ZUMMESH-JBOX Zm J-Box Load Controller Installation Guide Description SPECIFICATION DETAILS Additional Resources ZUMMESH-JBOX-20A-PLUG Wiring The Crestron junction box-mounted zone controllers deliver intelligent lighting control with essential features for energy efciency. Available for 20 A switching, 5 A or 16 A 0-10 V dimming, and 20 A plug load control, each ZUMMESH-JBOX model wirelessly connects to Zm daylight sensors, occupancy sensors, vacancy sensors, keypads, and dimmers (all sold separately) over the Zm mesh network, providing intelligent lighting control based on the amount of natural light and the presence of people in a space. The Zm J-Box Zone Controllers offer a powerful lighting control solution for every space within the Zm network. A basic single-room Zm system consists of Zm mesh devices, i.e., dimmers, switches, keypads, and sensors. The Zm mesh devices in the room communicate directly with each other without the need for a centralized gateway or processor. To monitor or control the room from a centralized Crestron control system, use the ZUMMESH-NETBRIDGE. NOTE: The ZUMMESH-NETBRIDGE requires a J-box device to provide power. For quick network setup, use the Zm app on a smartphone or tablet. Power Requirements Line Power Idle State Power Consumption Expansion Port SKUs 100-277 Vac, 50/60 Hz 1 W Expansion port allows connection of an accessory such as a Zm Network Bridge
(ZUMMESH-NETBRIDGE) or HVAC Contact Closure Module (ZUM-CCO) ZUMMESH-JBOX-16A-LV /
ZUMMESH-JBOX-5A-LV Switched Output 16 A at 100-277 Vac, 50/60 Hz (20 A, de-rated to 80%) 5 A at 100-277 Vac, 50/60 Hz 0-10V Output 60 mA Sink or Source DIM Load Type Functionality Expansion Port LED driver (4-wire), Fluorescent, Incandescent, MLV, ELV Controlled by keypads, occupancy or vacancy, and daylight sensors. Allows connection of Zm Network Bridge or Relay Contact Closure Module ZUMMESH-JBOX-20A-SW Switched output 20 A high in-rush (de-rated to 80%), zero cross switching Visit the product page on the Crestron website (www.crestron.com) for additional information. Use a QR reader application on your mobile device to scan the QR image. Installation WARNING: To avoid re, shock, or death, turn off the power at the circuit breaker or fuse and test that the power is off before wiring!
NOTES: Observe the following points:
Install and use this product in accordance with appropriate electrical codes and regulations. A licensed electrician should install this product. To install a switch or dimmer, do the following:
1. Turn the power off at the circuit breaker. 3. Mount the J-box device to the J-box. 2. Wire the device as shown in the following diagrams. ZUMMESH-JBOX-5A-LV, ZUMMESH-JBOX-16A-LV, and ZUMMESH-JBOX-20A-SW Wiring 100-277 Vac power from breaker Neutral (white) Hot (black) 15 or 20 A receptacle Neutral (white) Switched output (red) Hot (black) to unswitched receptacles Switch Load Types 0-10 V LED driver, Fluorescent ballast (4-wire), 60 mA max current sink or source Functionality:
Expansion Port:
Controlled by keypads and occupancy or vacancy sensors Allows connection of Zm Network Bridge or Relay Contact Closure Module ZUMMESH-JBOX-20A-PLUG 100-277 Vac power from breaker Neutral
(white) Hot (black) Switched output Functionality Expansion Port 20 A high in-rush, zero cross switching for control of receptacles Controlled by occupancy or vacancy sensors to energize receptacles when the room is occupied. Note that the output defaults to energized state after a power cycle. Allows connection of Zm Network Bridge or Relay Contact Closure Module ZUMMESH-JBOX-PSU Wiring To 0-10 V Controlled load Neutral (white) Switched output (red) 0-10 V dim + (purple) 0-10 V dim - (gray) 100-277 Vac power from breaker Neutral (white) Hot (black) ZUMMESH-JBOX-PSU Functionality Expansion Port Enclosure Housing Mounting Environmental Temperature Humidity Dimensions Height Width Depth Weight Provides power for Zm Network Bridge when other J-box devices are not available. Allows connection of Zm Network Bridge or Relay Contact Closure Module Plastic, white, UL standard 5VA rated Mounts in a 4 x 4 junction box via 1/2 in conduit knockout;
Rated for mounting in plenum spaces, UL standard 2043 32 to 104 F (0 to 40 C) 10% to 90% RH (noncondensing) 3.25 in (83 mm) 4.17 in (106 mm) 1.31 in (33 mm) 0.4 lbs (7 oz) NOTE: The 010 V dim - and 010 V dim + wires are not present on the ZUMMESH-JBOX-20A-SW. Test the Loads Press the TEST button to toggle the connected loads. Press and hold the TEST button to cycle dim the connected loads (dimmer models only). Preliminary Basic Room Setup A basic single-room Zm system consists of Zm mesh devices, i.e., dimmers, switches, keypads, and sensors. The Zm mesh devices in the room communicate directly with each other without the need for a centralized gateway or processor. To set up a new single-room Zm system, do the following:
Step 1a: Create a new single-room Zm system. Step 2: Add Zm mesh devices to the room. Step 3: Finish creating the single-room Zm system. To modify an existing Zm system, do the following:
Step 1b: Place the system in Joining mode. Step 2: Add Zm mesh devices to the room. Step 3: Finish creating the single-room Zm system. Step 1a Creating a Single-Room Zm System To create a new single-room Zm system, rst form a new room. NOTE: This can be performed on only one device in the room. NOTE: The device that is used to create the room is automatically added to the room. The device does not need to be added to the room. NOTE: A room can be created only from an ac-powered device. Start a New Single-Room System with a Keypad, Dimmer, or Switch Press the bottom button 5 times, and then press and hold the bottom button for 2 seconds. If the device is not factory fresh, hold the button for 10 seconds. Release the button when the LED lights. The LED illuminates for 3 seconds and then slowly ashes to indicate that the room is in Joining mode and that other devices can join the room. 2s or 10s Start a Single-Room System with a J-Box Device Press the SETUP button 5 times, and then press and hold the SETUP button for 2 seconds. If the device is not factory fresh, hold the button for 10 seconds. Release the button when the LED lights. The LED illuminates for 3 seconds and then slowly ashes to indicate that the room is in Joining mode and that other devices can join the room. Step 1b Expanding an Existing Single-Room Zm System To allow other devices to join the room, place the single-room Zm system into Joining mode. Joining mode can be enabled from any ac-powered device or battery keypad that is already part of the room. Expand a Single-Room Zm System Using a Keypad To enter Joining mode, press and hold both the top and bottom buttons for 5 seconds, wait for the LED to light, and then tap the top button once, and then the bottom button once. Factory Reset Install Network Bridge Perform a factory reset when the device is removed from the network or to remove the conguration settings. The device must also be factory reset if the device is being moved to a different system. NOTE: New-in-box devices do not need to be factory reset before joining a system. To factory reset the device, press and hold the TEST and SETUP button for 10 seconds. Release the button when the LED lights. The LEDs and output will turn on. The Zm Network Bridge enables Zm device setup from a mobile app and integrates a stand-alone Zm lighting control system with the Zm hub (not supplied) for a centrally managed, enterprise-wide lighting control system. The network bridge can be installed to any J-box device. 1. Using a at-head screwdriver, remove the cover on the J-box device. 2. Ensure that the connector on the network bridge is aligned with the expansion port on the J-box, and then insert the network bridge into the J-box device. The network bridge snaps into place. 5s Expand a Single-Room Zm System Using a J-box Device To enter Joining mode, tap the SETUP button 2 times, and then tap the TEST button. SETUP TEST 10s SETUP TEST SETUP TEST Pressing any button on a device that is part of the network takes the system out of joining mode. Joining mode ends automatically after 4 minutes. Step 2 - Adding Zm Mesh Devices to the Room Adding Zm mesh devices to a room is quick and easy. Add devices to the room when the room is in Joining mode. Joining mode is automatically enabled after a single-room Zm system is started (see Step 1a). Joining mode can also be enabled manually (see Step 1b). The LEDs on all ac-powered devices in the system blink when the system is in Joining mode. NOTE: A Zm mesh device can belong to only one room. NOTE: The Zm mesh device used to create the room is already part of the network. It does not need to be added to the network. To add a J-box dimmer or switch to the room, press the SETUP button 3 times, and then press and hold the SETUP button for 2 seconds. If the device is not factory fresh, hold the button for 10 seconds. Release the button when the LED lights. The LED blinks slowly to indicate that it is part of the room and that the room is still in Joining Mode. 100-277 Vac power from breaker Neutral (white) Hot (black) If necessary, the network bridge can be easily removed. To remove the network bridge, do the following:
1. Between the J-box and the J-box device, press the side of the network bridge with your thumb away from the J-box. 2. While pressing on the side of the network bridge, slightly lift the network bridge up and out of the J-box device. The network bridge should easily remove from the J-box device. SETUP TEST 2s or 10s SETUP TEST 2s or 10s Step 3 - Finishing the Single-Room Zm System Press any button on a device that has already joined the network to end the setup process (e.g., the top button of a keypad or the SETUP button of a J-box device that is blinking its LED). SETUP TEST This product is Listed to applicable UL Standards and requirements tested by Underwriters Laboratories Inc. Ce produit est homologu selon les normes et les exigences UL applicables par Underwriters Laboratories Inc. Federal Communications Commission (FCC) Compliance Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions:(1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modications not expressly approved by the manufacturer responsible for compliance could void the users authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the receiver is Increase the separation between the equipment and receiver. connected. Consult the dealer or an experienced radio/TV technician for help. Industry Canada (IC) Compliance Statement CAN ICES-3(B)/NMB-3(B) This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body Cet quipement doit tre install et utilis une distance minimale de 20 cm entre le radiateur et votre corps. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. The product warranty can be found at www.crestron.com/warranty. The specic patents that cover Crestron products are listed at patents.crestron.com. Certain Crestron products contain open source software. For specic information, please visit www.crestron.com/opensource. Crestron, the Crestron logo,and Zm are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. UL and the UL logo are either trademarks or registered trademarks of Underwriters Laboratories, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography. This document was written by the Technical Publications department at Crestron. 2017 Crestron Electronics, Inc. Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Installation Guide - DOC. 7863B
(2048125) 11.17 Specications subject to change without notice. Preliminary