all | frequencies |
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|
manual | photos | label |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
user manual | Users Manual | 3.31 MiB | April 12 2018 | |||
1 |
|
internal photos | Internal Photos | 825.56 KiB | April 12 2018 | |||
1 |
|
external photos | External Photos | 1020.48 KiB | April 12 2018 | |||
1 |
|
label and location | ID Label/Location Info | 152.03 KiB | April 12 2018 | |||
1 |
|
LMA letter | Cover Letter(s) | 515.06 KiB | April 12 2018 | |||
1 | RF Exposure Info | April 12 2018 | ||||||
1 | block diagram | Block Diagram | December 04 2018 | confidential | ||||
1 |
|
confidential letter | Cover Letter(s) | 167.40 KiB | April 12 2018 | |||
1 | operational description | Operational Description | December 04 2018 | confidential | ||||
1 | schematics | Schematics | December 04 2018 | confidential | ||||
1 | Test Report | April 12 2018 | ||||||
1 | Test Setup Photos | April 12 2018 |
1 | user manual | Users Manual | 3.31 MiB | April 12 2018 |
Cat. No. 01029457 Rev. B 11/14/18 DCO # 018577 Installation, Operation, and Service Instructions with Parts Lists CULLIGAN ClearLink Wireless Filtration Control Models from 2018 2018 Culligan International Com pa ny Attention Culligan Customer:
Your local independently operated Culligan dealer employs trained service and maintenance personnel who are experienced in the installation, function and repair of Culligan equipment. This publication is written specifically for these individuals and is intended for their use. We encourage Culligan users to learn about Culligan products, but we believe that product knowledge is best obtained by consulting with your Culligan dealer. Untrained individuals who use this manual assume the risk of any resulting property damage or personal injury. NOTICE Please send any suggestions for improving this manual to productmanuals@culligan.com WARNING! Electrical shock hazard! Prior to servicing equipment, disconnect power supply to prevent electrical shock. WARNING!
If incorrectly installed, operated, or maintained, this product can cause severe injury. Those who install, operate, or maintain this product should be trained in its proper use, warned of its dangers, and should read the entire manual before attempting to install, operate, or maintain this product. Failure to comply with any warning or caution that results in any damage will void the warranty. CAUTION! This product is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction. CAUTION! Children should be instructed not to play with this appliance. CAUTION!
If the power cord from the power supply to the unit looks or becomes damaged, the cord and power supply should be replaced by a Culligan Service Agent or similarly qualified person in order to avoid a hazard. NOTE This system is not intended for use with water that is microbiologically unsafe or of unknown quality without adequate disinfection either before or after the system. NOTE Check with your public works department for applicable local plumbing and sanitation codes. Follow local codes if they differ from the standards used in this manual. To ensure proper and efficient operation of the Culligan ClearLink Pro to your full satisfaction, carefully follow the instructions in this manual. Products manufactured and marketed by Culligan International Company (Culligan) and its affiliates are protected by pat-
ents issued or pending in the United States and other countries. Culligan reserves the right to change the specifications referred to in this literature at any time without prior notice. Culligan, Aqua-Sensor, Tripl-Hull, and SoftMinder are trade-
marks of Culligan International Company or its affiliates. Culligan International Company 9399 West Higgins Road, Suite 1100 Rosemont, Illinois 60018 1-847-430-2800 www.culligan.com 2 Culligan ClearLink Pro 2 Cat. No. 01029457 Installation, Operation and Service Instructions Culligan ClearLink Pro Wireless Filtration Control Models from 2018 Contents Read this Manual First .................................................... 5 Introduction ........................................................................ 5 About this Manual ........................................................... 6 Safe Practices................................................................. 6 Serial Numbers ............................................................... 6 ClearLink Pro .................................................................. 7 ClearLink Connect .......................................................... 7 About Models..................................................................... 7 Drinking Water Connect .................................................. 8 Parts Included: ................................................................ 9 Tools and Materials Required ......................................... 9 Specifications.................................................................. 9 Precautions ..................................................................... 9 Installation ......................................................................... 9 Setting Capacity and TDS Function (All Models) .......... 10 Installation (All Models)................................................. 11 External Flow Switch for a Secondary Outlet ............... 15 Flow Switch 40 Wire Extension Kit (if applicable) ........ 17 Cat. No. 01029457 Leak Sensor Installation ............................................... 17 System Startup
...................................................................................... 18 Button Display Guide .................................................... 21 Control Box Operation .................................................. 22 Pair to Android .............................................................. 23 Pairing to Smartphone ..................................................... 23 Pair to iPhone ............................................................... 25 Viewing Device On Cport To ensure you are able to monitor your device on Cport you must enter your dealer number within the app....... 28 Troubleshooting Guide ................................................. 29 Control Box Lights ........................................................ 29 Troubleshooting ............................................................... 29 Routing Guides ............................................................. 30 Replacement Parts List ................................................... 34 One-Year Limited Warranty ............................................. 35 Index ................................................................................ 36 3 This page intentionally left blank. 4 Culligan ClearLink Pro 4 Cat. No. 01029457 Introduction Read this Manual First Before you operate the Culligan ClearLink systems, read this manual to become familiar with the device and its capabilities. The ClearLink units are certified by WQA against CSA B483.1, NSF/ANSI 372 for low lead requirement, NSF/ANSI 42 and NSF/ANSI 58 for material safety and structural integrity. Model: CulRF-M5 used in devices ClearLink PB, ClearLink D-WiFi and ClearLink D. WM-N-BM-30 used in device ClearLink D-WiFi. Contains FCC ID: V7U-010330CL, IC: 6510B-010330CL, FCC ID: COF-WMNBM30 and IC: 10293A-WMNBM30. This device complies with part 15 of the FCC Rules subject to the following two conditions:
(1) This device may not cause harmful interference (2) This device must accept all interference received including interference that may cause undesired operation. Le prsent appareil est conforme aux CNR Innovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil nedoit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. This device complies with Health Canadas Safety Code. The installer of this device should ensure that RF radiation is not emitted in excess of the Health Canadas requirement. Cet appareil est conforme avec Sant Canada Code de scurit 6. Le programme dinstallation de cet appareil doit sassurer que les rayonnements RF nest pas mis au-del de Iexigence de Sant Canada. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Les changements ou modifications non expressment approuvs par la partie responsable de la conformit pourraient annuler lautorit de lutilisateur utiliser cet quipement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Increase the separation between the equipment and receiver. Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Innovation, Science and Economic Development Canadas licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR Innovation, Sciences et Dveloppement conomique Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage, et (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. This Class B digital apparatus complies with Innovation, Science and Economic Development Canada ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Innovation, Sciences et Dveloppement conomique Canada. Cat. No. 01029457 Introduction 5 About this Manual This manual:
Familiarizes the operator with the equipment Explains installation and setup procedures Explains the various modes of operation Gives specifications and troubleshooting information This publication is based on information available when approved for printing. Continuing design refinements could cause changes that may not be included in this publication. Safe Practices Throughout this manual there are paragraphs set off by special headings. Notice Notice is used to emphasize installation, operation or maintenance information which is important, but does not present any hazard. For example, NOTICE Caution Caution is used when failure to follow directions could result in damage to equipment or property. For example, The nipple must extend no more than 1 inch above the cover plate. CAUTION! Disassembly while under water pressure can result in flooding. Warning Warning is used to indicate a hazard which could cause injury or death if ignored. For example, WARNING! Electrical shock hazard! Unplug the unit before removing the timer mechanism or cover plates!
The CAUTION and WARNING paragraphs are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution, and careful attention are conditions which cannot be built into the equipment. These MUST be supplied by the personnel installing, operating, or maintaining the system. Be sure to check and follow the applicable plumbing codes and ordinances when installing this equipment. Local codes may prohibit the discharge of acid or caustic solutions to drain. An extra solution tank should be used to neutralize the solution before discharging to drain. Use protective clothing and proper face or eye protection equipment when handling chemicals or power tools. Serial Numbers The serial number is located on the back of the control box. This publication is based on information available when approved for printing. Continuing design refinement could cause changes that may not be included in this publication. NOTE Do not remove or destroy the serial number. It must be referenced on request for warranty repair or replacement. 6 Culligan ClearLink Pro 6 Cat. No. 01029457 About Models NOTE Illustrations are for overview purposes only, for RO installations an air gap and RO tank is needed. ClearLink Pro The ClearLink PRO is a first-to-market wireless control system that allows you to get Culligan filtered water from your main faucet. Installing an RO system used to required a dedicated faucet, which meant drilling a hole or losing a soap dispenser. Now you can use your existing faucet to wash vegetables with your sprayer, fill pots for cooking, or simply enjoy a glass of filtered water. Figure 1. ClearLink Connect The ClearLink Connect takes the ease of using your current faucet and pairs it with the technology of staying connected anywhere. This Wi-Fi enabled ClearLink keeps all of the same functionality of the ClearLink Pro but adds the ability to connect to the Culligan Connect App. Track water consumption, contaminants being removed, filter / membrane life and if a leak is detected from anywhere, using the convenience of an app.
+WiFi Capable
+Leak Sensor Cat. No. 01029457 About Models 7 Figure 2. Drinking Water Connect NOTE Separate connections for filtered and unfiltered water. The Drinking Water Connect allows drinking water customers to stay connected to their system anywhere. This Wi-Fi enabled product can be added to virtually any household drinking water installation and adds the ability to connect to the Culligan Connect App. Track water consumption, contaminants being removed, filter / membrane life and if a leak is detected from anywhere, using the convenience of an app.
+ WiFi Capable
+ Leak Sensor Figure 3. 8 Culligan ClearLink Pro 8 Cat. No. 01029457 Installation Parts Included:
Remote Button (not available with Drinking Water Connect) Control Box Battery Box 3/8 x 1/4 Tube Adapter Mounting Screws Air Gap (not available with Drinking Water Connect) Tools and Materials Required D Batteries x4 AAA Batteries x2 Screwdriver Adjustable Wrench Towels Pan or Bucket Specifications Pressure Range: 30-120 psi (207-827 kPa) Temperature Range: 40-100 F (4.4 - 37.7 C) Precautions WARNING! Follow all precautions indicated in the manual provided with the Culligan water treatment system. WARNING! For systems using a booster or distribution pump, the pressure of the treated water cannot exceed the pressure of the cold water supply. WARNING! Reducing the Booster pump pressure below incoming pressure will allow the proper operation of the ClearLink. WARNING! For cold water use only. Do not use on hot water line. CAUTION! Control box must be protected against freezing temperatures, frost, snow, sleet and ice. Exposure to these can produce cracks and product failures. CAUTION! The Filter/RO should be flushed before installing into the system to ensure the proper operation of the ClearLink. CAUTION! This product has a limited service life. We recommend that a record be kept regarding the date of install and any other performed maintenance. Because of the products limited service life and to prevent costly repairs or possible water damage, we strongly recommend that the control box be replaced every ten years. After prolonged periods of non-use (such as during a vacation) it is recommended that the system be flushed thoroughly. Let the filtered water run for 5-6 minutes before using. The ClearLink estimates filter life based on flow and time. Changes in taste, odor, color and/or flow of the filtered water could indicate that the filter(s) should be replaced. Make certain that installation complies with all state and local laws and regulations. Cat. No. 01029457 Installation 9 Setting Capacity and TDS Function (All Models) NOTE Set capacity and TDS function before starting installation. NOTE To access the dip switches for setting capacity and TDS function, open the control box by removing the three screws in the rear cover. ON = Enabled Find the dip switches on the front of the circuit board. SW2 and SW3 set the time and capacity for the filter reminder. SW1: OFF = Disabled Enables/Disables the TDS function (Enable only for RO systems). The system will measure the difference between the feed and product water to determine if the RO is working. If installing an RO system with a Mineral Boost cartridge, this feature may need to be disabled so that the alert indicator does not illuminate prematurely for RO membrane replacement. SW2: OFF = 500 gallons SW3: OFF = 180 days SW6 is used for production testing and should be left in the off position. ON = 1,000 gallons ON = 365 days ON S W 1 S W 2 S W 3 S W 6 Figure 4. Dip Switches 10 Culligan ClearLink Pro 10 Cat. No. 01029457 Installation (All Models) NOTE If using an external flow switch, install the external flow switch before installing the ClearLink. See External Flow Switch for a Secondary Outlet on page 15 for instructions. NOTE Refer to the manual provided with your filter/RO for installation instructions specific to that system. NOTE Some installations may require adapters and fittings not included with the product. Review the manual and your installation before beginning. NOTE Consult your local plumbing codes and install accordingly. 1. Turn off both hot and cold water shut-off valve then turn on the kitchen faucet and allow all water to drain from line. Figure 5. 2. Disconnect the cold water line from the cold water shut-off valve. NOTE If rigid plumbing pipe (metal or plastic) is used, you may need to shorten the pipe using a hacksaw or pipe cutter to accommodate the control box. Cat. No. 01029457 Figure 6. Installation 11 3. Connect the control box to the cold water shut-off valve and the water line to the facet as shown. Culligan recommends 1/2 - 3/4 additional turns past finger-tight. CAUTION! The stationary hex nut on the outlet of the ClearLink should not be used to over-tighten the hose fitting. NOTE The control box must be in a vertical position. NOTE If space does not allow for mounting the control box onto the valve, it can be mounted on a wall and connected using flexible lines. (purchased separately). Figure 7. Figure 8. 4. Connect the inlet on the RO/Filter system to the port marked RO/Filter
. Wet the end of the plastic tubing with water and push it into the quick connect fitting adapter approximately 5/8 until it stops. NOTE All filters and RO membranes should be flushed before connecting any ClearLink device to the filtration/RO system. NOTE This connection is plugged for remote system installations (Water supply is not the same as the sink such as basement installations). This port is normally plugged when installing the filtration/RO system in a location other than the kitchen cabinet. NOTE Use the supplied adapter if your system uses a 1/4 tube. 12 Culligan ClearLink Pro 12 Cat. No. 01029457 5. Connect the product water outlet on the RO/Filter system to the port marked RO/Filter . Wet the end of the plastic tubing with water and push it into the quick connect fitting adapter until it stops. NOTE This is the line that would normally go to your dedicated faucet. NOTE Connect the tank and/or post filter in this line if required for your filter/
RO system. Tank Figure 9. NOTE Steps 6 through 8 are only for RO installations using an air gap. NOTE NOTE NOTE Check and adhere to local plumbing codes for Air Gap installation. If your filtration system is not an RO, skip to System Startup. Install the drain connection to the drain plumbing according to the manual provided with your RO system. AIR GAP 6. Mount the air gap device as near to counter top as possible and in a vertical orientation. WARNING!
Install the air gap as high as possible using air gap installation bracket. WARNING! Failure to mount the air gap device vertically will cause it to leak water. Figure 10. Cat. No. 01029457 Installation 13 7. Connect the drain line coming from the RO system to the 1/4 connection of the air gap device. NOTE Drain line adapters are available through Culligan Marketplace that can be used when considering the best drain line connection. Figure 11. Figure 12. 8. Connect the 3/8 fitting of the air gap device to the connection on the drain plumbing. NOTE If the customer has a garbage disposal, connect the RO drain line coming from the air gap to the auxiliary port
(removable plug where a dishwasher drain is typically hooked up) rather than downstream of the disposal. The high flow rate from a disposal sucking water from a clogged sink will send water up and out of the air gap. Tank Tank 14 Culligan ClearLink Pro 14 Cat. No. 01029457 External Flow Switch for a Secondary Outlet For use with ClearLink Connect and as an optional accessory on the Drink Water Connect. No available for use with ClearLink PRO. See Routing Guides on page 30. NOTE External flow switch must be installed after the post filter. NOTE If the inlet of the refrigerator (or similar) requires 1/4 tubing, the reducing stem should be installed as close to the refrigerator as possible to reduce the pressure drop caused by smaller diameter tubing. Tank To Secondary Outlet, such as a refrigerator Figure 13. Cat. No. 01029457 Installation 15 Flow Switch Wiring NOTE The standard length of the flow switch wire is 3. If needed, a 40 wire extension is available separately. 10. Reinsert screws. 1. Remove Screws 2. Remove the back cover. 9. Reinsert the back cover 5. Push on orange tab, insert wire, then let go of orange tab. NOTE Gently pull on wires to confirm that they are fully inserted. 7. Reinsert slider. 6. Reinsert the manifold with PCB. 3. Remove slider. 4. Remove manifold with PCB. 8. Lay the wire into the groove. Figure 14. Flow Switch Wiring 16 Culligan ClearLink Pro 16 Cat. No. 01029457 Flow Switch 40 Wire Extension Kit (if applicable) 3. Using wire strippers, strip a 1/4 of insulation from the wire. NOTE Stripping too much of the wire can cause the wires to fray, which can cause the unit to malfunction over time. Stripping too little of the wire can prevent the ends from being able to have proper contact with the connector on the PCB. 1. Connect flow switch wires to the extension using the supplied crimp connectors. 4. Insert wires into the connector on the PCB, see Figure 14. 2. Cut wire to required length. Figure 15. Leak Sensor Installation NOTE For use with ClearLink Connect and Drinking Water Connect. Not available for use with ClearLink Pro. 1. Plug in Leak Sensor Cat. No. 01029457 Installation 17 Figure 16. System Startup 1. Confirm that the bypass valve is in the closed position (pointed down). BYPASS Figure 17. 2. Turn on the cold water supply and check for leaks. If it leaks, refer to Troubleshooting on page 29. Tank Figure 18. 18 Culligan ClearLink Pro 18 Cat. No. 01029457 3. Install four D batteries (not included) into the battery box and plug into the jack on the bottom of the control box. NOTE The control box will beep and flash the power light when powering up. NOTE AC adapter (01029455) can also be used where a non-switch-controlled outlet is available. D Figure 19. 4. Place a damp paper towel to the pins. This should cause the leak sensor light on the control box (page 18) to flash, the unit to beep and the Culligan Connect App (if setup) to notify the user of the error. 5. Dry pins and place at the lowest point in the cabinet or under the ClearLink Control Box. Figure 20. Cat. No. 01029457 Installation 19 6. Use the provided screw to hang the battery box on the side of the cabinet. Figure 21. 7. Install two AAA batteries (not included) into the remote button. CAUTION!
If the button gets wet, remove the batteries. Air dry immediately!
Replace button, if corrosion appears and/
or button malfunctions. 20 Culligan ClearLink Pro 20 Cat. No. 01029457 Figure 22. 8. Turn on the faucet to full cold and push the button to activate the system. NOTE All filters and RO membranes should be flushed before connecting any ClearLink device to the filtration/RO system. NOTE The blue capacity lights should appear if the button and control box are communicating. NOTE The button can be turned off with a second push or by turning off the faucet. Figure 23. Button Display Guide Filter Capacity Lights: Shows from 1-6 lights depending on filter capacity remaining, 6 lights
=> 80% and 1 light =<10%. Culligan Logo: Flashes when treated water is not available from the faucet. Stay solid while treated water is being dispensed from the faucet. Alert Indicator: Illuminates when the control box batteries need replacing, filters need replacing, membrane needs replacing or if leak is detected on connected versions. Figure 24. Cat. No. 01029457 Installation 21 Control Box Operation ClearLink Reset Button for filter capacity. Power: Flashes green at power up, filter capacity reset, and while dispensing filtered water. Continues to flash for 1 minute after the flow of filtered water has stopped. Replace Batteries: Flashes red when the batteries for the control box need to be replaced. This indicator automatically clears when new batteries are detected. Replace Filters: Flashes red when the filters have less than 10% of their life remaining due to flow or time. This indicator is reset by pressing the reset button for three seconds. Replace RO Membrane: Flashes red when the treated water has a TDS level greater than 25%
of the untreated water. This indicator will automatically reset when low TDS water is detected. ClearLink Connect and Drinking Water Connect Figure 25. Reset Button for filter capacity. Power: Flashes green at power up, filter capacity reset, and while dispensing filtered water. Continues to flash for 1 minute after the flow of filtered water has stopped. Replace Batteries: Flashes red when the batteries for the control box need to be replaced. This indicator automatically clears when new batteries are detected. Replace Filters: Flashes red when the filters have less than 10% of their life remaining due to flow or time. This indicator is reset by pressing the reset button for two seconds. Replace RO Membrane: Flashes red when the treated water has a TDS level greater than 25% of the untreated water. This indicator will automatically reset when low TDS water is detected. Leak Detected: Flashed red when the leak sensor has detected water. WiFi Enabled: Flashes blue when the WiFi is connected to the control box. Figure 26. WiFi Reset Button:
Press with paper clip. One short press forces data upload. Holding for 10 seconds will initiate device pairing. 22 Culligan ClearLink Pro Figure 27. 22 Cat. No. 01029457 Pairing to Smartphone Pair to Android 1. Go to Google Play Store to download and install Culligan Connect app to the customers smartphone. 2. Go to phone settings and connect to your local WiFi network. 3. Launch Culligan Connect App. 4. Create a new account by selecting Create an account. A link will be emailed to you that must be clicked via your device to finalize setup. Once finalized, login. Figure 28. Figure 29. 5. To activate device and place it into pairing/registration mode, use a paper clip to press and hold WiFi Reset on the Control Box for 10 seconds until blue light changes from flashing to solid. Cat. No. 01029457 Pairing to Smartphone 23 6. Start system setup process. 7. Search for Culligan device and select it once found. Figure 30. Figure 31. 24 Culligan ClearLink Pro 24 Cat. No. 01029457 8. Select your local WiFi network, enter WiFi password (if applicable) and connect device. 9. Your App and device will now pair. 10. You are now connected and ready to take control of your water!
Figure 32. NOTE Only one account will work per connected ClearLink. Pair to iPhone 1. Go to Apple app store Store to download and install Culligan Connect app to the customers smartphone. 2. Go to phone settings and connect to your local WiFi network. 3. Launch Culligan Connect App. 4. Create a new account by selecting Create an account. A link will be emailed to you that must be clicked via your device to finalize setup. Once finalized, login. Cat. No. 01029457 Pairing to Smartphone 25 Figure 33. 5. To activate device and place it into pairing/registration mode, use a paper clip to press and hold WiFi Reset on the Control Box for 10 seconds until blue light changes from flashing to solid. 6. Start system setup process. Figure 34. Figure 35. 26 Culligan ClearLink Pro 26 Cat. No. 01029457 7. Open the iPhone settings/WiFi 8. Search for Culligan device and select it once found. Figure 36. 9. iOS 11 or newer:
- You might see a popup Error Opening Page - if so, select OK.
- Select Done in the upper right corner of the next screen.
- This returns you to the settings/Wi-Fi screen, where the Culligan device will be selected.
- Manually go back to the app and select the blue Connect to Device button at the bottom of the screen. Figure 37. 10. Select your local WiFi network, enter WiFi password (if applicable) and connect device. 11. Your App and device will now pair. 12. You are now connected and ready to take control of your water!
NOTE Only one account will work per connected ClearLink. Figure 38. Cat. No. 01029457 Pairing to Smartphone 27 Viewing Device On Cport To ensure you are able to monitor your device on Cport you must enter your dealer number within the app. 1. Select settings icon in upper corner of home screen. 2. Select Settings at bottom of the screen. Figure 41. Figure 40. 3. Select Dealer tab and enter your dealer id # and tap Change Dealert. Figure 39. 28 Culligan ClearLink Pro 28 Cat. No. 01029457 Troubleshooting Guide Problem Leaks at filter/RO Inlet or outlet connection Low filtered water flow/system returns to unfiltered flow automatically:
Button is communicating, but no change in flow. Button communication is intermittent. Filtered water flow wont turn off. WiFi connection issues Pairing issues Control Box Lights Audible Beep 3 Beeps during Power up 1 beep per minute when water is running and 1 beep when the water is turned off. 1 beep per minute when water is running and 1 beep when the water is turned off. 1 beep per minute when water is running and 1 beep when the water is turned off. 1 beep per minute when water is running and 1 beep when the water is turned off. Troubleshooting Solution A rolled o-ring can block the tube from fully inserting. Use small screw driver to reseat the o-ring and then confirm that the end of the tubing has a clean, square cut. Low flow rates may not activate the control box electronics. Refer to your system manual to trouble shoot a low flow condition. Confirm that the bypass valve is in the down/closed position. Some materials may block the wireless signal more than others. Try moving the button to an area on the counter that is closer to the under-sink control box. Low batteries for the control box can cause the system to be stuck in the filtered position. The bypass valve can be used to allow unfiltered water flow to the faucet while the issue is being corrected. Call Technical Service Line at 800-333-9047. Select option 6 for assess to the support line, then option 1 for onsite pairing support Light Green (Top Window) Red (Top Window) Means Power On and performing operations Option 1: Replace D Batteries in Control Box Option 2: Use A/C Adapter instead of D Batteries Yellow (Second Window) Reached Capacity in Gallons/Days; Replace Red (Second Window) Filter High TDS; Replace Membrane Red (Third Window) Leak Detected Blue (Bottom Window) WiFi Enabled and Paired Cat. No. 01029457 Troubleshooting 29 Routing Guides ClearLink Connect: Under Sink Install with Secondary Line Post Filter Flow Switch Tank Figure 42. KITCHEN BASEMENT 30 Culligan ClearLink Pro 30 Cat. No. 01029457 ClearLink Connect: Remote Install with Secondary Line KITCHEN BASEMENT Flow Switch Wire To Drain Flow Switch Post Filter Tank Figure 43. Cat. No. 01029457 Troubleshooting 31 Drinking Water Connect: Under Sink Install with Secondary Line To Drain Post Filter Tank KITCHEN BASEMENT Figure 44. 32 Culligan ClearLink Pro 32 Cat. No. 01029457 Drinking Water Connect: Remote Install with Secondary Line KITCHEN BASEMENT Cap outlet or run to wash tub faucet or similar To Drain Post Filter Tank Figure 45. Cat. No. 01029457 Troubleshooting 33 Replacement Parts List Item Part Number 1 2 3 5 4 A B C D E F G 1 2 3 4 5
*
*
*
*
*
01029472 01029473 01029474 01033051 01033052 01033053 01033121 01029450 01029452 01029453 01029454 01029449 01033035 01033034 01033128 01030130 01033141 01029455 01033130 01033170 Kit Description ClearLink Pro, Chrome ClearLink Pro, Brushed Nickel ClearLink Pro, Oil Rubbed Bronze ClearLink Connect, Chrome ClearLink Connect, Brushed Nickel ClearLink Connect, Oil Rubbed Bronze Drinking Water Connect A, B, C, D, E, F Remote Button A, D B, E C, F A, B, C G D, E, F A, B, C, D, E, F, G A, B, C, D, E, F D, E, F D, E, F Remote Button, Trim Ring, Chrome Finish Remote Button, Trim Ring, Brushed Nickel Finish Remote Button, Trim Ring, Oil Rubbed Bronze Control Box, ClearLink Pro Control Box, Drinking Water Connect Control Box, ClearLink Connect Battery Box, D Batteries Air Gap Air Gap Mounting Bracket AC Adapter (optional) External Flow Switch with 3 Wires**
External Flow Switch, 40 Wiring Extension Kit (optional) 01033129 D, E, F, G Leak Sensor**
*Not Shown
**Not designed to work with ClearLink Pro. 34 Culligan ClearLink Pro 34 Cat. No. 01029457 One-Year Limited Warranty This warranty applies to the button, control box and battery box. This warranty covers defects in material and workmanship only for 1 full year from the original date of delivery. Culligan will replace any part which in Culligans opinion is defective, unless: (1) any part of the unit has been subjected to any type of tampering, alteration, or improper use after delivery, or (2) it has been repaired by anyone not approved by Culligan. This product has been designed solely for use as a water filtration control. It is NOT warranted against freezing or surges in water pressure, and neither this product nor its parts is warranted against defects or deterioration caused by uses for which this product was not expressly intended. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, WHETHER ORAL OR ARISING BY USAGE OF TRADE OR COURSE OF DEALING, INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF FITNESS OR MERCHANTABILITY. THIS WARRANTY IS THE PURCHASERS SOLE AND EXCLUSIVE REMEDY, IN NO EVENT SHALL CULLIGAN BE LIABLE FOR ANY ANTICIPATED OR LOST PROFITS, INCIDENTAL DAMAGES, CONSEQUENTIAL DAMAGES, COSTS, TIME CHARGES OR OTHER LOSSES, WHETHER BASED ON BREACH OF CONTRACT, TORTIOUS CONDUCT OR ANY OTHER THEORY, INCURRED IN CONNECTION WITH THE PURCHASE, INSTALLATION, REPAIR OR OPERATION OF THIS PRODUCT. CULLIGAN DOES NOT AUTHORIZE ANYONE TO ASSUME FOR IT ANY LIABILITY OR TO MAKE ON ITS BEHALF ANY ADDITIONAL WARRANTIES IN CONNECTION WITH THE FILTER HOUSING OR ANY PART THEREOF. Cat. No. 01029457 Replacement Parts List 35 Index A About Models 7 About this Manual 6 Alert Indicator 21 Android 23 B Button 21 Button Display 21 C Capacity 10 ClearLink 22 ClearLink Connect 7, 22, 30, 31 ClearLink Pro 7 Contents 3 Control Box 22 Control Box Lights 29 Control Box Operation 22 Cport 28 Culligan Logo 21 D Drinking Water Connect 8, 22, 32, 33 E External Flow Switch 15 F Filter Capacity Lights 21 Flow Switch 15, 16, 17 I Install 30, 31, 32, 33 Installation 9, 11 Introduction 5 iPhone 25 L Leak Sensor 17 M Materials 9 Models 7 O Outlet 15 P Pairing 23 Pairing to Smartphone 23 Pair to Android 23 Pair to Cport 28 Pair to iPhone 25 Parts 9 Parts List 34 Power 22 Precautions 9 R Remote Install 31, 33 Replace Batteries 22 Replace Filters 22 Replacement Parts List 34 Replace RO Membrane 22 Reset Button 22 Routing Guides 30 S Safe Practices 6 Serial Number 6 Serial Numbers 6 Setting Capacity 10 Specifications 9 Startup 18 Switch 16 Switch Wiring 16 System Startup 18 T TDS 10 TDS Function 10 Tools 9 Troubleshooting 23, 29 Troubleshooting Guide 29 U Under Sink Install 30, 32 W Warranty 35 Wire Extension Kit 17 Wiring 16 36 Culligan ClearLink Pro 36 Cat. No. 01029457 Notes Cat. No. 01029457 Index 37 This page contains materials and DCO in for ma tion. IT DOES NOT PRINT AS PART OF THE DOC U MENT!
Materials & Description: ClearLink Pro Installation & Operating Guide PN 01029457 Size:
Color:
Stock:
8.5 x 11 Black Ink, 2 sided Front (2 sided) & Back (Blank) Covers on 110# White Index Inside on 20# white Other:
Collate Tape Bind, Black Down the 11 left side LET A A1 A2 B Change NEW ART CREATED FCC corrections FCC/IC Changes New Models, FCC/IC Update By Motiva/JT Appvd AC/BM JT JT JT/VP JT JT AC DCO 016500 016500 016500 018577 Date 10/12/15 12/07/15 02/05/16 11/14/18 38 Culligan ClearLink Pro 38 Cat. No. 01029457
1 | LMA letter | Cover Letter(s) | 515.06 KiB | April 12 2018 |
better water. pure and simple?
compliance of the final assembly with CFR 47,15.249.
(h) The module must comply with RF exposure requirements Yes, the module will be used by Culligan Internation for final assemblies used only in Mobile rf exposure configurations. This filing contains evidence of compliance with rf exposure rules for mobile configuration.
* Please provide a detailed explanation if the answer is No. a Name: Jennifer Talley Title: Regulatory Specialist Yours err ae
1 | confidential letter | Cover Letter(s) | 167.40 KiB | April 12 2018 |
better water. pure and simple, November 13, 2018 Nemko Canada Inc. 303 River Road Ottawa, ON Canada K1V 1H2 REQUEST FOR CONFIDENTIALITY Name of Applicant: Culligan International Address: 9399 West Higgins Road, Suite 1100 City: Rosemont Country: USA FCC ID: V7U-010330CL IC ID: 6510B-010330CL We would like to request non-disclosure and confidential treatment of the following documents regarding this submission. Pursuant to Sections 0.457 and 0.459 if the commissions rules, and Industry of Canada Regulations, we hereby request the following documents be held under long tern confidentiality:
Block Diagrams Schematics Bill of Materials Operating/Technical Descriptions PON Dated:_ 11/13/2018 Printed: Jennifer Talley Title:___ Regulatory Specialist
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2018-12-04 | 2463 ~ 2463 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2018-12-04
|
||||
1 | Applicant's complete, legal business name |
Culligan International Company
|
||||
1 | FCC Registration Number (FRN) |
0017641739
|
||||
1 | Physical Address |
9399 West Higgins Road Suite 1100
|
||||
1 |
9399 West Higgins Road
|
|||||
1 |
Rosemont
|
|||||
1 |
United States
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
s******@nemko.com
|
||||
1 | TCB Scope |
A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
V7U
|
||||
1 | Equipment Product Code |
010330CL
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
J****** T******
|
||||
1 | Title |
Regulatory Specialist
|
||||
1 | Telephone Number |
84743********
|
||||
1 | Fax Number |
84743********
|
||||
1 |
j******@culligan.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | Wireless Filtration Control | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Limited Single Modular Approval | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
Nemko USA, Inc. - San Diego EMC Division
|
||||
1 | Name |
C****** N********
|
||||
1 | Telephone Number |
613-7********
|
||||
1 |
c******@nemko.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | 2463.00000000 | 2463.00000000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC