= Contin technology Door Alarm System:
Date: 9/4/2018 1. Structure Electric Lock 220VAC
= py) Door Release Door Lock ki
. = seat er TL-2020P
, XN a Power Core RF Reset Button SS ee Signal Cable TL-4014W RF 125kHz Wristband Transmitter eo TL-4012 (( RFAS3 System Block Diagram Devices:
1. Main Device Single Door Strip Monitor(Code: TL-4005) 2. Resident Wristband Transmitter(Code: TL-4012) 3. Wireless Reset Button(Code: TL-4014W) 4. Pager TL-4012 5. Central Monitor Unit TL-4015 Optional Devices:
1. Power Supply, 12V DC, 1A 2. Magnetic Door Sensor 3. Electric Lock 4. Siren 5. Emergency Door Release(Glass Break button) 6. Door Lock Indicator Flat G, 1/F, Valiant industrial Centre, 2-12 Au Pui Wan Street, Fo Tan, Sha Tin, HK T:(852) 2398 2562 F:(852) 2398 1536 www.contintechind.com
Flat G, 1/F, Valiant Industrial Centre, 5 2-12 Au Pui Wan Street, Fo Tan, Sha Tin, HK T:(852) 2398 2562 F:(852) 2398 1536 2 www.contintechind.com [J Operation:
When door open(with magnetic door sensor) a. Count when door is detected as open(could be set as Sseconds~75seconds), TL-4005 alarm b. Can be reset by TL-4014W or tamper proof reset option c. After reset, TL-4005 will pause function d. Once door closed, TL-4005 will restart When TL-4012 get close to TL-4005(with magnetic door sensor) a. TL-4005 will awake TL-4012 by sending low frequency signal, which cover 1-8m area
*Please do not put TL-4012 too close to the TL-4005 for testing b. TL-4012 send out its ID to TL-4005 c. TL-4005 will try to lock the door and react in 3 ways:
i. if it failed to lock the door, it will alarm immediately ii. if the door is successfully be locked, and TL-4012 is detected leave the range, the door will automatically unlock after 3 seconds iii. if the door is successfully be locked, and TL-4012 is detected stay in the range, after 3 seconds, TL-4005 will alarm d. The alarm could be reset by using TL-4014W, TL-4005 will enter reset delay period for Osec~75sec. When TL-4012 get close to TL-4005(without magnetic door sensor) a. TL-4005 will awake TL-4012 by sending low frequency signal, which cover 1-8m area b. TL-4012 send out its ID to TL-4005 c. If TL-4012 is being detected and have not leave within 3seconds, TL-4005 will alarm d. The alarm could be reset by using TL-4014W, TL-4005 will pause function for 3mins Temporarily pause TL-4005 a. Press and hold TL-4014W for Sseconds, system will pause for 1 mins b. Press TL-4014W once again, system will return to normal Flat G, 1/F, Valiant Industrial Centre,
= . 2-12 Au Pui Wan Street, Fo Tan, Sha Tin, HK lL S fF NH KR T:(852) 2398 2562 Contin technology F:(852) 2398 1538 www.contintechind.com 2. Introduction of Devices 2.1. TL-4005 Outlook Wire Connection Area Back 2.2 Specification Power Output: 12V DC, 1A Max Current: 300ma Relay Contact Rating: (Include Electric Lock/Siren/Door Lock Indicator) Switching voltage 12VDC/24VDC, Switching current 500ma Max Size: 360mm(L) x 68mm(W) x 32mm(D) Flat G, 1/F, Valiant Industrial Centre, 2-12 Au Pui Wan Street, Fo Tan, Sha Tin, HK S F HR RK T-(852) 2398 2562 Contin technology F:(852) 2398 1536 www.contintechind.com 2.3 Connection Lock Indicat Door Lock Indicator te Electric Lock Power In Power In GND. GND 12VDC Input B- Siren Power In Max 1A GND. GND ya a>
Q th Terminal Description 1 | Ground Power input GND 2 | 12VDC Power input 12V DC i - __|
3 | LED+ Door Lock Indicator, door lock status shown when short circuit 4 | LED- Door Lock Indicator 5 | Lock+ Electric lock power out, door locked when short circuit 6 | Lock- Electric lock power out Alarm + Alarm output +, alarm when short circuit 8 | Alarm - Alarm output -
J2 Terminal Description a | Reset + Connect to fire alarm switch 2 | Reset - Connect to fire alarm switch 3 | Magnet + Magnetic door signal in 4 | Magnet - Magnetic door signal in Flat G, 1/F, Valiant Industrial Centre,
=| 2-12 Au Pui Wan Street, Fo Tan, Sha Tin, HK S fF FH KR
| Contin technology Pleo tes 2 www.contintechind.com 2.4 System Setup sw1 Power Switch NO 42V_LED+ _LED- Locke Lock: Alarms Alarm eeeeeeoers:
2
SW5 DATX Distance Range sw3 DATX Sensitivity Level Select Program Button SW4 Buzzer Volume
$1 Number Input 1. SW1 Power Switch 2. SW3 & SW5 Setup the sensing range SW3 adjust the distance, long distance = within 8m; short distance = within 4m SWS5 fine tuning the distance, 1 is shortest, 4 is longest 3. SW4 adjust the volume 4. Other parameter setting:
a. S1 choose setting(refer to the table listed in below) b. Press(Program), Bi sounds and enter setting mode, Green LED(Door Open) & Red LED(Alarm) on c. $1 enter parameter d. Press program button, parameter entered Lig #
BH Contin technology Parameter List (Apart from 1-9, A=10, B=11, C=12, D=13,E=14,F=15) Flat G, 1/F, Valiant Industrial Centre, 2-12 Au Pui Wan Street, Fo Tan, Sha Tin, HK 7:(852) 2398 2562 F:(852) 2398 1536 www.contintechind.com () Setting Setting Code Description Parameter(N) ami Zone No. (01-99) 0(For digit in tens) 1(For digit in ones) Zone no. has to be same as the TL-4015s for communication 0-9 0-9 Door No. 2 Door ID for showing in the TL-4015 0-15 Door Lock Time Out After the time will release the door and alarm 5sec.~75sec(5s x N) 1-15 No time limit for the lock door Reset Delay After using reset button or reset key to cancel the alarm, the system will be pause for a preset period, no alarm will be triggered during the period Time is Osec.~75sec(5s x N) 0-15 Door Open Alarm Delay Turn off the door detection When door magnetic detector check the door is open, alarm will be triggered after the delay time Time is 5sec.~75sec(5s x N) 0 1-15 Alarm Relay Output Keep Short for alarming Impulse output(400ms On/400ms Off) Resume original setting Zone no. :87 Door no. :01 Door Lock Time Out: 07 (35sec) Reset delay: 0 sec Door open alarm delay: Turn off Alarm relay: normal close alarm Flat G, 1/F, Valiant Industrial Centre, 2-12 Au Pui Wan Street, Fo Tan, Sha Tin, HK S FF BH RK
. T(8 8 256 Contin technology reel sae 1538 9 www.contintechind.com [J 2.5 Signal Door Power Signal System Pause and Alarm Reset Door Lock Items Description 1 Door Door close will light up Green LED Open/Close Door open will flash Green LED It will not light when door magnetic detection function is closed
[2 Alarm | Red LED flash when alarm(TL-4012 get close to the device or door open) 3 Reset/Pause Yellow LED flash indicates that the system is on reset delay or pause, system is temporarily not working 4 Door Lock Green LED light up indicates the door is locking 5 Program Mode | Door Open/Close LED and Alarm LED light up Flat G, 1/F, Valiant Industrial Centre,
-L 6 A # 2-12 Au Pui Wan Street, Fo Tan, Sha Tin, HK @
. T:(852) 2398 2562
=") Contin technology pice) 2398 1536 2 www.contintechind.com [J 3. TL-4012 3.1 Introduction of Transmitter(TL-4012) P 4 EED Indiestor Resident Wristband Transmitter will be waked by TL-4005 and start to C f send signal to TL-4005. B 3.2 Specification Batter: CR2450 Frequency: 2.4Ghz 3.3 Instruction LED will flash when it get closed to TL-4005 3.4 Check On / Off Status Place magnetic on right side Status LED On Flashing Off Keep light up 3.5 TurnOn Put the magnetic field on the right for 5 seconds, LED Off and turns on the power. 3.6 Turn Off Step 1: Put the magnetic field on the right side for 5 seconds, LED stops flashing and keep light up;
Step 2: Remove the magnetic until LED light off;
Step 3: Put the magnetic field on the right side again until LED light up;
Step 4: Remove the magnetic and TL-4012 will turn off the power. Flat G, 1/F, Valiant Industrial Centre,
= |= a a a 2-12 Au Pui Wan Street, Fo Tan, Sha Tin, HK
. T:(852) 2398 2562 a | Contin technology Ls 2308 1536 www.contintechind.com [J 4. TL-4014W 4.1 Introduction of Reset Button(TL-4014W) TL-4014W will reset the alarm of TL-4005. If the button is press during door open status(with door detector), it can pause the TL-4005 until the door is closed. If the button is pressed for 3 seconds while door detection is not applied, TL-4005 will pause for 3 mins. Low battery signal will be sent to TL-4005. 4.2 Specification Battery: CR2450 Frequency: 2.4Ghz 5. Message Displayed on WC-TL-4015 5.1 Single Door Strip Monitor Setting Procedure a)Turn on the TL-4015 b)Press and hold Prog. Button for 2 seconds, TL-4015 will enter program mode, PROG will light on the left hand corner c)Press Prog. Button one more time, TL-4015 will enter Single Door Strip Monitor setting mode, Single Door Strip Monitor icon will be shown PROG Tt f Ltt d)Press up/down button enter the door no., it has to be the same as the number entered in TL-4005 e)Press Quit to finish the setting Flat G, 1/F, Valiant Industrial Centre, 2-12 Au Pui Wan Street, Fo Tan, Sha Tin, HK 7:(852) 2398 2562 F:(852) 2398 1536 www.contintechind.com [
5.2 Message shown 1. TL-4012 alarm D=Door Door No. DATXs ID no. DATXs Icon
*Door no. from 10-15, will be shown as 0, b, c, E and F 2. TL-4012 in low battery ALARM -
3. Reset button in low batter 4 Icon for Reset Button Flat G, 1/F, Valiant Industrial Centre, 5 2-12 Au Pui Wan Street, Fo Tan, Sha Tin, HK L. # # SH T-(852) 2398 2562 Contin technology F:(852) 2398 1536 www.contintechind.com [2 4. Door not close alarm Icon for door not close
r
a
Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. tIncrease the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
~end~