all | frequencies |
|
exhibits | applications |
---|---|---|---|---|
manual |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
Users Manual | Users Manual | 1.62 MiB | July 03 2019 | |||
1 | Cover Letter(s) | July 03 2019 | ||||||
1 | Cover Letter(s) | July 03 2019 | ||||||
1 | Cover Letter(s) | July 03 2019 | ||||||
1 | External Photos | July 03 2019 | ||||||
1 | ID Label/Location Info | July 03 2019 | ||||||
1 | ID Label/Location Info | July 03 2019 |
1 | Users Manual | Users Manual | 1.62 MiB | July 03 2019 |
ENGLISH RF96PIRBMS - Z-WAVE PLUS MOTION SENSOR The Motion Sensor is a Z-WaveTM enabled device which is fully compatible with any Z-WaveTM enabled network. The device can be set up in a Z-Wave network to communicate directly with other end devices such as switches or dimmers, or to connect to a Z-Wave controller such as Eatons Home Automation Hub or other Z-Wave certified controllers. This product supports the S2 security protocol that uses encrypted Z-Wave Plus messages to communicate to other security-enabled Z-Wave Plus products. A security-enabled Z-Wave Plus Controller must be used in order to fully utilize the security features of this product. The Motion Sensor is designed with two detecting sensors, Passive Infra-Red (PIR) sensor and ambient light sensor, in order to optimize its performance for both security and home automation applications. For security applications, the sensor will transmit a signal to a controller when any motion is detected within the devices field of view which could trigger an alarm or some other notification. For home automation, the sensor can be used turn lights ON or OFF as someone enters or leaves a room or area. It includes a timeout timer that can automatically turn lights OFF when it no longer detects motion after a configurable amount of time. The light sensor allows the system to be configured to implement different actions based on the ambient light level (such day vs. night). The Motion Sensor uses a CR123 3.0V Lithium battery, which under normal conditions, will have a battery life of up to 2 years. When the battery level drops to an unacceptable level, the sensor will emit a low battery message to the Z-Wave controller. When this occurs the batteries should be replaced as soon as possible Product Overview Quick Test Prior to mounting the device, it is recommended that device is placed in test mode to find the optimal positioning of the sensor 1. If the rear cover is attached, remove the rear cover using a screwdriver. 2. With the rear cover detached, the tamper switch will be in the open position, and the unit will enter Test Mode. 3. During Test Mode, if movement is detected, the LED on the sensor will light up once implying the unit is working properly, and it will retrigger about every 5 seconds if motion is detected. During this mode, you can also test the range and positioning to make sure it is placed in an optimal location (see Choosing the Location section). 4. To exit the Test mode, simply press the Tamper switch for more than 10 seconds or simply replace the rear cover which causes the Tamper switch to be depressed. 5. During normal mode, when PIR is triggered, the red LED will not light up and retrigger time is based on set up value. Mounting the Sensor Choosing the location The PIR Sensor is suitable for mounting in dry indoor locations only. The recommended position for a PIR Sensor is in the corner of a room mounted at a height between 5.9ft and 6.6ft. At this height, the sensor will have a maximum range of up to 30ft with a field of view of 120, subject to the position for the sensor being set in position 5. (see FIGURES 1 & 2) The position of the PCB inside the sensor can be set to 5 different positions to adjust the range of the sensor. Setting the PCB in position 3 will reduce the range to approximately 20ft, with position 1 providing a range of approximately 10ft. The recommended position setting for the sensor is in position 5. The position should be set based on the desired range of the user. 30ft 20ft 10ft Figure 1 Installing and Adding to Z-WaveTM Network Auto Inclusion The sensor supports Auto Inclusion feature where it will automatically enter Inclusion mode when first powered up after a factory reset. 1. Use a screwdriver to detach the rear cover. Figure 2 6.6 ft PCB Position 1 3 5 Range 10ft (3m) 20ft (6m) 30ft (9m) Rear Cover 2. Put a Z-Wave Controller into inclusion mode. 3. Insert 1 CR123 3V battery to the battery compartment with the correct polarity. The LED on the device should turn ON. Fixing Screw 4. The Inclusion process should be completed when the LED stops blinking. 5. Do not refit the rear cover yet and proceed to the Testing section before mounting. Note: If Auto Inclusion fails, refer to the Troubleshooting section regarding Manual Inclusion. Testing Warm-Up It will take approximately 2 minutes for the sensor to warm up after a battery is inserted. During this period the LED behind the lens will turn ON. When the red LED turns OFF, it implies that the warm-up procedure is completed and the sensor is ready for detection. Note: This will not affect the Inclusion/Exclusion process. Note: After removing batteries, wait for 5 seconds to refit batteries. When determining the mounting position for the sensor the following points should be considered to ensure trouble-free operation:
1. Do not locate the sensor facing a window or where it is exposed to or facing direct sunlight. 2. Do not locate the sensor near air vents. 3. Do not locate the sensor directly above a heat source, (e.g. fire, radiator, boiler, etc). 4. Do not locate the detector in a position where it is subject to excessive vibration 5. Where possible, mount the sensor in the corner of the room so that the logical path of a person would cut across the fan detection pattern. PIR sensors respond more effectively to movement across the device than to movement directly towards it. (FIGURE 3). Less Sensitive Figure 3 More Sensitive Good Sensitivity 6. Ensure that the position selected for the PIR sensor is within effective range of the system, (refer to System Installation and Operating Manual). Installation Before mounting, ensure that the sensor PCB position is set to the correct position to provide the desired detection range. To adjust the range, simply slide the PCB up or down ensuring the position legs are aligned with the required position number marked on the board. The Motion Sensor can be mounted using either the provided dual-sided adhesive or screws. For installation using dual-sided adhesive:
1. Remove one side of the adhesive cover and attach appropriately to the rear of the device. For corner mounting, it is recommended to cut the adhesive into two pieces and place on each angled side to ensure a better fit. 2. Remove the other side of the adhesive cover, place the device in its desired location, and apply pressure until the device is secure. For installation using screws:
1. Carefully drill out the required mounting holes in the rear cover using 3mm drill according to whether the unit is being mounted in a corner or against a flat wall. Note: Use the 1st mounting hole positions for corner mounting installation, and use the 2nd mounting hole positions for flat wall installation. (see FIGURE 4a & 4b) 2nd Mounting Hole Positions 1st Mounting Hole Positions Corner Mounting Figure 4a Figure 4b 2. Using the rear cover as a template, mark the positions of the fixing holes on the wall. 3. Fix the rear cover to the wall using the two 18mm No.4 screws and 25mm wall anchors, (a 5mm hole will be required for the wall anchors). Do not over-tighten the fixing screws as this may distort or damage the cover. 4. Fit the sensor onto the rear cover by placing the clips on the top edge into the rear cover. Push the lower edge of the sensor into place and refit the fixing screw in the bottom edge of the sensor to secure in position. Do not over-tighten the fixing screws as this may damage the casing. Once the device is mounted and installed in a Z-Wave network, ensure that motion is properly detected and the associated devices and/or controller are activated appropriately. Programming Z-Wave Group The sensor supports either one of two Z-Wave Association Groups:
Group 1: Association with 1 Controller node. Group 2: Association with 4 nodes (i.e. end devices such as switches or dimmers). This allows the sensor to transfer commands directly to end devices without having to go through the controller. Group 1 commands:
When the unit is powered up and is already a part of a Z-Wave network, the unit will send a Notification Report to the node in Group 1. When the unit senses motion, the unit will send a Notification Report to the nodes of Group 1. Once the movement is stopped, a Notification Report will be sent again to Group 1. When the sensor status changes, the unit will check its battery status simultaneously. When the battery level of the unit is low, the unit will emit a Battery report to the nodes of Group 1 When performing Factory Reset the unit will send Device Reset Locally Notification to the node of Group 1. Group 2 commands:
When the sensor is triggered, the unit will send BASIC_SET command which contains a value to the nodes of Group 2. AGI (Association Group Information) Table Command Class &
Command (List) N bytes Battery Report, Notification Report Device Reset Locally Notification Basic Set Group Name Lifeline PIR Control Function ON-OFF Duration Event Parameters Length Event Parameters Detector is triggered 0x00 0x00 0x01 0x01 0x01 0x08 0x03 Group 1 2 Notification Event The power is applied for the first time PIR Trigger ON PIR Trigger OFF Tamper switch being pressed more than 10 seconds Tamper switch being pressed more than 10 seconds and released Battery Battery Report (value) 20 ~ 100 0xFF Profile General Control Type 0x08 0x07 0x07 0x07 0x07 Description Battery Level (%) Low Battery Event 0x01 0x08 0x00 0x00 0x03 1 of 2 1. Basic Set Level The Basic Set Level determines the value that will be sent from the Basic Set command for devices associated with Group 2. For a Binary Switch Device (e.g., receptacle or appliance module), it will be a simple ON command. For a Multilevel Switch Device (e.g., a dimmer), it will be set to the level set by this parameter. Example:
1-99: ON (Binary Switch Device) Dim Level (Multilevel Switch Device) Function Basic Set level Parameter Number 1 Size 1 Range 1 ~ 99 Default 99 2. Sensitivity Level (PIR sensor only) In order to provide the best efficiency of the sensor, it is recommended to test the sensor with movements from the farthest end of the coverage area at first time of use. If movements cannot be detected consistently, simply adjust the sensitivity level with Configuration Parameter #3. This parameter can be configured with the value of 1 through 10, where 1 means low sensitivity and 10 means high sensitivity. Function Sensitivity Level Parameter Number 3 Size 1 Range 1 ~ 10 Default 6 3. Re-trigger Interval Setting (PIR sensor only) The Re-trigger Interval Setting determines the amount of time between when the sensor will re-
trigger a signal that motion has been detected. During this time, the sensor will not report motion even though motion may be detected. The time interval can be set between 5 secs to 3600 secs. Function Re-trigger Interval Parameter Number 4 Range 5~3600 (sec) Default 180 Size 2 Triggered Detected a movement 4. Lux Level 180 seconds Detected a movement
(no response)
(no response) Triggered Detected a movement The user can set a lux level percentage which determines when the light sensor will be activated. If the lux level of ambient illumination falls below this percentage, and motion is detected, the sensor will emit a Z-Wave ON Command to the controller. Percentage can be set between 1% to 100%. Function Lux Level Parameter Number 5 Size 1 Range 1 ~ 100%
Default 20 5. On-Off Duration The function of on-off duration setting will be useful if the detector is connected with a module or lighting. The duration determines how long the module/lighting should stay ON. For instance, Lamp Module turns OFF 100 secs after it has been turned ON. This parameter can be configured with the value of 5 through 3600, where 5 means 5 second delay and 3600 means 3600 seconds of delay. Parameter Number 6 Light turns on 15 seconds Size 2 Range 5-3600 (sec) Default 15 Light turns off Detected a movement Troubleshooting Guides The table below lists the several steps involved when adding or removing the unit from the Z-Wave network. Action/Status No node ID Auto Inclusion Manual Inclusion Exclusion Description The Z-Wave Controller does not allocate a node ID to the unit The power is applied for the first time and no node ID has been stored in the module, or after execut-
ing reset 1. Put the Z-Wave Controller into Inclusion mode 2. Press the tamper switch 3 times within 1.5 seconds to put the unit into inclusion mode 1. Put the Z-Wave Controller into Exclusion mode 2. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode 1. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode 2. Within 1 second of step 1, press the tamper switch again and hold until LED is off (about 5 seconds) 3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes LED indication 2-second ON, 2-second OFF for 2 minutes 2-second ON, 2-second OFF for 2 minutes Wakeup Command Class After it has been included into a Z-Wave network, the sensor will go to sleep but will send a Wakeup Notification Command periodically at preset interval to the controller. The Motion sensor will stay awake for at least 10 seconds and then go back to sleep to conserve battery life. The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class based on the range values below:
Factory Reset
(This procedure should only be used when the controller is inoperable) Minimum Wake Up Interval 600s (10 minutes) Maximum Wake Up Interval 86400s (1 day) Default Wake Up Interval 14400s (4 hours) Wake Up Interval Step Seconds 600s (10 minutes) Z-Waves Configuration Parameters The following information is for someone that has some experience in setting up a Z-Wave system or someone that has computer software running a Z-Wave controller. Please get familiar with software of Z-Wave controller before getting started. To save power for the battery, the motion sensor is normally in sleep mode. In order to wake the device up, press the tamper switch once. This will keep the device awake for 30 seconds indicated by the LED blinking every second. During this time, the user can change configuration parameters from the controller software. If more time is needed, continue pressing the tamper switch every 30 seconds.
* Failed or successful results in including/excluding the ID can be viewed on the Z-Wave Controller. Note: If you are connecting this unit to a Z-wave Controller that utilizes the S2 security protocol, you may be asked to enter a 5 digit Device Specific Key (DSK) that is unique to each unit by your controller. This can be found in one of two places:
on the QR code label on the back of the unit on the insert card inside the packaging www.eaton.com www.eaton.com/wiringdevices EIS-0246-EFS (REV. B)
"FOR REFERENCE ONLY"The table below lists typical problems encountered:
Symptoms Cannot carry out inclusion and association Cannot control the connected modules The sensor is not working Possible Cause 1. Run out of battery power 2. Reverse battery polarity 3. Sensor is out of order 1. Run out of battery power 2. Sensor is out of order 1. Run out of battery power 2. Check if the mounting location is proper 3. Check if the sensor is mounted above a radiator or heater 4. Sensor is out of order Solution 1. Replace a new battery 2. Refit the battery with correct polarity 3. Ensure the sensor is working properly 1. Replace a new battery 2. Ensure the sensor is working properly 1. Replace a new battery 2. Reposition its mounting location 3. Remove the source of interference or reposition its mounting location 4. Ensure the sensor is working properly Specifications Battery Battery Life RF Range CR123 3.0V 1700mAh Lithium Battery 2 year*
Up to 100 ft line of sight Warm Up Time About 2 minutes PIR Detection Coverage Up to 30 ft x 120 (at 71 ft mounting height & 25C) Operating Frequency 908.42 MHz FCC ID IC UH2-RF96PIRBMS 4706C-RF96PIRBMS
* Specifications are subject to change without notice * measured at 10 triggers per day FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1: This device may not cause harmful interference, and 2: This device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC CAUTION:
Any changes or modifications not expressly approved by Eaton Wiring Devices could void the users authority to operate the equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Industry Canadas licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1. Lappareil ne doit pas produire de brouillage;
2. Llutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. RADIATION EXPOSURE STATEMENT:
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with greater than 20cm between the radiator & your body. EATON WIRING DEVICES LIMITED 2 YEAR WARRANTY Eaton Wiring Devices warrants its switch to be free of defects in materials and workmanship in normal use and service for a period of two years from date of original purchase. THIS TWO (2) YEAR LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS, OR LIABILITIES, EXPRESSED OR IMPLIED (INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS IN DURATION IN EXCESS OF TWO YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE). NO AGENT, REPRESENTATIVE, OR EMPLOYEE OF EATON HAS AUTHORITY TO INCREASE OR ALTER THE OBLIGATIONS OF EATON UNDER THIS WARRANTY. To obtain warranty service for any properly installed Eaton switch that proves defective in normal use send the defective switch prepaid and insured to Quality Control Dept., Eaton Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269; in Canada: Eaton Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8. Eaton will repair or replace the defective unit, at its option. Eaton will not be responsible under this warranty if examination shows that the defective condition of the unit was caused by misuse, abuse, improper installation, alteration, improper maintenance or repair of damage in shipment to Eaton. EATON SHALL HAVE NO RESPONSIBILITY FOR INSTALLATION OF THE SWITCH, OR FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR ANY SPECIAL, INCIDENTAL, CONTINGENT, OR CONSEQUENTIAL DAMAGES OF ANY KIND, RESULTING FROM DEFECTS IN THE SWITCH OR FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT. THE EXCLUSIVE REMEDY FOR BREACH OF THE LIMITED WARRANTY CONTAINED HEREIN IS THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT AT EATONS OPTION. IMPLIED WARRANTIES (IF ANY) INCLUDING, BUT NOT LIMITED TO IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABIITY, ARE LIMITED IN DURATION TO A PERIOD ENDING TWO YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE. IN NO CASE SHALL EATONS LIABILITY UNDER ANY OTHER REMEDY PRESCRIBED BY LAW EXCEED THE PURCHASE PRICE. Some states do not allow the exclusion or limitation of incidental or consequential damages or allow disclaimers or modifications of or limitations on how long an implied warranty lasts, so the above limitations may not apply to you. Some Canadian provinces do not allow exclusion or variance of implied warranties so that some or all of the above limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state and province to province. Read enclosed instructions carefully. If you have any questions concerning use or care of this product, please write: Consumer Service Division, Eaton Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269. FRANAIS RF96PIRBMS DTECTEUR DE MOUVEMENT Z-WAVE Le dtecteur de mouvement est un appareil utilisant la technologie Z-WaveMC entirement compatible avec tout rseau Z-WaveMC. Il peut tre configur dans un rseau Z-Wave afin de communiquer directement avec dautres dispositifs terminaux, comme un interrupteur ou un gradateur, ou se connecter directement un contrleur Z-Wave tel quun concentrateur de domotique domestique dEaton ou tout autre contrleur certifi Z-Wave. Ce produit prend en charge le protocole de scuritS2, qui se sert de messages chiffrs Z-Wave Plus pour communiquer avec les autres produits scuriss de la gamme Z-Wave Plus. Pour profiter pleinement des fonctions de scurit de ce produit, il faut utiliser un contrleur scuris Z-Wave Plus. Le dtecteur de mouvement possde deux capteurs, un infrarouge passif et un de luminosit ambiant, ce qui amliore son efficacit pour les applications de scurit et de domotique domestique. En tant quappareil de scurit, le dtecteur transmet un signal au contrleur lorsquun mouvement pouvant dclencher une alarme ou une autre notification est dtect dans le champ de dtection. En tant quappareil domotique domestique, le dtecteur peut allumer ou teindre les lumires si quelquun entre ou sort dune pice ou dun primtre. Une minuterie peut tre rgle pour teindre les lumires automatiquement aprs une certaine priode de temps dinactivit. Le capteur de luminosit du systme donne accs plusieurs configurations qui peuvent varier selon le niveau de luminosit
(p.ex., jour ou nuit). Le dtecteur de mouvement est aliment par une pile au lithium CR123A de 3V dune dure de vie prvue de 2ans. Lorsque la pile est dcharge sous le seuil minimal, le dtecteur transmet un avertissement au contrleur. La pile doit tre alors remplace ds que possible. Aperu du produit Mise en place du rseau et des appareils Z-WaveMC Inclusion automatique Ce dtecteur prend en charge la fonction dinclusion automatique, cest--dire quil active automatiquement le mode dinclusion la premire mise en marche suivant toute rinitialisation dusine. 1. Utiliser un tournevis pour retirer le couvercle arrire. Couvercle arrire Vis de fixation 2. Mettre le contrleur Z-Wave en mode dinclusion. 3. Installer la pileCR123A de 3V dans le compartiment pile en respectant la polarit. Le tmoin DEL de lappareil devrait sallumer. Essai rapide Avant dinstaller lappareil, il est conseill de le configurer en mode dessai pour trouver la position idale du dtecteur. 1. Retirer le couvercle arrire avec un tournevis sil est fix lappareil. 2. Si le couvercle arrire est enlev, linterrupteur de scurit est allum et lappareil est en mode dessai. 3. Si un mouvement est dtect en mode dessai, le tmoin DEL du dtecteur clignotera une fois pour indiquer que lappareil fonctionne correctement. Il clignotera nouveau toutes les 5secondes si un mouvement est dtect. Il est galement possible de vrifier que lappareil est install un endroit optimal en mettant sa porte et son positionnement lessai (voir la section Choisir lemplacement). 4. Pour sortir du mode dessai, appuyer 10secondes sur linterrupteur de scurit ou remettre lecouvercle. 5. En mode normal, lorsque le capteur infrarouge passif est en fonction, le tmoin DEL rouge nest pas allum et le dlai entre les clignotements dpend du rglage de base. Essai Mise en marche Le dtecteur sera fonctionnel environ 2minutes aprs quune pile est installe. Le tmoin DEL derrire la lentille sallumera. Lorsque le tmoin rouge steint, la mise en marche est termine et ledtecteur est prt. Remarque: Cela ne nuira pas au processus dinclusion ou dexclusion. Remarque: Attendre 5secondes aprs avoir enlev la pile pour la remettre. Essai rapide Avant dinstaller lappareil, il est conseill de le configurer en mode dessai pour trouver la position idale du dtecteur. 1. Retirer le couvercle arrire avec un tournevis sil est fix lappareil. 2. Si le couvercle arrire est enlev, linterrupteur de scurit est allum et lappareil est en mode dessai. 3. Si un mouvement est dtect en mode dessai, le tmoin DEL du dtecteur clignotera une fois pour indiquer que lappareil fonctionne correctement. Il clignotera nouveau toutes les 5secondes si un mouvement est dtect. Il est galement possible de vrifier que lappareil est install un endroit optimal en mettant sa porte et son positionnement lessai (voir la section Choisir lemplacement). 4. Pour sortir du mode dessai, appuyer 10secondes sur linterrupteur de scurit ou remettre lecouvercle. 5. En mode normal, lorsque le capteur infrarouge passif est en fonction, le tmoin DEL rouge nest pas allum et le dlai entre les clignotements dpend du rglage de base. Installation du dtecteur Choisir lemplacement Le dtecteur est conu pour tre install uniquement lintrieur et dans un endroit sec. Il est conseill dinstaller le dtecteur dans le coin dune pice une hauteur entre 5,9pi et 6,6pi. Cette hauteur donne au dtecteur une porte de dtection de 30pi et un champ de dtection de 120 en cinquime position (voir les figures1 et 2). La carte de circuit imprim dans le dtecteur peut tre rgle selon cinq diffrentes positions pour ajuster la porte de dtection. Latroisime position diminue la porte denviron 20pi. En premire position, la porte est denviron 10pi. La position recommande est la position 5. La position doit tre rgle en fonctionde la porte dsire. 30 pi 20 pi 10 pi Figure1 6,6pi Position de la carte de circuit imprim 1 3 5 Porte 10pi (3 m) 20pi (6 m) 30pi(9 m) Figure2 La position doit tre rgle en suivant les directives ci-dessous pour que lappareil fonctionne correctement:
1. Ne pas installer le dtecteur devant une fentre ou un endroit o il serait directement expos aux rayons du soleil. 2. Ne pas installer le dtecteur prs des conduits daration. 3. Ne pas installer le dtecteur directement au-dessus dune source de chaleur comme un foyer, un radiateur ou une chaudire. 4. Ne pas installer le dtecteur un endroit o il serait sujet des vibrations excessives. 5. Si possible, installer le dtecteur dans le coin dune pice afin que le champ de dtection soit travers par une personne qui entrerait dans la pice. Les mouvements qui traversent le champ de dtection de lappareil sont mieux dtects par les capteurs infrarouges passifs que ceux qui sont orients directement vers lappareil (FIGURE3). 4. Le processus dinclusion devrait se terminer ds que le tmoin DEL cesse de clignoter. 5. Ne pas rinstaller le couvercle avant deffectuer les essais dcrits la section suivante. Remarque: Si linclusion automatique choue, consulter la section de dpannage qui se rapporte linclusion manuelle. Essai Mise en marche Le dtecteur sera fonctionnel environ 2minutes aprs quune pile est installe. Le tmoin DEL derrire la lentille sallumera. Lorsque le tmoin rouge steint, la mise en marche est termine et ledtecteur est prt. Remarque: Cela ne nuira pas au processus dinclusion ou dexclusion. Remarque: Attendre 5secondes aprs avoir enlev la pile pour la remettre. Moins sensible Figure3 6. Vrifier que la position du capteur infrarouge passif est porte du systme (consulter le guide dutilisation et dinstallation du systme). Plus sensible Good Sensitivity Installation Avant dinstaller lappareil, vrifier que la carte de circuit imprim est dans la position correspondant la porte de dtection dsire. Pour ajuster la porte, il suffit de dplacer la carte de circuit imprim vers le haut ou le bas en sassurant que les pattes de positionnement sont alignes avec le numro indiqu sur la carte qui correspond la position souhaite. Le dtecteur de mouvement peut tre install laide des vis ou du ruban adhsif double-face fournis. Installation avec le ruban adhsif double-face:
1. Retirer lune des bandes de protection du ruban pour le fixer larrire de lappareil. Pour une installation dans un coin, couper le ruban en deux et le placer sur les cts en angle pour installer correctement lappareil. 2. Retirer lautre bande de protection et installer lappareil lemplacement dsir. Appuyer jusqu ce que lappareil soit bien fix. Installation avec les vis:
1. Percer soigneusement les trous de montage requis dans le couvercle arrire laide dune mche de 3mm, selon le type dinstallation (dans un coin ou plat au mur). Remarque: Utiliser la position n1 des trous de montage pour une installation dans un coin et la position n2 pour une installation plat au mur (voir les FIGURES4a et 4b). Position n2 des trous de montage Position n1 des trous de montage Installation en coin Figure4a Figure4b 2. En utilisant le couvercle arrire comme modle, marquer la position des trous de montage au mur. 3. Fixer le couvercle arrire au mur laide des deux vis n4 de 18mm et des deux ancrages au mur de 25mm (un trou de 5mm sera ncessaire pour la pose des ancrages). Ne pas trop serrer les vis de fixation, car cela pourrait dformer ou endommager le couvercle. 4. Poser le dtecteur sur le couvercle arrire en veillant y insrer les fixations suprieures. Pousser sur la partie infrieure du dtecteur jusqu ce quil soit bien en place et visser la vis de fixation dans la partie infrieure du dtecteur pour le fixer solidement. Ne pas trop serrer les vis de fixation, car cela pourrait endommager le botier. Une fois lappareil fix et install dans un rseau Z-Wave, sassurer que les mouvements sont bien dtects et que le contrleur et les dispositifs connexes sont correctement activs. Programmation Groupe Z-Wave Le dtecteur prend en charge lun de ces deux groupes dassociation Z-Wave:
Groupe1: association avec 1nud du contrleur. Groupe2: association avec 4nuds (c.--d. avec des dispositifs terminaux, comme des interrupteurs ou des gradateurs). Cela permet au dtecteur de transfrer des commandes directement aux dispositifs terminaux sans avoir passer par le contrleur. Commandes du groupe1:
Lorsquelle est mise sous tension et quelle fait dj partie dun rseau Z-Wave, lunit envoie un rapport de notification au nud du groupe1. Lorsquelle dtecte un mouvement, lunit envoie un rapport de notification aux nuds du groupe1. Lorsque le mouvement cesse, un autre rapport de notification est envoy au groupe1. Lorsque ltat du dtecteur change, lunit vrifie ltat de la pile en mme temps. Si le niveau de la pile est faible, lunit envoie un rapport de pile aux nuds du groupe1. Lorsquune rinitialisation dusine est effectue, lunit envoie une notification de rinitialisation locale au nud du groupe1. Commandes du groupe2:
Lorsque le dtecteur est activ, lunit envoie une commande BASIC_SET contenant une valeur aux nuds du groupe2. Groupe Tableau dinformation sur le groupe dassociation (AGI) Classe de commandes et commandes (liste) Noctets Rapport de pile, rapport de notification de rinitialisation locale du dispositif Gnral Profil 1 2 Contrle Configuration de base Nom du groupe Cble de scurit Commande decapteur infrarouge passif Notification vnement Appareil mis sous tension pour la premire fois Dclenchement du capteur infrarouge passif activ Dclenchement du capteur infrarouge passif dsactiv Interrupteur de scurit enfonc pendant plus de 10secondes Interrupteur de scurit enfonc pendant plus de 10secondes, puis relch Pile Rapport de pile (valeur) 20 100 0xFF Type 0x08 0x07 0x07 0x07 0x07 vnement Dure des paramtres dvnement Paramtres dvnement 0x01 0x08 0x00 0x00 0x03 0x00 0x00 0x01 0x01 0x01 0x08 0x03 Description Niveau de charge de la pile (%) Pile faible www.eaton.com www.eaton.com/wiringdevices EIS-0246-EFS (REV. B)
"FOR REFERENCE ONLY"Classe de commande de sortie de veille Une fois inclus dans un rseau Z-Wave, le dtecteur passera en mode veille, mais enverra une commande de notification de sortie de veille au contrleur des intervalles prdfinis. Le dtecteur demouvement restera activ pendant au moins 10secondes, aprs quoi il retournera en mode veille afin de prserver la dure de vie de la pile. Lintervalle entre chaque commande de notification de sortie de veille peut tre configur dans la classe de commande de sortie de veille (COMMAND_CLASS_WAKE_UP_V2) selon les valeurs dintervalle ci-dessous:
Intervalle de sortie de veille minimal 600s (10minutes) Intervalle de sortie de veille maximal 86400s (1jour) Intervalle de sortie de veille par dfaut 14400s (4heures) Intervalle de sortie de veille par incrments 600s (10minutes) Paramtres de configuration du dtecteur Z-Wave Les renseignements suivants sadressent aux personnes ayant une certaine exprience avec la configuration de systmes Z-Wave ou celles ayant un logiciel excutant un contrleur Z-Wave. Il est recommand de se familiariser avec un logiciel de contrleur Z-Wave avant de commencer. Afin de prserver la dure de vie de la pile, le dtecteur de mouvement est habituellement en mode veille. Pour faire sortir lappareil du mode veille, appuyer une fois sur linterrupteur de scurit. Cela activera lappareil pendant 30secondes et le tmoin DEL clignotera chaque seconde. Pendant cette priode, lutilisateur peut modifier les paramtres de configuration depuis le logiciel du contrleur. Si le dlai nest pas suffisant, continuer dappuyer sur linterrupteur de scurit toutes les 30secondes. 1. Niveau de configuration de base Le niveau de configuration de base dtermine la valeur qui sera envoye par la commande de configuration de base pour les appareils associs au groupe2. Pour un appareil interrupteur bipolaire
(p.ex., une prise ou un module dappareil), il sagira dune simple commande dactivation. Pour un appareil interrupteur multipolaire (p.ex., un gradateur), il sagira du niveau dfini par ce paramtre. Exemple:
1 99: Activ (appareil interrupteur bipolaire) Niveau de gradation (interrupteur multipolaire) Fonction Numro de paramtre Taille Niveau de configuration de base 1 1 Plage 1 99 Par dfaut 99 2. Niveau de sensibilit (capteur infrarouge passif seulement) Afin dassurer lefficacit optimale du dtecteur, il est recommand de le mettre lessai en effectuant des mouvements aux extrmits les plus loignes du champ de dtection lors de la premire utilisation. Si les mouvements ne sont pas systmatiquement dtects, il suffit dajuster le niveau de sensibilit laide du paramtre de configuration n3. Ce paramtre peut tre configur selon des niveaux de sensibilit allant de 1 10, o 1 correspond un niveau de sensibilit faible et 10, un niveau de sensibilit lev. Fonction Numro de paramtre Niveau de sensibilit 3 Taille 1 Plage 1 10 Par dfaut 6 3. Configuration de lintervalle de redclenchement (capteur infrarouge passif seulement) La configuration de lintervalle de redclenchement permet de dfinir la priode de temps entre le dclenchement dun signal indiquant quun mouvement a t dtect et le redclenchement dun tel signal. Pendant cet intervalle, le dtecteur ne signalera aucun mouvement, mme si dautres mouvements sont dtects. Lintervalle peut tre rgl de 5 3600secondes. Fonction Intervalle de redclenchement Numro de paramtre 4 Taille 2 Plage 5 3600s Par dfaut 180 Dclench Mouvement dtect 180secondes Mouvement dtect
(aucune rponse)
(no response) Dclench d Mouvement dtect 4. Niveau dclairement (lux) Lutilisateur peut dfinir un niveau dclairement en pourcentage qui dtermine quel moment le capteur de luminosit sera activ. Si le niveau dclairement de la pice tombe en dessous de ce pourcentage et quun mouvement est dtect, le dtecteur transmettra une commande dactivation Z-Wave au contrleur. Le pourcentage peut tre rgl de 1% 100%. Fonction Numro de paramtre Niveau dclairement (lux) 5 Taille 1 Plage 1 100%
Par dfaut 20 5. Dure dallumage/extinction La fonction de dure dallumage/extinction est utile pour les dtecteurs connects un module ou un appareil dclairage. La dure indique la priode pendant laquelle le module/appareil dclairage demeurera allum. Par exemple, un module de lampe steint 100secondes aprs avoir t allum. Ce paramtre peut tre configur selon des dures allant de 5 3600secondes. Fonction Numro de paramtre Dure dallumage/extinction 6 Taille 2 Plage 5 3600s Par dfaut 15 Dtecteur dclench La lumire sallume 15secondes La lumire steint Mouvement dtect Guides de dpannage Le tableau ci-dessous numre les diverses tapes lies lajout ou au retrait de lunit du rseau Z-Wave. Action/tat Aucun nom de nud Description Le contrleur Z-Wave nattribue pas de nom de nud lunit. Tmoin DEL Allum pendant 2s, teint pendant 2s, et ce, pendant 2minutes Inclusion automatique Inclusion manuelle Exclusion Rinitialisation dusine
(Cette procdure ne doit tre utilise que lorsque le contrleur est inutilisable.) Lappareil est mis sous tension pour la premire fois et aucun nom de nud na t enregistr dans le module, ou il est mis sous tension aprs la rinitialisation. 1. Mettre le contrleur Z-Wave en mode dinclusion. 2. Appuyer sur linterrupteur de scurit trois (3) fois en 1,5seconde pour mettre le module en mode dinclusion. 1. Mettre le contrleur Z-Wave en mode dexclusion. 2. Appuyer sur linterrupteur de scurit trois fois en 1,5sec-
onde pour mettre le module en mode dexclusion. 1. Appuyer sur linterrupteur de scurit trois fois en 1,5sec-
onde pour mettre le module en mode dexclusion. 2. Dans la seconde qui suit ltape1, appuyer et maintenir enfonc linterrupteur de scurit jusqu ce que le tmoin DEL steigne (environ 5secondes). 3. Le nom du nud est exclu. Lappareil retourne son tat par dfaut et sera en mode dinclusion automatique pendant 4minutes. Allum pendant 2s, teint pendant 2s, et ce, pendant 2minutes
*La russite ou lchec de linclusion/exclusion du nom est affich sur le contrleur Z-Wave. Remarque: En cas de branchement de cette unit un contrleur Z-Wave qui se sert du protocole de scuritS2, lappareil peut exiger linscription dune cl prcise (DSK) de 5chiffres, rserve par votre contrleur chaque unit. Elle se trouve lun de ces deux emplacements:
sur ltiquette du codeQR, derrire lunit;
sur la fiche insre dans lemballage. Le tableau ci-dessous prsente les problmes habituellement rencontrs:
Solution Problmes 1. Remplacer la pile. Impossible dexcuter 2. Replacer la pile selon la bonne polarit. linclusion et 3. Sassurer que le dtecteur fonctionne bien. lassociation 1. Remplacer la pile. Impossible de contrler 2. Sassurer que le dtecteur fonctionne bien. les modules connects 1. Remplacer la pile. Le dtecteur ne 2. Rinstaller le dtecteur un autre endroit. fonctionne pas 3. Retirer la source dinterfrence ou rinstaller le dtecteur un autre endroit. 4. Sassurer que le dtecteur fonctionne bien. Cause possible 1. La pile est plat. 2. La polarit de la pile est inverse. 3. Le dtecteur est dfectueux. 1. La pile est plat. 2. Le dtecteur est dfectueux. 1. La pile est plat. 2. Le dtecteur est install dans un endroit inadquat. 3. Le dtecteur est install au-dessus dun radiateur ou dun appareil de chauffage. 4. Le dtecteur est dfectueux. Spcifications Pile Pile au lithiumCR123A de 3V et 1700mAh Dure de vie de la pile 2an*
RF Porte Jusqu 100pi en visibilit directe Priode dinitialisation Champ de dtection du capteur infrarouge passif Frquence de fonctionnement ID DE LA FCC Environ 2minutes Jusqu 30pix 120 ( une hauteur de montage de 1,8m et une temprature de 25C) 908,42MHz UH2-RF96PIRBMS IC 4706C-RF96PIRBMS
*Les spcifications sont indiques sous rserve de modifications. *Elles sont mesures selon une frquence de 10dclenchements par jour. ESPAOL RF96PIRBMS - SENSOR DE MOVIMIENTO Z-WAVE PLUS 2 of 2 El sensor de movimiento es un dispositivo habilitado para Z-WaveTM totalmente compatible con cualquier red habilitada para Z-WaveTM . El dispositivo puede configurarse en una red Z-Wave para comunicarse directamente con otros dispositivos finales como interruptores o reguladores, o para conectarse con un controlador Z-Wave tal como el centro de automatizacin residencial de Eaton uotros controladores Z-Wave certificados. Este producto es compatible con el protocolo de seguridad S2 que usa mensajes encriptados de Z-Wave Plus para comunicarse con otros productos Z-Wave Plus con seguridad habilitada. A fin de aprovechar completamente las funciones de seguridad de este producto, debe usarse un controlador Z-Wave Plus con seguridad habilitada. El sensor de movimiento est diseado con dos sensores de deteccin, sensor infrarrojo pasivo (PIR, por sus siglas en ingls) y sensor de luz ambiental, para optimizar su rendimiento para aplicaciones de seguridad y automatizacin en el hogar. En el caso de las aplicaciones de seguridad, el sensor transmitir una seal a un controlador cuando se detecte algn movimiento dentro del campo visual del dispositivo, lo cual podra activar una alarma o algn otro aviso. En el caso de la automatizacin en el hogar, el sensor puede usarse para encender o apagar luces cuando alguien ingresa a o se retira de una habitacin o un rea. Esto incluye un temporizador con lmite de tiempo que puede apagar automticamente las luces cuando ya no detecta movimiento, despus de una cantidad de tiempo configurable. El sensor de luz permite que el sistema se configure para implementar distintas acciones basndose en el nivel de luz ambiental (como el da vs. noche). El sensor de movimiento usa una batera de litio CR123 3,0 V que, bajo condiciones normales, tendr un duracin de hasta 2 aos. Cuando el nivel de la batera desciende a un nivel inaceptable, el sensor emitir un mensaje de batera baja al controlador Z-Wave. Cuando esto ocurre, se debe reemplazar las bateras lo antes posible. Descripcin general del producto Prueba rpida Antes de montar el dispositivo, se recomienda que este se ubique en modo de prueba para encontrar la posicin ptima del sensor. 1. Si la cubierta posterior est adherida, retrela usando un destornillador. 2. Con la cubierta posterior separada, el interruptor de seguridad estar en posicin abierta y la unidad entrar en modo de prueba. 3. Si se detecta movimiento durante el modo de prueba, el LED del sensor se iluminar una vez, lo cual indica que la unidad est funcionando correctamente, y se reactivar aproximadamente cada 5 segundos si se detecta movimiento. Durante este modo, tambin puede probar el rango y el posicionamiento para garantizar que est colocado en un lugar ptimo (vea la seccin de Eleccin de ubicacin). 4. Para salir del modo de prueba, simplemente presione el interruptor de seguridad durante ms de 10 segundos o simplemente reubique la cubierta posterior que causa que el interruptor de seguridad est pulsado. 5. Durante el modo normal, cuando el PIR est activado, el LED rojo no se iluminar y el tiempo de reactivacin se basa en el valor de configuracin. Montaje del sensor Eleccin de ubicacin El sensor PIR es idneo para el montaje solo en interiores secos. La posicin recomendada para un sensor PIR es la esquina de una habitacin; debe montarse a una altura entre 5,9 pies y 6,6 pies. A esta altura, el sensor tendr un rango mximo de hasta 30pies con un campo visual de 120 , sujeto a la posicin para el sensor que est fijado en la posicin5. (vea las FIGURAS 1 y 2) La posicin de la placa de circuito impreso (PCB, por sus siglas en ingls)que se encuentra dentro del sensor puede fijarse en 5 posiciones distintas para ajustar el rango del sensor. Fijar la PCB en posicin 3 reducir el rango a aproximadamente 20 pies, con la posicin 1 proporcionando un rango de aproximadamente 10 pies. La fijacin de posicin recomendada para el sensor es la posicin 5. La posicin debe estar fijada segn el rango deseado del usuario. Instalacin y adicin a red Z-WaveTM Inclusin automtica El sensor es compatible con la funcin de inclusin automtica donde entrar automticamente en modo Inclusin cuando se encienda por primera vez despus de un reinicio de fbrica. 1. Use un destornillador para separar la cubierta posterior. Cubierta posterior Tornillo de fijacin 2. Ponga un controlador Z-Wave en modo Inclusin. 3. Inserte la batera 1 CR123 3V en el compartimento para batera con la polaridad correcta. El LED del dispositivo deber encenderse. 30 pies 20 pies 10 pies Figura 1 6.6 pies Posicin de la PCB 1 3 5 Rango 10 pies (3 m) 20 pies(6 m) 30 pies(9 m) Figura 2 Al determinar la posicin de montaje para el sensor, deben considerarse los siguientes puntos para garantizar una operacin sin problemas:
1. No ubique el sensor mirando hacia la ventana ni donde est expuesto a o mirando hacia la luz solar directa. 2. No ubique el sensor cerca de rejillas de ventilacin. 3. No ubique el sensor directamente sobre una fuente de calor (por ejemplo, fuego, un radiador, un hervidor, etc.). 4. No ubique el detector en una posicin en la que est sujeto a vibracin excesiva. 5. Siempre que sea posible, monte el sensor en la esquina de la habitacin para que el camino lgico de una persona interfiera el patrn de deteccin del ventilador. Los sensores PIR responden ms eficazmente al movimiento a lo largo del dispositivo que al movimiento directamente hacia l.
(FIGURA 3). Menos sensible Figura 3 Good Sensitivity Ms sensible 6. Asegrese de que la posicin seleccionada para el sensor PIR est dentro del rango efectivo del sistema, (consulte el Manual de Instalacin del Sistema y Funcionamiento). www.eaton.com www.eaton.com/wiringdevices EIS-0246-EFS (REV. B) Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
1. Lappareil ne doit pas produire de brouillage;
2. Llutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. DCLARATION DEXPOSITION AUX RADIATIONS:
Cet quipement est conforme aux limites dexposition aux rayonnements ISED tablies pour un environnement non contrl. Cet quipement doit tre install et utilis plus de 20 cm entre le radiateur et votre corps. GARANTIE LIMITE DE DEUX ANS DEATONWIRINGDEVICES EatonWiringDevices garantit que son interrupteur est exempt de dfauts de fabrication et de matriaux dans des conditions dutilisation et de service normales pour une priode de deux ans compter de la date dachat initiale. CETTE GARANTIE LIMITE DE DEUX ANS REMPLACE TOUTE AUTRE GARANTIE, OBLIGATION OU RESPONSABILIT, QUELLE SOIT EXPLICITE OU IMPLICITE (Y COMPRIS TOUTE GARANTIE IMPLICITE DE QUALIT MARCHANDE ET DADAPTATION UN USAGE PARTICULIER QUI DURE PLUS DE DEUX ANS COMPTER DE LA DATE DACHAT INITIALE). AUCUN AGENT, REPRSENTANT OU EMPLOY DEATON NA LE POUVOIR DAUGMENTER OU DE MODIFIER LES OBLIGATIONS DEATON EN VERTU DE CETTE GARANTIE. Pour obtenir un service de garantie pour tout interrupteur Eaton correctement install qui savre dfectueux dans des conditions dutilisation normales, faire parvenir linterrupteur en question en envoi prpay et assur ladresse suivante: Quality Control Dept., EatonWiringDevices, 203CooperCircle, PeachtreeCity, GA30269; ou au Canada: EatonWiringDevices, 5925McLaughlinRoad, Mississauga (Ontario) L5R1B8. Eaton rparera ou remplacera lunit dfectueuse, sa discrtion. Eaton ne pourra tre tenu responsable en vertu de la prsente garantie si lexamen prouve que le problme a t caus par une mauvaise utilisation, une utilisation abusive, une installation inadquate, une altration, un mauvais entretien ou une rparation inapproprie avant lenvoi Eaton. EATON DCLINE TOUTE RESPONSABILIT QUANT LINSTALLATION DE LINTERRUPTEUR ET TOUTE BLESSURE, TOUT DOMMAGE MATRIEL OU TOUT DOMMAGE PARTICULIER, CONSCUTIF OU INDIRECT DE TOUTE SORTE DCOULANT DES DFAUTS DE LINTERRUPTEUR OU DE LA VIOLATION DUNE GARANTIE EXPLICITE OU IMPLICITE DU PRODUIT. LE SEUL RECOURS EN CAS DE VIOLATION DE LA GARANTIE LIMITE DCRITE DANS LES PRSENTES EST LA RPARATION OU LE REMPLACEMENT DU PRODUIT DFECTUEUX, LA DISCRTION DEATON. LES GARANTIES IMPLICITES (LE CAS CHANT) IMPLIQUENT, SANS TOUTEFOIS SY LIMITER, LES GARANTIES IMPLICITES DE QUALIT MARCHANDE ET DADAPTATION UN USAGE PARTICULIER, ET DURENT DEUX ANS COMPTER DE LA DATE DACHAT INITIALE. EN AUCUN CAS LA RESPONSABILIT DEATON NE PEUT DPASSER LE PRIX DACHAT EN VERTU DE TOUT AUTRE RECOURS AUTORIS PAR LA LOI. Les limitations ci-dessus peuvent ne pas sappliquer votre cas, car certains tats ne permettent pas lexclusion ou la limitation de responsabilit en cas de dommage particulier ou indirect ou autorisent lexonration de responsabilit ou encore la modification ou la limitation de la dure dune garantie implicite. Certaines provinces canadiennes nautorisent pas lexclusion ou les carts de garanties implicites, certaines des limitations ci-dessus peuvent donc ne pas sappliquer votre cas. La prsente garantie vous donne des droits lgaux prcis, et dautres droits peuvent vous tre accords dun tat lautre ou dune province lautre. Lire attentivement les instructions. En cas de questions concernant lutilisation ou lentretien de ce produit, crire : ConsumerServiceDivision, EatonWiringDevices, 203Cooper Circle, PeachtreeCity, GA30269. 4. El proceso de inclusin se habr completado cuando el LED deje de parpadear. 5. No reajuste la cubierta posterior an y proceda a la seccin de Pruebas antes de realizar el montaje. Nota: Si la inclusin automtica falla, consulte la seccin de Resolucin de Problemas que se refiere a la inclusin manual. Prueba Calentamiento Tardar aproximadamente 2 minutos para que el sensor se caliente, despus de la insercin de la batera. Durante este tiempo, el LED que se encuentra detrs del cristal se encender. Cuando el LED rojo se apaga, significa que el procedimiento de calentamiento se ha completado y que el sensor est listo para deteccin. Nota: Esto no afectar el proceso de inclusin/exclusin. Nota: Despus de retirar las bateras, espere 5 segundos para reequipar las bateras.
"FOR REFERENCE ONLY"Clase de comando de reactivacin Despus de que este se haya incluido en una red Z-Wave, el sensor se desactivar pero enviar peridicamente un comando de aviso de reactivacin al controlador en el intervalo preconfigurado. El sensor de movimiento se mantendr activo durante al menos 10 segundos y luego volver a desactivarse para conservar la duracin de la batera. El intervalo de tiempo entre los comandos de aviso de reactivacin pueden configurarse en la clase de comando de reactivacin, segn los valores de rango que se indican a continuacin:
Guas de resolucin de problemas La siguiente tabla menciona los diversos pasos que implica aadir o eliminar la unidad de la red Z-Wave. Accin/estado Sin identificacin de nodo Descripcin El controlador Z-Wave no asigna una identificacin de nodo a la unidad Indicacin del LED 2 segundos de encendido, 2 segundos de apagado por 2 minutos La siguiente tabla menciona los problemas tpicos encontrados:
Sntomas No puede llevarse a cabo inclusin y asociacin Posible causa 1. Se qued sin batera 2. Polaridad revertida de la batera 3. El sensor est fuera de servicio Solucin 1. Reemplace por una nueva batera 2. Reajuste la batera con la polaridad correcta 3. Asegrese de que el sensor est funcionando correctamente 1. Reemplace por una nueva batera 2. Asegrese de que el sensor est funcionando correctamente Inclusin automtica Inclusin manual Exclusin Reinicio de fbrica
(Este procedimiento solo debe usarse cuando el controlador est inoperable) Se aplica energa por primera vez y no se ha almacenado identificacin de nodo en el mdulo, odespus de ejecutar el reinicio. 1. Ponga el controlador Z-Wave en modo Inclusin. 2. Presione el interruptor de seguridad 3 veces dentro de 1,5 segundos para poner la unidad en modo de inclusin. 1. Ponga el controlador Z-Wave en modo Exclusin. 2. Presione el interruptor de seguridad 3 veces dentro de 1,5 segundos para poner la unidad en modo de exclusin. 1. Presione el interruptor de seguridad 3 veces dentro de 1,5 segundos para poner la unidad en modo de exclusin. 2. Dentro de 1 segundo del paso 1, presione el interruptor de seguridad nuevamente y mantngalo presionado hasta que el LED se apague (aproximadamente 5segundos) 3. La identificacin del nodo es excluida. El dispositivo vuelve al estado de configuracin predeterminada de fbrica y estar en modo de inclusin automtica durante 4 minutos.
* Si falla o tiene xito al incluir/excluir la identificacin, puede verlo en el controlador del Z-Wave. Nota: Si est conectando esta unidad a un controlador Z-Wave que utiliza el protocolo de seguridad S2, es posible que se le solicite que ingrese una Clave Especfica del Dispositivo (DSK, por sus siglas en ingls) de 5dgitos, que es nica para cada unidad por parte de su controlador. Esta puede encontrarse en uno de estos dos lugares:
En la etiqueta del cdigo QR en la parte posterior de la unidad En la tarjeta de insercin dentro del empaque No puede controlar los mdulos conectados 1. Se qued sin batera 2. El sensor est fuera de servicio El sensor no est funcionando 2 segundos de encendido, 2 segundos de apagado por 2 minutos Especificaciones 1. Se qued sin batera 2. Revise si la ubicacin del montaje es correcta 3. Revise si el sensor est montado sobre un radiador o calentador 4. El sensor est fuera de servicio 1. Reemplace por una nueva batera 2. Reubique su lugar de montaje 3. Retire la fuente de interferencia oreubique su lugar de montaje 4. Asegrese de que el sensor est funcionando correctamente Batera Batera de litio CR123 3,0 V 1700 mAh Vida til de la batera 2 ao*
RF Rango Lnea visual de hasta 100 pies Tiempo de calentamiento Aproximadamente 2 minutos Cobertura de deteccin de PIR Hasta 30 pies x 120 (a una altura de montaje de 1,8 m y 25 C) Frecuencia de operacin 908,42 MHz Identificacin FCC IC UH2-RF96PIRBMS 4706C-RF96PIRBMS
* Las especificaciones estn sujetas a cambio sin notificacin * medido en 10 disparadores por da GARANTA LIMITADA DE 2 AOS OTORGADA POR EATON WIRING DEVICES Eaton Wiring Devices garantiza que su interruptor est libre de defectos en lo referente a materiales y mano de obra bajo uso y servicio normales durante un periodo de dos aos a partir de la fecha de compra original. ESTA GARANTA LIMITADA DE DOS (2) AOS REEMPLAZA TODAS LAS DEMS GARANTAS, OBLIGACIONES O RESPONSABILIDADES, EXPRESAS O IMPLCITAS (INCLUYENDO TODA GARANTA IMPLCITA DE COMERCIABILIDAD O IDONEIDAD PARA UN PROPSITO DETERMINADO QUE, EN CUANTO A DURACIN, EXCEDA LOS DOS AOS A PARTIR DE LA FECHA DE LA COMPRA ORIGINAL DEL CLIENTE). NINGN AGENTE, REPRESENTANTE O EMPLEADO DE EATON TIENE LA AUTORIDAD PARA AUMENTAR O ALTERAR LAS OBLIGACIONES DE EATON BAJO ESTA GARANTA. A fin de obtener servicios de garanta para todo interruptor Eaton instalado correctamente que pruebe defectos en condiciones normales de uso, enve el interruptor defectuoso prepagado y asegurado al Departamento de Control de Calidad, Eaton Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269; en Canad: Eaton Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8. Eaton reparar o remplazar la unidad defectuosa, a su libre eleccin. Eaton no se responsabilizar, bajo la presente garanta, si la inspeccin indica que la condicin defectuosa de la unidad fue causada por uso inadecuado, abuso, instalacin inapropiada, alteracin, mantenimiento o reparacin inapropiados de daos en el envo a Eaton. EATON NO SER RESPONSABLE DE LA INSTALACIN DEL INTERRUPTOR, NI DE NINGUNA LESIN, DAO A LA PROPIEDAD, O TIPO DE DAO ESPECIAL, INCIDENTAL, CONTINGENTE O CONSECUENTE, QUE RESULTE DE LOS DEFECTOS EN EL INTERRUPTOR O POR INCUMPLIMIENTO DE ALGUNA GARANTA EXPRESA O IMPLCITA DE ESTE PRODUCTO. LA NICA SOLUCIN POR INCUMPLIMIENTO DE LA GARANTA LIMITADA CONTENIDA EN EL PRESENTE DOCUMENTO ES LA REPARACIN O EL REEMPLAZO DEL PRODUCTO DEFECTUOSO A LA LIBRE ELECCINDE EATON. INCLUYENDO LAS GARANTAS IMPLCITAS (SI LAS HUBIERA), PERO NO LIMITNDOSE A LAS GARANTAS IMPLCITAS DE IDONEIDAD PARA UN PROPSITO EN PARTICULAR Y COMERCIABILIDAD, ESTN LIMITADAS EN DURACIN A UN PERIODO QUE TERMINARA A LOS DOS AOS DE LA FECHA DE LA COMPRA ORIGINAL DEL CONSUMIDOR. EN NINGN CASO, LA RESPONSABILIDADDE EATON, BAJO CUALQUIER OTRA SOLUCIN PRESCRITA POR LEY, SUPERAR EL PRECIO DE COMPRA. Algunos estados no permiten la exclusin o limitacin de los daos incidentales o consecuentes ni permiten descargos de responsabilidad, modificaciones o limitaciones a la duracin de una garanta implcita, de modo que las limitaciones anteriores pueden no ser aplicables en su caso. Algunas provincias de Canad no permiten la exclusin o variacin de las garantas implcitas, por lo que es posible que algunas o todas las limitaciones anteriores no se apliquen en su caso. Esta garanta le otorga derechos legales especficos y tambin puede tener otros derechos que varan de un estado a otro y de una provincia a otra. Lea cuidadosamente las instrucciones incluidas. Si tiene alguna pregunta con respecto al uso o cuidado de este producto, escriba a: Divisin de Servicio al Cliente, Eaton Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269. Intervalo mnimo de reactivacin 600 s (10 minutos) Intervalo mximo de reactivacin 86 400 s (1 da) Intervalo de reactivacin predeterminado 14 400 s (4 horas) Segundos del paso del intervalo de reactivacin 600 s (10 minutos) Parmetros de configuracin de Z-Wave La siguiente informacin est destinada a personas que tienen cierta experiencia en la configuracin de un sistema Z-Wave o a personas que tienen un software informtico que ejecuta un controlador Z-Wave. Familiarcese con el software del controlador Z-Wave antes de empezar. Para ahorrar energa para la batera, el sensor de movimiento est normalmente en modo de suspensin. Para reactivar el dispositivo, presione el interruptor de seguridad una vez. Esto har que el dispositivo se mantenga activo durante 30 segundos, lo cual lo indica el LED que parpardea cada segundo. Durante este tiempo, el usuario puede cambiar los parmetros de configuracin desde el software del controlador. Sise necesita ms tiempo, contine presionando el interruptor de seguridad cada 30 segundos. 1. Nivel de configuracin bsica El nivel de configuracin bsica determina el valor que se enviar desde el comando de configuracin bsica para dispositivos asociados con el Grupo 2. En el caso de dispositivos con interruptor binario (por ejemplo, mdulo de aparato o receptculo), ser un comando de encendido simple. En el caso de dispositivos con interruptores de mltiples niveles (por ejemplo, un regulador), se configurar en el nivel fijado por este parmetro. Ejemplo:
1-99: ENCENDIDO (dispositivo con interruptor binario) Nivel del regulador (dispositivo con interruptor de mltiples niveles) Funcin Nmero de parmetro Tamao Nivel de configuracin bsica 1 1 Rango 1 ~ 99 Valor predeterminado 99 2. Nivel de sensibilidad (solo para sensor PIR) A fin de proporcionar la mayor eficiencia del sensor, se recomienda probar el sensor con movimientos desde el extremo ms alejado del rea de cobertura, la primera vez que lo use. Si los movimientos no pueden ser detectados consistentemente, simplemente ajuste el nivel de sensibilidad con el parmetro de configuracin #3. Este parmetro puede ser configurado con valores del 1 hasta el 10, donde 1 significa sensibilidad baja y 10 significa sensibilidad alta. Funcin Nmero de parmetro Tamao Nivel de sensibilidad 3 1 Rango 1 ~ 10 Valor predeterminado 6 3. Configuracin del intervalo de reactivacin (solo para sensor PIR) La configuracin del intervalo de reactivacin determina la cantidad de tiempo que transcurre hasta que el sensor reactiva una seal de que se ha detectado movimiento. Durante este tiempo, el sensor no informar movimiento pese a que se detecte movimiento. El intervalo de tiempo puede ser configurado entre 5 segundos y 3600 segundos. Funcin Nmero de parmetro Tamao Rango Valor predeterminado Intervalo de reactivacin 4 2 5~3600 (segundos) 180 Activado Detect un movimiento 4. Nivel de lux 180 segundos Detect un movimiento
(no hay respuesta)
(no response) Activado d Detect un movimiento El usuario puede configurar un porcentaje de nivel de lux que determina cundo se activar el sensor de luz. Si el nivel de lux de la iluminacin ambiental desciende por debajo de este porcentaje, yse detecta movimiento, el sensor emitir un comando de encendido de Z-Wave al controlador. El porcentaje puede configurarse entre 1% y 100%. Instalacin Antes del montaje, asegrese de que la posicin de la PCB del sensor sea la correcta para brindar el rango de deteccin deseado. Para ajustar el rango, simplemente deslice la PCB hacia arriba o hacia abajo asegurndose de que las patas de posicin estn alineadas con el nmero de posicin que se marca en la placa. El sensor de movimiento puede ser montado usando ya sea la cinta adhesiva de doble cara o los tornillos. Para la instalacin usando la cinta adhesiva de doble cara:
1. Retire un lado de la cubierta adhesiva y adhirala adecuadamente a la parte posterior del dispositivo. En el caso del montaje en esquina, se recomienda cortar la cinta adhesiva en dos pedazos y colocarlos en cada lado angulado para garantizar un mejor ajuste. 2. Retire el otro lado de la cubierta adhesiva, coloque el dispositivo en su posicin deseada y ejerza presin hasta que el dispositivo est seguro. Para la instalacin usando tornillos:
1. Taladre cuidadosamente los orificios de montaje requeridos en la cubierta posterior haciendo una perforacin de 3 mm dependiendo de si la unidad se est montando en una esquina o contra una pared plana. Nota: Use las posiciones de orificios del 1er montaje para la instalacin de montaje en esquina, y use las posiciones de orificios del 2do montaje para la instalacin en pared plana. (Vea la FIGURA 4a y 4b) Posiciones de orificios del 2do montaje Posiciones de orificios del 1er montaje Montaje de esquina Figura 4a Figura 4b 2. Usando la cubierta posterior como plantilla, marque las posiciones de los orificios de fijacin en la pared. 3. Fije la cubierta posterior a la pared usando los dos tornillos n. 4 de 18 mm y los anclajes de pared de 25 mm, (se necesitar un orificio de 5 mm para los anclajes de pared). No ajuste demasiado los tornillos de fijacin, ya que esto podra deformar o daar la cubierta. 4. Encaje el sensor en la cubierta posterior colocando los sujetadores del borde superior en la cubierta posterior. Presione el borde inferior del sensor en su lugar y vuelva a encajar el tornillo de fijacin en el borde inferior del sensor para asegurarlo en su lugar. No ajuste demasiado los tornillos de fijacin, ya que esto podra daar la carcasa. Una vez que el dispositivo est montado e instalado en una red Z-Wave, asegrese de que el movimiento sea detectado adecuadamente y de que los dispositivos asociados y/o el controlador estn activados correctamente. Programacin Grupo Z-Wave El sensor es compatible con cualquiera de los dos Grupos de Asociacin de Z-Wave:
Grupo 1: Asociacin con 1 nodo controlador. Grupo 2: Asociacin con 4 nodos (es decir, dispositivos finales como interruptores o reguladores). Esto permite que el sensor transfiera comandos directamente a dispositivos finales sin tener que pasar por el controlador. Comandos del Grupo 1:
Cuando la unidad se enciende y ya es parte de una red Z-Wave, esta enva un informe de aviso al nodo del Grupo 1. Cuando la unidad siente movimiento, enva un informe de aviso a los nodos del Grupo 1. Una vez que el movimiento se detiene, se enviar nuevamente un informe de aviso al Grupo 1. Cuando el estado del sensor cambia, la unidad revisa simultneamente el estado de su batera. Cuando el nivel de la batera de la unidad es bajo, la unidad emite un informe de batera a los nodos del Grupo 1. Al realizar el reinicio de fbrica, la unidad enviar el aviso a nivel local del reinicio del dispositivo al nodo del Grupo 1. Comandos del Grupo 2:
Cuando el sensor se activa, la unidad enva el comando BASIC_SET, que contiene un valor, a los nodos del Grupo 2. Tabla de Informacin del Grupo de Asociacin (AGI) Clase de comandos y bytes N de (lista de) comandos Informe de batera, aviso a nivel local del reinicio del dispositivo Configuracin bsica Nombre del grupo Sustento Control del PIR Evento 0x01 0x08 0x00 0x00 0x03 Longitud de los parmetros del evento Parmetros del evento 0x00 0x00 0x01 0x01 0x01 0x08 0x03 Grupo 1 2 Notificacin Evento Se aplica energa por primera vez Disparador del PIR ENCENDIDO Disparador del PIR APAGADO Interruptor de seguridad presionado ms de 10 segundos Interruptor de seguridad presionado ms de 10 segundos y soltado Batera Informe de batera (valor) 20 ~ 100 0xFF Perfil General Control Tipo 0x08 0x07 0x07 0x07 0x07 Descripcin Nivel de batera (%) Batera Baja Funcin Nivel de lux Nmero de parmetro Tamao 5 1 Rango 1 ~ 100%
Valor predeterminado 20 5. Duracin de encendido-apagado La funcin de configuracin de encendido-apagado ser til si el detector est conectado con un mdulo o iluminacin. La duracin determina cunto tiempo debe permanecer encendido el mdulo/la iluminacin. Por ejemplo, el Mdulo de Lmparas se apaga 100 segundos despus de haberse encendido. Este parmetro puede ser configurado con valores del 5 hasta el 3600, donde 5 significa un retraso de 5 segundos y 3600 significa un retraso de 3600 segundos. Funcin Nmero de parmetro Tamao Duracin de ENCENDIDO-
APAGADO La deteccin est activada 6 2 La luz se enciende 15 segundos Rango 5-3600
(segundos) Valor predeterminado 15 La luz se apaga Detect un movimiento www.eaton.com www.eaton.com/wiringdevices EIS-0246-EFS (REV. B)
"FOR REFERENCE ONLY"
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2019-03-07 | 908.42 ~ 908.42 | DXX - Part 15 Low Power Communication Device Transmitter | Change in identification of presently authorized equipment. Original FCC ID: FU5SP817 Grant Date: 11/17/2017 |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2019-03-07
|
||||
1 | Applicant's complete, legal business name |
Cooper Wiring Devices Inc
|
||||
1 | FCC Registration Number (FRN) |
0015363989
|
||||
1 | Physical Address |
203 Cooper Circle
|
||||
1 |
Peachtree City,, Georgia 30269
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
t******@us.bureauveritas.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
UH2
|
||||
1 | Equipment Product Code |
RF96PIRBMS
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
E******** G********
|
||||
1 | Telephone Number |
77063********
|
||||
1 | Fax Number |
77063********
|
||||
1 |
e******@eaton.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Z-WAVE PLUS MOTION SENSOR | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Change in identification of presently authorized equipment. Original FCC ID: FU5SP817 Grant Date: 11/17/2017 | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Bureau Veritas CPS(H.K.) Ltd., Taoyuan Branch
|
||||
1 | Name |
K******** L******
|
||||
1 | Telephone Number |
+886-******** Extension:
|
||||
1 | Fax Number |
+886-********
|
||||
1 |
k******@tw.bureauveritas.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 908.42000000 | 908.42000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC