all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Users Manual | Users Manual | 3.91 MiB | ||||
1 | Cover Letter(s) | |||||||
1 | External Photos | |||||||
1 | Attestation Statements | |||||||
1 | Internal Photos | |||||||
1 | ID Label/Location Info | |||||||
1 | Cover Letter(s) | |||||||
1 | Test Report | |||||||
1 | Test Setup Photos |
1 | Users Manual | Users Manual | 3.91 MiB |
RFAL-DIMR-EN (REV. B) ENGLISH IN U.S.A.: Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269 866-853-4293 RF SMART DIMMER RF9540-N For dimmable LED/ CFL/ incandecent/ MLV/ ELV/ Halogen/ dimmable Fluorescent RF9536-N For incandescent/MLV RF9537-N for ELV Lighting Fixtures / RF9542-Z RF Accessory for multi-location Z-Wave Device Network Installation Instructions 1. This product may be added to a new or existing Z-Wave network. A Cooper Wiring Devices Z-Wave device has a blue LED, which will blink when the device is not included in a Z-Wave network. The LED stops blinking when the device is in a network. INSTALLATION INSTRUCTIONS WARNING:
Turn OFF circuit breaker or remove fuse(s) and test that power is off before wiring. Never wire any electrical device with power turned on. Wiring dimmer with power on may cause permanent damage to dimmer and void warranty. If you are not sure about any part of these instructions, please contact a for inclusion (Install, Add Device, Add Node, Include Device, etc.). Then press the device switch one time to include it in the network. The LED will stop blinking. 2. To include this device in a Z-Wave network, select the command on your Z Wave controller licensed electrician. 3.To exclude this device from a Z-Wave network, select the command on your Z-Wave controller for exclusion (Uninstall, Remove Device, Remove Node, Exclude Device, etc.). Then press the device switch one time to exclude it from the network. The LED will start blinking. 4. This product works with other Z-Wave products from different vendors and product categories as part of the same network. 5. This product is a listening node and it will act as a repeater in the Z-Wave network. It will perform the repeater function with Z-Wave products from Cooper and from other Z-Wave vendors. IMPORTANT:
RF Smart dimmer will not work or will become damaged if wired incorrectly, and warranty will be voided. Refer to wiring instructions provided on reverse side. OPERATION INSTRUCTIONS Press once to turn lights ON at previously selected level. Press again to turn lights OFF. When lights are OFF, press and hold for 2 seconds for full brightness. When lights are ON, press and hold for 2 seconds until the blue LED blinks. After the preset delay, the lights will begin fading to OFF (up to 4 minutes). Amber ON/OFF LED indicates that dimmer is turned on. DIMMING LEVEL ADJUSTMENT (RF9540-N only) For maximum compatibility with different loads types, RF9540-N allows the user to set the minimum level. Also to save on power consumption RF9540-N allows the user to set the maximum level. 1. After installing the dimmer and restoring power, press on/off button to turn on the light. 2. Press and hold on/off button for five seconds until the blue dimmer LEDs begin to cycle rapidly (NOTICE- after two seconds blue dimmer LEDs will start to flash indicating activation of the delay off feature. Continue holding the ON/OFF button for three additional seconds until the blue dimmer LEDs begin to cycle rapidly.) 3. Release the button. Dimmer will set the light to the previously saved minimum level (that may cause the light to flicker or turn off). During initial setup, the light will set to the factory minimum default. 4. Press either the dim or bright buttons to change the minimum level until the light output is acceptable. 5. Press ON/OFF button. Blue dimmer LEDs will start to cycle rapidly again and the dimmer light will go to previously saved maximum level. 6. Press either the dim or bright buttons to change the maximum level until the light output is acceptable. 7. Press ON/OFF button, LED will flash indicating completion of programming NOTE To restore the default min/max, repeat the steps above and adjust light levels to full min/max settings by pressing dim/bright buttons until the light output no longer changes. NOTE - User could ignore setting max or min by pressing on/off button without changing the dimmer level. Rapid start feature (RF9540-N only) This feature ensures that LED/CFL lights turn on when the dimmer preset level is low. With this setting enabled, the lights may momentarily be brighter than the preset level (less than one sec-
ond) and then dim down to the preset level. Depending on the type of light used, this feature may not be needed. To enable/disable the feature, turn lights on. Press and hold the on/off button for 10 seconds until the blue dimmer LEDs flash for the third time, then release the button. CAUTION:
1. Use only with 120V AC 60 Hz. 2. Do not exceed maximum rating of the dimmer as indicated on the device. 3. Must be installed and used in accordance with electrical codes. 4. If a bare copper or green ground connection is not available in the wallbox, contact a licensed electrician for installation. 5. Use only #14 or #12 copper wire rated for at least 75C with these devices. Do not use with Aluminum wire. NOTES:
1. The RF Master Dimmer is wired directly to the light fixture. 2. The RF Smart Dimmer is not compatible with standard 3-way switches. 3. For Multi-location applications (3-Way or 4-Way) the RF Smart Accessory Dimmer(s) is used along with one RF Master Dimmer. 4. The RF Accessory Dimmer communicates via RF signals to control the light from more than one location. 5. For multi-location control use RF Smart Dimmer Master direct wired to the light along with RF Accessory (RF9542-Z). The RF Accessory does not require direct connection to the light (use Association function). 6. When installing more than one dimmer in a wall box the total lamp wattage may need to be reduced. See Ganging chart. GANGING When ganging multiple Smart Dimmer Masters in one wall box, derating is required as follows Catalog #
RF9536-N RF9537-N Double Gang 800W/VA 800W 600W/VA Tripple Gang 800W/VA 800W 600W/VA Single Gang 1000W/VA 1000W 600W/VA RF9540-N Loads INC/MLV ELV INC/ ELV/ FLR/
Halogen/ MLV CFL/ LED 300W 300W 300W READ BEFORE INSTALLATION!
Switch Identification White White ACCESSORY ACCESSORY Green d e R ACCESSORY Green Disconnect Switch Black Master Control Black Accessory Troubleshooting Guide Symptom Possible Cause No Function. All LEDs are OFF Erratic operation or flickering LEDs Lights turns on after long delay Functions normally using the dimmer push buttons but not from Z-Wave controller and one of the blue LEDs blinks ON and OFF about once per second Functions normally using the Master dimmer control but not from Z-Wave controller and no LEDs are blinking Functions normally both locally and from a Z-Wave controller but cant be controlled from a dimmer accessory switch (RF9542-Z) or other Z-Wave device Dimmer is warm to touch after a period of time A) Light bulb(s) burned out B) Circuit breaker is off or tripped C) Disconnect switch on the dimmer is pulled out to the OFF position D) Improper wiring E) Defective dimmer A) Loose wiring connections B) Low dim setting
(RF9540-N) A) Rapid start feature is disabled (RF9540-N) B) Low dim setting
(RF9540-N) Dimmer is not included in Z-Wave network Solution A) Replace light bulb B) Turn on the circuit breaker C) Push in the disconnect switch on the dimmer D) Check and correct wiring E) Replace dimmer A) Check and correct wiring B) Set minimum brightness to a higher level (RF9540-N) A) Enable rapid start feature
(RF9540-N) B) Set minimum brightness to a higher level (RF9540-N) Include dimmer in a Z-Wave network using a Z-Wave controller. Refer to Z-Wave controller user manual for details Problem with RF communica-
tion on dimmer Replace dimmer The dimmer accessory or other Z-Wave device is not associated with the dimmer you wish to control This is normal Create an association between the dimmer acces-
sory or other device and the dimmer. Refer to your Z-Wave controller user manual for details No action required 1.1 1.3 Bare Single Location Control Installation (requires one Master dimmer) 1.5 1.3 1.41.2 Black
- Hot Tag
-
Black To Light White White Master Black Green Tag Black Red Black White Identify existing wiring (This switch will be a single-pole) and tag Hot wire. Use voltage tester as necessary to confirm Hot wire (Voltage will be present at the Hot wire when the lights are off). 1.4 1.6 TOP Disconnect existing switch and remove. Connect master dimmer as shown by connecting black wire of dimmer to tagged Hot wire. Red wire must be connected to the wire that goes to the light. Hot 120V Black Red Gently push dimmer into place and secure with mounting screws. Make sure disconnect switch at bottom of master is fully pushed in Green Neutral Ground White Light Fixture R E T S A M R E M M D I White 2.1 2.1 Black Red Bare Tag Black Two Location Control Installation (requires one Master and one Accessory) 2.2 2.2 Black White Red Bare Black Tag 2.4 2.3 Accessory LOCATION A Black Red Black Tag ACCESSORY ACCESSORY Green White White Identify existing wiring (both existing switches will be 3-way) Tag common wire on both 3-Way switches (see How to Identify Common Wires section*) 2.4 2.5 Master R E T S A M R E M M D I Red Green Black Tag Red White Black Black Disconnect existing switch and remove. Connect Accessory Dimmer in Location A as shown. White NOTE: The Circuit Breaker must be turned ON during this step and the switches must be set so that the light is OFF. Ensure that all wires are safely separated before turning the Circuit Breaker ON. Connect the tester between the tagged common terminal and ground in one of the boxes to determine the location for the Accessory Dimmer. If the test indicates voltage then that will be Location A, and will be used for the Accessory Dimmer. If voltage is not present then the other 3-way location will be Location A. NOTE: Disconnect power after this step. Hot 120V Neutral Ground White Y R O S S E C C A R E M M D I Green Black Traveler Wires Red Black White Black Green Ground White LOCATION A R E T S A M R E M M D I Red White Light Fixture Three Location Control Installation (requires one Master and two Accessory dimmers) Red Tag Black Red Bare Black Tag 3.2 3.2 Accessory 4-Way Location Tag Red Black White White Green Black ACCESSORY Identify existing wiring (4-way switches) Tag common wire on 4-Way switch. (see How to Identify Common Wires section*) Red Hot 120V Neutral Ground White Y R O S S E C C A R E M M D I Green Red Traveler Wires Black White Green Ground Y R O S S E C C A R E M M D I Black Traveler Wires Black White White LOCATION A White White White Ground White Black Green R E T S A M R E M M D I Red Light Fixture Connect the second Accessory Dimmer (4-way switch) as shown. IMPORTANT! How to identify Common Wires*
Two location:
Each switch will have insulated wires connected to three terminal screws plus a green or bare wire connected to a green terminal screw. The three terminals are usually one dark colored screw and two light colored screws (ignore the Green screw). Alternatively, the three screws may be the same color and one will be marked COMMON or COM Find the wires connected to the dark or COMMON screws. Usually these wires are black but may be red or blue. Tag these wires on both switches to identify when wiring. Three location:
Two of the existing switches will be 3-way. The 3-way switches will be located at each end of the circuit with a 4-way switch in between. TAG the two 3-way switches as in the Two Location Control section. The 4-Way switch has 4 insu-
lated wires connected to 4 terminal screws. VERY IMPORTANT - TAG two same color insulated wires, which are connected to screws of opposite colors. Refer to 1.4 to push dimmers into place. White 3.1 3.1 COOPER WIRING DEVICES LIMITED 2 YEAR WARRANTY Cooper Wiring Devices (CWD) warrants its RF Smart Dimmer System to be free of defects in materials and workmanship in normal use and service for a period of two years from date of original purchase. THIS TWO (2) YEAR LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS, OR LIABILITIES, EXPRESSED OR IMPLIED (INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS IN DURATION IN EXCESS OF TWO YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE). NO AGENT, REPRESENTATIVE, OR EMPLOYEE OF CWD HAS AUTHORITY TO INCREASE OR ALTER THE OBLIGATIONS OF CWD UNDER THIS WARRANTY. To obtain warranty service for any properly installed CWD RF Smart Dimmer System that proves defective in normal use send the defective RF Smart Dimmer System prepaid and insured to Quality Control Dept., Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269; in Canada: Cooper Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8. CWD will repair or replace the defective unit, at its option. CWD will not be responsible under this warranty if examination shows that the defective condition of the unit was caused by misuse, abuse, improper installation, alteration, improper maintenance or repair of damage in shipment to CWD. CWD SHALL HAVE NO RESPONSIBILITY FOR INSTALLATION OF THE RF SMART DIMMER SYSTEM, OR FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR ANY SPECIAL, INCIDENTAL, CONTINGENT, OR CONSEQUEN-
TIAL DAMAGES OF ANY KIND, RESULTING FROM DEFECTS IN THE RF SMART DIMMER SYSTEM OR FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT. THE EXCLUSIVE REMEDY FOR BREACH OF THE LIMITED WARRANTY CONTAINED HEREIN IS THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT AT CWDS OPTION. IMPLIED WARRANTIES (IF ANY) INCLUDING, BUT NOT LIMITED TO IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABIITY, ARE LIMITED IN DURATION TO A PERIOD ENDING TWO YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE. IN NO CASE SHALL CWDS LIABILITY UNDER ANY OTHER REMEDY PRESCRIBED BY LAW EXCEED THE PURCHASE PRICE. Some states do not allow the exclusion or limitation of incidental or consequential dam-
ages or allow disclaimers or modifications of or limitations on how long an implied warranty lasts, so the above limitations may not apply to you. Some Canadian provinces do not allow exclusion or variance of implied warranties so that some or all of the above limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state and province to province. Read enclosed instructions carefully. If you have any questions concerning use or care of this product, please write: Consumer Service Division, Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269. RFAL-DIMR-FR (REV. B) FRANAIS IN U.S.A.: Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269 866-853-4293 GRADATEUR INTELLIGENT TLCOMMANDE RF9540-N Pour ampoules DEL, fluocompactes, incandescentes, BTM, EBT, halognes et fluorescents intensit variable RF9536-N Pour luminaires ampoules incandescentes et BTM RF9537-N Pour luminaires EBT/ RF9542-Z Accessoire RF pour emplacements multiples. INSTRUCTIONS DINSTALLATION AVERTISSEMENT :
Dclencher le disjoncteur ou retirer les fusibles et sassurer que lalimentation est hors tension avant le cblage. Ne jamais cbler aucun dispositif lectrique lorsque lalimentation est sous tension. Le cblage du gradateur alors que lalimentation est sous tension peut causer des dommages irrversibles au gradateur et annuler la garantie. Communiquer avec un lectricien qualifi en cas de tout doute concernant les Instructions dinstallation du dispositif de rseau Z-Wave 1. Ce produit peut tre ajout un nouveau rseau ou un rseau existant Z-Wave. Un dispositif Z-Wave de Cooper Wiring comporte une DEL bleue qui clignotera lorsque le dispositif nest pas inclus au rseau Z-Wave. La DEL cesse de clignoter lorsque le dispositif est intgr au rseau. 2. Pour incorporer ce dispositif au rseau Z-Wave, slectionner la commande dincorporation du contrleur Z-Wave (Installation, ajout de dispositif, ajout dun noeud, incorporation dun dispositif, etc.)Appuyer une fois sur linterrupteur du dispositif pour lincorporer au rseau. Le clignotement de la DEL cessera. instructions. IMPORTANT :
Le gradateur intelligent RF ne fonctionnera pas ou sendommagera si le cblage est incorrect et ceci annulera la garantie. Consulter les instructions de cblage fournies au dos. MODE DEMPLOI Appuyer une fois pour allumer les ampoules selon le niveau slectionn auparavant. Appuyer nouveau pour teindre les ampoules. Lorsque les ampoules sont TEINTES, appuyer et maintenir le bouton enfonc pendant 2 secondes pour obtenir lintensit de luminosit maximale. Lorsque les ampoules sont ALLUMES, appuyer et maintenir le bouton enfonc pendant 2 secondes jusqu ce que les tmoins DEL bleue clignotent. Aprs la dure prrgle, lintensit lumineuse des ampoules commencera diminuer pour finalement steindre (jusqu 4 minutes). Le tmoin de marche/arrt DEL ambre indique que le gradateur est sous tension. RGLAGE DE LINTENSIT LUMINEUSE (RF9540-N seulement) Pour une compatibilit maximale avec les diffrents types de charges, le modle RF9540-N permet le rglage du niveau minimum par lutilisateur. En plus dconomiser lnergie, le modle RF9540-N permet le rglage du niveau maximum par lutilisateur. 1. Aprs linstallation du gradateur et la mise sous tension de lalimentation lectrique, appuyer sur linterrupteur de marche/arrt (ON/OFF) pour allumer les ampoules. 2. Appuyer et maintenir linterrupteur de marche/arrt (ON/OFF) pendant 5 secondes, jusqu ce que les tmoins DEL bleue commencent manoeuvrer rapidement (AVIS Les tmoins DEL bleue commenceront clignoter aprs 2 secondes pour indiquer lactivation de la caractristique de mise hors tension du dlai. Maintenir linterrupteur de marche/arrt
[ON/OFF] pendant 3 secondes de plus, jusqu ce que le tmoin DEL bleue du gradateur commence manoeuvrer rapidement.) 3. Relcher le bouton. Le gradateur rglera la luminosit selon le niveau minimum prcdent
(ce qui peut faire scintiller ou teindre lampoule). Pendant le premier rglage, lampoule se rglera selon le minimum par dfaut tabli en usine. 4. Appuyer sur le gradateur ou les boutons dintensit lumineuse pour modifier le niveau minimum jusqu ce que le flux lumineux soit acceptable. 5. Appuyer sur linterrupteur de marche/arrt (ON/OFF). Les DEL bleues du gradateur commenceront manoeuvrer rapidement nouveau et lintensit lumineuse du gradateur retournera au niveau maximum sauvegard auparavant. 6. Appuyer sur le gradateur ou les boutons dintensit lumineuse pour modifier le niveau maximum jusqu ce que le flux lumineux soit acceptable. 7. Appuyer sur linterrupteur de marche/arrt (ON/OFF); le tmoin DEL clignote pour indiquer que la programmation est russie. REMARQUE Pour rtablir le niveau min/max par dfaut, rpter les tapes ci-dessus pour rgler les niveaux dintensit lumineuse aux rglages min/max optimaux en appuyant sur les boutons dintensit lumineuse ou du gradateur jusqu ce que le flux lumineux devienne stable. REMARQUE Lutilisateur peut ignorer le rglage max. ou min. en appuyant sur linterrupteur de marche/arrt (ON/OFF) sans modifier le niveau dintensit lumineuse du gradateur. 3. Pour exclure un dispositif dun rseau Z-Wave, slectionner la commande dexclusion du contrleur Z-Wave (Dsinstaller, retrait du dispositif, retrait du noeud, exclure le dispositif, etc.). Appuyer une fois sur linterrupteur du dispositif pour lexclure du rseau. La DEL commencera clignoter. 4. Ce produit fonctionne avec les autres produits Z-Wave dautres marques et catgories de produit comme partie intgrante dun mme rseau. 5. Ce produit est un noeud dcoute et ragira comme tant un rpteur du rseau Z-Wave. Il reproduira la fonction de rpteur avec les produits Z-Wave de Cooper et dautres fabricants. Interrupteur de marche/
arrt (ON/OFF) Tmoins dintensit lumineuse (bleus) Tmoin de marche/arrt
(ON/OFF) DEL (ambr) Appuyer pour augmenter lintensit Le niveau dintensit lumineuse peut tre rgl lorsque les ampoules sont teintes ou allumes. Appuyer sur DIM (gradateur) Dbrancher linterrupteur Tirer pour changer les ampoules (gradateur gnral seulement) LIRE AVANT LINSTALLATION!
Identification de linterrupteur Blanc Blanc ACCESSOIRE ACCESSOIRE Dbrancher linterrupteur Vert Noir e g u o R ACCESSOIRE Vert Commande centrale Noir Accessoire Caractristique dallumage rapide (RF9540-N seulement) Cette caractristique assure lallumage des ampoules DEL et fluocompactes lorsque le niveau prrgl du gradateur est faible. Alors que le rglage est activ, les ampoules seront momentanment plus brillantes que le niveau prrgl (moins dune seconde) puis lintensit diminuera jusquau niveau prrgl. Selon de type dampoule utilise, cette caractristique peut savrer inutile. Allumer les ampoules pour activer ou dsactiver la caractristique. Appuyer et maintenir linterrupteur de marche/arrt (ON/OFF) enfonc pendant 10 secondes, jusqu ce que les tmoins DEL bleue du gradateur clignotent pour la troisime fois puis relcher le bouton. Dpannage Problme Aucune fonction. Tous les tmoins DEL sont teints MISE EN GARDE :
1. utiliser uniquement avec 120 VCA, 60 Hz. 2. Ne pas dpasser la caractristique nominale maximale indique sur le gradateur. 3. Linstallation et lutilisation doivent tre conformes aux codes de llectricit. 4. Si une connexion nue dun fil en cuivre ou de mise la terre nest pas disponible dans le coffret mural, communiquer avec un lectricien qualifi pour faire linstallation. 5. Utiliser uniquement des fils de gabarit no 14 ou 12 ayant une caractristique nominale dau moins 75 C avec ces dispositifs. Ne pas utiliser de fil en aluminium. REMARQUES :
1. Le gradateur gnral RF est cbl directement au luminaire. 2. Le gradateur gnral RF nest pas compatible avec les interrupteurs 3 voies. 3. Pour des applications endroits multiples (3 ou 4 voies), le gradateur accessoire intelligent RF est utilis conjointement avec un gradateur gnral RF. 4. Le gradateur accessoire RF communique laide de radiofrquences pour commander les luminaires situs plus dun endroit. 5. Pour la commande dendroits multiples, utiliser le gradateur intelligent gnral RF cblage direct pour allumer les accessoires laide de la radiofrquence (RF9542-Z). Laccessoire RF nexige pas de connexion directe au luminaire (utiliser la fonction dassociation). 6. Lors de linstallation de plusieurs gradateurs la boite murale, le total de la puissance des ampoules doit tre diminu. Voir le tableau de groupage. GROUPAGE Lorsque lon regroupe plusieurs gradateurs intelligents gnraux dans un seul coffret mural, le dclassement requis se fera comme suit :
No Catalogue RF9536-N RF9537-N Groupage double 800 W/VA 800 W 600 W/VA Groupage triple 800 W/VA 800 W 600 W/VA Groupage simple 1 000 W/VA 1000 W 600 W/VA RF9540-N Charges INC/BTM EBT INC/EBT/FLR/
Halogne/BTM CFL/DEL 300 W 300 W 300 W Fonctionnement erratique ou DEL tremblotantes Les ampoules sallument aprs un long dlai Fonctions normalement utilises par les boutons-poussoirs du gradateur et non depuis le contrleur Z-Wave et un tmoin DEL bleue sallume et steint environ une fois la seconde Fonctions normalement utilises par la commande du gradateur gnral, mais non depuis le contrleur Z-Wave et aucun clignotement de DEL Fonctions normalement utilises par le contrleur Z-Wave local, mais contrlables par linterrupteur du gradateur accessoire (RF9542-Z) ou un autre dispositif Z-Wave Le gradateur est chaud au toucher aprs un certain temps Cause possible Solution A) Toutes les ampoules sont A) Remplacer lampoule grilles. B) Le disjoncteur est dclench C) Linterrupteur disolement B) Enclencher le disjoncteur C) Pousser linterrupteur du gradateur est en position OFF (teint). disolement du gradateur la position de tension D) Cblage inadquat E) Gradateur dfectueux A) Connexions de cblage lches D) Vrifier et corriger le cblage E) Remplacer le gradateur A) Vrifier et corriger le cblage B) Rgler lintensit minimum B) Rglage faible dintensit
(RF9540-N) un niveau plus lev
(RF9540-N) A) Caractristique dallumage A) Activer la caractristique B) Rglage faible dintensit B) Rgler lintensit minimum rapide dsactive
(RF9540-N)
(RF9540-N) dallumage rapide
(RF9540-N) un niveau plus lev
(RF9540-N) Gradateur non incorpor au rseau Z-Wave Problme avec les radiofrquences de communication du gradateur Le gradateur accessoire ou autre dispositif Z-Wave nest pas associ au gradateur de commande slectionn Ceci est normal Inclure le gradateur au rseau Z-Wave en utilisant un contrleur Z-Wave. Consulter le manuel dutilisation du contrleur Z-Wave pour obtenir tous les dtails Remplacer le gradateur Crer une association entre le gradateur accessoire ou autre dispositif et le gradateur. Consulter le manuel dutilisation du contrleur Z-Wave pour obtenir tous les dtails Aucune action requise Installation dune commande un seul emplacement (ncessite un gradateur gnral) 1.1 1.3 Nu arien Noir Noir chaud tiquette Blanc 1.41.2 1.5 1.3 Blanc Gnral Noir Vert tiquette Noir Rouge Noir Blanc Noir Vers luminaire Identifier le cblage existant (Cet interrupteur sera unipolaire) et tiqueter le fil conducteur. Utiliser un voltmtre si ncessaire pour confirmer le fil conducteur
(la tension du fil conducteur est prsente lorsque les tmoins sont teints.) 1.6 1.4 DESSUS Dbrancher linterrupteur existant et lenlever. Brancher le gradateur gnral comme illustr en raccordant le fil noir du gradateur au fil conducteur tiquet. Le fil rouge doit tre raccord au fil se dirigeant vers le luminaire. Pousser doucement le gradateur en place et scuriser avec les vis de montage. Sassurer que linterrupteur dbranch situ au bas du gradateur gnral est compltement enfonc. Conducteur 120V Noir Rouge Vert Mise la terre Neutre R E T S A M R E M M D I Blanc Blanc Luminaire Installation pour une commande depuis deux emplacements (ncessite un gradateur gnral et un gradateur accessoire) 2.4 2.3 Accessoire EMPLACEMENT A Blanc Noir tiquette Rouge Noir ACCESSOIRE ACCESSOIRE Vert Blanc Dbrancher linterrupteur existant et lenlever. Raccorder le gradateur accessoire lemplacement A, comme illustr. 2.1 2.1 Noir Rouge Nu arien tiquette Noir 2.2 2.2 Noir Blanc Rouge Nu arien Noir tiquette Blanc Identifier le cblage existant (les interrupteurs existants deviendront des interrupteurs 3 voies). tiqueter le fil commun des interrupteurs 3 voies (voir le chapitre Comment identifier les fils communs*). 2.5 2.4 R U E T A D A R G L A R N G Blanc Gnral Noir tiquette Rouge Noir Rouge Vert Noir REMARQUE : Le disjoncteur doit tre enclench (ON) pendant cette tape et les interrupteurs doivent tre rgls de manire ce que les ampoules soient teintes (OFF). Sassurer que tous les fils sont spars et scuritaires avant denclencher le disjoncteur
(ON). Raccorder le testeur entre les bornes communes tiquetes et la mise la terre dans lune des boites afin de dterminer lemplacement du gradateur accessoire. Si lessai dmontre une tension, celle-ci deviendra lemplacement A et sera utilise pour le gradateur accessoire. Si aucune tension nest dmontre, alors lautre emplacement 3 voies sera lemplacement A. REMARQUE :
Dbrancher toute alimentation lectrique aprs cette tape. Blanc Conducteur 120 V Vert Mise la terre Neutre R U E T A D A R G I E R O S S E C C A Noir Blanc Noir Cavaliers Rouge Blanc Blanc EMPLACEMENT A Rouge R U E T A D A R G L A R N G Noir Vert Mise la terre Blanc Luminaire Installation pour commande depuis trois emplacements (ncessite un gradateur gnral et deux gradateurs accessoires) 3.1 3.1 Rouge 3.2 3.2 Accessoire Emplacement 4 voies Rouge Noir Nu arien tiquette Noir tiquette tiquette Rouge Noir Blanc Blanc Vert Noir ACCESSOIRE Blanc Identifier le cblage existant (interrupteur 4 voies). tiquet le fil commun de linterrupteur 4 voies.
(voir le chapitre Comment identifier les fils communs*). Rouge Conducteur 120 V Neutre R U E T A D A R G I E R O S S E C C A Vert Mise la terre Rouge Cavaliers Noir Blanc Vert Mise la terre R U E T A D A R G I E R O S S E C C A Noir Cavaliers Noir Blanc Blanc Blanc Blanc Blanc EMPLACEMENT A Noir Vert R U E T A D A R G L A R N G Rouge Luminaire Mise la terre Blanc Raccorder le deuxime gradateur accessoire (interrupteur 4 voies), comme illustr. IMPORTANT! Identification des conducteurs communs*
Deux emplacements:
Chacun des interrupteurs comporte des conducteurs isols raccords trois vis de borne plus un fil vert ou nu raccord une vis de borne verte. Normalement, les trois bornes sont munies lune dune vis de couleur sombre et les deux autres dune vis de couleur claire (sans compter la vis verte). Ou alors les trois vis sont de la mme couleur et lune delles est repre COMMON ou COM (pour commun). Cherchez les conducteurs raccords aux vis de couleur sombre ou repres COMMON. Normalement ces fils sont noirs mais ils peuvent galement tre rouges ou bleus. tiquetez ces fils sur les deux interrupteurs pour les identifier lors du cblage. Trois emplacements:
Deux des interrupteurs existants sont des va-et vient, ils sont situs aux deux extrmits du circuit avec un interrupteur 4 voies entre-deux. TIQUETEZ les interrupteurs va-et-vient comme dcrit la section Commande partir de deux emplacements . Linterrupteur 4 voies comporte 4 fils isols raccords 4 vis de borne. TRS IMPORTANT REPREZ les deux fils isols de la mme couleur, lesquels sont raccords des vis de couleurs opposes. Consulter le point 1.4 pour pousser les gradateurs en place. GARANTIE LIMITE DE DEUX (2) ANS DES DISPOSITIFS DE CBLAGE COOPER Cooper Wiring Devices(CWD) garantit que le systme de gradation intelligent RF est exempt de dfauts de matriaux et de fabricant pour un usage et un service normaux pendant une priode de deux (2) ans compter de la date originale dachat. CETTE GARANTIE LIMITE DE DEUX (2) ANS REMPLACE TOUTES LES AUTRES GARANTIES, OBLIGATIONS OU OBLIGATIONS, EXPRESSES OU IMPLICITES (INCLUANT TOUTES GARANTIES IMPLICITES DE QUALIT MARCHANDE OU DADAPTATION UN USAGE PARTICULIER PENDANT LA PRIODE OUTREPASSANT LES DEUX [2] ANS SUIVANT LA DATE DACHAT DORIGINE PAR LE CONSOMMATEUR). AUCUN AGENT, REPRSENTANT OU EMPLOY DE CWD NEST AUTORIS ACCROTRE OU MODIFIER LES OBLIGATIONS DE CWD AU TITRE DE LA PRSENTE GARANTIE. Pour obtenir une rparation, au titre de la garantie, de tout systme de gradateur intelligent RF de CWD correctement install ayant t prouv comme tant dfectueux sous une utilisation normale, envoyer le systme de gradateur intelligent RF dfectueux en port prpay et assur : Quality Control Dept., Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269; Au Canada : Cooper Wiring Devices, 5 925 McLaughlin Road, Mississauga, Ontario L5R 1B8. CWD rparera ou remplacera, son gr, le dispositif dfectueux. CWD nest pas responsable, au titre de la prsente garantie, si lexamen dmontre quune dfectuosit du dispositif est cause par la mauvaise utilisation, labus, une installation incorrecte, une modification, un entretien inadquat ou une rparation de dommage d lenvoi CWD. CWD NE SERA PAS RESPONSABLE DE LINSTALLATION DU SYSTME DE GRADATION INTELLIGENT RF OU DE TOUTES BLESSURES, DOMMAGES MATRIELS OU DE TOUS DOMMAGES SPCIAUX, ACCIDENTELS, CASUELS OU ACCESSOIRES DE TOUTE NATURE, RSULTANT DES DFECTUOSITS DU SYSTME DE GRADATEUR INTELLIGENT RF OU DE TOUTES VIOLATIONS DE GARANTIE EXPRESSE OU IMPLICITE DE CE PRODUIT. LE SEUL RECOURS POUR VIOLATION DE LA PRSENTE GARANTIE LIMITE CONSISTE EN LA RPARATION OU LE REMPLACEMENT DU PRODUIT DFECTUEUX, AU GR DE CWD. LES GARANTIES IMPLICITES (SI EXISTANTES) INCLUANT, MAIS SANS Y TRE LIMIT, LES GARANTIES IMPLICITES DADAPTATION UN USAGE PARTICULIER ET DE QUALIT MARCHANDE, SONT LIMITES LA PRIODE DE DEUX (2) ANS SUIVANT LA DATE DACHAT DORIGINE PAR LE CONSOMMATEUR. EN AUCUN CAS, LA RESPONSABILIT DE CWD NE PEUT TRE SUPRIEURE AU PRIX DACHAT DUN AUTRE RECOURS PRESCRIT PAR LA LOI. Certaines provinces ne permettent pas lexclusion ou la limitation de dommages accessoires ou indirects ou les noncs ou modifications des limitations de dure dune garantie implicite, dans quel cas, ces limitations ne sappliquent peut-tre pas vous. Certaines provinces canadiennes ne permettent pas lexclusion ou la divergence des garanties implicites et il se pourrait que certaines des limitations ci-dessus ne vous concernent pas. Cette garantie vous donne des droits lgaux prcis et vous pourriez avoir dautres droits selon la province o vous rsidez. Lire attentivement les instructions fournies. Pour toutes questions au sujet de lutilisation ou de lentretien de ce produit, crire : Consumer Service Division, Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269. RFAL-DIMR-SP (REV. B) ESPAOL IN U.S.A.: Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269 866-853-4293 ATENUADOR RF SMART RF9540-N Para LED atenuante/CFL/incandescente/MLV/ELV/halgeno/fluorescente atenuante RF9536-N Para incandescente/MLV RF9537-N para Accesorios de iluminacin ELV / RF9542-Z Accesorio RF para ubicaciones mltiples INSTRUCCIONES DE INSTALACIN ADVERTENCIA:
Apague el disyuntor o quite los fusibles y compruebe que la energa est apagada antes del cableado. Nunca cablee un dispositivo elctrico con la energa encendida. Cablear el atenuador con energa puede provocar daos permanentes en el atenuador y anular la garanta. Si no est seguro acerca de alguna parte de estas instrucciones, comunquese con un electricista calificado. IMPORTANTE:
El atenuador RF Smart no funcionar o se daar si se cablea incorrectamente, y se anular la garanta. Consulte las instrucciones de cableado provistas en el lado opuesto. INSTRUCCIONES DE FUNCIONAMIENTO Presione una vez para encender las luces en el nivel previamente seleccionado. Vuelva a presionar para apagar las luces. Cuando las luces estn apagadas, presione y mantenga presionado durante 2 segundos para obtener un brillo completo. Cuando las luces estn encendidas, presione y mantenga presionado durante 2 segundos hasta que parpadee el LED azul. Despus de la demora preestablecida, las luces comenzarn a atenuar hasta apagarse (hasta 4 minutos). El LED de Encendido/apagado mbar indica que el atenuador est encendido. AJUSTE DEL NIVEL DE ATENUACIN (RF9540-N nicamente) Para lograr una mxima compatibilidad con distintos tipos de carga, el RF9540-N permite al usuario establecer el nivel mnimo. Tambin, para ahorrar en consumo de energa, el RF9540-N permite al usuario establecer el nivel mximo. 1. Despus de instalar el atenuador y restaurar la energa. 2. Presione el botn de encendido/apagado para encender la luz. 3. Presione y mantenga presionado el botn de encendido/apagado durante cinco segundos hasta que los LED azules del atenuador comiencen a cambiar rpidamente (AVISO: despus de dos segundos, los LED azules del atenuador comenzarn a parpadear, indicando la activacin de la funcin de desactivacin de demora. Contine manteniendo presionado el botn de encendido/apagado durante tres segundos adicionales hasta que los LED azules del atenuador comiencen a cambiar rpidamente). 4. Suelte el botn. El atenuador establecer la luz al nivel mnimo previamente guardado (es posible que la luz parpadee o se apague). Durante la configuracin inicial, la luz se establecer en el valor mnimo predeterminado de fbrica. 5. Presione el botn para atenuar o brillar para cambiar el nivel mnimo hasta que la salida de luz 6. Presione el botn de encendido/apagado. Los LED azules del atenuador comenzarn a cambiar rpidamente de nuevo y la luz del atenuador se establecer en el nivel mximo previamente guardado. 7. Presione el botn para atenuar o brillar para cambiar el nivel mximo hasta que la salida de 8. Presione el botn de encendido/apagado, el LED parpadear indicando que el programa est sea aceptable. luz sea aceptable. completo NOTA: Para restaurar el valor mximo/mnimo predeterminado, repita los pasos anteriores y ajuste los niveles de luz a los valores completos de mnimo/mximo presionando el botn atenuar/brillar hasta que la salida de luz ya no cambie. NOTA: el usuario puede omitir el establecimiento de los valores mximo o mnimo presionando el botn de encendido/apagado sin cambiar el nivel del atenuador. Funcin de arranque rpido (RF9540-N nicamente) Esta funcin garantiza que las luces LED/CFL se enciendan cuando el nivel preestablecido del atenuador sea bajo. Cuando est habilitada esta configuracin, las luces pueden brillar ms que el nivel preestablecido momentneamente (menos de un segundo) y luego atenuarse al nivel preestablecido. Es posible que esta funcin no sea necesaria, segn el tipo de luz que utilice. Para habilitar/deshabilitar esta funcin, encienda las luces. Presione y mantenga presionado el botn de encendido/apagado durante 10 segundos hasta que los LED azules del atenuador parpadeen por tercera vez, luego suelte el botn. PRECAUCIN:
1. Utilice solo con 120 V AC 60 Hz. 2. No exceda la calificacin mxima del atenuador, segn lo indicado en el dispositivo. 3. Debe instalarse y utilizarse segn los cdigos elctricos. 4. Si no dispone de una conexin a tierra de cobre o verde descubierta en la caja de la pared, comunquese con un electricista calificado para la instalacin. 5. Utilice solo cables de cobre N. 14 o N. 12 calificados para al menos 75C con estos dispositivos. No lo utilice con cables de aluminio. NOTAS:
1. El atenuador RF Master se cablea directamente al accesorio de iluminacin. 2. El atenuador RF Smart no es compatible con interruptores estndares de 3 vas. 3. Para aplicaciones de mltiples ubicaciones (3 vas o 4 vas), el atenuador de accesorios RF Smart se utiliza junto con un atenuador RF Master. 4. El atenuador de accesorios RF se comunica a travs de seales de RF para controlar la luz desde ms de una ubicacin. 5. Para el control de mltiples ubicaciones, utilice el atenuador maestro RF Smart directamente cableado a la luz junto con el accesorio RF (RF9542-Z). El accesorio RF no requiere conexin directa con la luz (utilice la funcin de Asociacin). 6. Cuando instale ms de un atenuador en una caja de pared, no es necesario reducir el vatiaje total de las lmparas. Consulte el grfico Instalacin de juegos. INSTALACIN DE JUEGOS Cuando instale juegos de mltiples Atenuadores maestros Smart en una caja de pared, se necesita disminuir la potencia de la siguiente manera N. de catlogo RF9536-N RF9537-N Juego simple 1.000 W/VA 1.000 W 600 W/VA Juego doble 800 W/VA 800 W 600 W/VA Juego triple 800 W/VA 800 W 600 W/VA RF9540-N Cargas INC/MLV ELV INC/ELV/FLR/
Halgeno/MLV CFL/LED 300 W 300 W 300 W Instrucciones de instalacin de red del dispositivo Z-Wave 1. Este producto puede agregarse a una red Z-Wave nueva o existente. Un dispositivo Z-Wave Cooper Wiring Devices posee un LED azul que parpadea cuando el dispositivo no est incluido en una red Z-Wave. El LED deja de parpadear cuando el dispositivo est en la red. 2. Para incluir este dispositivo en una red Z-Wave, seleccione el comando en el controlador Z-Wave para inclusin (Instalar, agregar dispositivo, agregar nodo, incluir dispositivo, etc.). Luego presione el interruptor del dispositivo una vez para incluirlo en la red. El LED dejar de parpadear. 3. Para excluir este dispositivo de una red Z-Wave, seleccione el comando en el controlador Z-Wave para exclusin (Desinstalar, quitar dispositivo, quitar nodo, excluir dispositivo, etc.). Luego presione el interruptor del dispositivo una vez para excluirlo de la red. El LED comenzar a parpadear. 4. Este producto funciona con otros productos Z-Wave de distintos proveedores y categoras de productos como parte de la misma red. 5. Este producto es un nodo de escucha y acta como repetidor en la red Z-Wave. Llevar a cabo la funcin de repeticin con productos Z-Wave de Cooper y de otros fabricantes de Z-Wave. Botn de encendido/apagado Presione para iluminar El nivel de luz puede ajustarse con las luces encendidas o apagadas Presione para ATENUAR Indicadores de nivel de luz (azul) Indicador LED de encendido/apagado
(mbar) Interruptor de desconexin Tire para cambiar las bombillas (Atenuador maestro nicamente) LEA ANTES DE LA INSTALACIN!
Identificacin del interruptor Blanco Blanco ACCESORIO ACCESORIO Verde j o o R ACCESORIO Verde Interruptor de desconexin Negro Control maestro Negro Accesorio Gua de solucin de problemas Causa posible Sntoma A) Las bombillas estn quemadas B) El disyuntor est apagado o desconectado C) El interruptor de desconexin del atenuador est en la posicin de apagado D) Cableado incorrecto E) Atenuador defectuoso A) Conexiones de cableado sueltas B) Establecimiento de atenuacin baja (RF9540-N) A) Est deshabilitada la funcin de arranque rpido
(RF9540-N) B) Establecimiento de atenuacin baja (RF9540-N) El atenuador no se incluye en la red de Z-Wave Problema con la comunicacin RF en el atenuador Solucin A) Reemplace la bombilla B) Encienda el disyuntor C) Empuje el interruptor de desconexin en el atenuador D) Verifique y corrija el cableado E) Reemplace el atenuador A) Verifique y corrija el cableado B) Establezca el brillo mnimo a un nivel ms alto (RF9540-N) A) Habilite la funcin de arranque rpido (RF9540-N) B) Establezca el brillo mnimo a un nivel ms alto (RF9540-N) Incluye el atenuador en una red de Z-Wave mediante un controlador de Z-Wave. Consulte el manual del usuario del controlador Z-Wave para obtener detalles Reemplace el atenuador El accesorio de atenuador u otro dispositivo Z-Wave no est asociado con el atenuador que desea controlar Cree una asociacin entre el accesorio de atenuador u otro dispositivo y el atenuador. Consulte su manual del usuario del controlador Z-Wave para obtener detalles Esto es normal No se requiere ninguna accin No funciona. Todos los LED estn apagados. Funcionamiento errtico o parpadeo de los LED Las luces de encienden despus de una larga demora Funciona normalmente usando los botones pulsadores del atenuador pero no desde el controlador Z-Wave y uno de los LED azules parpadea al menos una vez por segundo Funciona normalmente utilizando el control de atenuador Master, pero no desde el controlador Z-Wave y no hay LED que parpadeen Funciona normalmente de manera local y desde un controlador Z-Wave, pero no puede controlarse desde un interruptor de accesorio de atenuador (RF9542-Z) u otro dispositivo Z-Wave El atenuador est caliente al tacto despus de un perodo de tiempo Instalacin de control de una sola ubicacin (requiere un atenuador Master) 1.1 1.3 Descubierto Negro
- Vivo negro Etiqueta
-
Negro Para iluminar Blanco 1.41.2 Identifique el cableado existente (este interruptor ser de un solo polo) y etiquete el cable Vivo. Utilice un medidor de voltaje segn sea necesario para confirmar que es el cable Vivo (habr voltaje en el cable Vivo cuando las luces estn apagadas). 1.6 1.4 PARTE DE ARRIBA Desconecte el interruptor existente y extrigalo. 1.3 1.5 Blanco Maestro Negro Verde Etiqueta Negro Rojo Negro Blanco Conecte el atenuador maestro como se muestra en la figura conectando el cable negro del atenuador al cable Vivo etiquetado. El cable rojo debe conectarse al cable que va a la luz. Presione levemente el atenuador en su lugar y asegure con tornillos de montaje. Asegrese de que el interruptor de desconexin de la parte inferior del maestro est completamente presionado Vivo 120V Negro Rojo R E T S A M R E M M D I Blanco Verde Neutro Tierra Blanco Accesorio de iluminacin Instalacin de control de dos ubicaciones (requiere un maestro y un accesorio) 2.1 2.1 Negro Rojo Descubierto Etiqueta Negro 2.2 2.2 Negro Blanco Rojo Descubierto Negro Etiqueta 2.4 2.3 Accesorio UBICACIN A Negro Etiqueta Rojo Negro Blanco Blanco ACCESORIO ACCESORIO Verde Blanco Desconecte el interruptor existente y extrigalo. Conecte el atenuador accesorio en la Ubicacin A como se muestra en la figura. Identifique el cableado existente (ambos interruptores existentes sern de 3 vas). Etiquete el cable comn en ambos interruptores de 3 vas (consulte la seccin Cmo identificar los cables comunes)*
2.5 2.4 Maestro Rojo Verde Negro Etiqueta R O D A U N E T A O R T S E A M Blanco Rojo Blanco Negro Negro NOTA: El disyuntor debe estar encendido durante este paso, y los interruptores deben establecerse para que la luz est apagada. Asegrese de que todos los cables ests separados de manera segura antes de encender el disyuntor. Conecte el medidor entre el terminal comn etiquetado y el conector a tierra en una de las cajas para determinar la ubicacin del atenuador accesorio. Si la medicin indica que hay voltaje, entonces esa ser la Ubicacin A, y se utilizar para el Atenuador accesorio. Si no hay voltaje, entonces la Ubicacin A ser la otra de 3 vas. NOTA: Desconecte la alimentacin despus de este paso. Vivo 120 V Neutro Negro Negro Cables de traslacin Rojo R O D A U N E T A I O R O S E C C A Verde Blanco Tierra Blanco Blanco UBICACIN A Rojo R O D A U N E T A O R T S E A M Negro Verde Tierra Blanco Accesorio de iluminacin Instalacin de control de tres ubicaciones (requiere un maestro y dos atenuadores accesorios) 3.1 3.1 Rojo 3.2 3.2 Accesorio Ubicacin de 4 vas Conecte el segundo atenuador accesorio (interruptor de 4 vas ) como se muestra en la figura. Negro Rojo Descubierto Etiqueta Negro Etiqueta Etiqueta Rojo Negro Blanco Blanco Verde Negro ACCESORIO Identifique el cableado existente (interruptores de 4 vas). Etiquete el cable comn en el interruptor de 4 vas. (consulte la seccin Cmo identificar los cables comunes)*
Blanco Rojo Vivo 120 V Tierra Neutro R O D A U N E T A I O R O S E C C A Verde Blanco Blanco Blanco UBICACIN A Rojo Cables de traslacin Negro Verde Tierra Blanco R O D A U N E T A I O R O S E C C A Blanco Negro Cables de traslacin Negro Blanco Negro Verde R O D A U N E T A O R T S E A M Rojo Accesorio de iluminacin Tierra Blanco IMPORTANTE! Identificacin de los conductores comunes*
Dos ubicaciones:
Cada interruptor tiene cables aislados conectados a tres tornillos terminales ms un cable verde o desnudo conectado a un tornillo terminal verde. Uno de los terminales es un tornillo de color oscuro y los otros dos son tornillos de color claro (no tome en cuenta el tornillo verde). Alternativamente los tres tornillos pueden ser del mismo color y uno tendr marcado la palabra COMMON (COMN) o COM. Busque los alambres conectados a los tornillos oscuros o denominados COMN. Generalmente estos alambres son de color negro pero pueden ser rojos o azules. Etiquete estos alambres en los dos interruptores para identificarlos cuando realice las conexiones. Tres ubicaciones:
Dos de los interruptores existentes deben ser de 3 posiciones. Los interruptores de 3 posiciones se instalan en los extremos del circuito con un interruptor de 4 posiciones entremedio. ETIQUETE los dos interruptores de 3 posiciones segn la seccin Control desde dos ubicaciones. El interruptor de 4 posiciones tiene 4 alambres aislados conectados a 4 tornillos terminales. MUY IMPORTANTE ETIQUETE los dos alambres aislados del mismo color que estn conectados a tornillos de colores opuestos. Consulte 1.4 para presionar los atenuadores en su lugar. GARANTA LIMITADA DE 2 AOS DE COOPER WIRING DEVICES Cooper Wiring Devices (CWD) garantiza que el sistema de atenuador RF Smart est libre de defectos en material y mano de obra durante el uso normal y el servicio por un perodo de dos aos a partir de la fecha de compra original. ESTA GARANTA LIMITADA DE DOS (2) AOS REEMPLAZA A TODAS LAS DEMS GARANTAS, OBLIGACIONES O RESPONSABILIDADES, EXPRESAS O IMPLCITAS (INCLUIDA CUALQUIER GARANTA IMPLCITA DE COMERCIALIZACIN O ADAPTACIN PARA UN PROPSITO EN PARTICULAR QUE EXCEDA EN DURACIN LOS DOS AOS A PARTIR DE LA FECHA DE LA COMPRA ORIGINAL POR PARTE DEL CONSUMIDOR). NINGN AGENTE, REPRESENTANTE O EMPLEADO DE CWD POSEE AUTORIDAD PARA AUMENTAR O MODIFICAR LAS OBLIGACIONES DE CWD BAJO ESTA GARANTA. Para obtener servicio de garanta para cualquier sistema de atenuador RF Smart de CWD correctamente instalado que se compruebe es defectuoso durante el uso normal, enve el sistema de atenuador RF Smart prepago y asegurado al Departamento de Control de calidad, Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269; en Canad:Cooper Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8. CWD reparar o reemplazar la unidad defectuosa a su discrecin. CWD no ser responsable bajo esta garanta si el examen demuestra que la condicin defectuosa de la unidad fue provocada por mal uso, abuso, instalacin incorrecta, alteracin, mantenimiento inadecuado o reparacin de daos durante el envo a CWD. CWD NO TIENE RESPONSABILIDAD POR LA INSTALACIN DEL SISTEMA DE ATENUADOR RF SMART, O POR NINGUNA LESIN PERSONAL, DAO A LA PROPIEDAD O CUALQUIER DAO ESPECIAL, INCIDENTAL, CONTINGENTE O CONSECUENTE DE NINGN TIPO, QUE RESULTE DE DEFECTOS EN EL SISTEMA DE ATENUADOR RF SMART O POR LA VIOLACIN DE CUALQUIER GARANTA EXPRESA O IMPLCITA DE ESTE PRODUCTO. EL NICO RECURSO PARA LA VIOLACIN DE LA GARANTA LIMITADA CONTENIDA AQU ES LA REPARACIN O REEMPLAZO DEL PRODUCTO DEFECTUOSO A DISCRECIN DE CWD. LAS GARANTAS IMPLCITAS (SI EXISTIESEN) INCLUYEN, ENTRE OTRAS, LAS GARANTAS IMPLCITAS DE ADAPTACIN PARA UN PROPSITO EN PARTICULAR Y DE COMERCIALIZACIN, SON LIMITADAS EN DURACIN A UN PERODO QUE FINALIZA DOS AOS DESPUS DE LA FECHA DE LA COMPRA ORIGINAL POR PARTE DEL CONSUMIDOR. BAJO NINGUNA CIRCUNSTANCIA LA RESPONSABILIDAD DE CWD BAJO CUALQUIER OTRO RECURSO PRESCRIPTO POR LA LEY EXCEDER EL PRECIO DE COMPRA. Algunos estados no permiten la exclusin o limitacin de los daos incidentales o consecuentes o permiten exenciones de responsabilidad o modificaciones de las limitaciones sobre la duracin de una garanta implcita, de manera que es posible que las limitaciones anteriores no se apliquen. Algunas provincias de Canad no permiten la exclusin o variacin de las garantas implcitas, de manera que es posible que algunas o todas las limitaciones anteriores no se apliquen. Esta garanta le otorga derechos legales especficos y es posible que cuente con otros derechos que pueden variar segn el estado y la provincia. Lea las instrucciones adjuntas con cuidado. Si tiene alguna pregunta relacionada con el uso o el cuidado de este producto, escriba a:Divisin de servicio al consumidor, Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269. Z-Wave Device Network Installation Instructions This product may be added to a new or existing Z-Wave network. A Z-Wave device has a blue LED which will blink when the device is not included in a Z-Wave network. The LED will not blink when the device is in a network. To include this device in a Z-Wave network, select the command on your Z-Wave controller for inclusion (Install, Add Device, Add Node, Include Device, etc.). Then press the device switch one time to include it in the network. The LED will quit blinking. To exclude this device from a Z-Wave network, select the command on your Z-Wave controller for exclusion (Uninstall, Remove Device, Remove Node, Exclude Device, etc.). Then press the device switch one time to exclude it from the network. The LED will start blinking. This product works with other Z-Wave products from different vendors and product categories as part of the same network. This product is a listening node and it will act as a repeater in the Z-Wave network. It will perform the repeater function with Z-Wave products from Eaton and from other Z-Wave vendors. Instructions dinstallation sur rseau dappareils Z-Wave Ce produit peut tre ajout un rseau Z-Wave nouveau ou existant. Les appareils Z-Wave de sont munis dune diode lectrolumi-
nescente bleue qui clignote sils ne sont pas connects un rseau Z-Wave. La diode ne clignote pas quand lappareil est connect un rseau. Pour ajouter cet appareil un rseau Z-Wave, choisissez le menu daddition dappareil sur votre commande Z-Wave (Installer
[Install], Ajouter Appareil [Add Device], Ajouter Nud [Add Node], Inclure Appareil [Include Device], etc.). Appuyez ensuite une fois sur le bouton de lappareil pour lajouter au rseau. La diode cessera alors de clignoter. Pour exclure cet appareil dun rseau Z-Wave, choisissez le menu sur votre commande Z-Wave correspondant lexclusion
(Dsinstaller [Uninstall], Enlever Appareil [Remove Device], Enlevez Noeud [Remove Node], Exclure Appareil [Exclude Device], etc.). Appuyez ensuite une fois sur le bouton de lappareil pour lexclure du rseau. La diode commencera alors clignoter. Ce produit fonctionne avec dautres produits Z-Wave de fabricants et types varis qui font partie du mme rseau. Ce produit est un nud rcepteur et il se comporte en rpteur au sein dun rseau Z-Wave. Cette fonction de rpteur est prsente avec les produits Z-Wave de Eaton ainsi que ceux dautres fabricants de Z-Wave. Instrucciones de instalacin en una red de dispositivos Z-Wave Este producto puede agregarse a una red Z-Wave existente o nueva. Un dispositivo Z-Wave de tiene un diodo LED azul que parpadea cuando el dispositivo no est incluido en la red Z-Wave. El diodo LED no parpadear cuando el dispositivo est en la red. Para incluir este dispositivo en una red Z-Wave, seleccione la orden correspondiente en el controlador Z-Wave para incluirlo
(Instalar [Install], Agregar dispositivo [Add Device], Agregar nodo [Add Node], Incluir dispositivo [Include Device], etc.). Luego oprima el interruptor del dispositivo una vez para incluirlo en la red. El diodo LED dejar de parpadear. Para excluir este dispositivo de una red Z-Wave, seleccione la orden correspondiente en el controlador Z-Wave para excluirlo
(Desinstalar [Uninstall], Retirar dispositivo [Remove Device], Retirar nodo [Remove Node], Excluir dispositivo [Exclude Device], etc.). Luego oprima el interruptor del dispositivo una vez para excluirlo de la red. El diodo LED empezar a parpadear. Este producto funciona con otros productos Z-Wave de diversos proveedores y distintas categoras de productos que forman parte de la misma red. Este producto es un nodo de escucha y actuar como un repetidor en la red Z-Wave. Realizar la funcin de repetidor con productos Z-Wave de Eaton y de otros proveedores de productos Z-Wave. 7.3 BLACK 0/0/0/100 ARTWORK PROOF# 1 Lori Marcum 1. Author/Designer 2. Marketing Specialist 3. Engineering 5.4 4. Codes & Standards 5. Product Line Manager 6. Retail 7. Packaging Manager 8. Marketing Communication Manager 9. Associate Director of Marcom 12/5/17 Date Date Date Date Date Date Date Date Date Date release to Vendor/PDF to shared drive RF600ZW-PTA (REV.C) PART #:
DIE VINYL PART#:
REF #: TI3101D-PTA REVISION LEVEL: REV. C - Initial Artwork Release Eaton Wiring Devices Peachtree City, GA 30269 Eaton.com Eaton.com/wiringdevices RF600ZW-PTA (REV. C) This device complies with Industry Canadas licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) lappareil ne doit pas produire de brouillage;
(2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1: This device may not cause harmful interference, and 2: This device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC CAUTION:
Any changes or modications not expressly approved by Eaton Wiring Devices could void the users authority to operate the equipment. 5.4 7.3 FOR REFERENCE ONLY
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2017-12-22 | 908.4 ~ 908.4 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2017-12-22
|
||||
1 | Applicant's complete, legal business name |
Cooper Wiring Devices Inc
|
||||
1 | FCC Registration Number (FRN) |
0015363989
|
||||
1 | Physical Address |
203 Cooper Circle
|
||||
1 |
Peachtree City,, GA
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
T******@intertek.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
UH2
|
||||
1 | Equipment Product Code |
RF9540-N
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
E****** G****
|
||||
1 | Telephone Number |
77063********
|
||||
1 | Fax Number |
77063********
|
||||
1 |
e******@eaton.com
|
|||||
app s | Technical Contact | |||||
1 | Firm Name |
Cooper Wiring Devices Inc
|
||||
1 | Name |
E******** G********
|
||||
1 | Physical Address |
203 Cooper Circle
|
||||
1 |
Peachtree City, Georgia 30269
|
|||||
1 |
United States
|
|||||
1 | Telephone Number |
770 6********
|
||||
1 | Fax Number |
770 6********
|
||||
1 |
E******@Eaton.com
|
|||||
app s | Non Technical Contact | |||||
1 | Firm Name |
Cooper Wiring Devices Inc
|
||||
1 | Name |
E******** G******
|
||||
1 | Physical Address |
203 Cooper Circle
|
||||
1 |
Peachtree City, Georgia 30269
|
|||||
1 |
United States
|
|||||
1 | Telephone Number |
770 6********
|
||||
1 | Fax Number |
770 6********
|
||||
1 |
E******@Eaton.com
|
|||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | RF AC Operated Dimmer Switch | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Intertek Testing Services NA Inc.
|
||||
1 | Name |
C******** P******
|
||||
1 | Telephone Number |
972-2********
|
||||
1 | Fax Number |
67877********
|
||||
1 |
c******@intertek.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 908.40000000 | 908.40000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC