CDL-200L USER MANUAL Durable Door lock Metal body Additional number entry for secure password Multiple passwords can be registered Multi-level volume control / Selectable silence function Light-up buttons for visibility Emergency power function (9V battery) High-voltage protection/Fire protection/Anti-hack system Simple registration Remote control using BLE, ZIGBEE COMMAX Co., Ltd. Thank you for purchasing COMMAX products. Please red this manual before use. Commax is not responsible for any safety issues due to abnormal operation of the product Products specifications and components Indoor Names and Functions Sort Specifications No Name Specifications Opening method Rated voltage Emergency power Type of product High temperature sensing Material Password Smart key DC 6V DC 9V Out body In body Fire-proof, Temperature-sensitive form, None-KEY, Primary keylock / F-T-NK-M) Temperature sensor type 60 10 AL,ZN,ABS,PC AL,ZN,ABS,PC 4-12 digits (Up to 4 can be registered) It can register within 30 LR6 1.5V AA sized alkaline batteries 4 Battery cover This cover protects the batteries and the registration button. Indoor handle Used to open or close the door indoors. Alkaline batteries 8 (Separate purchase) Registration button(R) Used to register or change password or smart key Mortise Closes or locks the door Dead bolt
(Square locking type) It locks the door Latch bolt Stabilizes door on closing Alkalina AA battery Power source thst operates the door lock Double lock button
(Close button) Cna be used to lock the door so that it can not be opened from the outside. 1 2 3 4 5 6 7 8 Outbody Inbody Mortise & Stricker Screw Installation instruction User manual 8 Batteries Construction diagram 4 Smart key Outdoor shaft
*The components of the product may change depending on the installation environment. Outdoor Names and Functions No Name Specifications 1 2 3 4 5 Number plate Enter the number when registering or changing password. Battery warning light Turns on with an audible alarm at low voltage. Outdoor handle Emergency power terminal Smart key input unit It is Used to open or close doors from outdoors. In case the battery is completely discharged, you can use 9V battery then, the power will be on. It is the place where smart keys are recognized to open the door. You can open the door by registering the smart key or touching the registered smart key. This lock does not come with a physical key and in the rare event of failure, may require the destruction of the lock for removal and replacement. Safety Warning These warning are to ensure the secure operation of the lock. Carefully read the instructions below
* No unauthorized person should disassemble, repair or modify the device.
* This product is for indoor use.
* Please read the User Manual before useing product.
* Do not press the buttons with any sharp objects
* Change your access code from time to time for your safety.
* Do not impact the device.
* Be careful of leakage or rupture that may occur when inserting a battery in wrong direction.
* Prevent the device coming in contact with water
* when replacing a battery, change all the batteries with new alkaline batteries.
* Please wipe the product with soft, dry towels.
* Please keep product warranty card for after service.
* Do not use this product for other purposes than digital door lock function. 9V emergency battery
(Separate purchase) How to register and change password How to delete smart key Internal double lock setting Be sure to register your password with the door open. 1. Press
[registration] button 2. Press [1]button in the number plate of outdoor side 1. Press
[registration] button 2. Press [7]button in the number plate It is a function that can not open a door with a password or a smart key outside the door. Beep Open the battery cover and press [registration]button 3. Enter new password After entering the new password(4~12 digits), press * button and the confirmation tone sounds and registration is completed. Press the * button once more to end registration. Reference 1. When adding the password, repeat the above item 3 before the key pad turns off. 2. Up to 4 password can be registered Cautions 1. If you register a new password, the existing password will be automatically deleted. 2. Do not use consecutive numbers when registering your password. Beep Open the battery cover and press [registration]button 3. Press [#] button Press and hold the [#] button for 5 seconds to delete the registered smart key. Locking door from inside and outside Indoor Outdoor Press the [double lock] button on the inside Touch the keypad How to register smart key Open the door in outside 1. Press
[registration] button 2. Press [2]button in the number plate of outdoor side Method 1 Open the door by password 1. Enter password 2. Press [*]button Setting 1. While the door is locked, press and hold the [double lock]
button for 3 seconds If you press and hold the [DUAL LOCK] button for 3 seconds, the setting is completed with sound. How to release internally 1. Open the door by handle to release lock 2. Press the [double lock] button inside to dismiss double lock setting Deactivation from outdoor unit 1. Enter Password 2. Press [#], [9] button Touch the number plate and enter your password Press [#] then press [9], internal double lock is off with beep sound If you touch the smart key to be registered one by one, you will hear a confirmation sound every time you touch it. Registration is completed by clicking the [Registration]
button on the indoor side body. Method 2 Open the door with smart key 1. Contact smart key to smart key input unit Beep Open the battery cover and press [registration]button 3. Contact smart key to smart key input unit Reference 1. When adding the smart key, please repeat the above item 3 before the
[Number plate lamp] turns off. 2. Up to 30 smart keys can be registered. Cautions 1. When registering a new smart key, the existing smart key is automatically deleted. Touch the number plate and enter your password Press the [*] button, you will hear a confirmaion tone and then the door will open Registration authentication setting 1. Enter password 2. Press [#] button twice, press [8] button. Touch the number plate and enter your password Registration authentication Mode on/off When the registered [Smart Key] is touched to the smart key input part, a confirmation tone is heard and it opens when you open the door. Reference 1. If registration authentication mode is activated, first authentication by existing password should be done for the next step.
* Registration authentication is not activated if factory setting.
* To deactivate registration authentication, repeat the same procedure for activation Volume Adjustment Battery Replacement Alert Factory Reset Mode Deadbolt of indoor unit must be come out from mortise before setting If battery alert light is on on number plate or beep sounds ring, battery has to 1. Press [Registration] button. be replaced. All batteries must be replaced with new one at once. How to 1. Enter Password 2. Press [#] button Touch the number plate and enter your password 3. Press [3] or [6] to adjust volume
[3] for volume up
[6] for volume down Reference 1. Available total 8 levels of volume sound 2. If sound pause mode, numbers are only flicking without sound Sound Pause Mode Temporary silence function (1 time) regardless latest volume setting How to 1. Touch number plate and press [#]
2. Press [*] after password or, contact smart key to open the door. Reference Sound is back to the original volume if pause mode is operated once Burglar Alert If door to be opened by abnormal operation such as door gap break through, burglar alert rings with more than 80db noisy sound. How to deactivate burglar or temperature alert Remove batteries or [password + *], [Smart key touch]
* if temperature is too high, no deactivation. Caution 1. Lifetime of battery can be varied according to manufacturers, date of production, working condition. (Expected lifetime : 10 months assuming no wireless operation, AA type alkaline 8ea, 10 times per one day use) 2. If battery liquid leaks out, product can be damaged. Regular checking is recommended every 6 months. 3. Battery lifetime might be shortened if wireless module is activated. High Temperture Alarm Once extremely high temperature is detected (60 10), locker is automatically released to open the door with huge sound to secure users safety. Emergency Power When door can not be opened due to fully discharged battery. 1. Contact the terminals of 9V battery to emergency power outlet Press [Password] and [ * ] to open the door while contacting terminals of 9V battery to emergency power outlet. Open the battery cover and BEEP press [Registration] button for 5 secs 2. Enter123578951 when number plate lights on 3. Press [#] button for 2 secs. Factory default mode is completed with beep sound. Caution 1. All settings back to the default after factory reset including master information Deadbolt Jam alert When deadbolt is jammed during door open/close, alert sound of bee bee bee bee rings 3 times. 9V emergency battery
(sold separately) Caution 1.If no sound deactivation or door lock malfunction, product installed position has to be adjusted. Please contact your local installer or service provider. How to register/delete ZIGBEE Register 1. Press [registration] button for 5 seconds 2. Press [1]button twce then press [*]
To inform door open status during automatics lock setting, alert sound rings 2 times with each 15 seconds interval if door opened. Door Open Alert during automatic lock setting Self-Diagnosis Table by each LED number flicking 1. Press [registration] button for 5 seconds 2. Press [0]button twce then press [*]
Regulatory Compliance Beep Open the battery cover and press [registration]button Delete Beep Open the battery cover and press [registration]button Beep Open the battery cover and press [registration]button Delete Beep Open the battery cover and press [registration]button How to register/delete BLE Register 1. Press [registration] button for 5 seconds 2. Press [9]button twce then press [*]
1. Press [registration] button for 5 seconds 2. Press [0]button twce then press [*]
This product complies with standards established by the following regulatory bodies:
Federal Communications Commission (FCC) Industry Canada FCC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet ona circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/ TV technician for help. IMPORTANT ! Changes or modifications not expressly approved by the manufacturer could void the users authority to operate the equipment. FCC Radiation Exposure Statement The equipment complies with FCC Radiation exposure limits set forth for uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm Industry Canada This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the following two conditions:
( 1 ) this device may not cause interference, and ( 2 ) this device must accept any interference, including interference that may cause undesired operation of the device. This device complies with ISED radiation exposure limits set forth for an uncontrolled environment and meets the ISED radio frequency (RF) Exposure Guidelines. It is desirable that it should be installed and operated keeping the radiator at least 20 cm or more away from persons body. Canada, avis dIndustrie Canada (IC) Cet appareil est conforme aux normes RSS exemptes de licencedIndustrie Canada. Son utilisation est soumise aux deux conditions. suivantes : (1) cet appareil nengendre pas dinterfrences, et (2) cet appareil doit tolrer tout type dinterfrences, notamment les interfrences pouvant provoquer une utilisation non dsire delappareil. Cet quipement est conforme aux limites tablies par Industrie Canada en matire dexposition aux radiations dans un environnement non contrl. Cet quipement doit tre install et utilis avec une distance minimale de 20 cm entre le radiateur et votre corps.between the radiator and your body. To see the status of product by means of checking flicking number ACTION SELF-DIAGNOSIS Flicking ALL LEDs
- Anti-mischief alert and 1 minute pause Flicking LED number 2
- Error on password Flicking LED number 3
- Full of registered password Flicking LED number 4
- Deadbolt Jam Flicking LED number 5
- Burglar Alert Flicking LED number 6
- Unregistered password Flicking LED number 7
- Already registered address Flicking LED number 8
- Fire Alarm Flicking LED number 9
- Dual lock from Indoor unit Flicking LED number 0 Summary of how to use Function D efault Password registration/change 1234 Smart key registration None Delete all card Open the door indoors Close the door indoors Open the door outdoors
[Registration] [1] Password to register [*] [*]
[Registration] [2] Smart key touch to smart key input unit
[Registration]
[Registration] [7] button [#] button More than 5 seconds Turn down the doorlock handle Press the [Doublel Lock]
Password: Touch the Number Plate Password [*]
Smart key: Smart key touch to smart key input unit Close the door outdoors After closing the door, Touch the Number Plate Set registration authenitication mode Off Password [#] [#] [8]
Internal dual lock LED setting Password [#] [#] [5]
Double lock setting Off Hold the [Double lock] of indoor doorlock for 3 seconds Release internal Double lock 2. Press the [Double lock] of indoor doorlock 1. Turn down the indoor doorlock handle Etiquette mode function
[#] Enter password [*]
3. Password [#] [9]
Buzzer volume setting Release alram sound Volume up: Password [#] [3]
Volume down: Password [#] [6]
Indoor: Remove the battery Register and delete master password Register and delete master card Delete all master passwords and cards Outdoor: Password [*]
* Without registered master password Registration: [Registration] [1] [Double lock] [#] 5times
[New master password] [*]
* When there is a registered master password Registration: [Registration] [1] [Double lock] [#] 5times
[Master password] [*] [New master password] [*]
D elete: [Registration] [1] [Double lock] [#] 5times
[Master password/9635741] [#] [1] [#]
* Without registered master password Can't register
* When there is a registered master password Registration: [Registration] [1] [Double lock] [#] 5times
[Master password] [*] [New master card] [*]
D elete: [Registration] [1] [Double lock] [#] 5times
[Master password/9635741] [#] [2] [#]
D elete: [Registration] [1] [Double lock] [#] 5times
[Master password/9635741] [#] [3] [#]
CDL-200L_CAN