WX SENSOR User Manual Desk Configuration Ceiling Configuration ENVIRONMENTAL RECOMMENDATIONS Your device is made of materials that can be recycled and reused if dismantled by a specialized firm. Please follow local regulations on how to dispose of old packaging materials, used batteries and your previous device. WARNINGS The safety provided by this product is only guaranteed for an intended use to its purpose.
- Read the instructions in the manual.
- Maintenance can only be carried out by qualified staff.
- Caution : Do not install equipment near a heat source or a humidity source.
- Caution : When the equipment is open, do not perform operations other than those provided in this manual. CE standard : This product is certified and complies with european regulations. FCC standard : This product is certified and complies with the regulations of the Federal Communications Commission in the United States. IC standard : This product is certified and complies with canadian regulations. IDA standard : This product is certified and complies with singaporean regulations. Please read the enclosed user and safety instructions before using your device for the first time. Recycling : Do not dispose of in landfill or in a garbage container. Please comply with the current legislation for disposal. Use of direct voltage (DC) Do not use this device under conditions other than those described in the technical specifications. Risk of fire or explosion in these cases :
Do not recharge the battery
Do not short-circuit the battery If the device is used for purposes not specified by the manufacturer, the safety of the sensor may be called into question. Table of contents Table of contents ____________________________________________________________ 1 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Product description ____________________________________________________ 2 Installation of the product in Desk configuration _____________________________ 3 Installation of the product in Ceiling configuration ____________________________ 4 Field of view of the presence measurement _________________________________ 6 Field of view of the counting measurement _________________________________ 7 Start up the product ____________________________________________________ 8 Product configuration __________________________________________________ 8 Infrastructure _________________________________________________________ 8 Technical characteristics ________________________________________________ 9 Certification _________________________________________________________ 10 Human exposure to radio frequencies_____________________________________ 11 12. Notes about the batteries ______________________________________________ 11 13. 14. Commercial references ________________________________________________ 12 Technical support _____________________________________________________ 13 1 1. Product description Part of the Transform Together range, the WX SENSOR provides wireless measurement and transmission of presence information at a workstation or in a room. It can also, optionally, measure the number of people present in a space. The sensor is equipped with a bolometer that delivers 6400 temperature points over an area of 15 to 20m. A CSM algorithm transforms these measurements into a number of people present in the room. Its characteristics make it compatible with different real estate needs such as the information of the availability of a workstation or a room in real time, the analysis and optimized management of surfaces according to criteria specific to the equipped building. The absence of wiring and its small footprint allow a quick and easy installation of the sensor on almost all types of surface. The available functions are :
1) Occupancy measurement 2) Counting 3) Pull-out monitoring 4) Auto-location 5) Bluetooth beacon 6) Battery level monitoring 7) Transmission of information through LPWA Sigfox ou LoRa networks 8) Configuration via Bluetooth Configuration Desk Configuration Ceiling Bolometer sensor for counting measurements PIR sensor for presence measurements BLE pairing button Pull-out monitoring 2 2. Installation of the product in Desk configuration In this configuration, the WX SENSOR can be installed in all types of furniture with a flat, melamine, laminate, glass or metal coating. When ordering, it will be necessary to specify the desired installation kit :
1) Double-sided adhesives (ref VHB 4991 at 3M). 2) Wood screw Support Wood (raw, melamine, laminate) Metal Plastic Type of final fixation Adhesive - Screw Adhesive Adhesive Type of fixation location Adhesive - Srew Adhesive Adhesive In case of the use of double-sided adhesive, the surface receiving the sensor will be cleaned beforehand with isopropyl alcohol in order to have an optimal bonding. Locations for adhesive Installation label Product label Holes for wood screws In addition to the particular shape of its mechanics, it will be possible to identify a desk product thanks to :
1) The commercial reference indicated on the product label (see chapter Commercial References ) 2) The color of the installation label text :
In the Sensor Management mobile app, a desk object is symbolized by the icon :
3 3. Installation of the product in Ceiling configuration In this configuration, the WX SENSOR can be installed on most types of ceiling (plaster, suspended ceiling, concrete, cable tray, etc.). When ordering, it will be necessary to specify the desired installation kit :
1) None 2) Double-sided adhesives (ref VHB 4991 at 3M). 3) Small magnet (Neodymium disc magnet 20 mm, height 5 mm adhesive strength 6kg) 4) Big magnet (Neodymium disc magnet 25 mm, height 7 mm - adhesive strength 11kg) If no fixing kit is required, the installer must use one the following fasteners :
1) Threaded rod diameter M5 or M6 2) Large round head metal screw. M5 3) Twist fixing clip with integrated threaded rod M6 4) Molly pin + Threaded rod M5 ou M6 5) Stell and spiral fixing of X mm + large round head metal screw. M5 Support Type of final fixation Type of fixation location Plaster Metal, cable tray Fineline Rail suspended ceiling Suspended ceiling Rail T24 Concrete Cork acoustic plates Big magnet Molly pin Small magnet Small magnet - Round head machine screws Small magnet - Twist fixing clip Threaded rod Big magnet Small magnet Small magnet - Round head machine screws Small magnet - Twist fixing clip Threaded rod Steel and spiral fastening Steel and spiral fastening In case of the use of double-sided adhesive, the surface receiving the sensor will be cleaned beforehand with isopropyl alcohol in order to have an optimal bonding. Do not use the adhesive on painted, dirty or friable surfaces. In general, the use of adhesive to fix a sensor to the ceiling is strongly discouraged. The installer must check that the product is properly fixed for user safety. 4 Location for adhesive Installation label Location for threaded rod M5 or M6 Product label Location for magnets We will differentiate the different ceiling product thanks to :
1) The commercial reference indicated on the product label (see chapter Commercial References ) 2) The color of the installation label text for un product :
a. Performing presence measurements and counting :
b. Performing presence measurements and no counting :
c. Performing neither presence measurement nor counting :
In the Sensor Management mobile app, a Ceiling object :
1) Performing presence measurements and counting is symbolized by the icon :
2) Performing presence measurements and no counting is symbolized by the icon :
3) Performing neither presence measurement nor counting is symbolized by the icon :
5 4. Field of view of the presence measurement The WX SENSOR covers a circular surface whose dimensions will vary depending on the ceiling height according to the diagram below :
Field of view of the counting sensor WX SENSOR Installation height Installation height 0,70 m 2,20 m 2,40 m 2,70 m 3,00 m Ground presence area 0,6 m ( 0,9m) 20 m ( 5m) 23 m ( 5,4m) 29 m ( 6,1m) 36 m ( 6,8m) In order to have a reliable counting measurement, the measurement area must not be blocked by objects such as suspended lights or other objects. 6 5. Field of view of the counting measurement The WX SENSOR covers a square surface, whose dimensions will vary depending on the ceiling height according to the diagram below :
Field of view of the counting sensor WX SENSOR Ceiling height Ceiling height 2,20 m 2,40 m 2,70 m 3,00 m Counting area 70 cm from the ground 9 m (3m x 3m) 10 m (3,1m x 3,1m) 14 m (3,7m x 3,7m) 18 m (4,2m x 4,2m) Counting area on the ground 16 m (4m x 4m) 19 m (4,3m x 4,3m) 24 m (4,9m x 4,9m) 30 m (5,5m x 5,5m) In order to have a reliable counting measurement, the measurement area must not be blocked by objects such as suspended lights or other objects. 7 6. Start up the product The product will be delivered and configured in an operating mode blocking all radio frequency communication. During installation, before fixing the sensor to its support, the installer must press the pairing button in order to switch the product to nominal operation. Configuration Desk Configuration Ceiling BLE pairing button 7. Product configuration To be able to re-configure a product, there are two solutions :
1) Use the downlinks : see the CSM portal documentation 2) Use the Sensor Management app : see the Documentation of the Sensor management Application 8. Infrastructure WX SENSOR data is transmitted by radio frequency through Sigfox or LoRa Networks. The antenna network must be sized to allow good communication of all the building's sensors. 8 9. Technical characteristics Functionnal Mechanical Presence detection and people counting Transmission of information by radio frequency Auto-location of the product Bluetooth beacon Pull-out monitoring Easy and quick configuration by bluetooth without disassembly Updating of configuration parameters possible by physical dialogue) without downlink
(radio intervention by an operator UL94V0 white polycarbonate housing Can be fastened by double-sided adhesive tape, magnet or screws Dimensions :
o Diameter 105,1 mm o Height 23,2 mm Environmental Operating temperature : + 0C + 32C Storage temperature : + 0C + 60C Humidity : +20% to 90% HR without condensation lithium Electrical Integrated power supply by replaceable battery Battery lifetime: 5 years to 10 years depending on features and additional battery option life and Radiofrequency Frequency band :
ISM SubGiga : 863-870 MHz. / 902-928MHz /
865-867MHz ISM 2,4GHz : Bluetooth 2,4022,480 GHz Compatible with Sigfox and Lorawan UNB protocols Lorawan Regional
(Specifications v1.0.3 and Parameters v1.0.3 revA) 9 10. Certification FCC certification This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. Caution: the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on, the user is encouraged to try to correct interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. Operation of this equipment in a residential area may cause harmful interference, in which case the user will be required to correct the interference at their own expense. This device complies with FCC RF radiation exposure limits set forth for general population. This device must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna transmitter. IC certification This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) This device must accept any interference, including interference that may cause undesired operation of the device. This device complies with ISED radiation exposure limits set forth for general population. This device must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. 10 11. Human exposure to radio frequencies This equipment complies with the limits of human exposure to electromagnetic fields (EMF) for devices operating in the frequency range from 0 Hz to 300 GHz according to the EMF EN 62311 standard. 12. Notes about the batteries The WX SENSOR is equipped with one or two batteries depending on the autonomy needs desired by the customer. The commercial reference of the authorized batteries are mentioned below :
JAUCH : CR17500 model 249239 ENBAR : CR17505_2500-01 (CE only) Li / MnO2 batteries are not rechargeable. The batteries are personalized to allow their integration. When changing batteries, please contact CSM in advance to order the correct batteries. After changing the batteries, a reset of the product will be necessary (see the Documentation Sensor management Application). Battery replacement should be performed by a qualified person. Caution : There is a risk of explosion if the batteries are replaced by an incorrect reference. Dispose of the batteries according to the instructions. When changing the batteries, the product must be cleanly and correctly reassembled. 11 13. Commercial references Ccommercial references Electronical references Mechanical references Batteries WX SENSOR-NC-SR-NPA-DP-1B WX SENSOR-Sigfox without PA Mechanical Desk 1 battery WX SENSOR-NC-SR-NPA-DP-2B WX SENSOR-Sigfox without PA Mechanical Desk 2 batteries WX SENSOR-NC-SR-NPA-CP-1B WX SENSOR-Sigfox without PA Mechanical Ceiling 1 battery WX SENSOR-NC-SR-NPA-CP-2B WX SENSOR-Sigfox without PA Mechanical Ceiling 2 batteries WX SENSOR-YC-SR-NPA-CC-2B WX SENSOR-Sigfox without PA + Counting Mechanical Ceiling Counting 2 batteries WX SENSOR-NC-SR-YPA-DP-1B WX SENSOR-Sigfox with PA Mechanical Desk 1 battery WX SENSOR-NC-SR-YPA-DP-2B WX SENSOR-Sigfox with PA Mechanical Desk 2 batteries WX SENSOR-NC-SR-YPA-CP-1B WX SENSOR-Sigfox with PA Mechanical Ceiling 1 battery WX SENSOR-NC-SR-YPA-CP-2B WX SENSOR-Sigfox with PA Mechanical Ceiling 2 batteries WX SENSOR-YC-SR-YPA-CC-2B WX SENSOR-Sigfox with PA + Counting Mechanical Ceiling Counting 2 batteries WX SENSOR-NC-LR-YPA-DP-1B WX SENSOR-LoRa Mechanical Desk 1 battery WX SENSOR-NC-LR-YPA-DP-2B WX SENSOR-LoRa Mechanical Desk 2 batteries WX SENSOR-NC-LR-YPA-CP-1B WX SENSOR-LoRa Mechanical Ceiling 1 battery WX SENSOR-NC-LR-YPA-CP-2B WX SENSOR-LoRa Mechanical Ceiling 2 batteries WX SENSOR-YC-LR-YPA-CC-2B WX SENSOR-LoRa + Counting Mechanical Ceiling Counting 2 batteries PA = Power Amplifier allows to increase the transmission power for RC2 and RC4 Sigfox areas. 12 14. Technical support In order to get a technical support :
Website Mail Phone number Address www.csmres.com support@csmres.com
+33 1 45 84 33 83 CSM 62 Boulevard Diderot 75012 Paris France 13