all | frequencies |
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|
manual | photos | labels |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Users Manual | Users Manual | 2.66 MiB | June 28 2021 / June 29 2021 | |||
1 |
|
Internal Photos | Internal Photos | 1.56 MiB | June 28 2021 / June 29 2021 | |||
1 |
|
External Photos | External Photos | 1.20 MiB | June 28 2021 / June 29 2021 | |||
1 | ID Label/Location Info | June 28 2021 / June 29 2021 | ||||||
1 |
|
ID Label/Location Info revised0629 | ID Label/Location Info | 152.36 KiB | June 29 2021 | |||
1 | Block Diagram | Block Diagram | June 28 2021 | confidential | ||||
1 |
|
Confidentiality | Cover Letter(s) | 43.95 KiB | June 28 2021 / June 29 2021 | |||
1 |
|
Declaration of authorization | Cover Letter(s) | 137.96 KiB | June 28 2021 / June 29 2021 | |||
1 | Operational Description | Operational Description | June 28 2021 | confidential | ||||
1 |
|
RF Exposure Info. | RF Exposure Info | 305.39 KiB | June 28 2021 / June 29 2021 | |||
1 | Schematics | Schematics | June 28 2021 | confidential | ||||
1 |
|
Test Report | Test Report | 5.06 MiB | June 28 2021 / June 29 2021 | |||
1 |
|
Test Setup Photos | Test Setup Photos | 507.79 KiB | June 28 2021 / June 29 2021 |
1 | Users Manual | Users Manual | 2.66 MiB | June 28 2021 / June 29 2021 |
1662/1664 Barcode Scanner Setup barcodes included. Version 2.22 Copyright 2011~2019 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided under a license agreement containing restrictions on use and disclosure and is also protected by copyright law. Reverse engineering of the software is prohibited. Due to continued product development this information may change without notice. The information and intellectual property contained herein is confidential between CIPHERLAB and the client and remains the exclusive property of CIPHERLAB CO., LTD. If you find any problems in the documentation, please report them to us in writing. CIPHERLAB does not warrant that this document is error-free. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written permission of CIPHERLAB CO., LTD. For product consultancy and technical support, please contact your local sales representative. Also, you may visit our web site for more information. The CipherLab logo is a registered trademark of CIPHERLAB CO., LTD. All brand, product and service, and trademark names are the property of their registered owners. The editorial use of these names is for identification as well as to the benefit of the owners, with no intention of infringement. CIPHERLAB CO., LTD. Website: http://www.cipherlab.com IMPORTANT NOTICES FOR USA This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION:
Anychangesormodificationsnotexpresslyapprovedbythegranteeofthisdevicecouldvoidtheuser's authoritytooperatetheequipment. RFexposurewarning The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction. FOR CANADA This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled
"Digital Apparatus," ICES-003 of Industry Canada. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de Classe B prescrites dans la norme sur le material brouilleur:
"Appareils Numeriques," NMB-003 edictee par l'Industrie. Canada,IndustryCanada(IC)Notices ThisdevicecomplieswithCanadalicenceexemptRSSstandard(s). Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseinterference,and
(2)thisdevicemustacceptanyinterference,includinginterferencethatmaycauseundesired operationofthedevice. Canada,avisd'IndustryCanada(IC) CetappareilestconformeavecIndustrieCanadaexemptesdelicenceRSSstandard(s). Sonfonctionnementestsoumisauxdeuxconditionssuivantes:(1)cetappareilnedoitpascauser d'interfrenceet(2)cetappareildoitacceptertouteinterfrence,notammentlesinterfrencesqui peuventaffectersonfonctionnement. RadioFrequency(RF)ExposureInformation TheradiatedoutputpoweroftheWirelessDeviceisbelowtheIndustryCanada(IC)radiofrequency exposurelimits.TheWirelessDeviceshouldbeusedinsuchamannersuchthatthepotentialfor humancontactduringnormaloperationisminimized. ThisdevicehasalsobeenevaluatedandshowncompliantwiththeICRFExposurelimitsunder portableexposureconditions.(antennasarelessthan20cmofaperson'sbody). Informationsconcernantl'expositionauxfrquencesradio(RF) Lapuissancedesortiemiseparlappareildesansfilestinfrieurelalimited'expositionaux frquencesradiod'IndustryCanada(IC).Utilisezlappareildesansfildefaonminimiserles contactshumainslorsdufonctionnementnormal. Cepriphriqueagalementtvaluetdmontrconformeauxlimitesd'expositionauxRFd'ICdans desconditionsd'expositiondesappareilsportables.(lesantennessontmoinsde20cmducorpsd'une personne). FOR HAND-HELD PRODUCT WITH RF FUNCTIONS The 1662/1664 unit (FCC ID: Q3N-1662/1664) complies with FCC radiation exposure limits set forth for uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C to OET65. The unit has very low level of RF energy that it is deemed to comply without testing of specific absorption ratio (SAR). The 3610 unit (FCC ID: Q3N-3610) complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & body. It only operated in hand-held used. If only transfer data to the host cordless, please keep the minimum distance 20 cm between machine & body. FOR PRODUCT WITH LASER CAUTION This laser component emits FDA / IEC Class 2 laser light at the exit port. Do not stare into beam. SAFETY PRECAUTIONS RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. The use of any batteries or charging devices, which are not originally sold or manufactured by CipherLab, will void your warranty and may cause damage to human body or the product itself. DO NOT disassemble, incinerate or short circuit the battery. DO NOT expose the scanner or the battery to any flammable sources. For green-environment issue, it's important that batteries should be recycled in a proper way. Under no circumstances, internal components are self-serviceable. CARE & MAINTENANCE Use a clean cloth to wipe dust off the scanning window and the body of the scanner as well as the charging device. DO NOT use/mix any bleach or cleaner. If you want to put away the scanner for a period of time, download the collected data to a host computer when in the memory mode, and then take out the battery. Store the scanner and battery separately. When the scanner resumes its work, make sure the battery is fully charged before use. Keep the scanner away from any magnets and magnetic fields to prevent the laser engine from malfunctioning. If you shall find the scanner malfunctioning, write down the specific scenario and consult your local sales representative. DECLARATION CONFORMITY RELEASE NOTES Version 2.22 Notes Date Oct. 08, 2019 Modified: Symbologies Supported GS1 DataBar Family enabled by default; UPCA Addon 2/Addon 5 appended Modified: Setup QR Code QR Code limited Modified: 1.2.1 Transmit Buffer Continuous Decoding setting Modified: 1.3 LED Indicator Green flashing defined for fully barcodes added charged Modified: 1.3 LED Indicator Red flashing 5 times indicates low battery warning for firmware upgrade Modified: 1.4 Beeper Low battery warning when the scanner gets into download mode for firmware upgrade Modified: 1.4.3 Low Battery Alarm time interval description New: 1.4.4 Bell Ring New: 1.7.8 Multicode Mode (1664 Only) New: 1.7.9 Release Mode Modified: 1.9 Delay between Re-read Laser mode added Modified: 2.1 Bluetooth HID Alt Composing added Modified: 2.1.6/2.4.5/2.6.5 HID Character Transmit Mode By Character as default Modified: 2.1.7 Special Keyboard Feature Bypass with Control Character Output for Windows added New section title for 2.1.9 HID Keyboard Layout (Apple & Non-
Apple System) Modified: 2.1.10 Transmit Speed Fast by default Modified: 2.1.11 BT HID Slave/Master Switching Master by default Code example Modified: 2.3.1 Activate Bluetooth SPP Master Mode - QR Modified: 2.6.7 USB Polling Interval 4ms by default Modified: 3.1.1 Connect to 3610 QR Code example Modified: 3.2.4 Secure Simple Pairing enabled by default Modified: 4.13.2 GS1 DataBar Omnidirectional (RSS-14) enabled by default, Transmit Code ID disabled by default Modified: 4.13.3 GS1 DataBar Expanded (RSS Expanded) -
enabled by default, Transmit Code ID disabled by default Modified: 4.13.4 GS1 DataBar Limited (RSS Limited) - enabled by default, Transmit Code ID disabled by default Modified: change section article to 5.2.1 Single Character Substitution (previous article: Select a Set for Character Substitution) New: 5.2.2 Multiple Characters Substitution Modified: Appendix I - Firmware Upgrade Low battery warning when the scanner gets into download mode 2.21 Jul. 26, 2017 Modified: 1.11 change Addon Security Level for UPC/EAN default to 10 2.20 Jun. 24, 2016 Modified: 1.3 LED indicator descriptions appended (flashing red for Modified: 2.1.1 Activate BT HID & Select Keyboard Type (87) Brazilian Portuguese added for PC & Apple New: 2.4.7 USB HID via 3610 Auto-Rconnection New: 2.5.5 USB VCOM via 3610 Auto-Rconnection Modified: 2.6.1 Activate USB HID & Select Keyboard Type
(87) Brazilian Portuguese added for PC & Apple Modified: Chapter 4 setting barcodes for disabling/enabling all symbologies added New: Appendix VI Keyboard Type One-Scan Barcode indicating battery capacity running low and low battery voltage) Modified: 2.1.1 80 PCAT (Dutch) keyboard type added Modified:
2.1.1 65,66,67,68,69,72,73,75,76,78,79,80~86 keyboard types support Apple keyboard Modified: 2.1.6 note for turning off iOS Auto-Correction added Modified: 2.1.8 setting barcodes for toggling Apple keyboard over BT HID connection added Modified: 2.3.1 a single 1D barcode for connecting to a target device 2.19 Sep. 07, 2015 Modified: descriptions relating to CD-ROM removed Modified: 2.6.1 80 PCAT (Dutch) keyboard type added New: 2.3.5 BT SPP Master Hardware Flow Control New: 2.3.6 BT SPP Master Auto-Rconnection New: 4.16.1 EAN-13 Addon Modes 2.18 Nov. 05, 2014 New: 1.2.4 Record Count of Memory added Modified: 1.11 range of Security Level (2~30 times) Modified: Appendix II #@RDBATCAP serial command added 2.17 May 09, 2014 New: 1.20 Serial Number Stamp New: 1.20.1 Separator between Serial Number and Data New: 2.1.10 BT HID Slave/Master Switching New: 2.1.11 BT HID Auto-Reconnection New: 2.5.2 Activate USB Virtual COM_CDC New: 2.6.7 USB Polling Interval Modified: 3.2.2 length of device name changed to 13 bytes (max.) New: 4.11.3 GS1 Formatting, Application ID Mark Modified: 4.13.2 add GS1 formatting (Omnidirectional) barcodes Modified: 4.13.3 add GS1 formatting (Expanded) barcodes Modified: 4.13.4 add GS1 formatting (Limited) barcodes New: 4.13.6 Field Separator New: 4.13.7 Application ID Mark New: 4.21.1 add GS1 formatting (Composite CC-A/B) barcodes New: 4.21.2 add GS1 formatting (Composite CC-C) barcodes New: 4.21.6 Field Separator New: 4.21.7 Application ID Mark Modified: Appendix I Notes for upgrading 3610 CPU/Bridge firmware added 2.16 Mar. 06, 2014 Modified: Care & Maintenance Keep the scanner away from any magnets and magnetic fields to prevent the laser engine from malfunctioning. added Modified: 1.1.2 - Enable/Disable the [Delete] key barcodes added Modified: 1.17.3 Illumination Brightness setup barcode added Modified: 3.2.2 Changing Device Name barcode added Modified: Appendix II #$ShowScanner, #$SelectScannerN,
#@BEEP,xx, #@RLED,xx, #@GLED,xx, #@VIBR,xx added Modified: Appendix III remove Send from CR*/Send/ENTER*
2.15 2.14 Jul. 19, 2013 Added: 1.18.3 Disable Hardware Reset (setting barcodes) Jun. 10, 2013 Added: 1.19 Mobile Phone/Display Mode Added: 2.1.9 Transmit Speed Added: 3.2.4 Secure Simple Pairing (2.1.9 Simple Pairing for iPhone/iPad removed) Added: 4.15.1 EAN-8 Check Digit function barcode added Added: 4.16.3 EAN-13 Check Digit function barcode added 2.13 Mar. 20, 2013 Add: 2.3.1 Activate Bluetooth SPP Master Mode 2D barcode for connecting to a target device Add: 3.1.1 Connect to 3610 2D barcode for connecting to 3610 2.12 Dec. 24, 2012 New: Quick Start Create 2D One-Scan Barcode Modified: 1.12 Negative Barcodes (1664 Only) Modified: 1.13.2 Disable Direct USB Interface barcode number Modified: 4.16.1 Convert to ISBN (support for 979 prefix removed) Modified: 4.16.2 Convert to ISSN (1664 Only) Modified: 2.5.1/2.7/3.1 Required USB Virtual COM Driver version 5.4 New: 2.7.2 Activate USB Virtual COM_CDC barcode (100010) added Modified: Appendix I Firmware Upgrade Direct USB Virtual COM_CDC barcode (100010) added July 04, 2012 Add: 5.8 AIM Code ID Jun. 18, 2012 Add: List the Current Settings: Simple Pairing Status, Code Type Add: 4.18.1 UPC-A Convert to EAN-13 Add: 1.1.1 Power Level and 1.2.3 Free Memory Add: 2.1.1/2.4.1/2.6.1 HID for PCAT (Swiss German) and PCAT (Danish) Add: 2.1.7/2.4.6/2.6.6 Special Keyboard Feature Add: 2.1.9 Simple Pairing for iPhone/iPad Add: Appendix V Family Name/First Name/ Middle Name Truncation and check the file type of ANSI Apr. 10, 2012 Modified: 1.10 remove Reading Redundancy Three times Mar. 20, 2012 Add: 1662 model and Set Up Drivers License Feb. 06, 2012 Add: Chapter 6 Fields of Time Stamp Jan. 11, 2012 Modified: Specifications: Dimension and Weight description Dec. 28, 2011 Add: 1.1.2 add delay note for activating the scanner from power off 1.00 Nov. 30, 2011 Initial release mode 2.11 2.10 2.01 2.00 1.03 1.02 1.01 CONTENTS IMPORTANT NOTICES ........................................................................................................- 3 -
For USA........................................................................................................................................ - 3 -
For Canada ................................................................................................................................. - 3 -
For Hand-held Product with RF Functions...................................................................... - 4 -
For Product with Laser........................................................................................................... - 4 -
Safety Precautions .................................................................................................................. - 4 -
Care & Maintenance................................................................................................................ - 4 -
Declaration Conformity ......................................................................................................... - 5 -
RELEASE NOTES ....................................................................................................................- 7 -
INTRODUCTION ....................................................................................... 1 Get Familiarized with 1662/1664 and 3610 ............................................... 2 Install the Battery into 1662/1664 ........................................................ 2 Charge the Battery ............................................................................. 3 Charge the Battery via Charger ............................................................ 4 Use 3610 .......................................................................................... 5 Inside the Package ................................................................................ 6 Product Highlights ................................................................................. 6 Symbologies Supported .......................................................................... 7 QUICK START .......................................................................................... 9 Enter Configuration Mode ...................................................................... 11 Exit Configuration Mode ........................................................................ 11 Default Settings ................................................................................... 12 Save User Settings as Defaults ........................................................... 12 Restore User Defaults ........................................................................ 12 Restore System Defaults .................................................................... 12 Read a Setup Barcode ........................................................................... 13 Configure Parameters ........................................................................ 13 List the Current Settings .................................................................... 17 Create One-Scan Setup Barcodes............................................................ 19 1D One-Scan Setup Barcode ............................................................... 19 Setup QR Code ................................................................................. 20 UNDERSTANDING THE BARCODE SCANNER ............................................ 21 1.1 Battery .......................................................................................... 21 1.1.1 Power Level ............................................................................. 22 1.1.2 How to Operate the Scanner ....................................................... 22 1.1.3 Auto Power Off & Power-Saving .................................................. 23 1.2 Memory ......................................................................................... 26 1662/1664 Barcode Scanner User Guide 1.2.1 Transmit Buffer ........................................................................ 26 1.2.2 Memory Mode .......................................................................... 27 1.2.3 Free Memory ............................................................................ 29 1.2.4 Record Count of Memory ............................................................ 29 1.3 LED Indicator ................................................................................. 30 1.3.1 Good Read LED ........................................................................ 31 1.3.2 Good Read LED Duration ............................................................ 31 1.4 Beeper .......................................................................................... 32 1.4.1 Beeper Volume ......................................................................... 33 1.4.2 Good Read Beep ....................................................................... 34 1.4.3 Low Battery Alarm .................................................................... 35 1.4.4 Bell Ring .................................................................................. 35 1.5 Vibrator ......................................................................................... 36 1.5.1 Good Read Vibrator ................................................................... 36 1.5.2 Good Read Vibrator Duration ...................................................... 36 1.6 Send NR to Host ........................................................................... 37 1.7 Scan Modes .................................................................................... 38 1.7.1 Laser Mode .............................................................................. 39 1.7.2 Auto Off Mode .......................................................................... 39 1.7.3 Auto Power Off Mode ................................................................. 39 1.7.4 Aiming Mode (1664 Only) .......................................................... 40 1.7.5 Multi-Barcode Mode .................................................................. 40 1.7.6 Continuous Mode (1662 Only) .................................................... 41 1.7.7 Alternate Mode (1662 Only) ....................................................... 41 1.7.8 Multicode Mode (1664 Only) ....................................................... 42 1.7.9 Release Mode ........................................................................... 43 1.8 Scanning Timeout ........................................................................... 44 1.9 Delay between Re-read .................................................................... 45 1.10 Read Redundancy for All Symblogies ................................................ 46 1.11 Addon Security for UPC/EAN Barcodes .............................................. 47 1.12 Negative Barcodes (1664 Only) ....................................................... 47 1.13 Use Direct USB Cable ..................................................................... 48 1.13.1 Direct USB Interface ................................................................ 48 1.13.2 Disable Direct USB Interface ..................................................... 48 1.14 Picklist Mode (1664 Only) ............................................................... 49 1.15 Pager Beep Duration ...................................................................... 49 1.16 Time Stamp .................................................................................. 50 1.16.1 Date and Time Settings ............................................................ 50 1.16.2 Separator for Date and Time ..................................................... 52 1.16.3 Date Format ........................................................................... 53 1.17 2D Decode Setting (1664 Only) ....................................................... 54 1.17.1 Aiming Pattern ........................................................................ 54 1.17.2 Decoding Illumination .............................................................. 54 1.17.3 Illumination Brightness ............................................................ 54 1.18 Hardware Reset ............................................................................ 55 1662/1664 Barcode Scanner User Guide 1.18.1 Restore System Defaults .......................................................... 55 1.18.2 Reset Connection .................................................................... 55 1.18.3 Disable Hardware Reset ........................................................... 55 1.19 Mobile Phone/Display Mode ............................................................. 56 1.20 Serial Number Stamp ..................................................................... 56 1.20.1 Separator between Serial Number Stamp and Data ...................... 56 SELECTING OUTPUT INTERFACE ............................................................. 57 2.1 Bluetooth HID ............................................................................... 58 2.1.1 Activate Bluetooth HID & Select Keyboard Type ........................... 59 2.1.2 Reset Connection ...................................................................... 60 2.1.3 Keyboard Settings .................................................................... 61 2.1.4 Inter-Character Delay ................................................................ 67 2.1.5 Inter-Function Delay ................................................................. 68 2.1.6 HID Character Transmit Mode ..................................................... 69 2.1.7 Special Keyboard Feature ........................................................... 69 2.1.8 Keypad Support for iPhone/iPad .................................................. 70 2.1.9 HID Keyboard Layout (Apple & Non-Apple System) ........................ 70 2.1.10 Transmit Speed ...................................................................... 71 2.1.11 BT HID Slave/Master Switching ................................................. 71 2.1.12 BT HID Auto-Reconnection ....................................................... 71 2.2 Bluetooth SPP Slave ....................................................................... 72 2.2.1 Activate Bluetooth SPP Slave Mode ............................................ 72 2.2.2 Inter-Function Delay ................................................................. 72 2.2.3 ACK/NAK Timeout ..................................................................... 73 2.3 Bluetooth SPP Master ..................................................................... 74 2.3.1 Activate Bluetooth SPP Master Mode ........................................... 74 2.3.2 Inter-Function Delay ................................................................. 76 2.3.3 ACK/NAK Timeout ..................................................................... 77 2.3.4 Switch between Master/Slave Mode ............................................. 77 2.3.5 BT SPP Master Hardware Flow Control .......................................... 78 2.3.6 BT SPP Master Auto-Reconnection ............................................... 78 2.4 USB HID via 3610 ........................................................................... 79 2.4.1 Activate USB HID & Select Keyboard Type .................................... 80 2.4.2 Keyboard Settings .................................................................... 81 2.4.3 Inter-Character Delay ................................................................ 87 2.4.4 Inter-Function Delay ................................................................. 87 2.4.5 HID Character Transmit Mode ..................................................... 88 2.4.6 Special Keyboard Feature ........................................................... 88 2.4.7 USB HID via 3610 Auto-Reconnection .......................................... 88 2.5 USB Virtual COM via 3610 ................................................................ 89 2.5.1 Activate USB Virtual COM ........................................................... 89 2.5.2 Activate USB Virtual COM_CDC ................................................... 89 2.5.3 Inter-Function Delay ................................................................. 89 2.5.4 ACK/NAK Timeout ..................................................................... 90 2.5.5 USB VCOM via 3610 Auto-Reconnection ....................................... 91 2.6 Direct USB HID ............................................................................... 92 1662/1664 Barcode Scanner User Guide 2.6.1 Activate USB HID & Select Keyboard Type .................................... 93 2.6.2 Keyboard Settings .................................................................... 95 2.6.3 Inter-Character Delay .............................................................. 101 2.6.4 Inter-Function Delay ............................................................... 101 2.6.5 HID Character Transmit Mode ................................................... 102 2.6.6 Special Keyboard Feature ......................................................... 102 2.6.7 USB Polling Interval ................................................................ 102 2.7 Direct USB Virtual COM .................................................................. 103 2.7.1 Activate USB Virtual COM ......................................................... 103 2.7.2 Activate USB Virtual COM_CDC ................................................. 103 2.7.3 Inter-Function Delay ............................................................... 103 2.7.3 ACK/NAK Timeout ................................................................... 104 SET UP A WPAN CONNECTION .............................................................. 106 3.1 Connecting via 3610 ...................................................................... 107 3.1.1 Connect to 3610 ..................................................................... 107 3.1.2 Change Interface .................................................................... 109 3.1.3 Configure Related Settings ....................................................... 110 3.2 Connecting via Bluetooth Dongle .................................................... 110 3.2.1 Change Interface .................................................................... 110 3.2.2 Configure Related Settings ....................................................... 111 3.2.3 Connect to Dongle .................................................................. 115 3.2.4 Secure Simple Pairing (SSP) ..................................................... 122 CHANGE SYMBOLOGY SETTINGS .......................................................... 123 4.1 Codabar ....................................................................................... 124 4.1.1 Start/Stop Transmission .......................................................... 124 4.1.2 CLSI Conversion ..................................................................... 124 4.1.3 Code Length Qualification ........................................................ 125 4.2 Code 25 Industrial 25 ................................................................. 126 4.2.1 Code Length Qualification ........................................................ 127 4.3 Code 25 Interleaved 25 ............................................................... 128 4.3.1 Verify Check Digit ................................................................... 128 4.3.2 Transmit Check Digit ............................................................... 128 4.3.3 Convert to EAN-13 .................................................................. 129 4.3.4 Code Length Qualification ........................................................ 130 4.4 Code 25 Matrix 25 ...................................................................... 131 4.4.1 Verify Check Digit ................................................................... 131 4.4.2 Transmit Check Digit ............................................................... 131 4.4.3 Code Length Qualification ........................................................ 132 4.5 Code 25 Chinese 25 .................................................................... 133 4.6 Italian Pharmacode (Code 32) ......................................................... 134 4.7 Code 39 ....................................................................................... 135 4.7.1 Verify Check Digit ................................................................... 135 4.7.2 Transmit Check Digit ............................................................... 135 4.7.3 Standard/Full ASCII Code 39 .................................................... 136 4.7.4 Code Length Qualification ........................................................ 137 1662/1664 Barcode Scanner User Guide 4.8 Trioptic Code 39 ........................................................................... 138 4.9 Code 93 ....................................................................................... 139 4.9.1 Code Length Qualification ........................................................ 140 4.10 Code 128 ................................................................................... 141 4.11 GS1-128 (EAN-128) .................................................................... 142 4.11.1 Transmit Code ID .................................................................. 142 4.11.2 Field Separator (GS Character) ............................................... 142 4.11.3 GS1 Formatting .................................................................... 143 4.12 ISBT 128 ................................................................................... 144 4.12.1 ISBT Concatenation (1664 Only) ............................................. 144 4.12.2 ISBT Concatenation Redundancy (1664 Only) ........................... 145 4.13 GS1 DataBar (RSS Family) ........................................................... 146 4.13.1 Select Code ID ...................................................................... 146 4.13.2 GS1 DataBar Omnidirectional (RSS-14) .................................... 147 4.13.3 GS1 DataBar Expanded (RSS Expanded) .................................. 148 4.13.4 GS1 DataBar Limited (RSS Limited) ......................................... 149 4.13.5 Convert to UPC/EAN .............................................................. 150 4.13.6 Field Separator (GS Character) ............................................... 150 4.13.7 Application ID Mark ............................................................... 151 4.14 MSI ........................................................................................... 152 4.14.1 Verify Check Digit ................................................................. 152 4.14.2 Transmit Check Digit ............................................................. 152 4.14.3 Code Length Qualification ....................................................... 153 4.15 EAN-8 ........................................................................................ 154 4.15.1 Transmit Check Digit ............................................................. 154 4.16 EAN-13 ...................................................................................... 155 4.16.1 EAN-13 Addon Modes ............................................................ 156 4.16.2 Convert to ISBN .................................................................... 159 4.16.3 Convert to ISSN (1664 Only) .................................................. 159 4.16.4 Transmit Check Digit ............................................................. 159 4.17 UCC Coupon Extended Code ......................................................... 160 4.18 UPC-A........................................................................................ 161 4.18.1 Convert to Ean-13 ................................................................. 162 4.18.2 Transmit System Number ....................................................... 162 4.18.3 Transmit Check Digit ............................................................. 162 4.19 UPC-E ........................................................................................ 163 4.19.1 Select System Number .......................................................... 164 4.19.2 Convert to UPC-A .................................................................. 164 4.19.3 Transmit System Number ....................................................... 165 4.19.4 Transmit Check Digit ............................................................. 165 4.20 Code 11 ..................................................................................... 166 4.20.1 Verify Check Digit ................................................................. 166 4.20.2 Transmit Check Digit ............................................................. 166 4.20.3 Code Length Qualification ....................................................... 167 4.21 Composite Code .......................................................................... 168 1662/1664 Barcode Scanner User Guide 4.21.1 Composite CC-A/B ................................................................ 168 4.21.2 Composite CC-C .................................................................... 168 4.21.3 Composite TLC-39 ................................................................. 169 4.21.4 UPC Composite Mode ............................................................. 169 4.21.5 GS1-128 Emulation Mode for UCC/EAN Composite Codes ............ 170 4.21.6 Field Separator (GS Character) ............................................... 170 4.21.7 Application ID Mark ............................................................... 171 4.22 US Postal Code ........................................................................... 172 4.22.1 US Postnet ........................................................................... 172 4.22.2 US Planet ............................................................................. 172 4.22.3 Transmit Check Digit ............................................................. 172 4.23 UK Postal Code ........................................................................... 173 4.23.1 UK Postal ............................................................................. 173 4.23.2 Transmit Check Digit ............................................................. 173 4.24 More Postal Code ........................................................................ 174 4.24.1 Japan Postal ......................................................................... 174 4.24.2 Australian Postal ................................................................... 174 4.24.3 Dutch Postal ......................................................................... 174 4.24.4 USPS 4CB/One Code/Intelligent Mail ........................................ 174 4.24.5 UPU FICS Postal .................................................................... 175 4.25 2D Symbologies .......................................................................... 176 4.25.1 PDF417 ............................................................................... 176 4.25.2 MicroPDF417 ........................................................................ 176 4.25.3 Data Matrix .......................................................................... 177 4.25.4 Maxicode ............................................................................. 178 4.25.5 QR Code .............................................................................. 178 4.25.6 MicroQR ............................................................................... 178 4.25.7 Aztec................................................................................... 178 4.26 Macro PDF .................................................................................. 179 4.26.1 Transmit/Decode Mode .......................................................... 179 4.26.2 Escape Characters ................................................................. 180 4.26.3 Transmit Control Header ........................................................ 180 DEFINING OUTPUT FORMAT ................................................................. 181 5.1 Letter Case .................................................................................. 181 5.2 Character Substitution ................................................................... 182 5.2.1 Single Character Substituion .................................................... 183 5.2.2 Multiple Character Substitution ................................................. 184 5.2.3 Symbologies for Character Substitution (All 3 Sets) ..................... 186 5.3 Prefix/Suffix Code ......................................................................... 196 5.4 Code ID ....................................................................................... 197 5.4.1 Select Pre-defined Code ID ....................................................... 197 5.4.2 Change Code ID ..................................................................... 200 5.4.3 Clear Code ID Settings ............................................................ 203 5.5 Length Code ................................................................................. 204 5.6 Multi-Barcode Editor ...................................................................... 212 5.6.1 Edit a Concatenation of Barcodes .............................................. 213 1662/1664 Barcode Scanner User Guide 5.6.2 Activate the Concatenation of Barcodes ...................................... 215 5.7 Removal of Special Character.......................................................... 216 5.8 AIM Code ID ................................................................................. 216 APPLYING FORMATS FOR DATA EDITING ............................................. 217 6.1 Activating Editing Formats .............................................................. 218 6.1.1 Activate Editing Formats .......................................................... 218 6.1.2 Exclusive Data Editing ............................................................. 219 6.2 How to Configure Editing Formats .................................................... 220 6.2.1 Select Format to Configure ....................................................... 221 6.2.2 Restore Default Format ............................................................ 222 6.3 Configure Format Define Data Criteria .......................................... 223 6.3.1 Applicable Code Type .............................................................. 223 6.3.2 Data Length ........................................................................... 233 6.3.3 Matching String & Location ....................................................... 234 6.4 Configure Format Define Data Field .............................................. 235 6.4.1 Start Position ......................................................................... 235 6.4.2 Field Adjustment .................................................................... 235 6.4.3 Total Number of Fields ............................................................. 236 6.4.4 Field Settings ......................................................................... 237 6.4.5 Pause Field Setting ................................................................. 243 6.5 Configure Format Define Transmission Sequence ........................... 244 6.6 Programming Examples ................................................................. 246 6.6.1 Example I .............................................................................. 246 6.6.2 Example II ............................................................................. 247 SPECIFICATIONS .................................................................................. 249 FIRMWARE UPGRADE ........................................................................... 251 How to Upgrade 1662/1664 Firmware ................................................... 251 Using 3610 .................................................................................... 251 Use Direct USB Virtual COM .............................................................. 253 Use Bluetooth Dongle ..................................................................... 254 How to Upgrade 3610 Firmware ............................................................ 256 Upgrade 3610 CPU Firmware ............................................................ 256 Upgrade 3610 USB Bridge Firmware .................................................. 257 HOST SERIAL COMMANDS .................................................................... 259 Serial Commands ............................................................................... 259 Example ........................................................................................ 261 3610 Setup Barcodes & Serial Commands .............................................. 263 3610 Serial Commands and Equivalent Setup Barcodes ........................ 264 Example ........................................................................................ 266 KEYBOARD WEDGE TABLE .................................................................... 267 Key Type & Status .............................................................................. 268 Key Type ....................................................................................... 268 1662/1664 Barcode Scanner User Guide Key Status ..................................................................................... 268 Example ............................................................................................ 269 NUMERAL SYSTEMS .............................................................................. 271 Decimal System ................................................................................. 271 Hexadecimal System ........................................................................... 272 ASCII Table ....................................................................................... 273 Entering PIN Code for Authentication ..................................................... 274 Use Preset PIN ............................................................................... 274 Disable Authentication or Use Random PIN ......................................... 275 SET UP DRIVER LICENSE (1664 ONLY) ................................................. 277 License Parsing .................................................................................. 277 File Type ........................................................................................ 277 License Data ...................................................................................... 278 Separators and Fields .......................................................................... 284 Edit Separators ............................................................................... 285 Edit Fields ...................................................................................... 286 KEYBOARD TYPE ONE-SCAN BARCODE ................................................. 287 Remote USB HID (via 3610) ................................................................ 287 Bluetooth HID .................................................................................... 289 INTRODUCTION CipherLabs small-form-factor 1600 Series Barcode Scanners are specifically designed to answer the mobile demands. The palm-sized scanners are designed to help accelerate productivity while lowering the total cost of ownership. Intensive data collection jobs are made easier with fast, accurate barcode scanning in various working environments, especially in small businesses. Integrating short-distance cordless technology to small-
form-factor scanners, the scanners are ideal for carrying as in pocket, and thus give workers tether-free mobility anytime anywhere and get job done more efficiently. This line of scanners deliver data over a cordless personal network at a range of up to 10 meters and a prolonged battery life to keep business running. 1662/1664 is a new ordering option provided for adapting a advanced scan engine to read both 1D and 2D barcodes. Owing to the compact design, extremely low power consumption, and powerful decoding capability, the 1600 Series Barcode Scanners are the best choice for the following applications Receiving in Retail Product labeling & Tracking Shelf Product Replenishment Mobile Point of Sale (POS) Mobile Inventory Management Order Picking & Staging Work-In-Process Tracking Material Flow Control Transportation & Distribution Warehousing Asset Management This manual contains information on operating the scanner and using its features. We recommend you to keep one copy of the manual at hand for quick reference or maintenance purposes. To avoid any improper disposal or operation, please read the manual thoroughly before use. Thank you for choosing CipherLab products!
1 Update 1662/1664 Barcode Scanner User Guide GET FAMILIARIZED WITH 1662/1664 AND 3610 INSTALL THE BATTERY INTO 1662/1664 battery cover. 2) Remove the battery cover. 3) Push battery lock to unlocked position. 1) Hold the scanner face down in one hand, press the battery cover, and slide the 4) Insert the battery into the battery compartment. Install the supplied 3.7V/850mAh Li-ion battery into the battery compartment. 5) Push battery lock to lock the battery firmly. 6) Replace the battery cover. 7) Hold down the [Power/Delete] key for about 2 seconds to turn on the scanner. The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off. 2 Enter Setup Note: (1) To turn off the scanner, press the [Power/Delete] key for 2 seconds. The scanner will respond with two short beeps (high tone) and the LED will become solid red. Release the key. Otherwise, let the scanner turn off automatically in specific circumstances. Refer to settings of Auto Power Off.
(2) For shipping and storage purposes, remove the battery from the scanner. This will keep the batteries in good condition for future use. CHARGE THE BATTERY The battery may not be fully charged for shipment. For initial use, it is recommended to fully charge the battery before using the scanner. You can use the Direct USB cable to connect the scanner to PC for charging. It takes approximately 4 hours to fully charge the battery. Refer to 1.13 Use Direct USB Cable. Note: Battery charging stops when the temperature drops below 0C or exceeds 40C. It is recommended to charge the battery at room temperature (18C to 25C) for optimal performance. 1) Install the battery to 1662/1664. 2) Connect 1662/1664 to host computer or notebook via the USB cable. 3) The scanner LED will flash red during charging. When the charging is complete, the LED will turn off. When charging errors occur, the LED will turn solid red. Introduction 3 Update 1662/1664 Barcode Scanner User Guide CHARGE THE BATTERY VIA CHARGER The battery charger is provided for charging the battery outside of the scanner. You may purchase the charger separately. It takes approximately 3 hours to charge the battery to full. Note: Battery charging stops when the temperature drops below 0C or exceeds 40C. It is recommended to charge the battery at room temperature (18C to 25C) for optimal performance. 1) Insert the battery. 2) Connect the power supply cord to the charger. 3) Connect the other end of the power cord to a suitable power outlet. Charger power ON (LED on for 0.5 second) Status LED Meaning
Red, solid Red, solid
Charging battery Green, solid Charging done
Power or battery not ready 4 Enter Setup USE 3610 The CipherLab Dongle (3610) is specifically designed for the scanner to communicate with a host computer cordless. The connection between the scanners and 3610 is made easy and reliable. Refer to 3.1.1 Connect to 3610. Introduction There is one LED indicator provided for communications status. Communication LED Meaning Initialize Blue, solid
Failed to establish a USB connection
Red, solid Red, solid
Red, solid Red, flashing Blue, flashing Blue, flashing Blue, flashing Blue, flashing Serial command mode with USB Virtual COM: wait 3 seconds for starting a serial command Red, flashing Blue, flashing Serial command mode with USB HID: wait 3 seconds for pressing [Num Lock] or [Caps Lock] 5 times via keyboard Wait for connection request from the scanner (Slow flash at 0.5 Hz) Connected with the scanner (Fast flash at 1 Hz) Failed to send data to host via USB Virtual COM (Fast flash at 1 Hz)
Enter Download Mode 5 Update The items included in the package may be different, depending on your order. Save the box and packaging material for future use in case you need to store or ship the scanner. 1662/1664 Barcode Scanner User Guide INSIDE THE PACKAGE 1662/1664 Scanner CipherLab Dongle (3610) Optional Rechargeable Li-ion Battery Pack Direct USB Cable Wristband Setup Cards Quick Start Guide PRODUCT HIGHLIGHTS Small-form-factor and built tough to survive drop test. Extremely low power consumption. Firmware upgradeable. Support most popular barcode 1D/2D symbologies, including GS1-128 (EAN-128), GS1 DataBar (RSS), etc (2D is for 1664 only). Support negative barcodes. Support US driver license decode (1664 only). Support a variety of 2D symbologies, Time Stamp and Paging function. Support different scan modes, including Aiming Mode (1664 only), Alternate Mode
(1662 only) and Multi-Barcode Mode Note. Programmable feedback via LED indicator, beeper and vibrator. Beeping tone and duration programmable for Good Read. 4MB flash memory for Memory Mode operation, storing over 240,000 scans based on EAN-13 barcodes. Provides up to 10 KB SRAM for reserve buffer while getting out of range over a wireless personal area network (WPAN), storing up to 640 scans based on EAN-13 barcodes. Capable of transmitting scanned data, emulating a serial cable (Bluetooth SPP) or as keyboard input (Bluetooth HID), to a notebook computer or PDA with Bluetooth wireless technology. Programmable parameters include data output format, editing format, symbologies. Easy configuration through ScanMaster. Easy connection through CipherConnect, available via online marketplace for mobile devices running on Android 2.x, BlackBerry 5.x, or Windows Mobile 6.x. 6 Enter Setup SYMBOLOGIES SUPPORTED Most of the popular barcode symbologies are supported, as listed below. Each can be individually enabled or disabled. The scanner will automatically discriminate and recognize all the symbologies that are enabled. Refer to Chapter 4 Change Symbology Settings for details of each symbology. Symbologies Supported: Enable/Disable 1D Laser (1662) 2D (1664) Introduction Codabar Code 11 Code 93 MSI Code 128 Code 128 Code 2 of 5 Industrial 25 (Discrete 25) GS1-128 (EAN-128) ISBT 128 Interleaved 25 Matrix 25 Chinese 25 Code 3 of 9 Code 39 Italian Pharmacode (Code 32) Trioptic Code 39 EAN/UPC EAN-8 EAN-8 Addon 2 EAN-8 Addon 5 EAN-13 EAN-13 & UPC-A Addon 2 EAN-13 & UPC-A Addon 5 Bookland EAN (ISBN) UPC-E0 UPC-E1 UPC-E Addon 2 UPC-E Addon 5 UPC-A UPC-A Addon 2 UPC-A Addon 5 Enabled Disabled Enabled Disabled Enabled Enabled Enabled Enabled Enabled Disabled Enabled Disabled Disabled Enabled Disabled Disabled Enabled Disabled Disabled Disabled Enabled Disabled Disabled Disabled Enabled Disabled Disabled Enabled Disabled Enabled Disabled Enabled Enabled Enabled Enabled Enabled Disabled Disabled Enabled Disabled Disabled Enabled Disabled Disabled Enabled Disabled Disabled Disabled Enabled Disabled Disabled Disabled Enabled Disabled Disabled Enabled GS1 DataBar GS1 DataBar Omnidirectional (RSS-14) Enabled 7 Update 1662/1664 Barcode Scanner User Guide
(RSS) GS1 DataBar Truncated Enabled GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional GS1 DataBar Limited (RSS Limited) Enabled GS1 DataBar Expanded (RSS Expanded) Enabled GS1 DataBar Expanded Stacked Composite Code Composite CC-A/B Composite CC-C Composite TLC-39 Postal Code US Postnet USPS 4CB/One Code/Intelligent Mail 2D Symbologies PDF417 US Planet UK Postal Japan Postal Australian Postal Dutch Postal UPU FICS Postal MicroPDF417 Data Matrix Maxicode QR Code MicroQR Aztec Enabled Enabled Enabled Enabled Enabled Enabled Disabled Disabled Disabled Enabled Enabled Enabled Enabled Enabled Enabled Disabled Disabled Enabled Disabled Enabled Enabled Enabled Enabled Enabled 8 Enter Setup QUICK START The configuration of the scanner can be done by reading the setup barcodes contained in this manual or via the ScanMaster software. This section describes the procedure of configuring the scanner by reading the setup barcodes and provides some examples for demonstration. Configuration Mode 1) Hold down the [Power/Delete] key for 2 seconds to turn on the scanner. It will respond with a long beep and its LED will come on-off. 2) Read the Enter Setup barcode. It will respond with six beeps and its LED indicator will become flashing red after reading the barcode. 3) Read more setup barcodes Most of the setup barcodes are normal, and the scanner will respond with two beeps (low-high tone). For special setup barcodes, it requires reading more than one setup barcode to complete the setting. 4) Read the Update or Abort barcode. It will respond with six beeps and its LED indicator will become flashing red after reading the barcode. 5) The scanner will restart automatically upon reading the Update or Abort barcode. It will respond with a long beep and its LED will come on-off. Note: Refer to Appendix II Host Serial Commands for how to configure the 3610 dongle by having the scanner read 3610-related setup barcodes or using serial commands. 9 Update 1662/1664 Barcode Scanner User Guide Working Mode Upon powering up, the scanner will try to establish a connection with 3610 or a computer with Bluetooth wireless technology. Refer to Chapter 3 - Set up a WPAN Connection for details. The connection between the scanners and 3610 is made easy and reliable. Now, it also supports Bluetooth SPP Master Mode as an alternative. Refer to 2.3 Bluetooth SPP Master. Note: If USB Virtual COM or Bluetooth SPP is selected for output interface, the host can directly send serial commands to configure the scanner. For example, run HyperTerminal.exe and type the 6-digit command located under each setup barcode. Refer to Appendix II Host Serial Commands. 10 Enter Setup Quick Start ENTER CONFIGURATION MODE For the scanner to enter the configuration mode, read the "Enter Setup" barcode, which can be located at the bottom of almost every even page of this manual. The scanner will respond with six beeps and its LED indicator will become flashing red after reading the barcode. Enter Setup For configuring scanner parameters, see Read a Setup Barcode below. EXIT CONFIGURATION MODE For the scanner to save settings and exit the configuration mode, read the Update barcode, which can be located at the bottom of almost every odd page of this manual. Exit the configuration mode without saving any changes; read the Abort barcode instead. Just like reading the Enter Setup barcode, the scanner will respond with six beeps and its LED indicator will become flashing red after reading the barcode. Wait for a few seconds for the scanner to restart itself. 11 Update Abort Update 1662/1664 Barcode Scanner User Guide DEFAULT SETTINGS SAVE USER SETTINGS AS DEFAULTS For the scanner to keep the customized settings as user defaults, you must read the Save as User Defaults barcode. This is a normal setup barcode, and the scanner will respond with two beeps (low-high tone). After reading the Update barcode, the current settings will be saved as user defaults. RESTORE USER DEFAULTS For the scanner to restore the user defaults, which you have saved earlier, you must read the Restore User Defaults barcode. This is a normal setup barcode, and the scanner will respond with two beeps (low-high tone). After reading the Update barcode, all the parameters of the scanner will return to their customized values. RESTORE SYSTEM DEFAULTS For the scanner to restore the factory defaults, read the Restore System Defaults barcode. This is a normal setup barcode, and the scanner will respond with two beeps
(low-high tone). After reading the Update barcode, all the parameters of the scanner will return to their default values. The current connection record will be cleared as well. Refer to 1.18.1 Restore System Defaults for the key combination used to restore defaults during operation. For 3610 to restore factory defaults, refer to 3610 Setup Barcodes & Serial Commands. Save as User Defaults Restore User Defaults Restore System Defaults Note: The system default value (if there is one) for each setting is indicated by an asterisk *. 12 Enter Setup Quick Start READ A SETUP BARCODE CONFIGURE PARAMETERS For most of the scanner parameters, only one read is required to set them to new values. The scanner will respond with two beeps (low-high tone) when each parameter is set successfully. Refer to Create One-Scan Setup Barcodes. But for a number of special parameters, multiple reads are required to complete the setting. In this case, the scanner will respond with a short beep to indicate it needs to read more setup barcodes. These special parameters may require reading one or more setup barcodes, such as Numeric barcodes, say, for keyboard type, inter-character delay, length qualification Hexadecimal barcodes, say, for character strings as prefix, suffix, etc. When Bluetooth HID or USB HID is configured for interface, Key Type and Key Status will then become applicable. Decide whether to change key status when Normal Key is selected for Key Type. To complete the configuration of these special parameters, it requires reading the Validate barcode, and the scanner will respond with two beeps (low-high tone) to indicate the input values are validated. 13 Update 1662/1664 Barcode Scanner User Guide The example below shows how to save your settings as User Default so that you may restore user defaults at a later time:
Steps Action Scanner Feedback if Successful 1) Power on the scanner The scanner will respond with a long beep
(high tone) and its LED indicator will become solid red and go off. The scanner will respond with six beeps
(high-low tone repeats three times), and its LED indicator will be flashing red. 2) Enter the Configuration Mode 3) Read a Setup barcode For example, The scanner will respond with two beeps
(low-high tone) if reading a normal setup barcode. 4) Exit the Configuration Mode Same as for Enter the Configuration Mode. OR 5)
The scanner will automatically restart itself Same as for Power on the scanner. When any configuration error occurs... The scanner will respond with one long beep (low tone). 14 Enter Setup Normal setup barcode Normal setup barcode Special setup barcode Decimal barcodes Quick Start The example below shows how to set numeric parameters:
Steps Action 1) Power on the scanner... 2) Enter the Configuration Mode Scanner Feedback if Successful The scanner will respond with a long beep
(high tone) and its LED indicator will become solid red and go off. The scanner will respond with six beeps
(high-low tone repeats three times), and its LED indicator will become flashing red. 3) Read a Setup barcode... For example, The scanner will respond with two beeps
(low-high tone) if reading a normal setup barcode. The scanner will respond with one short beep if reading a special setup barcode such as Max. Length, indicating the setup requires reading more barcodes. Read the Decimal Value barcode(s). Refer to Appendix IV Decimal System 4) Exit the Configuration Mode Same as for Enter the Configuration Mode. The scanner will respond with two beeps
(low-high tone) when the input values are validated. OR 5) The scanner will automatically restart itself Same as for Power on the scanner. 15 Update 1662/1664 Barcode Scanner User Guide The example below shows how to set string parameters:
Steps Action 1) Power on the scanner... 2) Enter the Configuration Mode 3) Read a Setup barcode... For example, Special setup barcodes Hexadecimal barcodes 16 Scanner Feedback if Successful The scanner will respond with a long beep
(high tone) and its LED indicator will become solid red and go off. The scanner will respond with six beeps
(high-low tone repeats three times), and its LED indicator will become flashing red. The scanner will respond with one short beep if reading a special setup barcode such as Prefix Code, indicating the setup requires reading more barcodes. When Bluetooth HID or USB HID is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to change key status when Normal Key is selected for Key Type. Refer to Appendix III Read the Hexadecimal Value barcodes for the desired character string. For example, read 2 and B for the scanner to prefix the character +. Refer to Appendix IV Hexadecimal System The scanner will respond with two beeps
(low-high tone) when the input values are validated. Same as for Enter the Configuration Mode. Enter Setup 4) Exit the Configuration Mode OR 5) The scanner will automatically restart itself Same as for Power on the scanner. Quick Start LIST THE CURRENT SETTINGS The current settings of all scanner parameters can be sent to the host computer for user inspection. The listing includes pages as shown below. You can select the page of interest by having the scanner read the List Page x barcode. The scanner will respond with two beeps (low-high tone) and send the selected page to the host immediately. List settings regarding Firmware Version, Serial Number, Interface, Buzzer, Simple Pairing Status and Other Scanner Parameters List Page 1 List settings regarding Prefix, Suffix, Code Type and Length Code Setting (1/2) List Page 2 List settings regarding Prefix, Suffix, and Length Code Setting (2/2) List Page 3 List settings regarding Code ID List Page 4 List settings regarding Readable Symbologies
(1/2) List Page 5 List settings regarding Readable Symbologies
(2/2) List Page 6 List settings regarding Symbology Parameters
(1/3) List Page 7 List settings regarding Symbology Parameters
(2/3) List Page 8 List settings regarding Symbology Parameters
(3/3) List Page 9 Reserved List Page 10 Update 17 1662/1664 Barcode Scanner User Guide List settings regarding Editing Format 1
(1/2)
(2/2)
(1/2)
(2/2)
(1/2)
(2/2)
(1/2)
(2/2)
(1/2)
(2/2) List settings regarding Editing Format 1 List settings regarding Editing Format 2 List settings regarding Editing Format 2 List settings regarding Editing Format 3 List settings regarding Editing Format 3 List settings regarding Editing Format 4 List settings regarding Editing Format 4 List settings regarding Editing Format 5 List settings regarding Editing Format 5 List current settings List Page 11 List Page 12 List Page 13 List Page 14 List Page 15 List Page 16 List Page 17 List Page 18 List Page 19 List Page 20 List Page 21 List information regarding Driver License List Page 22 18 Enter Setup CREATE ONE-SCAN SETUP BARCODES The fact is most of the scanner parameters require only one read for setting new values. To facilitate configuring the scanner, you may create One-Scan setup barcodes for use. Quick Start 1D ONE-SCAN SETUP BARCODE The requirements of a 1D One-Scan setup barcode are:
a prefix of the #@ characters the six digits of command parameters a suffix of the #character For example, the scanner needs the reading of three setup barcodes for the command parameter 109952 to take effect:
Enter Setup ge 3 List Pa e Upda t Now, it requires only one read:
One-Scan Setup Barcode for 109952 Note: The scanner will restart automatically upon reading the One-Scan setup barcode for (1) changing the interface or (2) setting memory mode, enable or disable. It will respond with a long beep and its LED will come on-off. 19 Update 1662/1664 Barcode Scanner User Guide SETUP QR CODE Users can also scan a single QR Code combining with a series of serial commands to configure the scanner. For example, if you want to change the suffix character to #, you will need to input the serial commands in sequence as follows (underlining the digits is to make them more readable):
#@CipherLab101231109902109903109994 Command Purpose
#@CipherLab Enter Setup Configure suffix Give the first hexadecimal digit of 0x23 Give the second hexadecimal digit of 0x23 for taking # as the suffix Validate the settings Setup QR Code for configuring suffix 101231 109902 109903 109994 20 Enter Setup Chapter 1 UNDERSTANDING THE BARCODE SCANNER This chapter explains the features and usage of the barcode scanner. IN THIS CHAPTER 1.1 Battery ..................................................................... 21 1.2 Memory .................................................................... 26 1.3 LED Indicator ............................................................ 30 1.4 Beeper ..................................................................... 32 1.5 Vibrator .................................................................... 36 1.6 Send NR to Host ...................................................... 37 1.7 Scan Modes .............................................................. 38 1.8 Scanning Timeout ...................................................... 44 1.9 Delay between Re-read ............................................... 45 1.10 Read Redundancy for All Symblogies ........................... 46 1.11 Addon Security for UPC/EAN Barcodes ......................... 47 1.12 Negative Barcodes ................................................... 47 1.13 Use Direct USB Cable ................................................ 48 1.14 Picklist Mode ........................................................... 49 1.15 Pager Beep Duration ................................................. 49 1.16 Time Stamp ............................................................ 50 1.17 2D Decode Setting ................................................... 54 1.18 Hardware Reset ....................................................... 55 1.19 Mobile Phone/Display Mode ....................................... 56 1.20 Serial Number Stamp ............................................... 56 1.1 BATTERY The scanner is battery-powered: Use a rechargeable 3.7 V/850 mAh Li-ion battery. For intensive data collection, please prepare spare battery or batteries for non-stop operation. Note: (1) The rechargeable battery for 1662/1664 may not be fully charged when shipped. We suggest charging it to full before use.
(2) The scanner can be configured to save battery power. Refer to settings of Auto Power Off & Power-Saving, Sniff Mode, as well as Low Battery Alarm. 21 Update 1662/1664 Barcode Scanner User Guide 1.1.1 POWER LEVEL Scan the barcode below to get the battery capacity information with each increment of 20 in percentage terms. Remaining Battery Capacity 1.1.2 HOW TO OPERATE THE SCANNER Turn on the scanner Turn off the scanner Press the [Power/Delete] key for 2 seconds. The scanner will respond with a long beep (high tone), and its LED indicator will become solid red and go off. Press the [Power/Delete] key for 2 seconds. The scanner will respond with two short beeps (high tone) and the LED will become solid red. Release the key then. Otherwise, let the scanner turn off automatically in specific circumstances. Delete the last collected data when in memory mode Press the [Power/Delete] key. The scanner will respond with two short beeps (high tone) and the LED will become solid red. Before the LED goes off (within 1 second), press the [Power/Delete] key again to confirm the deletion. Enable/Disable the [Delete] key function Scan the barcode below to enable/disable the [Delete] key. By default, users can press the
[Power/Delete] key to delete data. If the function is disabled, pressing the key to delete data is not allowed.
*Enable Disable 22 Enter Setup Chapter 1 Understanding the Barcode Scanner 1.1.3 AUTO POWER OFF & POWER-SAVING The scanner will stay active at power-on, which may be followed by a transition from full CPU speed to low CPU speed (Power-Saving) to auto shutdown (Auto Power Off). Power-Saving (1~254 min.; 0= Disable): By default, it is set to stand by at full-speed for 2 minutes before it enters low-speed mode. If this feature is not desired, set it to 0. Auto Power Off (1~254 min.; 0= Disable): By default, it is set to automatically shut down after 10 minutes. If this feature is not desired, set it to 0. Note: 1. The Power-Saving setting will still take effect once a connection has been established successfully, via Bluetooth HID or SPP. There will be a time delay to reactivate 2D scan engine when scanner comes back from power off mode. 2. Before establishing a WPAN connection successfully 1) The scanner will stay active for a specified period of time (2 minutes by default) for the following scenarios. Its CPU is running at full speed, and the LED is flashing blue (On/Off ratio 0.5 s: 0.5 s).
(a) waiting for a connection request from the host (Bluetooth SPP Slave Mode)
(b) trying to connect to the host (Bluetooth HID or Bluetooth SPP Master Mode)
(c) trying to connect to 3610 2) If it fails to connect within 2 minutes, the scanner will become inactive to save power for the remaining period of time (the specified value minus 2 minutes). Its CPU is running at low speed, and the LED is flashing red (On/Off ratio 0.3 s: 2.5 s). Press the [Trigger] key to wake up the scanner when it becomes inactive, and the scanner will stay active again. 3) If it fails to connect again and again, and finally stays inactive until the specified time interval for Auto Power Off has elapsed, the scanner will automatically turn off in order to conserve battery power. Hold down the [Power/Delete] key for 2 seconds to turn it on. Note: For scenarios (a) and (b) in step 1, on your computer you may need to search for the scanner again. 23 Update 1662/1664 Barcode Scanner User Guide After establishing a WPAN connection successfully 1) Once a WPAN connection is established successfully, the scanner will stay active for a specified period of time (2 minutes by default) for data transmission. Its CPU is running at full speed, and the LED is flashing blue (On/Off ratio 0.02 s: 3 s). 2) If it is idle within 2 minutes, the scanner will become inactive to save power for the remaining period of time (the specified value minus 2 minutes). Its CPU is running at low speed, and the LED is flashing red (On/Off ratio 0.3 s: 2.5 s). Press the [Trigger] key to wake up the scanner when it becomes inactive, and the scanner will stay active again. 3) If it is idle and finally stays inactive until the specified time interval for Auto Power Off has elapsed, the scanner will automatically turn off in order to conserve battery power. The three short beeps will ring out, with tone descending from high to low. Hold down the [Power/Delete] key for 2 seconds to turn it on. For Bluetooth HID, the scanner will resume connection with the host upon powering on again, as long as the host application is running. The three short beeps will ring out, with tone ascending from low to high. If the scanner fails to resume connection, it will try every 5 seconds to re-connect to the host unless the Reset Connection barcode has been scanned. For Bluetooth SPP Slave Mode, the scanner must wait for the host to re-connect. For Bluetooth SPP Master Mode, the scanner will resume connection with the host upon powering on again, as long as the host application is running. The three short beeps will ring out, with tone ascending from low to high. If the scanner fails to resume connection, it will try every 5 seconds to re-connect to the host unless the Reset Connection or Restore System Defaults barcode has been scanned. With the use of 3610, the scanner will try re-connecting to 3610 whilst the scanner is active. 24 Enter Setup Chapter 1 Understanding the Barcode Scanner Auto Off after 0~254 min. (*10) 1) Read the barcode above to specify the time interval in minutes before the scanner automatically turns off. 2) Read the Decimal Value barcode on page 271. For example, read 1 and 5 for the scanner to automatically turn off after being idle for 15 minutes. 3) Read the Validate barcode on the same page to complete this setting. Note: Auto Power Off will not take effect when the scanner is in the configuration mode. Power-Saving after 0~254 min. (*2) 1) Read the barcode above to specify the time interval in minutes before the scanner enters low-speed mode. 2) Read the Decimal Value barcode on page 271. For example, read 5 for the scanner to enter low-speed mode after being idle for 5 minutes. 3) Read the Validate barcode on the same page to complete this setting. Note: Power-Saving will not take effect when one of the following conditions is met:
(1) The scanner is in the configuration mode.
(2) The Power-Saving value is set to 0.
(3) The scan mode is set to Continuous or Alternate Mode.
(4) The setting value of Power-Saving is greater than that of Auto Power Off. 25 Update 1662/1664 Barcode Scanner User Guide 1.2 MEMORY The scanned data can be sent to a host computer immediately via the WPAN connection or stored in flash memory when the scanner is set to Memory mode. 1.2.1 TRANSMIT BUFFER By default, the transmit buffer is enabled and ready for use when the scanner is out of range. Upon reading a barcode successfully within range, the scanner responds with one short beep (high tone) and its LED indicator becomes solid green and goes off. However, the host computer may not receive the data immediately if the scanner is out of range. With the 10 KB transmit buffer, the scanner can ignore the transmission status and keep on reading barcodes until the buffer is full. When transmit buffer is enabled If the scanner is out of range, it will respond with two short beeps, high-low tone, upon reading a barcode successfully. When transmit buffer is full, the scanner will respond with one long beep (low tone) and its LED indicator will become solid red and go off. You are advised to get back into range. When transmit buffer is disabled If the scanner is out of range, it will respond with one long beep (low tone) and its LED indicator will become solid red and go off. You are advised to get back into range.
*Enable Disable Note: The 10 KB transmit buffer on the scanner can hold as many as 640 scans based on EAN-13 barcodes. Data will be cleared out once the scanner is turned off or running out of battery power!
CONTINUOUS DECODING The scanner only proceeds with the next decode after the host computer has successfully received data. In case of transmitting a huge mass of 2D barcode data, users may encounter difficulties in keeping decoding barcodes. Enabling this function can have the scanner keep decoding without waiting for the host to complete the data receiving. 26 Enter Setup Chapter 1 Understanding the Barcode Scanner 1.2.2 MEMORY MODE When the scanner is in memory mode, it means any real-time connection established with the host is disabled. 1662/1664 scanner keeps 4MB flash memory for memory mode operation, which can store over 240,000 scans based on EAN-13 barcodes. Warning: No real-time connection is allowed unless the memory mode is disabled. Memory Data Delay You may set a delay between each data record while transmitting data back to the host.
*Enable Disable Enable
*Disable
*None 250 ms 500 ms 1 sec Update 27 1662/1664 Barcode Scanner User Guide 28 2 sec 3 sec 5 sec 8 sec Send Data When the memory is used up, the scanner will respond with two short beeps (high-low tone) as a warning. It is advised to send data to the host immediately by having the scanner read the Send Data barcode below. 1662/1664 can send data via Direct USB interface once the computer has found the USB connection. Refer to 1.13 Use Direct USB Cable. Because the time-out value is set to 0 by default, connect the cable before having the scanner read the Send Data barcode. Otherwise, the scanner will try to temporarily resume the previous WPAN connection with the host, if there is any. During transmission of data collected in memory mode, if the transmission fails, the scanner will flash red (On/Off ratio 0.2 s: 0.2 s) after responding with two short beeps (high-low tone) and go back to previous working mode. Press trigger or power key to stop flashing. Send Data Send Data Time-out If a time-out value other than zero is given, it will first try to send data via Direct USB interface within the specified period of time. Connect the cable before it times out. When the attempt fails, it will try to temporarily resume the previous WPAN connection with the host, if there is any. If 1662/1664 has never been connected to the host cordless, it will not be able to send data until it is connected using the Direct USB cable!
Send Data Time-Out after 0~15 sec.
(*0) Clear Data & Confirm Even though data has been sent to the host, the flash memory is still occupied unless you erase the memory by reading two barcodes Clear Data and Confirm. 1) Read the Clear Data barcode to clear the flash memory. 2) Read the Confirm barcode to confirm the action. Enter Setup Chapter 1 Understanding the Barcode Scanner Clear Data Confirm 1.2.3 FREE MEMORY You can scan the barcode below to show the available capacity of the flash memory in percentage terms. 1.2.4 RECORD COUNT OF MEMORY You can scan the barcode below to show the data record count of the flash memory. 29 Available Memory Data Record Count of Memory Update 1662/1664 Barcode Scanner User Guide 1.3 LED INDICATOR The triple-color LED on top of the scanner is used to provide feedback. For example, the LED becomes solid red and goes off upon powering on or running out of transmit buffer. You may tell the difference by the beeps you will hear a long beep of high tone when powering on the scanner, and a long beep of low tone when the transmit buffer becomes full. Scanner LED Red, on-off Meaning second)
Power on, with one long beep (high tone, LED on for 1 Data saved to buffer when transmit buffer is enabled and the scanner is out of range, with two short beeps (high-low tone) Transmit buffer full, with one long beep (low tone) Transmit buffer disabled, with one long beep (low tone) Delete the last collected data in memory mode, with two short beeps (high tone, LED on for 1 second) Memory full in memory mode, with two short beeps (high-low tone) Flashing red (On/Off ratio 0.3 s: 2.5 s) indicates the scanner is inactive and its CPU running at low speed to save power
(because no WPAN connection is established after waiting for two minutes) Configuration Mode (On/Off ratio 0.5 s: 0.5 s) Red, flashing
Red, flashing
Flashing red 5 times indicates low battery when trying to get into download mode. The task is aborted. Green, on-off Good Read, with one short beep (high tone) and beeper pitch and duration programmable Green, flashing Flashing green (On/Off ratio 0.5 s: 0.5 s) indicates the scanner is fully charged. Blue, flashing
First, flashing blue (On/Off ratio 0.5 s: 0.5 s) for two minutes indicates the scanner is waiting for connection, and goes off if no connection is established, then flashing red (On/Off ratio 0.3 s:
2.5 s) indicates the scanner is inactive. It is ready for connection only while the LED is flashing blue SPP Slave: waiting host to connect HID or SPP Master: trying to connect to host Using 3610: trying to connect to 3610 Blue, flashing
Flashing blue (On/Off ratio 0.1 s: 0.1 s) indicates the scanner receives a PIN code request from host (flashing more quickly than waiting connection). Blue, flashing
Flashing blue (On/Off ratio 0.02 s: 3 s) indicates the scanner has established a WPAN connection successfully. Blue, flashing Green, flashing Flashing blue and green (On/Off ratio 0.1 s: 0.1 s) indicates an error occurs while entering the PIN code. Press the [Trigger] key
30 Enter Setup Chapter 1 Understanding the Barcode Scanner to try and re-connect. Red, flashing Red, flashing Red, flashing Red, flashing
1.3.1 GOOD READ LED Flashing red (On/Off ratio 0.2 s: 0.2 s) indicates the scanner has failed to transmit data stored in memory. Press any key to stop flashing. Accompanied with beeping, flashing red for three times indicates the present scanner battery capacity is running low. This happens at one-minute intervals. After a good read, flashing red for three times indicates the present scanner battery capacity is running low. When scanning the Download barcode, flashing red for five times indicates the present scanner battery voltage is below 3.7v and the scanner wont get into Download mode. 1.3.2 GOOD READ LED DURATION By default, the Good Read LED stays on for 40 milliseconds. Specify a value, ranging from 1 to 254 in units of 10 milliseconds. 1) Read the barcode above to specify the time interval before the Good Read LED goes off. 2) Read the Decimal Value barcode on page 271. For example, read 1 and 5 for the LED to go off after 150 milliseconds. 3) Read the Validate barcode on the same page to complete this setting.
*Enable Good Read LED Disable Good Read LED Good Read LED Time-out after 0.01~2.54 sec.
(*40 ms) Update 31 1662/1664 Barcode Scanner User Guide 1.4 BEEPER The scanner has a buzzer to provide feedback in various operating conditions. Beeping Meaning One long beep, high tone One long beep, low tone Power on, with red LED on (1 second) and off quickly Transmit buffer full, with red LED on-off Transmit buffer disabled, with red LED on-off Configuration error (Wrong barcode) PIN code input error Reject random PIN request Failed to send data in memory mode Good Read, with green LED on-off More setup barcodes required Input PIN code Clear PIN code More barcodes required to complete the output sequence requirements of Multi-Barcode Editor, with green LED on-off
(Upon completion, same as Good Read.) Enter Configuration Mode, with red LED flashing Exit Configuration Mode Setup barcode read successfully Low Battery Alarm Power off, with red LED on (until the key is released) Delete the last collected data in memory mode, with red LED on (1 second) and off Waking up the scanner depends on the paging setting value until the power key is pressed or the sleeping time out is reached Data saved to buffer when transmit buffer is enabled and the scanner is out of range, with red LED on-off Memory Mode Memory full, with red LED on-off Memory Mode Transmission failed, with red LED flashing One short beep, high tone Programmable, default to 4 KHz One short beep, high tone One short beep, low tone Six short beeps High-low tone repeats three times Two short beeps, low-high tone Two short beeps, high tone Two short beeps, high-low tone One short beep then one long beep, high-low tone Indicates low battery when trying to get into download mode. The task is aborted. Two long beeps, high-low tone Multi-Barcode Mode Buffer full Three short beeps, tone descending from high to low Three short beeps, tone ascending WPAN connection established, with blue LED flashing WPAN connection out of range or suspended 32 Enter Setup Chapter 1 Understanding the Barcode Scanner from low to high WPAN connection resumed, with blue LED flashing 1.4.1 BEEPER VOLUME Mute Minimum Volume Medium Volume
*Maximum Volume 33 Update 1662/1664 Barcode Scanner User Guide 1.4.2 GOOD READ BEEP Frequency Duration 34 8 kHz
*4 kHz 2 kHz 1 kHz
*Shortest Shorter Longer Longest Enter Setup Chapter 1 Understanding the Barcode Scanner 1.4.3 LOW BATTERY ALARM By default, the beeper is enabled to give a warning when the battery charge gets low. In order to prevent data loss, you are advised to replace the battery immediately when you hear two short beeps (high tone). Low Battery Alarm Time Interval Description 1.5 seconds 10 seconds During scanner operation The scanner idles for 30 seconds 1.4.4 BELL RING With this function enabled, the scanner will produce a bell ring when receiving the 0x07 character which is sent via BT SPP Slave, BT SPP Master, RS232 via BT cradle, VCOM via BT cradle, or VCOM CDC via BT cradle interface. Disable (No Alarm)
*Enable Low Battery Alarm Enable
*Disable Update 35 1662/1664 Barcode Scanner User Guide 1.5 VIBRATOR 1.5.1 GOOD READ VIBRATOR Enable Good Read Vibrator
*Disable Good Read Vibrator Good Read Vibrator Time-out after 0.1~25.4 sec.
(*1 s) 1.5.2 GOOD READ VIBRATOR DURATION By default, the Good Read Vibrator stays on for 1 second. Specify a value, ranging from 1 to 254 in units of 100 milliseconds. 1) Read the barcode above to specify the time interval, in tenths of seconds before the Good Read Vibrator goes off. 2) Read the Decimal Value barcode on page 271. For example, read 1 and 5 for the vibrator to vibrate after 1.5 seconds good read. 3) Read the Validate barcode on the same page to complete this setting. 36 Enter Setup Chapter 1 Understanding the Barcode Scanner 1.6 SEND NR TO HOST The scanner can send a NR string to the host to notify a No Read event. Enable
*Disable 37 Update 1662/1664 Barcode Scanner User Guide 1.7 SCAN MODES Different scan modes are supported select the scan mode that best suits the requirements of a specific application. Refer to the comparison table below. Scan Mode Start to Scan Stop Scanning Always Press trigger once Hold trigger Press trigger twice Release trigger Release trigger Press trigger once Barcode being read Timeout Laser mode Auto Off mode Auto Power Off mode Aiming mode
(1664 only) Multi-Barcode mode Continuous mode
(1662 only) Alternate mode
(1662 only) Multicode mode
(1664 only) Release Mode Note: By default, the scan mode is set to Laser mode. 38 Enter Setup Chapter 1 Understanding the Barcode Scanner 1.7.1 LASER MODE The scanner will start scanning once the trigger is held down. The scanning won't stop until (1) a barcode is decoded, (2) the pre-set timeout expires, or (3) you release the trigger. Note: Refer to 1.8 Scanning Timeout. 1.7.2 AUTO OFF MODE The scanner will start scanning once the trigger is pressed. The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout expires. Note: Refer to 1.8 Scanning Timeout. 1.7.3 AUTO POWER OFF MODE The scanner will start scanning once the trigger is pressed. The scanning won't stop until the pre-set timeout expires, and, the pre-set timeout period re-counts after each successful decoding. Note: Refer to 1.9 Delay between Re-read and 1.8 Scanning Timeout.
*Laser Mode Auto Off Mode Auto Power Off Mode Update 39 1662/1664 Barcode Scanner User Guide 1.7.4 AIMING MODE (1664 ONLY) The scanner will aim at a barcode once the trigger is pressed, and start scanning when the trigger is pressed again within one second. The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout expires. Aiming Timeout Aiming Mode Aiming Time-out after 1~15 sec.
(*1) You can limit the aiming time interval (1~15). By default, the scanner time-out is set to 1 second. 1) Read the barcode above to specify the time interval in seconds before aiming ends. (It is set to 1 by default.) 2) Read the Decimal Value barcode on page 271. For example, read 1 and 0 for the scanner to automatically shut down after being idle for 10 seconds. 3) Read the Validate barcode on the same page to complete this setting. 1.7.5 MULTI-BARCODE MODE The scanner will be scanning as long as the trigger is held down, capable of decoding one single barcode, as well as multiple unique barcodes one at a time. While decoding a bunch of unique barcodes, if a barcode is decoded twice, its subsequent decoding will be ignored and the scanner is expecting another unique barcode. The scanning won't stop until you release the trigger. Multi-Barcode Mode Note: (1) A barcode is considered unique when its Code Type or data is different from others.
(2) Multi-Barcode Mode is not related to the 5.6 Multi-Barcode Editor. 40 Enter Setup Chapter 1 Understanding the Barcode Scanner 1.7.6 CONTINUOUS MODE (1662 ONLY) The scanner is always scanning. After a successful decoding, the removal of barcode is required. It is not allowed to proceed to decode until the decoding delay time has passed. To decode the same barcode repeatedly, move away the barcode and put it back again and again for scanning. Note: Refer to 1.9 Delay between Re-read. Decoding Delay Set the time interval between each decoding. Continuous Mode
*Disable 0.5 sec 1 sec 2 sec Alternate Mode Update 41 1.7.7 ALTERNATE MODE (1662 ONLY) The scanner will start scanning once the trigger is pressed The scanning won't stop until you press the trigger again. 1662/1664 Barcode Scanner User Guide 1.7.8 MULTICODE MODE (1664 ONLY) This mode is designed to decode multiple barcodes at one time. The scanning starts as long as the trigger is pressed down, capable of decoding multiple barcodes based on the arranged multicode settings (refer to ScanMaster user guide). The multicode settings define the barcode(s) that the scanner can expect to find in an image. And the scanner reports a successful decode only if it decodes all barcodes indicated by the multicode settings, otherwise the decode fails. Barcodes are transmitted in the order defined in the multicode settings. The scanning won't stop until (1) a barcode is decoded, (2) the pre-set timeout expires, or (3) you release the trigger. Scan the barcode below to enter Multicode mode. Multicode Mode Note: While in Multicode mode, users can press the trigger five times within 1.5 seconds to switch the scanner to Laser mode. Wait for three seconds to attempt to switch again if you fail. Scanning the Enter Setup barcode or rebooting can have the scanner back to Multicode mode. Select the level of reading security. For example, If "No Redundancy" is selected, one successful decoding will make the reading valid and induce the "READER Event". If "Three Times" is selected, it will take a total of four consecutive successful decoding of the same barcode to make the reading valid. The higher the reading security is (that is, the more redundancy the user selects), the slower the reading speed gets. It is obvious that the more redundancy selected, the higher the reading security is, and thus, the slower the reading speed becomes. You have to compromise between reading security and decoding speed. 42
*No Redundancy One Time Enter Setup Chapter 1 Understanding the Barcode Scanner Two Times Three Times Enable Same Barcode Allowance
*Disable Same Barcode Allowance Scan the barcode below to enable the Same Barcode Allowance function which increases decoding by one time automatically. 1.7.9 RELEASE MODE The scanner will aim at a barcode once the trigger is pressed, and then start scanning when the trigger is released. Note: Refer to 1.8 Scanning Timeout. 43 Release Mode Update Specify the scanning time interval (1~254 sec.; 0= Disable) when the scan mode is set to any of the following 1662/1664 Barcode Scanner User Guide 1.8 SCANNING TIMEOUT Laser mode Auto Off mode Auto Power Off mode Aiming mode (1664 Only) Multicode mode (1664 Only) Release mode Scanner Time-out after 0~254 sec.
(*10) 1) Read the barcode above to specify the time interval in seconds before the scan engine times out. 2) Read the Decimal Value barcode on page 271. For example, read 1 and 5 for the scanner to shut down automatically after being idle for 15 seconds. 3) Read the Validate barcode on the same page to complete this setting. 44 Enter Setup Chapter 1 Understanding the Barcode Scanner 1.9 DELAY BETWEEN RE-READ This is also referred to as the Blocking Time, which is used to prevent the scanner from accidentally reading the same barcode twice when the scan mode is set to any of the following Auto Power Off mode Continuous mode (1662 only) Alternate mode (1662 only) Laser mode (1664 only with the Auto-sense function working) 100 ms 200 ms
*400 ms 800 ms 1 sec 2 sec 3 sec 5 sec Update 45 1662/1664 Barcode Scanner User Guide 1.10 READ REDUNDANCY FOR ALL SYMBLOGIES Select the level of reading security. For example, If "No Redundancy" is selected, one successful decoding will make the reading valid and induce the "READER Event". If "Two Times" is selected, it will take a total of three consecutive successful decoding of the same barcode to make the reading valid. The higher the reading security is
(that is, the more redundancy the user selects), the slower the reading speed gets. It is obvious that the more redundancy selected, the higher the reading security is, and thus, the slower the reading speed becomes. It has to compromise between reading security and decoding speed.
*No Redundancy One Time Two Times 46 Enter Setup Chapter 1 Understanding the Barcode Scanner 1.11 ADDON SECURITY FOR UPC/EAN BARCODES The scanner is capable of decoding a mix of UPC/EAN barcodes with or without addons. The read redundancy (2~30 times) allows changing the number of times to decode a UPC/EAN barcode before transmission. The more redundancy selected, the higher the reading security is, and thus, the slower the reading speed becomes. Note: UPC/EAN Addon 2 and Addon 5 must be enabled individually for this setting to take effect. Addon Security Level
(2~30; default 10) 1) Read the barcode above to specify the read redundancy for UPC/EAN barcodes. 2) Read the Decimal Value barcode on page 271. For example, read 1 and 2 for the scanner to re-read the barcode for 12 times. 3) Read the Validate barcode on the same page to complete this setting. 1.12 NEGATIVE BARCODES (1664 ONLY) Normally, barcodes are printed with the color of the bars darker than that of the spaces. But for negative barcodes, they are printed in the opposite sense just like negative films. The spaces of negative barcodes are printed with a color darker than that of the bars. Configure the scanner to be able to read negative barcodes if required. 47 Enable
*Disable Update 1662/1664 Barcode Scanner User Guide 1.13 USE DIRECT USB CABLE 1662/1664 supports Direct USB interface for charging the battery and/or sending data to the host in memory mode. Refer to 1.2.2 Memory Mode. Note: The scanner will not function when it is solely on USB power and without a battery loaded. 1.13.1 DIRECT USB INTERFACE When it is set to Memory Mode and connected to computer via the Direct USB cable, the default output interface becomes Direct USB Virtual COM, change it to Direct USB HID if required. For details on configuring the interface settings, refer to the following sections:
2.6 Direct USB HID 2.7 Direct USB Virtual COM 1.13.2 DISABLE DIRECT USB INTERFACE When connecting the USB cable to the scanner for charging the battery, ensure the Disable Direct USB barcode has been scanned to avoid sending data to the host in memory mode. In this mode the USB cable function will be charging the battery only.
*Activate Direct USB Virtual COM Activate Direct USB HID Disable Direct USB 48 Enter Setup Chapter 1 Understanding the Barcode Scanner 1.14 PICKLIST MODE (1664 ONLY) Picklist mode enables the decoder to decode only the barcodes aligned under the center of the laser aiming pattern. 1.15 PAGER BEEP DURATION Paging function is only activated when 1662/1664 is in Power-Saving mode. 1662/1664 can be woken up via receiving any Bluetooth status command by pressing a key on the host keyboard. The buzzer will continuously sound two short high tone beeps until the power key is pressed on the scanner or the timeout is reached, and the scanner re-
enters power saving mode. By default, the pager beep duration is 5 seconds. Specify a value, ranging from 0 to 15.
(0~15 sec.; 0= Disable) Bluetooth HID profile: Press any one of the following keys Scroll Lock, Number Lock or Caps Lock on the host computer to trigger the waking up of 1662/1664. Bluetooth SPP Profile: Any command sent using Bluetooth SPP will trigger the waking up of 1662/1664. Pager Beep Duration 0~15 sec.
(*5 s) 1) Read the barcode above to specify the desired beep active time. 2) Read the Decimal Value barcode on page 271. For example, read 1 and 5 for the pager beep function to be activated each 15 seconds after entering Power-Saving mode. 3) Read the Validate barcode on the same page to complete this setting. Enable
*Disable Update 49 1662/1664 Barcode Scanner User Guide 1.16 TIME STAMP No Time Stamp Add Time Stamp in front of data Add Time Stamp to the end of data Specify time stamp format added to the prefix or suffix of a data. Up to three settings can be configured:
If added in front of data, it means prior to the prefix field. Alternatively, to the end of data. 1.16.1 DATE AND TIME SETTINGS Read the barcode below to enable/disable Date and Time function. No Time Stamp
*Disable Add Time Stamp in front of Data Add Time Stamp to the end of Data Year Output
*Enable Year Output Disable Month Output
*Enable Month Output Disable 50 Enter Setup Chapter 1 Understanding the Barcode Scanner Date Output
*Enable Date Output Disable Hour Output
*Enable Hour Output Diable Minute Output
*Enable Minute Output Disalbe Second Output
*Enable Second Output Diable Update 51 1662/1664 Barcode Scanner User Guide Decoding Data and Time 52 1) Read the barcode above to apply time or date code separately, and follow steps 2~3. 2) Read the Decimal Value barcode on page 271 for the desired character string. For example:
Year: Read 2, 0, 1, 1 for the year setting as year=2011. Date: Read 1, 1, 2, 0 for the date setting as date=Nov.20. Time: Read 1, 8, 5, 9 for the time setting as time=18:59. 3) Read the Validate barcode for each setting on the same page. 1.16.2 SEPARATOR FOR DATE AND TIME The Date and Time can be split with a pre-selected separator, for example, / as YYYY/MM/DD or : as HH:MM:SS Setup Year Setup Date Setup Time Separator for Date/Time
Separator for Month/Date
Separator for Hour/Minute
1) Read the barcode above to apply separator to date or time separately, and follow steps 2~3. 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. For example, read 3 and A for the separator to split the data with character [:]. 3) Read the Validate barcode on the same page to complete this setting. Enter Setup Chapter 1 Understanding the Barcode Scanner 1.16.3 DATE FORMAT The date format includes year, month and day. There are three kinds of combinations can be configured to specify Year, Month and Day:
Year/Month/Day (YYYY/MM/DD) or (YY/MM/DD) Month/Day/Year (MM/DD/YYYY) or (MM/DD/YY) Day/Month/Year (DD/MM/YYYY) or (DD/MM/YY) About Year Format:
Year format can be pre-selected as 2-digit or 4-digit. For example, if year format is YYYY, the output year is 2011 for 4-digit, alternatively is 11 for 2-digit.
*Year for 4-digit Year for 2-digit
*Year/Month/Day Month/Day/Year Day/Month/Year Update 53 1662/1664 Barcode Scanner User Guide 1.17 2D DECODE SETTING (1664 ONLY) 1.17.1 AIMING PATTERN Enable/Disable the aiming pattern during scanning.
*Enable Disable
*Enable Disable 1.17.2 DECODING ILLUMINATION Enable/Disable illumination during scanning. Enabling illumination usually results in superior images. The effectiveness of the illumination decreases as the distance to the target increases. 1.17.3 ILLUMINATION BRIGHTNESS Specify the illumination brightness level ranging from 1 to 10 for the 2D reader. The default value is 10 which represents 100% illumination brightness. Set Illumination Brightness Level for 2D Reader 1~10 (*10) 1) Read the barcode above to configure the illumination brightness. 2) Read the Decimal Value barcode on page 271 for the desired setting value. 3) Read the Validate barcode to complete this setting. 54 Enter Setup Chapter 1 Understanding the Barcode Scanner 1.18 HARDWARE RESET 1.18.1 RESTORE SYSTEM DEFAULTS In addition to scanning the Restore System Defaults barcode, the following procedure using key combinations, can be used to restore the system defaults during operation. 1) Hold down the [Power/Delete] key. 2) When the scanner responds with two short beeps (high tone), press the [Trigger] key for 5 seconds. The scanner LED indicator becomes solid red and then goes off. 3) When the scanner responds with a long beep (high tone), release the keys. Its LED indicator becomes solid red and goes off. Note: The scanner will restart itself automatically. 1.18.2 RESET CONNECTION When the output interface is Bluetooth HID or Bluetooth SPP Master, the scanner will attempt to maintain an established connection. To stop such re-connection, read the Reset Connection or Restore System Defaults barcode to clear the current connection record. Alternatively, use the key combination as described below to reset connection during operation. 1) Hold down the [Trigger] key, and then press the [Power/Delete] key for at least 5 seconds. 2) The scanner will respond with two short beeps (high tone). Wait until the scanner responds with a long beep (high tone), and then release the keys. Note: After resetting connection by hardware, the scanner will not restart itself automatically. It will resume to its previous operation except no connection. 1.18.3 DISABLE HARDWARE RESET By default, the key combination for hardware reset (including system defaults restoration and connection reset) is enabled. Users can decide whether to enable/disable the key combination. 55
*Enable Disable Update 1662/1664 Barcode Scanner User Guide 1.19 MOBILE PHONE/DISPLAY MODE By default this mode is disabled. There is a big improvement in reading barcodes displayed on mobile phones and electronic displays when this mode is enabled. 1.20 SERIAL NUMBER STAMP Decide whether to add the device serial number in front of the data transmitted. Enable
*Disable Add serial number in front of data
*Disable Specify the separator character 1.20.1 SEPARATOR BETWEEN SERIAL NUMBER STAMP AND DATA Scan the barcode below to specify the separator character between device serial number and the accompanying data. By default, the separactor is a comma symbol. 1) Read the barcode above to specify a separator character. 2) Read the Hexadecimal Value barcode on page 272 for the desired character. 3) Read the Validate barcode to complete this setting. 56 Enter Setup Chapter 2 SELECTING OUTPUT INTERFACE In order to establish a proper connection between host computer and the scanner, we suggest following these instructions 1) Install battery and hold down the [Power/Delete] key for 2 seconds to turn on the scanner. 2) Read the Enter Setup barcode to enter the configuration mode. 3) Read the associated barcodes to activate the desired interface. 4) See the following sections for output interfaces supported. 5) Read the barcodes for related settings. 6) Read the Update barcode to exit the configuration mode. 7) Turn on host computer or laptop and establish a WPAN connection with the scanner. Refer to Chapter 3 Setting up a WPAN Connection. Note: (1) By default, the output interface is set to Bluetooth HID.
(2) When set to Memory Mode and connected to computer via the Direct USB cable, the default output interface becomes Direct USB Virtual COM. IN THIS CHAPTER 2.1 Bluetooth HID .......................................................... 58 2.2 Bluetooth SPP Slave .................................................. 72 2.3 Bluetooth SPP Master ................................................ 74 2.4 USB HID via 3610 ...................................................... 79 2.5 USB Virtual COM via 3610 ........................................... 89 2.6 Direct USB HID .......................................................... 92 2.7 Direct USB Virtual COM .............................................. 103 57 Update 1662/1664 Barcode Scanner User Guide 2.1 BLUETOOTH HID For Bluetooth HID, refer to Chapter 3 Setting up a WPAN Connection for related connection settings. The scanned data will be transmitted to the computer. To capture the data run any text editor on your computer. HID Settings Keyboard Type Alphabet Layout Numeric Layout Capital Lock Type Capital Lock State Alphabet Transmission Numeric Transmission Kanji Transmission Alternate Composing Inter-Character Delay Inter-Function Delay Defaults PCAT (US) Normal Normal Normal Off Disable No 0 (ms) 0 (ms) Case-sensitive Alphanumeric keypad 58 Enter Setup Chapter 2 Selecting Output Interface 2.1.1 ACTIVATE BLUETOOTH HID & SELECT KEYBOARD TYPE When Bluetooth HID interface is activated, you will have to select a keyboard type to complete this setting. By default, Bluetooth HID is activated on the scanner, and the keyboard type is set to PCAT (US). Activate Bluetooth HID & Select Keyboard Type 1) Read the barcode above to activate Bluetooth HID and select a keyboard type. 2) Read the Decimal Value barcode on page 271. Refer to the table below for the number of desired keyboard type. 3) Read the Validate barcode on the same page to complete this setting. Note: If this interface is not activated, you can also simply have the scanner read the one-scan setting barcode to activate BT HID and select keyboard type. Please refer to Appendix VI - Bluetooth HID. Bluetooth HID By default, the keyboard type is set to PCAT (US). The following keyboard types are supported for PC No. Keyboard Type (PCAT) No. Keyboard Type (PCAT) 64 PCAT (US) 65 PCAT (French) 66 PCAT (German) 67 PCAT (Italian) 68 PCAT (Swedish) 70 PCAT (UK) 71 PCAT (Belgium) 72 PCAT (Spanish) 73 PCAT (Portuguese) 74 PS55 A01-2 (Japanese) 75 User-defined table 76 PCAT (Turkish) 77 PCAT (Hungarian) 79 PCAT (Danish) 80 PCAT (Dutch) 87 PCAT (Brazilian Portuguese) 69 PCAT (Norwegian) 78 PCAT (Swiss German) 59 Update 1662/1664 Barcode Scanner User Guide The following keyboard types are supported for Apple No. Keyboard Type (Apple) No. Keyboard Type (Apple) 64 Apple (US) 65 Apple (French) 66 Apple (German) 67 Apple (Italian) 68 Apple (Swedish) 69 Apple (Norwegian) 72 Apple (Spanish) 78 Apple (Swiss German) 79 Apple (Danish) 80 Apple (Dutch) 81 Apple (Greek) 82 Apple (Hebrew) 83 Apple (Russian) 84 Apple (Flemish) 73 Apple (Portuguese) 85 Apple (Arabic) 75 User-defined table 86 Apple (Austria German) 76 Apple (Turkish) 87 Apple (Brazilian Portuguese) Note: 81/82/83/85 keyboard types dont support English input. 2.1.2 RESET CONNECTION For Bluetooth HID, you can only have the scanner connected to one computer at a time. If you want to connect the scanner to another host, you must read the Reset Connection barcode so that the current connection record will be cleared. Then, the scanner will restart itself automatically. Go through the process in 3.2.3 Connect to Dongle to establish a new connection. Refer to 1.18 Hardware Reset. Reset Connection Note: The Restore System Defaults barcode will also clear the current connection record. 60 Enter Setup Chapter 2 Selecting Output Interface 2.1.3 KEYBOARD SETTINGS Alphabet Layout Numeric Layout Capital Lock Type Capital Lock Setting Alphabet Transmission Numeric Transmission Kanji Transmission Alternate Composing Note: Bluetooth HID does not support these functions on PDAs (1) Capital Lock Setting: Auto Detection (2) Numeric Transmission: Numeric Keys Alphabet Layout By default, the alphabet layout is set to normal mode, also known as the standard English layout. Select French or German keyboard layout if necessary. The scanner will make adjustments when sending the "A", "Q", "W", "Z", "Y", and "M" characters according to this setting. Note: This setting only works when the keyboard type selected is US keyboard, such as PCAT (US). The Alphabet Layout and Numeric Layout setting must match your keyboard. 61
*Normal AZERTY QWERTZ Update 1662/1664 Barcode Scanner User Guide US Keyboard Style Normal QWERTY layout, which is normally used in western countries. Select Lower Row for the Numeric Layout setting because the upper row is for special characters. French Keyboard Style AZERTY French layout; see below for French Keyboard Style. Select Upper Row for the Numeric Layout setting because the lower row is for special characters. German Keyboard Layout QWERTZ German layout; see below for German Keyboard Style. Select Lower Row for the Numeric Layout setting because the upper row is for special characters. 62 Enter Setup Chapter 2 Selecting Output Interface Select a proper layout that matches the alphabet layout. The scanner will make adjustments according to this setting. Numeric Layout Options Normal Lower Row Upper Row Description Depends on the [Shift] key or [Shift Lock] setting For QWERTY or QWERTZ keyboard For AZERTY keyboard
*Normal Upper Row Lower Row
*Normal Shift Lock Update Note: This setting is to be used with the Character Substitution setting when support for certain keyboard types (languages) is unavailable but required. In order to send the alphabet with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabet being transmitted. Capital Lock Type & Setting Cap Lock Type Description Normal Normal type Capital Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys. Shift Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. In addition, this affects the number or punctuation keys. 63 1662/1664 Barcode Scanner User Guide Capital Lock Capital Lock State Description Capital Lock OFF Capital Lock ON Auto Detection
(Suggested use most applications) for Assuming that the status of Caps Lock on the keyboard is OFF, transmitted characters are exactly the same as in the barcode (when
"case-sensitive" is selected for Alphabet Transmission). Assuming that the status of Caps Lock on the keyboard is ON, transmitted characters are exactly the same as in the barcode (when "case-sensitive"
is selected for Alphabet Transmission). Refer to the Capital Lock Type above. The scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted; transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabet Transmission). This setting is not supported on PDAs. Auto Detect Capital Lock ON
*Capital Lock OFF 64 Enter Setup Chapter 2 Selecting Output Interface Alphabet Transmission By default, the alphabet transmission is case-sensitive, meaning that the alphabet will be transmitted according to the original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabet transmitted according to the status of Caps Lock on the keyboard only. Ignore Case
*Case-sensitive Refer to 5.1 Letter Case. 65 Update 66 1662/1664 Barcode Scanner User Guide Numeric Transmission By default, the alphanumeric keypad is used for transmitting digits. Select Numeric Keypad if you wish to use the keys on the numeric keypad. Numeric Key
*Alphanumeric Key Note: If you select Numeric Keypad, the Num Lock status of the physical keyboard should be ON. This setting is not supported on PDAs. Kanji Transmission Kanji Transmission is supported by the scanner when either Bluetooth HID or USB HID via 3610 is selected for the output interface. By Kanji Transmission, when the host computer is running on Japanese Windows O.S., the scanner is able to transmit Japanese characters including the Chinese characters used in modern Japanese writing system. Kanji Transmission is disabled by default. Enable/disable scanners Kanji Transmission by reading the following barcodes:
Enable
*Disable Enter Setup Chapter 2 Selecting Output Interface By default, Alternate key composing is disabled. Select [Yes] to allow emulating Alternate key code of a specific keyboard character. For example, [Alt] + [065] will be sent to host for the character A regardless the keyboard type you are using. ALT Composing Yes
*No 2.1.4 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254 in units of milliseconds, to match the computer response time of the keyboard interface. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Character Delay (*0~254) 1) Read the barcode above to specify the inter-character delay. 2) Read the Decimal Value barcode on page 271 for the desired inter-character delay
(in milliseconds). 3) Read the Validate barcode on the same page to complete this setting. 67 Update 1662/1664 Barcode Scanner User Guide 2.1.5 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of milliseconds, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Function Delay (*0~254) 1) Read the barcode above to specify the inter-function delay. 2) Read the Decimal Value barcode on page 271 for the desired inter-function delay (in milliseconds). 3) Read the Validate barcode on the same page to complete this setting. 68 Enter Setup Chapter 2 Selecting Output Interface 2.1.6 HID CHARACTER TRANSMIT MODE By default, HID interface sends data to the host character by character. You may have the scanner read the Batch Processing barcode to process data in batch. Batch Processing
*By Character Note: By Character transmit mode is required when working with iPhone or iPad. Its recommended that the Auto-Correction function on your iOS keyboard should be turned off. 2.1.7 SPECIAL KEYBOARD FEATURE By default, this interface doesnt employ special function codes (0x01 ~ 0x1F) defined in the Keyboard Wedge Table for users may want to get rid of these special codes within the barcodes to avoid data error. Or you can enable the Bypass with Control Character Output for Windows function to output control characters ranging from 0x01 to 0x1F in text form. For instance, [BS] (the backspace) is output rather than 0x08 when this function is enabled. You can decide whether to apply the special keyboard feature. For further details please refer to Keyboard Wedge Table.
*Bypass Apply Bypass with Control Character Output f or Windows Update 69 1662/1664 Barcode Scanner User Guide 2.1.8 KEYPAD SUPPORT FOR IPHONE/IPAD When the scanner has been successfully connected to iPhone or iPad for data collection, the onscreen keypad of iPhone or iPad will disappear. Read the Use POWER Key to Show or Hide Keypad barcode in advance. Then, it will allow pressing the [Power/Delete] key to show or hide the onscreen keypad. In addition to using the [Power/Delete] key, you may also show or hide the keypad by reading the following barcode. Note: This function only works for
(1) iPhone 4 and 3GS version 4.1 or later, and (2) iPad version 4.2 or later. 2.1.9 HID KEYBOARD LAYOUT (APPLE & NON-APPLE SYSTEM) By default, the scanner uses non-Apple keyboard layout. Read the following barcodes to toggle between Apple and non-Apple keyboard layouts.
*Normal Use POWER Key to Show or Hide Keypad Show or Hide Keypad Toggle to Apple Keyboard Layout
*Non-Apple Keyboard Layout 70 Enter Setup Chapter 2 Selecting Output Interface 2.1.10 TRANSMIT SPEED By default, the BT HID transmit speed is set to fast to have the scanner work in quicker transmit speed. 2.1.11 BT HID SLAVE/MASTER SWITCHING By default, the BT HID role is set to master. Users can have the scanner switch between slave and master by reading the barcodes below. 2.1.12 BT HID AUTO-RECONNECTION Users can decide whether to have the scanner automatically reconnect to a paired device after disconnection, and the occasion for reconnecting. Normal
*Fast Slave
*Master
*Auto reconnect immediately Auto reconnect on data being scanned Auto reconnect off Update 71 1662/1664 Barcode Scanner User Guide 2.2 BLUETOOTH SPP SLAVE 2.2.1 ACTIVATE BLUETOOTH SPP SLAVE MODE This is SPP Slave Mode. For Bluetooth SPP Slave, refer to Chapter 3 Setting up a WPAN Connection for related connection settings. 2.2.2 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of milliseconds, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Activate Bluetooth SPP, Slave Mode Inter-Function Delay (*0~254) 1) Read the barcode above to specify the inter-function delay. 2) Read the Decimal Value barcode on page 271 for the desired inter-function delay (in milliseconds). 3) Read the Validate barcode on the same page to complete this setting. 72 Enter Setup Chapter 2 Selecting Output Interface 2.2.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all attempts fail without any notification, data loss will occur. ACK/NAK Time-out after (*0~99) 1) Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host. 2) Read the Decimal Value barcode on page 271. For example, read 1 and 0 for the scanner to automatically shut down after being idle for 1 second. 3) Read the Validate barcode on the same page to complete this setting. ACK/NAK Error Beep Enable Error Beep
*Disable Error Beep Note: We suggest enabling the error beep so that you will be notified of such data loss and have the scanner re-read data. 73 Update 1662/1664 Barcode Scanner User Guide 2.3 BLUETOOTH SPP MASTER As a SPP master device, the scanner will be able to resume connection with the host upon powering on again, as long as the host application is running. If the scanner fails to resume connection, it will try every 5 seconds to re-connect to the host unless you read the Reset Connection or Restore System Defaults barcode. For Bluetooth SPP Master, refer 3.2.2 Configure Related Settings for related connection settings. Note: In SPP Master Mode, scanner has to connect to the host within the specified period of time (2 minutes by default). During the connection, the scanner will enter into idle mode to save power. It will automatically turn off when the time is up. Refer to 1.1.3 Auto Power Off & Power-Saving. 2.3.1 ACTIVATE BLUETOOTH SPP MASTER MODE This is SPP Master Mode. Activate Bluetooth SPP, Master Mode Connect with the target device by scanning two setting barcodes in sequence Produce two setup barcodes for the target SPP slave device, just like what we do for 3610. Set Connection MAC ID Note: The MAC ID barcode must have a prefix of two characters, either 0x or 0X, followed by the real MAC address of the target device. 1) Read the Activate Bluetooth SPP, Master Mode barcode above and barcodes for connection settings, such as authentication and preset PIN. Skip this step if no connection settings are desired. 2) Read the Set Connection and MAC ID barcodes. The scanner will respond with one beep upon reading each of the barcodes. Set Connection Usage:
74 Prefix 0X to target MAC address Enter Setup Chapter 2 Selecting Output Interface Note: Read the Set Connection barcode first, and then the MAC ID barcode within 10 seconds. Instead of producing the MAC ID barcode, you may read the setup barcodes for entering the MAC address. Read the Abort barcode to cancel the operation at any time while reading setup barcodes for the MAC address. If the MAC address has not been completed yet, reading the Validate barcode can cancel the operation as well. Enter MAC ID in Hexadecimal Usage:
1) 2) 3) Usage:
Read the barcode above. Read the Hexadecimal Value barcode on page 272 for the desired MAC address. Read the Validate barcode on the same page to complete this setting. Connect with the target device by scanning a single 1D setting barcode Users can produce a single 1D setup barcode that combines the Set Connection and MAC ID setup barcodes to connect with the target device. While producing the barcode, be aware the letter upper/lower case SeTcOn and the barcode must be the Code 128 symbology. 1) Read the Activate Bluetooth SPP, Master Mode barcode above and barcodes for connection settings, such as authentication and preset PIN. Skip this step if no connection settings are desired. 2) Read the SeTcOnxxxxxxxxxxxx 1D single barcode below. The scanner will respond with one beep upon reading the barcode. Connect with the target device by scanning a QR Code Users can also scan a QR Code that combines the Set Connection and MAC ID setup barcodes to connect with the target device. The example below is a 2D barcode containing codes #@CipherLab, 88686471166254 (Set Connection), 0x (Prefix to the target MAC ID), and 00D0176F0030 (MAC ID of the target device). Underlining the digits is to make them more readable.
#@CipherLab886864711662540X00D0176F0030 Command Purpose
#@CipherLab Enter Setup 88686471166254 Set connection 0X Prefix to the target MAC ID 00d0176f0030 MAC address ID of the target device 75 Update 1662/1664 Barcode Scanner User Guide The concatenation of setup barcodes can be combined to create a single 2D barcode as below:
Setup QR Code for connecting with a target device Exit SPP Master Mode To stop such re-connection, read Reset Connection or Restore System Defaults barcode so that the current connection record (= MAC ID) will be cleared. Then, the scanner will restart itself automatically. Go through the process in 3.2.3 Connect to Dongle to establish a new WPAN connection. Reset Connection 2.3.2 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of milliseconds, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Function Delay (*0~254) 1) Read the barcode above to specify the inter-function delay. 2) Read the Decimal Value barcode on page 271 for the desired inter-function delay (in milliseconds). 3) Read the Validate barcode on the same page to complete this setting. 76 Enter Setup Chapter 2 Selecting Output Interface 2.3.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all attempts fail without any notification, data loss will occur. ACK/NAK Time-out after (*0~99) 1) Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host. 2) Read the Decimal Value barcode on page 271. For example, read 1 and 0 for the scanner to automatically shut down after being idle for 1 second. 3) Read the Validate barcode on the same page to complete this setting. ACK/NAK Error Beep Enable Error Beep
*Disable Error Beep Note: We suggest enabling the error beep so that you will be notified of such data loss and have the scanner re-read data. 2.3.4 SWITCH BETWEEN MASTER/SLAVE MODE After the scanner has established a connection as a SPP slave device, you may read the Activate Bluetooth SPP, Master Mode setup barcode to switch to SPP Master Mode. This will result in easy and reliable re-connection, just like connecting with 3610. 77 Update 1662/1664 Barcode Scanner User Guide 2.3.5 BT SPP MASTER HARDWARE FLOW CONTROL By default, the data sending via Bluetooth SPP doesnt employ hardware flow control. In some cases users may want to enable hardware flow control to prevent data loss during transmission. Please scan the barcode below to enable/disable it. 2.3.6 BT SPP MASTER AUTO-RECONNECTION Users can decide whether to have the scanner automatically reconnect to a paired device after disconnection, and the occasion for reconnecting. Enable
*Disable
*Auto reconnect immediately Auto reconnect on data being scanned Auto reconnect off 78 Enter Setup Chapter 2 Selecting Output Interface 2.4 USB HID VIA 3610 For USB HID, connect 3610 to the USB port of PC, and then connect the scanner to 3610. The scanned data will be transmitted to the computer. To capture the data run any text editor on your computer. HID Settings Keyboard Type Alphabet Layout Numeric Layout Capital Lock Type Capital Lock State Alphabet Transmission Numeric Transmission Kanji Transmission Inter-Character Delay Inter-Function Delay Defaults PCAT (US) Normal Normal Normal Off Disable 0 (ms) 0 (ms) Case-sensitive Alphanumeric keypad 79 Update 1662/1664 Barcode Scanner User Guide 2.4.1 ACTIVATE USB HID & SELECT KEYBOARD TYPE When USB HID interface is activated, you will have to select a keyboard type to complete this setting. Activate 3610 USB HID & Select Keyboard Type 1) Read the barcode above to activate USB HID and select a keyboard type. 2) Read the Decimal Value barcode on page 271. Refer to the table below for the number of desired keyboard type. 3) Read the Validate barcode on the same page to complete this setting. Note: If this interface is not activated, you can also simply have the scanner read the one-scan setting barcode to activate BT HID and select keyboard type. Please refer to Appendix VI - Remote USB HID (via 3610). By default, the keyboard type is set to PCAT (US). The following keyboard types are supported USB HID No. Keyboard Type 64 PCAT (US) 65 PCAT (French) 66 PCAT (German) 67 PCAT (Italian) 68 PCAT (Swedish) No. Keyboard Type 72 PCAT (Spanish) 73 PCAT (Portuguese) 74 PS55 A01-2 (Japanese) 75 User-defined table 76 PCAT (Turkish) 69 PCAT (Norwegian) 77 PCAT (Hungarian) 70 PCAT (UK) 78 PCAT (Swiss German) 71 PCAT (Belgium) 79 PCAT (Danish) 80 Enter Setup Chapter 2 Selecting Output Interface 2.4.2 KEYBOARD SETTINGS Alphabet Layout Numeric Layout Capital Lock Type Capital Lock Setting Alphabet Transmission Numeric Transmission Kanji Transmission Alphabet Layout By default, the alphabet layout is set to normal mode, also known as the standard English layout. Select French or German keyboard layout if necessary. The scanner will make adjustments when sending the "A", "Q", "W", "Z", "Y", and "M" characters according to this setting. Note: This setting only works when the keyboard type selected is US keyboard, such as PCAT (US). The Alphabet Layout and Numeric Layout setting must match your keyboard.
*Normal AZERTY QWERTZ Update 81 1662/1664 Barcode Scanner User Guide US Keyboard Style Normal QWERTY layout, which is normally used in western countries. Select Lower Row for the Numeric Layout setting because the upper row is for special characters. French Keyboard Style AZERTY French layout; see below for French Keyboard Style. Select Upper Row for the Numeric Layout setting because the lower row is for special characters. German Keyboard Layout QWERTZ German layout; see below for German Keyboard Style. Select Lower Row for the Numeric Layout setting because the upper row is for special characters. 82 Enter Setup Chapter 2 Selecting Output Interface Select a proper layout that matches the alphabet layout. The scanner will make adjustments according to this setting. Numeric Layout Options Normal Lower Row Upper Row Description Depends on the [Shift] key or [Shift Lock] setting For QWERTY or QWERTZ keyboard For AZERTY keyboard
*Normal Upper Row Lower Row
*Normal Shift Lock Update Note: This setting is to be used with the Character Substitution setting when support for certain keyboard types (languages) is unavailable but required. In order to send the alphabet with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabet being transmitted. Capital Lock Type & Setting Cap Lock Type Description Normal Normal type Capital Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys. Shift Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. In addition, this affects the number or punctuation keys. 83 1662/1664 Barcode Scanner User Guide Capital Lock Capital Lock State Description Capital Lock OFF Capital Lock ON Assuming that the status of Caps Lock on the keyboard is OFF, transmitted characters are exactly the same as in the barcode (when
"case-sensitive" is selected for Alphabet Transmission). Assuming that the status of Caps Lock on the keyboard is ON, transmitted characters are exactly the same as in the barcode (when "case-sensitive"
is selected for Alphabet Transmission). Refer to the Capital Lock Type above. Auto Detection
(suggested use most applications) for The scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted; transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabet Transmission). Auto Detect Capital Lock ON
*Capital Lock OFF 84 Enter Setup Chapter 2 Selecting Output Interface Alphabet Transmission By default, the alphabet transmission is case-sensitive, meaning that the alphabet will be transmitted according to the original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabet transmitted according to the status of Caps Lock on the keyboard only. Ignore Case
*Case-sensitive Refer to 5.1 Letter Case. 85 Update 86 1662/1664 Barcode Scanner User Guide Numeric Transmission By default, the alphanumeric keypad is used for transmitting digits. Select Numeric Keypad if you wish to use the keys on the numeric keypad. Numeric Key
*Alphanumeric Key Note: If you select Numeric Keypad, the Num Lock status of the physical keyboard should be "ON". Kanji Transmission Kanji Transmission is supported by the scanner when either Bluetooth HID or USB HID via 3610 is selected for the output interface. By Kanji Transmission, when the host computer is running on Japanese Windows O.S., the scanner is able to transmit Japanese characters including the Chinese characters used in modern Japanese writing system. Kanji Transmission is disabled by default. Enable/disable scanners Kanji Transmission by reading the following barcodes:
Enable
*Disable Enter Setup Chapter 2 Selecting Output Interface 2.4.3 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254 in units of milliseconds, to match the computer response time of the keyboard interface. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Character Delay (*0~254) 1) Read the barcode above to specify the inter-character delay. 2) Read the Decimal Value barcode on page 271 for the desired inter-character delay
(in milliseconds). 3) Read the Validate barcode on the same page to complete this setting. 2.4.4 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of milliseconds, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Function Delay (*0~254) 1) Read the barcode above to specify the inter-function delay. 2) Read the Decimal Value barcode on page 271 for the desired inter-function delay (in milliseconds). 3) Read the Validate barcode on the same page to complete this setting. 87 Update 1662/1664 Barcode Scanner User Guide 2.4.5 HID CHARACTER TRANSMIT MODE By default, HID interface sends data to the host character by character. You may have the scanner read the Batch Processing barcode to process data in batch. 2.4.6 SPECIAL KEYBOARD FEATURE By default, the special keyboard feature is based on the factory definition. You can decide whether to apply the special keyboard feature. Refer to Keyboard Wedge Table. 2.4.7 USB HID VIA 3610 AUTO-RECONNECTION Users can decide whether to have the scanner automatically reconnect to a paired device after disconnection, and the occasion for reconnecting. Batch Processing
*By Character
*Apply Bypass
*Auto reconnect immediately Auto reconnect on data being scanned Auto reconnect off 88 Enter Setup Chapter 2 Selecting Output Interface 2.5 USB VIRTUAL COM VIA 3610 Connect 3610 to the USB port of PC, and then connect the scanner to 3610. You may run HyperTerminal.exe on the computer to view and capture the data transmission from the scanner. 2.5.1 ACTIVATE USB VIRTUAL COM Note: If using USB Virtual COM for the first time, you must install its driver beforehand. Driver version 5.4 or later is required. Please remove older versions before installing new ones!
2.5.2 ACTIVATE USB VIRTUAL COM_CDC Note: 3610 with firmware version 2.0 or later supports this function. 2.5.3 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of milliseconds, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. 1) Read the barcode above to specify the inter-function delay. 2) Read the Decimal Value barcode on page 271 for the desired inter-function delay (in milliseconds). 3) Read the Validate barcode on the same page to complete this setting. Activate 3610 USB Virtual COM Activate 3610 USB Virtual COM_CDC Inter-Function Delay (*0~254) Update 89 1662/1664 Barcode Scanner User Guide 2.5.4 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all attempts fail without any notification, data loss will occur. 1) Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host. 2) Read the Decimal Value barcode on page 271. For example, read 1 and 0 for the scanner to automatically shut down after being idle for 1 second. 3) Read the Validate barcode on the same page to complete this setting. ACK/NAK Time-out after (*0~99) Enable Error Beep
*Disable Error Beep ACK/NAK Error Beep Note: We suggest enabling the error beep so that you will be notified of such data loss and have the scanner re-read data. 90 Enter Setup Chapter 2 Selecting Output Interface 2.5.5 USB VCOM VIA 3610 AUTO-RECONNECTION Users can decide whether to have the scanner automatically reconnect to a paired device after disconnection, and the occasion for reconnecting.
*Auto reconnect immediately Auto reconnect on data being scanned Auto reconnect off Update 91 1662/1664 Barcode Scanner User Guide 2.6 DIRECT USB HID 1662/1664 supports Direct USB HID interface for memory mode. Use the provided USB cable to connect 1662/1664 to the USB port of PC. Run any text editor on a computer to view and capture the scanned data being transmitted to the computer. Refer to 1.2.2 Memory Mode. HID Settings Keyboard Type Numeric Layout Capital Lock Type Capital Lock State Alphabet Transmission Numeric Transmission Kanji Transmission Alphabet Layout Inter-Character Delay Inter-Function Delay HID PCAT (US) Defaults Normal Normal OFF Disable Normal 0 (ms) 0 (ms) Case Sensitive Alphanumeric Keypad 92 Enter Setup Chapter 2 Selecting Output Interface 2.6.1 ACTIVATE USB HID & SELECT KEYBOARD TYPE When USB HID interface is activated, please select a keyboard type to complete this setting. Activate Direct USB HID &
Select Keyboard Type 1) Read the barcode above to activate USB HID and select a keyboard type. 2) Read the Decimal Value barcode page 271 . Refer to the table below for the number of desired keyboard type. 3) Read the Validate barcode on the same page to complete this setting. USB HID By default, the keyboard type is set to PCAT (US). The following keyboard types are supported for PC No. Keyboard Type (PCAT) No. Keyboard Type (PCAT) 64 PCAT (US) 65 PCAT (French) 66 PCAT (German) 67 PCAT (Italian) 68 PCAT (Swedish) 70 PCAT (UK) 71 PCAT (Belgium) 72 PCAT (Spanish) 73 PCAT (Portuguese) 74 PS55 A01-2 (Japanese) 75 User-defined table 76 PCAT (Turkish) 77 PCAT (Hungarian) 79 PCAT (Danish) 80 PCAT (Dutch) 87 PCAT (Brazilian Portuguese) 69 PCAT (Norwegian) 78 PCAT (Swiss German) 93 Update 1662/1664 Barcode Scanner User Guide The following keyboard types are supported for Apple No. Keyboard Type (Apple) No. Keyboard Type (Apple) 64 Apple (US) 65 Apple (French) 66 Apple (German) 67 Apple (Italian) 68 Apple (Swedish) 69 Apple (Norwegian) 72 Apple (Spanish) 78 Apple (Swiss German) 79 Apple (Danish) 80 Apple (Dutch) 81 Apple (Greek) 82 Apple (Hebrew) 83 Apple (Russian) 84 Apple (Flemish) 73 Apple (Portuguese) 85 Apple (Arabic) 75 User-defined table 86 Apple (Austria German) 76 Apple (Turkish) 87 Apple (Brazilian Portuguese) Note: 81/82/83/85 keyboard types dont support English input. 94 Enter Setup Chapter 2 Selecting Output Interface 2.6.2 KEYBOARD SETTINGS Alphabet Layout Numeric Layout Capital Lock Type Capital Lock Setting Alphabet Transmission Numeric Transmission Kanji Transmission Alphabet Layout By default, the alphabet layout is set to normal mode, also known as the standard English layout. Select French or German keyboard layout if necessary. The scanner will make adjustments when sending the "A", "Q", "W", "Z", "Y", and "M" characters according to this setting. Note: This setting only works when the keyboard type selected is US keyboard, such as PCAT (US). The Alphabet Layout and Numeric Layout setting must match using keyboard.
*Normal AZERTY QWERTZ Update 95 1662/1664 Barcode Scanner User Guide US Keyboard Style Normal QWERTY layout, which is normally used in western countries. Select Lower Row for the Numeric Layout setting because the upper row is for special characters. French Keyboard Style AZERTY French layout; see below for French Keyboard Style. Select Upper Row for the Numeric Layout setting because the lower row is for special characters. German Keyboard Layout QWERTZ German layout; see below for German Keyboard Style. Select Lower Row for the Numeric Layout setting because the upper row is for special characters. 96 Enter Setup Chapter 2 Selecting Output Interface Select a proper layout that matches the alphabet layout. The scanner will make adjustments according to this setting. Numeric Layout Options Normal Lower Row Upper Row Description Depends on the [Shift] key or [Shift Lock] setting For QWERTY or QWERTZ keyboard For AZERTY keyboard Note: This setting is to be used with the Character Substitution setting when support for certain keyboard types (languages) is unavailable but required. In order to send the alphabet with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabet being transmitted. Capital Lock Type & Setting Cap Lock Type Description Normal Normal type Capital Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys. Shift Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. In addition, this affects the number or punctuation keys.
*Normal Upper Row Lower Row
*Normal Shift Lock Update 97 1662/1664 Barcode Scanner User Guide Capital Lock Capital Lock State Description Capital Lock OFF Capital Lock ON Assuming that the status of Caps Lock on the keyboard is OFF, transmitted characters are exactly the same as in the barcode (when
"case-sensitive" is selected for Alphabet Transmission). Assuming that the status of Caps Lock on the keyboard is ON, transmitted characters are exactly the same as in the barcode (when "case-sensitive"
is selected for Alphabet Transmission). Refer to the Capital Lock Type above. Auto Detection
(suggested use most applications) for The scanner will automatically detect the status of Caps Lock on the keyboard before data is transmitted; transmitted characters are exactly the same as in the barcode (when "case-sensitive" is selected for Alphabet Transmission). Auto Detect Capital Lock ON
*Capital Lock OFF 98 Enter Setup Chapter 2 Selecting Output Interface Alphabet Transmission By default, the alphabet transmission is case-sensitive, meaning that the alphabet will be transmitted according to the original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabet transmitted according to the status of Caps Lock on the keyboard only. Ignore Case
*Case-sensitive Refer to 5.1 Letter Case. 99 Update 100 1662/1664 Barcode Scanner User Guide Numeric Transmission By default, the alphanumeric keypad is used for transmitting numerics. Select Numeric Keypad if want to use the keys on the numeric keypad. Numeric Key
*Alphanumeric Key Note: If selecting Numeric Keypad, the Num Lock status of the physical keyboard should be "ON". Kanji Transmission Kanji Transmission is supported by the scanner when either Bluetooth HID or USB HID is selected for the output interface. By Kanji Transmission, when the host computer is running on Japanese Windows O.S., the scanner is able to transmit Japanese characters including the Chinese characters used in modern Japanese writing system. Kanji Transmission is disabled by default. Enable/disable scanners Kanji Transmission by reading the following barcodes:
Enable
*Disable Enter Setup Chapter 2 Selecting Output Interface 2.6.3 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254 in units of milliseconds, to match the computer response time of the keyboard interface. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Character Delay (*0~254) 1) Read the barcode above to specify the inter-character delay. 2) Read the Decimal Value barcode on page 271 for the desired inter-character delay
(in milliseconds). 3) Read the Validate barcode on the same page to complete this setting. 2.6.4 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of milliseconds, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Function Delay (*0~254) 1) Read the barcode above to specify the inter-function delay. 2) Read the Decimal Value barcode on page 271 for the desired inter-function delay (in milliseconds). 3) Read the Validate barcode on the same page to complete this setting. 101 Update 1662/1664 Barcode Scanner User Guide 2.6.5 HID CHARACTER TRANSMIT MODE By default, HID interface sends data to the host character by character. You may have the scanner read the Batch Processing barcode to process data in batch. 2.6.6 SPECIAL KEYBOARD FEATURE By default, the special keyboard feature is based on the factory definition. You can decide whether to apply the special keyboard feature. Refer to Keyboard Wedge Table. Batch Processing
*By Character
*Apply Bypass Set USB polling interval 1~15 ms
(*4) 2.6.7 USB POLLING INTERVAL Scan the barcodes below to specify the USB polling interval ranging from 1 to 15ms. Its set to 10ms by default. 1) Read the barcode above to specify the USB polling interval. 2) Read the Decimal Value barcode on page 271 for the desired time period (in milliseconds). 3) Read the Validate barcode on the same page to complete this setting. 102 Enter Setup Chapter 2 Selecting Output Interface 2.7 DIRECT USB VIRTUAL COM 1662/1664 supports Direct USB Virtual COM interface for memory mode. Use the provided USB cable to connect 1662/1664 to the USB port of PC. You may run HyperTerminal.exe on a computer to view and capture the scanned data being transmitted to the computer. Refer to 1.2.2 Memory Mode. 2.7.1 ACTIVATE USB VIRTUAL COM Note: If using USB Virtual COM for the first time, you must install its driver beforehand. Driver version 5.4 or later is required. Please remove older versions before installing new ones!
2.7.2 ACTIVATE USB VIRTUAL COM_CDC
*Activate Direct USB Virtual COM
*Activate Direct USB Virtual COM_CDC Note: If using USB Virtual COM_CDC for the first time, you must install its driver beforehand. 2.7.3 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of milliseconds, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Function Delay (*0~254) 1) Read the barcode above to specify the inter-function delay. 2) Read the Decimal Value barcode on page 271 for the desired inter-function delay (in milliseconds). 3) Read the Validate barcode on the same page to complete this setting. 103 Update 1662/1664 Barcode Scanner User Guide 2.7.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all attempts fail without any notification, data loss will occur. ACK/NAK Time-out after (*0~99) 1) Read the barcode above to specify the time interval for the scanner to send data and wait for a response from the host. 2) Read the Decimal Value barcode on page 271. For example, read 1 and 0 for the scanner to automatically shut down after being idle for 1 second. 3) Read the Validate barcode on the same page to complete this setting. ACK/NAK Error Beep Enable Error Beep
*Disable Error Beep Note: We suggest enabling the error beep so that data loss is notified and the scanner re-read data. 104 Enter Setup Chapter 2 Selecting Output Interface 105 Update SET UP A WPAN CONNECTION The scanner can be configured to send data to a host computer wirelessly via the 3610 dongle, or to a notebook computer or PDA with Bluetooth wireless technology. Upon powering up, the scanner will be ready to establish a WPAN connection. To establish a connection via 3610 after reading Set Connection and Serial No. labels Chapter 3 Interface Option USB HID USB Virtual COM Reference 2.4 USB HID via 3610 2.5 USB Virtual COM via 3610 To establish a connection via Bluetooth dongle after pairing Interface Option Bluetooth HID Bluetooth SPP IN THIS CHAPTER Reference 2.1 Bluetooth HID 2.2 Bluetooth SPP Slave, 2.3 Bluetooth SPP Master 3.1 Connecting via 3610 .................................................. 107 3.2 Connecting via Bluetooth Dongle ............................... 110 Update 106 Chapter 3 Set up a WPAN Connection 3.1 CONNECTING VIA 3610 USB HID and USB Virtual COM are alternative interfaces between 3610 and the host it connects. By default, the interface of 3610 is set to USB HID. You can have up to seven scanners connected to one computer at the same time. Note: If using USB Virtual COM for the first time, you must install its driver beforehand. Driver version 5.4 or later is required. Please remove older versions!
3.1.1 CONNECT TO 3610 By scanning two setting barcodes in sequence Connect any scanner to 3610 by reading the two labels at the back of 3610. The scanner will respond with one beep upon reading each of the labels. Set Connection label Serial Number label After reading these labels, the scanner will stay active for a specified period of time (2 minutes by default) trying to connect to the 3610 while its LED is flashing blue (On/Off ratio 0.5 s: 0.5 s). Once connected, the scanner will respond with three beeps (tone ascending from low to high), and the LED flashes blue (On/Off ratio 0.02 s: 3 s). When out of range, the scanner will respond with three short beeps (tone descending from high to low). Read the Set Connection barcode first, and then the Serial Number barcode. If the Set Connection barcode on 3610 is illegible, try this one Usage:
Set Connection Note: The 3610 settings will overwrite the interface-related settings on the scanners that are currently connected to 3610. By scanning a single 1D setting barcode Users can produce a single 1D setup barcode that combines the Set Connection and 3610 Serial Number setup commands to connect with 3610. While producing the barcode, be aware the letter upper/lower case SeTcOn and the barcode must be the Code 128 symbology. Read the SeTcOnxxxxxxxxx single 1D barcode (xxxxxxxxx represents the 3610 serial number). The scanner will respond with one beep upon reading the barcode. Usage:
By scanning a QR Code Users can also scan a QR Code that combines the Set Connection and Serial Number setup barcodes to connect to 3610. The example below is a QR Code containing codes #@CipherLab, 88686471166254 (Set Connection) and BS6065535 (Serial Number of 3610). Underlining the digits 107 Update 1662/1664 Barcode Scanner User Guide is to make them more readable.
#@CipherLab88686471166254BS6065535 Command Purpose
#@CipherLab Enter setup 88686471166254 Set connection BS6065535 Serial number of 3610 Setup QR Code for connecting to 3610 The concatenation of setup barcodes can be combined to create a single 2D barcode as below:
108 Enter Setup Chapter 3 Set up a WPAN Connection 3.1.2 CHANGE INTERFACE If you want to change the interface of 3610, use one of the connected scanners to configure the interface-related settings and it will pass the new settings to 3610, which will then initialize and pass the settings to any other connected scanners. 1) Read the Set Connection and Serial Number labels at the back of 3610. 2) Within two minutes, connect 3610 to the USB port of PC. For USB Virtual COM, you will need to install its driver first!
3) The scanners will connect to the computer via 3610. 4) Read the Enter Setup barcode to enter the configuration mode. 5) Read the desired interface barcode and configure its related settings Activate USB HID & Select Keyboard Type Activate USB Virtual COM 6) Read the Update barcode to exit the configuration mode. 7) After the scanner resumes connection with 3610, it will pass the interface-related settings to 3610. 8) Upon receipt of the new settings, 3610 will initialize itself. 9) Updated with new settings, 3610 will pass the settings to other connected scanners. 109 Update 1662/1664 Barcode Scanner User Guide 3.1.3 CONFIGURE RELATED SETTINGS Sniff Mode (Power-saving) By default, this feature is enabled, meaning the scanner will listen to the wireless network at a reduced rate.
*Enable Disable 3.2 CONNECTING VIA BLUETOOTH DONGLE 3.2.1 CHANGE INTERFACE Below is the procedure to configure the scanner before establishing a WPAN connection via Bluetooth dongle. 1) Read the Enter Setup barcode to enter the configuration mode. 2) Read the desired interface barcode Activate Bluetooth HID & Select Keyboard Type Activate Bluetooth SPP Slave Mode Activate Bluetooth SPP Master Mode 3) Read the barcodes related to WPAN settings, such as Device Name Broadcasting, Authentication & PIN Code, etc. 4) Read the Update barcode to exit the configuration mode. 5) The scanner will stay active for a specified period of time (2 minutes by default) waiting for a connection request from the host (SPP Slave Mode) or trying to connect to the host (HID or SPP Master Mode). Its CPU is running at full speed, and the LED is flashing blue (On/Off ratio 0.5 s: 0.5 s). Once connected, when out of range, the scanner will respond with three short beeps
(tone descending from high to low). 110 Enter Setup Chapter 3 Set up a WPAN Connection 3.2.2 CONFIGURE RELATED SETTINGS Sniff Mode (Power-saving) By default, this feature is enabled, meaning the scanner will listen to the wireless network at a reduced rate.
*Enable Disable
*Enable Disable Note: When connecting more than two scanners to a notebook computer or PDA with Bluetooth wireless technology, we suggest that you disable the power-saving setting for a more reliable connection. Device Name Broadcasting The scanner can be configured to hide itself from other devices equipped with Bluetooth wireless technology. Simply disable the device name broadcasting setting so that it wont be discovered by any other computer or PDA. However, broadcasting must be enabled for establishing an initial connection with the scanner. For example, disable device name broadcasting after successfully connecting the scanner to WorkStation1. Such connection will be maintained automatically unless the scanner is removed from the paired device list (called unpairing) by WorkStation1 or any changes made to authentication and the PIN code. If you want WorkStation2 to connect to the scanner, you have to enable device name broadcasting first. Note: By default, device name broadcasting is enabled (which is required for initial connection). Changing Device Name By default, the device name (local hostname) combines the model name with serial number (for example, 1664AS2000001). Users are allowed to configure the device name with length up to 13 bytes. 111 Update 1662/1664 Barcode Scanner User Guide Change Bluetooth Local Hostname 1) Read the barcode above to configure the device name. 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. 3) Read the Validate barcode to complete this setting. 112 Enter Setup Chapter 3 Set up a WPAN Connection Authentication When any changes are made to authentication and PIN code on the scanner side, you will have to remove the scanner from the paired device list (called unpairing) and go through the whole process to re-establish the connection. The scanner allows up to 16 characters for a PIN code and provides two options for authentication:
Enable Authentication with Preset PIN Read the Use preset PIN barcode, and change the preset PIN if necessary. This means you will have to enter exactly the same string for your computer or PDA to connect to the scanner. If the PIN or passkey is incorrect, any connection attempt will be turned down by the scanner. See step 8 in 3.2.3 Connect to Dongle. 1) Read the Use preset PIN barcode to enable authentication with a preset PIN. Use Preset PIN 2) Read one of the barcodes to specify the PIN code, in decimal or hexadecimal. By default, the PIN code is set to 0000. Maximum 16 characters are allowed. 3) Read the Decimal Value barcode on page 271 or the Hexadecimal Value barcode on page 272 for the desired digits or character string. Read the Clear PIN Code barcode first if you need to re-input the PIN code. 4) Read the Validate barcode to complete this setting. Enable Authentication with Random PIN or No Authentication By default, it is set to No PIN or use random PIN, which depends on the setting of the target device. (No PIN = No authentication.) Enter PIN in Hexadecimal Enter PIN in Decimal Clear PIN Code
*No PIN or use random PIN Update 113 1662/1664 Barcode Scanner User Guide Use random PIN No PIN required Note: When using Bluetooth HID, some device driver may not support pre-defined PIN code for authentication. In this case, make sure you have the scanner set to No PIN or use random PIN before pairing. While pairing, the host PIN code will be displayed on the computer screen. Have the scanner read the setup barcode Enter PIN Code in Decimal or Enter PIN Code in Hexadecimal to input the matching PIN code. Refer to Disable Authentication or Use Random PIN. 114 Enter Setup Chapter 3 Set up a WPAN Connection 3.2.3 CONNECT TO DONGLE The procedure goes through associating devices for establishing a WPAN connection, which is pretty much the same except for the software you are using. If your computer is running Microsoft Windows XP (SP1 to SP3), Windows Vista Service Pack 1 (SP1) and Windows 7, you can use the software support that Windows includes, or you can use the driver that the device manufacturer provides. Now, lets try using the software support that Windows XP Service Pack 2 includes. Bluetooth HID Procedure By default, Bluetooth HID is activated on the scanner, and the keyboard type is set to PCAT (US). When Bluetooth HID is re-activated, you will have to select a keyboard type to complete this setting. The procedure is the same as for Bluetooth SPP. Refer to steps 1~11 below. Bluetooth SPP Procedure 1) 2) Turn on the Bluetooth function on your computer running Windows XP SP2. Double-click the Bluetooth icon from the lower right of the taskbar. Alternatively, you may go to Control Panel > Bluetooth Devices. 3) Click [Add] to search devices nearby. 115 Update 1662/1664 Barcode Scanner User Guide 4) 5) Click [Next]. Turn on the scanner with correct WPAN settings, such as select Bluetooth SPP or Bluetooth HID, broadcasting enabled, authentication enabled, and PIN code specified, etc. Select the check box of [My device is set up and ready to be found] on your computer. 6) Wait for a few seconds for the Wizard to search available devices nearby. The scanner will appear with its serial number as the device name. You may double-check the Serial Number label on the scanner to ensure connecting with the correct scanner. Select the target scanner. If the target scanner does not appear on the list, click [Search Again] to refresh the list. The scanner might enter Suspend Mode now, and you can press the trigger to have it active again (=discoverable). It will then stay active for a specified period of time (2 minutes by default) and wait for PC to establish a connection. 116 Enter Setup 7) Click [Next]. Chapter 3 Set up a WPAN Connection 8) Enter the passkey for authentication, which must be exactly the same as configured for the scanner. 117 Update 1662/1664 Barcode Scanner User Guide 9) Click [Next]. Wait for a few seconds for Windows to exchange passkeys. 118 Enter Setup Chapter 3 Set up a WPAN Connection Note: When Bluetooth security is enabled without providing a pre-set PIN code, dynamic input of PIN code is supported. 10) Click [Finish]. 1664 as Bluetooth SPP Slave 1664 as Bluetooth SPP Master 119 Update 1662/1664 Barcode Scanner User Guide 11) Now the target scanner will be listed as shown below. You can have up to seven scanners connected to one computer at the same time. 120 Select and Remove Note: When any changes are made to authentication and PIN code on the scanner side, or you want to change to use Bluetooth HID, it is suggested that you remove the scanner from the paired device list (called unpairing) and go through the whole process to re-establish the connection. 12) Run the desired application on your computer, such as HyperTerminal.exe if using Bluetooth SPP or Notepad.exe if using Bluetooth HID. The status of the scanner listed on the device list will be updated to Connected, indicating the WPAN connection is established successfully via the outgoing COM port if using Bluetooth SPP. Note: Even though the scanner is connected to the host with authentication disabled (=
no PIN code required), the host may still request a PIN code while the application is opening COM port. Dynamic input of PIN code is supported so that you may input a matching PIN code on the scanner. Refer to Disable Authentication or Use Random PIN. Enter Setup Chapter 3 Set up a WPAN Connection Bluetooth SPP Connected Bluetooth SPP Disconnected 121 Update 1662/1664 Barcode Scanner User Guide 3.2.4 SECURE SIMPLE PAIRING (SSP) Secure Simple Pairing (SSP), introduced in Bluetooth Core Specification 2.1 + EDR, is a new feature designed to ease the pairing process while keeping up the communication security level. When connecting to a Bluetooth host that supports Bluetooth HID or Bluetooth SPP profile, you can implement the secure simple pairing process. Enabled by default, the password dialog box wont show up during the pairing process. Disable
*Enable Note: Secure Simple Pairing only supports to devices with Bluetooth v2.1 or later. 122 Enter Setup Chapter 4 CHANGE SYMBOLOGY SETTINGS In this chapter, a brief on the symbology settings is provided for your reference. For users convenience, the two setting barcodes below allows disabling/enabling supported symbologies all at once. Enable All Symbologies Disable All Symbologies IN THIS CHAPTER 4.1 Codabar .................................................................. 124 4.2 Code 25 Industrial 25 ............................................. 126 4.3 Code 25 Interleaved 25 ........................................... 128 4.4 Code 25 Matrix 25 .................................................. 131 4.5 Code 25 Chinese 25 ................................................ 133 4.6 Italian Pharmacode (Code 32) .................................... 134 4.7 Code 39 .................................................................. 135 4.8 Trioptic Code 39 ....................................................... 138 4.9 Code 93 .................................................................. 139 4.10 Code 128 ............................................................... 141 4.11 GS1-128 (EAN-128) ................................................ 142 4.12 ISBT 128 ............................................................... 144 4.13 GS1 DataBar (RSS Family) ....................................... 146 4.14 MSI ....................................................................... 152 4.15 EAN-8 ................................................................... 154 4.16 EAN-13 .................................................................. 155 4.17 UCC Coupon Extended Code ..................................... 160 4.18 UPC-A ................................................................... 161 4.19 UPC-E ................................................................... 163 4.20 Code 11 ................................................................. 166 4.21 Composite Code ...................................................... 168 4.22 US Postal Code ....................................................... 172 4.23 UK Postal Code ....................................................... 173 4.24 More Postal Code .................................................... 174 4.25 2D Symbologies ...................................................... 176 4.26 Macro PDF .............................................................. 179 Update 123 124 1662/1664 Barcode Scanner User Guide 4.1 CODABAR 4.1.1 START/STOP TRANSMISSION Decide whether to include the start/stop characters in the data being transmitted.
*Enable Disable Transmit Start/Stop Characters
*Do Not Transmit Apply CLSI Editing
*Do Not Apply Enter Setup 4.1.2 CLSI CONVERSION When enabled, the CLSI editing strips the start/stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar barcode. Note: The 14-character barcode length does not include start/stop characters. Chapter 4 Change Symbology Settings 4.1.3 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If Fixed Length is selected, up to 2 fixed lengths can be specified. Note: The specified length(s) must include the check digit(s) the barcode contains. 1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification. 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2. 3) Read the Decimal Value barcode on page 271 for the desired length. 4) Read the Validate barcode on the same page to complete this setting. 125
*Enable Max./Min. Length (1~55) Enable Fixed Length(s) Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 Update 1662/1664 Barcode Scanner User Guide 4.2 CODE 25 INDUSTRIAL 25
*Enable Disable 126 Enter Setup Chapter 4 Change Symbology Settings 4.2.1 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If Fixed Length is selected, up to 2 fixed lengths can be specified. Note: The specified length(s) must include the check digit(s) the barcode contains. 1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification. 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2. 3) Read the Decimal Value barcode on page 271 for the desired length. 4) Read the Validate barcode on the same page to complete this setting. 127
*Enable Max./Min. Length (1~55) Enable Fixed Length(s) Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 Update 1662/1664 Barcode Scanner User Guide 4.3 CODE 25 INTERLEAVED 25 4.3.1 VERIFY CHECK DIGIT Decide whether to verify the check digit. When desired, select one of the algorithms, USS or OPCC. If incorrect, the barcode will not be accepted.
*Enable Disable
*Do Not Verify USS Check Digit OPCC Check Digit
*Transmit Interleaved 25 Check Digit Do Not Transmit 4.3.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. 128 Enter Setup Chapter 4 Change Symbology Settings 4.3.3 CONVERT TO EAN-13 Decide whether to convert a 14-character barcode into EAN-13 if the following requirements are met:
The barcode must have a leading 0 and a valid EAN-13 check digit. Verify Check Digit must be disabled. Convert to EAN-13
*Do Not Convert 129 Update 1662/1664 Barcode Scanner User Guide 4.3.4 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If Fixed Length is selected, up to 2 fixed lengths can be specified. Note: The specified length(s) must include the check digit(s) the barcode contains. 1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.
*Enable Max./Min. Length (1~55) Enable Fixed Length(s) Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2. 3) Read the Decimal Value barcode on page 271 for the desired length. 4) Read the Validate barcode on the same page to complete this setting. 130 Enter Setup 4.4 CODE 25 MATRIX 25 Chapter 4 Change Symbology Settings 4.4.1 VERIFY CHECK DIGIT Decide whether to verify the check digit. If incorrect, the barcode will not be accepted. Enable
*Disable Verify Matrix 25 Check Digit
*Do Not Verify
*Transmit Matrix 25 Check Digit Do Not Transmit 4.4.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. 131 Update 1662/1664 Barcode Scanner User Guide 4.4.3 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If Fixed Length is selected, up to 2 fixed lengths can be specified. Note: The specified length(s) must include the check digit(s) the barcode contains. 1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.
*Enable Max./Min. Length (1~55) Enable Fixed Length(s) Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2. 3) Read the Decimal Value barcode on page 271 for the desired length. 4) Read the Validate barcode on the same page to complete this setting. 132 Enter Setup 4.5 CODE 25 CHINESE 25 Chapter 4 Change Symbology Settings Enable
*Disable 133 Update 1662/1664 Barcode Scanner User Guide 4.6 ITALIAN PHARMACODE (CODE 32) Note: Code 39 must be enabled first. Enable
*Disable 134 Enter Setup 4.7 CODE 39 Chapter 4 Change Symbology Settings 4.7.1 VERIFY CHECK DIGIT Decide whether to verify the check digit. If incorrect, the barcode will not be accepted.
*Enable Disable Verify Code 39 Check Digit
*Do Not Verify
*Transmit Code 39 Check Digit Do Not Transmit 4.7.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. 135 Update 1662/1664 Barcode Scanner User Guide 4.7.3 STANDARD/FULL ASCII CODE 39 Decide whether to support Code 39 Full ASCII that includes all the alphanumeric and special characters. Code 39 Full ASCII
*Standard Code 39 Note: Trioptic Code 39 and Code 39 Full ASCII cannot be enabled at the same time. 136 Enter Setup Chapter 4 Change Symbology Settings 4.7.4 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If Fixed Length is selected, up to 2 fixed lengths can be specified. Note: The specified length(s) must include the check digit(s) the barcode contains. 1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification. 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2. 3) Read the Decimal Value barcode on page 271 for the desired length. 4) Read the Validate barcode on the same page to complete this setting.
*Enable Max./Min. Length (1~55) Enable Fixed Length(s) Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 Update 137 1662/1664 Barcode Scanner User Guide 4.8 TRIOPTIC CODE 39 Decide whether to decode Trioptic Code 39. Trioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges. It always contains six characters. Enable
*Disable Note: Trioptic Code 39 and Code 39 Full ASCII cannot be enabled at the same time. 138 Enter Setup 4.9 CODE 93 Chapter 4 Change Symbology Settings
*Enable Disable 139 Update 1662/1664 Barcode Scanner User Guide 4.9.1 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If Fixed Length is selected, up to 2 fixed lengths can be specified. Note: The specified length(s) must include the check digit(s) the barcode contains. 1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification.
*Enable Max./Min. Length (1~55) Enable Fixed Length(s) Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2. 3) Read the Decimal Value barcode on page 271 for the desired length. 4) Read the Validate barcode on the same page to complete this setting. 140 Enter Setup 4.10 CODE 128 Chapter 4 Change Symbology Settings
*Enable Disable 141 Update 1662/1664 Barcode Scanner User Guide 4.11 GS1-128 (EAN-128) 142 Note: GS1-128 barcodes can be decoded only when this setting is enabled. 4.11.1 TRANSMIT CODE ID Decide whether to include the Code ID (]C1) in the data being transmitted.
*Enable Disable Transmit GS1-128 Code ID
*Do Not Transmit Specify Field Separator 4.11.2 FIELD SEPARATOR (GS CHARACTER) Decide whether to apply a field separator (to convert the FNC1 control character to human readable character). 1) Read the barcode above to specify field separator. 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. 3) Read the Validate barcode to complete this setting. Note: GS1-128 barcodes start with the FNC1 control character to distinguish themselves from other uses of Code 128. FNC1 is also used to separate data fields in the GS1-
128 barcodes. Enter Setup Chapter 4 Change Symbology Settings 4.11.3 GS1 FORMATTING Decide whether to enable GS1 formatting for GS1-128. When enabled, code ID transmitting will be disabled; however, the field separator and application ID mark characters will be automatically added to the output data. You may want to add an application ID mark (1 character long) to the left (AIMark1) or right (AIMark2) of an application ID (AI) for the purpose of labeling it when formatting the GS1 data. 1) Read the barcode above to add a mark to the left (AIMark1)/right (AIMark2) of an application ID. 2) Read the Hexadecimal Value barcode on page 272 for the desired character. Read
'00' if you want to remove the AI mark. 3) Read the Validate barcode to complete this setting. Enable
*Disable AIMark1 AIMark2 143 Update 1662/1664 Barcode Scanner User Guide 4.12 ISBT 128
*Enable Disable 4.12.1 ISBT CONCATENATION (1664 ONLY) Decide whether to decode and concatenate pairs of ISBT barcodes. Disable ISBT Concatenation It will not concatenate pairs of ISBT barcodes it encounters. Only one single ISBT 128 barcode outputs. Enable ISBT Concatenation There must be two ISBT barcodes in order for the scanner to decode and perform concatenation. It does not decode single ISBT barcodes. Auto-discriminate ISBT Concatenation It decodes and concatenates pairs of ISBT barcodes immediately. If only a single ISBT barcode is present, the scanner must decode 10 times before transmitting its data to confirm that there is no additional ISBT barcode. Disable Enable
*Auto-discriminate 144 Enter Setup Chapter 4 Change Symbology Settings 4.12.2 ISBT CONCATENATION REDUNDANCY (1664 ONLY) Specify the concatenation redundancy (2~20 times) when ISBT concatenation is enabled. ISBT Concatenation Redundancy 2~20
(*10) 1) Read the barcode above to specify the concatenation redundancy. 2) Read the Decimal Value barcode on page 271 for the desired redundancy. 3) Read the Validate barcode on the same page to complete this setting. 145 Update 1662/1664 Barcode Scanner User Guide 4.13 GS1 DATABAR (RSS FAMILY) It is categorized into three groups:
Group I GS1 DataBar Omnidirectional (RSS-14) This group consists of the following:
GS1 DataBar Omnidirectional GS1 DataBar Truncated GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional GS1 DataBar Expanded GS1 DataBar Expanded Stacked Group II GS1 DataBar Expanded (RSS Expanded) This group consists of the following:
Group III GS1 DataBar Limited (RSS Limited) This group consists of the following:
GS1 DataBar Limited 4.13.1 SELECT CODE ID Select a desired Code ID to use:
]e0
]C1
(GS1 DataBar Code ID)
(GS1-128 Code ID) Use ]C1
*Use ]e0 146 Enter Setup 4.13.2 GS1 DATABAR OMNIDIRECTIONAL (RSS-14) Chapter 4 Change Symbology Settings When GS1 formatting for GS1 DataBar Omnidirectional is enabled, code ID transmitting will be disabled; however, application ID transmitting will be enabled automatically. The settings below apply to Group I symbologies only:
GS1 DataBar Omnidirectional GS1 DataBar Truncated GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional Transmit Code ID Decide whether to include the Code ID in the data being transmitted. Transmit Application ID Decide whether to include the Application ID ("01") in the data being transmitted.
*Enable RSS-14 &
RSS Expanded
(Groups I, II) Disable Transmit RSS-14 Code ID
*Do Not Transmit
*Transmit RSS-14 Application ID Do Not Transmit GS1 Formatting for GS1 DataBar Omnidirectional Decide whether to enable GS1 formatting for GS1 DataBar Omnidirectional. When enabled, the field separator and application ID mark characters will be automatically added to the output data. 147 Update 148 1662/1664 Barcode Scanner User Guide 4.13.3 GS1 DATABAR EXPANDED (RSS EXPANDED) Enable
*Disable
*Enable RSS-14 &
RSS Expanded
(Groups I, II) Disable Enter Setup When GS1 formatting for GS1 DataBar Expanded is enabled, code ID transmitting will be disabled. The settings below apply to Group II symbologies only:
GS1 DataBar Expanded GS1 DataBar Expanded Stacked Transmit Code ID Decide whether to include the Code ID in the data being transmitted. Transmit RSS Expanded Code ID
*Do Not Transmit GS1 Formatting for GS1 DataBar Expanded Decide whether to enable GS1 formatting for GS1 DataBar Expanded. When enabled, the field separator and application ID mark characters will be automatically added to the output data. Enable Chapter 4 Change Symbology Settings
*Disable 4.13.4 GS1 DATABAR LIMITED (RSS LIMITED)
*Enable RSS Limited
(Group III) Disable Transmit RSS Limited Code ID
*Do Not Transmit
*Transmit RSS Limited Application ID Do Not Transmit When GS1 formatting for GS1 DataBar Limited is enabled, code ID transmitting will be disabled; however, application ID transmitting will be enabled automatically. Transmit Code ID Decide whether to include the Code ID in the data being transmitted. Transmit Application ID Decide whether to include the Application ID ("01") in the data being transmitted. GS1 Formatting for GS1 DataBar Limited Decide whether to enable GS1 formatting for GS1 DataBar Limited. When enabled, the field separator and application ID mark characters will be automatically added to the output data. Enable 149 Update 1662/1664 Barcode Scanner User Guide
*Disable 4.13.5 CONVERT TO UPC/EAN This only applies to GS1 DataBar Omnidirectional and GS1 DataBar Limited barcodes not decoded as part of a Composite barcode. Convert to EAN-13: It will strip the leading 010 from barcodes. 01 is the Application ID and must be followed by a single zero (the first digit encoded). Convert to UPC-A: It will strip the leading 0100 from barcodes. 01 is the Application ID and must be followed by two or more zeros (but not six zeros). Convert to UPC/EAN
*Do Not Convert Specify Field Separator 4.13.6 FIELD SEPARATOR (GS CHARACTER) Decide whether to apply a field separator (to convert the GS control character to human readable character). The field separator is automatically added to the data when GS1 formatting is enabled. 1) Read the barcode above to specify field separator. 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. 3) Read the Validate barcode to complete this setting. 150 Enter Setup Chapter 4 Change Symbology Settings 4.13.7 APPLICATION ID MARK You may want to add an application ID mark (1 character long) to the left (AIMark1) or right (AIMark2) of an application ID (AI) for the purpose of labeling it when formatting the GS1 data. The application ID mark is automatically added to the data when GS1 formatting is enabled. AIMark1 AIMark2 1) Read the barcode above to add a mark to the left (AIMark1)/right (AIMark2) of an application ID. 2) Read the Hexadecimal System barcode on page 272 for the desired character. Read
'00' if you want to remove the AI mark. 3) Read the Validate barcode to complete this setting. 151 Update 1662/1664 Barcode Scanner User Guide 4.14 MSI 4.14.1 VERIFY CHECK DIGIT Select one of the three calculations to verify check digit(s) when decoding barcodes. If incorrect, the barcode will not be accepted. Enable
*Disable
*Single Modulo 10 Double Modulo 10 Modulo 10 & 11
*Last Digit Not Transmitted Both Digits Transmitted Both Digits Not Transmitted 4.14.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit(s) in the data being transmitted. 152 Enter Setup Chapter 4 Change Symbology Settings 4.14.3 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If Fixed Length is selected, up to 2 fixed lengths can be specified. Note: The specified length(s) must include the check digit(s) the barcode contains. 1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification. 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2. 3) Read the Decimal Value barcode on page 271 for the desired length. 4) Read the Validate barcode on the same page to complete this setting.
*Enable Max./Min. Length (1~55) Enable Fixed Length(s) Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 Update 153 1662/1664 Barcode Scanner User Guide 4.15 EAN-8 EAN-8 EAN-8 Addon 2 EAN-8 Addon 5
*Enable EAN-8
(No Addon) Disable Enable EAN-8 Addon 2
*Disable Enable EAN-8 Addon 5
*Disable
*Transmit EAN-8 Check Digit Do Not Transmit 4.15.1 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. 154 Enter Setup Chapter 4 Change Symbology Settings Decide whether to read EAN-13 barcodes ending with Addon 2. Decide whether to read EAN-13 barcodes ending with Addon 5.
*Enable EAN-13
(No Addon) Disable Enable EAN-13 Addon 2
*Disable Enable EAN-13 Addon 5
*Disable 4.16 EAN-13 EAN-13 EAN-13 Addon 2 EAN-13 Addon 5 155 Update 156 1662/1664 Barcode Scanner User Guide 4.16.1 EAN-13 ADDON MODES EAN-13 414/419/434/439 Addon Mode Decide whether to enable EAN-13 414/419/434/439 Addon Mode. When enabled, barcodes starting with 414/419/434/439 wont be decoded if the scanned barcodes do not have the Addon 2 or Addon 5 suffix. Decide whether to enable EAN-13 378/379 Addon Mode. When enabled, barcodes starting with 378/379 wont be decoded if the scanned barcodes do not have the Addon 2 or Addon 5 suffix. EAN-13 378/379 Addon Mode Decide whether to enable EAN-13 977 Addon Mode. When enabled, barcodes starting with 977 wont be decoded if the scanned barcodes do not have the Addon 2 or Addon 5 suffix. EAN-13 977 Addon Mode Enable
*Disable Enable
*Disable Enable
*Disable Enter Setup EAN-13 978 Addon Mode EAN-13 979 Addon Mode EAN-13 491 Addon Mode Chapter 4 Change Symbology Settings Decide whether to enable EAN-13 978 Addon Mode. When enabled, barcodes starting with 978 wont be decoded if the scanned barcodes do not have the Addon 2 or Addon 5 suffix. Decide whether to enable EAN-13 979 Addon Mode. When enabled, barcodes starting with 979 wont be decoded if the scanned barcodes do not have the Addon 2 or Addon 5 suffix. Decide whether to enable EAN-13 491 Addon Mode. When enabled, barcodes starting with 491 wont be decoded if the scanned barcodes do not have the Addon 2 or Addon 5 suffix. Enable
*Disable Enable
*Disable Enable
*Disable 157 Update 1662/1664 Barcode Scanner User Guide Decide whether to enable EAN-13 529 Addon Mode. When enabled, barcodes starting with 529 wont be decoded if the scanned barcodes do not have the Addon 2 or Addon 5 suffix. Decide whether to have the scanner buzzer sound two beeps (with tones descending from high to low) when decoding the scanned barcode that doesnt have the Addon 2 or Addon 5 suffix. Enable
*Disable Enable
*Disable EAN-13 529 Addon Mode EAN-13 Addon Mode Buzzer 158 Enter Setup Chapter 4 Change Symbology Settings 4.16.2 CONVERT TO ISBN Decide whether to convert the EAN-13 barcode, starting with 978, to ISBN. 4.16.3 CONVERT TO ISSN (1664 ONLY) Decide whether to convert the EAN-13 barcode, starting with 977 to ISSN. 4.16.4 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. Convert EAN-13 to ISBN
*Do Not Convert Convert EAN-13 to ISSN
*Do Not Convert
*Transmit EAN-13 Check Digit Do Not Transmit Update 159 1662/1664 Barcode Scanner User Guide 4.17 UCC COUPON EXTENDED CODE Decide whether to decode the following barcodes as Coupon Code. UPC-A barcodes starting with digit 5 EAN-13 barcodes starting with digits 99 UPC-A/EAN-128 Coupon Codes Enable
*Disable Note: Depending on your requirements, UPC-A, EAN-13 and EAN-128 must be enabled first!
160 Enter Setup 4.18 UPC-A UPC-A UPC-A Addon 2 UPC-A Addon 5 Chapter 4 Change Symbology Settings
*Enable UPC-A
(No Addon) Disable Enable UPC-A Addon 2
*Disable Enable UPC-A Addon 5
*Disable 161 Update 1662/1664 Barcode Scanner User Guide 4.18.1 CONVERT TO EAN-13 Decide whether to expand the read UPC-A barcode, as well as its addons, into EAN-13. After conversion, the data follows EAN-13 format and is affected by EAN-13 programming selections (e.g. Check Digit). 4.18.2 TRANSMIT SYSTEM NUMBER Decide whether to include the system number in the data being transmitted. 4.18.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. Convert UPC-A to EAN-13
*Do Not Convert
*Transmit UPC-A System Number Do Not Transmit
*Transmit UPC-A Check Digit Do Not Transmit 162 Enter Setup 4.19 UPC-E UPC-E UPC-E Addon 2 UPC-E Addon 5 Chapter 4 Change Symbology Settings
*Enable UPC-E
(No Addon) Disable Enable UPC-E Addon 2
*Disable Enable UPC-E Addon 5
*Disable 163 Update 1662/1664 Barcode Scanner User Guide 4.19.1 SELECT SYSTEM NUMBER Decide whether to decode the ordinary UPC-E barcodes only or both UPC-E0 and UPC-E1 barcodes. System number 0 enabled for decoding UPC-E0 barcodes. System number 1 enabled for decoding UPC-E1 barcodes. Warning: Because of the way system number 1 is encoded, if both system numbers are enabled, the user might suffer from short scanning UPC-A or EAN-13 barcodes into UPC-E1 barcodes. 4.19.2 CONVERT TO UPC-A Decide whether to expand the read UPC-E barcode, as well as its addons, into UPC-A. After conversion, the data follows UPC-A format and is affected by UPC-A programming selections (e.g. System Number, Check Digit). System Number 0 & 1
*System Number 0 Only Convert UPC-E to UPC-A
*Do Not Convert 164 Enter Setup Chapter 4 Change Symbology Settings 4.19.3 TRANSMIT SYSTEM NUMBER Decide whether to include the system number in the data being transmitted. 4.19.4 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. Transmit UPC-E System Number
*Do Not Transmit
*Transmit UPC-E Check Digit Do Not Transmit 165 Update 166 1662/1664 Barcode Scanner User Guide 4.20 CODE 11 4.20.1 VERIFY CHECK DIGIT Decide whether to verify the check digit(s). If incorrect, the barcode will not be accepted. Enable
*Disable Verify One Check Digit Verify Two Check Digit
*Do Not Verify Transmit Code 11 Check Digit
*Do Not Transmit Enter Setup 4.20.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit(s) in the data being transmitted. Note: "Verify Check Digit" must be enabled first. Chapter 4 Change Symbology Settings 4.20.3 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If Fixed Length is selected, up to 2 fixed lengths can be specified. Note: The specified length(s) must include the check digit(s) the barcode contains. 1) Read the barcode to enable either Max. /Min. Length qualification or Fixed Length(s) qualification. 2) Read the barcode for Max. Length or Fixed Length 1, and follow steps 3~4. Repeat steps 2~4 for Min. Length or Fixed Length 2. 3) Read the Decimal Value barcode on page 271 for the desired length. 4) Read the Validate barcode on the same page to complete this setting.
*Enable Max./Min. Length (1~55) Enable Fixed Length(s) Max. Length (*55) or Fixed Length 1 Min. Length (*4) or Fixed Length 2 Update 167 1662/1664 Barcode Scanner User Guide 4.21 COMPOSITE CODE 4.21.1 COMPOSITE CC-A/B Decide whether to enable Composite CC-A/B. Decide whether to enable GS1 formatting for Composite CC-A/B. When enabled, the field separator and application ID mark will be automatically added to the output data. 4.21.2 COMPOSITE CC-C Decide whether to enable Composite CC-C. Decide whether to enable GS1 formatting for Composite CC-C. When enabled, the field separator and application ID mark will be automatically added to the output data. Enable Composite CC-A/B
*Disable Enable
*Disable Enable Composite CC-C
*Disable Enable
*Disable 168 Enter Setup 4.21.3 COMPOSITE TLC-39 Chapter 4 Change Symbology Settings 4.21.4 UPC COMPOSITE MODE UPC barcodes can be linked with a 2D barcode during transmission as if they were one barcode. UPC Never Linked UPC Always Linked Transmit UPC barcodes regardless of whether a 2D barcode is detected. Transmit UPC barcodes and the 2D portion. If the 2D portion is not detected, the UPC barcode will not be transmitted. Note: CC-A/B or CC-C must be enabled!
Auto-discriminate UPC Composites Transmit UPC barcodes as well as the 2D portion if present. Enable Composite TLC-39
*Disable UPC Never Linked
*UPC Always Linked Auto-discriminate Update 169 1662/1664 Barcode Scanner User Guide 4.21.5 GS1-128 EMULATION MODE FOR UCC/EAN COMPOSITE CODES Decide whether to transmit UCC/EAN Composite Code data as if it was encoded in GS1-
128 barcodes. 4.21.6 FIELD SEPARATOR (GS CHARACTER) Decide whether to apply a field separator (to convert the GS control character to human readable character). The field separator is automatically added to the data when GS1 formatting is enabled. Enable GS1-128 Emulation Mode
*Disable Specify Field Separator 1) Read the barcode above to specify field separator. 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. 3) Read the Validate barcode to complete this setting. 170 Enter Setup Chapter 4 Change Symbology Settings 4.21.7 APPLICATION ID MARK You may want to add an application ID mark (1 character long) to the left (AIMark1) or right (AIMark2) of an application ID (AI) for the purpose of labeling it when formatting the GS1 data. The application ID mark is automatically added to the data when GS1 formatting is enabled. AIMark1 AIMark2 1) Read the barcode above to add a mark to the left (AIMark1)/right (AIMark2) of an application ID. 2) Read the Hexadecimal System barcode on page 272 for the desired character. Read
'00' if you want to remove the AI mark. 3) Read the Validate barcode to complete this setting. 171 Update 1662/1664 Barcode Scanner User Guide 4.22 US POSTAL CODE 4.22.1 US POSTNET 4.22.2 US PLANET
*Enable US Postnet Disable
*Enable US Planet Disable
*Transmit US Postal Check Digit Do Not Transmit 4.22.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. 172 Enter Setup Chapter 4 Change Symbology Settings 4.23 UK POSTAL CODE 4.23.1 UK POSTAL 4.23.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.
*Enable UK Postal Disable
*Transmit UK Postal Check Digit Do Not Transmit 173 Update 1662/1664 Barcode Scanner User Guide 4.24 MORE POSTAL CODE 4.24.1 JAPAN POSTAL 4.24.2 AUSTRALIAN POSTAL 4.24.3 DUTCH POSTAL 4.24.4 USPS 4CB/ONE CODE/INTELLIGENT MAIL
*Enable Japan Postal Disable
*Enable Australian Postal Disable
*Enable Dutch Postal Disable Enable USPS 4CB/
One Code/
Intelligent Mail
*Disable 174 Enter Setup 4.24.5 UPU FICS POSTAL Chapter 4 Change Symbology Settings Enable UPU FICS Postal
*Disable 175 Update 1662/1664 Barcode Scanner User Guide 4.25 2D SYMBOLOGIES 4.25.1 PDF417 4.25.2 MicroPDF417
*Enable PDF417 Disable Enable MicroPDF417
*Disable 176 Enter Setup 4.25.3 DATA MATRIX Chapter 4 Change Symbology Settings Data Matrix Mirror Decide whether to decode mirror image Data Matrix barcodes. Never do not decode Data Matrix barcodes that are mirror images. Always decode only Data matrix barcodes that are mirror images. Auto decode both mirrored and unmirrored Data Matrix barcoes.
*Enable Data Matrix Disable
*Never Always Auto 177 Update 1662/1664 Barcode Scanner User Guide 4.25.4 MAXICODE 4.25.5 QR CODE 4.25.6 MicroQR 4.25.7 AZTEC
*Enable Maxicode Disable
*Enable QR Code Disable
*Enable MicroQR Disable
*Enable Aztec Disable 178 Enter Setup Chapter 4 Change Symbology Settings 4.26 MACRO PDF Macro PDF is a special feature for concatenating multiple PDF barcodes into one file, known as Macro PDF417 or Macro MicroPDF417. Note: When printing barcodes, keep each Macro PDF sequence separate, as each has a unique identifier. Do not mix barcodes from several Macro PDF sequences, even if they encode the same data. When you scan Macro PDF sequences, scan the entire Macro PDF sequence without interruption!
4.26.1 TRANSMIT/DECODE MODE Decide how to handle Macro PDF decoding. Buffer All Symbols / Transmit Macro PDF When Complete Transmit all decoded data from an entire Macro PDF sequence only when the entire sequence is scanned and decoded. If the decoded data exceeds the limit of 50 symbols, no transmission because the entire sequence was not scanned!
Transmit Any Symbol in Set / No Particular Order Transmit data from each Macro PDF symbol as decoded, regardless of the sequence. Passthrough All Symbols Transmit and decode all Macro PDF symbols and perform no processing. In this mode, the host is responsible for detecting and parsing the Macro PDF sequences. Buffer All Symbols /
Transmit When Complete Transmit Any Symbol in Set /
No Particular Order
*Passthrough All Symbols Update 179 1662/1664 Barcode Scanner User Guide 4.26.2 ESCAPE CHARACTERS When enabled, it uses the backslash "\" as an Escape character for systems that can process transmissions containing special data sequences. It will format special data according to the Global Label Identifier (GLI) protocol, which only affects the data portion of a Macro PDF symbol transmission. The Control Header, if enabled, is always sent with GLI formatting. 4.26.3 TRANSMIT CONTROL HEADER The control header contains the segment index and file ID. For example, the field may be
\92800000\725\120\343. The five digits after the \928 are the segment index (or block index), and \725\120\343 is the file ID. Enable this when selecting Transmit Any Symbol in Set/ No Particular Order. Disable this when selecting Buffer All Symbols/Transmit Macro PDF When Complete. This option has no effect when selecting "Passthrough All Symbols". GLI Protocol
*None Transmit Control Header
*Do Not Transmit 180 Enter Setup Chapter 5 DEFINING OUTPUT FORMAT You may configure the format of the collected data output to the host computer. Barcodes read by the scanner will be processed in the following sequence 1) Perform character substitution on the data scanned. 2) Add Code ID and Length Code to the front of the data:[Code ID][Length Code][Data]
3) Process the whole data in step 2 with user formats. Data is now divided into fields by user specified rules. Refer to Chapter 6 Applying Formats for Data Editing. 4) Add Prefix Code and Suffix Code before transmission:[Prefix Code][Processed Data][Suffix Code]
IN THIS CHAPTER 5.1 Letter Case .............................................................. 181 5.2 Character Substitution ............................................... 182 5.3 Prefix/Suffix Code ..................................................... 196 5.4 Code ID ................................................................... 197 5.5 Length Code............................................................. 204 5.6 Multi-Barcode Editor .................................................. 212 5.7 Removal of Special Character ..................................... 216 5.8 AIM Code ID ............................................................... 216 5.1 LETTER CASE By default, the alphabetics transmission is case-sensitive, meaning that the alphabet will be transmitted according to their original case. Ignoring the original letter case, select
[Upper Case] to output data in upper case only; otherwise, select [Lower Case] to output data in lower case only. 181
*Normal Upper Case Lower Case Update 1662/1664 Barcode Scanner User Guide 5.2 CHARACTER SUBSTITUTION Character substitution is performed on every occurrence of the first character specified. If only one character is specified, every occurrence of that character in the barcode will be taken away. The first character will be replaced by the second character(s). Up to three sets of character substitution can be configured. If Bluetooth HID or USB HID is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when Normal Key is selected for Key Type. Key Type Key Status Scan Code Only 1 scan code Refer Substituion. to 5.2.1 value Single is allowed. Character N/A Normal Key Up to 3 character strings are allowed. Add Shift Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt Refer to Keyboard Wedge Table. Note: The character substitution is performed only on the barcode itself and before the processing of editing formats. It is not applicable to the Prefix/Suffix Code, Code ID, Length Code, or any Additional Field. 182 Enter Setup 5.2.1 SINGLE CHARACTER SUBSTITUION Chapter 5 Defining Output Format Configure Set 1 Configure Set 2 Configure Set 3 1) Read the barcode above to enable character substitution by set. For example, read the Set 1 barcode to configure the first set of character substitution. The scanner will respond with one short beep, high tone, to indicate more setup barcodes are required. 2) Read the Hexadecimal Value barcode on page 272 for the desired character substitution. For example, KEY TYPE = NORMAL Read 3, 0, 2, and D to replace the character 0 with a dash -. Read 3, 0, 2, D, 3, and 0 to replace the character 0 with a dash -0. If you want to replace the character 0 with a (= 1C on the scan code table):
KEY TYPE = SCAN CODE 1. Read 3 and 0. 2. Read the Scan Code barcode. 3. Read 1 and C. KEY TYPE = NORMAL + KEY STATUS = SHIFT 1. Read 3 and 0. 2. Read the Add Shift barcode. 3. Read 3 and 1. If you want to replace the character 0 with ! (= Shift + 1 on keyboard):
3) Read the Validate barcode to complete this setting. (The defined set or sets will be applied to all symbologies by default.) 183 Update 1662/1664 Barcode Scanner User Guide 5.2.2 MULTIPLE CHARACTER SUBSTITUTION Users can replace a string up to 16 characters with another one. Configure Set 1 Set 1 Target String Configure Set 2 Set 2 Target String Configure Set 3 Set 3 Target String Set 1 Replacement String Set 2 Replacement String Set 3 Replacement String Please follow steps below:
1) Respectively read the Target String and Replacement String barcodes above to enable string substitution by set. For example, have the scanner read the Target String barcode of Set 1 to specify the target characters to be replaced. Then the scanner will respond with one short beep indicating users to proceed with barcode reading for target characters. Read the Hexadecimal System barcode on page 272 for the desired characters. 2) After specifying the target characters, have the scanner read the Replacement String barcode of Set 1 to specify the replacement characters. Read the Hexadecimal System barcode on page 272 for the desired characters. For example, 184 Enter Setup Chapter 5 Defining Output Format 2. Read 3, 0, 2, D, 3, and 0 barcodes to specify the target string 0-0 (zero, 4. Read 2, A, 2, A, 2, and A barcodes to specify the replacement string ***
Replace the character 0-0 with *** (* = 3E on the scan code table):
2. Read 3, 0, 2, D, 3, and 0 barcodes to specify the target string 0-0 (zero, 5. Read 3, E, 3, E, 3, and E barcodes to specify the replacement string ***
Replace the character 0-0 with !!! (! = Shift + 1 on keyboard):
1. Read the Target String barcode. 2. Read 3, 0, 2, D, 3, and 0 barcodes to specify the target string 0-0 (zero, KEY TYPE = NORMAL Replace the character 0-0 with ***:
1. Read the Target String barcode. dash, zero). 3. Read the Replacement String barcode.
(stars). KEY TYPE = SCAN CODE 1. Read the Target String barcode. dash, zero). 3. Read the Replacement String barcode. 4. Read the Scan Code barcode.
(stars). KEY TYPE = NORMAL + KEY STATUS = SHIFT dash, zero). 3. Read the Replacement String barcode. 4. Read the Add Shift barcode. 5. Read 3, 1, 3, 1, 3, and 1. 3) Read the Validate barcode to complete this setting. (The defined set or sets will be applied to all symbologies by default.) 185 Update 5.2.3 SYMBOLOGIES FOR CHARACTER SUBSTITUTION (ALL 3 SETS) By default character substitution will be performed on all symbologies. If the character substitution is not desired with one or more symbologies, read the Do Not Apply barcode for each undesired symbologies and all the three sets will be ignored for them. 1662/1664 Barcode Scanner User Guide 186 Character Substitution for Codabar Character Substitution for Code 39 Character Substitution for Trioptic Code 39 Character Substitution for Code 93
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply Enter Setup Chapter 5 Defining Output Format Character Substitution for Code 128 Character Substitution for GS1-128 Character Substitution for ISBT 128 Character Substitution for EAN-8 (No Addon) Character Substitution for EAN-8 Addon 2
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Update 187 1662/1664 Barcode Scanner User Guide Character Substitution for EAN-8 Addon 5 Character Substitution for EAN-13 (No Addon) Character Substitution for EAN-13 Addon 2 Character Substitution for EAN-13 Addon 5 Character Substitution for Italian Pharmacode 188 Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Enter Setup Chapter 5 Defining Output Format Character Substitution for Industrial 25 Character Substitution for Interleaved 25 Character Substitution for Matrix 25 Character Substitution for Chinese 25 Character Substitution for MSI Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Update 189 1662/1664 Barcode Scanner User Guide Character Substitution for GS1 DataBar Character Substitution for UPC-A (No Addon) Character Substitution for UPC-A Addon 2 Character Substitution for UPC-A Addon 5 Character Substitution for UPC-E (No Addon) 190 Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Enter Setup Chapter 5 Defining Output Format Character Substitution for UPC-E Addon 2 Character Substitution for UPC-E Addon 5 Character Substitution for UCC Coupon Extended Code Character Substitution for Code 11 Character Substitution for Composite CC-A/B Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Update 191 1662/1664 Barcode Scanner User Guide Character Substitution for Composite CC-C Character Substitution for Composite TLC-39 Character Substitution for US Postnet Character Substitution for US Planet Character Substitution for UK Postal 192 Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Enter Setup Chapter 5 Defining Output Format Character Substitution for Japan Postal Character Substitution for Australian Postal Character Substitution for Dutch Postal Character Substitution for USPS 4CB/One Code/Intelligent Mail Character Substitution for UPU FICS Postal Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Update 193 1662/1664 Barcode Scanner User Guide Character Substitution for PDF417 Character Substitution for MicroPDF417 Character Substitution for Data Matrix Character Substitution for Maxicode Character Substitution for QR Code 194 Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Enter Setup Chapter 5 Defining Output Format Character Substitution for MicroQR Character Substitution for Aztec Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply 195 Update 1662/1664 Barcode Scanner User Guide 5.3 PREFIX/SUFFIX CODE By default, there is no prefix code, and [ENTER] or [CR] (Carriage Return) is configured to be suffix code. Up to 8 characters can be configured, for example, Barcode_, and you will have the string appear like this Barcode_1234567890. in front of the barcode read, If Bluetooth HID or USB HID is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when Normal Key is selected for Key Type. Key Type Key Status Scan Code Up to 4 scan code values are allowed. N/A Normal Key Up to 8 character strings are allowed. Add Shift Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt Refer to Keyboard Wedge Table. Configure Prefix Configure Suffix 1) Read the barcode above to apply prefix code or suffix code separately, and follow steps 2~3. (Max. 8 characters each) 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. For example, read 2 and B for the scanner to prefix or suffix the character [+]. 3) Read the Validate barcode to complete this setting. 196 Enter Setup Chapter 5 Defining Output Format 5.4 CODE ID Up to two characters for Code ID can be configured for each symbology. To make the Code ID configuration easier, the scanner provides five pre-defined Code ID sets that you can select one and make necessary changes on it. If Bluetooth HID or USB HID is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when Normal Key is selected for Key Type. Key Type Key Status Scan Code Only 1 scan code value is allowed. Normal Key Up to 2 character strings are allowed. Add Shift N/A Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt Refer to Keyboard Wedge Table. Note: "]C1" is the Code ID of GS1-128 (EAN-128) barcodes; "]e0" is the default Code ID of GS1 DataBar (RSS) barcodes. 5.4.1 SELECT PRE-DEFINED CODE ID Apply Code ID Set 1 Apply Code ID Set 2 Apply Code ID Set 3 Apply Code ID Set 4 Apply Code ID Set 5 197 Update 1662/1664 Barcode Scanner User Guide Set 1 Set 2 Set 3 Set 4 Set 5 Code ID options Code 39 Trioptic Code 39 Italian Pharmacode Industrial 25 Interleaved 25 Matrix 25 Chinese 25 Codabar Code 93 Code 128 ISBT 128 UPC-E EAN-8 EAN-13 UPC-A MSI UCC Coupon Code Code 11 Composite CC-A/B Composite CC-C Composite TLC-39 US Postnet US Planet UK Postal Japan Postal Australian Postal Dutch Postal UPU FICS Postal PDF417 MicroPDF417 Data Matrix Maxicode QR Code 198 USPS 4 CB / One Code / Intelligent Mail A A A C D E Q F I H H S P M J V G K L N O h i j k l m n o a b c d e C C C H I G M N L K K E B A A V F J X Y Z a b c d e f g h O P Q R S Y Y Y H Z G P X L K K C B A A D I J M N O s t u v w x y z W V U T S FF M M M H I G S N L K K E F A P C D J O R i j k l n o p T U V m W X A X A S S S X F G C C E E E E M C H X X X X X X X X L L d U Q La Lc L2 Enter Setup Chapter 5 Defining Output Format MicroQR Aztec IATA Macro PDF417 Macro MicroPDF417 f g z p q T U z i j R Q r a b Y Z h q r Q z S L L 199 Update 1662/1664 Barcode Scanner User Guide 5.4.2 CHANGE CODE ID 1) Read the barcode below to change code ID of a specific symbology. 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. For example, read 4 and 4 for applying the character [D] for Code ID. 3) Read the Validate barcode to complete this setting. Configure Code ID for Codabar Configure Code ID for Code 39 Configure Code ID for Trioptic Code 39 Configure Code ID for Code 93 Configure Code ID for Code 128 Configure Code ID for ISBT 128 Configure Code ID for EAN-8 Configure Code ID for EAN-13 Configure Code ID for Italian Pharmacode Configure Code ID for Industrial 25 200 Enter Setup Chapter 5 Defining Output Format Configure Code ID for Interleaved 25 Configure Code ID for Matrix 25 Configure Code ID for Chinese 25 Configure Code ID for MSI Configure Code ID for UPC-A Configure Code ID for UPC-E Configure Code ID for UCC Coupon Code Configure Code ID for Code 11 Configure Code ID for Composite CC-A/B Configure Code ID for Composite CC-C Configure Code ID for Composite TLC-39 Configure Code ID for US Postnet 201 Update 1662/1664 Barcode Scanner User Guide Configure Code ID for US Planet Configure Code ID for UK Postal Configure Code ID for Japan Postal Configure Code ID for Australian Postal Configure Code ID for Dutch Postal Configure Code ID for USPS 4CB / One Code /
Intelligent Mail Configure Code ID for UPU FICS Postal Configure Code ID for PDF417 Configure Code ID for MicroPDF417 Configure Code ID for Data Matrix Configure Code ID for Maxicode Configure Code ID for QR Code 202 Enter Setup 5.4.3 CLEAR CODE ID SETTINGS Chapter 5 Defining Output Format Configure Code ID for MicroQR Configure Code ID for Aztec Configure Code ID for IATA Configure Code ID for Macro PDF417 Configure Code ID for Macro MicroPDF417 Clear All Code ID Settings 203 Update 1662/1664 Barcode Scanner User Guide 5.5 LENGTH CODE A 4-digit code representing the length of barcode data (character count) can be inserted in front of data being transmitted. Such "Length" code can be individually enabled or disabled for each symbology. Length Code for Codabar Length Code for Code 39 Length Code for Trioptic Code 39 Length Code for Code 93 204 Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Enter Setup Chapter 5 Defining Output Format Length Code for Code 128 Length Code for GS1-128 & GS1 DataBar Length Code for ISBT 128 Length Code for EAN-8 Length Code for EAN-13 Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Update 205 1662/1664 Barcode Scanner User Guide Length Code for Italian Pharmacode Length Code for Industrial 25 Length Code for Interleaved 25 Length Code for Matrix 25 Length Code for Chinese 25 206 Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Enter Setup Chapter 5 Defining Output Format Length Code for MSI Length Code for UPC-A Length Code for UPC-E Length Code for UCC Coupon Extended Code Length Code for Code 11 Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Update 207 1662/1664 Barcode Scanner User Guide Length Code for Composite CC-A/B Length Code for Composite CC-C Length Code for Composite TLC-39 Length Code for US Postnet Length Code for US Planet 208 Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Enter Setup Chapter 5 Defining Output Format Length Code for UK Postal Length Code for Japan Postal Length Code for Australian Postal Length Code for Dutch Postal Length Code for USPS 4CB/One Code/Intelligent Mail Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Update 209 1662/1664 Barcode Scanner User Guide Length Code for UPU FICS Postal Length Code for PDF417 Length Code for MicroPDF417 Length Code for Data Matrix Length Code for Maxicode 210 Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply Enter Setup Length Code for QR Code Length Code for MicroQR Length Code for Aztec Chapter 5 Defining Output Format Apply
*Do Not Apply Apply
*Do Not Apply Apply
*Do Not Apply 211 Update 1662/1664 Barcode Scanner User Guide 5.6 MULTI-BARCODE EDITOR The Multi-Barcode Editor allows deciding the output sequence of a concatenation of barcodes. Up to five barcodes can be specified. Enabling this function will force the scanner to apply Laser mode as the scan mode. Note: The Multi-Barcode Editor has nothing to do with 1.7.5 Multi-Barcode Mode. The barcodes that are found meeting the specified criteria below will be arranged in the desired sequence. Code Type 4-digit barcode length, excluding prefix, suffix, length code, etc. Matching the first character of barcode data 212 Enter Setup Chapter 5 Defining Output Format 5.6.1 EDIT A CONCATENATION OF BARCODES Edit Output Sequence 1) Read the barcode above to start editing a concatenation of barcodes. 2) Code Type setting read the Hexadecimal Value barcode on page 272 for Code Type of the (first) barcode. For example, read 4 and 1 for Code 39. Code Type Symbology Code Type Symbology 40 (@) ISBT 128 41 (A) Code 39 42 (B) Italian Pharmacode 43 (C) N/A 46 (F) Matrix 25 48 (H) Code 93 Code 128 49 (I) 4A (J) 44 (D) Industrial 25 64 (d) TLC-39 (TCIF Linked Code 39) 45 (E) Interleaved 25 65 (e) Trioptic Code 39 47 (G) Codabar (NW7) 67 (g) Code 11 UPC-E0 / UPC-E1 6A (j) Composite CC-C 4B (K) UPC-E with Addon 2 6B (k) PDF417 4C (L) UPC-E with Addon 5 6C (l) MicroPDF417 4D (M) EAN-8 6D (m) Data Matrix 4E (N) EAN-8 with Addon 2 6E (n) Maxicode 4F (O) EAN-8 with Addon 5 6F (o) QR Code 50 (P) EAN-13 70 (p) US Postnet 51 (Q) EAN-13 with Addon 2 71 (q) US Planet 52 (R) EAN-13 with Addon 5 72 (r) UK Postal 53 (S) 54 (T) MSI N/A 73 (s) Japan Postal 74 (t) Australian Postal 55 (U) GS1-128 (EAN-128) 75 (u) Dutch Postal 56 (V) UPC-A 76 (v) Composite CC-A/B 57 (W) UPC-A with Addon 2 77 (w) Macro PDF417 58 (X) UPC-A with Addon 5 78 (x) Macro MicroPDF417 213 Update 1662/1664 Barcode Scanner User Guide 5A (Z) N/A 5B ( [ ) GS1 DataBar (RSS) 7B ({) Micro QR 79 (y) Chinese 25 7A (z) Aztec 7C (|) USPS 4CB / One Code /
Intelligent Mail 7D (}) UPU FICS Postal 7E (~) UCC Coupon Extended Code 3) Barcode Length setting read the Decimal Value barcode on page 271 for the 4-
digit length of the (first) barcode. For example, read 0065 for barcode length of 65 characters or read 0000 for any length. Note: If not reading 0000 for any length, the 4-digit length must exclude prefix, suffix
(0x0d by default), length code, etc. 4) Matching Character setting read the Hexadecimal Value barcode on page 272 for the 1st character that must be found matching in the (first) barcode. For example, read 4 and 1 for matching character A as the first character in the barcode or read 00 for any character. 5) Read twice the F barcode on page 272 (FF) to complete the setting of each barcode. 6) Read the Validate barcode to end the editing of the barcode set. 214 Enter Setup Chapter 5 Defining Output Format 5.6.2 ACTIVATE THE CONCATENATION OF BARCODES By default, the output sequence editing of the concatenation of barcodes is not applied. When Enforce Output Sequence is enabled, all barcodes read by the scanner must meet with the criteria for the concatenation. If data is found excluded from all output sequence sets (= not meeting with the criteria), the scanner will not accept the reading, and therefore, data will not be transmitted. When Apply Output Sequence is enabled, only barcodes found meeting with the criteria are counted for the concatenation. Those found not meeting with the criteria are processed normally and individually. Note: When it requires reading more barcodes to complete the output sequence requirements, the scanner will respond with one short beep (low tone). After reading an acceptable barcode, its LED indicator will become solid green and go off
(= Good Read). Upon completion of reading acceptable barcodes, the scanner will respond with one short beep (high tone) and its LED indicator will become solid green and go off
(= Good Read). Warning: When you disable the Multi-Barcode Editor later, the scan mode remains unchanged. If Laser mode is not desired, proceed to select a scan mode that best suits your application.
*Ignore Output Sequence Enforce Output Sequence Apply Output Sequence Update 215 1662/1664 Barcode Scanner User Guide 5.7 REMOVAL OF SPECIAL CHARACTER You can only specify 1 character, but it will remove every matching character encountered from the starting position of barcode data until a different character is met. For example, if it is configured to remove the character 0 (hex value is 30), one or more zeros will be stripped off the barcode data 012345 and 00012345. However, for barcode data 010333, only the first zero will be stripped off. Remove Special Character 1) Read the barcode above to remove the specified character. 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. For example, read 3 and 0 for the scanner to remove the character 0. 3) Read the Validate barcode to complete this setting. 5.8 AIM CODE ID You can add an AIM (Automatic Identification and Mobility) code ID in front of the barcode that share the common purpose of identifying, tracking, recording, storing and communicating essential business, personal or product data. Enabling this function can have the scanner be capable of fast and accurate data collection and search. Enable
*Disable 216 Enter Setup Chapter 6 APPLYING FORMATS FOR DATA EDITING The scanner allows advanced data editing by applying user-configured editing formats. The whole processed data can be divided into fields by user-specified rules. These fields together with the user-configurable additional fields consist of the data actually sent to the host computer. For 1662/1664 to apply any editing format, the maximum output data length of a barcode is 7 KB after configuration. When the data length exceeds 7 KB, editing format will not take effect.
[Time Stamp]
[Prefix Code]
[Code ID]
[Length Code]
[Data]
Additional Field(s)
[Time Stamp]
[Suffix Code]
None by None by None None by by None by Barcode itself None 0x0d by by default default default default default default default IN THIS CHAPTER 6.1 Activating Editing Formats .......................................... 218 6.2 How to Configure Editing Formats ............................... 220 6.3 Configure Format Define Data Criteria ...................... 223 6.4 Configure Format Define Data Field .......................... 235 6.5 Configure Format Define Transmission Sequence 244 6.6 Programming Examples ............................................. 246 217 Update 1662/1664 Barcode Scanner User Guide 6.1 ACTIVATING EDITING FORMATS 6.1.1 ACTIVATE EDITING FORMATS If you have already configured any editing format before, you may directly apply the editing format. If not, you must start with configuring an editing format first, and then, activate the editing format when it is desired in use. Editing Format 1 Editing Format 2 Editing Format 3 Editing Format 4 218 Enable
*Disable Enable
*Disable Enable
*Disable Enable
*Disable End Programming Format Editing Format 5 6.1.2 EXCLUSIVE DATA EDITING By default, only barcodes found meeting with the criteria are processed by the editing formats. Those found not meeting with the criteria are processed normally. When Exclusive Data Editing is enabled, all barcodes read by the scanner must be processed by the editing formats. If data is found excluded from all enabled editing formats (= not meeting with the specified criteria), the scanner will not accept the reading, and therefore, data will not be transmitted. Chapter 6 Applying Formats for Data Editing Enable
*Disable Yes
*No 219 Update 1662/1664 Barcode Scanner User Guide 6.2 HOW TO CONFIGURE EDITING FORMATS 220 End Programming Format Chapter 6 Applying Formats for Data Editing 6.2.1 SELECT FORMAT TO CONFIGURE Start Programming Format Select one editing format (Format 1~5) and the parameters pertaining to the editing format can then be configured applicable code type, data length, matching string & location, start position, field adjustment, total number of fields, field settings (field-dividing rule), additional fields, and field transmission sequence. Up to five different formats can be specified. Configure Format 1 Configure Format 2 Configure Format 3 Configure Format 4 Configure Format 5 221 Update Note: Before completing the programming of an editing format, if any barcode for parameters other than those pertaining to the editing format is read, the programming process will be automatically aborted. End Programming Format After having configured all the desired parameters, you must read the End Programming Format barcode, which can be located at the bottom of every even page in this chapter. End Programming Format 1662/1664 Barcode Scanner User Guide 6.2.2 RESTORE DEFAULT FORMAT You may select an existing editing format and have the defaults restored. The default settings of an editing format are listed below. Editing format Applicable Code Type Data Length Matching String Matching String Location Start Position Field Adjustment Total Number of Fields Additional Fields Field Transmission Sequence Field Setting field-dividing rule Not configured 0 (No qualification) Defaults All Disable None 1 None F1 From head No adjustment Restore Default Format 222 End Programming Format Chapter 6 Applying Formats for Data Editing 6.3 CONFIGURE FORMAT DEFINE DATA CRITERIA Three applicable conditions can be configured to check whether the data read by the scanner can be processed by the particular editing format. Note: Data editing cannot be performed unless the three conditions are all met. 6.3.1 APPLICABLE CODE TYPE By default, barcodes of all the supported symbologies will be processed by any editing format, if having been configured and enabled. For quick configuration, you may first clear all, and then select the desired symbologies. Note: You must have at least one symbology selected.
*Apply to All Clear All 223 Update 1662/1664 Barcode Scanner User Guide Editing Format for Codabar Editing Format for Code 39 Editing Format for Trioptic Code 39 Editing Format for Code 93 Editing Format for Code 128 224
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply End Programming Format Chapter 6 Applying Formats for Data Editing Editing Format for GS1-128 & GS1 DataBar Editing Format for ISBT 128 Editing Format for EAN-8 Editing Format for EAN-8 Addon 2 Editing Format for EAN-8 Addon 5
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply Update 225 1662/1664 Barcode Scanner User Guide Editing Format for EAN-13 Editing Format for EAN-13 Addon 2 Editing Format for EAN-13 Addon 5 Editing Format for Italian Pharmacode Editing Format for Industrial 25 226
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply End Programming Format Editing Format for Interleaved 25 Editing Format for Matrix 25 Editing Format for Chinese 25 Editing Format for MSI Editing Format for UPC-A Chapter 6 Applying Formats for Data Editing
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply Update 227 1662/1664 Barcode Scanner User Guide Editing Format for UPC-A Addon 2 Editing Format for UPC-A Addon 5 Editing Format for UPC-E Editing Format for UPC-E Addon 2 Editing Format for UPC-E Addon 5 228
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply End Programming Format Chapter 6 Applying Formats for Data Editing Editing Format for UCC Coupon Extended Code Editing Format for Code 11 Editing Format for Composite CC-A/B Editing Format for Composite CC-C Editing Format for Composite TLC-39
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply Update 229 1662/1664 Barcode Scanner User Guide Editing Format for US Postnet Editing Format for US Planet Editing Format for UK Postal Editing Format for Japan Postal Editing Format for Australian Postal 230
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply End Programming Format Chapter 6 Applying Formats for Data Editing Editing Format for Dutch Postal Editing Format for USPS 4CB/One Code/Intelligent Mail Editing Format for UPU FICS Postal Editing Format for PDF417 Editing Format for MicroPDF417
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply Update 231 1662/1664 Barcode Scanner User Guide Editing Format for Data Matrix Editing Format for Maxicode Editing Format for QR Code Editing Format for MicroQR Editing Format for Aztec 232
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply
*Apply Do Not Apply End Programming Format Chapter 6 Applying Formats for Data Editing 6.3.2 DATA LENGTH The length must include prefix, suffix (0x0d by default), length code, etc. By default, barcodes of any length (character count) are eligible for data editing. A value from 0 to 254 can be specified. When zero is given to both, the scanner will not perform the length qualification. 1) Read the barcode below to specify Max. Length or Min. Length separately, and follow steps 2~3. Max. Length Min. Length 2) Read the Decimal Value barcode on page 271 for the desired length. 3) Read the Validate barcode on the same page to complete this setting. 233 Update 1662/1664 Barcode Scanner User Guide 6.3.3 MATCHING STRING & LOCATION By default, no matching string is specified, and therefore, it is disabled. You may enable this feature by specifying a matching string; up to four characters are allowed. When the Matching String Location is zero, the scanner will only check for the existence of the matching string in the barcode data. Specify a value from 1 to 254 to indicate where the matching string starts in the barcode data. 4) Read the barcode to specify a matching string. Matching String 5) Read the Hexadecimal Value barcode on page 272 for the desired character string. 6) Read the Validate barcode to complete this setting. 7) Read the barcode to specify the location of the matching string. Location of Matching String 8) Read the Decimal Value barcode on page 271 for the desired location. 9) Read the Validate barcode on the same page to complete this setting. 234 End Programming Format Chapter 6 Applying Formats for Data Editing 6.4 CONFIGURE FORMAT DEFINE DATA FIELD Data can be divided into fields in one of the following direction 6.4.1 START POSITION from head (F1) to tail (F5) from tail (F1) to head (F5) 6.4.2 FIELD ADJUSTMENT You may apply equal length to all fields, if necessary. If data is found longer than specified, it will be truncated automatically. When data is found shorter, it will add Space (0x20) to field.
*From Head From Tail
*No adjustment Set length to adjust fields (*0) 1) Read the barcode above to adjust field by length. 2) Read the Decimal Value barcode on page 271 for the desired field length. 3) Read the Validate barcode on the same page to complete this setting. 235 Update 236 1662/1664 Barcode Scanner User Guide 6.4.3 TOTAL NUMBER OF FIELDS Data can be divided into at most 6 fields; each of them is numbered from F1 to F6 accordingly. However, only F1~F5 can be configured. The total number of fields must be specified correctly. If three fields are configured for the editing format, the data characters after F3 will be assigned to F4 automatically. This feature is quite useful especially when data of variable lengths is processed by editing formats.
*One Field Two Fields Three Fields Four Fields Five Fields Six Fields End Programming Format Note: The number of configurable fields is always one less than the total number of fields specified. The extra data characters beyond the last field configured will be automatically assigned to the next field. Chapter 6 Applying Formats for Data Editing Data eligible for editing formats is divided into fields by user-specified rules either using the field terminating string or specified field length. Specify the field terminating string. Up to two characters are allowed. The scanner will search for the occurrence of this particular string in the data. By default, this string will be included in the field. You may discard it. Alternatively, you may simply specify the field length. The scanner will assign the next specified number of characters into the field. 6.4.4 FIELD SETTINGS By Terminating String By Length Field 1 Setting 1) Read the barcode below to divide field 1 by a specified terminating string. 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. 3) Read the Validate barcode to complete this setting. 4) Read the Discard Separator barcode if the field separator is not desired in the field. Select Field Separator to Divide Field 1
*Include Separator Discard Separator Update 237 If not dividing the field by a specific separator, you may divide it by a specified length. 1) Read the barcode below to divide field 1 by length. Divide Field 1 by Length 2) Read the Decimal Value barcode on page 271 for the desired field length. 3) Read the Validate barcode on the same page to complete this setting. 1662/1664 Barcode Scanner User Guide Field 2 Setting 1) Read the barcode below to divide field 2 by a specified terminating string. 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. 3) Read the Validate barcode to complete this setting. 4) Read the Discard Separator barcode if the field separator is not desired in the field. Select Field Separator to Divide Field 2
*Include Separator Discard Separator Divide Field 2 by Length If not dividing the field by a specific separator, you may divide it by a specified length. 1) Read the barcode below to divide field 2 by length. 2) Read the Decimal Value barcode on page 271 for the desired field length. 3) Read the Validate barcode on the same page to complete this setting. 238 End Programming Format Chapter 6 Applying Formats for Data Editing Field 3 Setting 1) Read the barcode below to divide field 3 by a specified terminating string. 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. 3) Read the Validate barcode to complete this setting. 4) Read the Discard Separator barcode if the field separator is not desired in the field. Select Field Separator to Divide Field 3
*Include Separator Discard Separator Divide Field 3 by Length If not dividing the field by a specific separator, you may divide it by a specified length. 1) Read the barcode below to divide field 3 by length. 2) Read the Decimal Value barcode on page 271 for the desired field length. 3) Read the Validate barcode on the same page to complete this setting. 239 Update 1662/1664 Barcode Scanner User Guide Field 4 Setting 1) Read the barcode below to divide field 4 by a specified terminating string. 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. 3) Read the Validate barcode to complete this setting. 4) Read the Discard Separator barcode if the field separator is not desired in the field. Select Field Separator to Divide Field 4
*Include Separator Discard Separator Divide Field 4 by Length If not dividing the field by a specific separator, you may divide it by a specified length. 1) Read the barcode below to divide field 4 by length. 2) Read the Decimal Value barcode on page 271 for the desired field length. 3) Read the Validate barcode on the same page to complete this setting. 240 End Programming Format Chapter 6 Applying Formats for Data Editing Field 5 Setting 1) Read the barcode below to divide field 5 by a specified terminating string. 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. 3) Read the Validate barcode to complete this setting. 4) Read the Discard Separator barcode if the field separator is not desired in the field. Select Field Separator to Divide Field 5
*Include Separator Discard Separator Divide Field 5 by Length If not dividing the field by a specific separator, you may divide it by a specified length. 1) Read the barcode below to divide field 5 by length. 2) Read the Decimal Value barcode on page 271 for the desired field length. 3) Read the Validate barcode on the same page to complete this setting. 241 Update 1662/1664 Barcode Scanner User Guide Additional Fields Up to five additional fields can be created for each editing format; each of them is numbered from AF1 to AF5 accordingly. If Bluetooth HID or USB HID is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when Normal Key is selected for Key Type. Key Type Key Status Scan Code Up to 2 scan code values are allowed. N/A Normal Key Up to 4 character strings are allowed. Add Shift Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt Refer to Keyboard Wedge Table. 1) Read the barcode below to specif y an additional field, one at a time. Additional Field 1 Additional Field 2 Additional Field 3 Additional Field 4 Additional Field 5 2) Read the Hexadecimal Value ba rcode on page 272 for the desired additional field. 3) Read the Validate barcode to complete this setting. 242 End Programming Format Chapter 6 Applying Formats for Data Editing 6.4.5 PAUSE FIELD SETTING Pause Field Time You can limit the pause time interval (1~16). By default, it is set to 1 second. Pause Field Time 1~16 sec.
(*1) 1) Read the barcode above to specify the time interval for the Pause Field. (It is set to 1 by default.) 2) Read the Decimal Value barcode on page 271. For example, read 1 and 0 for setting the Pause Field Time to 10 seconds. 3) Read the Validate barcode on the same page to complete this setting. 243 Update 1662/1664 Barcode Scanner User Guide 6.5 CONFIGURE FORMAT DEFINE TRANSMISSION SEQUENCE After configuring the data fields and additional fields, you must now program the transmission sequence of these fields that comprise the final data. This field transmission sequence can be assigned in any desired order and fields can be assigned multiple times as well. Note: Up to twelve fields can be assigned. 1) Read the Start barcode to begin with programming the field transmission sequence. Start Programming 2) Program the transmission sequence by reading the desired fields as well as additional fields. Field 1 Field 2 Field 3 Field 4 Field 5 Field 6 Additional Field 1 244 End Programming Format 3) Read the End barcode to complete this setting. End Programming Chapter 6 Applying Formats for Data Editing Additional Field 2 Additional Field 3 Additional Field 4 Additional Field 5 Pause Field Null Character Field 245 Update 1662/1664 Barcode Scanner User Guide 6.6 PROGRAMMING EXAMPLES 6.6.1 EXAMPLE I Extract data from the 10th character to the 19th character... The editing format should be configured as follows:
Read the Enter Setup barcode to enter the Configuration Mode. Read the Configure Format 1 barcode. Read the Clear All and Code 128 barcodes for applicable code type. Read the Three Fields barcode. Read the Divide Field 1 by Length barcode, and set length to 9. Field 1 data starts from the 1st character to the 9th character. 6) Read the Divide Field 2 by Length barcode, and set length to 10. Field 2 data starts from the 10th character to the 19th character. Read the Start (Programming) barcode to program the transmission sequence. Read the Field 2 barcode. Read the End barcode to complete the transmission sequence setting. 10) Read the End Programming Format barcode to complete the setting of Editing Format 1. 11) Read the Enable Format 1 barcode to apply Editing Format 1 to Code 128. 12) Read the Update barcode to exit the Configuration Mode. 1) 2) 3) 4) 5) 7) 8) 9) 246 End Programming Format Chapter 6 Applying Formats for Data Editing 6.6.2 EXAMPLE II Extract the date code, item number, and quantity information from barcodes. Data in a barcode is encoded like this:
From the 1st character to the 6th character is the date code. From the 7th character to the dash - character is the item number. After the dash - character is the quantity information. Data will be transmitted like this:
The item number goes first, then a TAB character, followed by the date code, then another TAB character, and finally the quantity information. 1) 2) 3) 4) 6) 7) 8) 9) The editing format should be configured as follows:
Read the Enter Setup barcode to enter the Configuration Mode. Read the Configure Format 2 barcode. Read the Three Fields barcode. Read the Divide Field 1 by Length barcode, and set length to 6. Field 1 data starts from the 1st character to the 6th character. 5) Read the Select Field Separator to Divide Field 2 barcode, and use a dash - character. Field 2 data starts from the 7th character until the dash - character is met. Read the Additional Field 1 barcode, and use a tab character for the field. Read the Start (Programming) barcode to program the transmission sequence. Read the Field 2, Additional Field 1, Field 1, Additional Field 1, Field 3 barcodes. Read the End barcode to complete the transmission sequence (F2 A1 F1 A1 F3) setting. 10) Read the End Programming Format barcode to complete the setting of Editing Format 1. 11) Read the Enable Format 2 barcode to apply Editing Format 2 to all code types. 12) Read the Update barcode to exit the Configuration Mode. 247 Update 1662/1664 Barcode Scanner User Guide 248 End Programming Format SPECIFICATIONS Optical Characteristics Scan Engine Light Source RF Characteristics WPAN Module Coverage (line-of-sight) Interface Supported Physical Characteristics Memory Switch Indication Dimensions Weight 1662 1D Laser 1664 2D Imager Visible Laser Diode Visible Red LED Bluetooth Class 2 compliance 20 meters with 3610 Serial Port Profile (Bluetooth SPP) Human Interface Device Profile (Bluetooth HID) 3610 Direct USB HID Direct USB Virtual COM 10 KB for transmit buffer 4MB flash for memory mode Push-button switch for [Trigger] key, plus [Power/Delete] key Triple-color LED (Red/Green/Blue) and beeper 113 x 44.9 x 29.9 mm 106g (With Battery) 83g (Without Battery) 249 Update Battery Rechargeable Li-ion battery 3.7 V, 850 mAh 1662/1664 Barcode Scanner User Guide Electrical Characteristics Power Adaptor Input Output AC 100~240 V (50/60 Hz) DC 5V 2A (Battery Charger) Operating Temperature 0 C to 40 C Environmental Characteristics Temperature Operating 0 C to 50 C Storage
-20 C to 60 C Humidity
(Non-condensing) Operating 10% to 90%
Storage 5% to 95%
Electrostatic Discharge 15 kV air discharge, 8 kV contact discharge Firmware upgradeable Download firmware updates via the download utility. Use setup barcodes or host serial commands. Windows-based ScanMaster Resistance Programming Support Configuration Software Accessories ( means supported) CipherLab Dongle(3610) Rechargeable Li-ion Battery Direct USB Cable Wristband Protective Cover (Pouch) Single Battery Charger 250 Enter Setup FIRMWARE UPGRADE Appendix I Upgrade firmware to one scanner at a time. For example, turn off each of the rest scanners when there is more than one scanner connected to host computer. Note: In case it fails downloading due to low battery, make sure the targe scanner is loaded with a good battery and the battery charge is enough. When the scanner tries to enter the download mode and detects low battery charge remaining, you will hear one short beep then one long beep (high-low tone) accompanied by the red LED indicator flashing five times. Then the upgrade task is aborted. In order to avoid data loss during firmware upgrade. Please save or upload all the data from the flash memory before beginning firmware upgrade. HOW TO UPGRADE 1662/1664 FIRMWARE USING 3610 1) Connect 3610 to the USB port of PC after installing its driver. 2) Refer to 3.1.1 Connect to 3610 for connecting to 3610. Read the Set Connection label first, and then the Serial Number label. Both labels can be located at the back of 3610. 3) Read the following barcodes in sequence to configure the scanner to use USB Virtual COM as the download interface. Enter Setup 10 USB Activate 36 COM Virtual e Updat Update Note: For 1662/1664, also choose to use Direct USB Virtual COM interface. 4) Read the following barcodes in sequence for the scanner to enter download mode. The scanner will respond with beeps to indicate it is ready for downloading. 251 1662/1664 Barcode Scanner User Guide Enter Setup Download 5) Run the download utility ProgLoad.exe on your computer. Kernel Program K1664_V*.shx User Program STD1664_V*.shx For the communication settings, select RS-
232 and the correct COM port for USB Virtual COM interface. Ignore the baud rate setting. For the file option, click [Browse] to select the target file for firmware update. Click [OK]. 6) After upgrading kernel, you will need to manually restart the scanner. After upgrading the user program, the scanner will automatically restart itself once the download is completed successfully. Note: The output interface remains unchanged as specified in step 3 (= USB Virtual COM). 252 Enter Setup Appendix I Firmware Upgrade USE DIRECT USB VIRTUAL COM 1) Use the provided USB cable to connect 1662/1664 to the USB port of PC. You will need to install its driver first!
2) Read the following barcodes in sequence to configure 1662/1664 to use Direct USB Virtual COM as the download interface (read either barcode label 100008 or 100010). Enter Setup Or Activate Direct USB Virtual COM Activate Direct USB Virtual COM_CDC Update w nload Do Enter Setup 3) And then read the following barcodes in sequence for the scanner to enter download mode. The scanner will respond with beeps to indicate it is ready for downloading. 4) Run the download utility ProgLoad.exe on host computer. Kernel Program K1664_V*.shx User Program STD1664_V*.shx 253 Update 1662/1664 Barcode Scanner User Guide For the communication settings, select RS-
232 and the correct COM port for Direct USB Virtual COM interface. Ignore the baud rate setting. For the file option, click [Browse] to select the target file for firmware update. Click [OK]. 5) After upgrading kernel, you will need to restart the scanner manually. After upgrading the user program, the scanner will restart itself automatically once the download is completely. Note: Because 1662/1664 supports the downloading of firmware via Direct USB Virtual COM interface, the output interface will be set to the previously used one upon completion of firmware upgrade. USE BLUETOOTH DONGLE request from your computer. SPP as download interface. 1) Refer to 3.2.3 Connect to Dongle for the target scanner to accept the connection 2) Read the following barcodes in sequence to configure the scanner to use Bluetooth Enter Setup etooth Activate Blu SPP Update 254 Enter Setup 3) Read the following barcodes in sequence for the scanner to enter the download mode. The scanner will respond with beeps to indicate it is ready for downloading. Appendix I Firmware Upgrade Enter Setup load Down 4) Run the download utility ProgLoad.exe on your computer. Kernel Program K1664_V*.shx User Program STD1664_V*.shx the correct COM port For the communication settings, select RS-
for 232 and Bluetooth SPP interface. Ignore the baud rate setting. For the file option, click [Browse] to select the target file for firmware update. Click [OK]. 5) After upgrading kernel, you will need to manually restart the scanner. After upgrading the user program, the scanner will automatically restart itself once the download is completed successfully. Note: The output interface remains unchanged as specified in step 2 (=Bluetooth SPP). 255 Update 1662/1664 Barcode Scanner User Guide HOW TO UPGRADE 3610 FIRMWARE Connect 3610 to the USB port of PC after installing its driver. Refer to 3.1.1 Connect to 3610 for the target scanner to connect to 3610. Note: While upgrading 3610 firmware, the system automatically uses the VCOM_CDC driver if the current connection interface is HID. Make sure the VCOM_CDC driver has been installed on your computer (for firmware 2.0 or later). UPGRADE 3610 CPU FIRMWARE 1) Read the following barcodes in sequence for 3610 to enter the download mode. The Communication LED on 3610 will be flashing red to indicate it is ready for downloading. Enter Setup Download 3610 CPU Firmware 2) Run the download utility ProgLoad.exe on your computer. Kernel Program K3610_V*.shx User Program STD3610_V*.shx For the communication settings, select RS-
232 and the correct COM port for USB Virtual COM interface. Ignore the baud rate setting. For the file option, click [Browse] to select the target file for firmware update. Click [OK]. 256 Enter Setup Appendix I Firmware Upgrade 3) The 3610 will automatically restart itself when upgrading firmware is completed successfully. configuration mode). 4) Read the Update barcode for the scanner to resume its operation (exit the Update UPGRADE 3610 USB BRIDGE FIRMWARE Note: Upgrade USB bridge firmware only for elder firmware versions. Theres no need for 3610 firmware version 2.0 or later to upgrade USB bridge firmware. 1) Read the following barcodes in sequence for 3610 to enter the download mode. The Communication LED on 3610 will be flashing red to indicate it is ready for downloading. Enter Setup Download 3610 USB Bridge Firmware 2) Run the download utility ProgLoad.exe on your computer. Kernel Program User Program K3610Bridge_V*.shx STD3610Bridge_V*.shx 257 Update 1662/1664 Barcode Scanner User Guide For the communication settings, select RS-
232 and the correct COM port for USB Virtual COM interface. Ignore the baud rate setting. For the file option, click [Browse] to select the target file for firmware update. Click [OK]. 3) The 3610 will automatically restart itself when upgrading firmware is completed successfully. configuration mode). 4) Read the Update barcode for the scanner to resume its operation (exit the Update 258 Enter Setup HOST SERIAL COMMANDS Appendix II SERIAL COMMANDS D E Purpose To disable the scanner. Remarks D Purpose To enable the scanner. Remarks E
#@nnnnnn<CR>
save the settings.
#@ - - - -<CR>
Purpose To halt the scanner.
#@ . <CR>
Purpose To resume operation.
#@////<CR >
Purpose To respond with a beep. Purpose To configure the scanner. Remarks nnnnnn the six digits of command parameters. For example, 109952 is to list the current Code ID settings. List Page 3 0x23 + 0x40 + 0x31 + 0x30 + 0x39 + 0x39 + 0x35 + 0x32 + 0x0d Serial Command Note: After configuring the scanner, you may send the serial command #@109999 to Remarks 0x23 + 0x40 + 0x2d + 0x2d + 0x2d + 0x2d + 0x0d Remarks 0x23 + 0x40 + 0x2e + 0x2e + 0x2e + 0x2e + 0x0d Remarks 0x23 + 0x40 + 0x2f + 0x2f + 0x2f + 0x2f + 0x0d 259 Update 1662/1664 Barcode Scanner User Guide
#@TRIGOFF<CR>
Purpose To disable the software trigger Remarks 0x23 + 0x40 + 0x54 + 0x52 + 0x49 + 0x47 + 0x4f + 0x46 +
0x46 + 0x0d
#@TRIGON<CR>
Purpose To enable the software trigger Remarks 0x23 + 0x40 + 0x54 + 0x52 + 0x49 + 0x47 + 0x4f + 0x4e +
0x0d
#@RDSN<CR>
Purpose To read serial number
#@BEEP,nn<CR>
Remarks 0x23 + 0x40 + 0x52 + 0x44 + 0x53 + 0x4E + 0x0D Purpose Have the scanner beep as many times as you specified ranging from 00 to 99 times (00 is to stop the work). The length of beep time is based on the duration of Good Read Beep setting and the constant interval between two beeps is 100ms. Remarks nn the two digits of command parameters For example, #@BEEP,09 is to have the scanner beep for 9 times. 0x23 + 0x40 + 0x42 + 0x45 + 0x45 + 0x50 + 0x2c + 0x30
+ 0x39 + 0x0d
#@RLED,nn<CR>
Purpose Have the scanners red LED indicator blink as many times as you specified ranging from 00 to 99 (00 is to stop the work). The length of blinking time is based on the Good Read LED Duration setting and the constant interval between two flashes is 200ms. Remarks nn the two digits of command parameters For example, #@RLED,09 is to have the scanner blink for 9 times. 0x23 + 0x40 + 0x52 + 0x4c + 0x45 + 0x44 + 0x2c + 0x30
+ 0x39 + 0x0d
#@GLED,nn<CR>
Purpose Have the scanners green LED indicator blink as many times as you specified ranging from 00 to 99 (00 is to stop the work). The length of blinking time is based on the Good Read LED Duration setting and the constant interval between two flashes is 200ms. Remarks nn the two digits of command parameters 260 Enter Setup Appendix II Host Serial Commands For example, #@GLED,09 is to have the scanner blink for 9 times. 0x23 + 0x40 + 0x47 + 0x4c + 0x45 + 0x44 + 0x2c + 0x30
+ 0x39 + 0x0d
#@VIBR,nn<CR>
Purpose Have the scanner vibrate as many times as you specified ranging from 00 to 99
(00 is to stop the work). The length of vibrating time is based on the Good Read Vibrator Duration setting and the constant interval between two shakes is 500ms. Remarks nn the two digits of command parameters For example, #@VIBR,09 is to have the scanner blink for 9 times. 0x23 + 0x40 + 0x56 + 0x49 + 0x42 + 0x52 + 0x2c + 0x30
+ 0x39 + 0x0d
#@RDBATCAP<CR>
Purpose Get battery capacity information. Remarks 0x23 + 0x40 + 0x52 + 0x44 + 0x42 + 0x41 + 0x54 + 0x43
+ 0x41 + 0x50 + 0x0d EXAMPLE You may run HyperTerminal.exe on the host computer to send serial commands to the scanner via USB Virtual COM or Bluetooth SPP. For the scanner to stop immediately For the scanner to resume working For the scanner to change the beeper to medium volume and beep For the scanner to change the beeper to minimal volume and beep For the scanner to change the beeper frequency to 8 kHz (for Good Read Beep only) D E
#@101011<CR>
#@////<CR>
#@101010<CR>
#@////<CR>
and beep
#@101001<CR>
#@////<CR>
and beep
#@101008<CR>
For the scanner to change the beeper length to longest (for Good Read Beep only) 261 Update For the scanner to save the settings, send the serial command #@109999 1662/1664 Barcode Scanner User Guide
#@////<CR>
#@101011<CR>
#@109999<CR>
#@RDSN<CR>
#@////<CR>
#@BEEP,09<CR>
#@RLED,09<CR>
#@GLED,09<CR>
#@VIBR,09<CR>
For the scanner to read the serial number and beep -
For the scanner to beep for nine times -
For the scanners LED indicator to blink in red for nine times -
For the scanners LED indicator to blink in green for nine times -
For the scanner to shake for nine times -
Get the battery capacity information -
#@RDBATCAP<CR>
Note: (1) For USB Virtual COM, only configure the first scanner that connects to 3610. To identify the scanner, send the serial command to have it respond with a beep.
(2) For Bluetooth SPP, allows configuring up to seven scanners at the same time. 262 Enter Setup Appendix II Host Serial Commands 3610 SETUP BARCODES & SERIAL COMMANDS Normally, configure the 3610 dongle by having a connected scanner read 3610-related setup barcodes. 1) Connect 3610 to the USB port of PC. You will need to install its driver first!
2) Refer to 3.1.1 Connect to 3610 for the target scanner to connect to 3610. Read the Set Connection label first, and then the Serial Number label. Both labels can be located at the back of 3610. 3) Read the following barcodes in sequence to configure 3610. Enter Setup Update
(3610-related setup barcodes) For 3610-related setup barcodes, refer to the Setup Barcodes list below. Note that for the Version and GetID barcodes, you must run HyperTerminal.exe or any text editor to receive or view the information. If the output interface is USB Virtual COM, run HyperTerminal.exe on the host computer to receive the information. If the output interface is USB HID, run any text editor to receive the information. 263 Update 1662/1664 Barcode Scanner User Guide 3610 SERIAL COMMANDS AND EQUIVALENT SETUP BARCODES Config<CR>
Purpose To configure 3610. Here is the setup barcode for this serial command:
Remarks A list of the current settings will be displayed. Run HyperTerminal.exe on your computer and change the settings one by one. Config DefaultSetting<CR>
Purpose To restore the default settings. Here is the setup barcode for this serial command:
DefaultSetting SingleConnection<CR>
Purpose To allow only one scanner connecting to 3610. Here is the setup barcode for this serial command:
SingleConnection MultiConnection<CR>
Purpose To allow up to seven scanners connecting to 3610. Here is the setup barcode for this serial command:
MultiConnection UseOnePortforAll<CR>
Purpose To use one Virtual COM port for all whenever connecting 3610 to PC via USB. This setting requires to connect one 3610 at a time, and will facilitate configuring multiple 3610 via the same Virtual COM port (for administrators or factory use). Here is the setup barcode for this serial command:
UseOnePortforAll 264 Enter Setup Appendix II Host Serial Commands UseVariablePort<CR>
Purpose To use variable Virtual COM port when connecting more than one 3610 to PC via USB. Here is the setup barcode for this serial command:
UseVariablePort Version<CR>
Purpose To get the firmware versions (CPU+USB Bridge). Here is the setup barcode for this serial command:
Version GetID<CR>
Purpose To get MAC ID. Here is the setup barcode for this serial command:
GetID Download<CR>
Purpose To download CPU firmware to 3610. Here is the setup barcode for this serial command:
Download LoadBridge<CR>
Purpose To download USB Bridge firmware to 3610. Here is the setup barcode for this serial command:
LoadBridge 265 Update 1662/1664 Barcode Scanner User Guide EXAMPLE Without using the scanner to read the above setup barcodes for configuring the 3610 dongle, run HyperTerminal.exe on the host computer to send serial commands to 3610 via USB Virtual COM. 1) Connect 3610 to the USB port of PC. 2) The Communication LED will indicate when 3610 can accept serial commands after initializing. Refer to the table below. If the output interface is USB Virtual COM, run HyperTerminal.exe on the host computer. While the Communication LED on 3610 is purple (red with flashing blue), type the serial command within 3 seconds. If the output interface is USB HID, press the Num Lock or Caps Lock key via the keyboard 5 times within 3 seconds while the Communication LED on 3610 is flashing red and blue. This will change the interface from USB HID to USB Virtual COM and the Communication LED will become purple (red with flashing blue). Then, run HyperTerminal.exe on the host computer. While the Communication LED on 3610 is purple (red with flashing blue), type the serial command within 3 seconds. After configuring via serial commands, the interface will reset to USB HID after re-
connecting 3610. Communication LED Meaning Blue, solid Initialize
Red, solid Blue, flashing Serial command mode with USB Virtual COM: wait 3 seconds for starting a serial command Red, flashing Blue, flashing Serial command mode with USB HID changed to USB Virtual COM first: wait 3 seconds for pressing [Num Lock] or [Caps Lock] 5 times via keyboard The serial commands mentioned above have to be typed within 3 seconds. However, the commands below can be typed freely without any time limit. Purpose To list the scanner devices connecting with 3610
#$ShowScanner<CR>
#$SelectScannerN<CR>
Purpose To select a scanner device from the list for configuring Remarks N the scanner ID in numerals representing the scanner device in the list 266 Enter Setup Appendix III KEYBOARD WEDGE TABLE 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 INS DLT Home End Up Down Left BS HT LF 1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Right ESC PgUp Exec CR CR*
PgDn F1 2 SP
3 0 1 2 3 4 5 6 7 8 9
4
A B C D E F G H I J K L M N O 5 P Q R S T U V W X Y Z
_ 6
a b c d e f g h i j k l m n o 7 p q r s t u v w x y z
8
Dly ENTER*
Note: (1) ~: Digits of numeric keypad.
(2) CR*/ENTER*: ENTER key on the numeric keypad. 267 Update 1662/1664 Barcode Scanner User Guide KEY TYPE & STATUS KEY TYPE If Bluetooth HID or USB HID is configured for interface, Key Type and Key Status will then become applicable. KEY STATUS Decide whether or not to change key status when Normal Key is selected for Key Type.
*Normal Scan Code Add Shift Add Left Ctrl Add Right Ctrl Add Left Alt Add Right Alt 268 Enter Setup Appendix III Keyboard Wedge Table EXAMPLE KEY TYPE = NORMAL For example, if you want to program the character ! as the prefix code:
Read the Configure Prefix barcode. Read the Hexadecimal Value barcode on page 272 for 2 and 1. Read the Validate barcode to complete this setting. KEY TYPE = SCAN CODE For example, if you want to program the character a (= 1C on the scan code table) as the prefix code:
Read the Configure Prefix barcode. Read the Scan Code barcode. Read the Hexadecimal Value barcode on page 272 for 1 and C. Read the Validate barcode to complete this setting. KEY TYPE = NORMAL + KEY STATUS = SHIFT For example, if you want to program the character ! (= Shift + 1 on keyboard) as the prefix code:
Read the Configure Prefix barcode. Read the Add Shift barcode. Read the Hexadecimal Value barcode on page 272 for 3 and 1. Read the Validate barcode to complete this setting. KEY TYPE = NORMAL + KEY STATUS = CTRL For example, if you want to program Ctrl+A and Ctrl+$ as the prefix code:
Read the Configure Prefix barcode. Read the Add Left Ctrl barcode. Read the Hexadecimal Value barcode on page 272 for 4, 1 (= A). Read the Add Left Ctrl barcode. Read the Hexadecimal Value barcode on page 272 for 2, 4 (= $). Read the Validate barcode to complete this setting. 1) 2) 3) 1) 2) 3) 4) 1) 2) 3) 4) 1) 2) 3) 4) 5) 6) 269 Update 1662/1664 Barcode Scanner User Guide 270 Enter Setup NUMERAL SYSTEMS DECIMAL SYSTEM Decimal Appendix IV 0 2 4 6 8 1 3 5 7 9 Validate the Values Validate Update Abort 271 1662/1664 Barcode Scanner User Guide HEXADECIMAL SYSTEM Hexadecimal 272 0 2 4 6 8 A C E 1 3 5 7 9 B D F Enter Setup Appendix IV Numeral Systems Validate the Values Validate ASCII TABLE 0 SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI 1 DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 2 SP
3 0 1 2 3 4 5 6 7 8 9
4
A B C D E F G H I J K L M N O 5 P Q R S T U V X Y Z
_ W 6
a b c d e f g h i j k l m n o 7 p q r s t u v w x y z
DEL 0 1 2 3 4 5 6 7 8 9 A B C D E F Update Abort 273 1662/1664 Barcode Scanner User Guide ENTERING PIN CODE FOR AUTHENTICATION USE PRESET PIN authentication. 1) In the configuration mode, read the barcode below to use a preset PIN for 2) Read one of the barcodes to specify the PIN code, in decimal or hexadecimal. By default, the PIN code is set to 0000. Maximum 16 characters are allowed. Use Preset PIN Enter PIN in Hexadecimal Enter PIN in Decimal Clear PIN Code 3) Read the Decimal Value barcode on page 271 or the Hexadecimal Value barcode on page 272 for the desired digits or character string. Read the Clear PIN Code barcode first if you need to re-input the PIN code. 4) Read the Validate barcode to complete this setting. 274 Enter Setup Appendix IV Numeral Systems DISABLE AUTHENTICATION OR USE RANDOM PIN In the configuration mode, read the barcode below to disable authentication (= No PIN) or use a random PIN for authentication.
*No PIN or use random PIN Note: When using Bluetooth HID, some device drivers may not support pre-defined PIN code for authentication. In this case, make sure you have the scanner set to No PIN or use random PIN before pairing. While pairing, the host PIN code will be displayed on the computer screen. Use Random PIN When the target device is set to use a random PIN for authentication, wait until the random PIN is displayed on the target device while pairing, and then input the matching PIN code on the scanner. Note: Follow the steps below to enter the matching PIN on the scanner. There is no need to enter the configuration mode!
1) Read one of the barcodes to spe cify the PIN code, in decimal or hexadecimal. Enter PIN in Hexadecimal Enter PIN in Decimal 2) Read the Decimal Value barco 272 for the desired digits or cha de on page 271 or the Hexadecimal Value barcode on page racter string. Read the Clear PIN Code barc ode first if you need to re-input the PIN. Clear PIN Code Update Abort 275 1662/1664 Barcode Scanner User Guide 3) Read the Validate barcode to complete this setting. Reject Random PIN Request When the random PIN is displayed on the target device while pairing, you can reject the PIN request by having the scanner read the Validate barcode. 276 Enter Setup SET UP DRIVER LICENSE (1664 ONLY) Appendix V 1664 has the capable of reading 2D drivers licenses and other American Association of Motor Vehicle Administrators (AAMVA) compliant ID cards. For compliant 2D licensed card scanning, it can decode the information embedded in the ID cards to a formatted data. Combine with ScanMaster utility, it also supports user an arranged and easy-to-use interface. Note: The configured settings will be saved into the Flash memory and applied when using next time. LICENSE PARSING
*Parse Disable Parse Enable Parse Field Clear
*Enable Disable FILE TYPE You can check the file type of ANSI by scanning the barcode as below. Update Abort 277 1662/1664 Barcode Scanner User Guide LICENSE DATA 1664 allows you to arrange the sequences of license embedded data via separators and fields. In order to present data in a consistent format, some barcodes (ex. First Name, Middle Name/Initial, Last Name, Name suffix, Name Prefix, Birth Date and so on) will return data based on the calculated actual data contained in the ID bar code. Full Name Last Name First Name Middle Name/Initial Name Suffix Name Prefix Mailing Address Line1 Mailing Address Line2 Mailing Address City Mailing Address State 278 Enter Setup Appendix V Set up Driver License (1664 only) Mailing Address Postal Code Home Address Line1 Home Address Line2 Home Address City Home Address State Home Address Postal Code License ID Number License Class License Restrictions License Endorsements Height
(Feet and/or Inches) Height
(Centimeters) Update Abort 279 1662/1664 Barcode Scanner User Guide Weight
(Pounds) Weight
(Kilograms) Eye Color Hair Color Birth Date Gender License Expiration Date License Issue Date Issue Timestamp Number of Duplicates Medical Codes Organ Donor 280 Enter Setup Appendix V Set up Driver License (1664 only) Nonresident Customer ID Social Security Number AKA Birth Date AKA Social Security Name AKA Full Name AKA Last Name AKA First Name AKA Middle Name/Initial AKA Name Suffix AKA Name Prefix Weight Range Update Abort 281 1662/1664 Barcode Scanner User Guide Document Discriminator Country Federal Commission Codes Place of Birth Audit Information Inventory Control Race/Ethnicity Std Vehicle Class Std Restrictions Std Endorsements Class Description Endorsement Description 282 Enter Setup Appendix V Set up Driver License (1664 only) Restrictions Description Permit Class Permit Expiration Date Permit ID Number Permit Issue Date Permit Restrictions Permit Endorsements Issuer ID Number Family Name Truncation First Name Truncation Middle Name Truncation Update Abort 283 1662/1664 Barcode Scanner User Guide SEPARATORS AND FIELDS You can define the separators to separate Fields during the transmission sequence of data scanning. In addition to the built-in data elements, you can also specify up to 5 Additional Fields with 4 bytes characters. Program the transmission sequence by reading the desired fields as additional fields. Note: Up to 5 separators can be assigned. 284 Separator 1
(1 byte)
*Space Separator 2
(1 byte)
*Enter Separator 3
(1 byte)
*, Separator 4
(1 byte)
*. Separator 5
(1 byte)
Additional Field 1
(4 bytes) Additional Field 2
(4 bytes) Additional Field 3
(4 bytes) Additional Field 4
(4 bytes) Additional Field 5
(4 bytes) Enter Setup Appendix V Set up Driver License (1664 only) EDIT SEPARATORS All of the driver license fields can be split with a pre-selected separator, for example, -
as First Name-Last Name or : as First Name:Last Name. Edit Separator 1 Edit Separator 2 Edit Separator 3 Edit Separator 4 Edit Separator 5 1) Read the barcode above to apply separator to driver license information separately, and follow steps 2~3. 2) Read the Hexadecimal Value barcode on page 272 for the desired character string. For example, read 3 and A for the separator to split the data with character [:]. 3) Read the Validate barcode on the same page to complete this setting. Update Abort 285 1662/1664 Barcode Scanner User Guide EDIT FIELDS Up to five additional fields can be created for each editing format; each of them is numbered from Additional 1 to Additional 5 accordingly. If Bluetooth HID or USB HID is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when Normal Key is selected for Key Type. Key Type Key Status Scan Code Up to 2 scan code values are allowed. N/A Normal Key Up to 4 character strings are allowed. Add Shift Add Left Ctrl Add Left Alt Add Right Ctrl Add Right Alt Refer to Keyboard Wedge Table. Edit Additional Field 1 Edit Additional Field 2 Edit Additional Field 3 Edit Additional Field 4 Edit Additional Field 5 1) Read the barcode above to specify an additional field, one at a time. 2) Read the Hexadecimal Value barcode on page 272 for the desired additional field. 3) Read the Validate barcode on the same page to complete this setting. 286 Enter Setup Appendix VI Keyboard Type One-Scan Barcode Appendix VI KEYBOARD TYPE ONE-SCAN BARCODE REMOTE USB HID (VIA 3610) PCAT (US) PCAT (German) PCAT (Swedish) PCAT (UK) PCAT (French) PCAT (Italian) PCAT (Norwegian) PCAT (Belgium) Update Abort 287 1662/1664 Barcode Scanner User Guide PCAT (Spanish) PCAT (Portuguese) User-defined table PCAT (Hungarian) PCAT (Danish) 288 PS55 A01-2 (Japanese) PCAT (Turkish) PCAT (Swiss German) Enter Setup BLUETOOTH HID Appendix VI Keyboard Type One-Scan Barcode PCAT (French) PCAT (Italian) PCAT (Norwegian) PCAT (Belgium) PCAT (US) PCAT (German) PCAT (Swedish) PCAT (UK) PCAT (Spanish) Update Abort 289 1662/1664 Barcode Scanner User Guide PCAT (Portuguese) User-defined table PCAT (Hungarian) PCAT (Danish) PCAT (Brazilian Portuguese) 290 PS55 A01-2 (Japanese) PCAT (Turkish) PCAT (Swiss German) PCAT (Dutch) Enter Setup
1 | ID Label/Location Info revised0629 | ID Label/Location Info | 152.36 KiB | June 29 2021 |
BT Barcode Scanner esta res) Model (##2!):1662 A IC: 5121A-1664A FCC ID: Q3N-1664A pe 50 _,,,,, Sole fer" LAB]
mance: K NEE BT Barcode Scanner CSE EE) Model(##2):1664 A omy PAT CLL LN FCC ID: Q3N-1664A
(Cee INPUT(#A)
1 | Confidentiality | Cover Letter(s) | 43.95 KiB | June 28 2021 / June 29 2021 |
FCC, Request for non-disclosure RF_501, Issue 7 Date: 19-Oct-10 Page 1 of 1 Company Name: CIPHERLAB CO., LTD. Address:
City:
Country:
12 F, 333, Dunhua S. Rd., Sec. 2 Taipei Taiwan Edisonstraat 12A 6902 PK ZEVENAAR The Netherlands To: Telefication B.V., Dept. FCC TCB Subject: Request for confidentiality FCC ID: Q3N-1664A Reference number: ######
Dear FCC TCB, 1. Long-Term Confidentiality Pursuant to 47 CFR Section 0.459(a) & (b), we hereby requests non-disclosure and confidential treatment of the following materials submitted in support of FCC certification application:
Bill(s) of Material Block Diagrams Operational Description Schematic Diagrams Tune-up Procedure Above materials contain secrets, proprietary and technical information, which would customarily be guarded from competitors under 47 CFR, section 0.457(d)(2). Disclosure or publication or any portion of this company confidential material to other parties could cause substantial competitive harm and provide unjustified benefits for competitors. 2. Short-Term Confidentiality (STC) Pursuant to Public Notice DA 04-1705 of the Commissions policy, in order to comply with the marketing regulations in 47 CFR 2.803 and the importation rules in 47 CFR 2.1204, applicant hereby requests Short-Term Confidential treatment of the following materials (note 1):
Internal Photos Users Manual Test Set-up Photos External Photos Justification:
Planned Release Date STC: (notes 2, 3, 4, 5). If no date is given, 45 days from grant date will be used. Date: 2021/6/10 Name and signature of applicant: Herbie Jiang Notes:
1) A document or type of document can only have ONE type of confidentiality!
2) Short-Term confidentiality is in principle for 45 days from date of grant; it can be extended max 3 times (total time 180 days max.)!
3) FCC must be informed when marketing begins earlier. 4) Release takes place automatically thus extension must be requested in time. Telefication does not remind you of this!
5) Request for extension or for release must be received by Telefication at least 7 days before date of actual marketing or before expiration of the STC period
1 | Declaration of authorization | Cover Letter(s) | 137.96 KiB | June 28 2021 / June 29 2021 |
Declaration of Authorization We Name:
CIPHERLAB CO., LTD. Chenz Ker MRT Technology (Taiwan) Co., Ltd No. 38, Fuxing Second Rd., Guishan Dist., Taoyuan Taiwan Address:
12 F, 333, Dunhua S. Rd., Sec. 2 City:
Taipei Taiwan Country:
Declare that:
Name Representative of agent:
Agent Company name:
Address:
City:
Country is authorized to apply for Certification of the following product(s):
Product description: BT Barcode Scanner FCC ID: Q3N1664A IC: 5121A1664A Type designation:
Trademark:
Validity/ expiry date: 2021/8/10 on our behalf. 1664 A, 1662 A CIPHERLAB
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2021-06-29 | 2402 ~ 2480 | DSS - Part 15 Spread Spectrum Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2021-06-29
|
||||
1 | Applicant's complete, legal business name |
CipherLab Co., Ltd.
|
||||
1 | FCC Registration Number (FRN) |
0015617624
|
||||
1 | Physical Address |
12F, 333, Dunhua S.Rd., Sec.2, Taipei, Taiwan
|
||||
1 |
Taipei, N/A
|
|||||
1 |
Taiwan
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
c******@telefication.com
|
||||
1 | TCB Scope |
A4: UNII devices & low power transmitters using spread spectrum techniques
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
Q3N
|
||||
1 | Equipment Product Code |
1664A
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
H******** J********
|
||||
1 | Title |
R & D Engineer
|
||||
1 | Telephone Number |
+886-******** Extension:
|
||||
1 | Fax Number |
+886-********
|
||||
1 |
h******@cipherlab.com.tw
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
MRT Technology (Taiwan) Co., Ltd
|
||||
1 | Name |
C**** K********
|
||||
1 | Physical Address |
No. 38, Fuxing Second Rd., Guishan Dist.
|
||||
1 |
Taiwan
|
|||||
1 | Telephone Number |
+8863********
|
||||
1 | Fax Number |
886-3********
|
||||
1 |
c******@mrt-cert.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
MRT Technology (Taiwan) Co., Ltd
|
||||
1 | Name |
C**** K********
|
||||
1 | Physical Address |
No. 38, Fuxing Second Rd., Guishan Dist.
|
||||
1 |
Taiwan
|
|||||
1 | Telephone Number |
+8863********
|
||||
1 | Fax Number |
886-3********
|
||||
1 |
c******@mrt-cert.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DSS - Part 15 Spread Spectrum Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | BT Barcode Scanner | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Grant Comments | Power output listed is conducted. This is a portable device. The device must not be co-located or operating in conjunction with any other antenna or transmitter. End-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
MRT Technology (Taiwan) Co.,Ltd
|
||||
1 | Name |
C****** K******
|
||||
1 | Telephone Number |
+886-********
|
||||
1 | Fax Number |
+886-********
|
||||
1 |
c******@mrt-cert.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 | 0.0022000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC