Touch-it CE VESA / Front Panel glass 15,6 Operating Instructions Display and Touch Projected Capacitive Touch Easy Integration Ready For Use Touch-it CE 15,6 Operating Instructions Document No. Revision Date Address Telephone Fax E-Mail Internet Copyright PA10003599 01 23 Sep. 20 Christ Electronic Systems GmbH Alpenstrae 34 DE-87700 Memmingen
+49 (0)8331 8371 0
+49 (0)8331 8371 99 info@christ-es.de http://www.christ-es.de No part of this documentation may in any form be reproduced, copied or distributed by means of electronic systems without previous written per-
mission by Christ Electronic Systems GmbH. The translation into another language also requires a written permission. This documentation may be exclusively entrusted to the owner of the installation or to the employees of Christ Electronic Systems GmbH. Technical changes Christ Electronic Systems GmbH reserves the right to change specifica-
tions, executions and technical data held within this document without prior notice. Brand and product names are trademarks or registered trademarks of their respective owners. Trademarks Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 1 / 15 Aug. 2020, Revision 01 Document No.: PA10003599 Touch-it CE 15,6 Operating Instructions Table of Contents 1 1.1 1.2 1.3 1.4 2 2.1 2.2 2.3 3 3.1 3.2 3.3 3.4 3.5 4 4.1 4.1.1 4.2 4.3 Page General ..............................................................................................................................................3 Used Symbols .......................................................................................................................................... 3 General Pointers ..................................................................................................................................... 3 Cleaning .................................................................................................................................................. 4 Certification ............................................................................................................................................. 5 Technical Data ..................................................................................................................................6 System ....................................................................................................................................................... 6 Power Supply ........................................................................................................................................... 6 Mechanical & Environmental .............................................................................................................. 6 Commissioning ..................................................................................................................................7 Mounting Front Panel ............................................................................................................................... 7 Mounting VESA ......................................................................................................................................... 8 Technical Drawing ..................................................................................................................................... 9 Interfaces ............................................................................................................................................... 11 Power supply ......................................................................................................................................... 11 Software ...........................................................................................................................................12 Accessing the System ............................................................................................................................. 12 Accessing the System via SSH (Secure Shell) ............................................................................................................ 12 Rebuilding the Image ............................................................................................................................. 13 Recover the Delivery State ..................................................................................................................... 13 Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 2 / 15 Aug. 2020, Revision 01 Document No.: PA10003599 Touch-it CE 15,6 Operating Instructions 1 General 1.1 Used Symbols Symbol The following symbols are used in this instruction manual:
DANGER!
Denotes a direct threat of danger. Not observing this pointer may be life threatening or lead to serious injuries. CAUTION!
Denotes a possibly dangerous situation. Not observing this pointer can cause minor injuries or lead to material damages. INFORMATION!
Denotes application pointers and other useful information. 1.2 General Pointers INFORMATION This device was manufactured according to DIN EN ISO 9001 and left the factory in a perfect state. In order to maintain this state and to assure the safe operation, the user must consider the pointers and warning remarks, which are contained in this instruction manual. Please check immediately: Is the device damaged or is any equipment missing? (See chapter Commis-
sioning) In the case of defect please inform us immediately. CAUTION Intended Use These products are not designed, developed and produced for use, which pose fatal risks and dangers that may cause death, injuries, serious physical impairments or other loss, if no exceptional security measures are ensured. Thus there are limitations for use in the monitoring of nuclear reactions in nuclear power plants, flight control systems, air traffic control, in the control of mass transportation, medical life support systems and control of weapon systems. Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 3 / 15 Aug. 2020, Revision 01 Document No.: PA10003599 Touch-it CE 15,6 Operating Instructions If the device is used for other purposes or incorrectly operated, Christ Electronic Systems GmbH will not hold damages liable. Do not operate the touch-sensitive surface of the screen with any abrasive or sharp-edged objects. Protect the Touch-it Panel PC against caustic chemicals and long solar radiation. Never cover the Touch-it Panel PC completely or build it in a small closed and unvented housing. This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. DANGER In the case of damage of the device, shut it down and disconnect it immediately from the supply voltage. Disconnect every connection line and send it back to Christ Electronic Systems GmbH. Only the qualified staffs are allowed to carry out the repairs. The incorrect repair may lead to serious danger for the user. 1.3 Cleaning Use a humid and soft cloth with gentle soap suds to clean. INFORMATION CAUTION Do not clean the touch-sensitive surface of the monitor with detergents containing solvent or acid. Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 4 / 15 Aug. 2020, Revision 01 Document No.: PA10003599 Touch-it CE 15,6 Operating Instructions 1.4 Certification INFORMATION The device is certificated for operation in the US and Canada and comply with FCC regulations. The certification is available on request. Type label:
International Certification USA:
FCC (Federal Communications Commission) The device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause any harmful interference. (2) This device must accept any interference re-
ceived, including interference that may cause undesired operations. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE: This equipment has been tested and found comply with the limits of Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial environment. This equip-
ment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equi-
ment in a resident area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 5 / 15 Aug. 2020, Revision 01 Document No.: PA10003599 NXP i.MX6DL, DualCore 1 GHz 3D Vivante GC880 2D Vivante GC320 H.264, MPEG-4/XviD, MPEG-2, H.263 1 GB DDR3 RAM 4 GB eMMC FLASH Internal: MicroSD (up to 64GB) RTC Lithium Battery (optional) Linux Embedded 24 VDC 20%
15 W No Touch-it CE 15,6 Operating Instructions 2 Technical Data 2.1 System CPU Graphic Video Decoder Memory Storage CMOS Battery Operating System 2.2 Power Supply Supply Voltage Power Consumption Power Switch 2.3 Mechanical & Environmental Housing Front Housing Dimensions Weight Cooling Operating Temperature Storage Temperature Humidity Protection Class Certification Front Panel VESA Glass, Black Frame Aluminium / Silver 403.2 mm x 252.6 mm x 52.4 mm 403.2 mm x 252.6 mm x 68.0 mm 3.8 kg 3.5 kg Passive 0 ~ 50 C
-10 ~ 70 C 5 ~ 80 % (non condensing) IP65 (IP20 rear) IP65 CE, EN55032 Class A, EN55024, UL, FCC Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 6 / 15 Aug. 2020, Revision 01 Document No.: PA10003599 Touch-it CE 15,6 Operating Instructions 3 Commissioning 3.1 Mounting Front Panel The variant Touch-it CE Front Panel is designed for front mounting. Each Front Panel has its own cut-out drawing. To clamp the Front Panel into the cut-out you can use the pre-assembled fasting clamps. Turn fasting clamp to the side Screw in the setscrew CAUTION For the best installation result the use of all pre-assembled fasting clamps is highly recommended. De-
pending on individual installation circumstances a new IP rating may be considered. Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 7 / 15 Aug. 2020, Revision 01 Document No.: PA10003599 Touch-it CE 15,6 Operating Instructions 3.2 Mounting VESA The variant Touch- it CE VESA is designed for VESA MIS-D, 75, mounts. Suitable mounting variants are:
VESA Desk Stand Arm Mounting System VESA-SA75 Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 8 / 15 Aug. 2020, Revision 01 Document No.: PA10003599 Touch-it CE 15,6 Operating Instructions 3.3 Technical Drawing FRONT PANEL E702613 Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 9 / 15 Aug. 2020, Revision 01 Document No.: PA10003599 Touch-it CE 15,6 Operating Instructions VESA E702617 PA10004391 Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 10 / 15 Aug. 2020, Revision 01 Document No.: PA10003599 Touch-it CE 15,6 Operating Instructions Interfaces 3.4 USB Ethernet Communication Power Connector 2 x USB 2.0 1 x 100 Mbit Ethernet 1 x RS-232, 1 x RS485, 1 x CAN
(one connector) Phoenix 3-pol MC 1,5/ 3-ST-3,5 BK INTERFACES COM Connector Pinning Pin 1 2 3 4 5 6 7 8 Function GND GND RS485_P RS232_TX RS232_RX RS485_N CAN_Low CAN_High Description Ground Ground RS485 Positiv RS232 Transmitter Signal RS232 Receiver Signal RS485 Negative CAN Low Signal CAN High Signal 3.5 Power supply The power supply was part of the safety and EMC certification and it is necessary to use this kind or a similar one in respect of the technical datas:
Type of power supply Input voltage Output voltage Max. output current Power Connector FSP060-DAAN2 100-240Vac 24Vdc 2,5A Phoenix 3-pol MC 1,5/ 3-ST-3,5 BK Changing the type of the power supply without our permittion, may cause problems with the conformitiy of the certifications and therefore is not guaranteed The device is only permitted to be supplied with a SELV/PELV power supply or with safety extra lowvoltage (SELV) per EN 62368-1 Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 11 / 15 Aug. 2020, Revision 01 Document No.: PA10003599 Touch-it CE 15,6 Operating Instructions 4 Software The highly customized software consists of:
Bootloader: Das U-Boot Linux (poky/ces-fb based) Kiosk browser based on chromium The system is configured to load a pre-set webpage and offer no additional method of configuration and does not allow any other use for the operator. The system admin can configure the system via ssh. 4.1 Accessing the System 4.1.1 Accessing the System via SSH (Secure Shell) SSH can be used for encrypted login over the network or for encrypted file transfer between your PC and the device. ssh root@<IP address of the device>
Example:
user@linux-pc:~$ ssh root@10.15.15.16 The authenticity of host '10.15.15.16 (10.15.15.16)' can't be established. RSA key fingerprint is 54:09:6d:2e:c6:b3:09:06:8d:4b:a8:0c:a8:7d:64:4a. Are you sure you want to continue connecting (yes/no)? yes Warning: Permanently added '10.15.15.16' (RSA) to the list of known hosts. root@10.15.15.174's password:
root@pixidl:~#
SSH uses port 22. User name and password are the same as for serial (RS232) login. User: root Password: root123 Because the IP address of the device is set to DHCP, nmap can be used to scan for the evalkit. sudo nmap sP <network identifier/netmask>
Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 12 / 15 Aug. 2020, Revision 01 Document No.: PA10003599 Touch-it CE 15,6 Operating Instructions Example:
sudo nmap sP 10.15.15.0/24 This scans from IP address 10.15.15.0 to 10.15.15.255 4.2 Rebuilding the Image Our source repositories and short instructions on how to rebuild the image can be found on:
https://github.com/software-celo/ces-bsp-platform. 4.3 Recover the Delivery State To recover the delivery state of the image you can follow the instructions found in the CURT User Guide https://christelectronicsystems.box.com/v/curt-manual (PA10002483). Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 13 / 15 Aug. 2020, Revision 01 Document No.: PA10003599 Touch-it CE 15,6 Operating Instructions DISCLAIMER Technical data are subject to modification and delivery subject to availability. Any liability that the data and illustrations are complete, actual or correct is excluded. Designations may be trademarks and/or copyrights of the respective manufacturer, the use of which by third parties for their own purposes may infringe the rights of such owner. Copyright / Christ Electronic Systems GmbH a member of the Christ Company Group 14 / 15 Aug. 2020, Revision 01 Document No.: PA10003599