3222 Phoenixville Pike, Suite 200
Malvern, Pennsylvania
TEL: 1 610 430 2700
ALIO Note Installation
and User Guide
1 | P a g e
Page
Introduction……………………………………………………………………………………3
Specifications………………………………………………………………………………….3
Part List…………………………………………………………………………………………..3
Warnings………………………………………………………………………………………..3
Cleaning………………………………………………………………………………………….3
Installation…………………………………………………………………………………..4-8
Operation……………………………………………………………………………………….8
Diagnostics……………………………………………………………………………………..9
LEDs Status……………………………………………………………………………………..9
Troubleshooting……………………………………………………………………………10
Regulatory…………………………………………………………………………………...10
SERIAL NUMBER CONFIGURATION
WWYLCCPPPPP
WW - Week Manufactured (01 through 52)
Y - Year Manufactured (2 for 2002)
L - Manufacturing Location
CC - Configuration Code
PPPPP - Sequential Production Number
Contents:
2 | P a g e
INTRODUCTION:
ALIO Note is the next generation cashless and telemetry system from CPI
that combines a telemeter, antenna, card reader and a full color display into a
single device.
Specifications:
Input Voltage
Input Current
Operating Temperature
Dimensions (bezel)
Weight (bezel & Hub)
20-42 VDC
Max – 1 Amp
(-15°) - +60°C
160mm x 80mm x 40mm
379 Grams (0.83 Lbs.)
Parts List:
Part Description
MDB Cable
DEX Cable
Mounting Plate
Part Number
250670036C
215637033C
250038091
When mounting the ALIO Note bezel onto the Talos bill validator ensure
Observe ESD precautions when mounting the ALIO Note to the Talos bill
WARNINGS:
that all power is off.
validator. Serviceman should be properly grounded.
CLEANING:
use abrasive or flammable cleaners.
If the bezel should need cleaning use only mild soap & warm water. Do not
3 | P a g e
INSTALLATION:
Step
Process
1
2
3
Turn off power to
the vend- ing
machine
Remove the
existing bill
validator
Remove the
existing
telemeter
Unscrew the four hex nuts from the mounting posts with the 11/32 nut
driver, and disconnect any cabling.
Disconnect all connections to the telemeter and remove the antenna from
the top of the vendor.
Because ALIO Note’s antenna is contained within the bezel, there is no need
to run an antenna through the top of the machine.
When removing an existing antenna, follow your company’s procedure for
sealing the antenna hole.
4
Remove the Bill
Validator
control board
cover.
Unscrew the control board cover, and pull to remove. If the ex- isting bezel is
connected to the control board via a ribbon cable, disconnect the ribbon
cable before proceeding.
4 | P a g e
INSTALLATION CONTINUED:
5 | P a g e
INSTALLATION CONTINUED:
6 | P a g e
INSTALLATION CONTINUED:
7 | P a g e
INSTALLATION CONTINUED:
OPERATION:
ALIO Note is fully configured for operation from the factory and once
mechanically installed onto Talos bill validator and powered it will connect to the
cellular network ready for use. Detailed information of connection status can be
viewed by pressing the red “X” on the ALIO Note display 5 times. The display will
reconfigure to indicate the status.
Once connected, “Please Tap or Swipe Card” will be displayed and the ALIO Note
is ready to accept cards for transactions.
8 | P a g e
DIAGNOSTICS:
Once ALIO is installed, you can perform basic diagnostics on the device by
pressing or holding the large button in the center of ALIO Hub:
LEDS STATUS:
ALIO Hub has an LED ring around the CPI logo that will change colors,
depending on the current state of ALIO.
9 | P a g e
TROUBLESHOOTING:
Hold ALIO Hub button for three seconds to access the driver menu, then
scroll to the alarm section to view recent issues. The steps below will also help to
confirm proper installation.
Before Installation
1. Confirm the Asset or Equipment Number and make sure you are at the correct
machine
After Installation
1. Confirm the vending machine firmware is approved by CPI and matches the
asset assigned in the vendor system
2. Confirm that ALIO powers up properly after restoring power to the vendor
Confirm Connections
1. Confirm all connections are routed to ALIO Hub and are firmly secured
2. Confirm there is only one DEX jack active in the machine (on VMC or extended)
3. Check all connections on the VMC MDB line
Regulatory:
ALIO Note, FCC ID: QP8ALIONOTEVZ (Verizon Network Operation)
ALIO Note uses radio energy to communicate vending transaction activities
to a remote host. CPI has not approved any changes or modifications to ALIO
Note. Any changes or modifications could void the user’s authority to operate the
equipment. See 47 CFR Sec. 15.21
ALIO Note complies with 47 CFR Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesirable operation.
Guidance – Pacemakers, Potential Interference –
Radiofrequency energy (RF) from cell phones can interact with some electronic
devices. This type of interference is called electromagnetic interference (EMI). For
10 | P a g e
this reason, FDA helped develop a detailed test method to measure EMI of
implanted cardiac pacemakers and defibrillators from cell phones. This test
method is now part of a standard sponsored by the Association for the
Advancement of Medical Instrumentation (AAMI). This standard will allow
manufacturers to ensure that cardiac pacemakers and defibrillators are safe from
cell phone EMI.
The FDA continues to monitor the use of cell phones for possible interactions with
other medical devices. Should harmful interference be found to occur, FDA will
conduct testing to assess the interference and work to resolve the problem.
For more information reference sources for pacemakers can be found at U.S.
Food and Drug Administration web site: www.fda.gov , see Radiation-Emitting
Products and procedures, Interference with Pacemakers and Other Medical
Devices
-----------------------------------------------------------------------
Except as permitted under the relevant local legislation, no part of this publication
may be copied, transmitted, transcribed, or distributed in any form or by any
means, or stored in a database or retrieval system, or translated in any language
(natural or computer), without the prior written permission of CPI.
CPI reserves the right to change the product or the product specifications at any
time. While every effort has been made to ensure that the information in this
publication is accurate, CPI disclaims any liability for any direct or indirect losses
(howsoever caused) arising out of use or reliance on this information. This
document does not necessarily imply product availability. Note: Your product may
differ slightly from some of the illustrations in this document.
CPI Corporate Headquarters
3222 Phoenixville Pike Suite 200
Malvern, PA 19355
www.CranePI.com
For Technical Support, call:
1-800-628-8363 or visit:
www.CranePI.com/Support
11 | P a g e