FCC ID: PX8LRU-6100 ComFlex 600 Series DAS

by: Comba Telecom Ltd. latest update: 2014-01-24 model: LRU-6100

One grant has been issued under this FCC ID on 01/24/2014 (this is one of seven releases in 2014 for this grantee). Public details available include internal & external photos, frequency information, and manuals. some products also feature user submitted or linked instructions, password defaults, drivers, troubleshooting guides, & warrantee terms.
permalink for this FCC identifier
|
|
|   
eg for Slack usage
app s submitted / available
1 TempConfidential User Manual-Rev1 Users Manual pdf 4.02 MiB
1 Cover Letter(s) pdf
1 Cover Letter(s) pdf
1 ID Label/Location Info pdf
1 RF Exposure Info pdf
1 Test Report pdf
1 Test Report pdf
1 Test Report pdf
1 Test Report pdf
1 Test Report pdf
1 Test Report pdf
1 External Photos pdf
1 Internal Photos pdf
1 Test Setup Photos pdf
1 TempConfidential User Manual-Rev1 Users Manual pdf 4.02 MiB

frequency equipment class purpose
1 2014-01-24 2110 ~ 2155 B2I - Part 20 Industrial Booster (CMRS) Original Equipment

Application Forms

app s Applicant Information
1 Effective 2014-01-24
1 Applicant's complete, legal business name Comba Telecom Ltd.
1 FCC Registration Number (FRN) 0006794697
1 Physical Address 611 East Wing, No. 8 Science Park West Avenue, Hk
1 HongKong, N/A 510663
1 China
app s TCB Information
1 TCB Application Email Address h******@acbcert.com
1 TCB Scope B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
app s FCC ID
1 Grantee Code PX8
1 Equipment Product Code LRU-6100
app s Person at the applicant's address to receive grant or for contact
1 Name R****** G****
1 Title Director
1 Telephone Number +86 2********
1 Fax Number +86 2********
1 E-mail g******@comba.com.cn
app s Technical Contact
1 Firm Name GUANGZHOU GRG METROLOGY&TEST CO.,LTD
1 Name J****** C********
1 Physical Address 163 Ping Yun Rd,West of HuangPu Ave
1 Guangzhou, 510656
1 China
1 Telephone Number 86-20******** Extension:
1 Fax Number 86-20********
1 E-mail c******@grgtest.com
app s Non Technical Contact
1 Firm Name GUANGZHOU GRG METROLOGY&TEST CO.,LTD.
1 Name C******** L********
1 Physical Address 163 Ping Yun Rd,West of HuangPu Ave
1 Guangzhou, 510656
1 China
1 Telephone Number 86-20******** Extension:
1 Fax Number 86-20********
1 E-mail l******@grgtest.com
app s Confidentiality (long or short term)
1 Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:Yes
1 Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?:Yes
1 If so, specify the short-term confidentiality release date (MM/DD/YYYY format)07/22/2014
if no date is supplied, the release date will be set to 45 calendar days past the date of grant.
app s Cognitive Radio & Software Defined Radio, Class, etc
1 Is this application for software defined/cognitive radio authorization?No
1 Equipment ClassB2I - Part 20 Industrial Booster (CMRS)
1 Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant)ComFlex 600 Series DAS
1 Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application?Yes
1 Modular Equipment TypeDoes not apply
1 Purpose / Application is forOriginal Equipment
1 Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization?No
1 Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization?Yes
1 Grant CommentsPower output listed is per carrier at the antenna terminal (downlink) of an remote unit device. Emission Designator F9W covers both CDMA and WCDMA. This transmitter operates as a remote unit as part of a system along with host unit components as described in this filing, and excluding any other devices connected to the (downlink) output terminal of the host unit. Antennas installed for each remote unit must provide a minimum 64cm separation distance from all persons as described in this filing. The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures. RF exposure compliance is addressed at the time of licensing, as required by the responsible FCC bureau(s), including antenna co-location requirements of § 1.1307(b)(3). This grant is subject to the conditions of the limited waiver issued by FCC Wireless Telecommunications Bureau, as shown in this filing. Part of booster system used with FCC ID: PX8MU-6100.
1 Is there an equipment authorization waiver associated with this application?No
1 If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded?No
app s Test Firm Name and Contact Information
1 Firm Name Guangzhou GRG Metrology And Test Technology LTD.
1 Name G**** W********
1 Telephone Number 86203******** Extension:
1 Fax Number 86 20********
1 E-mail w******@grg.net.cn
Equipment Specifications
Line Rule Parts Grant Notes Lower Frequency Upper Frequency Power Output Tolerance Emission Designator Microprocessor Number
1 1 27 728 746 1.26 0.02 ppm G7D
1 2 27 746 757 1.26 0.02 ppm G7D
1 3 22H 869 894 1.26 0.02 ppm GXW
1 4 22H 869 894 1.26 0.02 ppm G7W
1 5 22H 869 894 1.26 0.02 ppm F9W
1 6 22H 869 894 1.26 0.02 ppm G7D
1 7 24E 1930 1995 1.26 0.02 ppm GXW
1 8 24E 1930 1995 1.26 0.02 ppm G7W
1 9 24E 1930 1995 1.26 0.02 ppm F9W
1 1 24E 1930 1995 1.26 0.02 ppm G7D
1 11 27 2110 2155 1.26 0.02 ppm F9W
1 12 27 2110 2155 1.26 0.02 ppm G7D

 