ZBM-2400 User Manual User manual ZBM-2400 Plug in type ZigBee module ATCB ID: ATCB012366 FCC ID: CO9ZBM2400 IC: 10396A - ZBM2400 Chilin Electronics co ltd. V1.0.1 Page i ZBM-2400 User Manual Content 2 1 3 4 5 Introduction ................................................................................................................................. 1 1.1 Scope................................................................................................................................... 2 ZBM-2400 specifications............................................................................................................ 3 2.1 Pin assignment .................................................................................................................... 4 2.2 Hardware characteristics & specifications ........................................................................... 6 ZBM-2400 Maximum rating ........................................................................................................ 7 ZBM-2400 Normal working condition ....................................................................................... 8 ZBM-2400 Communication protocol ......................................................................................... 9 5.1 Transparent transmission mode .......................................................................................... 9 5.2 API mode ............................................................................................................................. 9 Related terms and abbreviation .............................................................................................. 10 ZBM-2400 Module mechanic specifications........................................................................... 11 7.1 ZBM-2400 size................................................................................................................... 11 7.2 Re-flow temperature specifications.................................................................................... 12 7.3 Recommend soldering....................................................................................................... 12 Example of installation............................................................................................................. 13 8 9 Warning...................................................................................................................................... 14 6 7 Chilin Electronics co ltd. V1.0.1 Page ii ZBM-2400 User Manual 1 Introduction ZBM-2400 is a ZigBee module that comply with IEEE802.15.4 standardimplement with ZigBee protocol & communication APIits industrial quality suitable for related wireless transmission application low powermesh networkingeasy to use and user friendlyZBM-2400 module was designed at 2.4GHz frequency bandusing DSSS frequency modulationstable and meets EMC & EMI standards The ZigBee modules FCC ID: CO9ZBM2400 & IC ID:10396A-ZBM2400 was shown on the label, if the module is put inside a product, the outer casing should have an exterior label indicated:
Contains FCC ID: CO9ZBM2400 & IC ID:10396A-ZBM2400
Frequency range2.400GHz ~ 2.480GHztotal 16 channels
Receiver sensitivity: -104dBm
Max. Out put power: +6dBm
Max. transmission range: 1200 metersLOS
Low consuming powerReceiving at 34 mAtransmitting at170 mA @ +6 dBmsleep mode1uA
Supply voltage range2.0 -3.6 VDC
Digital signal strength indication: RSSI
Working temperature range20 ~ +65 C
Strong Mesh networking
Transmission parameter setting: OTA
CSMA-CA anti-collisions detection
Transparent transmission Chilin Electronics co ltd. V1.0.1 Page 1 ZBM-2400 User Manual 1.1 Scope This manual describes the ZBM2400 specification, parameterspin assignmentcommunication protocolinstruction setsin order to guide the user how to design a target PCB Chilin Electronics co ltd. V1.0.1 Page 2 ZBM-2400 User Manual 2 Specification of ZBM-2400 Item Data Remark Working frequency Max. transmission power Lowest receiving sensitivity Transmission range Transmission Modulation rate type Transmission current Receiving current Sleeping current Operation voltage Interface 2.400~2.480GHz 6dBm
-104dBm 1200m 1200bps~115200bps O-QPSK
<175mA@20dBm
<35mA
<1uA 2.0~3.6V UART Connector pins Dual 11Pin single line Antenna Size Working temperature Working humidity MCU FLASH MCU RAM ADC ports u.FL/Chip 32mm24.3mm 20 ~ + 65 C 10%~90%
256K 8K 2 ports DIO 7 channel PER<0.1%
LOS TTL level 2.0mm gauge relative Reserved Reserved Chilin Electronics co ltd. V1.0.1 Page 3 Hardware parameters ZBM-2400 User Manual 2.1 Pin assignment 1 PANC ZM100 Pin no. Mark Type Description 1 2 3 4 5 6 ADC0/P0.0 ADC1/P0.1 P2.4 P2.3 P2.2 P2.1 AI AI DIO DIO DIO DIO Voltage I/P0V~VDD Voltage I/P0V~VDD Reserved Reserved Reserved Reserved Chilin Electronics co ltd. V1.0.1 Page 4 ZBM-2400 User Manual Pin no. Mark Type Description 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 P2.0 P1.7/MISO P1.6/MOSI P1.5?SCLK P1.4/CSn P1.1/SDA GND P1.0/SCL P0.7 P0.6 P0.5/RTS RST P0.4/CTS P0.2/RX P0.3/TX VDD DO DO DO DO DO DIO G DIO DIO DIO DIO DI DIO DI DO P To LEDtransmission fail indication To LEDtransmission indication To LEDReceiver indication To LEDSignal strength indication To LEDworking status Reserved Reserved Reserved Reserved Reserved Reserved Resetlow active Reserved UART receive for module3.3V UART transmit from module3.3V Input power3.3V Abbreviations list DI=Digital Input. DO=Digital Output DI/O=Digital bi-directional input/output pin. DO/D=Digital Open Drain. AI=Analog input pin AO=Analog output pin RF=RF signal I/O pin P=Power pin G=Ground pin Chilin Electronics co ltd. V1.0.1 Page 5 ZBM-2400 User Manual 2.2 Hardware characteristics & specifications Serial port Baud rate Parity check Max. Series length Overhead XOR Support command mode Max. number of nodes Network Scope of node number 1200~115200 N/8/1 102 characters 5 1-character XOR API instruction mode API data mode Transparent mode 65536 (0 ~ 65535) 0 ~ 65533
(0: for Master 65534: Data return 65535: broadcast) Chilin Electronics co ltd. V1.0.1 Page 6 ZBM-2400 User Manual 3 ZBM-2400 Maximum rating Item Any port I/P voltage Max. VCC to GND current Any port max. I/P current Any port max. OI/P current Storage temperature Condition Minimum Type Max. Unit
-0.3
-55 3.6 500 100 100
+125 V mA mA mA C
*NoteDo not exceed the max. rating listed above, otherwise permanent damage will be occurred. Warning! ESD sensitiveproper preparation for anti-ESD is required when installing the module Chilin Electronics co ltd. V1.0.1 Page 7 ZBM-2400 User Manual 4 ZBM-2400 Normal working condition Item Supply voltage Working temperature Working humidity Conditi on Min Typical Max. Unit 2.0
-40 10%
3.3 3.6 85 90%
V C Warning! Lower supply voltage will cause lower O/P power. Chilin Electronics co ltd. V1.0.1 Page 8 ZBM-2400 User Manual 5 ZBM-2400 Communication protocol 5.1 Transparent transmission mode To enter transparent mode command AT command To mode parameter Return value
- - -N-
Transparent mode To API mode N = 0 ~ 65533, 65535, in decimal N/A N/A N/A When use this mode, all the characters send from master will be received from client. 5.2 API Mode API mode, also called binary mode, its command include:
Head
(1) LQI
(1) Destination
(2) Load length
(1) load
(0 102) Check sum
(XOR)
(1) These command should be send from target CPU, for master clocks system transmission, destination will be 65535(0xFFFF) means broadcastLoad will be time and date information. Chilin Electronics co ltd. V1.0.1 Page 9 ZBM-2400 User Manual 6 Related terms and abbreviation Analog to Digital Converter Automatic Meter Reading Cipher Feedback Mode ADC AMR CFB CMOS Complementary Metal Oxide Semiconductor Central Processor Unit CPU Data Encryption Standard DES Federal Communication Committee FCC Frequency Shift Keying FSK Integrated Development Environment IDE Intermediate Frequency IF Industrial Scientific Medical ISM Interrupt Service Routine ISR Line of Sight LOS Loop Filter LPF Link Quality Indicator LQI LSB Least Significant Bit MAC Medium Access Layer MSB Most Significant Bit Printed Circuit Board PCB Physical Layer PHY POR Power On Reset Random Access Memory RAM Radio Frequency RF RSSI Received Signal Strength Indicator Real-Time Clock RTC Receive RX SFR Special Function Register SPI Serial Peripheral Interface SRAM Static Random Access Memory SRD TQFP TX UART Universal Asynchronous Receiver/Transmitter Short Range Device Thin Quad Flat Pack Transmit Chilin Electronics co ltd. V1.0.1 Page 10 ZBM-2400 User Manual 7 ZBM-2400 Module mechanic specifications 7.1 ZBM-2400 Size Chilin Electronics co ltd. V1.0.1 Page 11 ZBM-2400 User Manual 7.2 Re-flow temperature specifications Recommend soldering base on IPC/JEDEC J-STD-020B standard Maximum Re-flow Temperature Ideal
(C) 215 Maximum
(C) 230 7.3 Recommend soldering Recommend soldering base on IPC/JEDEC J-STD-020B standard Johnson Alloy #806 Alloy Composition In/48Sn (e) Solidus
(C) 118 Liquids
(C) 118 Shear MPa Chilin Electronics co ltd. V1.0.1 Page 12 ZBM-2400 User Manual 8 Example of installation When put the module on the target PCB to perform ZigBee wireless transmission. Plug the module into socket with correct direction shown below. The DIP-SW #1 & #4 should be set to on position and DIP-SW
#2 & # 3 should be set to off position. Make sure no ESD discharge happened. ZigBee module Put the end up which chip antenna mounted. When power on, the green LED on the module will be flashing (power), then the red LED also flashing (data received), about 7 seconds later, the clock will be synced to master clock. Chilin Electronics co ltd. V1.0.1 Page 13 ZBM-2400 User Manual 9 Warning:
1. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 2. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Avertissement: (Franais) par le parti(la fte) responsable de la conformit pourraient annuler l'autorit de l'utilisateur pour oprer(exploiter) l'quipement. 1. Les changements(monnaies) ou des modifications non expressment approuves 2. Ce dispositif respecte la partie 15 des Rgles(Autorits) de FCC. L'opration est soumise aux deux conditions suivantes :
(1) Ce dispositif ne peut pas causer l'interfrence nuisible et (2) ce dispositif doit accepter n'importe quelle interfrence reue, y compris l'interfrence qui peut causer l'opration peu dsire. Chilin Electronics co ltd. V1.0.1 Page 14