases of the breaker along with a ground/earth lead to the outlet and connect them. Neutral is not required. If a NEMA 6-50R receptacle outlet is not already at the EV Charger location, a licensed electrician or other qualified professional can follow these instructions to install one. First, turn off the dedicated dual-pole breaker that will power the EV Charger. 21 22 Step 9b-3:
Plugged in Instructions for Electricians Step 9b-4:
Plugged in Instructions for Electricians Install a NEMA6-50R receptacle outlet with the ground facing downward ensuring the distance between the NEMA outlet and the EV Charger allows slack for a short cable. Bring leads from both phases of the breaker along with a ground/earth lead to the outlet and connect them.Neutral is not required. Plug in the NEMA 14-50P/60-50P plug from the EV Charger into the receptacle outlet. Turn on the breaker and ensure that the power light on the front of the EV Charger is illuminated. Step 10: Complete Setup Your EV Charger is now ready to charge your vehicle. Factory setting: Base on the maximum EV charger capacity that the car system will accept. Default factory setting of charging mode is Plug and Play. To raise or lower the charge rate to match your breaker size and to take advantage of the numerous other features through Topcharge APP or OCPP Configuration Tool, follow the corresponding steps in User Instruction Manual to make changes. 23 24 Charging your Vehicle EV Charger LED Lights Factory setting: Base on the maximum EV charger capacity that the car system will accept. You can raise or lower this rate through the Topcharge APP or OCPP Configuration Tool. Default factory setting of charging mode is Plug and Play. If it is smart home charger, to switch to APP mode, please. refer to Topcharge APP instruction. If it is commercial charger
(OCPP version), switch the mode through the Topcharge OCPP Configuration Tool in the phone or tablet. To start charge the vehicle, open the port door and plug the EV Charger gun into the port. You will see the charge light on the EV Charger switch to solid green when it is connected to the vehicle. It will begin flash green, as the vehicle charges. Additionally, most EVs have indicator lights on the dashboard to let you know that you are charging. Do not attempt to drive your vehicle while the charge cable is connected to your vehicle. Power Off Solid Blue Connect Off Flash Green Solid Green Charge Off Flash Green Solid Green Wi-Fi/4G Off Solid Green Charger does not have power Charger has power Faulty charging signal from the car Charge Mode Pre-Charge Mode Idle Mode Charging Mode Pre-Charge Mode Not connected to WIFI/4G network Connected to the WIFI/4G network CAUTION: Do not touch and use this product when in case of failure. It is required to disconnect the power supply or have it handled by professionals. 25 26 EV Charger LED Lights Troubleshooting Tips The Topcharge APP is not finding my EV Charger after Ive installed it. Ensure the Charger has power:
Check for a green power light. Check the EV Charger is wired properly. Check that the breaker powering the EV Charger is turned on. Ensure your phone can connect to the EV Charger. Check your phone's Bluetooth is on. Try power cycling the breaker to which the EV Charger is connected. Try restarting the Topcharge APP. Try rebooting your phone. My vehicle is not responding or charging. Ensure that the latch on the EV charging cable handle is locked into place. If the handle is not latched securely, the vehicle will not charge. If the latch is pressed down during charging, charging automatically stops. Ensure that the vehicle is not set up to begin charging at a specific time of day. Fault Red light flashing every 3 seconds (once) Red light flashing every 3 seconds (twice) Red light flashing every 3 seconds (three times) Red light flashing every 3 seconds (four times) Red light flashing every 3 seconds (five times) Red light flashing every 3 seconds (six times) Input voltage is too high If plugged in, check that the NEMA14-50P or NEMA6-50P is plugged in securely. Check the supply breaker in your breaker panel for damage and replace if necessary. If issue persists, contact Support. In put voltage is too low If plugged in, check that the NEMA14-50P or NEMA6-50P is plugged in securely. Check the supply breaker in your breaker panel for damage and replace if necessary. If issue persists, contact Support. Output over current Unplug from car. Disconnect charger from power. Confirm there is no visible damage or foreign material in the EV gun. Return power to charger. If issue persists, contact Support. Charger has exceeded nominal temperature. Ensure the charger is installed where ambient temperatures will not exceed 122F (50C). If issue persists, contact Support. Current leakage. Unplug from car. Disconnect charger from power. Confirm there is no visible damage or foreign material in the EV gun. Return power to charger. If issue persists, contact Support. Charger is not grounded Ensure that the EV Charger is properly wired and grounded. Check the line and neutral connections, as they may be reversed in the adapter or outlet. Unplug and reboot EV charger. If issue persists, contact Support. Red light flashing every 3 seconds (seven times) CP line not properly connected. Red light flashing every 3 seconds (eight times) Relay fused in position Disconnect from power immediately. Contact Support. 27 28 FCC Maintenance and Repair The Topcharge EV Charger contains This device complies with Part 15 of the FCC Rules / Industry Canada license-exempt RSS standard
(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. To satisfy FCC / IC RF exposure requirements, a separation distance of 20cm or more should be maintained between the antenna of this device and persons during device operation. To ensure compliance, operations at closer than this distance is not recommended. Les antennes installes doivent tre situes de facon ce que la population ne puisse y tre expose une distance de moin de 20 cm. Installer les antennes de facon ce que le personnel ne puisse approcher 20 cm ou moins de la position centrale de l antenne. La FCC des ltats-unis stipule que cet appareil doit tre en tout temps loign dau moins 20 cm des personnes pendant son functionnement. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Always ensure that after charging, the charging cable is wrapped around the Wall Connector. Regularly inspect the Wall Connector and charging cable for signs of damage. lf damage is found, contact Topcharge. The Wall Connector contains no user-serviceable components. If the unit is not operating correctly, contact Topcharge. Wipe the outside of the wall Connector, the charging cable, and the connector end of the charging cable with a clean dry cloth to remove any accumulation of dust and dirt. WARNING: Turn off input power at the circuit breaker before cleaning the Wall Connector. WARNING: Do not use cleaning solvents, scouring, powder, or any type of abrasive pad to clean the wall connector, its charging cable, or the vehicle's charging port. CAUTION: To reduce the risk of electrical shock or equipment damage, do not allow liquid to enter the wall Connector while cleaning it. Service Need more assistance? Contact Topcharge Customer Service:
Customercare@topcharge.com 29 30
1 | Label and Location | ID Label/Location Info | 3.07 MiB | April 09 2023 / April 11 2023 |
Model Number:
TPC-C01RPro-32A Commercial Pro Wifi/BLE/RFID/4G Input:
208-240VAC, single phase,60Hz,32A Output:
208-240VAC,60Hz,32A max Temperature Rating:
-22F to 122F(-30C to 50C) Enclosure Rating:
NEMA Type 4 Date Code: XXXXXX Serial Number: XXXX CCID: XXXXXXX 5025109 Conforms to UL std UL 2594. Certified to CSA std C22.2 No. 280. Made in China Contains FCC ID: 2AC7Z-ESPC3WROOM Contains FCC ID: XMR201909EC25AFX Contains IC: 21098-ESPC3WROOM Contains IC: 10224A-2019EC25AFX FCC ID: 2BACA-H01R IC: 29907-H01R Model Number:
TPC-C01RPro-40A Commercial Pro Wifi/BLE/RFID/4G Input:
208-240VAC, single phase,60Hz,40A Output:
208-240VAC,60Hz,40A max Temperature Rating:
-22F to 122F(-30C to 50C) Enclosure Rating:
NEMA Type 4 Date Code: XXXXXX Serial Number: XXXX CCID: XXXXXXX 5025109 Conforms to UL std UL 2594. Certified to CSA std C22.2 No. 280. Made in China Contains FCC ID: 2AC7Z-ESPC3WROOM Contains FCC ID: XMR201909EC25AFX Contains IC: 21098-ESPC3WROOM Contains IC: 10224A-2019EC25AFX FCC ID: 2BACA-H01R IC: 29907-H01R Model Number:
TPC-C01RPro-48A Commercial Pro Wifi/BLE/RFID/4G Input:
208-240VAC, single phase,60Hz,48A Output:
208-240VAC,60Hz,48A max Temperature Rating:
-22F to 122F(-30C to 50C) Enclosure Rating:
NEMA Type 4 Date Code: XXXXXX Serial Number: XXXX CCID: XXXXXXX 5025109 Conforms to UL std UL 2594. Certified to CSA std C22.2 No. 280. Made in China Contains FCC ID: 2AC7Z-ESPC3WROOM Contains FCC ID: XMR201909EC25AFX Contains IC: 21098-ESPC3WROOM Contains IC: 10224A-2019EC25AFX FCC ID: 2BACA-H01R IC: 29907-H01R Model Number:
TPC-C01R-32A Commercial Wifi/BLE/RFID Input:
208-240VAC, single phase,60Hz,32A Output:
208-240VAC,60Hz,32A max Temperature Rating:
-22F to 122F(-30C to 50C) Enclosure Rating:
NEMA Type 4 Date Code: XXXXXX Serial Number: XXXX CCID: XXXXXXX 5025109 Conforms to UL std UL 2594. Certified to CSA std C22.2 No. 280. Made in China Model Number:
TPC-C01R-40A Commercial Wifi/BLE/RFID Input:
208-240VAC, single phase,60Hz,40A Output:
208-240VAC,60Hz,40A max Temperature Rating:
-22F to 122F(-30C to 50C) Enclosure Rating:
NEMA Type 4 Date Code: XXXXXX Serial Number: XXXX CCID: XXXXXXX 5025109 Conforms to UL std UL 2594. Certified to CSA std C22.2 No. 280. Made in China Model Number:
TPC-C01R-48A Commercial Wifi/BLE/RFID Input:
208-240VAC, single phase,60Hz,48A Output:
208-240VAC,60Hz,48A max Temperature Rating:
-22F to 122F(-30C to 50C) Enclosure Rating:
NEMA Type 4 Date Code: XXXXXX Serial Number: XXXX CCID: XXXXXXX 5025109 Conforms to UL std UL 2594. Certified to CSA std C22.2 No. 280. Made in China Contains FCC ID: 2AC7Z-ESPC3WROOM Contains IC: 21098-ESPC3WROOM FCC ID: 2BACA-H01R IC: 29907-H01R Contains FCC ID: 2AC7Z-ESPC3WROOM Contains IC: 21098-ESPC3WROOM FCC ID: 2BACA-H01R IC: 29907-H01R Contains FCC ID: 2AC7Z-ESPC3WROOM Contains IC: 21098-ESPC3WROOM FCC ID: 2BACA-H01R IC: 29907-H01R Model Number:
TPC-H01RPro-32A Residential Pro Wifi/BLE/RFID Input:
208-240VAC, single phase,60Hz,32A Output:
208-240VAC,60Hz,32A max Temperature Rating:
-22F to 122F(-30C to 50C) Enclosure Rating:
NEMA Type 4 Date Code: XXXXXX Serial Number: XXXX CCID: XXXXXXX 5025109 Conforms to UL std UL 2594. Certified to CSA std C22.2 No. 280. Made in China Model Number:
TPC-H01RPro-40A Residential Pro Wifi/BLE/RFID Input:
208-240VAC, single phase,60Hz,40A Output:
208-240VAC,60Hz,40A max Temperature Rating:
-22F to 122F(-30C to 50C) Enclosure Rating:
NEMA Type 4 Date Code: XXXXXX Serial Number: XXXX CCID: XXXXXXX 5025109 Conforms to UL std UL 2594. Certified to CSA std C22.2 No. 280. Made in China Model Number:
TPC-H01RPro-48A Residential Pro Wifi/BLE/RFID Input:
208-240VAC, single phase,60Hz,48A Output:
208-240VAC,60Hz,48A max Temperature Rating:
-22F to 122F(-30C to 50C) Enclosure Rating:
NEMA Type 4 Date Code: XXXXXX Serial Number: XXXX CCID: XXXXXXX 5025109 Conforms to UL std UL 2594. Certified to CSA std C22.2 No. 280. Made in China Contains FCC ID: 2AC7Z-ESPC3WROOM Contains IC: 21098-ESPC3WROOM FCC ID: 2BACA-H01R IC: 29907-H01R Contains FCC ID: 2AC7Z-ESPC3WROOM Contains IC: 21098-ESPC3WROOM FCC ID: 2BACA-H01R IC: 29907-H01R Contains FCC ID: 2AC7Z-ESPC3WROOM Contains IC: 21098-ESPC3WROOM FCC ID: 2BACA-H01R IC: 29907-H01R
1 | ACB Template Cover Letter FCC Change ID 1 to be signed by orignal applicant | Cover Letter(s) | 410.20 KiB | April 09 2023 / April 11 2023 |
Xiamen Topstar Co., Ltd No.696 Meixi Road, Tongan District, Xiamen City, Fujian Web Site: www.xiamentopstar.com.cn 886-592-7263847 Email: nsq@topstar.com.cn Province, P.R.China Tel:
Fax: 886-592-7263504 Federal Communications Commission, Date: 2023/3/3 Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD. 21046 Attention: Equipment Authorization Branch CHANG IN IDENTIFICATION OF EQUIPMENT We, responsibility that Xiamen Topstar Co., Ltd. Chargenetic INC
, declare on our sole may apply Change in FCC Identifier as established in 47CFR 2.933(b) for currently approved devices listed below. FCC ID: 2A9FM-TSE240VAUS Regards,
Signed by original applicant V1.0
1 | ACB Template Cover Letter FCC Change ID 2 to be signed by new applicant | Cover Letter(s) | 107.14 KiB | April 09 2023 / April 11 2023 |
Chargenetic INC Federal Communications Comission, Date: 2023/3/3 Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD. 21046 Attention: Equipment Authorization Branch CHANG IN IDENTIFICATION OF EQUIPMENT We, Chargenetic INC
, request to apply for a new FCC ID as established in 47CFR 2.933(b) for a currently approved device. This application will establish a new FCC ID: 2BACA-H01R Per 2.933(b) 1. The original identification is FCC ID: 2A9FM-TSE240VAUS 2. The original grant date is 01/09/2023 3. The equipment is electrically identical. There is no change in design, circuitry or construction. 4. The original test results are applicable and representative of this changed device. 5. Exterior photographs are included in this application. External photos with label location and type label sample drawing are electronically submitted as attachments. Sincerely,
Signed by new applicant V1.0
1 | ACB-Covered-List-Attestation | Attestation Statements | 161.93 KiB | April 09 2023 / April 11 2023 |
Chargenetic INC Certification Application Attestation Statements Date: March 28, 2023 American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 To Whom It May Concern:
Statement for 47 CFR section 2.911(d)(5)(i) ______ Chargenetic INC______ certifies that as of the date of the application the equipment for which authorization is sought is not covered equipment1 prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. If the equipment for which the applicant seeks authorization is produced by any of the entities identified on the current Covered List, including affiliates or subsidiaries of the named companies, the applicant must include an explanation on why the equipment is not covered equipment. Additional Explanation: <N/A>
Statement for 47 CFR section 2.911(d)(5)(ii) ______ Chargenetic INC_____ (the applicant) certifies that, as of the date of the filing of this application, the applicant - is / - is not identified on the Covered List as an entity producing covered equipment. Thank you, By:
(Signature2) ____Vincent Shao_________
(Print name) Title:
_____officer______________ Company:
_ Chargenetic INC__ Telephone:
_____001 626 899 6253________________ 1 The Commissions Covered List is published by the Public Safety and Homeland Security Bureau and posted on the Commissions website. This Covered List, which is periodically updated, identifies particular equipment, produced by particular entities, that constitutes covered equipment. https://www.fcc.gov/supplychain/coveredlist . 2 - Letters must be placed on appropriate letterhead. 022423-17 rev 6
1 | ACB-FCC-Agency-Letter | Cover Letter(s) | 541.40 KiB | April 09 2023 / April 11 2023 |
Chargenetic INC Authority to Act as Agent Date: March 27, 2023 American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 To Whom It May Concern:
______Intertek Testing Service Shanghai______ is authorized to act on our behalf, until otherwise notified, for applications to American Certification Body, Inc. (ACB). We certify that we are not subject to denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. Further, no party, as defined in 47 CFR 1.2002 (b), to the application is subject to denial of federal benefits, that includes FCC benefits. We also declare that the information provided to the FCC is true and correct to the best of our knowledge (47 CFR 2.911(d)) and we have been informed of the grantee responsibilities (47 CFR 2.909) with regard to certified equipment. Thank you, Agency Agreement Expiration Date: _____2023/3/3-2028/3/3 _____ By:
(Signature1) _______Vincent Shao_________
(Print name) Title:
________officer_______________ On behalf of: __ Chargenetic INC________________________
(Company Name) Telephone:
____001 626 899 6253______________________ 1 - Must be signed by applicant contact given for applicant on the FCC site, or by the authorized agent if an appropriate authorized agent letter has been provided. Letters should be placed on appropriate letterhead. 050222-17
1 | ACB-U.S.-Agent-Letter | Attestation Statements | 96.92 KiB | April 09 2023 / April 11 2023 |
Chargenetic, INC U.S. Agent Designation for Service of Process
(Applicant is Both Grantee and U.S. Agent) TO:
American Certification Body, Inc. 313 Park Avenue Suite 300 Falls Church, VA 22046 ATTENTION: FCC Certification Section 2.911(d)(7) Information This letter is to confirm that the Applicant will also serve as the U.S. Agent for Service of Process as required by 47 CFR 2.911(d)(7). The Applicant acknowledges that they must maintain an agent for no less than one year after terminating all marketing and importation OR the conclusion of any Commission-related proceeding involving the equipment. The Applicant further acknowledges their responsibility to inform the FCC whenever the Designated U.S. Agent information changes. Applicant Company name:Chargenetic, INC FRN #: 0033431669 Grantee Code:2BACA Contact Name:Vincent Shao Street Address:10010 Nicollet Lake Ln, Katy, TX 77494, USA City/Province/Zip:Texas/77494 Telephone No:001 626 899 6253 Email: Vince.lonestar@gmail.com Applicant Signature1:
Date:2023/3/3 Signed by (Printed Name/Title):Vincent Shao 1 - Letters must be placed on appropriate letterhead.
1 | Model Difference Declaration | Cover Letter(s) | 84.93 KiB | April 09 2023 / April 11 2023 |
Chargenetic, INC Model Difference Declaration We, Chargenetic, INC declare:
EV Charger:
TPC-H01RPro-32A, TPC-H01RPro-40A, TPC-H01RPro-48A, TPC-C01RPro-32A, TPC-
C01RPro-40A, TPC-C01RPro-48A, TPC-C01R-32A, TPC-C01R-40A, TPC-C01R-48A The products above are same except optional 4G module and max output current. Vincent Shao Chargenetic, INC Date: April 7, 2023
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2023-04-11 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter | Change in Identification |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2023-04-11
|
||||
1 | Applicant's complete, legal business name |
Chargenetic, INC
|
||||
1 | FCC Registration Number (FRN) |
0033431669
|
||||
1 | Physical Address |
10010 Nicollet Lake Ln, Katy, TX 77494, USA
|
||||
1 |
Katy, TX
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
h******@acbcert.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2BACA
|
||||
1 | Equipment Product Code |
H01R
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
V**** S******
|
||||
1 | Telephone Number |
001 6********
|
||||
1 | Fax Number |
001 6********
|
||||
1 |
V******@gmail.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Intertek Testing Services Limited Shanghai
|
||||
1 | Name |
S******** y********
|
||||
1 | Physical Address |
Building N0.86,1198 Qinzhou Road(North)
|
||||
1 |
Shanghai, 200233
|
|||||
1 |
China
|
|||||
1 | Telephone Number |
+8621********
|
||||
1 |
s******@intertek.com
|
|||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | EV charger | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Change in Identification | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
SHENZHEN STS TEST SERVICES CO.,LTD.
|
||||
1 | Name |
B**** Y********
|
||||
1 | Telephone Number |
+86 7********
|
||||
1 |
B******@stsapp.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 13.56000000 | 13.56000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC