R12 User Manual / Installation Compology Instructions The Basics ID LABEL Turning On Turning Off STATUS INDICATOR LIGHT Sensor Good Sensor Error (Check Logs) CAMERA FLASH MOUNTING POINTS Main Menu 1. Login 2. Click Icon 3. Main Menu Tasks Start here to complete maintenance tasks or installs List View View of maintenance tasks in a list Map View View of maintenance tasks on a map New Install Create a new bin and assign a sensor List View Map View New Install Sensor Tools Tap phone to sensor to interact and get info Logs View diagnostic info on a sensor On/Off Turn sensor on or off Verify Image See the latest image from a sensor Logs On/Off Verify Image New Install 1. ENTER BIN INFORMATION ID Enter number/name on outside of bin Size Enter the size of bin in cubic yards Organization Select the organization for this bin Content Select the type of material in container CLICK & HOLD IMPORTANT: You will need to select an organization if you are assigned to multiple. Make sure you select the correct one!
Position flat over sensors angled camera surface as shown 2. CHOOSE SENSOR TYPE 3. TAP PHONE TO SENSOR TO ACTIVATE ID of the sensor waiting to be assigned to the bin. Tapping any sensor will turn on or off that sensor and change the ID 4. VERIFY GREEN IMAGE
& NO ERRORS 5. COMPLETE If new image does not appear within 15 minutes:
1. Restart the current sensor by tapping sensor to turn off and then on 2. Wait for new image 3. If no new image appears, try new sensor IMPORTANT: Do not install sensor if new image does not appear If you see Sensor GPS Error:
1. Move to a location where you can see the sky, 2. Restart current sensor and wait 3. for new image If GPS error remains, try new sensor IMPORTANT: Do not install sensor with GPS error. Turning Sensor On/Off On/Off will be used to turn a sensor on or off when not in a task. You can use it to restart a sensor you want to check. TURNING ON Wait 5-10s, blue light will blink slowly 5X, and then flash a blue light every 2s during startup sequence Position flat over sensors angled camera surface as shown DING!
IMPORTANT: Make sure any sensors in your bag or inventory are OFF and all sensors you are installing into bins are ON. Pay careful attention to the indicator lights. TURNING OFF Immediately, yellow light will blink 10X very quickly and then turn off Checking Sensor Logs Position flat over sensors angled camera surface as shown DING!
Green = Good Red = Error Most common errors:
MODEM_CONNECT (cannot get cell signal). In this situation, restart sensor and try again before replacing GPS_LOCK (cannot get GPS signal). Move to a location where you can see the sky and try again before replacing sensor SYSTEM will be an error if anything has failed Logs should be used to identify root issues when a sensor is not uploading an image. It can only be taken after a sensor has gone through its startup sequence and the indicator light is no longer flashing. Verify Image Verify Image should be used after a sensor is restarted to check to see if an image was uploaded successfully SENSOR ID Position flat over sensors angled camera surface as shown DING!
VERIFY GREEN IMAGE &
NO ERRORS Maintenance Viewing Tasks Start here to complete maintenance tasks List View When a task is assigned to you, it will appear on this list. Tasks will stay here until it is completed, skipped or removed by a Compology Manager Task Notes Each task will have instructions for you to follow Each individual task to complete is listed here List View Task Details Finding the Sensor Find the last known location of the sensor 1. Select task you want to complete from the List View 2. Scroll down and select Get Directions. Google Maps will automatically appear 3. Select Directions 1. Select Task 2. Get Directions 3. Google Maps Cant find the Container If you arrive to the location provided by Google Maps and the container is not there, or you cannot access the location:
Select the task for that specific sensor Scroll down to the bottom of the task Select I Cant Complete This Task 1. 2. 3. 4. Mark all boxes that apply 5. Select Submit and Skip Task 1. Select Task 2. Scroll down Youve located the container?
CONTINUE TO NEXT PAGE Select options, Skip Task Troubleshooting the sensor Is the sensor missing or physically damaged?
Use task tools to investigate issue NO YES Replace sensor. Go to next page To investigate-
1. Turn sensor off & on again 2. Check for green logs 3. Check for new image Did the sensor post green and get a new clear image?
YES NO Select Ive Completed This Task Replacing a sensor Procedure to replace a sensor In the task, select uninstall Turn off sensor 1. 2. 3. Complete Uninstall - Continue to next page 1. Select Uninstall 2. Uninstall instructions 3. Complete Uninstall Position flat over sensors angled camera surface as shown Replacing a Sensor (continued) Procedure to replace a sensor Click Yes, Install button on swap window
*If window does not appear, click install in task*
1. Select new sensor type 2. 3. Turn on new sensor If sensor flashes green light, select complete 1. Select Sensor Type 2. Activate sensor 3. After green light, select Complete Position flat Position flat over over sensors sensors angled angled camera camera surface as surface as shown shown After Completing a Task RETURNING SENSORS All damaged or malfunctioning sensors must be marked with tape and shipped back to Compology HQ Address:
1045 Bryant Street, Suite 101, San Francisco, CA 94103 Fedex Account to charge will be provided by Compology Physical Install
& Uninstall Overview Roll-Off Install Instructions 1. COMPLETE NEW INSTALL WITH COMPOLOGY TECHNICIAN APP 2. ATTACH SENSOR TO SHIELD WITH SCREWS 3. PLACE SENSOR IN BIN AND HOLD IN PLACE USING BAR CLAMP See Mounting Locations document for positioning M5x12 Bryce Security Screw (3X) M5 SS Lock Washer (3X) 4. DRILL 6 HOLES USING THE 3/16 DRILL BIT BAD IMPORTANT: Do not drill holes at the edge of the box beam. Only drill holes where there is open space behind a single thickness of material Preferred hole location shown. If these locations are not available shift up or down, but try to balance 3 on each side with more towards the top. 5. INSTALL 6 3/16 RIVETS WITH RIVET GUN 6. ADD STICKER TO OUTSIDE OF BIN IMPORTANT: If a rivet does not seat properly, or there is a big gap between the shield and the bin at a given rivet location, add more rivets elsewhere. 3/16 Dome Head SS Rivets (3X) Sticker Front-Load Install Instructions 1. COMPLETE NEW INSTALL WITH COMPOLOGY TECHNICIAN APP 2. PLACE MAGNETIC TEMPLATE ONTO BIN 3. DRILL 3 HOLES USING 3/16 DRILL BIT See Mounting Locations document for positioning 3/16 Drill Bit IMPORTANT: Top 3 holes for R12 4. EXPAND HOLES USING STEPPED DRILL BIT 5. MOUNT SENSOR 6. ADD STICKER TO OUTSIDE OF BIN Bryce M5x12 Security Screw (3X) M5 Flat SS Washer(3X) M5 SS Lock Washer (3X) Neiko 10182A Titanium Step Drill Bit Sticker Roll-Off Uninstall Instructions 1. TURN OFF SENSOR (VERIFY YELLOW BLINKING LIGHT) 2. HOLD SENSOR IN PLACE USING BAR CLAMP 3. DRILL OFF HEAD FLANGES OF RIVETS USING #3 DRILL-POINT COUNTERSINK
#3 Drill-point Countersink 4. USING A HAMMER AND 5/32 PUNCH, PUSH RIVETS THROUGH HOLES 5. REMOVE SCREWS & SENSOR (IF POSSIBLE) 5/32 Punch Front-Load Uninstall Instructions 1. TURN OFF SENSOR (VERIFY YELLOW BLINKING LIGHT) 2. REMOVE SCREWS & SENSOR General Disclaimers NOTICE:
This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
1. 2. this device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. NOTICE:
Changes or modifications made to this equipment not expressly approved by (manufacturer name) may void the FCC authorization to operate this equipment.