Job: ELAN Manual Size: 150 x 150 mm folded 05/20/2014 -> final print pdf ELAN Quick Install Guide g1 6 pages each - Format: 150 x 300 mm ( Metric !! ) Final Version English ONLY ONE MANUAL !
Folding-Method:
g1 Quick Install Guide English 0 0 3 150 150 150 Folded size:
150 x 150 mm Open:
450 mm wide x 300 mm high No bleed 05/20/2014 FR -> 2nd update _9 Up Questions?
Juergen 707 - 778- 5826
P/N 9901340 Rev. B 05/2014 g1 Quick Install Guide English g1 Quick Install Guide English 9901340_ELAN_QuickGuide_g1_ENG_0523_PRINT.indd 2 5/23/14 5:36 PM g1 Rear Panel Connections Dimension: 7-3/16 W x 1-1/4 H x 5-1/8 D (half rack) (182mm W x 30mm H x 130mm D) POWER Powerbutton and power light SERIAL CONNECTIONS 1 bi-directional RS-232 TEST PORT For factory use ONLY IR OUTPUTS 3 discrete IR channels. Compatible with Xantech single and dual emitters AUDIO For future use ONLY SENSE INPUT CONNECTION 1 ELAN Sensor Input IR INPUT 1 powered Xantech Sensor compatible DC Power Connection 12v 1A USB CONNECTION see integration notes for compatible applications OSD HDMI on screen display ETHERNET CONNECTION Ethernet - 10/100/1000 Mbps PoE IEEE 802.3at, Type I 48 VDC, 350 mA RESET RESET FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help. Informations concernant lexposition aux frquences radio (RF):
La puissance de sortie mise par lappareil de sans l est infrieure la limite exposition aux frquences radio dIndustry Canada (IC). Utilisez lappareil de sans l de faon minimiser les contacts humains lors du fonctionnement normal. Ce priphrique a galement t valu et dmontr conforme aux limites dexposition aux RF dIC dans des conditions dexposition des appareils mobiles
(antennes sont suprieures 20 cm partir du corps dune personne). 9901340_ELAN_QuickGuide_g1_ENG_0523_PRINT.indd 3 g1 Quick Install Guide English Important Safety Instructions 1. Read, understand and follow ALL safety and installation instructions included in this manual. Failure to follow the included documentation may damage the product and will void manufacturers warranty. 2. Follow ALL installation guidelines included with the product. Installation of the product in high humidity environments, in close proximity to heat sources and /or non-recommended locations WILL impede, interfere and/or damage the intended operation of the product 3. Only use attachments and accessories which have been speci ed for use by the manufacturer. 4. The use of abrasive, liquid or solvent based cleaning uids WILL damage the product. Please refer and follow all Product Care instructions included with the product. 5. Product Servicing may ONLY be completed by authorized or certi ed service centers & personnel. For a complete list of product servicing options, please follow instructions included in the product documentation and /or contact original manufacturer for details. FCC and IC Information:
This Class B digital apparatus complies with Part 15 of the FCC rules and with Canadian ICES-003 and RSS-210. Cet appareil numrique de classe B est conforme aux normes canadiennes ICES-003 et RSS-210. Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer dinterfrence et (2) cet appareil doit accepter toute interfrence, notamment les interfrences qui peuvent affecter son fonctionnement. Warning:
Changes or modi cations to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC and IC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the exemption from the routine evaluation limits in section 2.5 of RSS 102. 1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters from user and bystanders. Operation is subject to the following two conditions:
1. This device may not cause interference and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Warning:
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102, and users can obtain Canadian information on RF exposure and compliance from the Canadian Representative Product Solutions Group at Tel: (519) 763-4538. 2014 Core Brands, LLC. All rights reserved.ELAN, g! and Panamax are registered trademarks ofCore Brands,LLC,aNortek company. P/N 9901340 Rev. B 05 /2014 5/23/14 5:36 PM To protect your equipment from power surges and momentary power interruptions we strongly suggest you utilize a battery-backed power supply (UPS) with this equipment. ELAN recommends Panamax UPS and power conditioning products for use with your new g1. Unpack the g1. Verify that you have all packaging contents. E LA N You should have received:
a. g1 b. 12vDC Power Supply c. Hand held g1 remote (P/N g1REM)) d. IR sensor (Xantech P/N DL95) e. 3ea IR emitter (Xantech P/N 282D) The g1 may be used as a standalone system controller with or as an Extender to any gSC controller or a HC controller running g!6.6 or greater. Please check the ELAN Training Guide for g1 control capabilities. f. 1ea 1/8 stereo mini to serial DB-9 adaptor (P/N 7600219) g. 1ea HDMI Retention Bracket h. Quick Install Guide (this document) The ELAN g! Training Guide contains valuable hardware and software reference documentation and is considered an important supplement to this document. You would have received the training guide while attending g!School, however the ELAN g! Training Guide is updated regularly. Make sure you have the latest version by visiting the ELAN Dealer website at www.elanhomesystems.com and following the dealer link. Note: The g1 does not have a ViaNET connection. If your installation has devices that require ViaNET communication you will need to connect an ELAN SC1 to the serial RS-232 port. Figure 3-7: Sense Inputs www.elanhomesystems.com 1 Mount the g1 in the desired location The g1 is designed to mount on a shelf, hang in a cabinet or rack, or mount in a structured wiring enclosure. Shelf Mounting: The g1 has rubber feet to protect nished surfaces. Set the g1 in a location that will allow you to properly manage connected wiring so that tension is not placed on the connections. The g1 is relatively small and wire tension will cause the unit to move and may cause wires to become disconnected. Wall Mounting: The g1 chassis has been designed to allow convenient wall mounting in any orientation. The g1 wall mounts using standard sheetrock type screws (not included). It is recommended that the g1 be mounted to wood. When mounting the g1 to sheetrock, appropriate anchors are recommended. Arrows on the rear panel may be used to mark the location for the screws. Mark the screw locations, mount the screws leaving approx. 3/16 (5mm) of screw exposed and slide the g1 over the screws. ELAN 2010 | All rights reserved. Use arrows to mark screw holes. Use guides and mark it with a pen WALL 3/16 5 mm Leave a 3/16 gap between screw heads and wall. 2 7 in. Serial Connections Connect an RS-232 serial controlled device using the included 1/8 mini to DB9 adaptor. The g1 serial output is not compatible with RS-485 serial devices. If your project requires RS-485 connections you will need to use a gSC10 controller. RECESSED RESET BUTTON 1 7/8 in. 1 in. ELAN RS-232 Adapter:
P/N: 7600219 3 15/16 in. 5 in. 5 6 2 RS-232 wiring pin-outs are as follows:
HC4/HC8 INSTALLATION MANUAL C Sense Input Connections A B KEY :
A. Tip B. Sleeve C. Ring NC TX RX GND NC NC NC NC NC 3 4 5 6 7 The Sense Inputs of the HC4 (2) / HC8 (4) are used to conditionally execute macros and to trigger Event Maps that have been programmed into the System Controller using the ELAN configuration software. 8 9 When used with a conditional macro the sensor is connected to the device being monitored. The ELAN configuration software can be used to create a macro that checks the status of the sensor prior to issuing a command. This conditional programming can be used to prevent a TV, for example, from being inadvertently turned on or off when changing sources or turning a zone on or off. 1 2 5 4 3 2 1 9 8 7 6 3 Event Maps can be programmed that execute a command or sequence of commands when a Sense Input is triggered. For example, a driveway sensor can be used to activate an ELAN contact closure sensor to trigger an Event Map that turns on the outside lights. The status of a light sensor can be used to make the triggering of the Event Map conditional. If it is daytime the lights dont come on. If it is nighttime, they do. Sense Input Connection ELAN sensors can be used to input a status from 3rd party devices. The status is binary, either ON or OFF. This can be used to trigger an event map or as a condition of an event map. Connect ONLY an ELAN sensor to this port. The HC4/HC8 provides +5 VDC to the TIP (VSNS) connection to power the Sensor. When the Sensor is activated, it shorts the ring (SNS) to the sleeve (GND) thereby triggering the HC4/HC8s Sense Input. See Figure 3-7. 4 IR Outputs Three discrete IR outputs are supplied to control third party Available ELAN sensors include: AUDIO, VIDEO, CONTACT CLOSURE, and VOLTAGE, LED/LIGHT, and CURRENT/MAGNETIC FIELD sensors. devices. The outputs may be con gured in g! programming to utilize a carrier or not. Each output is compatible with Xantech single and dual emitters. ELAN Sensor AUD Sensor P/N: AUDSENSOR VID Sensor P/N: VIDSENSOR CT Sensor P/N: CTSENSOR CR Sensor P/N: CRSENSOR LT Sensor P/N: LTSENSOR VT Sensor P/N: VTSENSOR DVD Media Player 7 8 9 10 11 12 OSD The g1 supplies an On Screen Display (OSD) interface via HDMI. Connect the OSD output to an available input on either your monitor or your AVR. Note which monitor/AVR input is used. It will be needed when con guring the OSD. Installing the HDMI Retention Bracket A bracket is included to assist in keeping the HDMI cable plugged into the g1. After inserting the HDMI cable, remove the screw above the HDMI connector and use the screw to secure the HDMI Retention Bracket to the g1. Depending on the size of your HDMI cable you may need to use a small wire tie to hold the cable to the bracket. Cable bracket Zip tie USB connection Some accessories may be connected to the g1s USB connector. Refer to the ELAN Integration Note for the device prior to connection. LAN/POE Connection Connect the Ethernet connection to an available 10/100 Mbps port on the network. This is the preferred connection. The g1 may be powered over Ethernet (PoE). PoE connection must meet the minimum requirements of IEEE 802.3at, Type I (48 VDC, 350 mA). RESET Switch Located on the underside of the unit is the recessed RESET switch. When pressed momentarily the RESET switch will clear the static IP setup and return the g1 to DHCP as well as reset the WiFi con guration to factory default. When pressed and held for more than 15 seconds the programming of the current g!
software version will be reset to default. Pressing RESET while applying power will reset the software to the factory version. WARNING! THIS CANNOT BE UNDONE!!!
RESET TEST The TEST connection is for factory and repair access only. Do not plug anything into the TEST port. Plugging anything into the TEST port will void the warranty and release the magic smoke. Power Connection Once all other connections have been completed connect the 12VDC power supply or PoE Ethernet input and engage the power switch on the front of the g1. Page 24 TV PoE Connection 12V Power Connection Audio Connection The AUDIO out connection on the g1 is for future use. IR Input Connection Plug the included Xantech DL95 IR sensor into IR IN. The g1 supplies power to the IR receiver. Other Xantech IR sensors are compatible with the g1 should your application require it. The g1 is fully compatible with ELANs Wi-Fi hand held remote controls and smart device interfaces. If using one of these devices as the primary control interface for the g1 it is not necessary to install the IR sensor. NOTE: If you do not install the IR senor the included IR remote will not work. GND (RING)
+12VDC (SLEEVE) IR SIGNAL (TIP) 13 Connecting to the g1 on your wired network The g1 is set from the factory for DHCP networking, which means it receives its IP address from the network router. Use g!Tools to nd the address and connect to the g1. Connecting to the g1 on your wireless network The g1s wireless radio may be con gured by rst connecting the unit to a wired network connection and following the wireless con guration instructions found in the ELAN g! Training Manual or using the OSD. To con gure via OSD turn on the TV, select the g1 HDMI input, then point the g1 remote at the IR sensor and press then MUTE then ENTER in quick succession. Follow the on-screen instructions and using the g1 remote enter the appropriate network information. Once completed you will be able to access the g1 from your laptop and g!Tools using only the WiFi network. 14 Software upgrade Prior to con guring the product, upgrade the g1 software to the latest version of g! Core Module. Core Module can be found on the ELAN dealer website. The g1 is not compatible with g! Core Module releases prior to g!7.0. 9901340_ELAN_QuickGuide_g1_ENG_0523_PRINT.indd 4 5/23/14 5:36 PM