CONTENT /
ENGLISH PROCLINICAL 250RC ELECTRIC TOOTHBRUSH INSTRUCTION MANUAL INSTRUCTION MANUAL CONTENT......................... ............................... 2-3 2-3 ENGLISH ......................... 5-9
.............................. 10-15 EUROPE .......................... 16 AUSTRALIA ..................... 17 CONSUMER AFFAIRS....... .................. 18 18 COLGATE PROCLINICAL 250RC ELECTRIC TOOTHBRUSH 1 - replaceable brush head 2 - on/off button 3 - brush handle 4 - charging base PROCLINICAL 250RC 1 -
2 - /
3 -
4 -
IMPORTANT SAFEGUARDS When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following:
GET STARTED READ ALL INSTRUCTIONS BEFORE USING WARNING Toothbrushes can be used by children and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Not suitable for children under 3. Keep out of reach of small children Cleaning and user maintenance shall not be made by children without supervision. Children shall not play with the appliance. The supply cannot be replaced. If the cord is damaged, the appliance must be scrapped. Stop using this toothbrush if it is damaged in any way (cord, plug, brush head, toothbrush handle, charger and/or AC adaptor). Use this product only for its intended use as described in this manual. Do not use brush heads, charger, or attachments not recommended by Colgate. Use the charger only within rated capacity of outlets or voltages No user servicable parts. Do not disassemble the handle except for battery disposal, as it may cause personal injury or device failure. If after using this toothbrush you experience excessive bleeding or if bleeding continues to occur after a week of use, please contact your dentist as it may be an indication of a more serious oral care issue. If you are undergoing treatment for any oral care condition, consult your dental professional prior to use. Do not place or store product where it can fall or be pulled into a tub or sink. Do not reach for a charger that has fallen into water. Unplug immediately. AC adaptors and chargers should always be completely dry when connecting to power. SAVE THESE INSTRUCTIONS 2 3 1 4 1 Charge your toothbrush
(charge at least 10 hours the time) charge light pulses green while charging charge light turns solid green when fully charged leave charger unplugged between charges when brush is on, charge light flashes red when battery is low and needs to be recharged Clean brush and charger dry handle and charger completely before putting handle back in charger never put charger in water CHARGING BASE: INPUT 100-240VAC,50/60HZ BATTERY REMOVAL FOR RECYCLING CLEANING INSTRUCTIONS Clean your toothbrush head thoroughly after each use by removing the brush head from the handle and rinsing under running water. Regularly clean the handle and charging base of the Colgate toothbrush using a damp cloth. This is especially important if your toothpaste contains baking soda or other bicarbonates or peroxide. Otherwise, plastic cracking could occur. CORRECT DISPOSAL Do not throw away this product with normal household waste at the end of its life. Always remove battery before discarding. Please use a return collection system to ensure responsible and environmentally safe recycling of the device and battery. REMOVE BATTERY BEFORE DISPOSAL Remove recyclable rechargeable battery in the compliance with environmental regulations before disposing of the toothbrush. Do not open handle unless permanently disposing (will void warranty). TO REMOVE BATTERY FROM HANDLE:
STORAGE INSTRUCTIONS AND DEVICE MAINTENANCE The following maintenance instructions are important to ensure that your brush continues to work as it was designed. Failure to follow these instructions may cause your device to stop functioning altogether. Dentists and hygienists recommend replacing your toothbrush If you plan to stop using the toothbrush for an extendd period, we recommend that you unplug the charging base, clean the toothbrush handle and heads, and store them in a cool dark place. If you start using your toothbrush again after a long period of non-
use, place it on the charger for at least 10 hours. every 3 months. ELECTROMAGNETIC COMPATIBILITY The Colgate ProClinical 250R electric toothbrush complies with all standards regarding electromagnetic handled properly according to the instructions provided in this manual. It is safe to use if Snap brush at seam Holding stem, slide brush 2 internals out 1 3 CLIC K 3 4 7 2 3 4 5 Turn your toothbrush ON and brush timer alerts every 30 seconds to brush different area of your mouth brush stops after 2 minutes 2 6 Replace your brush head every three months NOTICE For energy savings purposes, charge only when the battery level is too low. When not in use, keep the charger unplugged from the socket. Pinch base of clear cover by carefully pry battery away from switch area to release snaps, head screw driver, Using slide battery and circuit board out housing and printed circuit board. Apply tape to terminals at ends of battery to avoid shorting. 4 8 9 FCC Statement:
Industry Canada Statement:
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interfer-
ence that may cause undesired operation of the device. The device is compliance with RF field strength limits, users can obtain Canadian information on RF exposure and compliance. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploita-
tion est autorise aux deux conditions suivantes :(1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. Le prsent appareil est conforme de ce matriel aux conform-
its ou aux limites dintensit de champ RF, les utilisateurs peuvent sur lexposition aux radiofrquences et la conformit dacqurir les informations correspondante. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
receiver.
different from that to which the receiver is connected.
technician for help Reorient or relocate the receiving antenna. Increase the separation between the equipment and Connect the equipment into an outlet on a circuit Consult the dealer or an experienced radio/TV The device must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions : (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 3 100-240VAC,50/60HZ WARRANTY WARRANTY 3 10 ProClinical 260 1 3 2 4 NiMH 1 10 3 CLIC K 4 12 30 2 2 11 3 CONSUMER AFFAIRS /
Call free: 00-800-321-321-32 1800 802 307 0800 441 740 This product is covered by a warranty against defects for a period of 2 years from the date of original product purchase within Australia or New Zealand. This warranty is given by Colgate-Palmolive Australia Pty Ltd (345 George St, Sydney NSW). In the unlikely event of failure or defects resulting from faults in materials or manufacturing arising during the warranty period, we will repair, replace, or refund the goods. We will cover the cost of repair, replacement or refund and cover the postage costs associated with returning the product for assessment, as below . You will be responsible for any other costs associated with making a claim under this warranty. EU Authorized Rep: Colgate-Palmolive (U.K.) Ltd. Guildford GU2 8JZ, UK DUBLIN 24, IRELAND 345 GEORGE STREET, SYDNEY 45 KNIGHTS ROAD, LOWER HUTT, NZ www.colgate.eu.com www.colgate.com.au Manufacturer: Colgate-Palmolive Europe, SARL, 4106 Therwil/Switzerland 338 510730 EUROPEAN ECONOMIC AREA (EEA) IRELAND AND UNITED KINGDOM WARNING AUSTRALIA WARRANTY WARNING: Supply connection - Type C plug provided is intended for use in a Shaver Socket. It is not suitable for connection to a UK mains socket unless used with an approved (e.g. BSI or ASTA) FUSED Convertor Plug with 3A max. fuse or Shaver Adaptor with 1A fuse. 30 DAY MONEY BACK GUARANTEE with this product, return the Try Colgate ProClinical toothbrush for 30 days from date of purchase. If you are not product within 45 days of purchase for a refund of the purchase price
(shipping and handling excluded). You must return the product in its original box with all contents: handle, charger together with the original receipt showing this product was purchased in the United Kingdom or Republic of Ireland. Please allow 4-5 weeks for handling. For further details, please contact your local Colgate Consumer Affairs team 00-800-321-321-32 (free from landlines and mobiles). brush heads, Consumers have statutory rights under applicable national laws relating to the sale of consumer products which are in no way affected by the above. WARRANTY Colgate-Palmolive UK Limited grants a 2 year warranty on this product from the date of purchase within the United Kingdom or Republic of Ireland. Within the warranty period, we will repair or replace the product (the choice of whether to repair or replace being ours) in the unlikely event of failure or defects resulting from faults in materials or manufacturing. Following any replacement, the warranty will continue from the date of original purchase only. This warranty does not cover brush heads, or any damage due to improper use
(any use not in accordance with the User Manual Instructions and Warnings) or normal wear of use. To obtain service within the warranty period, please contact our local Colgate Consumer Affairs team 00-800-321-321-32 (free from landlines and mobiles) To make a claim under this warranty, you must:
Cease using the product;
Contact Colgates Consumer Information Service on 1800 802 307 (AU) or 0800 441 740 (NZ) or at www.colgatepalmolive.com. au/contact-us to obtain a reference number for your claim.
(In Australia) Return the goods, along with a copy of your original purchase receipt showing purchase within 2 years of the current date and include your reference number , name, address and telephone/email contact to:
Colgate-Palmolive Consumer Information Service Reply Paid 3964 Sydney NSW 2000
(NO POSTAGE REQUIRED) Or
(In New Zealand) Return the goods, along with a copy of your original purchase receipt showing purchase within 2 years of the current date and include your reference number, name, address and telephone/email contact to:
Colgate-Palmolive Consumer Information Service Free Post 55123 PO Box 38077 Wellington Mail Centre provided by this warranty are in Please note that the addition to other rights and remedies available to you as a consumer under applicable national laws, including the Australian Consumer Law and the New Zealand Consumer Guarantees Act. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. Version 01, August 2018 2018801 Made in China from imported and local components 10 13 14 15 16 17 18