DDL .indd 1 2016. 5. 2. 3:43 Overview Robust Door Lock Body KS & KC authentication give guaranted Quality and insured Product Satisfaction. Metalic Diecasting Design Metal body is durable to fire and shock from outer side hazard and damage. Auto Lock/ Re Lock/Double Lock Function User Friendly Function give Safety and easy usage. Dummy Number Functions give high level safety. Dummy Number & Real number combination give high level password. Multi-registrations for pin-number & electronic key It is easy to register the pin-number(up to 4) and you can also register the electronic key(up to 30 ea). it available to Traffice card/credit Card,too. Multi-level volume control / mute optional Function User can easily select 7level Volumne Control. Light Button indicate in the dark space You can easy to use the device using light keypad buttons. Emergency Power Function (9V square battery) Emergency power working even if the batteries run out completely. Anti high-voltage / anti fireproof / anti-hacking system It is very safe for using anti high-voltage and anti-hacking system. Also if the temperature is higher than certain temperature, the door will be open automatically with warning sounds under the fire. Digital Door Lock COMMAX DDL .indd 2 2016. 5. 2. 3:43 Safety Cautions Dont install, repair or disassemble the device randomly. This device is suitable for home safety level, other condition will not be guarante quality. Please read operation manual Carefully. U s e r M a n u a l Dont push or insert the button with drill or pin. Change the pin-number regularly for the safety. Don't heavy damage on door lock. Do not insert the batteries reversely. it will be cause some burst or leakage from batteries . Dont put water into the device. when change battery, please use all new alkaline battery. When you clean the device, please use the dry towel. Do not use any other purpose for Door lock. www.commax.com DDL .indd 3 2016. 5. 2. 3:43 CONTENTS Specification Parts Nmae How to use Easy Function
(option) Emergency Alarm Function Setting Pin Number Setting Smart Key Setting BLE(Smartphone) Delete setting Smartkey Delete setting BLE Open the gate(Keypad) Lock the gate(Outside) Open the gate(Inside) Lock the gate(inside) Force Lock Status Autolock Setting Manual Setting Sound Pause Function Volume Control Function Dual Authentication &Registration on/off Built in Remocon Setting Heat Warning Intruder Alarm Warning Mischef and 1min stop function Deadbolt(mortise) Error Alarm Battery Replacement Warning Emergency Power Emergency Key(key type) Breakdown Cause and Solution Consumer Protection Rules Product Warranty Digital Door Lock COMMAX Install Condition Access Methods Emergency Power Temperature Alarm Wireless Devices Outside Body Battery 4pcs Warning Sticker Screw Hole Paper Smartkey 2pcs DDL .indd 4 2016. 5. 2. 3:43 Specifications Product Standard Division Features Install Condition Normal Fire Door Door thickness 40mm ~ 50mm Pin Number 4~12 digit number combination(Up to 4 pin number) Access Methods Smart key Up to 30 keys Smarphone Remocon Option Option on i t a l l a t s n i e r P d n a e g a s U Rated Voltage Emergency Power DC 6V DC 9V LR6 1.5V AA Size Alkaline Battery, 4 pcs Alkaline battery(Optional) Product Type Fireproof type, Temperature sensor type, Key type, Master key door lock(D-NF-T-K-M) Temperature Alarm Temperature Sensor 72 5
(Lab Conditions) 62 5 (Normal Conditions) Material RF Standard Item RFID External Enclosure Al, Zn, ABS Internal Enclosure Al, Zn, ABS Frequency Channel Modulation Antenna power (field strength) 13.56Mhz 1ch 1ch ASK FSK Under 93.5dBuV/m@10m Under 10mW Wireless Devices 447.275Mhz Features Outside Body Inside Body Mortise Striker Screws User manual
(Warranty) Battery 4pcs Screw Hole Paper Smartkey 2pcs Outdoor shaft www.commax.com DDL .indd 5 2016. 5. 2. 3:43 Parts Name Outside Body Name & Function 9V Emergency Battery
(Sold Seperately) No No Name Features Key Buttons Register or change the pin number. Open the door with registered pin number. Battery Alarm Open/register the electronic key. Smartkey Access Point Smartkey access point for open gate. By Contracting smartkey open the door or register smart key. Outside Handle handle can open or close the door. Emergency Power Supply Terminal When battery fully discharged, contact 9V battery and power on emergency power working. Digital Door Lock COMMAX DDL .indd 6 2016. 5. 2. 3:44 Inside Body Name & Function e g a s U No Name Features Battery Cover Cover for battery and buttons for registration of pin number & electronic key. Link Pack Receiver (CDL-447RM, option) Register Button Use registration or change the pin number or electronic key Mortise Dead Bolts Lock or close the door for installing side of door. Lock the door to door frame. Wrench Bolts Prevent to shake the door. Sub Wrench Bolts Check for Door open or Close. Alkaline AA Battery Battery for main power Manual Lock Button Lock the door under manual mode Inner Handle Open or close the door from inside. www.commax.com DDL .indd 7 2016. 5. 2. 3:44 How to use Setting the Pin-number Caution Please set the pin number while you open the door. Open the inside [battery cover],push the[Register]Button and hear "Beep"
sound shortly. Outside Check outside light on [Keypad]
push the button NO . Outside Set the pin number 4 to 12 digits. Outside Push the [ ] button make "Beep" Sound and succeed registration One more push the [ ] button and completed registration. Note Add the other pin-number, you repeat , until turn off the lights on keypad.(Pin number can be registered up to 4 pin numbers. Caution The registration will be canceled when you do not push any numbers for 10 seconds after push the registration button. If you register new pinnumbers, old one will be deleted automatically. Digital Door Lock COMMAX DDL .indd 8 2016. 5. 2. 3:44 e g a s U Setting Smart Key Caution Newly registered smart key or re-registred, please register at a same time. other card not possible except provided card. Open the battery cover, Push the registration button once then you can hear Beep sound. Outside Check outside light on [Keypad]
push the on the Keypad, direction Dimming Outside
[Smart key]close up on [smart key input]
when succeed registration, sound beeping Inside Push the [Register]button, it completed Registration. Note if you want to add smartkey, it available max 30keys. if you want more add up smartkey please repeat no process before turn off [Keypad]light. Caution it canceled [Register]button if smartkey not attach smartkey input. if new smartkey register (Process , , , ), previous register smart key will be automatically deleted. www.commax.com DDL .indd 9 2016. 5. 2. 3:44 DDL .indd 10 2016. 5. 2. 3:44 Delete setting Smartkey Open the inside [Battery cover]
push the[Register] Button and hear "beep" sound shortly. Outside Chekc outside [Keypad] lightning on, Push the Button, light on [ ]Button. Outside Push the [ ]during 5sec. it makes 'Beep"sound and delete entire smartkey information. e g a s U 5sec www.commax.com DDL .indd 11 2016. 5. 2. 3:44 How to use Delete Setting BLE
(CDL - 3PBR Model Case) Open the inside [Battery cover] push the [Register] Button and hear
"Beep" sound shortly. OutSide Check outside light on [Keypad] push the button No press No Button and LED Light on [ ]
OutSide Press button 5sec [ ]
Beep sound and delete whole BLE Regitstered key. 5sec open the gate (Keypad) Method1 Key pad openning Touch [Keypad], input [Password]. Push the [ ]button and belling beep sound Door will be released. Note Dummy number function will be add up head or tail to original password. dummy No+original password original password+dummy No
(for preventing from other person cheating password) Digital Door Lock COMMAX Method 2 Method 3 Method 4 DDL .indd 12 2016. 5. 2. 3:44 Open the gate (Smart Key) Method 2 Smartkey Opening Registered [Smart Key]close to
[Smart key] access point. Beep sound and open the Gate. e g a s U Note In case of Credit card/Traffic card, touch key first and then light on
[Keypad] and close to access point, it will be open the gate. Method 3 BLE(smartphone)Opening (CDL - 3PBR Model type) Shake on [BLE (Smartphone)]
on the access point. Beep sound and open the oate. Method 4 Remocon opening (option) Push the [OP/CL]button on the Remocon and open the gate. www.commax.com DDL .indd 13 2016. 5. 2. 3:44 How to use Lock the gate (Outside) Method 1 Auto Locking Closing the door and lock the door after 2second automatically. 2sec Method 2 Manual Locking Touch the [Keypad], door will be lock. Method Method Open the gate Method 1 Pull the inside handle Just pull the handle, open the door easily. Cautio n Do not use or install outside dragging type door. Digital Door Lock COMMAX Releasing Push the handle from inside, Force Locking will be released. DDL .indd 14 2016. 5. 2. 3:44 Lock the gate (inside) Method 1 Auto Locking Closing the door and lock the door after 2 second automatically. Method 2 Manual Locking Push the inside
[double lock] button, door will be manual locking. 2sec e g a s U Not e Manual locking push the [double locking],gone to Locking status "beep"
noise and entered Double locking status. Force Lock Status Force Locking - Impossible by password, Smarphone, Smartkey from outside. Method Enther Lock Status Push the [Double Lock] 3sec, beep souding and enter Force Locking. Releasing Pull the handle from inside, Force Locking will be released. 3sec www.commax.com DDL .indd 15 2016. 5. 2. 3:44 Easy Function (option) Autolock Setting This function is Autolock setting Autolock Setting Open the door status Please check beside mortise Pop up. Touch the ouside
[Keypad]
Input password and push the[ ]
button twice. Push the No[4] and complete Beeping and setting Autolocking. Manual Setting This function is Manual Lock setting Manual Lock setting Open the door status Please check beside mortise Pop up. Touch the ouside
[Keypad]
Input password and push the[ ]
button twice. Push the No[7] and complete Beeping and setting Autolocking. Note Factory default is Auto lock setting. Digital Door Lock COMMAX This function for 1time mute for preventing beeping. Method Touch outside [keypad]and push the [ ]
This function for Volume Level control function. (closing door status available) Method Please check beside mortise Pop up. DDL .indd 16 2016. 5. 2. 3:44 Sound Pause Function This function for 1time mute for preventing beeping. Method Touch outside [keypad]and push the [ ]
Password: input password and push the [ ]button Card: Card access the sensor BLE(Smartphone) : BLE access and open the gate. e g a s U Push the No[4] and complete Beeping Note This function is just 1time, next time back again beep sound status Volume Control Function This function for Volume Level control function. (closing door status available) Method Volume coltrol by 7 level. Push the No[7] and complete Beeping Please check beside mortise Pop up. Touch the ouside
[Keypad]
Input password and push the [ ]
button twice. Push the No[3] or No[6] button on the [Keypad]
Note push the keypad of No[3] button volume up. No[6] button volume down. when enter Stop volume function keypad Blink www.commax.com www.commax.com DDL .indd 17 2016. 5. 2. 3:44 Easy Function (option) Autolock Setting This function is Dual authentication and registration on / off This function is Built in remocon setting. (for only Built remocon included model) Dual Authentication on/off Touch the ouside
[Keypad]
Input password Push the[ ]
button twice. Push the No[1] and complete Beeping and setting Autolocking. Open the inside
[Battery cover] push the[Register] Button and hear "Beep"
sound shortly. Registration on / off Touch the ouside
[Keypad]
Input password Push the[ ]
button twice. Push the No[8] and complete Beeping and setting Autolocking. Note Dual authenfication mode can open Smart key and password together. Regstration mode can open previouse password input. each process will be off by same process (sound : bee~leek) Factory default is Dual Authentication and Registrtion off status. Open the inside
[Battery cover] push the[Register] Button and hear "Beep"
sound shortly. Digital Door Lock COMMAX DDL .indd 18 2016. 5. 2. 3:44 Built in Remocon Setting This function is Built in remocon setting. (for only Built remocon included model) Remocon on e g a s U Push the No[1] and complete Beeping Open the inside
[Battery cover] push the[Register] Button and hear "Beep"
sound shortly. Push the No[3]
button and indicate Antenna icon LED. Push the [OP/CL]
button on the Remocon. Push the inside
[Register]button, it completed Remocon setting Note Add more remocon, please repeat no 2 process before light blink off
(max 5 remocon available) Caution Push the [Register]button and not link with Remocon, it will be canceled remocon setting. New remocon Setting before Remocon will be deleted. Push the No[8] and complete Beeping Remocon off Open the inside
[Battery cover] push the[Register] Button and hear "Beep"
sound shortly. Push the No[8] button Push the [#] button 5sec, "beep"sound and remocon will be off status. www.commax.com DDL .indd 19 2016. 5. 2. 3:44 Emergency Alarm Function Heat Warning When a fire is detected, a high temperature of about suspected (62 5), automatically releases the locked state with strong beeps for safety. Heat Warning Abnormally in the door is locked
(For example: forcely open the gate) occurs when the door open condition is detected Beep noise makes 80 db (db) beeper. Turn off heat warning & Intruder alarm Opened or locked, when the dead bolt (square clamp) of the indoor unit body is normally taken out, or do not enter "beep, beep beep, beep" warning sound occurs three times. Remove battery or input [password] or attach [smart key] , it will be turn off warning and alarm. When high temperrature status, it will be not turn off status. please cool down temperature. Turn off alarm Battery icon light on the Keypad or make sound "bleek bleek bleek", please change battery. all battery change required. Caution In case of inside body recieve sunlight, it will be warning and alarm. so, dual authentication will be turn off automatically Warning mischief and 1 minute stop function If input not registered [password] or [Smart Key repeatedly entered five times l stop operating 1 minutes with alarm. Mistake input 5 times??
Digital Door Lock COMMAX DDL .indd 20 2016. 5. 2. 3:44 Deadbolt(mortise)error alarm Opened or locked, when the dead bolt (square clamp) of the indoor unit body is normally taken out, or do not enter "beep, beep beep, beep" warning sound occurs three times. Deadbolt
(Mortise) e g a s U BBBB Caution If sound alarm countinuos or not workging properly. it required reallocation door lock position, please contact installer or door lock professional company. Battery Replacement Warning Battery icon light on the Keypad or make sound "bleek bleek bleek", please change battery. all battery change required. Bleek Bleek Bleek. Caution Do not use mixed with used battery and New battery , Please change all battery to new ones. Caution Wireless module use battery consumption, Battery recycle will be more shorthen. www.commax.com DDL .indd 21 2016. 5. 2. 3:44 Emergency Alarm Function Emergency Power Not e Batteyr gone, impossible open the door status. If the product does not operate normally, check the following check point first. Buy 9V Battery. 9v battery attach Emergency Power supply terminal. Press the
[ ]button. Input
[Password]. Push the [ ]
Button again and it beep and unlock. No Power No Change Password No open the door though push the
[ ]button Password / Smart key authentication success but no open the door keep going alarm Beleek x3 warning sound. No enter Auto Locking Digital Door Lock COMMAX DDL .indd 22 2016. 5. 2. 3:44 Break down cause and solution If the product does not operate normally, check the following check point first. Problem Solution Remarks No Power
- Please check battery status bad or gone power and check battery input direction
- please change new 4 alkaline Battery. e g a s U Push the [ ]
and it beep and No Change Password
- Again password register / repeat input.
- Please input password short Beepsound one by one.
- please check passwor input correctly No open the door though push the
[ ]button
- When input password, keypad light off, it will be not change password , presss the [ ]button and check keypad light on, input password again.
(if didnot input password within 7sec, it will be canceled.) Password / Smart key authentication success but no open the door
- Please try 9V emergency power(square type)
- Lock can may broken. please contact installer. keep going alarm Beleek x3 warning sound.
- Beep indicating the battery replaced. if you heard this alarm, please replace all new 4pcs battery. No enter Auto Locking
- Please reset automode.
- Sound occurs the batteries discharge and does not work. please change all new battery Drag the handle and door will be 8 Page 8 Page 22 Page 21 Page 16 Page www.commax.com DDL .indd 23 2016. 5. 2. 3:44 Purchase (installed) Date Please keep this document for full service must present this warranty. 1) Warranty for this product is the warranty benefits to the contents listed in the warranty. 2) The warranty period is calculated from the date of purchase, so please obtain a base purchase date. Consumer Protection Rules COMMAX conducted a guarantee of the product as shown below each item, depending on the consumer compensation regulations. Please install the product can not be installed by a professional installer or authorized installer to install receive A / S if faulty. Emergency Power If the product fails within the first year after purchase (the warranty period), you get the free service only. If the warranty period will be shortened half period by commerical usage. Consumer Damage Type Compensation within Warranty after warranty Functional defects in normal use occurred in 10 days Functional defects in normal use occurred in 1month Product Exchange Product Exchange Serviceable same fail 3times again same file 4times again Repair free Product exchange Repair charge Repair charge No Serviceable When repair parts for repair but impossible
(within the parts holding period)) When repair parts are not impossible to repair (parts within the retention period) Product Exchange Product Exchange Depreciation and exchange Depreciation and exchange Paid Service 1. For non-failure If it is not subject to failure, it will be service charge. Please read the instruction manual. Installation issue on non-malfunction. Force damage on the device for lost password. 2. If the consumer fails to negligence User Handling of abuse or inappropriate repair, modification and trouble occurs. Non official installer or non professional person installed and make trouble. Drop or make damage by cause of fault or error. 3. etc If any trouble occurs due to natural disasters
(lightning, fire, salt damage, flood, etc.) If the end-life of the consumable parts (batteries, etc.) normal case consumer receive within 15month(including distribution period) Digital Door Lock COMMAX DDL .indd 24 2016. 5. 2. 3:44 If the product fails within the first year after purchase (the warranty period), you get the free service only. Product Warranty Product Name Product Number Purchase (installed) Date 20 year month days Customer's Name Telephone Address Installer Company Telephone Address Installer's Name e g a s U Please keep this document for full service must present this warranty. 1) Warranty for this product is the warranty benefits to the contents listed in the warranty. 2) The warranty period is calculated from the date of purchase, so please obtain Depreciation and a base purchase date. Depreciation and Non official installer or non professional person installed and make trouble. normal case consumer receive within 15month(including distribution period) www.commax.com DDL .indd 25 2016. 5. 2. 3:44 FCC Statement 15.19:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 15.21:
Note: The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the users authority to operate the equipment. 15.105(b):
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. Disclaimers The manufacturer, importer, and distributor shall not be liable for damages including accidental and personal injury due to the improper use or operation of this product. The information in this user manual was written based on current product specifications. The manufacturer, iriver Limited, is adding new complementary features and will continue to apply new technologies in the future. Product specifications may be changed without prior notice. iriver is not responsible for data loss due to product use. Exposure statement The transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body. www.commax.com DDL .indd 27 2016. 5. 2. 3:44 MEMO Digital Door Lock COMMAX DDL .indd 26 2016. 5. 2. 3:44 MEMO O M E M www.commax.com DDL .indd 27 2016. 5. 2. 3:44 DDL .indd 28 2016. 5. 2. 3:44