all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
User Manual | Users Manual | 2.02 MiB | ||||
1 | Block Diagram | |||||||
1 | Schematics | |||||||
1 | ID Label/Location Info | |||||||
1 | Internal Photos | |||||||
1 | Test Report |
1 | User Manual | Users Manual | 2.02 MiB |
EXHIBIT C User Manual _ ss SpeedStream 3000 ADSL Internal Modem Installation Guide Eificient Networks, Ine Part No. 007-3005-001, Rev B Copyright 1999, Efficient Networks, Inc. All rights reserved. Printed in the U.S.A. Product names mentioned herein may be trademarks and/or registered trademarks of their respective companies. Ef-
ficient Networks, Inc. shall not be liable for technical or editorial errors or omissions in this document; nor for inci-
dental or consequential damages resulting from the furnishing, performance, or use of this material. Efficient Networks, Inc. Single-use Software License and Warranty This documentation and the accompanying computer programs (collectively, the Software) are licensed, not sold, to the End User by EFFICIENT NETWORKS, INC. (ENT) for use only under the following terms. ENI reserves any right not expressly granted to the End User. The End User owns the media on which the Software is recorded but ENI retains ownership of all copies of the Software itself. The End User assumes sole responsibility for the installation, use, and results obtained from use of the Software. If the product that you acquired is an upgrade, then the terms and conditions ofthis agreement apply equally to the upgraded product. 1. License. This License allows the End User, together with its authorized employees, to do only the following:
(a) Install and archive the Software on one (and only one) Remote Access Unit, IBM PC, Sun Workstation, or compatible equivalent personal computer or workstation for electronic transfer to, and use and execution on and with one (and only one) module or product of ENI equipment for use only by the End User.
(b) Make one (and only one) copy in machine-readable form solely for backup or archival purposes for the com-
puter on which the Software is installed. The Software is protected by copyright law. As an express condition of this license, the End User must reproduce on the copy the ENI copyright notice and any other proprietary legends on the original copy supplied by ENI. This restriction on copying the Software expires upon the expi-
ration of all underlying copyrights. 2. Restrictions. The End User may NOT sublicense, assign, or distribute copies of the Software to others. The Soft-
ware contains trade secrets and to protect them, the End User may NOT decompile, reverse engineer, disassemble, or otherwise reduce the Software to a human perceivable form. The End User may not modify, adapt, translate, rent, lease, loan, resell for profit, distribute, or otherwise assign or transfer the software, or create derivative works based upon the software or any part thereof. 3. Protection and Security, The End User agrees not to deliver or otherwise make available the Software, including without limitation the object code of the Software, to any party other than its authorized employees, except for pur-
poses specifically related to the End Users authorized use of the Software on ENI Products, without the prior written consent of ENI. The End User agrees to use its best efforts and to take all reasonable steps to safeguard the Software to ensure that no unauthorized person shall have access thereto and that no unauthorized copy, publication, disclosure or distribution in whole or in part, in any form, shall be made. The End User acknowledges that the Software contains valuable confidential information and trade secrets and that unauthorized use and/or copying are harmful to ENI. 4. Termination, This License is effective until terminated. This License will terminate immediately without notice from ENI if the End User fails to comply with any of its provisions. Upon termination, the End User must destroy the Software and all copies thereof, and the End User may terminate this License at any time by doing so. 5. Export Law Assurances, The End User agrees that neither the Software nor any direct product thereof will be transferred or exported, directly or indirectly, into any country prohibited by the U.S. Export Administration Act and the regulations thereunder or will be used for any purpose prohibited by that Act. 6. Limited Warranty. ENI warrants that, for ninety (90) days from the date of shipment, the Software shall operate substantially in accordance with the published functional specifications current at the time of shipment. If a defect appears, during the warranty period, ENI will use its best efforts to correct the defect within a reasonable time after notification. The End User agrees that the foregoing constitutes the End Users sole and exclusive remedy for breach by ENI under any warranties made under this Agreement. This warranty does not cover any Software that has been altered or changed in any way by anyone other than ENI. ENT is not responsible for changes made after ordering the Software to computer hardware, operating systems or test equipment, or for problems in the interaction of the Soft-
ware with software not furnished by ENI. The Warranty and remedy provided above are exclusive and in lieu of all other warranties, express or implied, includ-
ing but not limited to the implied warranties of merchantability and fitness for a particular purpose. The End User assumes all risk as to the suitability, quality, and performance of the software. In no event will ENI, or its directors, officers, employees or affiliates, be liable to the End User for any consequential, incidental, indirect, special or ex-
emplary damages (including damages for loss of business profits, business interruption, loss of data or business in-
formation, and the like) arising out of the use of or inability to use the software or accompanying written materials, even if ENI or an authorized ENI representative has been advised of the possibility of such damages. ENIs liability to the End User (if any) for actual direct damages for any cause whatsoever, and regardless of the form of the action, will be limited to, and shall not exceed, the amount paid for the License of the Software that caused the damages. No oral or written information or advice given by ENI or its dealers, distributors, employees or agents shall in any way extend, modify or add to the foregoing warranty. 7. No Other Rights Granted, Other than the limited license expressly granted herein, no license, whether express or implied, by estoppel or otherwise, is granted to any copyright, patent, trademark, trade secret, or other proprietary rights of ENI. Efficient Networks, inc. , 1 8. Licensee Responsibilty And Indemnification, The End User understands and acknowledges that it is solely re-
sponsible for the use it makes of the Software. Accordingly, the End User agrees to indemnify and hold ENI harmless _ from any demands, claims or suits by a third party for loss, damages or expenses (including attorney's fees) arising out of or related to use of the Software by the End User. 9.Enhancements, From time to time ENI may, in its sole discretion, advise the End User of updates, upgrades, en-
hancements or improvements to the Software and/or new releases of the Software (collectively, Enhancements), and may license the End User to use such Enhancements to the Software upon payment of such prices therefore as may then be established by ENI and in effect. All such Enhancements to the Software provided to the End User shall also be governed by the terms of this License. 10.General. This License will be covered by and construed in accordance with the laws of the State of Texas, and shall inure to the benefit of ENI and its successor, assignees and legal representatives. If any provision of this license is held by a court of competent jurisdiction to be invalid or unenforceable to any extent under applicable law, that provision will be enforced to the maximum extent permissible, and the remaining provisions of this License will re-
main in full force and effect. Any notices or other communications to be sent to ENI must be mailed by certified mail to the following address:
Efficient Networks, Inc. 4201 Spring Valley Road, Suite 1200 Dallas, Texas 75244 This Agreement constitutes the entire agreement between the parties with respect to the subject matter hereof, and all prior proposals, agreements, representations, statements and undertakings are hereby expressly canceled and super-
seded. This Agreement may not be changed or amended except by a written instrument executed by a duly authorized officer of ENI. 11.Acknowledgment, By opening this package, you acknowledge that you have read this License, understand it, and agree to be bound by its terms and conditions. Should you have any questions concerning this License, contact ENI at the address shown above. Efficient Networks, Inc. Hardware Warranty Efficient Networks, Inc. (ENT) warrants SpeedStream 3000 series Network Interface Controller (NIC), SpeedStream 4000 series Universal Serial Bus (USB), and SpeedStream 5000 series Remote Access Unit (RAU) for a period of 5 years against defects in material or workmanship from the date of purchase. SpeedStream 5010 Remote Access Unit
(RAU) is warranted for 13 months against defects in material or workmanship from the date of purchase. These warranties extend only to the original consumer of this product. If the NIC, USB or RAU does not function as warranted during the warranty period, Efficient Networks, Inc. will either repair the defective product or replace it with a new or remanufactured functionally equivalent product of equal value. 2 Efficient Networks, inc. Introduction Product Overview The SpeedStream driver software provides high-speed connectivity using Asynchronous Transfer Mode (ATM) over an Asymmetric Digital Subscriber Line (ADSL). This software is designed to be installed on a 3000 series ADSL Internal Modem. Once it is installed, a modem icon is added to the taskbar and the status of the internal modem can be seen by clicking on the modem icon. Before You Begin The following sections contain information that is essential for you to know before you install the hardware and software for your 3000 series modem. Please read these sections carefully. Checking the Operating System Before beginning the installation, you must determine what operating system is installed on your machine:
1 From the Start menu, point to Settings and click Control Panel; then double-click the System icon. a 2 In the System applet, click the General tab. 3 Note the type of Windows operating system (95, 95A, 95B, 98, or NT) and the version number. Refer to Table 1 for installation requirements that are specific to your machines operating system. Table 1 System Requirements Windows 95/95A/95B * Minimum of 16 Mbytes RAM, 32 Mbytes recommended
* Pentium-class processor required The PCI bus must support bus mastering. Efficient Networks, Inc. Product Overview 3 Table 1 System Requirements Windows 98 * Minimum of 32 Mbytes recommended
* Pentium-class processor required
* The PCI bus must support bus mastering. At least one Virtual Private Networking (VPN) Adapter must be installed. Windows NT * Minimum of 32 Mbytes recommended
* Pentium-class processor required
* The PCI bus must support bus mastering. Service Pack 3 or greater must be installed. NOTE: You may need the Windows (95, 98 or NT) operating system CD during installation. If you do not have this CD, contact your PC vendor for details on where the Windows files are stored on your machine. Tools Needed for Hardware Installation In order to properly install the modem hardware, you will need a few items:
+ A Phillips-head screw driver and any other screw-drivers needed for your PC
* A cable with RJ11 (or RJ45 for 3010 only) connectors on each end An anti-static discharge protection device such as a wrist strap or a heel strap. The anti-static discharge protection device is required when handling the modem and prevents damage to the electronic components. Do not leave this to chance! Not using anti-static protection may result in serious damage to the hardware. 4 Product Overview Efficient Networks, inc. Hardware Installation Unpacking and Inspection 4 The SpeedStream internal modem should arrive in good condition. Before unpacking the modem, check for any obvious damage to the packaging and notify your carrier immediately upon receipt. WARNING! To avoid possible damage to modem components or your system, use an anti-static grounding device when handling the modem. 1 When handling the internal modem, if you do not have an anti-static wrist-strap or other device on, you can hold onto the metal chassis of the PC to provide anti-static grounding. Remove the modem from the anti-static bag and check for any damage. If there are any visible signs of damage, contact Efficient Networks Customer support for a Return Materials Authorization number. Please return the modem in the original anti-static bag and the original shipping container. NOTE:
1 A suitable Electrical and Fire enclosure shall be provided in the end product. This product is a modem card intended for installation in SELV circuits of personal computers or similar equipment. After installation of this modem card in the end product, the end product should be in compliance with the enclosure, mounting, creepages and clearances, markings and segregation requirements of the end user application. Notably, the end products should provide installation instructions detailing how to install/remove card cage accessories. Efficient Networks, Inc. Unpacking and inspection 5 Installing the Modem 1 Shut down the system and turn it off. 2 Unplug the system from the power source. 3 Remove the cover of the system chassis. 4 Touch the system chassis or connect the copper end of the anti-static wrist strap to a metal component of the chassis to provide grounding. 5 Insert the modem into an empty PCI slot after removing the slot cover, as shown in Figure 2. (The slot cover is the metal strip that covers the opening in the back of the computer chassis into which the host modems external connector fits.) Figure 2 Inserting the modem into the PCI Slot 6 Press the modem firmly into the slot to ensure that it is properly seated. Secure the modems end bracket to the chassis with the bracket screw. 7 Replace the chassis cover and apply power to the machine. 6 = Installing the Modem Efficient Networks, Inc. Modem LEDs The modem is equipped with an LED that indicates proper cable connection. This LED is helpful when connecting cabling because it indicates when the cables have been hooked up correctly. The LED is illuminated when the modem is trained and is passing ATM data properly. NOTE: The LED will be [it or will flash when the modem is in diagnostic loopback mode regardless of what is connected to it. 3010 Connector Information The pinout of the modems Category 3 and 5 Transmit +
UTP jack is different than a standard Ethernet fransmit -
UTP jack. _ Receive -
Ethernet loopback connectors will not work 12345678 on the port and vice versa. Ue Once the connector is plugged into a board that is installed in a chassis, the removal lever on the connector may be hard to reach. Do not try to pull the connector out of the port without pushing up on the removal lever. RJ45 Connector removal lever 3020 and 3060 Connector Information The modem comes with an RJ11 jack that uses pins RJ11 Jack 3 and 4. Optionally, the modem may be configured Pinout to use pins 2 and 5. If so, the modem markings will 123456 indicate this. Efficient Networks, inc. Installing the Modem =
Software Installation Software Installation Overview Two types of software drivers are provided on the installation CD: PPP and CIP/1483. Your service provider will tell you which of these two types of drivers you need to install. Furthermore, the first chapter provides a procedure for determining which Windows operating system is installed on your computer to know which version of these drivers to install. Follow the links below to guide you to the correct procedure for installing your 3000 series modem driver. To install the PPP Software...
+--D> in Windows 95 or 95A go to page 10
;--> in Windows 95B........... go to page 12
+--+ in Windows 98............. go to page 16
.-- > In Windows NT............. go to page 19 To install the CIP/1483 Software...
-- > in Windows 95 or 95A go to page 23
--f> in Windows 95B.......... go to page 24 t--> in Windows 98............. go to page 28
---p in Windows NT............ go to page 31 8 Software Installation Overview Efficient Networks, Inc. Installing PPP Software The PPP driver uses Microsofts Dial-Up Networking to create a connection. You must have Dial-Up Networking v1.2 or greater installed to properly install the PPP driver. Refer to the Introduction section of this manual for more detail. Installation Requirements for PPP in Windows 95/98 Dial-Up Networking (DUN) If you will be installing in Windows 95 or Windows 98, you will need the Microsoft Dial-Up Networking application installed. This applet is usually installed with Windows 98, but the person installing the OS may have chosen not to install it. Windows 95 operating systems will have to be upgraded to the correct version of DUN. To determine if you have the DUN application installed, select Start >
Settings > Control Panel and Add/Remove Programs to ensure that there is at least one Dial-Up Adapter installed. If there is not, before installing the internal modem hardware, refer to the procedures below to install DUN on your system:
1 Double-click the My Computer icon on your desktop. 2 Double-click:
Your CD-ROM drive letter. Msdun13.exe 3 When you are asked Install MSDUN1.3, continue?, click Next. 4 When you are prompted to restart, click Yes. Virtual Private Networking The Microsoft Virtual Private Networking (VPN) adapter is required by the PPP driver. The VPN adapter is normally provided in Windows 98 Efficient Networks, Inc. installing PPP Software 9 installation. If it has not been installed or was removed, it must be re-installed. To check whether VPN is installed:
1 Select My Computer > Control Panel > Network. 2 On the Configuration list, there should be a Microsoft Virtual Private Networking Adapter listed. 3 Ifnot, select the Add button and double-click on Adapter. 4 Scroll down in the Manufacturers list and select Microsoft. 5 Under Network Adapters, double-click on Microsoft Virtual Private Networking Adapter. Installation in Windows 95 or Windows 95A 1 Affer installing the modem hardware, power on the system. When Windows comes up, insert the software installation CD in the CD-ROM drive. 2 Windows will bring up the New Hardware Found dialog box. Be sure that Driver from disk is selected before you click OK. driver you wantton rdiver alla diver. 10 = Installing PPP Software Efficient Networks, Inc. 3 Next, the Install From Disk dialog box will appear. Click Browse and select the CD-ROM drive from the Drives list. 4 Double-click W95-98 and Ppp then click OK. 5 Click OK or Next on the Install From Disk dialog box. Petes jj 6 Windows will then begin copying the driver files. After the files are copied, the installation is complete and Windows will be restarted. During this process you may be prompted for the Windows 95 OS installation CD-ROM. If so, insert the CD and enter the path to the requested files. Click OK. 7 At this point, if Dial-Up Networking (DUN) is not installed, a message is presented saying:
An incorrect version of Dial-Up Networking is installed. Speedsiream PPP requires Dial-Up Networking version 1.2 or better to run. Please consult the release notes regarding Dial-Up Networking 1.2 installation before you continue. If this message appears, click OK and refer to the DUN installation instructions on page 9. 8 When the system comes back up, one or more configuration dialog boxes may or may not be presented, depending on your service provider. Configure the settings as directed by your network service provider. When configuration is complete, if prompted to restart Windows, click Yes. 9 When the system comes back up, you will need to set up your PPP dial-up connection as described on page 22. Efficient Networks, Inc. Installing PPP Software 11 Installation in Windows 95B 1 After installing the modem hardware, power on the system. When Windows comes up, insert the software installation CD in the CD-ROM drive. 2 The Update Device Driver Wizard dialog (shown on the next page) will appear. Click Next. Update Device Driver Wizard 12 Installing PPP Software Efficient Networks, Inc. 3 On the next dialog box, click the Other Locations button.
, ish. To ther Locations. 3-a On the Select Other Locations dialog, select Browse. 3-b Click on the CD-ROM drive in the list, select W95-98 and Ppp then click OK. On the Select Other Location dialog, click OK. Efficient Networks, Inc. Installing PPP Software 13 14 4 On the Update Device Driver Wizard, click Finish. Tha ed esc Please insert Windows will then begin copying the driver files. During this process you may be prompted for the Windows 95 OS installation CD-ROM. If so, insert the CD and enter the path to the requested files. Click OK. 6 At this point, if Dial-Up Networking (DUN) is required (for PPP drivers only) but it is not installed, a message is presented saying:
An incorrect version of Dial-Up Networking is installed. Speedstream PPP requires Dial-Up Networking version 1.2 or better to run. Please consult the release notes regarding Dial-Up Networking 1.2 installation before you continue. If this message appears, click OK and refer to the DUN installation instructions on page 9. Installing PPP Software Efficient Networks, Inc. 7 When the system comes back up, one or more configuration dialog boxes may or may not be presented, depending on your service provider. Configure the settings as directed by your network service provider. When configuration is complete, if prompted to restart Windows, click Yes. 8 When the system comes back up, you will need to set up your PPP dial-up connection as described on page 22. Troubleshooting Windows 95 Installation Recovery from Canceling installation An incomplete installation may occur if:
* In Windows 95 or 95A, if you select Do not install a driver on the New Hardware Found dialog box In Windows 95B, if you click Finish on the Update Device Driver Wizard dialog box without inserting the SpeedStream installation CD Use the following procedure to clear the partial install from the system. 1 Click Start and point to Settings; then click Control Panel. Double-click System and click the Device Manager tab. Select the ENI card under * Other devices. 2 Click Remove. Exit the Device Manager and reboot the machine. 3 Shut down and restart the system; then perform the software installation procedure again. PPP Driver Installation without Dial-Up Networking If the drivers are installed on a system that does not have the latest version of DUN installed, the installation procedure describes what will occur. If the system is not restarted as required during DUN installation, the installation software will not be able to create address book entries. To recover from this situation, use the following procedure to update the service profile:
Efficient Networks, inc. Installing PPP Software 15 1 Click Start > Settings > Control Panel > Network and click the Adapters tab (if not already selected). Select the Efficient client and click the Properties button. 2 Click Update. 3 Find the profile (.acf file) on the SpeedStream installation CD using the standard Open dialog box provided. 4 SpeedStream configuration dialog boxes will be presented and the necessary address book entries will be created. Restart Windows. Installation in Windows 98 1 After installing the modem hardware, power on the system. 2 When the system comes up, the Add New Hardware Wizard will appear indicating that the modem was discovered. Add ren rer ee ee 3 Insert the installation CD-ROM and click Next. 16 = Installing PPP Software Efficient Networks, inc. 4 On the next dialog, the first option Search for the best driver for your device (Recommended) should be selected. s. ia specific select the driver you wart. 5 On the next dialog, select only the checkbox labeled Specify a location. Then click the Browse button. FT} ee Tere zard Efficient Networks, Inc. installing PPP Software 11 5-a In the browse list, locate your CD-ROM drive letter and highlight it, then select the W95-98 folder and Ppp then click OK. 5-b Click Next on the Add New Hardware Wizard dialog box. 6 The Add New Hardware Wizard states that Windows is now ready to install the best driver for this device. Click Next. Windows will then copy the driver files from your CD-ROM. As the files are being copied, you may be prompted for the Windows 98 CD. If so, insert the CD and click OK. 7 Next you may see the Insert Disk dialog box. Click OK. 8 On the Copying Files dialog box, pull down the Copy files from:
list and select <drive>: W95-98\Ppp. Click OK. 9 Click Finish on the Add New Hardware Wizard. 40 When the driver installation is complete, you will be prompted to restart Windows. Click Yes. 41 When the system comes back up, one or more configuration dialog boxes may or may not be presented, depending on your service provider. Configure the settings as directed by your network service provider. 12 Click the Finish button to complete the configuration. 13 When the driver installation is complete, set up your dial-up connection as described on page 22. 18 Installing PPP Software Efficient Networks, Inc. Installation in Windows NT 4.0 NOTE: The user must have Administrator rights on the system in which the modem is being installed. 1 After installing the modem hardware, power on the system. When Windows NT comes up, log in and insert the SpeedStream installation CD in a CD-ROM drive. 2 Click the Start button and point to Settings; click Control Panel. Double-click the Network icon. ie Control Panel ca
| Accessibility AddNew Add/Remove Date/Time Desktop i Options Hardware Programs a G Game Intetnet Controllers Options Multimedia ODBC Data = Passwords Power Printers Sources (32bit) Management 3 &
Regional System Telephony Users Settings 3 When the Network window appears, click the Adapters tab and then click the Add button. Efficient Networks, Inc. Installing PPP Software 19 4 On the Select Network Adapter dialog box, click the button labeled Have Disk. ei een rk aren
~]B9 Accton EN1B6x MPX2 Pn EY Adaptec ATM LAN Emulation Adapter 2 (EB Advanced Micra Devices AM2100/AM1500T Adapter EY Allied Telesyn AT1700 Ethernet Adapter BB Allied Telesyn AT-2560 Series PCI/100 Ethernet Adapter EB AMD PCNET Family Ethernet Adapter BR Andrew ISA IIA Token Ring Adanter 5 In the Insert Disk dialog box, you must specify the CD file path. (If you do not know the CD-ROM drive letter, then look on the My Computer dialog box.) Enter the following: <drive:>\NT\Ppp and click OK. 6 On the Select OEM Option dialog box, you will see the driver highlighted. Click OK. The Windows NT Setup dialog box will show the files being copied. 7 Ifa Remote Access Services Installation dialog box appears, this indicates that RAS has not been installed previously on your system. You will need the Windows NT 4.0 Installation CD to install RAS. 7-a Insert the Windows NT CD. 7-b The dialog box will prompt you to enter the directory path where the RAS services are installed (enter <drive>:\i386 where <drive> is the CD drive letter). You must enter the correct path name to the RAS service. If the path is entered wrong, cancel the RAS installation. Go to your Network settings by clicking on the Start button and 20 = Installing PPP Software Efficient Networks, Inc. selecting Settings; click on Control Panel. Double-click on the Network icon and then click Services and Add. Select Remote Access Services from the list and click OK. 8 Next, the Remote Access Services configuration dialog box is presented, and then the Add RAS Device dialog box appears. 8-a Select the entry labeled ISDN_n ENxOP and click OK. 8-b Click the Configure button. 8-c On the Configure Port Usage dialog box, select Dial Out Only and click OK. 8-d Click Network and make sure TCP/IP is checked. Click OK. 8-e Click Continue when all configuration is complete. 8-f Exit the Network Control Panel by clicking Close. 8-g When prompted to, restart the system. If you have more than one client connection, repeat the following procedure for each client:
8-h_ Click the Start button and select Settings; click Control Panel. 8-i Double-click the Network icon and click the Services tab. 8-j Select Remote Access Services from the list and click the Properties button. 8-k Click the Add button in the Remote Access Setup dialog box to add your additional client connection. Click OK. 8-1 Repeat steps 8-b through 8-g above. NOTE: Microsoft recommends that you re-install the latest Service Pack for your system after installing RAS. Refer to instructions in the Release Notes for installing the latest service pack. 9 When the system comes back up, one or more configuration dialog boxes may or may not be presented, depending on your service provider. Configure the settings as directed by your network service provider. Efficient Networks, Inc. Installing PPP Software 21 10 Click the Finish button to complete the configuration. Setting up a PPP Connection After installing the PPP software, you may be required by your service provider to configure the IP address before you connect using Dial-Up Networking. If so, following your service providers instructions to configure your IP address, then follow the procedure below to create a connection. Creating a PPP Connection 1 Double-click the My Computer icon on your desktop; then double-click the Dial-Up Networking icon. 2 You will see an icon for the ADSL PPP connection that was defined when you installed the driver. Double-click on the connection icon. 3 Enter a password. 4 Select the Connect button to create the connection. 5 A modem icon will then appear on the taskbar when the connection has been established. Using SpeedStream with Multiple User Profiles 22 If your system was configured with multiple user profiles before the modem was installed, the SpeedStream connection will only be visible to the user who installed it. To copy the connection to other users profiles, copy all files in your Dial-Up Networking folder with a .dun extension to c:\. Then login as each individual user and copy the .dun files to the Dial-Up Networking folder. Installing PPP Software Efficient Networks, Inc. CIP/1483 Driver Installation The Classical IP/RFC 1483 Driver differs from the PPP driver because it provides an always-on network connection. The CIP/1483 driver does not use Dial-Up Networking. Installation in Windows 95 or 95A 1 Afier installing the modem hardware, power on the system. When Windows comes up, insert the software installation CD in the CD-ROM drive. 2 Windows will bring up the New Hardware Found dialog box. Be sure that Driver from disk is selected before you click OK. tom EC Lm mele ot install a driver (Windows Select ftom &
3 Next, the Install From Disk dialog box will appear. Click Browse and select the CD-ROM drive from the Drives list. 4 Double-click W95-98 and Cip-1483, then click OK. Efficient Networks, Inc. CIP/1483 Driver Installation 23 5 Click OK on the Install From Disk dialog box. fufacturer's it id then cl Copy manufactia AW95-98 \Cl 6 One or more configuration dialog boxes will be presented, depending on your service provider. Configure the settings as directed by your network service provider.When you click Finish, Windows will then begin copying the driver files. During this process you may be prompted for the Windows 95 installation CD-ROM. If so, insert the Windows 95 CD-ROM and click OK. 7 When Windows comes up, you may need to configure the Internet Protocol (IP) address for your connection. Refer to the procedure on 30. Installation in Windows 95B 1 After installing the modem hardware, power on the system. When Windows comes up, insert the SpeedStream installation CD in the CD-ROM drive. 2 The Update Device Driver Wizard dialog (shown on the next page) will appear. Click Next. 24 ~~ CIP/1483 Driver installation Efficient Networks, inc. pdate Device Driver Wizar
> installation of ext to continue:
3-a On the Select Other Locations dialog, select Browse. Efficient Networks, Inc. CIP/1483 Driver Installation 25 3-b Click on the CD drive in the list, double-click on W95-98 then CIP-1483 and click OK. On the Select Other Location dialog, click OK. 4 On the Update Device Driver Wizard, click Finish. 5 Next, the Insert Disk dialog may appear. Click OK. Insert Disk I 6 On the Copying files dialog box, click Browse and then select W95-98 and Cip-1483. Click OK. Windows will then begin copying the driver files. 7 One or more configuration dialog boxes will be presented, depending on your service provider. Configure the settings as directed by your network service provider. 8 You may be prompted for the Windows 95 installation CD. If so, insert the CD and click OK 9 When the system comes back up, you may need to configure the Internet Protocol (IP) address for your connection. Refer to the procedure on 30. 26 = CIP/1483 Driver Installation Efficient Networks, inc. Troubleshooting Windows 95 Installation Recovery from Canceling Installation An incomplete installation may occur if:
* In Windows 95 or 95A, if you select Do not install a driver on the New Hardware Found dialog box In Windows 95B, if you click Finish on the Update Device Driver Wizard dialog box without inserting the SpeedStream installation CD Use the following procedure to clear the partial install from the system. 1 Click Start and point to Settings; click Control Panel and double-click System. Then click the Device Manager panel and select the ENI card under * Other devices. 2 Click Remove. Exit the Device Manager and reboot the machine. 3 Shutdown and restart the system, then perform the software installation procedure again. Efficient Networks, Inc. CIP/1483 Driver Installation 27 Installation in Windows 98 1 After installing the modem hardware, power on the system. 2 When the system comes up, the Add New Hardware Wizard will appear indicating that the modem was discovered. Add New rT are Dre C 3 Insert the installation CD-ROM and click Next. 28 = CIP/1483 Driver installation Efficient Networks, Inc. 4 On the next dialog, the first option Search for the best driver for your device (Recommended) should be selected. Click Next. GTR St rte ara.) Co a 5 On the next dialog, select only the checkbox labeled Specify a location. Then click the Browse button. Efficient Networks, inc. CIP/1483 Driver Installation 29 5-a In the browse list, double-click on the CD-ROM drive letter, then select the W95-98 folder and Cip-1483 and click OK. 5-b Click Next on the Add New Hardware Wizard dialog box. 6 The Add New Hardware Wizard states that Windows is now ready to install the best driver for this device. Click Next. Windows will then copy the driver files from your CD-ROM. 7 Next you may see the Insert Disk dialog box. Click OK. Disk 8 On the Copying Files dialog box, pull down the Copy files from:
list and select <drive>: W95-98\Cip-1483. Click OK. _ 9 Next, configuration dialog boxes will be presented. Use your service providers instructions to set the parameters. Click the Finish button to complete the configuration. As the files are being copied, you may be prompted for the Windows 98 CD. If so, insert the CD and click OK. 10 Click the Finish button to complete the configuration. When the driver installation is complete, you will be prompted to restart Windows. Click Yes. 11 When the system comes back up, you may need to configure the Internet Protocol (IP) address for your connection. Refer to the procedure below. Configuring the IP Address in Windows 95/98 When using the CIP/1483 driver, you may need to configure an Internet Protocol (IP) address that will be used to identify your computer on the network. 30 CIP/1483 Driver Installation Efficient Networks, Inc. 1 Double-click the My Computer icon on your desktop and then double-click Control Pane! followed by Network. 2 Select the TCP/IP entry for the SpeedStream device and click then Properties button. 3 Follow your service providers instructions to configure the IP address of your system. 4 When configuration is complete, click OK. You may be prompted to reboot the computer. If so, select Yes. Installation in Windows NT 4.0 1 After installing the modem hardware, power on the system. When Windows NT comes up, log in and insert the driver installation CD in a CD-ROM drive. 2 Click Start and point to Settings; then click Control Panel. Double-click the Network icon. 3 When the Network window appears, click the Adapters tab and then click the Add button. Efficient Networks, inc. CIP/1483 Driver Installation = 311 4 On the Select Network Adapter dialog box, click the button labeled Have Disk. Network Adapter 89 Accton EN166x MP2 PnP Ethernet Adapter a]
JS Adaptec ATM LAN Emulation Adapter
{88 Advanced Micro Devices AM2100/AM1500T Adapter BB Allied Telesyn AT1700 Ethemet Adapter BR Allied Telesyn AT-2560 Series PCI/100 Ethemet Adapter
(B9 AMD PCNET Family Ethemet Adapter
{BB Andrew ISA IIA Token Ring Adapter 5 On the Insert Disk dialog box, you must specify the CD file path. If you do not know the CD-ROM drive letter, then click on My Computer and look for the CD-ROM drive letter. Enter the following: <drive:>\NT\Cip-1483 and click OK. 6 On the Select OEM Option dialog box, you will see the driver highlighted. Click OK. The Windows NT Setup dialog box will show the files being copied. 7 Next, a series of configuration dialog boxes will be presented. Configure the settings as directed by your network service provider. Click the Finish button to complete the configuration. 8 Select Close on the Network dialog. 9 Next, the Microsoft TCP/IP Properties dialog is presented. Pull down the Adapter list and select the SpeedStream client. 10 Follow your service providers instructions to configure the IP address of your system. Click OK. This completes the configuration of the modem. CIP/1483 Driver Installation Efficient Networks, inc. SpeedStream Status After the modem and driver are properly installed, you will see the following icons on the taskbar:
Indicates that the modem has an active connection. The lights will blink when the modem is transmitting.
( Indicates that the modem is not connected or configured
! properly. Right-clicking on the taskbar icon provides a menu of detailed status and on-line help. The taskbar icon can be turned off by going to the Control Panel and double-clicking the SpeedStream Status icon. This will bring up the SpeedStream Status dialog box. The icon is displayed when the Show Icon on Taskbar checkbox is checked. Efficient Networks, inc. SpeedStream Status 33 Software Removal Removing the Driver Software - Windows 95/98 1 2 Select Start then Settings and open the Control Panel. From the Control Panel, select Network. Select the Configuration tab and select the SpeedStream product from the list. Click on the Remove button and select OK to close the Network dialog. When prompted to restart the system, select No. Shut down Windows and turn off the machine. Remove the adapter from the machine and turn the system back on. Removing the Driver Software - Windows NT 1 2 Select Start, then Settings and open the Control Panel. From the Control Panel, select Network. Select the Adapters tab and select our product from the list. Click on the Remove button and then click Yes. Select Close on the Network dialog. When prompted to restart the system, select No. Shut down Windows and turn off the machine. Remove the adapter from the machine and turn the system back on. 34 Removing the Driver Software - Windows 95/98 Efficient Networks, Inc. Technical Reference SpeedStream 3010 Adapter Specifications Size Weight Power Temperature Humidity PCI Frequency Bus Master 2.5 in. x 5.0 in.
{6.3 cm x 12.7 cm) 3 oz. (85.04 grams) Max 1.5 amps @ +5V + 5%
Max 0.2 amps @ +12V + 5%
Operating: 0 to 70 C Non-Operating, storage: -10 to 85 C 10% to 90% noncondensing 0 to 33MHz 32 bit, 33 Mhz PCI bus version 2.1 Bus Master capability with DMA bursting Unshielded Twisted Pair Interface Cabling Connector Operating distance Line code Line rate Rate tolerance Transmitter type Differential Signal Level Rise/Fall time Receiver Unshielded Twisted Pair (UTP) Category 3, 4, or 5 Eight-contact, shielded RJ45 Omto 100m 4B/5B and NRZ 32 Mbaud, 25.6 Mbits per second
+100 ppm Transformer-coupled differential line driver 2.7 3.4 V peak-to-peak 1.5 ns to 3.5 ns Transformer-coupled differential line receiver with adaptive equalization SpeedStream 3020/3060 Adapter Specifications Size Weight Power Efficient Networks, Inc. 6.85 in. x 4.2 in.
(17.39 cm x 10.66 cm) 3 oz. (85.04 grams) Max 1.5 amps @ +5V + 5%
Max 0.2 amps @ +12V + 5%
SpeedStream 3010 Adapter Specifications 35 Temperature Operating: 0 to 70 C Non-Operating, storage: -10 to 85 C Humidity 10% to 90% noncondensing PCI Frequency 0 to 33MHz Bus Master 32 bit, 33 Mhz PCI bus version 2.1 Bus Master capability with DMA bursting Cabling Unshielded Twisted Pair Connector RJ11 Operating distance up to 15 Kft AWG 26, 18 Kft AWG 24 Line code DMT, FDM, ADSL Line rate Up to 640 Kbps upstream, up to 6.1 Mbps downstream Bit Error Rate 10-7 using a 6 dB margin Transmitter type Transformer-coupled differential line driver Line Power PSDM per TIE1.413 POTS Splitter Equipped with a high pass filter Receiver Transformer-coupled differential line receiver with adaptive equalization 36 SpeedStream 3020/3060 Adapter Specifications Efficient Networks, Inc.
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2000-06-21 | JBP - Part 15 Class B Computing Device Peripheral | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2000-06-21
|
||||
1 | Applicant's complete, legal business name |
CIS Technology Inc
|
||||
1 | FCC Registration Number (FRN) |
9999999999
|
||||
1 | Physical Address |
16F, No 75 Hsin Tai Wu Rd.
|
||||
1 |
Hsi Chih, Taipei Hsien, N/A
|
|||||
1 |
Taiwan
|
|||||
app s | TCB Information | |||||
n/a | ||||||
app s | FCC ID | |||||
1 | Grantee Code |
L4O
|
||||
1 | Equipment Product Code |
WSAD80PST
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
J******** L******
|
||||
1 | Title |
Manager
|
||||
1 | Telephone Number |
886 2********
|
||||
1 | Fax Number |
886 2********
|
||||
app s | Technical Contact | |||||
1 | Firm Name |
TRAINING RESEARCH CO., LTD.
|
||||
1 | Name |
J****** T********
|
||||
1 | Physical Address |
NO. 2, LANE 194, HUAN-HO STREET, HSICHIH
|
||||
1 |
TAIPEI HSIEN, TAIWAN
|
|||||
1 |
TAIPEI HSIEN, 221
|
|||||
1 |
Taiwan
|
|||||
1 | Telephone Number |
886-2******** Extension:
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
j******@trclab.com.tw
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
TRAINING RESEARCH CO., LTD.
|
||||
1 | Name |
J****** T******
|
||||
1 | Physical Address |
NO. 2, LANE 194, HUAN-HO STREET, HSICHIH
|
||||
1 |
TAIPEI HSIEN, TAIWAN
|
|||||
1 |
TAIPEI HSIEN, 221
|
|||||
1 |
Taiwan
|
|||||
1 | Telephone Number |
886-2******** Extension:
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
j******@trclab.com.tw
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | JBP - Part 15 Class B Computing Device Peripheral | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | ADSL Modem | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Training Research Co., Ltd.
|
||||
1 | Name |
J****** T******
|
||||
1 | Telephone Number |
886-2********
|
||||
1 | Fax Number |
886-2********
|
||||
1 |
r******@trclab.com.tw
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15B |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC