PRODUCT User Manual Confidex Viking Slim Reliable industrial grade Bluetooth Low Energy beacon for industrial identify, sense and locate applications. ELECTRICAL SPECIFICATION Device type Bluetooth Low Energy beacon, Battery powered Wireless interface protocol Bluetooth 4.2 NFC: ISO/IEC 14443A Compliancy (Declaration of Conformity) Europe (CE), USA (FCC), Canada (IC), Japan (MIC), Australia/New Zealand (ACMA), South-Korea (KC), Russia (EAC), Ukraine (UkrSEPRO), Brazil (ANATEL) Operational frequency ISM: 2401 - 2481 MHz NFC: 13,56 MHz System-on-Chip Nordic Semiconductor NRF52832 Memory configuration 512 kB FLASH, 64 kB RAM Configuration interface Over NFC interface with Confidex Runestone mobile app
(available for android mobile phones in Google Play store) Sensors*
Built-in temperature sensor (integrated on SoC) Sensitivity
-96 dBm sensitivity (Bluetooth Low Energy) Read range**
Up to 200 m / 650 ft. Measured on and off metal. Battery type (total capacity) Replaceable CR2477 (1000 mAh) coin battery Lithium Manganese Dioxide chemistry Applicable surface materials Can be attached to any surface
* Temperature sensor is located inside the plastic housing, which limits real time measurement of the ambient temperature. Sensor calibration is available as additional service.
** Read ranges are measured in laboratory environment and there can be some variation in real application. MECHANICAL SPECIFICATION Encapsulation IP68, high quality PC/ASA Weight 50g Delivery format Single, 50 units per box
(delivered radio OFF due to IATA regulations) Tag dimensions 74,5 x 32 x 14,5 mm / 2.95 x 1.26 x 0.57 in (M5 size hole) ENVIRONMENTAL RESISTANCE Operating temperature
-20C to +60C / -4F to +140F EN 60068-2-14: 2009, Test N: Change of temperature Water resistance Good, tested 5 hours in 1m deep water (IP68) Vibration resistance EN 60068-2-6: 2008, Test Fc: Vibration, 10G EN 60068-2-27: 2009, Test Ea: Shock, 20G ESD immunity 8 kV according to EN 61000-4-2 (air discharge) 4 kV according to EN 61000-4-2 (contact discharge) Chemical resistance ***
No physical or performance changes in:
- 168h Motor oil exposure
- 48h Salt water (salinity 10%) exposure
- 48h Sulfuric acid (10%, pH 2) exposure
- 48h NaOH (10%, pH 13) exposure Generally good resistance with moderate concentrations of acids, alcohols, alkalis, detergents, and cleaners. Acetone should be avoided. Expected lifetime****
3-4 years with typical operating parameters the best recommendations;
***Values are resistance against environmental conditions depends on the combination of all influencing factors, exposure duration and chemical concentrations. Thus, products final suitability for certain environmental conditions is recommended to be tested. Contact Confidex for more specific information.
**** Beacon lifetime is optimized for long term use, and is highly affected by operating mode parameters, accelerometer usage and ambient temperature. Configured TX power level and advertisement interval have influence on lifetime. 1/3 CONFIDENTIAL Confidex 2021 contact.BLE@confidex.com www.confidex.com OPERATING MODES Confidex Viking beacon utilizes Eddystone open standard frame format and/or iBeacon protocol ensuring implementation on a wide range of straightforward Bluetooth Low Energy devices. Confidex Viking Classic comes with standard parameters by default. It can be factory configured with customer specific parameters to support any 3rd party system. Confidex Viking can also be personalized with a custom label to ease the tag identification in the field. Following Eddystone frame types are supported:
like Eddystone-UID frame broadcasts 16-byte Beacon ID composed of a 10-byte namespace and a 6-byte instance. Eddystone-URL frame broadcasts a URL using a compressed encoding format. Eddystone-TLM frame broadcasts telemetry and information, temperature. Eddystone-EID frame broadcasts an encrypted ephemeral identifier that changes periodically. Eddystone-EID frame operating mode requires service for resolving the ephemeral ID. Please contact Confidex for more information. iBeacon advertise 16 bytes UUID, 2 bytes Major, and 2 bytes Minor. voltage battery INSTALLATION INSTRUCTIONS Confidex VikingTM can be attached with several fixing methods:
3. High performance acrylic adhesive When mounting the tag with adhesive, clean and dry the surface for obtaining the maximum bond strength. Ideal application temperature is from +21C to +38C (+70F to
+100F), bond strength can be improved with firm application pressure and moderate heating from +38C to
+54C (+100F to +130F). Installation at temperatures below +10C (+50F) is not recommended. ORDER INFORMATION 300XXXX Confidex Viking Lite
- With default configuration and parameters 300YYYY Confidex Viking Classic, pre-configured
- With customer specific configuration and parameters
(see the personalization form for more details) 300ZZZZ Confidex Viking Classic Sample Kit
- Contains 5 pcs of 300XXXX Availability: Please contact Confidex Smart Industries Sales at www.confidex.com/contact-us For additional information and technical support, please contact us in contact.BLE@confidex.com DISCLAIMER THE MATERIALS, PRODUCTS AND SERVICES ARE SOLD SUBJECT TO ITS STANDARD CONDITIONS OF SALE, WHICH ARE INCLUDED IN THE APPLICABLE DISTRIBUTOR OR OTHER SALES AGREEMENT. ALTHOUGH ANY INFORMATION, RECOMMENDATIONS, OR ADVICE CONTAINED HEREIN IS GIVEN IN GOOD FAITH, CONFIDEX MAKES NO WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, (i) THAT THE RESULTS DESCRIBED HEREIN WILL BE OBTAINED UNDER END-USE CONDITIONS, OR (ii) AS TO THE EFFECTIVENESS OR SAFETY OF ANY DESIGN INCORPORATING ITS PRODUCTS, MATERIALS, SERVICES, RECOMMENDATIONS OR ADVICE. EXCEPT AS PROVIDED IN CONFIDEX STANDARD CONDITIONS OF SALE, CONFIDEX AND ITS REPRESENTATIVES SHALL IN NO EVENT BE RESPONSIBLE FOR ANY LOSS RESULTING FROM ANY USE OF ITS MATERIALS, PRODUCTS OR SERVICES DESCRIBED HEREIN. Each user bears full responsibility for making its own determination as to the suitability of Confidex products, materials, services, recommendations, or advice for its own particular use. Each user must identify and perform all tests and analyses necessary to assure that its finished systems incorporating Confidex products, materials, or services will be safe and suitable for use under end-use conditions. Nothing in this or any other document, nor any oral recommendation or advice, shall be deemed to alter, vary, supersede, or waive any provision of this Disclaimer, unless any such modification is specifically agreed to in a writing signed by Confidex. 1. Mechanical fixing Screw CAUTION Mechanical fixing is recommended to be used in every application that includes risk for high mechanical stress or low temperature during tag fixing. Screw size M5 is to be used for fixing.
Professional equipment;
Equipment for use in locations where it is unlikely that children will be present. 2. Mechanical fixing Cable tie Plastic or metallic cable ties can also be used for fixing Confidex VikingTM. Maximum width of cable tie is 4 mm. 2/3 CONFIDENTIAL Confidex 2021 contact.BLE@confidex.com www.confidex.com Canada: Industry Canada (IC) Statement IC Notice to Users English/French in accordance with RSS GEN Issue 3:
This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to the following two conditions:
1. this device may not cause interference, and 2. this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec Industrie Canada RSS standard e empts de licence s . Son u lisa on est soumise Les deu condi ons suivantes:
1. cet appareil ne peut pas provoquer dinterf rences et . cet appareil doit accepter Toute interf rence, y compris les interf rences qui peuvent causer un mauvais fonctionnement du dispositive This Class B digital apparatus complies with Canadian ICES-003. Cet appareil num rique de la classe B est conforme la norme NMB-003 du Canada. Federal Communications Commission (FCC) Statement (USA) FCC PART 15 STATEMENTS FOR USERS MANUAL THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS. (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures: