all | frequencies |
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|
manual | photos | labels |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 2.04 MiB | September 10 2021 | |||
1 |
|
Internal Photos 1 | Internal Photos | 1.30 MiB | September 10 2021 | |||
1 |
|
External Photos | External Photos | 4.42 MiB | September 10 2021 | |||
1 |
|
Label | ID Label/Location Info | 92.25 KiB | September 10 2021 | |||
1 |
|
Location Label | ID Label/Location Info | 277.53 KiB | September 10 2021 | |||
1 |
|
Authorization Letter | Cover Letter(s) | 140.66 KiB | September 10 2021 | |||
1 |
|
Permanent Confidentiality Letter | Cover Letter(s) | 96.73 KiB | September 10 2021 | |||
1 |
|
SAR Exception | RF Exposure Info | 204.56 KiB | September 10 2021 | |||
1 |
|
Test Report | Test Report | 2.96 MiB | September 10 2021 | |||
1 |
|
Test Setup Photos | Test Setup Photos | 1.44 MiB | September 10 2021 |
1 | User Manual | Users Manual | 2.04 MiB | September 10 2021 |
Instructions
for Use
Thank you for choosing Elvie.
We’re pumped you’re here.
It’s our mission to create products that improve
women’s lives, so we hope Elvie Stride makes
a difference to yours.
Languages
English
Contents
1
1. Parts
1.1 Product description
1.2 Controls
2. Intended use
3. Safety
4. Getting ready
4.1 Charging
4.2 Taking Elvie Stride apart
4.3 Cleaning
4.4 Breast Shield sizing
4.5 Assembling Elvie Stride
4.6 Single-side pumping
5. Using Elvie Stride
5.1 Turning on Elvie Stride
5.2 Aligning your nipple
5.3 Finding the right in-bra fit
5.4 Starting your session
5.5 Modes and intensity settings
5.6 Automatic functions
5.7 Ending your session
5.8 Storing your milk
5.9 How to store Elvie Stride
6. Troubleshooting
7. Warranty
8. Product specifications
3
5
5
10
19
25
26
27
1
Additional help and support
The Pump with Elvie app can be downloaded from the
Apple App Store (for iPhone) or Google Play Store (for Android).
If you need any help with your Elvie Stride, please get in touch
with our Customer Care team. Visit elvie.com for their details.
For Customer Care contact details visit elvie.com
1. Parts
1.1 Product description
Elvie Stride is comprised of the parts and accessories
listed below. They can also be seen below and on page 4:
1 Hub
2 Cup Fronts
2 Cup Seals
2 Breast Shields (24 mm)
2 Caps
1 Tube Splitter
2 Short Tubes (for the Cups)
1 Long Tube (for the Hub)
1 Clip
1 Cover
2 Valves
2 Diaphragms
1 Charging Cable
Stopper
Cup Seal
Breast Shield
Getting started
1. Charge the Elvie Stride Hub
Plug in the Hub for five minutes to wake it up before
first use. Please note, Elvie Stride does not turn on while
it is charging. For more details, please read the Charging
section of this booklet.
2. Download the Pump with Elvie app
Download the Pump with Elvie app on your smart phone
to make use of your pump’s smart features:
•
•
•
Track sessions
Control Elvie Stride remotely
Personalize your pump preference settings
The Pump with Elvie app can be downloaded from
the Apple App Store (for iPhone) or Google Play Store
(for Android).
For the most up-to-date information on what devices
the app can be used with please visit elvie.com.
3. Learn how to set up your Elvie Stride
Read the Getting ready section of this booklet. It will take
you through cleaning, charging and finding your best fit.
4. Find out more
Find out what to expect from your first pumping session
by reading the Using Elvie Stride section of this booklet.
It will show you how to express with your Elvie Stride.
5. Get in touch
If you have any further questions, contact our Customer
Care team at elvie.com.
2
3
Diaphragm
Cup Front
Valve
Charging Port
Hub
Cap Seal
Cap
Cover
Clip
Short Tube
(for the Cups)
Tube Splitter
Tube Splitter
Stopper
Intensity Lights
Power
Intensity Settings
Charging Cable
Hub Connector
Long Tube (for the Hub)
1.2 Controls
Mode
Mode Light
Play/Pause
4
2. Intended use
Indications for use
The Elvie Stride is a breast pump to be used by lactating
women to express and collect milk from their breast. The
Elvie Stride is intended for a single user.
Operating life
The expected operating life of the replaceable, washable
components is six months. It is recommended that you
replace the washable components after long-term storage
or before pumping for your next child.
Contraindications
There are no known contraindications for use with
this product.
3. Safety
Warnings
Read all instructions before using. Elvie Stride is not
provided sterile. It must be cleaned and sanitized before
first use (see the Cleaning section).
It is recommended that you consult with a licensed
healthcare professional before using Elvie Stride if you
have an active implanted device that would be affected
by a magnetic field (e.g. pacemaker, implantable
cardioverter defibrillator).
When using electrical products, especially when children
are present, basic safety precautions should always be
maintained, including the following:
5
•
•
•
•
•
•
•
Never operate an Elvie Stride if it has been damaged,
is not working properly, or has been dropped into
water. If damage is found, immediately discontinue use.
In case of damage or wear, please replace parts
If the package appears damaged or tampered
with before use, do not use and contact our
Customer Care team
Do not submerge the Cap in water. It may be difficult to
dry and may risk liquid being sucked into the Hub
Regularly check that there is no residue or
condensation in the Tubes. The Tubes must be
completely dry before assembly; residue or
condensation can be drawn into the Elvie Stride Hub,
which could cause product failure. If there is milk in the
Tubes discontinue use, check the Diaphragm for damage
and contact Customer Care. If mold develops in the
Tubes, discontinue use and replace
Always inspect all parts before use for damage, liquid
and cleanliness. Elvie Stride must not be used if the
Diaphragm is damaged. A damaged Diaphragm risks
liquid being sucked into the Hub, which could
cause permanent damage resulting in no suction.
Keep sharp objects away from the Diaphragm
Do not immerse the Hub, Tubes, Tube Splitter
or Cap in water or other liquids. Wipe with a
clean, damp cloth
Do not drop or insert any foreign object into any
openings on the Hub and always close the
Charging Cap after charging
• Only use Elvie manufactured parts with Elvie Stride,
including the Charging Cable; do not substitute. Use of
accessories or cables other than those specified could
result in irreversible damage to your Hub
•
•
•
•
•
•
•
•
•
•
•
•
•
Elvie Stride is best paired with a charging adapter of
maximum output 5 V / 2.1 A or 10 W. See our website
FAQ for more information about charging Elvie Stride
During normal use, areas of the Hub may warm up
It is not necessary to have trained medical professionals
present during use/operation of this product
The Breast Shield is the part that should be
applied to the body
Do not store wet or damp parts, as mold may develop
Do not use flammable materials while using
Elvie Stride or connecting Elvie Stride to a charger
Elvie Stride should not be used while lying down,
engaging in strenuous activities or performing
activities with risk of harm such as operating
heavy machinery. Do not pump while driving
Do not pump until after giving birth, as breast
pumping can induce labor
Using a breast pump should not cause pain. Do not
try to express with an intensity setting that is too high or
uncomfortable. If excessive discomfort or pain is
felt during pumping, stop pumping, break the seal
around your nipple and discontinue the session
This product contains small parts, Tubes and a cable
that may present a hazard. Keep out of reach of children
Inspect for damage, clean and sanitize washable
components that come into contact with your
breast and breast milk prior to first use
Clean all parts that come into contact with your
breast and breast milk, and inspect for damage
after every use
This is a single-user product. Use by more than one
person may present a health risk and voids the warranty
6
7
• Only use Elvie Stride for its intended use as
described in this manual
•
Do not expose Elvie Stride or its components
to direct sunlight
Do not use Elvie Stride while sleeping or overly drowsy
• Wash your hands thoroughly with soap and water
•
•
•
•
•
•
•
•
•
•
Always break the seal around your nipple before
removing Elvie Stride from your breast
Do not wear Elvie Stride when not pumping
Elvie Stride and its components are not heat resistant.
Keep away from heat sources
Elvie Stride uses Bluetooth technology. Please follow
airline rules for the use of portable electronic devices
when flying. Furthermore, high altitudes, including
while in a pressurized aircraft cabin, will affect the
performance of Elvie Stride
Portable and mobile frequency communications
equipment can affect the Hub
Please note that the Pump with Elvie app is
not required to use Elvie Stride. In the case of
disconnection from the app all pump controls are still
accessible via the device
Precautions
Always ensure all parts are completely dry before
assembling. Any liquid left on the Diaphragm risks
being sucked into the Hub, which could cause
product failure
Do not use harsh chemicals to clean the Breast
Shield, Cup Front, Cup Seal, Valve or Diaphragm
Do not place the Hub in the fridge or freezer
before touching Elvie Stride, its components or your
breasts. Avoid touching the inside of the Cup Fronts
and Breast Shields
• Only use drinking-quality tap water or bottled water
for cleaning components that come into contact
with milk
Contact your healthcare professional if you express
minimal or no milk, or if expression is painful
For further assistance with correct Breast Shield sizing
and comfort, please see a lactation consultant or
breastfeeding specialist
Elvie Stride will not work when connected to the
charger; always disconnect Elvie Stride from the
charger and close the Charging Port
If stored at minimum or maximum storage
temperature (see Product specifications), when
removing from storage, please allow 24 hours
for the pump to reach normal operating
temperature before use
Do not attempt to reset the Hub during use
Take extra care when using Elvie Stride in the
vicinity of children
•
•
•
•
•
•
Please visit elvie.com for troubleshooting advice, including alerts,
warnings and how to factory reset Elvie Stride.
Please keep a copy of these instructions for future reference.
8
9
4. Getting ready
4.2 Taking Elvie Stride apart
To get the most from your pump, it’s really important to set
it up properly. This guide will show you how to assemble
your pump and how to customize it to fit your body.
1.
Remove the Cap. The Hub, Tubes and Cap must be
placed on a dry surface and kept away from water
Finger Grip
4.1 Charging
Plug in the Hub for five minutes to wake it up before first
use. The Hub will not turn on while it is charging. It takes
approximately two hours to fully charge the Hub,
although this can vary depending on your charging set up.
A full charge lasts approximately five 30 minute sessions.
Only use the Charging Cable provided in the box.
Battery low
Battery charging
Fully charged
2. Using the Finger Grips, pull the Cup Front away from
the Breast Shield
3.
Pull the Valve out of the Breast Shield. Then remove
the Diaphragm
Charge immediately after finishing your pumping session
if low battery is indicated.
Tip: Press the Mode button when the Hub is off;
the Intensity Lights will show how much battery is left.
Tip: Close the Charging Port before use to ensure the
Hub is as discreet as possible.
10
11
4.3 Cleaning
Before first use
Elvie Stride is not provided sterile. It must be cleaned and
sanitized before first use. Always disassemble the
components before cleaning or sanitizing. For additional
cleaning guidelines see the Center for Disease Control
website – https://www.cdc.gov/healthywater/hygiene/
healthychildcare/infantfeeding/breastpump.html
1.
Before first use, remove the Cup Seal by peeling it out
of the groove on the side. During normal cleaning this
Cup Seal can stay in place
2.
To replace, stretch the Cup Seal over the outer rim of
the Cup Front. Make sure it goes on with the ridges
facing outwards. Press along the groove, checking
that it is snugly in place all the way around
Non-washable components
Charging Port
Hub
Cap Seal
Cover
Clip
Short Tube
(for the Cups)
Tube Splitter
Tube Splitter
Stopper
Charging Cable
Hub Connector
Long Tube (for the Hub)
12
The Hub, Cap, Tubes, Tube Splitter, Cover and Clip are
non-washable components and should be kept dry.
They must not be microwaved. They can be wiped clean
with a damp cloth, but should not be submerged in water.
If the tubes are moldy, discard and replace immediately.
Washable components
Breast Shield
Stopper
Diaphragm
Cup Front
Cup Seal
Valve
Cap
Cleaning washable components that come into contact
with milk, as soon as possible after pumping, prevents the
buildup of dry milk residue. Residue can cause the growth
of bacteria that may be harmful to you and your baby.
Cleaning (before first use and after every use)
1.
Rinse in cold, clear water. Do not place the parts
directly in the kitchen sink for rinsing and washing.
Use a dedicated wash basin and brush for infant feeding
2. Wash in warm water using mild dish washing soap
3. Rinse with cold, clear water for 10 to 15 seconds
OR
Place on the top shelf of the dishwasher
13
Sanitizing (before first use
and subsequently once daily)
1. Sanitize parts in boiling water for five minutes
OR
Suitable for microwave, steam or cold water sanitization.
We do not recommend microwave or steam sanitizing for
more than five minutes.*
*Always refer to the manufacturer’s instructions
Drying
Place parts on a clean surface and air dry completely
before assembly.
4.4 Breast Shield sizing
Elvie Stride comes with two (24 mm) Breast Shields.
If needed (21 mm ) or (28 mm) Breast Shields are
available to purchase separately.
The Breast Shield creates a seal between your nipple and the
pump, and it is therefore important it fits well.
To check your size:
1.
2.
3.
Put the Breast Shield on with the sizing symbol
facing upwards, and place your nipple in the
center of the fit lines
The fit lines should align with the outside of your nipple
To comfortably pump on both sides, repeat this process
for both nipples to ensure you have the correct Breast
Shield size for each nipple
Nipple Tunnel
Elvie Stride Breast Shield
Breast Shield too small
Breast Shield correct fit
Breast Shield too big
Too small – buy (28 mm)
Too big – buy (21 mm)
14
15
Breast Shield correct fit
4.5 Assembling Elvie Stride
Wash hands thoroughly before you begin. Once the parts
have been cleaned and sanitized, make sure they are dry
and not moldy before putting them together. Pay extra
attention to the Diaphragm and ensure it is completely dry.
1.
Attach the Cover and Clip. Slide the Hub into the
Cover, ensuring the hole for the Hub Connector is
aligned with the hole on the Cover. Push the short
end of the Clip through the slot, and pull through
2. Push the Hub Connector firmly into the Hub,
ensuring that it is fully inserted
3.
Push the Valve and Diaphragm
onto the Breast Shield
4. Use your fingers to work the Diaphragm rim over
the Breast Shield lip. Take a moment to check the
Diaphragm is sitting flush and is on securely
Breast Shield lip
Diaphragm rim
Frosted lip
5.
Push the Breast Shield and the Cup Front together
using the markings as a guide. Ensure that there is a
good seal all the way around. Check that there are
no gaps and that the Cup Seal is fully covered by the
frosted lip of the Breast Shield
6. Check that the Diaphragm is completely dry because
moisture can be sucked into the Hub. This will affect
performance. Push the Cap into the Cup Front
Tip: Take the Cup Front off and check that the Dia-
phragm is on correctly if:
•
•
You can’t get the Cup to push together fully
You can see the Cup Seal above the frosted lip
16
17
7.
Rotate the Cap when it’s in place for the most discreet fit
5. Using Elvie Stride
To help you to get the best performance from your pump,
this section will guide you through a pumping session.
5.1 Turning on Elvie Stride
Once fully assembled, press Power to turn the Hub on.
The Intensity Lights will begin to flash and will show
the intensity setting that Stimulation mode will start on.
You can adjust the intensity setting before you start
your session.
5.2 Aligning your nipple
We’re all different. No two nipples point in the same
direction. Correct nipple alignment in the Breast Shield
is the key to comfortable and efficient pumping.
Align the Breast Shield with the direction of your
nipples when you are putting it on.
To avoid discomfort, your nipple must be positioned
correctly in the Nipple Tunnel before pumping.
1. Use the markings on the Breast Shield to help align
your nipple when putting the Cup on
8. Check your nipple alignment through the open
Pour Hole. Close the Pour Hole using the Stopper
Pour Hole
9. Attach the Hub to your
clothing using the clip
4.6 Single-side pumping
To pump on one side, you only
need one Short Tube that connects
to one Cup. Remove the unused
Short Tube from the Tube Splitter.
Seal the opening with the Tube
Splitter Stopper to ensure consistent
suction on the one Cup in use.
Tip: Make sure the Tubes are not kinked or pinched flat
Breast Shield correctly aligned
Breast Shield incorrectly aligned
18
19
2. Bend forwards and hold your breast from underneath.
5.4 Starting your session
Bring the Cup to your breast, paying attention to the
direction of your nipple. You can use the markings
on the Breast Shield to help align your nipple
Once the Hub is turned on and the Cups are positioned in
your bra, press Play/Pause to start pumping. If you need to
pause pumping for any reason, press Play/Pause again.
5.5 Modes and intensity settings
Modes
Elvie Stride has two modes: Stimulation and Expression.
Elvie Stride will always start in Stimulation mode.
This is a faster pumping rhythm to stimulate milk let-down.
Elvie Stride will automatically switch to Expression mode
after approximately two minutes. You can also change
modes in the app or on the Hub using the Mode button.
When the Mode Light is illuminated, the pump is in
Expression mode. This is a slower, stronger pumping
rhythm for efficient milk expression.
Mode
Mode Light
3. Once the Cup is on, you can check your alignment
by removing the Stopper and adjusting so that your
nipple sits in the middle of the Nipple Tunnel.
Replace the Stopper before use
5.3 Finding the right in-bra fit
Elvie Stride is designed to be worn with your standard
nursing bra. You can use it in either a sitting or standing
position. Elvie Stride needs to be firmly pressed against
your breast. There should be no gaps between the Cups
and your breasts.
Every bra has a different level of support, so make sure to
get the pressure and fit right before each session. This is
important because it can have an impact on milk volumes.
20
21
Intensity settings
5.7 Ending your session
1. While leaning forward, press Play/Pause to stop
pumping. Turn off the pump by pressing and
holding Power
2. Unclip your bra and use your finger to break the seal
around your nipple to avoid nipple damage
3. Remove the entire Cup from your bra
4. Remove the Cap from the Cup
5.
The Cup can be laid flat on a dry surface with the
Nipple Tunnel facing up before decanting if required
6. Unplug and rotate the Stopper to decant your milk
Pour milk out as shown below, through the side of
7.
the Pour Hole
8. Refer to the Cleaning section of this booklet for
cleaning and sanitizing instructions
Elvie Stride has ten intensity settings in Stimulation mode
and ten intensity settings in Expression mode. This means
you can adjust the pump to find a setting that feels
comfortable and works efficiently in both Stimulation and
Expression modes. Once you can feel the suction on your
nipples, use and to adjust the intensity to find your
preferred setting in both modes. The Intensity Lights will
illuminate to show your chosen setting.
You can save the intensity settings that you would like your
pump to start in for both Stimulation and Expression mode
by using the Personalize feature in the Pump with Elvie
app. The app is free to download in the Apple App Store
or Google Play Store.
Tip: A higher intensity setting does not always mean a higher
volume of milk. Putting your nipple under excess stress
or pumping if you are in pain can reduce milk production.
Tip: Make sure the Tubes are not kinked or pinched flat.
5.6 Automatic functions
•
The Hub will automatically switch from Stimulation
mode to Expression mode after two minutes
• When the Hub is pumping, it will automatically pause
after 40 minutes. It is recommended that you leave
Elvie Stride for 60 minutes before using it again
• When the Hub is paused, it will automatically turn off
if a button has not been pressed for five minutes
•
•
The Hub will automatically turn off if the battery
is empty
The Hub will automatically turn off if a technical
error occurs
22
23
Tip: Leaning forward when you pause or stop your session
helps the milk drain from the Nipple Tunnel into the Cup.
•
•
•
•
•
•
•
5.8 Storing your milk
Do not store your milk in the Cup. Pour your milk
into a sealed container of your choice. Before storage,
label with date and time, and immediately place
in a fridge, freezer, or cooler bag with ice packs
While you are preparing to pour your milk the Cup
can be laid flat on a dry surface with the
Nipple Tunnel pointing up
For information on storing your breast milk, refer to
https://www.cdc.gov/breastfeeding/recommendations
/handling_breastmilk.htm
5.9 How to store Elvie Stride
Short-term storage
Recharge immediately after finishing your pumping
session if the Battery Light is on
Between sessions, please store your Elvie Stride out
of direct sunlight and ensure the washable parts are
clean and dry. Keep out of reach of children
Tip: It’s important that the components are kept dry in
storage because mold may develop if moisture is present.
Long-term storage
The washable parts will require cleaning and drying
before long-term storage and should be stored away
from direct sunlight to avoid discoloration
If stored at minimum or maximum storage temperature
(see Product specifications), please allow 24 hours for
the pump to reach normal operating temperature
before use after removing it from storage
6. Troubleshooting
Alerts and warnings
Intensity Lights flashing – Elvie Stride is paused
Battery Light flashes red four times – battery empty
All Intensity Lights illuminated –
maximum intensity level reached
All lights flash then turn off – technical error
(Contact Customer Care)
Factory reset
To perform a factory reset:
Turn Elvie Stride on
Press and hold both
simultaneously for five seconds
Play/Pause and Intensity Lights will flash while
Elvie Stride is resetting
All lights and Elvie Stride will then turn off
Re-attaching the Tube into the Cap
Tube Port
•
•
•
•
1.
2.
3.
4.
1.
2.
Insert the Short Tube
into the Cap
Push the Short Tube
onto the Tube Port
3. Once secure, ensure there
are no kinks or bends in tubes
24
25
7. Warranty
Elvie Stride Limited Warranty for the United States
At Chiaro Technology Limited (“Chiaro”), we stand behind the Elvie Stride. The
Elvie Stride is backed by a limited manufacturer’s warranty against any defects
in materials and/or workmanship for a period of two (2) years for the Hub and
ninety (90) days for all other components. These warranty periods shall run
from the date of original purchase. Because Chiaro cannot control the quality
of products sold by unauthorized sellers, this limited warranty applies only to
original purchasers of the Elvie Stride that were purchased from Chiaro or a
Chiaro authorized seller in the United States, unless otherwise prohibited by
law. Chiaro reserves the right to reject warranty claims from purchasers for
the Elvie Stride purchased from unauthorized sellers, including unauthorized
Internet sites. The warranty is also limited to the original, end-user purchaser.
This warranty does not cover cosmetic deterioration or damage caused
by general wear and tear, physical or natural destruction, accident, misuse,
neglect, alteration to the product or other external causes.
Any warranty claims must be supported with reasonable evidence, including
proof of date of purchase, alongside these warranty conditions. Chiaro
reserves the right to a reasonable period of investigation to establish the cause
of the defect. If you wish to make a warranty claim, please contact Chiaro at
questions@elvie.com and/or 508 300-9989 and have information available
regarding where and when you purchased your Elvie Stride. If your request is
approved, we will provide further guidance relating to providing your proof of
purchase or any returns. Please note that, if applicable, you are responsible for
costs incurred in mailing your product and/or proof of purchase. Chiaro will
repair or replace a defective Elvie Stride that is covered by this warranty. In
the event that Chiaro decides to provide a replacement, any replacement
will not renew or extend the duration of this warranty. There are no
warranties which extend beyond those stated herein. Any implied warranties
that may be applicable to the Elvie Stride, including implied warranties of
merchantability or fitness for a particular purpose, are limited in duration to
the duration of this warranty. Some States do not allow limitations on how
long an implied warranty lasts, so the above limitation may not apply to you.
Under no circumstances shall Chiaro be liable for any special, incidental, or
consequential damages based upon breach of this limited warranty, breach of
contract or strict liability. Some States do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation or exclusion
may not apply to you. This warranty gives you specific legal rights, and you
may also have other rights which vary from State to State.
If you have any questions about whether a seller is authorized,
call us at 508 300-9989 or email us at questions@elvie.com
Instructions for return
We will provide you with a Return Merchandise Authorization number, which
must be displayed on the outside packaging. Please keep your proof of purchase
in the event that you need to contact Elvie Customer Care for warranty services.
26
8. Product specifications
Technical specifications
On/Off
Mode
Increase intensity
Decrease intensity
Do not microwave
II
Play/Pause
Consult instructions for use
Manufacturer
Date of manufacture
Do not dispose the device together with unsorted municipal
waste (in accordance with the local regulations)
Compliance with international requirements for protection
from electric shock. (Type BF applied parts)
IP22
Protection against entrance of solid foreign objects and
against harmful effects due to the entrance of water
Manufacturer has taken all necessary measures to ensure that
the product complies with applicable safety legislation for
distribution within the European Community
SN
LOT
Serial Number
Lot Number
Direct Current
Vacuum range
-35 to -300 mmHg
Power
5 v DC, 1.5 A max
Battery capacity and type
2300 mAh Li-ion rechargeable
Bluetooth info
Bluetooth V4.2 (Bluetooth Low
Energy) Range up to 10m
Operating temperature
+5 °C to +30 °C/ +41 °F to +86 °F
Operating humidity
Ambient pressure
Use life
15 to 90% RH
90 to 106 kPa
500 hours
27
Electromagnetic compatibility (EMC) Advice
This device complies with part 15 of the FCC rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy,
and if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more
of the following measures:
i) Reorient or relocate the receiving antenna
ii) Increase the separation between the equipment and receiver
iii) Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected
iv) Consult the dealer or an experienced radio/TV technician
for help
FCC Radiation Exposure Statement: This equipment complies
with FCC radiation exposure limits set forth for an uncontrolled
environment. This transmitter must not be co-located or operating
in conjunction with any other antenna or transmitter.
Caution: The user is cautioned that changes or modifications not
expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
Guidance and manufacturer’s declaration –
electromagnetic emissions
Elvie Stride is intended for use in a Home Healthcare Environment.
The Elvie Stride breast pump product is suitable for use in a specific
electromagnetic environment outlined below. The user of this
product should assure that it is used in such an environment.
Emission Tests
Compliance
RF Emissions
CISPR 11
Group 1
Electromagnetic
environmental guidance
The Elvie Stride uses RF
energy only for its internal
function. Therefore, its RF
emissions are very low
and are not likely to cause
any interference in nearby
electronic equipment.
The Elvie Stride is suitable
for use in all establishments,
including domestic
establishments and those
directly connected to the
public low voltage power
supply network that
supplies buildings used
for domestic purposes.
RF emissions
CISPR 11
Class B
Harmonic emissions Not Applicable
IEC 61000-3-2
Voltage fluctuations / Not Applicable
flicker emissions
IEC 61000-3-3
WARNING: This device should not be used adjacent to or stacked
with other equipment. And if adjacent or stacked use is necessary,
this device should be observed to verify normal operation in the
configuration in which it will be used.
28
29
Guidance and manufacturer’s declaration –
electromagnetic immunity
Guidance and manufacturer’s declaration –
electromagnetic immunity
The Elvie Stride breast pump product is suitable for use in a specific
electromagnetic environment outlined below. The user of this product
should assure that it is used in such an environment. The Elvie Stride
breast pump was tested for immunity to electromagnetic disturbances
and passed using the following criteria:
1) No noticeable change in the operation of the breast pump
signifying maximum vacuum pressure is exceeded (-300 mmHg)
or cycle speeds are degraded.
2) During charging, the pump did not turn on and start operating.
Immunity test IEC 60601 test level Compliance level Electromagnetic
environment guidance
Electrostatic
discharge
(ESD) IEC
61000-4-2
+/- 2kV, +/-
4kV, +/- 6kV,
+/- 8kV contact
discharge
+/- 2kV, +/-
4kV, +/- 6kV,
+/- 8kV contact
discharge
+/- 2kV, +/- 4kV,
+/- 6kV, +/- 8kV,
+/- 15 kV air
discharge
+/- 2kV, +/- 4kV,
+/- 6kV, +/- 8kV,
+/- 15 kV
air discharge
30 A/m, 50
or 60 Hz
30 A/m, 50
or 60 Hz
Power
frequency
(50/60 Hz)
magnetic
field IEC
61000-4-8
Floors should be
wood, concrete
or ceramic tile.
If floors are
covered with
synthetic
material, the
relative
humidity should
be at least 30%.
It may be
necessary to position
the breast pump
further from sources
of power frequency
magnetic fields
or to install
magnetic shielding.
The power frequency
magnetic field
should be
measured in the
intended installation
location to assure that
it is sufficiently low.
30
Immunity test IEC 60601 test level Compliance level
Radiated
RF
IEC
61000-4-3
10 V/m
(minimum)
80 MHz –
2,7 GHz
80 % AM
at 1 kHz
10V/m
(minimum)
Electromagnetic environment guidance: Portable and mobile RF
communications equipment should be used no closer to any part
of the breast pump, including cables, than the recommended separation
distance calculated from the equation applicable to the frequency
of the transmitter. Recommend separation distance:
d = 1,2√P
d = 1,2√P 80 MHz - 800 MHz
d = 2,3√P 800 MHz - 2.7 GHz
Where P is the maximum output power rating of the transmitter in watts
(W) according to the transmitter manufacturer and d is the recommended
separation distance in metres (m). Field strengths from fixed RF
transmitters, as determined by an electromagnetic site survey, a should
be less than the compliance level in each frequency range. Interference
may occur in the vicinity of equipment marked with the following symbol.
Note 1: At 80 MHz and 800 MHz, the higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic
propagation is affected
A. Field strengths from fixed transmitters, such as base stations for radio
(cellular/cordless) telephones and land mobile radios, amateur radio,
AM and FM radio broadcast and TV broadcast cannot be predicted
theoretically with accuracy. To assess the electromagnetic environment
due to fixed RF transmitters, an electromagnetic site survey should be
considered. If the measured field strength in the location in which the
breast pump is used exceeds the applicable RF compliance level above,
the breast pump should be observed to verify normal operation.
If abnormal performance is observed, additional measures may be
necessary, such as re-orienting or relocating the breast pump.
B. Over the frequency range 150 kHz to 80 MHz, field strengths
should be less than 10 V/m.
31
WARNING: Portable RF communications equipment (including
peripherals such as antenna cables and external antennas) should be
used no closer than 30 cm (12 inches) to any part of Elvie Stride including
cables specified by the manufacturer. Otherwise, degradation of the
performance of this equipment could result
Band
(MHz)
Service
Modulation
Max
Power
(W)
Distance
(m)
Immunity
Test Level
(V/m)
380-
390
704-
787
800-
900
TETRA 400
Pulse
1.8
0.3
27
430-
470
GMRS 560,
FRS 460
FM
2
0.3
28
LTE Band 13, 17
Pulse
0.2
0.3
9
GSM 800/900;
TETRA 800; iDEN
820; CDMA 850;
LTE Band 5
Pulse
0.3
28
1700 -
1990
GSM 1800; CDMA
1900; GSM 1900;
DECT; LTE Band
1,3,4,25; UMTS
2400 -
2570
Bluetooth, WLAN,
802.11 b/g/n, RFID
2450. LTE Band 7
Pulse
0.3
28
Pulse
0.3
28
5100 -
5800
WLAN 802.11 a/n
Pulse
0.2
0.3
9
2
2
2
Transport, storage and disposal
Transport
While traveling, use the Charging Cable provided and pair
with the appropriate USB power source for your current
location. Please check with the airline prior to travel for
advice on carrying and using Elvie Stride while flying.
Temperature: -20 °C to +60 °C / -4 °F to +140 °F
Relative humidity: 15 to 90%
Storage
Temperature: -20 °C to +60 °C / -4 °F to +140 °F
Relative humidity: 15 to 90%
Ambient pressure: 90 to 106 kPa
Disposal
Elvie Stride contains a Li-ion rechargeable battery. Please
dispose of the Hub at a designated collection point for the
recycling of waste electrical and electronic equipment.
The appropriate disposal of Elvie Stride will help conserve
natural resources and ensure that it is recycled in a manner
that protects human health and the environment.
For more information about where you can drop off your
waste for recycling, please contact your local authority or
where you purchased your product.
32
33
34
35
elvie.com
Manufactured and distributed by Chiaro Technology Limited
Model number: EB01
Document number: AW-000027
Revision number: 7
28
36
1 | Location Label | ID Label/Location Info | 277.53 KiB | September 10 2021 |
ITEM NO.
PART NUMBER
1
000635
DESCRIPTION
Puck Assembly
QTY.
1
ZONE
REV.
DATE
APPROVED
REVISIONS
DESCRIPTION
4
5
6
7
8
9
CHILD PARTS MODIFIED. TOOL MOD FOR EV
2020-11-04
CHILD PARTS MODIFIED. MARKINGS UPDATED . TOOL MOD FOR DV
2020-12-23
CHILD PARTS MODIFIED. TOOL MOD FOR DV. MARKINGS UPDATED
2021-02-03
CHILD PARTS MODIFIED. TOOL MOD FOR PV
CHILD ASSEMBLY MODIFIED FOR PV
CHILD PART MODIFIED, SILENCER UPDATE
2021-04-07
2021-05-25
2021-07-30
DT
DT
DT
DT
DT
DT
9
10.18 ±0.20
UNIQUE DEVICE
SERIAL NUMBER
GENERATED AT
END-OF-LINE
FUNCTION TEST
SCANNABLE BARCODE OF
UNIQUE DEVICE SERIAL NUMBER
Z
DETAIL Z
SCALE 2 : 1
NOTE:
REFER TO 000854 PUCK MARKINGS - ARTWORK REV[LATEST].AI
FOR ARTWORK AND COLOUR SPEC.
DIMENSIONS FOR GUIDANCE ONLY, 3D CAD MODEL IS MASTER,
ARTWORK SHOULD BE CENTRAL TO PART
1
0
2
.
0
±
9
0
.
5
= CHANGE ICON
= KEY CHARACTERISTIC
= LOW CPK CRITICAL FIT
1. 3D CAD MODEL IS MASTER.
2. THIS DOCUMENT IS THE SOLE PROPERTY OF CHIARO
TECHNOLOGY LTD. & SHOULD NOT BE USED OR
DISTRIBUTED WITHOUT PRIOR WRITTEN CONSENT.
PROJECTION:
THIRD ANGLE
DO NOT SCALE DRAWING
REVISION: 9
DEBUR AND
BREAK SHARP
EDGES
NAME
DATE
TITLE:
CHIARO TECHNOLOGY LTD
Puck Markings Laser Print
DRAWN
CHECKED
APPROVED
MATERIAL:
FINISH:
OB
-
DT
2020-03-03
-
30/07/2021
N/A
N/A
DWG NO.
COLOUR:
SEE ARTWORK FILE
000854
A3
WEIGHT: N/A
SCALE:1:2
SHEET 1 OF 1
1 | Authorization Letter | Cover Letter(s) | 140.66 KiB | September 10 2021 |
2nd Floor, 63-66 Hatton Garden, London - EC1N 8LE
Tel: +44 (0) 203 745 5201
23rd August 2021
This is to certify that Chiaro Technology Ltd hereby authorises UL International (UK)
Ltd. to act as the TCB for the application of the Elvie LIMA Breast Pump, Model
EB01, FCC ID: 2AEHI-EB01to the FCC.
We certify that we are not subject to a denial of Federal benefits, that include FCC
benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §
862 because of a conviction for possession or distribution of a controlled substance.
See 47 CFR 1.2002(b) for the definition of a "party" for these purposes.
Telecommunication Certification Body
UL International (UK) Ltd.
Units 1-3, Horizon
Wade Road
Kingsland Business Park
Basingstoke
Hampshire
RG24 8AH
United Kingdom
Subject: Authorisation Letter
To whom it may concern
Yours faithfully,
____________________
Alastair Traquair
Head of Quality
email: alastair.traquair@chiaro.co.uk
www.chiaro.co.uk
Registered company name - Chiaro Technology Ltd
Company No. 08502405 registered in England and Wales
VAT Reg. GB 172 6300 28
1 | Permanent Confidentiality Letter | Cover Letter(s) | 96.73 KiB | September 10 2021 |
2nd Floor, 63-66 Hatton Garden, London - EC1N 8LE Tel: +44 (0) 203 745 5201 23rd August 2021 Telecommunication Certification Body UL International (UK) Ltd. Units 1-3, Horizon Wade Road Kingsland Business Park Basingstoke Hampshire RG24 8AH United Kingdom Pursuant to Sections 0.457(d) and 0.459 of CFR 47 , Chiaro Technology Ltd request that the following information, provided to support the FCC application for the Elvie LIMA Breast Pump, Model EB01 FCC ID: 2AEHI-EB01 be held permanently confidential:
Schematics Block Diagrams Operational Description The above material contains trade secrets not customarily released to public that are judged to have the potential to cause detriment to the applicant and provide unjustified benefits to its competitors. This information should not be available for public disclosure for an indefinite period of time. Yours faithfully, ____________________ Alastair Traquair Head of Quality email: alastair.traquair@chiaro.co.uk www.chiaro.co.uk Registered company name - Chiaro Technology Ltd Company No. 08502405 registered in England and Wales VAT Reg. GB 172 6300 28
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2021-09-10 | 2402 ~ 2480 | DTS - Digital Transmission System | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2021-09-10
|
||||
1 | Applicant's complete, legal business name |
Chiaro Technology Ltd
|
||||
1 | FCC Registration Number (FRN) |
0024470239
|
||||
1 | Physical Address |
2nd Floor, 63-66 Hatton Garden
|
||||
1 |
2nd Floor
|
|||||
1 |
London, N/A
|
|||||
1 |
United Kingdom
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@ul.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
2AEHI
|
||||
1 | Equipment Product Code |
EB01
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
D****** S****
|
||||
1 | Title |
Co Head of Operations
|
||||
1 | Telephone Number |
+44(0********
|
||||
1 | Fax Number |
+44(0********
|
||||
1 |
d******@chiaro.co.uk
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Chiaro Technology Ltd
|
||||
1 | Name |
A**** T********
|
||||
1 | Physical Address |
2nd Floor
|
||||
1 |
Bristol, BS2 8PE
|
|||||
1 |
United Kingdom
|
|||||
1 | Telephone Number |
+4479********
|
||||
1 |
A******@chiaro.co.uk
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DTS - Digital Transmission System | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Elvie LIMA Breast Pump, Model EB01 | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power is conducted. This equipment complies with FCC RF portable radiation exposure limits set forth for an uncontrolled environment. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
UL LLC
|
||||
1 | Name |
S****** T********
|
||||
1 | Telephone Number |
919 5********
|
||||
1 |
s******@ul.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 | 0.0024000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC