1 of 6 13/11/30
T-588 USER MANUAL
1. INTRODUCTION
1.1 Front panel
POWER button
(1)
(2) POWER indicator light (red light)
(3) MUTE button
(4) MUTE indicator light (red light)
(5) MIC input jack (φ3.5mm)
(6) Input gain control
(7) Headphones output gain control
(8) UP button
(9) MENU button
1.2 LCD screen
(10) DOWN button
(11) Headphones output jack (φ3.5mm)
(12) Interior and external monitor switch
(13) Interior monitor indicator (red light)
(14) External monitor indicator (green light)
(15) LCD screen
(16) Input signal strength indicator: red light
(17) Input signal strength indicator: green light
(18) Input signal strength indicator: yellow light
Showing working channel (CH.01) or operating country mode
RF signal strength indicator.
--- N/A
2 of 6 13/11/30
Appears when keypad is locked
Mono operating indicator
--- N/A
--- N/A
Stereo operating indicator
Appears when Test Tone function is on
--- N/A
--- N/A
--- N/A
--- N/A
1.3 Rear pane NEW REAR PANEL PROPOSED SILKSCREEN
MONITOR
IN
STEREO
AUX IN
R
W
P
H
P
C
M
I
E
N
L
I
I
C
M
R
L
ANTENNA
REC OUT
GAIN
MIC/LINE IN
POWER
IUPUT
15V DC
Specifications:
Dimensions(W*H*D):140mm*45 mm*116 mm;
Weight: 1450g;
2.FUNCTION DESCRIPTION
2.1 POWER ON/OFF
Pressing and holding [POWER] button for 0.5 seconds to turn on the radio, the LCD will indicate the
default band [USA] or [CAN] one second, then go to the default operating frequency [88.1MHZ] (see Fig 1)
or last operating frequency, pressing it for 0.5 seconds again will turn off the radio.
Note: When the transmitter is turned on, the display will show full display during the start up.
3 of 6 13/11/30
Fig 1
2.2 Frequency SETTING: The device built-in the USA & CAN operating frequency & power
level (see frequency list in Fig. 8), press the [UP] or [DOWN] button to choose the preset
operating frequency.
2.3 Choose the USA or CAN Band
(a) Hold press the [Monitor] & [Power] button 3 second to turn on the radio, the LCD
indicate the previous operating band (USA or CAN) flashing,
(b) Press the [MENU] button to the band select mode, the LCD stop flashing
(c) Press the [UP] or [DOWN] button to choose the USA or CAN band (the power level has
preset in radio by program software)
(d) Press the [MENU] button to store the setting & go to the default operating frequency for
a while.
2.4 Frequency Lock:
Pressing and holding the [UP] or [DOWN] button for 5 seconds, the display will show “
“ icon (see Fig 2), the transmitter will be locked out the operating frequency, it will go back to
unlocked by pressing and holding the [UP] or [DOWN] button for 5 seconds again. The lock option
will remain even if the unit is turned off and on again or is unplugged from the power source.
Pressed and held the [MENU] button for 6 seconds, then the transmitter will enter into program
mode, there are “Stereo/Mono”, Test Tone, Exit, three function in setting menu.
After 10 seconds of inactivity the transmitter automatically will exit the program mode.
Fig 2
3. Menu Options:
3.1 Stereo/ Mono
Enter into program mode second option will blink “Stereo”,
Press the [UP] or [DOWN] button to select the [Mono] or [Stereo].
•Press [MENU] button to save the selected value and to go to the next menu option.
4 of 6 13/11/30
The LCD display of Stereo & Mono see Fig 3 & Fig 4.
Fig.3 Fig. 4
3.2 Test Tone No test tone please remove this option
Enter into program mode forth option will blink “TONE”.
Fig 5 Fig 6
•Press the [UP] or [DOWN] button to select the [TONE.OFF] or [TONE. ON](see Fig 5 & 6).
•Press [MENU] button to save the selected value and to go to the next menu option.
Fig 7
Enter into program mode fifth option will blink [EXIT]
•Press [MENU] button to exit the menu option.
Press and hold down [UP] + [DOWN] buttons, then Power On the transmitter, it will go back to the
initial program channel, the default frequency is [88.1MHZ].
NOTE! This function is very useful if the transmitter is malfunctioning or if you want cancel all made
settings. Reset shall restore the transmitter to default settings.
3.3 Exit
4. RESET
5 of 6 13/11/30
Telescopic antenna length adjustment.
In a manner to achieve good performances (more coverage distance) with your FM
transmitter, it is mandatory to adjust the length of the telescopic antenna to it’s
associated frequency.
Procedures: 1) Choose a free frequency (see Frequency selection page 5). 2) Take note of
the associated length (ex: 88.5MHz = 35 inches). 3) With the help of a
measuring tape or ruler; extend the telescopic
antenna in a manner to obtain the desired length (from base to tip of
antenna).
Frequency
Rod
Frequency
Rod
Frequency
Rod
Frequency
Rod
MHz
MHz
length
Inches
35
35
35
35
35
35
35
35
35
35
35
35
35
35
34
34
33
33
33
34 1/2
34 1/2
33 1/2
32 1/2
32 1/2
32
32
93.3
93.5
93.7
93.9
94.1
94.3
94.5
94.7
94.9
95.1
95.3
95.5
95.7
95.9
96.1
96.3
96.5
96.7
96.9
97.1
97.3
97.5
97.7
97.9
98.1
98.3
88.1
88.3
88.5
88.7
88.9
89.1
89.3
89.5
89.7
89.9
90.1
90.3
90.5
90.7
90.9
91.1
91.3
91.5
91.7
91.9
92.1
92.3
92.5
92.7
92.9
93.1
length
Inches
32
32
32
32
31 1/2
31 1/2
31 1/2
31 1/2
30 1/2
30 1/2
30 1/2
30 1/2
30 1/2
31
31
31
31
31
31
30
30
30
30
30
30
30
MHz
98.5
98.7
98.9
99.1
99.3
99.5
99.7
99.9
100.1
100.3
100.5
100.7
100.9
101.1
101.3
101.5
101.7
101.9
102.1
102.3
102.5
102.7
102.9
103.1
103.3
103.5
Fig. 8
length
Inches
29 1/2
29 1/2
29 1/2
29 1/2
29 1/2
28 1/2
28 1/2
28 1/2
28 1/2
28 1/2
29
29
29
29
29
29
28
28
28
28
28
28
28
28
27 1/2
27 1/2
MHz
103.7
103.9
104.1
104.3
104.5
104.7
104.9
105.1
105.3
105.5
105.7
105.9
106.1
106.3
106.5
106.7
106.9
107.1
107.3
107.5
107.7
107.9
length
Inches
27 1/2
27 1/2
27 1/2
27 1/2
26 1/2
26 1/2
26 1/2
26 1/2
26 1/2
26 1/2
27
27
27
27
27
27
27
27
26
26
26
26
6 of 6 13/11/30
FCC Caution:
Any Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
IMPORTANT NOTE:
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment.This equipment should be installed and operated with minimum distance 40cm
between the radiator& your body.
Innovation, Science, and Economic Development Canada
ISEDC Warning
This device complies with
licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR d' Innovation, Sciences et Développement économique
Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes :
(1) l'appareil nedoit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d'en compromettre le fonctionnement.
The device is compliance with RF exposure guidelines, users can obtain Canadian information on
RF exposure and compliance.The minimum distance from body to use the device is 51cm.
Le présent appareil est conforme Après examen de ce matériel aux conformité ou aux limites
d’intensité de champ RF, les utilisateurs peuvent sur l’exposition aux radiofréquences et la
conformité and compliance d’acquérir les informations correspondantes. La distance minimale du
corps à utiliser le dispositif est de 51cm.