WIRELESS PIR MOTION DETECTOR 433 MHz Installation Instructions RF-PIR-433-D-NN Introduction A motion sensor (passive-infrared or PIR) detects movement within a specific area by sensing the infrared energy emitted from a body as it moves across the sensors field of view. When this motion is detected, the sensor transmits an alarm signal to the control panel. Use a motion sensor to protect locations where door/window sensors are impractical or not needed. For example, use a motion sensor to protect large areas or open floor plans. Motion sensors also provide backup protection for door/window sensors. The sensor features a 3 minute lockout of alarm signals. When an alarm occurs, no additional alarm signals are sent for the next 3 minutes. This is to increase battery life in high traffic areas. The following installation guidelines must be met to provide false alarm immunity. The sensor must be mounted on a wall surface or incline mounted in a corner at a mounting height of 7.5 feet (2.3 m) The sensitivity switch must be set to Low. Room temperature must be kept between 60 and 120 F
(16 and 49 C). Do not aim the sensor at windows, fireplaces, air conditioners, area heaters, forced air heating vents, or place it in direct sunlight. Windows should be closed in any area which has an armed motion sensor. Position the sensor to protect an area where an intruder would be most likely to walk across the detection pattern. Mount the motion sensor on a rigid surface which is free from vibrations. Mount the sensor permanently on a flat wall or in a corner. Do not set it on a shelf. Mount the motion sensor on an insulated, outside wall facing in. Position the sensor so it faces a solid reference point, like a wall. If possible, locate sensors within 100 feet (30.5 m) of the panel. While a transmitter may have a range of 500 feet
(152 m) or more out in the open, the environment at the installation site can have a significant effect on transmitter range. Sometimes a change in sensor location can help overcome adverse wireless conditions. Do not mount the sensor near duct work or other large metallic surfaces which may affect the RF signals (see Final Testing on page 2). Actual acceptable transmitter range should be verified for each installation. Mounting Location A. Wall mounting:
1. Sensor base fastened flat on vertical wall ( 2 degrees). 2. Height = 7.5-9.8 (2.3m or 3m) above floor of monitored area. 3. Clear line-of-sight from sensor to monitored area Note: glass will block sensors view. 4. Sensor aimed away from windows and reflected sunlight. 5. Sensor aimed away from heaters or heater/cooler outlets. 6. Sensor aimed so that likely intruder paths cross three views. I-RF-PIR-433-D-NN Rev 2 Feb 2024 1 30 20 10 0 10 20 30 Top view of lens coverage (measured in feet) 0 40 Battery Installation:
Place (2) CR123 batteries in the battery holder. Be sure that the (+) is in the correct position. Sensitivity setting:
With low sensitivity, detection occurs in 3 to 5 steps. With high sensitivity, detection occurs in 2 to 4 steps. Note: Sensitivity jumper (J1) is only checked on power-up Programming For complete programming information, refer to the specific control panel documentation. To add the sensor to panel memory:
1. Place the panel in program mode. 2. Proceed to the section in programming for enrolling wireless sensors. 3. When the panel prompts enter the senor ID# or trip the sensors tamper, to trip the tamper remove the motions cover. 4. Exit Program Mode. Testing Walk testing:
The sensor enters Walk Test Mode for 60 seconds after power-up. This mode disables the 3 minute lockout of alarm signals. Each alarm resets the 60 second timer. The yellow LED will light solid during Walk Test Mode. 2 Place /Enable jumper for the LED (J3 in its "LED" position). Walk across the monitored area (within the sensor's optical fields-of-view). The LED should turn ON (for Alarm) after about two to four normal steps. Each time the LED turns ON, wait for it to turn OFF. Then, wait 12 seconds before continuing the walk-test. When there is no motion in the monitored area, the LED should remain OFF. Walk testing should be done to determine the sensors actual coverage area. The edge of the coverage pattern is determined by the LED. This may change slightly depending upon the sensitivity setting. Walk test the unit from both directions to determine the pattern boundaries. Caution: Excessive use of the walk test mode LED may reduce battery life. Use only for initial setup and maintenance testing. Replacing the Batteries Battery life depends on how often the detector transmits signals, but is more dependent on the temperature of the installation environment. When the battery voltage gets low, the detector transmits a low battery signal to the panel. The yellow LED will flash once every 10 seconds to denote low battery. The panel then activates trouble beeps to notify the customer that the detector battery must be replaced. Pressing the status button identifies the sensor with the low battery. Replace the battery immediately when this condition occurs, using the following battery: (2) Panasonic CR123A 3V Battery Disposal The batteries used in this sensor are lithium batteries and are not reusable. Be sure to properly dispose of used lithium batteries according to your local hazardous waste disposal laws. Specifications Compatibility:
DSC 433 MHz Wireless Controls Power source:
(2) CR123A 3V Tamper Switch:
Sealed dome-contact Sensitivity Selectable:
High or Low Typical battery life:
4-6 years at 68 F Transmitter frequency:
433 MHz Operating temperature: -40 F to 131 F (-40 - +55 C) Storage temperature range: -30 to 140 F (-34 to 60 C) Maximum humidity:
90% Relative Humidity non-condensing Dimensions:
Housing:
81mm x 60.5mm x 43.2mm (H x W x D) High impact ABS I-RF-PIR-433-D-NN Rev 2 Feb 2024
(USA only) SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER LEGAL RIGHTS THAT VARY FROM STATE TO STATE. MANUFACTURER MAKES NO REPRESENTATION, WARRANTY, COVENANT OR PROMISE THAT ITS ALARM PRODUCTS AND/OR RELATED SOFTWARE (I) WILL NOT BE HACKED, COMPROMISED AND/OR CIRCUMVENTED; (II) WILL PREVENT, OR PROVIDE ADEQUATE WARNING OR PROTECTION FROM, BREAK-INS, BURGLARY, ROBBERY, FIRE; OR (III) WILL WORK PROPERLY IN ALL ENVIRONMENTS AND APPLICATIONS.
All trademarks are the property of their respected owners
. FCC / IC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two cond433ons:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux cond433ons suivantes: (1) cet appareil ne doit pas provoquer d'interfrences et (2) cet appareil doit accepter toute interfrence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil. In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element shall be installed such that a minimum separation distance of 20 cm is maintained from the general population. FCC: 2ABBZ-RF-PIR-433D IC: 11817A-RFPIR433D This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This Class B digital apparatus complies with Canadian ICES-3B. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. MANUFACTURER HEREBY DISCLAIMS ALL WARRANTIES AND REPRESENTATIONS, WHETHER EXPRESS, IMPLIED, STATUTORY OR OTHERWISE INCLUDING (BUT NOT LIMITED TO) ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THESE PRODUCTS AND ANY RELATED SOFTWARE. MANUFACTURER FURTHER DISCLAIMS ANY OTHER IMPLIED WARRANTY UNDER THE UNIFORM COMPUTER INFORMATION TRANSACTIONS ACT OR SIMILAR LAW AS ENACTED BY ANY STATE. I-RF-PIR-433-D-NN Rev 2 Feb 2024