DRINKING WATER | AGUA POTABLE ClearLink Pro Wireless Filtration Control Installation and operating instructions ClearLink Pro Control de Filtracin de Agua Inalmbrico Instrucciones de instalacin y operacin English PARTS INCLUDED:
Remote Button Control Box Battery Box 3/8" x 1/4" Tube Adapter Mounting Screws Air Gap SPECIFICATIONS Pressure Range:
Temperature Range:
30 120 psi (207827 kPa) 40 100F (4.4 37.7C) TOOLS & MATERIALS REQUIRED C Batteries x4 AAA Batteries x2 Screwdriver Adjustable Wrench Towels Pan or Bucket PRECAUTIONS WARNING: Follow all precautions indicated in the manual provided with the Culligan water treatment system. WARNING: For systems using a booster or distribution pump, the pressure of the treated water cannot exceed the pressure of the cold water supply. CAUTION: Control box must be protected against freezing temperatures, frost, snow, sleet, and ice. Exposure to these can produce cracks and product failures. CAUTION: This product has a limited service life. We recommend that a record be kept regarding the date of install and any other performed maintenance. Because of the products limited service life and to prevent costly repairs or possible water damage, we strongly recommend that the control box be replaced every ten years. WARNING: For cold water use only. Do not use on hot water line. After prolonged periods of non-use (such as during a vacation) it is recommended that the system be flushed thoroughly. Let the filtered water run for 56 minutes before using. The ClearLink estimates filter life based on flow and time. Changes in taste, odor, color, and/or flow of the filtered water could indicate that the filter(s) should be replaced. Make certain that installation complies with all state and local laws and regulations. 2 UNIVERSAL WIRELESS FILTRATION CONTROL PARTS INCLUDED:
Remote Button Button Part No.: 01029450 Trim Ring Part Nos.:
Chrome 01029452 Brushed Nickel 01029453 Oil Rubbed Bronze 01029454 Control Box Part No.: 01029449 Battery Box Part No.: 01029451 3/8" x 1/4" Tube Adapter Mounting Screws Air Gap 3 SETTING CAPACITY AND TDS FUNCTION NOTE: Set capacity and TDS function before starting installation. NOTE: To access the dip switches for setting capacity and TDS function, open the control box by removing the three screws in the rear cover. Find the dip switches on the front of the circuit board. SW2 and SW3 set the time and capacity for the filter reminder. ON SW2: OFF = 500 gallons SW3: OFF = 180 days ON = 1000 gallons ON = 365 days SW1 Enables/Disables the TDS function (Enable only for RO systems). The system will measure the difference between the feed and product water to determine if the RO is working. SW1: OFF = Disabled SW6 is used for production testing and should be left in the off position. ON = Enabled S W 1 S W 2 S W 3 S W 6 INSTALLATION NOTE: Refer to the manual provided with your filter/RO for installation instructions specific to that system. NOTE: Some installations may require adapters and fittings not included with the product. Review the manual and your installation before beginning. NOTE: Consult your local plumbing codes and install accordingly. Turn off cold water shut-off valve then turn on the kitchen faucet and allow all water to drain from line. Disconnect the cold water line from the cold water shut-off valve. NOTE: If rigid plumbing pipe (metal or plastic) is used, you may need to shorten the pipe using a hacksaw or pipe cutter to accommodate the control box. 4 Tighten the control box to the cold water shut-off valve as shown. Tighten the lower end of cold water line onto the top of the control box. NOTE: The control box must be in a vertical position. NOTE: If space does not allow for mounting the control box onto the valve, it can be alternatively hung on a wall when using the holes on the back and a flex connection (purchased separately). Connect the inlet on the RO/Filter system to the port marked "RO/Filter >." Wet the end of the plastic tubing with water and push it into the quick connect fitting adapter approximately 5/8 until it stops. NOTE: This connection is plugged for remote system installations (Water supply is not the same as the sink such as basement installations). NOTE: This is the line that would normally come from the supply tee or valve. NOTE: Use the supplied adapter if your system uses a 1/4" tube. Connect the outlet on the RO/Filter system to the port marked "RO/Filter <." Wet the end of the plastic tubing with water and push it into the quick connect fitting adapter approximately 5/8"
until it stops. NOTE: This is the line that would normally go to your dedicated faucet. NOTE: Connect the tank and/or post filter in this line if required for your filter/RO system. 5 RO AIR GAP INSTALLATION NOTE: These steps are only for RO installations using an air gap. NOTE:
NOTE: Install the drain connection to the drain plumbing according to the manual If your filtration system is not an RO, skip to System Startup on Page 7. provided with your RO system. AIR GAP Mount the air gap device as near to counter top as possible and in a vertical orientation. NOTE: Failure to mount the air gap device vertically will cause it to leak water. Connect the drain line coming from the RO system to the small connection of the air gap device. Connect the large fitting of the air gap device to the connection on the drain plumbing. 6 SYSTEM STARTUP BYPASS Confirm that the bypass valve is in the closed position (pointed down). Turn on the cold water supply and check for leaks. If it leaks, refer to troubleshooting. Install four C batteries (not included) into the battery box and plug into the jack on the bottom of the control box. NOTE: The control box will beep and flash the power light when powering up. NOTE: AC adapter (01029455) can also be used where a non-switched outlet is available. 7 Use the provided screw to hang the battery box on the side of the cabinet. SYSTEM STARTUP Install two AAA batteries (not included) into the remote button. Turn on the faucet to full cold and push the button to activate the system. NOTE: The blue capacity lights should appear if the button and control box are communicating. NOTE: The button can be turned off with a second push or by turning off the faucet. NOTE: After startup, flush your system according to manufacturer's specifications. It might take a few cycles for the button to stay on while air is purged from the system. 8 BUTTON DISPLAY GUIDE CONTROL BOX OPERATION RESET POWER REPLACE BATTERIES REPLACE FILTERS REPLACE RO MEMBRANE Filter Capacity Lights: Shows from 1-6 lights depending on filter capacity remaining, 6 lights = >80% and 1 light = <10%. Culligan Logo: Flashes when treated water is not available from the faucet. Stays solid while treated water is being dispensed from the faucet. Alert Indicator: Illuminates when the control box batteries need replacing, filters need replacing, or RO membrane needs replacing. Reset button for filter capacity. Power: Flashes green at power up, filter capacity reset, and while dispensing filtered water. Continues to flash for 1 minute after the flow of filtered water has stopped. Replace Batteries: Flashes red when the batteries for the control box need to be replaced. This indicator automatically clears when new batteries are detected. Replace Filters: Flashes red when the filters have less than 10% of their life remaining due to flow or time. This indicator is reset by pressing the reset button for two seconds. Replace RO Membrane: Flashes red when the treated water has a TDS level greater than 25% of the untreated water. This indicator will automatically reset when low TDS water is detected. 9 TROUBLESHOOTING LEAKS AT FILTER/RO INLET OR OUTLET CONNECTION:
A rolled o-ring can block the tube from fully inserting. Use small screw driver to re-seat the o-ring and then confirm that the end of the tubing has a clean, square cut. LOW FILTERED WATER FLOW/SYSTEM RETURNS TO UNFILTERED FLOW AUTOMATICALLY:
Low flow rates may not activate the control box electronics. Refer to your system manual to trouble shoot a low flow condition. BUTTON IS COMMUNICATING BUT NO CHANGE IN FLOW:
Confirm that the bypass valve is in the down/closed position. BUTTON COMMUNICATION IS INTERMITTENT:
Some materials may block the wireless signal more than others. Try moving the button to an area on the counter that is closer to the under-sink control box. FILTERED WATER FLOW WON'T TURN OFF: Low batteries for the control box can cause the system to be stuck in the filtered position. The bypass valve can be used to allow unfiltered water flow to the faucet while the issue is being corrected. THE CLEARLINK PRO IS CERTIFIED BY WQA AGAINST CSA B483.1, NSF/ANSI 372 FOR LOW LEAD REQUIREMENT, NSF/ANSI 42 AND NSF/ANSI 58 FOR MATERIAL SAFETY AND STRUCTURAL INTEGRITY 10 ONE-YEAR LIMITED WARRANTY This warranty applies to the button, control box and battery box. This warranty covers defects in material and workmanship only for 1 full year from the original date of delivery. Culligan will replace any part which in Culligans opinion is defective, unless: (1) any part of the unit has been subjected to any type of tampering, alteration, or improper use after delivery, or (2) it has been repaired by anyone not approved by Culligan. This product has been designed solely for use as a water filtration control. It is NOT warranted against freezing or surges in water pressure, and neither this product nor its parts is warranted against defects or deterioration caused by uses for which this product was not expressly intended. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, WHETHER ORAL OR ARISING BY USAGE OF TRADE OR COURSE OF DEALING, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF FITNESS OR MERCHANTABILITY. THIS WARRANTY IS THE PURCHASERS SOLE AND EXCLUSIVE REMEDY, IN NO EVENT SHALL CULLIGAN BE LIABLE FOR ANY ANTICIPATED OR LOST PROFITS, INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, COSTS, TIME CHARGES OR OTHER LOSSES, WHETHER BASED ON BREACH OF CONTRACT, TORTIOUS CONDUCT OR ANY OTHER THEORY, INCURRED IN CONNECTION WITH THE PURCHASE, INSTALLATION, REPAIR OR OPERATION OF THIS PRODUCT. CULLIGAN DOES NOT AUTHORIZE ANYONE TO ASSUME FOR IT ANY LIABILITY OR TO MAKE ON ITS BEHALF ANY ADDITIONAL WARRANTIES IN CONNECTION WITH THE FILTER HOUSING OR ANY PART THEREOF. Model: CulRF-M used in devices ClearLink PB and ClearLink D Contains the FCC ID: V7U-010291CL and IC: 6510B-010291CL This device complies with part 15 of the FCC Rules subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept all interference received including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil nedoit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. This device complies with Health Canadas Safety Code. The installer of this device should ensure that RF radiation is not emitted in excess of the Health Canadas requirement. Cet appareil est conforme avec Sant Canada Code de scurit 6. Le programme dinstallation de cet appareil doit sassurer que les rayonnements RF nest pas mis au-del de Iexigence de Sant Canada. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Les changements ou modifications non expressment approuvs par la partie responsable de la conformit pourraient annuler l'autorit de l'utilisateur utiliser cet quipement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. 11 Espaol PIEZAS INCLUIDO Botn del Control Remoto Caja de Control Caja de Batera Adaptadore 3/8" x 1/4"
Tornillos de Montaje Entrehierro HERRAMIENTAS Y MATERIALES REQUERIDOS Bateras C x4 Bateras AAA x2 Destornillador Llave Ajustable Toallas Bandeja o Cubeta ESPECIFICACIONES Gama de Presin:
Gama de Temperatura:
30 120 psi (207827 kPa) 40 100F (4.4 37.7C) PRECAUCIONES ADVERTENCIA: Siga todas las precauciones indicadas en el manual provisto con el sistema de tratamiento de agua de Culligan. ADVERTENCIA: Para sistemas empleando una bomba de refuerzo o de distribucin, la presin del agua no tratado no puede exceder la presin del agua fra del suministro. PRECAUCIN: Se exige que la caja de control sea protegida de temperaturas bajo cero, escarcha, nieve, aguanieve, y hielo. El producto puede fallar si se expone a estos elementos. PRECAUCIN: Este producto lleva una vida de servicio limitada. Se recomienda que se lleve un registro de la instalacin y de cualquier otro mantenimiento. Debido a la vida de servicio limitada, y para evitar reparaciones costosas o posibles daos por agua, se recomienda enfticamente que la caja de control sea reemplazada cada diez aos. ADVERTENCIA: Se debe utilizar nicamente con agua fra. No se debe utilizar con agua caliente. Despus de periodos extendidos sin uso (p. ej. durante vacaciones) es aconsejable enjuagar el sistema dejando correr el agua por 5-6 minutos antes de usarlo. El ClearLink mide la vida de un filtro segn el nivel de flujo y el tiempo. Cambios en el sabor, olor, color, y/o el flujo de agua filtrada podra indicar que el filtro debe ser reemplazado. Asegrese de que la instalacin cumpla con todas las leyes y regulaciones locales y estatales. 12 CONTROL DE FILTRACIN INALMBRICO UNIVERSAL PIEZAS INCLUIDAS:
Botn del Control Remoto Botn Nm.: 01029450 Opciones de Anillo de Borde:
Cromo 01029452 Nquel Cepillado 01029453 Bronce de Aceite Frotado 01029454 Caja de Control Parte Nm.: 01029449 Caja de Batera Parte Nm.: 01029451 Adaptadore de Tubo 3/8" x 1/4"
Tornillos de Montaje Entrehierro 13 PROGRAMAR LA CAPACIDAD Y LA FUNCIN TDS NOTA: Favor de programar la capacidad y la funcin TDS antes de comenzar la instalacin. NOTA: Para obtener acceso a los interruptores DIP para la capacidad y la funcin TDS, abra la caja de control por medio de retirar los tres tornillos de la cubierta trasera. Localice los interruptores DIP en la parte frontal de la placa de circuito. SW2 y SW3 fijan el tiempo y la capacidad para el recordatorio de cambio de filtro. SW2: APAGADO = 500 galones SW3: APAGADO = 180 das ENCENDIDO = 1,000 galones ENCENDIDO = 365 das ON SW1: Habilita/Inhabilita la funcin TDS (Habilita slamente para sistemas de Osmosis Inverso). S W 1 S W 2 S W 3 S W 6 ENCENDIDO = Habilitado SW1: APAGADO = Inhabilitado SW6 se usa para las pruebas de produccin y debe permanecer en la posicin apagada. INSTALACIN NOTA: Favor de referirse al manual provisto con su filtro/sistema de osmosis inverso para las instrucciones de instalacin especificadas para s sistema de filtracin. NOTA: Algunas instalaciones exigen adaptadores u otras piezas no incluidas con este producto. Repase el manual y el proceso de instalacin antes de comenzar. NOTA: Consulte y instale de acuerdo con los cdigos de plomera locales. 1 Desconecte la lnea de suministro de agua fra, despus abra el grifo de la cocina y deje que drene toda el agua de la caera. Desconecte la lnea de agua fra de la vlvula de cierre de agua fra. NOTA: Si utiliza tubera rgida (de metal o plstico), es posible que deba acortar la tubera con una sierra para metales o un cortatubos a fin de hacer espacio para la caja de control. 14 Aprieta la caja de control a la vlvula de cierre de agua fra segn la diagrama. Aprieta la parte inferior de la lnea de agua fra a la parte superior de la caja de control. NOTA: Se exige que la caja de control se instale verticalmente. NOTA: La caja de control puede ser colgada en una pared usando conectadores flexibles como una alternativa. Conecte la entrada del sistema de filtracin al puerto titulado "RO/Filter>" de la caja de control. Moje el extremo del tubo de plstico con agua y empjelo en el adaptador de conexin rpido aproximadamente 5/8" hasta que pare. NOTA: Esta conexin est conectado para instalaciones de sistemas remotos (El suministro de agua para el filtro no es el mismo suministro de agua para el fregadero). NOTA: Esta es la lnea que normalmente correra desde la la vlvula de suministro de agua. NOTA: Use uno de los adaptadore suministrados si su sistema emplea un tubo ms pequeo. Conecte la salida del sistema de filtracin al puerto titulado "RO/Filter<" de la caja de control. Moje el extremo del tubo de plstico con agua y empjelo en el adaptador de conexin rpido aproximadamente 5/8" hasta que pare. NOTA: Esta es la lnea que normalmente correra hacia el grifo dedicado. NOTA: Use uno de los adaptadore suministrados si su sistema emplea un tubo ms pequeo. 15 empleando un entrehierro. INSTALACIN DE ENTREHIERRO PARA OSMOSIS INVERSO NOTA: Los siguientes pasos aplican nicamente a instalaciones de osmosis inverso NOTA: Si su sistema de filtracin no es de osmosis inverso, brinque a la seccin de NOTA: Instale el conectador de drenaje al drenaje de acuerdo con el manual provisto con s sistema de osmosis inverso. Inicio del Sistema en la pgina 7. ENTREHIERRO Monte el entrehierro en la posicin vertical lo ms cerca posible a la encimera. NOTA: El entrehierro derramar agua si no se instala verticalmente. Conecte la lnea de drenaje saliendo del sistema de osmosis inverso a la pequea conexin pa del entrehierro. Conecte la pa grande del entrehierro a la conexin de drenaje. 16 INICIO DEL SISTEMA BYPASS Asegrese que la vlvula de derivacin est en la posicin cerrada (apuntada hacia abajo). Abra el suministro de agua fra para averiguar si se derrama agua o no. Si el sistema est derramando agua, consulte la seccin de Solucin de Problemas. Use el tornillo provisto para colgar la caja de bateras a la pared interior del cabinete. Instale cuatro bateras C (no incluidas) en la caja de pilas y enchufe al gato en la parte inferior de la caja de control. NOTA: La caja de control emitir un pitido y la luz de fuerza parpadear al encender. NOTA: El adaptador AC (01029455) puede usarse tambin cuando un enchufe no interruptor est disponible. 17 INICIO DEL SISTEMA Instale dos bateras AAA (no incluidas) en el botn de control remoto. Abra el grifo de agua fra completamente y empuja el botn para activar el sistema. NOTA: La luces azules de capacidad deben encenderse si el botn y la caja de control estn comunicndose. NOTA: El botn se puede apagar con un segundo empujn o apagando el grifo. NOTA: Despus del inicio, enjuague el sistema de acuerdo con las especificaciones del fabricante. Puede que tome algunos ciclos para que el botn permanezca encendido mientras aire sea expulsado del sistema. 18 GUA DE LA PANTALLA DEL BOTN Luces de Capacidad del Filtro: Ensean 1-6 luces dependiendo de la capacidad del filtro que le quede, 6 luces = >80% y 1 luz = <10%. Logo Culligan: Enciende cuando agua filtrada no est disponible desde el grifo. Permanece encendido mientras agua filtrada corra desde el grifo. Alarma: Enciende cuando las bateras de la caja de control, los filtros, o la membrana de osmosis inverso deben ser reemplazados. OPERACIN DE LA CAJA DE CONTROL RESET POWER REPLACE BATTERIES REPLACE FILTERS REPLACE RO MEMBRANE Botn de reinicio de capacidad del filtro. Fuerza: Enciende de color verde al inicio, cuando reinicia la capacidad del filtro, y mientras corra agua filtrada. La luz parpadear por 1 minuto despus de que se cierre el flujo de agua. Reemplazo de Bateras: Enciende de color rojo cuando las bateras para la caja de control deben ser reemplazadas. Reemplazo de Filtros: Enciende de color rojo cuando los filtros tienen menos de 10% de vida segn indica el flujo o el tiempo. Este indicador se reinicia empujando el botn de reinicio por dos segundos. Reemplazo de Membrana de Osmosis Inverso:
Enciende de color rojo cuando el agua filtrada tiene un nivel de TDS mayor de 25% del agua no filtrada. Este indicador se reinicia automaticamente cuando se detecta TDS bajo en el agua. 19 SOLUCIN DE PROBLEMAS FUGAS DE AGUA POR ENTRADA O SALIDA DEL FILTRO/SISTEMA DE OSMOSIS INVERSO:
Una arendala doblada podra estorbar en entrada completa del tubo. Use un destornillador pequeo para asentar la arendala de nuevo, y entonces asegurarse de que el extremo del tubo tenga una cortada cuadrada, y limpia. FLUJO BAJO DE AGUA FILTRADA/EL SISTEMA CAMBIA DE AGUA FILTRADA A AGUA NO FILTRADA AUTOMATICAMENTE:
El flujo bajo quiz no este activando la caja de control. Consulte el manual de su sistema de filtracin para averiguar cmo aumentar el flujo de agua. EL BOTN COMUNICA PERO NO HAY CAMBIO EN EL FLUJO:
Confirme que la vlvula de derivacin est en la posicin cerrada/apuntada hacia abajo. EL BOTN NO COMUNICA SIEMPRE:
Algunos materiales pueden estorbar la seal inalmbrica mas que otros. Puede probar la seal moviendo el botn a otra area ubicada ms de cerca a la caja de control. EL AGUA FILTRADA NO SE APAGA: Bateras de poca fuerza en la caja de control pueden causar que el sistema se quede en la posicin de agua filtrada. Se puede emplear la vlvula de derivacin para permitir el flujo de agua no filtrada al grifo mientras se corrija el asunto. LAS CLEARLINK PRO HA SIDO CERTIFICADOS POR LA WQA SEGN LAS NORMAS CSA B483.1, NSF/
ANSI 372 PARA EL REQUISITO DE PLOMO BAJO, NSF/ANSI 42 Y NSF/ANSI 58 PARA LA SEGURIDAD DE LOS MATERIALES Y LA INTEGRIDAD ESTRUCTURAL 20 GARANTA LIMITADA DE UN AO La garanta se aplica al botn y la caja de batera. La garanta cubre los defectos en el material y la fabricacin por un ao completo desde la fecha original de entrega. Culligan reemplazar cualquier pieza que se considere defectuosa, con las siguientes excepciones: (1) si algn componente de la unidad estuvo sujeto a algn tipo de manipulacin, alteracin o uso inapropiado despus de la entrega, o (2) si haba sido reparado por una agencia no aprobada por Culligan. Este producto ha sido diseado solamente para ser usado como un control de filtracin de agua. La garanta NO cubre daos producidos debido a las temperaturas bajo cero o el aumento repentino de presin de agua. El uso indebido de este producto y sus componentes podra provocar defectos o deterioro no estn cubiertos por la garanta. LA GARANTA SUSODICHA ES EXCLUSIVA Y SUSTITUYE CUALQUIER OTRA GARANTA, EXPRESA O IMPLCITA, YA SEA UNA GARANTA VERBAL O UNA QUE DERIVE DEL USO O LA PRCTICA COMERCIAL, INCLUIDA, DE MANERA SIN LMITE, CUALQUIER GARANTA DE APTITUD O COMERCIABILIDAD. ESTA GARANTA ES EL NICO RECURSO EXCLUSIVO DEL COMPRADOR. BAJO NINGUNA CIRCUNSTANCIA CULLIGAN ASUMIR LA RESPONSABILIDAD POR LA PRDIDA DE GANANCIAS ANTICIPADAS, LOS DAOS ACCIDENTALES, DAOS CONSECUENTES, GASTOS, GASTOS DE TIEMPO DE MANO DE OBRA U OTRO TIPO DE PRDIDAS, SEA POR EL INCUMPLIMIENTO DEL CONTRATO, UNA CONDUCTA ILCITA O CUALQUIER OTRA TEORA, EN RELACIN CON LA COMPRA, LA INSTALACIN, LA REPARACIN O EL FUNCIONAMIENTO DE ESTE PRODUCTO. CULLIGAN NO AUTORIZA A NINGUNA PERSONA A ASUMIR RESPONSABILIDADES U OTORGAR GARANTAS ADICIONALES EN SU NOMBRE EN RELACIN CON ESTE PRODUCTO. 21 Culligan International Company Rosemont, Illinois 60018 www.culligan.com 847-430-2800 2015 Culligan International Company 01029457 B DRINKING WATER | AGUA POTABLE ClearLink Pro Wireless Filtration Control Installation and operating instructions ClearLink Pro Control de Filtracin de Agua Inalmbrico Instrucciones de instalacin y operacin English PARTS INCLUDED:
Remote Button Control Box Battery Box 3/8" x 1/4" Tube Adapter Mounting Screws Air Gap SPECIFICATIONS Pressure Range:
Temperature Range:
30 120 psi (207827 kPa) 40 100F (4.4 37.7C) TOOLS & MATERIALS REQUIRED C Batteries x4 AAA Batteries x2 Screwdriver Adjustable Wrench Towels Pan or Bucket PRECAUTIONS WARNING: Follow all precautions indicated in the manual provided with the Culligan water treatment system. WARNING: For systems using a booster or distribution pump, the pressure of the treated water cannot exceed the pressure of the cold water supply. CAUTION: Control box must be protected against freezing temperatures, frost, snow, sleet, and ice. Exposure to these can produce cracks and product failures. CAUTION: This product has a limited service life. We recommend that a record be kept regarding the date of install and any other performed maintenance. Because of the products limited service life and to prevent costly repairs or possible water damage, we strongly recommend that the control box be replaced every ten years. WARNING: For cold water use only. Do not use on hot water line. After prolonged periods of non-use (such as during a vacation) it is recommended that the system be flushed thoroughly. Let the filtered water run for 56 minutes before using. The ClearLink estimates filter life based on flow and time. Changes in taste, odor, color, and/or flow of the filtered water could indicate that the filter(s) should be replaced. Make certain that installation complies with all state and local laws and regulations. 2 UNIVERSAL WIRELESS FILTRATION CONTROL PARTS INCLUDED:
Remote Button Button Part No.: 01029450 Trim Ring Part Nos.:
Chrome 01029452 Brushed Nickel 01029453 Oil Rubbed Bronze 01029454 Control Box Part No.: 01029449 Battery Box Part No.: 01029451 3/8" x 1/4" Tube Adapter Mounting Screws Air Gap 3 SETTING CAPACITY AND TDS FUNCTION NOTE: Set capacity and TDS function before starting installation. NOTE: To access the dip switches for setting capacity and TDS function, open the control box by removing the three screws in the rear cover. Find the dip switches on the front of the circuit board. SW2 and SW3 set the time and capacity for the filter reminder. ON SW2: OFF = 500 gallons SW3: OFF = 180 days ON = 1000 gallons ON = 365 days SW1 Enables/Disables the TDS function (Enable only for RO systems). The system will measure the difference between the feed and product water to determine if the RO is working. SW1: OFF = Disabled SW6 is used for production testing and should be left in the off position. ON = Enabled S W 1 S W 2 S W 3 S W 6 INSTALLATION NOTE: Refer to the manual provided with your filter/RO for installation instructions specific to that system. NOTE: Some installations may require adapters and fittings not included with the product. Review the manual and your installation before beginning. NOTE: Consult your local plumbing codes and install accordingly. Turn off cold water shut-off valve then turn on the kitchen faucet and allow all water to drain from line. Disconnect the cold water line from the cold water shut-off valve. NOTE: If rigid plumbing pipe (metal or plastic) is used, you may need to shorten the pipe using a hacksaw or pipe cutter to accommodate the control box. 4 Tighten the control box to the cold water shut-off valve as shown. Tighten the lower end of cold water line onto the top of the control box. NOTE: The control box must be in a vertical position. NOTE: If space does not allow for mounting the control box onto the valve, it can be alternatively hung on a wall when using the holes on the back and a flex connection (purchased separately). Connect the inlet on the RO/Filter system to the port marked "RO/Filter >." Wet the end of the plastic tubing with water and push it into the quick connect fitting adapter approximately 5/8 until it stops. NOTE: This connection is plugged for remote system installations (Water supply is not the same as the sink such as basement installations). NOTE: This is the line that would normally come from the supply tee or valve. NOTE: Use the supplied adapter if your system uses a 1/4" tube. Connect the outlet on the RO/Filter system to the port marked "RO/Filter <." Wet the end of the plastic tubing with water and push it into the quick connect fitting adapter approximately 5/8"
until it stops. NOTE: This is the line that would normally go to your dedicated faucet. NOTE: Connect the tank and/or post filter in this line if required for your filter/RO system. 5 RO AIR GAP INSTALLATION NOTE: These steps are only for RO installations using an air gap. NOTE:
NOTE: Install the drain connection to the drain plumbing according to the manual If your filtration system is not an RO, skip to System Startup on Page 7. provided with your RO system. AIR GAP Mount the air gap device as near to counter top as possible and in a vertical orientation. NOTE: Failure to mount the air gap device vertically will cause it to leak water. Connect the drain line coming from the RO system to the small connection of the air gap device. Connect the large fitting of the air gap device to the connection on the drain plumbing. 6 SYSTEM STARTUP BYPASS Confirm that the bypass valve is in the closed position (pointed down). Turn on the cold water supply and check for leaks. If it leaks, refer to troubleshooting. Install four C batteries (not included) into the battery box and plug into the jack on the bottom of the control box. NOTE: The control box will beep and flash the power light when powering up. NOTE: AC adapter (01029455) can also be used where a non-switched outlet is available. 7 Use the provided screw to hang the battery box on the side of the cabinet. SYSTEM STARTUP Install two AAA batteries (not included) into the remote button. Turn on the faucet to full cold and push the button to activate the system. NOTE: The blue capacity lights should appear if the button and control box are communicating. NOTE: The button can be turned off with a second push or by turning off the faucet. NOTE: After startup, flush your system according to manufacturer's specifications. It might take a few cycles for the button to stay on while air is purged from the system. 8 BUTTON DISPLAY GUIDE CONTROL BOX OPERATION RESET POWER REPLACE BATTERIES REPLACE FILTERS REPLACE RO MEMBRANE Filter Capacity Lights: Shows from 1-6 lights depending on filter capacity remaining, 6 lights = >80% and 1 light = <10%. Culligan Logo: Flashes when treated water is not available from the faucet. Stays solid while treated water is being dispensed from the faucet. Alert Indicator: Illuminates when the control box batteries need replacing, filters need replacing, or RO membrane needs replacing. Reset button for filter capacity. Power: Flashes green at power up, filter capacity reset, and while dispensing filtered water. Continues to flash for 1 minute after the flow of filtered water has stopped. Replace Batteries: Flashes red when the batteries for the control box need to be replaced. This indicator automatically clears when new batteries are detected. Replace Filters: Flashes red when the filters have less than 10% of their life remaining due to flow or time. This indicator is reset by pressing the reset button for two seconds. Replace RO Membrane: Flashes red when the treated water has a TDS level greater than 25% of the untreated water. This indicator will automatically reset when low TDS water is detected. 9 TROUBLESHOOTING LEAKS AT FILTER/RO INLET OR OUTLET CONNECTION:
A rolled o-ring can block the tube from fully inserting. Use small screw driver to re-seat the o-ring and then confirm that the end of the tubing has a clean, square cut. LOW FILTERED WATER FLOW/SYSTEM RETURNS TO UNFILTERED FLOW AUTOMATICALLY:
Low flow rates may not activate the control box electronics. Refer to your system manual to trouble shoot a low flow condition. BUTTON IS COMMUNICATING BUT NO CHANGE IN FLOW:
Confirm that the bypass valve is in the down/closed position. BUTTON COMMUNICATION IS INTERMITTENT:
Some materials may block the wireless signal more than others. Try moving the button to an area on the counter that is closer to the under-sink control box. FILTERED WATER FLOW WON'T TURN OFF: Low batteries for the control box can cause the system to be stuck in the filtered position. The bypass valve can be used to allow unfiltered water flow to the faucet while the issue is being corrected. Model: CulRF-M used in devices ClearLink PB and ClearLink D Contains the FCC ID: V7U-010291CL and IC: 6510B-010291CL This device complies with part 15 of the FCC Rules subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept all interference received including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil nedoit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. This device complies with Health Canadas Safety Code. The installer of this device should ensure that RF radiation is not emitted in excess of the Health Canadas requirement. Cet appareil est conforme avec Sant Canada Code de scurit 6. Le programme dinstallation de cet appareil doit sassurer que les rayonnements RF nest pas mis au-del de Iexigence de Sant Canada. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Les changements ou modifications non expressment approuvs par la partie responsable de la conformit pourraient annuler l'autorit de l'utilisateur utiliser cet quipement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. 10 ONE-YEAR LIMITED WARRANTY This warranty applies to the button, control box and battery box. This warranty covers defects in material and workmanship only for 1 full year from the original date of delivery. Culligan will replace any part which in Culligans opinion is defective, unless: (1) any part of the unit has been subjected to any type of tampering, alteration, or improper use after delivery, or (2) it has been repaired by anyone not approved by Culligan. This product has been designed solely for use as a water filtration control. It is NOT warranted against freezing or surges in water pressure, and neither this product nor its parts is warranted against defects or deterioration caused by uses for which this product was not expressly intended. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, WHETHER ORAL OR ARISING BY USAGE OF TRADE OR COURSE OF DEALING, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF FITNESS OR MERCHANTABILITY. THIS WARRANTY IS THE PURCHASERS SOLE AND EXCLUSIVE REMEDY, IN NO EVENT SHALL CULLIGAN BE LIABLE FOR ANY ANTICIPATED OR LOST PROFITS, INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, COSTS, TIME CHARGES OR OTHER LOSSES, WHETHER BASED ON BREACH OF CONTRACT, TORTIOUS CONDUCT OR ANY OTHER THEORY, INCURRED IN CONNECTION WITH THE PURCHASE, INSTALLATION, REPAIR OR OPERATION OF THIS PRODUCT. CULLIGAN DOES NOT AUTHORIZE ANYONE TO ASSUME FOR IT ANY LIABILITY OR TO MAKE ON ITS BEHALF ANY ADDITIONAL WARRANTIES IN CONNECTION WITH THE FILTER HOUSING OR ANY PART THEREOF. 11 Espaol PIEZAS INCLUIDO Botn del Control Remoto Caja de Control Caja de Batera Adaptadore 3/8" x 1/4"
Tornillos de Montaje Entrehierro HERRAMIENTAS Y MATERIALES REQUERIDOS Bateras C x4 Bateras AAA x2 Destornillador Llave Ajustable Toallas Bandeja o Cubeta ESPECIFICACIONES Gama de Presin:
Gama de Temperatura:
30 120 psi (207827 kPa) 40 100F (4.4 37.7C) PRECAUCIONES ADVERTENCIA: Siga todas las precauciones indicadas en el manual provisto con el sistema de tratamiento de agua de Culligan. ADVERTENCIA: Para sistemas empleando una bomba de refuerzo o de distribucin, la presin del agua no tratado no puede exceder la presin del agua fra del suministro. PRECAUCIN: Se exige que la caja de control sea protegida de temperaturas bajo cero, escarcha, nieve, aguanieve, y hielo. El producto puede fallar si se expone a estos elementos. PRECAUCIN: Este producto lleva una vida de servicio limitada. Se recomienda que se lleve un registro de la instalacin y de cualquier otro mantenimiento. Debido a la vida de servicio limitada, y para evitar reparaciones costosas o posibles daos por agua, se recomienda enfticamente que la caja de control sea reemplazada cada diez aos. ADVERTENCIA: Se debe utilizar nicamente con agua fra. No se debe utilizar con agua caliente. Despus de periodos extendidos sin uso (p. ej. durante vacaciones) es aconsejable enjuagar el sistema dejando correr el agua por 5-6 minutos antes de usarlo. El ClearLink mide la vida de un filtro segn el nivel de flujo y el tiempo. Cambios en el sabor, olor, color, y/o el flujo de agua filtrada podra indicar que el filtro debe ser reemplazado. Asegrese de que la instalacin cumpla con todas las leyes y regulaciones locales y estatales. 12 CONTROL DE FILTRACIN INALMBRICO UNIVERSAL PIEZAS INCLUIDAS:
Botn del Control Remoto Botn Nm.: 01029450 Opciones de Anillo de Borde:
Cromo 01029452 Nquel Cepillado 01029453 Bronce de Aceite Frotado 01029454 Caja de Control Parte Nm.: 01029449 Caja de Batera Parte Nm.: 01029451 Adaptadore de Tubo 3/8" x 1/4"
Tornillos de Montaje Entrehierro 13 PROGRAMAR LA CAPACIDAD Y LA FUNCIN TDS NOTA: Favor de programar la capacidad y la funcin TDS antes de comenzar la instalacin. NOTA: Para obtener acceso a los interruptores DIP para la capacidad y la funcin TDS, abra la caja de control por medio de retirar los tres tornillos de la cubierta trasera. Localice los interruptores DIP en la parte frontal de la placa de circuito. SW2 y SW3 fijan el tiempo y la capacidad para el recordatorio de cambio de filtro. SW2: APAGADO = 500 galones SW3: APAGADO = 180 das ENCENDIDO = 1,000 galones ENCENDIDO = 365 das ON SW1: Habilita/Inhabilita la funcin TDS (Habilita slamente para sistemas de Osmosis Inverso). S W 1 S W 2 S W 3 S W 6 ENCENDIDO = Habilitado SW1: APAGADO = Inhabilitado SW6 se usa para las pruebas de produccin y debe permanecer en la posicin apagada. INSTALACIN NOTA: Favor de referirse al manual provisto con su filtro/sistema de osmosis inverso para las instrucciones de instalacin especificadas para s sistema de filtracin. NOTA: Algunas instalaciones exigen adaptadores u otras piezas no incluidas con este producto. Repase el manual y el proceso de instalacin antes de comenzar. NOTA: Consulte y instale de acuerdo con los cdigos de plomera locales. 1 Desconecte la lnea de suministro de agua fra, despus abra el grifo de la cocina y deje que drene toda el agua de la caera. Desconecte la lnea de agua fra de la vlvula de cierre de agua fra. NOTA: Si utiliza tubera rgida (de metal o plstico), es posible que deba acortar la tubera con una sierra para metales o un cortatubos a fin de hacer espacio para la caja de control. 14 Aprieta la caja de control a la vlvula de cierre de agua fra segn la diagrama. Aprieta la parte inferior de la lnea de agua fra a la parte superior de la caja de control. NOTA: Se exige que la caja de control se instale verticalmente. NOTA: La caja de control puede ser colgada en una pared usando conectadores flexibles como una alternativa. Conecte la entrada del sistema de filtracin al puerto titulado "RO/Filter>" de la caja de control. Moje el extremo del tubo de plstico con agua y empjelo en el adaptador de conexin rpido aproximadamente 5/8" hasta que pare. NOTA: Esta conexin est conectado para instalaciones de sistemas remotos (El suministro de agua para el filtro no es el mismo suministro de agua para el fregadero). NOTA: Esta es la lnea que normalmente correra desde la la vlvula de suministro de agua. NOTA: Use uno de los adaptadore suministrados si su sistema emplea un tubo ms pequeo. Conecte la salida del sistema de filtracin al puerto titulado "RO/Filter<" de la caja de control. Moje el extremo del tubo de plstico con agua y empjelo en el adaptador de conexin rpido aproximadamente 5/8" hasta que pare. NOTA: Esta es la lnea que normalmente correra hacia el grifo dedicado. NOTA: Use uno de los adaptadore suministrados si su sistema emplea un tubo ms pequeo. 15 empleando un entrehierro. INSTALACIN DE ENTREHIERRO PARA OSMOSIS INVERSO NOTA: Los siguientes pasos aplican nicamente a instalaciones de osmosis inverso NOTA: Si su sistema de filtracin no es de osmosis inverso, brinque a la seccin de NOTA: Instale el conectador de drenaje al drenaje de acuerdo con el manual provisto con s sistema de osmosis inverso. Inicio del Sistema en la pgina 7. ENTREHIERRO Monte el entrehierro en la posicin vertical lo ms cerca posible a la encimera. NOTA: El entrehierro derramar agua si no se instala verticalmente. Conecte la lnea de drenaje saliendo del sistema de osmosis inverso a la pequea conexin pa del entrehierro. Conecte la pa grande del entrehierro a la conexin de drenaje. 16 INICIO DEL SISTEMA BYPASS Asegrese que la vlvula de derivacin est en la posicin cerrada (apuntada hacia abajo). Abra el suministro de agua fra para averiguar si se derrama agua o no. Si el sistema est derramando agua, consulte la seccin de Solucin de Problemas. Use el tornillo provisto para colgar la caja de bateras a la pared interior del cabinete. Instale cuatro bateras C (no incluidas) en la caja de pilas y enchufe al gato en la parte inferior de la caja de control. NOTA: La caja de control emitir un pitido y la luz de fuerza parpadear al encender. NOTA: El adaptador AC (01029455) puede usarse tambin cuando un enchufe no interruptor est disponible. 17 INICIO DEL SISTEMA Instale dos bateras AAA (no incluidas) en el botn de control remoto. Abra el grifo de agua fra completamente y empuja el botn para activar el sistema. NOTA: La luces azules de capacidad deben encenderse si el botn y la caja de control estn comunicndose. NOTA: El botn se puede apagar con un segundo empujn o apagando el grifo. NOTA: Despus del inicio, enjuague el sistema de acuerdo con las especificaciones del fabricante. Puede que tome algunos ciclos para que el botn permanezca encendido mientras aire sea expulsado del sistema. 18 GUA DE LA PANTALLA DEL BOTN Luces de Capacidad del Filtro: Ensean 1-6 luces dependiendo de la capacidad del filtro que le quede, 6 luces = >80% y 1 luz = <10%. Logo Culligan: Enciende cuando agua filtrada no est disponible desde el grifo. Permanece encendido mientras agua filtrada corra desde el grifo. Alarma: Enciende cuando las bateras de la caja de control, los filtros, o la membrana de osmosis inverso deben ser reemplazados. OPERACIN DE LA CAJA DE CONTROL RESET POWER REPLACE BATTERIES REPLACE FILTERS REPLACE RO MEMBRANE Botn de reinicio de capacidad del filtro. Fuerza: Enciende de color verde al inicio, cuando reinicia la capacidad del filtro, y mientras corra agua filtrada. La luz parpadear por 1 minuto despus de que se cierre el flujo de agua. Reemplazo de Bateras: Enciende de color rojo cuando las bateras para la caja de control deben ser reemplazadas. Reemplazo de Filtros: Enciende de color rojo cuando los filtros tienen menos de 10% de vida segn indica el flujo o el tiempo. Este indicador se reinicia empujando el botn de reinicio por dos segundos. Reemplazo de Membrana de Osmosis Inverso:
Enciende de color rojo cuando el agua filtrada tiene un nivel de TDS mayor de 25% del agua no filtrada. Este indicador se reinicia automaticamente cuando se detecta TDS bajo en el agua. 19 SOLUCIN DE PROBLEMAS FUGAS DE AGUA POR ENTRADA O SALIDA DEL FILTRO/SISTEMA DE OSMOSIS INVERSO:
Una arendala doblada podra estorbar en entrada completa del tubo. Use un destornillador pequeo para asentar la arendala de nuevo, y entonces asegurarse de que el extremo del tubo tenga una cortada cuadrada, y limpia. FLUJO BAJO DE AGUA FILTRADA/EL SISTEMA CAMBIA DE AGUA FILTRADA A AGUA NO FILTRADA AUTOMATICAMENTE:
El flujo bajo quiz no este activando la caja de control. Consulte el manual de su sistema de filtracin para averiguar cmo aumentar el flujo de agua. EL BOTN COMUNICA PERO NO HAY CAMBIO EN EL FLUJO:
Confirme que la vlvula de derivacin est en la posicin cerrada/apuntada hacia abajo. EL BOTN NO COMUNICA SIEMPRE:
Algunos materiales pueden estorbar la seal inalmbrica mas que otros. Puede probar la seal moviendo el botn a otra area ubicada ms de cerca a la caja de control. EL AGUA FILTRADA NO SE APAGA: Bateras de poca fuerza en la caja de control pueden causar que el sistema se quede en la posicin de agua filtrada. Se puede emplear la vlvula de derivacin para permitir el flujo de agua no filtrada al grifo mientras se corrija el asunto. 20 GARANTA LIMITADA DE UN AO La garanta se aplica al botn y la caja de batera. La garanta cubre los defectos en el material y la fabricacin por un ao completo desde la fecha original de entrega. Culligan reemplazar cualquier pieza que se considere defectuosa, con las siguientes excepciones: (1) si algn componente de la unidad estuvo sujeto a algn tipo de manipulacin, alteracin o uso inapropiado despus de la entrega, o (2) si haba sido reparado por una agencia no aprobada por Culligan. Este producto ha sido diseado solamente para ser usado como un control de filtracin de agua. La garanta NO cubre daos producidos debido a las temperaturas bajo cero o el aumento repentino de presin de agua. El uso indebido de este producto y sus componentes podra provocar defectos o deterioro no estn cubiertos por la garanta. LA GARANTA SUSODICHA ES EXCLUSIVA Y SUSTITUYE CUALQUIER OTRA GARANTA, EXPRESA O IMPLCITA, YA SEA UNA GARANTA VERBAL O UNA QUE DERIVE DEL USO O LA PRCTICA COMERCIAL, INCLUIDA, DE MANERA SIN LMITE, CUALQUIER GARANTA DE APTITUD O COMERCIABILIDAD. ESTA GARANTA ES EL NICO RECURSO EXCLUSIVO DEL COMPRADOR. BAJO NINGUNA CIRCUNSTANCIA CULLIGAN ASUMIR LA RESPONSABILIDAD POR LA PRDIDA DE GANANCIAS ANTICIPADAS, LOS DAOS ACCIDENTALES, DAOS CONSECUENTES, GASTOS, GASTOS DE TIEMPO DE MANO DE OBRA U OTRO TIPO DE PRDIDAS, SEA POR EL INCUMPLIMIENTO DEL CONTRATO, UNA CONDUCTA ILCITA O CUALQUIER OTRA TEORA, EN RELACIN CON LA COMPRA, LA INSTALACIN, LA REPARACIN O EL FUNCIONAMIENTO DE ESTE PRODUCTO. CULLIGAN NO AUTORIZA A NINGUNA PERSONA A ASUMIR RESPONSABILIDADES U OTORGAR GARANTAS ADICIONALES EN SU NOMBRE EN RELACIN CON ESTE PRODUCTO. 21 Culligan International Company Rosemont, Illinois 60018 www.culligan.com 2015 Culligan International Company 01029457 A DRINKING WATER | AGUA POTABLE ClearLink Wireless Filtration Control Installation and operating instructions Model US-CL ClearLink Control de Filtracin de Agua Inalmbrico Instrucciones de instalacin y operacin Modelo US-CL English PARTS INCLUDED:
Remote Button Control Box Battery Box 3/8" x 1/4" Tube Adapters Mounting Screws Air Gap SPECIFICATIONS Pressure Range:
Temperature Range:
30 120 psi (207827 kPa) 40 100F (4.4 37.7C) TOOLS & MATERIALS REQUIRED C Batteries x4 AAA Batteries x2 Screwdriver Adjustable Wrench Towels Pan or Bucket PRECAUTIONS WARNING: Follow all precautions indicated in the manual provided with the water treatment system. WARNING: For systems using a booster or distribution pump, the pressure of the treated water cannot exceed the pressure of the cold water supply. CAUTION: Control box must be protected against freezing temperatures, frost, snow, sleet, and ice. Exposure to these can produce cracks and product failures. CAUTION: This product has a limited service life. We recommend that a record be kept regarding the date of install and any other performed maintenance. Because of the products limited service life and to prevent costly repairs or possible water damage, we strongly recommend that the control box be replaced every ten years. WARNING: For cold water use only. Do not use on hot water line. After prolonged periods of non-use (such as during a vacation) it is recommended that the system be flushed thoroughly. Let the filtered water run for 56 minutes before using. The US-CL estimates filter life based on flow and time. Changes in taste, odor, color, and/or flow of the filtered water could indicate that the filter(s) should be replaced. Make certain that installation complies with all state and local laws and regulations. 2 UNIVERSAL WIRELESS FILTRATION CONTROL PARTS INCLUDED:
Remote Button Control Box Battery Box 3/8" x 1/4" Tube Adpaters Mounting Screws Air Gap 3 INSTALLATION NOTE: Refer to the manual provided with your filter/RO for installation instructions specific to that system. NOTE: Some installations may require adapters and fittings not included with the product. Review the manual and your installation before beginning. NOTE: Consult your local plumbing codes and install accordingly. Turn off cold water shut-off valve then turn on the kitchen faucet and allow all water to drain from line. Disconnect the cold water line from the cold water shut-off valve. NOTE: If rigid plumbing pipe (metal or plastic) is used, you may need to shorten the pipe using a hacksaw or pipe cutter to accommodate the control box. 4 Tighten the control box to the cold water shut-off valve as shown. Tighten the lower end of cold water line onto the top of the control box. NOTE: The control box must be in a vertical position. NOTE: If space does not allow for mounting the control box onto the valve, it can be alternatively hung on a wall when using the holes on the back and a flex connection (purchased separately). Connect the inlet on the RO/Filter system to the blue port marked "RO/Filter >." Wet the end of the plastic tubing with water and push it into the quick connect fitting adapter approximately 5/8 until it stops. NOTE: This is the line that would normally come from the water supply adapter. NOTE: Use one of the supplied adapters if your system uses 1/4" tube. Connect the outlet on the RO/Filter system to the white port marked "RO/Filter <." Wet the end of the plastic tubing with water and push it into the quick connect fitting adapter approximately 5/8"
until it stops. NOTE: This is the line that would normally go to your dedicated faucet. NOTE: Use one of the supplied adapters if your system uses a 1/4" tube. NOTE: Connect the tank and/or post filter in this line if required for your filter/RO system. 5 RO AIR GAP INSTALLATION NOTE: These steps are only for RO installations using an air gap. NOTE: Not all systems require an air gap. Only systems using a drain connection NOTE: If your filtration system does not have a drain connection, skip to System Startup on Page 7. NOTE: Install the drain connection to the drain plumbing according to the manual provided with your RO system. require the use of an air gap. AIR GAP Mount the air gap device as near to counter top as possible and in a vertical orientation. NOTE: Failure to mount the air gap device vertically will cause it to leak water. Connect the drain line coming from the RO system to the small connection of the air gap device. Connect the large fitting of the air gap device to the connection on the drain plumbing. 6 SYSTEM STARTUP BYPASS Confirm that the bypass valve is in the closed position (pointed down). Turn on the cold water supply and check for leaks. If it leaks, refer to troubleshooting. Install four C batteries (not included) into the battery box and plug into the jack on the bottom of the control box. NOTE: The control box will beep and flash the power light when powering up. 7 Use the provided screw to hang the battery box on the side of the cabinet. SYSTEM STARTUP Install two AAA batteries (not included) into the remote button. Turn on the faucet to full cold and push the button to activate the system. NOTE: The blue capacity lights should appear if the button and control box are communicating. NOTE: The button can be turned off with a second push or by turning off the faucet. NOTE: After startup, flush your system according to manufacturer's specifications. It might take a few cycles for the button to stay on while air is purged from the system. 8 BUTTON DISPLAY GUIDE Filter Capacity Lights: Shows from 1-6 lights depending on filter capacity remaining, 6 lights = >80% and 1 light = <10%. Culligan Logo: Flashes when treated water is not available from the faucet. Stays solid while treated water is being dispensed from the faucet. Alert Indicator: Illuminates when the control box batteries need replacing or filters need replacing. CONTROL BOX OPERATION RESET POWER REPLACE BATTERIES REPLACE FILTERS Reset button for filter capacity. Power: Flashes green at power up, filter capacity reset, and while dispensing filtered water. Continues to flash for 1 minute after the flow of filtered water has stopped. Replace Batteries: Flashes red when the batteries for the control box need to be replaced. This indicator automatically clears when new batteries are detected. Replace Filters: Flashes red when the filters have less than 10% of their life remaining due to flow or time. This indicator is reset by pressing the reset button for two seconds. 9 TROUBLESHOOTING LEAKS AT FILTER/RO INLET OR OUTLET CONNECTION:
A rolled o-ring can block the tube from fully inserting. Use small screw driver to re-seat the o-ring and then confirm that the end of the tubing has a clean, square cut. LOW FILTERED WATER FLOW/SYSTEM RETURNS TO UNFILTERED FLOW AUTOMATICALLY:
Low flow rates may not activate the control box electronics. Refer to your system manual to trouble shoot a low flow condition. BUTTON IS COMMUNICATING BUT NO CHANGE IN WATER FLOW:
Confirm that the bypass valve is in the down/closed position. BUTTON COMMUNICATION IS INTERMITTENT:
Some materials may block the wireless signal more than others. Try moving the button to an area on the counter that is closer to the under-sink control box. FILTERED WATER FLOW WON'T TURN OFF:
Low batteries for the control box can cause the system to be stuck in the filtered position. The bypass valve can be used to allow unfiltered water flow to the faucet while the issue is being corrected. If leaks persist, or if there are other leaks from the control box, turn off water supply. Call technical support at 1-800-721-7360. PRODUCT REGISTRATION Please be sure to go online within 30 days of purchase and register your product at www.register.culligan.com. Model: CulRF-M used in devices ClearLink PB, ClearLink RI and ClearLink R Contains the FCC ID: V7U-010291CL and IC: 6510B-010291CL This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. THE US-CL IS CERTIFIED BY WQA AGAINST CSA B483.1, NSF/ANSI 372 FOR LOW LEAD REQUIREMENT, NSF/ANSI 42 AND NSF/ANSI 58 FOR MATERIAL SAFETY AND STRUCTURAL INTEGRITY 10 ONE-YEAR LIMITED WARRANTY This warranty applies to the button, control box and battery box. This warranty covers defects in material and workmanship only for 1 full year from the original date of delivery. Culligan will replace any part which in Culligans opinion is defective, unless: (1) any part of the unit has been subjected to any type of tampering, alteration, or improper use after delivery, or (2) it has been repaired by anyone not approved by Culligan. Culligan is not responsible for damage in transit, and claims for such damage should be presented to the carrier by the customer. This warranty does not cover any labor, transportation, or shipping expenses incurred. The hiring of any individual or service to install or maintain this product is done at the discretion and expense of the purchaser. This product has been designed solely for use as a water filtration control. It is NOT warranted against freezing or surges in water pressure, and neither this product nor its parts is warranted against defects or deterioration caused by uses for which this product was not expressly intended. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, WHETHER ORAL OR ARISING BY USAGE OF TRADE OR COURSE OF DEALING, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF FITNESS OR MERCHANTABILITY. THIS WARRANTY IS THE PURCHASERS SOLE AND EXCLUSIVE REMEDY, IN NO EVENT SHALL CULLIGAN BE LIABLE FOR ANY ANTICIPATED OR LOST PROFITS, INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, COSTS, TIME CHARGES OR OTHER LOSSES, WHETHER BASED ON BREACH OF CONTRACT, TORTIOUS CONDUCT OR ANY OTHER THEORY, INCURRED IN CONNECTION WITH THE PURCHASE, INSTALLATION, REPAIR OR OPERATION OF THIS PRODUCT. CULLIGAN DOES NOT AUTHORIZE ANYONE TO ASSUME FOR IT ANY LIABILITY OR TO MAKE ON ITS BEHALF ANY ADDITIONAL WARRANTIES IN CONNECTION WITH THE FILTER HOUSING OR ANY PART THEREOF. For servicing under this warranty, return any defective part to YOUR RETAILER within the 1 year period referred to above. Be sure that you complete the online warranty registration within 30 days of purchase and keep your original receipt, order form, or bill of sale to serve as a proof of purchase before returning. Model: CulRF-M used in devices ClearLink PB, ClearLink RI and ClearLink R Contains the FCC ID: V7U-010291CL and IC: 6510B-010291CL This device complies with part 15 of the FCC Rules subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept all interference received including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil nedoit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. This device complies with Health Canadas Safety Code. The installer of this device should ensure that RF radiation is not emitted in excess of the Health Canadas requirement. Cet appareil est conforme avec Sant Canada Code de scurit 6. Le programme dinstallation de cet appareil doit sassurer que les rayonnements RF nest pas mis au-del de Iexigence de Sant Canada. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Les changements ou modifications non expressment approuvs par la partie responsable de la conformit pourraient annuler l'autorit de l'utilisateur utiliser cet quipement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. 11 Espaol PIEZAS INCLUIDO Botn del Control Remoto Caja de Control Caja de Batera Adaptadores 3/8" x 1/4"
Tornillos de Montaje Entrehierro HERRAMIENTAS Y MATERIALES REQUERIDOS Bateras C x4 Bateras AAA x2 Destornillador Llave Ajustable Toallas Bandeja o Cubeta ESPECIFICACIONES Gama de Presin:
Gama de Temperatura:
30 120 psi (207827 kPa) 40 100F (4.4 37.7C) PRECAUCIONES ADVERTENCIA: Siga todas las precauciones indicadas en el manual provisto con el sistema de tratamiento de agua de Culligan. ADVERTENCIA: Para sistemas empleando una bomba amplificador o de distribucin, la presin del agua no tratado no puede exceder la presin del agua fra del suministro. PRECAUCIN: Se exige que la caja de control sea protegida de temperaturas bajo cero,escarcha, nieve, aguanieve, y hielo. El producto puede fallar si se expone a estos elementos. PRECAUCIN: Este producto lleva una vida de servicio limitada. Se recomienda que se lleve un registro de la instalacin y de cualquier otro mantenimiento. Debido a la vida de servicio limitada, y para evitar reparaciones costosas o posibles daos por agua, se recomienda enfticamente que la caja de control sea reemplazada cada diez aos. ADVERTENCIA: Se debe utilizar nicamente con agua fra. No se debe utilizar con agua caliente. Despus de periodos extendidos sin uso (p. ej. durante vacaciones) es aconsejable enjuagar el sistema dejando correr el agua por 5-6 minutos antes de usarlo. El US-CL mide la vida de un filtro segn el nivel de flujo y el tiempo. Cambios en el sabor, olor, color, y/o el flujo de agua filtrada podra indicar que el filtro debe ser reemplazado. Asegrese de que la instalacin cumpla con todas las leyes y regulaciones locales y estatales. 12 CONTROL DE FILTRACIN INALMBRICO UNIVERSAL PIEZAS INCLUIDAS:
Botn del Control Remoto Caja de Control Caja de Batera Adaptadores de Tubo 3/8" x 1/4"
Tornillos de Montaje Entrehierro 13 INSTALACIN NOTA: Favor de referirse al manual provisto con su filtro/sistema de osmosis inverso para las instrucciones de instalacin especificadas para s sistema de filtracin. NOTA: Algunas instalaciones exigen adaptadores u otras piezas no incluidas con NOTA: Consulte y instale de acuerdo con los cdigos de plomera locales. este producto. Repase el manual y el proceso de instalacin antes de comenzar. Desconecte la lnea de suministro de agua fra, despus abra el grifo de la cocina y deje que drene toda el agua de la caera. Desconecte la lnea de agua fra de la vlvula de cierre de agua fra. NOTA: Si utiliza tubera rgida (de metal o plstico), es posible que deba acortar la tubera con una sierra para metales o un cortatubos a fin de hacer espacio para la caja de control. 14 Aprieta la caja de control a la vlvula de cierre de agua fra segn la diagrama. Aprieta la parte inferior de la lnea de agua fra a la parte superior de la caja de control. NOTA: Se exige que la caja de control se instale verticalmente. NOTA: Si el espacio no permite que se monte la caja de control a la vlvula, puede ser colgada en una pared usando conectadores flexibles
(se vende aparte) como una alternativa. Conecte la entrada del sistema de filtracin al puerto azul titulado "RO/Filter>" de la caja de control. Moje el extremo del tubo de plstico con agua y empjelo en el adaptador de conexin rpido aproximadamente 5/8" hasta que pare. NOTA: Esta es la lnea que normalmente correra desde el adaptador de suministro de agua. NOTA: Use uno de los adaptadores suministrados si su sistema emplea un tubo que mide 1/4". Conecte la salida del sistema de filtracin al puerto blanco titulado "RO/Filter<" de la caja de control. Moje el extremo del tubo de plstico con agua y empjelo en el adaptador de conexin rpido aproximadamente 5/8" hasta que pare. NOTA: Esta es la lnea que normalmente correra hacia el grifo dedicado. NOTA: Use uno de los adaptadores suministrados si su sistema emplea un tubo que mide 1/4". NOTA: Despus del inicio, enjuague su sistema segn las instrucciones del fabricante. 15 empleando un entrehierro. INSTALACIN DE ENTREHIERRO PARA OSMOSIS INVERSO NOTA: Los siguientes pasos aplican nicamente a instalaciones de osmosis inverso NOTA: No se exige un entrehierro con todos los sistemas. Slamente los sistemas NOTA: Si su sistema de filtracin no es de osmosis inverso, brinque a la seccin NOTA: Instale el conectador de drenaje al drenaje de acuerdo con el manual provisto usando una conexin de drenaje necesitan el uso de un entrehierro. de Inicio del Sistema en la pgina 7. con s sistema de osmosis inverso. ENTREHIERRO Monte el entrehierro en la posicin vertical lo ms cerca posible a la encimera. NOTA: El entrehierro derramar agua si no se instala verticalmente. Conecte la lnea de drenaje saliendo del sistema de osmosis inverso a la pequea conexin pa del entrehierro. Conecte la pa grande del entrehierro a la conexin de drenaje. 16 INICIO DEL SISTEMA BYPASS Asegrese que la vlvula de derivacin est en la posicin cerrada (apuntada hacia abajo). Abra el suministro de agua fra para averiguar si se derrama agua o no. Si el sistema est derramando agua, consulte la seccin de Solucin de Problemas. Instale cuatro bateras C (no incluidas) en la caja de pilas y enchufe al gato en la parte inferior de la caja de control. NOTA: La caja de control emitir un pitido y la luz de fuerza parpadear al encender. 17 Use el tornillo provisto para colgar la caja de bateras a la pared interior del cabinete. INICIO DEL SISTEMA Instale dos bateras AAA (no incluidas) en el botn de control remoto. Abra el grifo de agua fra completamente y empuja el botn para activar el sistema. NOTA: La luces azules de capacidad deben encenderse si el botn y la caja de control estn comunicndose. NOTA: El botn se puede apagar con un segundo empujn o apagando el grifo. NOTA: Despus del inicio, enjuague el sistema de acuerdo con las especificaciones del fabricante. Puede que tome algunos ciclos para que el botn permanezca encendido mientras aire sea expulsado del sistema. 18 GUA DE LA PANTALLA DEL BOTN Luces de Capacidad del Filtro: Ensean 1-6 luces dependiendo de la capacidad del filtro que le quede, 6 luces = >80% y 1 luz = <10%. Logo Culligan: Enciende cuando agua filtrada no est disponible desde el grifo. Permanece encendido mientras agua filtrada corra desde el grifo. Alarma: Enciende cuando las bateras de la caja de control, los filtros, o la membrana de osmosis inverso deben ser reemplazados. OPERACIN DE LA CAJA DE CONTROL RESET POWER REPLACE BATTERIES REPLACE FILTERS Botn de reinicio de capacidad del filtro. Fuerza: Enciende de color verde al inicio, cuando reinicia la capacidad del filtro, y mientras corra agua filtrada. La luz parpadear por 1 minuto despus de que se cierre el flujo de agua. Reemplazo de Bateras: Enciende de color rojo cuando las bateras para la caja de control deben ser reemplazadas. Reemplazo de Filtros: Enciende de color rojo cuando los filtros tienen menos de 10% de vida segn indica el flujo o el tiempo. Este indicador se reinicia empujando el botn de reinicio por dos segundos. 19 SOLUCIN DE PROBLEMAS FUGAS DE AGUA POR ENTRADA O SALIDA DEL FILTRO/SISTEMA DE OSMOSIS INVERSO:
Una arendala doblada podra estorbar en entrada completa del tubo. Use un destornillador pequeo para asentar la arendala de nuevo, y entonces asegurarse de que el extremo del tubo tenga una cortada cuadrada, y limpia. FLUJO BAJO DE AGUA FILTRADA/EL SISTEMA CAMBIA DE AGUA FILTRADA A AGUA NO FILTRADA AUTOMATICAMENTE:
El flujo bajo quiz no este activando la caja de control. Consulte el manual de su sistema de filtracin para averiguar cmo aumentar el flujo de agua. EL BOTN COMUNICA PERO NO HAY CAMBIO EN EL FLUJO:
Confirme que la vlvula de derivacin est en la posicin cerrada/apuntada hacia abajo. EL BOTN NO COMUNICA SIEMPRE:
Algunos materiales pueden estorbar la seal inalmbrica mas que otros. Intente mover el botn a otra area ubicada ms de cerca a la caja de control. EL AGUA FILTRADA NO SE APAGA: Bateras de poca fuerza en la caja de control pueden causar que el sistema se quede en la posicin de agua filtrada. Se puede emplear la vlvula de derivacin para permitir el flujo de agua no filtrada al grifo mientras se corrija el asunto. Si las fugas de agua persisten, o si hay otras fugas de agua de la caja de control, favor de apagar el suministro de agua. Srvase llamar para ayuda tcnica a 1-800-721-7360. REGISTRO DE PRODUCTO Asegrese de registrar la compra de su producto en lnea dentro de los 30 das a partir de la compra en www.register.culligan.com. LAS US-CL HA SIDO CERTIFICADOS POR LA WQA SEGN LAS NORMAS CSA B483.1, NSF/ANSI 372 PARA EL REQUISITO DE PLOMO BAJO, NSF/ANSI 42 Y NSF/ANSI 58 PARA LA SEGURIDAD DE LOS MATERIALES Y LA INTEGRIDAD ESTRUCTURAL 20 GARANTA LIMITADA DE UN AO La garanta se aplica al botn y la caja de batera. La garanta cubre los defectos en el material y la fabricacin por un ao completo desde la fecha original de entrega. Culligan reemplazar cualquier pieza que se considere defectuosa, con las siguientes excepciones: (1) si algn componente de la unidad estuvo sujeto a algn tipo de manipulacin, alteracin o uso inapropiado despus de la entrega, o (2) si haba sido reparado por una agencia no aprobada por Culligan. Culligan no asume responsabilidad alguna por los daos durante el transporte, y en caso de algn reclamo debido a dichos daos, el cliente deber presentar el reclamo ante el transportista. Esta garanta no cubre ningn tipo de gastos de envo, transporte o mano de obra en los que se haya incurrido. La contratacin de un individuo o un servicio para la instalacin o mantenimiento de este producto se hace a la discrecin del comprador y, por lo tanto, cualquier gasto incurrido es responsabilidad del comprador mismo. Este producto ha sido diseado solamente para ser usado como un control de filtracin de agua. La garanta NO cubre daos producidos debido a las temperaturas bajo cero o el aumento repentino de presin de agua. El uso indebido de este producto y sus componentes podra provocar defectos o deterioro no estn cubiertos por la garanta. LA GARANTA SUSODICHA ES EXCLUSIVA Y SUSTITUYE CUALQUIER OTRA GARANTA, EXPRESA O IMPLCITA, YA SEA UNA GARANTA VERBAL O UNA QUE DERIVE DEL USO O LA PRCTICA COMERCIAL, INCLUIDA, DE MANERA SIN LMITE, CUALQUIER GARANTA DE APTITUD O COMERCIABILIDAD. ESTA GARANTA ES EL NICO RECURSO EXCLUSIVO DEL COMPRADOR. BAJO NINGUNA CIRCUNSTANCIA CULLIGAN ASUMIR LA RESPONSABILIDAD POR LA PRDIDA DE GANANCIAS ANTICIPADAS, LOS DAOS ACCIDENTALES, DAOS CONSECUENTES, GASTOS, GASTOS DE TIEMPO DE MANO DE OBRA U OTRO TIPO DE PRDIDAS, SEA POR EL INCUMPLIMIENTO DEL CONTRATO, UNA CONDUCTA ILCITA O CUALQUIER OTRA TEORA, EN RELACIN CON LA COMPRA, LA INSTALACIN, LA REPARACIN O EL FUNCIONAMIENTO DE ESTE PRODUCTO. CULLIGAN NO AUTORIZA A NINGUNA PERSONA A ASUMIR RESPONSABILIDADES U OTORGAR GARANTAS ADICIONALES EN SU NOMBRE EN RELACIN CON ESTE PRODUCTO. Para obtener un servicio conforme a esta garanta, deber devolver cualquier pieza defectuosa a SU COMERCIANTE dentro del plazo de un ao especificado anteriormente. Asegrese de completar el registro de garanta en lnea dentro de los 30 das a partir de la compra y conserve la factura original, la orden de compra o el comprobante de venta, ya que sirven como prueba de la compra para poder realizar una devolucin. 21 Culligan International Company Rosemont, Illinois 60018 www.culligan.com Technical Support MF 8:00AM4:30PM (CST) Ayuda Tcnica disponible de lunes a viernes, de 8:00 A.M. a 4:30 P.M. (CST) 1-800-721-7360 2015 Culligan International Company 01029484 B DRINKING WATER | AGUA POTABLE ClearLink Wireless Filtration Control Installation and operating instructions Model US-CL ClearLink Control de Filtracin de Agua Inalmbrico Instrucciones de instalacin y operacin Modelo US-CL English PARTS INCLUDED:
Remote Button Control Box Battery Box 3/8" x 1/4" Tube Adapters Mounting Screws Air Gap SPECIFICATIONS Pressure Range:
Temperature Range:
30 120 psi (207827 kPa) 40 100F (4.4 37.7C) TOOLS & MATERIALS REQUIRED C Batteries x4 AAA Batteries x2 Screwdriver Adjustable Wrench Towels Pan or Bucket PRECAUTIONS WARNING: Follow all precautions indicated in the manual provided with the water treatment system. WARNING: For systems using a booster or distribution pump, the pressure of the treated water cannot exceed the pressure of the cold water supply. CAUTION: Control box must be protected against freezing temperatures, frost, snow, sleet, and ice. Exposure to these can produce cracks and product failures. CAUTION: This product has a limited service life. We recommend that a record be kept regarding the date of install and any other performed maintenance. Because of the products limited service life and to prevent costly repairs or possible water damage, we strongly recommend that the control box be replaced every ten years. WARNING: For cold water use only. Do not use on hot water line. After prolonged periods of non-use (such as during a vacation) it is recommended that the system be flushed thoroughly. Let the filtered water run for 56 minutes before using. The US-CL estimates filter life based on flow and time. Changes in taste, odor, color, and/or flow of the filtered water could indicate that the filter(s) should be replaced. Make certain that installation complies with all state and local laws and regulations. 2 UNIVERSAL WIRELESS FILTRATION CONTROL PARTS INCLUDED:
Remote Button Control Box Battery Box 3/8" x 1/4" Tube Adpaters Mounting Screws Air Gap 3 INSTALLATION NOTE: Refer to the manual provided with your filter/RO for installation instructions specific to that system. NOTE: Some installations may require adapters and fittings not included with the product. Review the manual and your installation before beginning. NOTE: Consult your local plumbing codes and install accordingly. Turn off cold water shut-off valve then turn on the kitchen faucet and allow all water to drain from line. Disconnect the cold water line from the cold water shut-off valve. NOTE: If rigid plumbing pipe (metal or plastic) is used, you may need to shorten the pipe using a hacksaw or pipe cutter to accommodate the control box. 4 Tighten the control box to the cold water shut-off valve as shown. Tighten the lower end of cold water line onto the top of the control box. NOTE: The control box must be in a vertical position. NOTE: If space does not allow for mounting the control box onto the valve, it can be alternatively hung on a wall when using the holes on the back and a flex connection (purchased separately). Connect the inlet on the RO/Filter system to the blue port marked "RO/Filter >." Wet the end of the plastic tubing with water and push it into the quick connect fitting adapter approximately 5/8 until it stops. NOTE: This is the line that would normally come from the water supply adapter. NOTE: Use one of the supplied adapters if your system uses 1/4" tube. Connect the outlet on the RO/Filter system to the white port marked "RO/Filter <." Wet the end of the plastic tubing with water and push it into the quick connect fitting adapter approximately 5/8"
until it stops. NOTE: This is the line that would normally go to your dedicated faucet. NOTE: Use one of the supplied adapters if your system uses a 1/4" tube. NOTE: Connect the tank and/or post filter in this line if required for your filter/RO system. 5 RO AIR GAP INSTALLATION NOTE: These steps are only for RO installations using an air gap. NOTE: Not all systems require an air gap. Only systems using a drain connection NOTE: If your filtration system does not have a drain connection, skip to System Startup on Page 7. NOTE: Install the drain connection to the drain plumbing according to the manual provided with your RO system. require the use of an air gap. AIR GAP Mount the air gap device as near to counter top as possible and in a vertical orientation. NOTE: Failure to mount the air gap device vertically will cause it to leak water. Connect the drain line coming from the RO system to the small connection of the air gap device. Connect the large fitting of the air gap device to the connection on the drain plumbing. 6 SYSTEM STARTUP BYPASS Confirm that the bypass valve is in the closed position (pointed down). Turn on the cold water supply and check for leaks. If it leaks, refer to troubleshooting. Install four C batteries (not included) into the battery box and plug into the jack on the bottom of the control box. NOTE: The control box will beep and flash the power light when powering up. 7 Use the provided screw to hang the battery box on the side of the cabinet. SYSTEM STARTUP Install two AAA batteries (not included) into the remote button. Turn on the faucet to full cold and push the button to activate the system. NOTE: The blue capacity lights should appear if the button and control box are communicating. NOTE: The button can be turned off with a second push or by turning off the faucet. NOTE: After startup, flush your system according to manufacturer's specifications. It might take a few cycles for the button to stay on while air is purged from the system. 8 BUTTON DISPLAY GUIDE Filter Capacity Lights: Shows from 1-6 lights depending on filter capacity remaining, 6 lights = >80% and 1 light = <10%. Culligan Logo: Flashes when treated water is not available from the faucet. Stays solid while treated water is being dispensed from the faucet. Alert Indicator: Illuminates when the control box batteries need replacing or filters need replacing. CONTROL BOX OPERATION RESET POWER REPLACE BATTERIES REPLACE FILTERS Reset button for filter capacity. Power: Flashes green at power up, filter capacity reset, and while dispensing filtered water. Continues to flash for 1 minute after the flow of filtered water has stopped. Replace Batteries: Flashes red when the batteries for the control box need to be replaced. This indicator automatically clears when new batteries are detected. Replace Filters: Flashes red when the filters have less than 10% of their life remaining due to flow or time. This indicator is reset by pressing the reset button for two seconds. 9 TROUBLESHOOTING LEAKS AT FILTER/RO INLET OR OUTLET CONNECTION:
A rolled o-ring can block the tube from fully inserting. Use small screw driver to re-seat the o-ring and then confirm that the end of the tubing has a clean, square cut. LOW FILTERED WATER FLOW/SYSTEM RETURNS TO UNFILTERED FLOW AUTOMATICALLY:
Low flow rates may not activate the control box electronics. Refer to your system manual to trouble shoot a low flow condition. BUTTON IS COMMUNICATING BUT NO CHANGE IN WATER FLOW:
Confirm that the bypass valve is in the down/closed position. BUTTON COMMUNICATION IS INTERMITTENT:
Some materials may block the wireless signal more than others. Try moving the button to an area on the counter that is closer to the under-sink control box. FILTERED WATER FLOW WON'T TURN OFF:
Low batteries for the control box can cause the system to be stuck in the filtered position. The bypass valve can be used to allow unfiltered water flow to the faucet while the issue is being corrected. If leaks persist, or if there are other leaks from the control box, turn off water supply. Call technical support at 1-800-721-7360. PRODUCT REGISTRATION Please be sure to go online within 30 days of purchase and register your product at www.register.culligan.com. Model: CulRF-M used in devices ClearLink PB, ClearLink RI and ClearLink R Contains the FCC ID: V7U-010291CL and IC: 6510B-010291CL This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. 10 ONE-YEAR LIMITED WARRANTY This warranty applies to the button, control box and battery box. This warranty covers defects in material and workmanship only for 1 full year from the original date of delivery. Culligan will replace any part which in Culligans opinion is defective, unless: (1) any part of the unit has been subjected to any type of tampering, alteration, or improper use after delivery, or (2) it has been repaired by anyone not approved by Culligan. Culligan is not responsible for damage in transit, and claims for such damage should be presented to the carrier by the customer. This warranty does not cover any labor, transportation, or shipping expenses incurred. The hiring of any individual or service to install or maintain this product is done at the discretion and expense of the purchaser. This product has been designed solely for use as a water filtration control. It is NOT warranted against freezing or surges in water pressure, and neither this product nor its parts is warranted against defects or deterioration caused by uses for which this product was not expressly intended. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, WHETHER ORAL OR ARISING BY USAGE OF TRADE OR COURSE OF DEALING, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF FITNESS OR MERCHANTABILITY. THIS WARRANTY IS THE PURCHASERS SOLE AND EXCLUSIVE REMEDY, IN NO EVENT SHALL CULLIGAN BE LIABLE FOR ANY ANTICIPATED OR LOST PROFITS, INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, COSTS, TIME CHARGES OR OTHER LOSSES, WHETHER BASED ON BREACH OF CONTRACT, TORTIOUS CONDUCT OR ANY OTHER THEORY, INCURRED IN CONNECTION WITH THE PURCHASE, INSTALLATION, REPAIR OR OPERATION OF THIS PRODUCT. CULLIGAN DOES NOT AUTHORIZE ANYONE TO ASSUME FOR IT ANY LIABILITY OR TO MAKE ON ITS BEHALF ANY ADDITIONAL WARRANTIES IN CONNECTION WITH THE FILTER HOUSING OR ANY PART THEREOF. For servicing under this warranty, return any defective part to YOUR RETAILER within the 1 year period referred to above. Be sure that you complete the online warranty registration within 30 days of purchase and keep your original receipt, order form, or bill of sale to serve as a proof of purchase before returning. Model: CulRF-M used in devices ClearLink PB, ClearLink RI and ClearLink R Contains the FCC ID: V7U-010291CL and IC: 6510B-010291CL This device complies with part 15 of the FCC Rules subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept all interference received including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorise aux deux conditions suivantes : (1) l'appareil nedoit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible d'en compromettre le fonctionnement. This device complies with Health Canadas Safety Code. The installer of this device should ensure that RF radiation is not emitted in excess of the Health Canadas requirement. Cet appareil est conforme avec Sant Canada Code de scurit 6. Le programme dinstallation de cet appareil doit sassurer que les rayonnements RF nest pas mis au-del de Iexigence de Sant Canada. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Les changements ou modifications non expressment approuvs par la partie responsable de la conformit pourraient annuler l'autorit de l'utilisateur utiliser cet quipement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. 11 Espaol PIEZAS INCLUIDO Botn del Control Remoto Caja de Control Caja de Batera Adaptadores 3/8" x 1/4"
Tornillos de Montaje Entrehierro HERRAMIENTAS Y MATERIALES REQUERIDOS Bateras C x4 Bateras AAA x2 Destornillador Llave Ajustable Toallas Bandeja o Cubeta ESPECIFICACIONES Gama de Presin:
Gama de Temperatura:
30 120 psi (207827 kPa) 40 100F (4.4 37.7C) PRECAUCIONES ADVERTENCIA: Siga todas las precauciones indicadas en el manual provisto con el sistema de tratamiento de agua de Culligan. ADVERTENCIA: Para sistemas empleando una bomba amplificador o de distribucin, la presin del agua no tratado no puede exceder la presin del agua fra del suministro. PRECAUCIN: Se exige que la caja de control sea protegida de temperaturas bajo cero,escarcha, nieve, aguanieve, y hielo. El producto puede fallar si se expone a estos elementos. PRECAUCIN: Este producto lleva una vida de servicio limitada. Se recomienda que se lleve un registro de la instalacin y de cualquier otro mantenimiento. Debido a la vida de servicio limitada, y para evitar reparaciones costosas o posibles daos por agua, se recomienda enfticamente que la caja de control sea reemplazada cada diez aos. ADVERTENCIA: Se debe utilizar nicamente con agua fra. No se debe utilizar con agua caliente. Despus de periodos extendidos sin uso (p. ej. durante vacaciones) es aconsejable enjuagar el sistema dejando correr el agua por 5-6 minutos antes de usarlo. El US-CL mide la vida de un filtro segn el nivel de flujo y el tiempo. Cambios en el sabor, olor, color, y/o el flujo de agua filtrada podra indicar que el filtro debe ser reemplazado. Asegrese de que la instalacin cumpla con todas las leyes y regulaciones locales y estatales. 12 CONTROL DE FILTRACIN INALMBRICO UNIVERSAL PIEZAS INCLUIDAS:
Botn del Control Remoto Caja de Control Caja de Batera Adaptadores de Tubo 3/8" x 1/4"
Tornillos de Montaje Entrehierro 13 INSTALACIN NOTA: Favor de referirse al manual provisto con su filtro/sistema de osmosis inverso para las instrucciones de instalacin especificadas para s sistema de filtracin. NOTA: Algunas instalaciones exigen adaptadores u otras piezas no incluidas con NOTA: Consulte y instale de acuerdo con los cdigos de plomera locales. este producto. Repase el manual y el proceso de instalacin antes de comenzar. Desconecte la lnea de suministro de agua fra, despus abra el grifo de la cocina y deje que drene toda el agua de la caera. Desconecte la lnea de agua fra de la vlvula de cierre de agua fra. NOTA: Si utiliza tubera rgida (de metal o plstico), es posible que deba acortar la tubera con una sierra para metales o un cortatubos a fin de hacer espacio para la caja de control. 14 Aprieta la caja de control a la vlvula de cierre de agua fra segn la diagrama. Aprieta la parte inferior de la lnea de agua fra a la parte superior de la caja de control. NOTA: Se exige que la caja de control se instale verticalmente. NOTA: Si el espacio no permite que se monte la caja de control a la vlvula, puede ser colgada en una pared usando conectadores flexibles
(se vende aparte) como una alternativa. Conecte la entrada del sistema de filtracin al puerto azul titulado "RO/Filter>" de la caja de control. Moje el extremo del tubo de plstico con agua y empjelo en el adaptador de conexin rpido aproximadamente 5/8" hasta que pare. NOTA: Esta es la lnea que normalmente correra desde el adaptador de suministro de agua. NOTA: Use uno de los adaptadores suministrados si su sistema emplea un tubo que mide 1/4". Conecte la salida del sistema de filtracin al puerto blanco titulado "RO/Filter<" de la caja de control. Moje el extremo del tubo de plstico con agua y empjelo en el adaptador de conexin rpido aproximadamente 5/8" hasta que pare. NOTA: Esta es la lnea que normalmente correra hacia el grifo dedicado. NOTA: Use uno de los adaptadores suministrados si su sistema emplea un tubo que mide 1/4". NOTA: Despus del inicio, enjuague su sistema segn las instrucciones del fabricante. 15 empleando un entrehierro. INSTALACIN DE ENTREHIERRO PARA OSMOSIS INVERSO NOTA: Los siguientes pasos aplican nicamente a instalaciones de osmosis inverso NOTA: No se exige un entrehierro con todos los sistemas. Slamente los sistemas NOTA: Si su sistema de filtracin no es de osmosis inverso, brinque a la seccin NOTA: Instale el conectador de drenaje al drenaje de acuerdo con el manual provisto usando una conexin de drenaje necesitan el uso de un entrehierro. de Inicio del Sistema en la pgina 7. con s sistema de osmosis inverso. ENTREHIERRO Monte el entrehierro en la posicin vertical lo ms cerca posible a la encimera. NOTA: El entrehierro derramar agua si no se instala verticalmente. Conecte la lnea de drenaje saliendo del sistema de osmosis inverso a la pequea conexin pa del entrehierro. Conecte la pa grande del entrehierro a la conexin de drenaje. 16 INICIO DEL SISTEMA BYPASS Asegrese que la vlvula de derivacin est en la posicin cerrada (apuntada hacia abajo). Abra el suministro de agua fra para averiguar si se derrama agua o no. Si el sistema est derramando agua, consulte la seccin de Solucin de Problemas. Instale cuatro bateras C (no incluidas) en la caja de pilas y enchufe al gato en la parte inferior de la caja de control. NOTA: La caja de control emitir un pitido y la luz de fuerza parpadear al encender. 17 Use el tornillo provisto para colgar la caja de bateras a la pared interior del cabinete. INICIO DEL SISTEMA Instale dos bateras AAA (no incluidas) en el botn de control remoto. Abra el grifo de agua fra completamente y empuja el botn para activar el sistema. NOTA: La luces azules de capacidad deben encenderse si el botn y la caja de control estn comunicndose. NOTA: El botn se puede apagar con un segundo empujn o apagando el grifo. NOTA: Despus del inicio, enjuague el sistema de acuerdo con las especificaciones del fabricante. Puede que tome algunos ciclos para que el botn permanezca encendido mientras aire sea expulsado del sistema. 18 GUA DE LA PANTALLA DEL BOTN Luces de Capacidad del Filtro: Ensean 1-6 luces dependiendo de la capacidad del filtro que le quede, 6 luces = >80% y 1 luz = <10%. Logo Culligan: Enciende cuando agua filtrada no est disponible desde el grifo. Permanece encendido mientras agua filtrada corra desde el grifo. Alarma: Enciende cuando las bateras de la caja de control, los filtros, o la membrana de osmosis inverso deben ser reemplazados. OPERACIN DE LA CAJA DE CONTROL RESET POWER REPLACE BATTERIES REPLACE FILTERS Botn de reinicio de capacidad del filtro. Fuerza: Enciende de color verde al inicio, cuando reinicia la capacidad del filtro, y mientras corra agua filtrada. La luz parpadear por 1 minuto despus de que se cierre el flujo de agua. Reemplazo de Bateras: Enciende de color rojo cuando las bateras para la caja de control deben ser reemplazadas. Reemplazo de Filtros: Enciende de color rojo cuando los filtros tienen menos de 10% de vida segn indica el flujo o el tiempo. Este indicador se reinicia empujando el botn de reinicio por dos segundos. 19 SOLUCIN DE PROBLEMAS FUGAS DE AGUA POR ENTRADA O SALIDA DEL FILTRO/SISTEMA DE OSMOSIS INVERSO:
Una arendala doblada podra estorbar en entrada completa del tubo. Use un destornillador pequeo para asentar la arendala de nuevo, y entonces asegurarse de que el extremo del tubo tenga una cortada cuadrada, y limpia. FLUJO BAJO DE AGUA FILTRADA/EL SISTEMA CAMBIA DE AGUA FILTRADA A AGUA NO FILTRADA AUTOMATICAMENTE:
El flujo bajo quiz no este activando la caja de control. Consulte el manual de su sistema de filtracin para averiguar cmo aumentar el flujo de agua. EL BOTN COMUNICA PERO NO HAY CAMBIO EN EL FLUJO:
Confirme que la vlvula de derivacin est en la posicin cerrada/apuntada hacia abajo. EL BOTN NO COMUNICA SIEMPRE:
Algunos materiales pueden estorbar la seal inalmbrica mas que otros. Intente mover el botn a otra area ubicada ms de cerca a la caja de control. EL AGUA FILTRADA NO SE APAGA: Bateras de poca fuerza en la caja de control pueden causar que el sistema se quede en la posicin de agua filtrada. Se puede emplear la vlvula de derivacin para permitir el flujo de agua no filtrada al grifo mientras se corrija el asunto. Si las fugas de agua persisten, o si hay otras fugas de agua de la caja de control, favor de apagar el suministro de agua. Srvase llamar para ayuda tcnica a 1-800-721-7360. REGISTRO DE PRODUCTO Asegrese de registrar la compra de su producto en lnea dentro de los 30 das a partir de la compra en www.register.culligan.com. 20 GARANTA LIMITADA DE UN AO La garanta se aplica al botn y la caja de batera. La garanta cubre los defectos en el material y la fabricacin por un ao completo desde la fecha original de entrega. Culligan reemplazar cualquier pieza que se considere defectuosa, con las siguientes excepciones: (1) si algn componente de la unidad estuvo sujeto a algn tipo de manipulacin, alteracin o uso inapropiado despus de la entrega, o (2) si haba sido reparado por una agencia no aprobada por Culligan. Culligan no asume responsabilidad alguna por los daos durante el transporte, y en caso de algn reclamo debido a dichos daos, el cliente deber presentar el reclamo ante el transportista. Esta garanta no cubre ningn tipo de gastos de envo, transporte o mano de obra en los que se haya incurrido. La contratacin de un individuo o un servicio para la instalacin o mantenimiento de este producto se hace a la discrecin del comprador y, por lo tanto, cualquier gasto incurrido es responsabilidad del comprador mismo. Este producto ha sido diseado solamente para ser usado como un control de filtracin de agua. La garanta NO cubre daos producidos debido a las temperaturas bajo cero o el aumento repentino de presin de agua. El uso indebido de este producto y sus componentes podra provocar defectos o deterioro no estn cubiertos por la garanta. LA GARANTA SUSODICHA ES EXCLUSIVA Y SUSTITUYE CUALQUIER OTRA GARANTA, EXPRESA O IMPLCITA, YA SEA UNA GARANTA VERBAL O UNA QUE DERIVE DEL USO O LA PRCTICA COMERCIAL, INCLUIDA, DE MANERA SIN LMITE, CUALQUIER GARANTA DE APTITUD O COMERCIABILIDAD. ESTA GARANTA ES EL NICO RECURSO EXCLUSIVO DEL COMPRADOR. BAJO NINGUNA CIRCUNSTANCIA CULLIGAN ASUMIR LA RESPONSABILIDAD POR LA PRDIDA DE GANANCIAS ANTICIPADAS, LOS DAOS ACCIDENTALES, DAOS CONSECUENTES, GASTOS, GASTOS DE TIEMPO DE MANO DE OBRA U OTRO TIPO DE PRDIDAS, SEA POR EL INCUMPLIMIENTO DEL CONTRATO, UNA CONDUCTA ILCITA O CUALQUIER OTRA TEORA, EN RELACIN CON LA COMPRA, LA INSTALACIN, LA REPARACIN O EL FUNCIONAMIENTO DE ESTE PRODUCTO. CULLIGAN NO AUTORIZA A NINGUNA PERSONA A ASUMIR RESPONSABILIDADES U OTORGAR GARANTAS ADICIONALES EN SU NOMBRE EN RELACIN CON ESTE PRODUCTO. Para obtener un servicio conforme a esta garanta, deber devolver cualquier pieza defectuosa a SU COMERCIANTE dentro del plazo de un ao especificado anteriormente. Asegrese de completar el registro de garanta en lnea dentro de los 30 das a partir de la compra y conserve la factura original, la orden de compra o el comprobante de venta, ya que sirven como prueba de la compra para poder realizar una devolucin. 21 Culligan International Company Rosemont, Illinois 60018 www.culligan.com Technical Support MF 8:00AM4:30PM (CST) Ayuda Tcnica disponible de lunes a viernes, de 8:00 A.M. a 4:30 P.M. (CST) 1-800-721-7360 2015 Culligan International Company 01029484 A
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2016-02-25 | 2402 ~ 2480 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2016-02-25
|
||||
1 | Applicant's complete, legal business name |
Culligan International Company
|
||||
1 | FCC Registration Number (FRN) |
0017641739
|
||||
1 | Physical Address |
9399 West Higgins Road
|
||||
1 |
Rosemont, Illinois 60018
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
s******@nemko.com
|
||||
1 | TCB Scope |
A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
V7U
|
||||
1 | Equipment Product Code |
010291CL
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
J******** T******
|
||||
1 | Title |
Regulatory Specialist
|
||||
1 | Telephone Number |
84743********
|
||||
1 | Fax Number |
84743********
|
||||
1 |
j******@culligan.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Bidirectional module | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Limited Single Modular Approval | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Nemko Canada Inc. (Ottawa)
|
||||
1 | Name |
C****** N****
|
||||
1 | Telephone Number |
613-7******** Extension:
|
||||
1 | Fax Number |
613-7********
|
||||
1 |
c******@nemko.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2402.00000000 | 2480.00000000 |