TR205F DC Wall Control SPECIFICATION and INSTRUCTION SHEET DESCRIPTION: Variable speed DC ceiling fan control with light dimmer switch and canopy receiver. ELECTRICAL SPECS: 120V, 60Hz Ceiling Fan FAN MODELS USED: most DC Fanimation fans - see catalog or visit our website, fanimation.com for more information DPRWATON How to Wire and Operate Your Wall Control ___WHTEAg IN AC120V 60HZ L BLACK BLACK & WHITE BLACK yeti ow, [BLACK ACINL |igreen [TO MOTOR L
|GROUND SLIM 4 WOVTE ANTENNA WI-FI
\LYELLOW GREEN le YELLOW & GREEN GROUND YELLOW YELLOW Figure 1 4 WARNING To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If fan or supply wires are different colors than indicated, have this unit installed by a qualified electrician. IMPORTANT: Using a full range dimmer switch
(not included) to control fan speed will damage the fan. To reduce the risk of fire or electrical shock, do not use a full range dimmer switch to control fan speed. 1. Dip Switch Set Up (Figure 2) NOTE: The remote unit has 32 different code combinations. To prevent possible interference from or to other remote units, simply change the combination code in the remote and receiver. NOTE: Factory setting is all up. Do not use this position.
+ To set the code on receiver unit, slide dip switches to the same positions as set on the remote.
* To set the remote code with a small screwdriver or ball point pen (neither included), slide dip switches firmly up or down to same as receiver unit. LEARN key is for the ceiling fan speed learning key. Press it to learn the speed of new fan blade.
(Only for some fan model #)
+ Restore electrical power. Figure 2 2. Connect wires using connectors as shown in Figure 1. 3. Remote functions: (Figure 3) OFF (MD) on
* Turns control ON/OFF
+ Indicator LED light: fan speed and light dimmer indicator
@button:Tap once to turn off fan. Press and hold this button for 5 seconds to turn buzzer on or off.
+ Fan Speed:
J Turns on fan and turns speed up. V Turns on fan and turns speed down. oR Light button: Turn light ON/OFF. aA Increases light output level. V Decreases light output level.
* Sleep Timer:
The fan and light will turn off after 1 hour. GR) The fan and light will turn off after 3 hours.
) The fan and light will turn off after 6 hours. ft Home Away: Tap this button, the light will blink twice signaling this feature is on; the fan will turn off and the light will randomly turn on and off while you are away. Pressing any button will cancel the feature. Se Fresh Air: Fan speed will modulate to simulate a natural breeze. R Safe Exit: Tap once, the light will blink once;
fan and light will turn off after 1 minute. Pressing any button will cancel this feature.
+ Reverse button:
xh Summer- The fan runs counterclockwise. Airflow will provide a downward cooling breeze
% Winter- The fan runs clockwise. Airflow will force warm air downward without a noticeable breeze. 4 WARNING To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the wall plate and the wall. 4 WARNING Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan unless blades are in place. Noise and fan damage could result.
@ FANIMATION Figure 3 LEARNING PROCESS 4. This unit finished learning process inside manufactory, if replace receiver. user need to redo learning process before using this unit. 2. Install the battery 3V in transmitter. 3. After installing the unit and power on and press learn key 1~3seconds, lights will be flashing twice and turn off, which indicate that learning process finished. Learning effect distance is same with remotes. Please note that must press the * within 30sensonds after power on Please note that the transmitter can learn in multiple receiver, when doing leaming process please make sure not lear in other receiver. Suggest to separate power switches of fans in 2 meter range. OTo assure continued FCC compliance:
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. FCC ID: KUJCE10722 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation 10983 Bennett Parkway Zionsville, IN 46077 FANIMATION SHOWROOM COLLECTION
(888) 567-2055 FAX (866) 482-5215, Outside U.S. call (317) 733-4113 WWW.FANIMATION.COM Copyright 2019 Fanimation 2019/05 V.01 CC del Control de Pared TR205F Hoja de instrucciones y especificaciones Descripcin: Control de ventilador de techo CC con velocidad variable, atenuador de iluminacion y receptor de dosel. Especificaciones elctricas: 120 voltios, 60 Hz., Ventilador. Modelos de ventilador usado: La mayoria CC de ventiladores Fanimation-
Consulte el catalogo o visite nuestra pagina web www.fanimation.com para mas informacion ARMATON Como realizar el cableado y como utilizar el control de Pared Blanco (AC IN N) lact20v 6042. 7 7 JAmarillo, L Negro Negro "Verde [Negro a Motor L
(ACINL) Jpuesta la tierra Negro y Blanco nz ooueig k o160N ANTENA Amarillo/Verde Puesta atierra Amarillo/Verde ae marillo Amarillo Figura 1 4 ADVERTENCIA Para evitar posibles descargas elctricas, asegurese de que la electricidad est desconectada en la caja de fusibles principal antes de realizar la instalacion elctrica. NOTA: Si no esta seguro de si la caja de distribucion elctrica tiene conexi6n a tierra, pida asesoramiento a un electricista autorizado, ya que la conexion a tierra es 00 fundamental para un funcionamiento seguro. Oo Oo Oo IMPORTANTE: El uso de un atenuador de iluminacion aS completo (no incluido) para controlar la velocidad del Sy 2 ventilador dafiara el ventilador. Para reducir el riesgo de incendio o descarga elctrica, no use un atenuador de iluminacin completo para controlar la velocidad del ventilador. 1. Configuracion del interruptor Dip (Figura 2) Interruptores NOTA: El mando a distancia incluido en este ventilador tiene 32 combinaciones diferentes de codigos. Para evitar posibles interferencias desde o hacia otros mandos a distancia, modifique el codigo de combinacion de su transmisor y receptor. NOTA: Los ajustes de fabricas vienen con todos los interruptores hacia arriba. No utilice esta posicion.
* Para configurar el codigo de unidad del receptor. Deslice los interruptores de codigo a las mismas posiciones que en el transmisor. Figura 2
* Para configurar el codigo del mando a distancia, Mueva los interruptores de cddigo hasta colocar el cddigo de seleccion en la posicion arriba o abajo. Con un destornillador pequefio o con una lapicera
(no se incluye) deslice firmemente hacia arriba o hacia abajo. Latecla LEARN es para la tecla de aprendizaje de velocidad del ventilador de techo. Pulsela para aprender la velocidad de una pala nueva de ventilador.
(solo para algunos # modelos de ventilador)
+ Restaure la electricidad. 2. Realice las conexiones de cables al bloque del terminal como se muestra en la Figura 1. 3. Funciones del control remoto: (Figura 3) or GED) on
+ Enciende y apaga el control tH!
+ Luz LED del indicador: Velocidad del ventilador e indicador atenuante de la iluminacin
+ @Boton: Toque este boton apaga el ventilador. Mantenga pulsado el botdn durante 5 segundos para encender o apagalo el zumbador.
+ Velocidad del ventilado:
nciende el ventilador y aumenta la velocidad. A Enciende el ventilador y la velocidad nciende el ventilador y disminuye la velocidad. E de el lad d la velocidad oe Botn de la lampara: Enciende o apaga la luz A Aumenta el nivel de salida de la iluminacin. V_ Disminuye el nivel de salida de la iluminacion.
* Temporizador de apagado automatico:
@) El ventilador se apagara despus de 1 horas.
&) El ventilador se apagara despus de 3 horas. El ventilador se apagara despus de 6 horas.
* fy Lejos de casa: Toque este boton, la luz parpadeara dos veces para indicarle que se habra completado el proceso de configuracion, el ventilador se apagara y la luz se encendera y apagara aleatoriamente mientras est lejos, pulse ningun botdn(es) cancelar la funcin. @aAir Fresco: La velocidad del ventilador se modulara para simular la brisa natural. R Salida segura: Toque este boton, la luz parpadeara dos veces para indicarle que se habra completado el proceso de configuracion, la luz y el ventilador se apagara despus de 1 minuto, pulse ningun botn(es) cancelar la funcin. FANIMATION Figura 3 4 ADVERTENCIA Para evitar un posible incendio o descarga elctrica, asegurese de que los cables elctricos estn completamente dentro de la caja de conexiones y no estn siendo pisados entre la placa de la pared y la propia pared. 4 ADVERTENCIA Verifique que todas las conexiones estn bien ajustadas, incluida la conexi6n a tierra, y que no haya ningun cable desnudo visible en los conectores de cables, a excepcion del cable de conexion a tierra. No haga funcionar el ventilador hasta que las aspas estn colocadas. Podrian producirse ruidos y dafios en el ventilador. @@oton de revesa:
ME Verano- El ventilador funciona en el sentido contrario a las agujas del reloj. El flujo del aire ofrece una brisa refrigerante hacia abajo.
# Invierno- El ventilador funciona en el sentido de las agujas del reloj. El flujo del aire fuerza el aire caliente hacia abajo sin una brisa visible. 10983 Bennett Parkway Zionsville, IN 46077 Llame Sin Cargo al (888) 567-2055 FANIMATION Fae ta sci Desde fuera de los EE.UU. llame al (317) 733-4113, Copyright 2019 Fanimation SHOWROOM COLLECTION Visite nuestro sitio Web en www.fanimation.com 2019/05 V.01