TracSafe MAX User Manual Multi-use Data Logger Summary The CSafe TracSafe MAX Shipment monitor is used to monitor and record temperature and location data associated with temperature sensitive product shipments. The data can be viewed without disturbing the protective thermal packaging by employing Bluetooth Low Energy technology, that allows touchless temperature checks of in-transit shipments using a smart phone or tablet via the CSafe TracSafe app (iOS or Android). It enables direct monitoring of the temperature-sensitive products during the shipment or storage phases and can easily identify if the tempera-
tures hava been maintained at the end destination. The TrcaSafe MAX also has integral LCD display to view the temperature status and notications via the recessed function buttons.The device also includes a USB port that can be used to directly download the shipment data or congure the shipment alarm limits prior to the shipment using a PC, for users without access to a smart phone or tablet. USB cap Light Sensor LCD Screen Start / Stop Button Internal Sensor External Probe 1 Specication 1.Measurement range:
Internal temperature: -30~70 Internal humidity: 0%RH~100%RH External temperature: -200~150 Shock: 0g~16g Light: >80Lux 2.Accuracy arrange:
Temperature: 0.3(-20~40)0.5(50~85)1(-100~150)2(others) Humidity: 3%RH(25,20%RH~80%RH)5%RH(others) Shock: 0.5g Light: 5%
3.Resolution: Temperature: 0.1, humidity: 1%RH, shock: 0.1g 4.Memory Storage Capacity: 32,000 data points (MAX) 5.Logging interval: 3min~60min 6.Start mode: Button push, immediate start, or start delay, useTracSafe APP or CSafe pc software 7.Stop mode: Button push, stop when inserted into pc, stop when memory is full,use TracSafe APP or CSafe pc software 8.Alarm Limits: 1 high and 1 low limit for temperature/ 1 high and 1 low limit for humidity Alarm type: Single, cumulative 9.Alarm type: Single, cumulative 10.Alarm delay time: 10s~24H 11.Connection: USB, Bluetooth 12.Battery Life / Type: 12 month operating life, Lithium replaceable battery, VCC:3.6VDC 13.Environmental Protection: IP65 (non probe version),IP54 (probed version) 14.Dimensions: 96.3 mm(L) x 47.5 mm(W)x 19 mm(H) (non probe version) 103.3mm(L)x 47.5 mm(W)x 19 mm(H) (probe version) 15.Weight: 68g 16.Bluetooth: Operating Frequency: 2402MHz~2480MHz Rated Output Power: 0dBm 2 Operation Instructions for PC 1.Download CSafe software
(In this part, we need to add the website which can download CSafe software) 2.Congure Parameter Plug the device into the computer, until USB symbol is shown on the LCD screen. Using CSafe software to congure parameter:
If users dont need to change the default parameter, you can click Summary and then click Quick Reset to synchronize time. If use need to change the parameter, you can click Parameter, click Save Parameter after conguration. Notice:
To avoid time/time zone errors, please click Quick Reset or Save Parameters before the rst use or after replacing the battery to ensure that the local time is congured into the recorder. 3.Start Modes Press button:
Press START button for 3 seconds, Use CSafe APP/software to start. Notice:
shows on the LCD screen. symbol blinks continuously, it indicates start delay has been set. 4.Stop Modes Press button: Press STOP button for 3 seconds, shows on the LCD screen;
Auto stop: Stop when memory is full;
USB stopStop after plugging the device into computer;
Using CSafe APP or software to stop. Notice:
Press button to stop is default option, this function can be changed if necessary. 5.Download Data Plug device into computer and wait until USB symbol shows on the LCD screen:
1. User can review the PDF and CSV report in the drive which is generated by the device. 2. Using CSafe software to download the data: the data will be uploaded to CSafes platform automatically after downloaded via softwareIf it fails to upload data automatically, please click "Loading" to upload manually. 6. Reuse User can re-congure and start logging after stop device or export the complete data. Notice:
The history data will be cleared about saving parameter. User can click History in CSafe to review the history data if user forget to save/download data. 3 Operation Instruction for CSafe APP 1.Turn on Bluetooth Press START and STOP buttons simultaneously for 3 seconds until the two LED lights blink at the same time and shows on the LCD screen. 2.Download CSafe APP The user can download the CSafe TracSafe APP in iOS APP store or Google Play for Android User needs to register according to the prompts. 3.Conguration and logging Click Loggers tab to review the device list that are within range. Press the stop button then the device will be moved to the top of the device list and the background would become orange. Click Cong to congure the parameters then click Save. Click OK to nish conguration. After conguration, click the device and then click Start tab to start logging. 4 4.Read & download data Click in Loggers page to refresh the device list and click Read data. After the data has been read completely user can click stop to stopping logging; Click Data tab to review the history data; user can download PDF and CSV reports via clicking Download data tab. 5.Quick operations via scanning the bar code on the device In Loggers page, click the to scan the bar code on the device and then user can start quick operations (Start, Cong, Read data) 5 Status indication 1.Button functions Function Operation LED Start logging Press START button for 3s blink 5 times Stop logging Press STOP button simultaneously for 3s blink 5 times Press START and STOP button for 3s red and green LED blink 5 times at the same time Switching the LCD pages Press START button
(or )blink once(or twice) Back to LCD main page Press STOP button
(or )blink once(or twice) 2.LCD screen Status of logging MAX, AMB, MIN Bluetooth Battery Temperature value Sample # Humidity value/total sampling points Shock Status of external probe Light 6 LCD interface 1. Not started 5. MAX B R R R 2. Start delay 3. Started 4. Stopped R R 6. MIN 7. Generating reports 8. USB connected P #
9. Internal sensor error 10. External sensor error 11. Re-save parameters 7 LCD symbols Function Started Stopped No alarm Alarm External probe is connected. External probe error Bluetooth is turned on. Note:
1. Please store the device in a room temperature environment. 2. When using the device for the rst time, be sure to connect the computer for parameter conguration to synchro-
nize time. 3. Please do not take out the battery when recording. the screen again if necessary. 5. After conguration, the history data will be cleared. Please read and save the historical data of the device before conguration. 6. To ensure humidity accuracy, please avoid contacting unstable chemical solvents or other chemical compounds, especially avoid long-term storage or exposure to high concentration of ketene, acetone, ethanol, isopropanol, toluene and other environments. 7. When the battery symbol on the LCD is less than two bars, please do not use it for long-distance transportation. 8. Please enable the Bluetooth function before connecting the device via TracSafe APP. 8 Note Factory default parameters Items Logging interval Start mode Start delay Press button to stop Temporary PDF Temperature units LCD display time LCD main page display time LCD other pages display time LED blink Time zone Light sensor Shock sensor Probe type Alarm type Alarm delay Temperature high limit H1 Temperature low limitL1 Humidity high limit Humidity low limit Default parameter 5 min Press button to start No start delay Enabled Enabled C 15s 60s 3s No blinking UTC-05: 00 Not enabled Not enabled Probe : External & Internal Temperature Device : Internal Temperature Single No delay 8C 2C Not enabled Not enabled 9 FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of t he FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled Environment. IC Caution The device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance. This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device. This equipment should be installed and operated with a minumum distance of 20 cm between the radiator and your body. Le dispositif rencontre l'exemption des limites courantes d'valuation dans la section 2.5 de RSS102 et la conformit l'expostion de RSS-102 rf, utilisateurs peut obtenir l'information canadienne sur l'exposition et la conformit de rf. Lmetteur/rcepteur exempt de licence contenu dans le prsent appareil est conforme aux CNR dInnovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) Lappareil ne doit pas produire de brouillage;
(2) Lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionne.