HYTRONIK INDUSTRIAL LIMITED Room D, 10/f, Tower A, Billion Center, 1 wang Kwong Road, Kowloon Bay, Kowloon, Hongkong T: 00852-35197525 F: 00852-30116936 E: info@hytronik.com CHINA FACTORY 3rd Floor, block C, complex building, 155#, Bai'gang road south, Bai'gang village, Xiao Jin Kou town, Huicheng district, Huizhou 516023 Tel:86-752-2772020 F:86-752-2777877 E: info@hytronik.com W:www.hytronik.com INSTRUCTION MANUAL FOR RF WIRELESS SENSOR DETACHED VERSION, MODEL NO.: HN020-01V / HN021-01V / HN022-01 Technical Specifications PRODUCT TYPE:
Microwave Motion Sensor OPERATING VOLTAGE:
12VDC/50mA HF SYSTEM:
DETECTION ANGLE:
5.8GHz CW radar 30 ~ 150 POWER CONSUMPTION:
<1W DETECTION RANGE (DxH):
Max. 16 x 12m HOLD TIME:
30s ~ 30min. DAYLIGHT SENSOR:
2 ~ 500Lux; disable STAND-BY PERIOD:
STAND-BY DIMMING LEVEL:
0s, 10s ~ 1h, +
10% ~50%
MOUNTING:
WORKING TEMP.:
MODEL:
Indoors, ceiling & wall mounted
-20 ~ +60 HN020-01V Microwave / constant illumination HN021-01V Microwave / constant illumination+ RF(868MHz) HN022-01V Microwave / constant illumination+ RF (UL 915MHz) 21.45 6.80 0 6 Microwave mount a Silica gel soft b 1 Ceiling mo unting (m) 8 7 6 5 4 123 1 2 3 4 5 6 7 8 Wall mounting (m) 4 6 8 10 12 14 16 18 20 2 Detection Pattern
) m
t h g i e h 3 6 9 12 15
) m
t h g i e h 8 6 4 2 2 4 6 8 high sensitivity area low sensitivity area high sensitivity area low sensitivity area SECTION 1 TYPICAL APPLICATIONS Typical Applications A ULTRANIK HF motion detector Daylight Harvest The motion detector can turn on the light based on mo vement. With this detector built in, light is automatically on when needed and dimmed to preset level before it is totally off. 1 2 The light keeps off during daytime even when movement is detected. (Ambient lux level is above pres et daylig ht threshold) With movement and insuff icien tambient lux level, the light is triggered on 100% by the detector. The sensor highbay turns on at full or dims to maintain the lux level. The light output regulates according to level of natural light available
...... 3 4 If there is no more movement, the light dims to stand-by dimming level a fter hold-time. The light turns off automatically after stand-by time. 2 B For staircase and corridor (master and slave) slave master 1 Off Off Off Off Off Off Off Off 10%
100%
100%
100%
Corridor slave Off Off Off Off master Off 10%
100%
100%
100%
100%
100%
Corridor While the 1st sensor detects motion on the 1st floor, it switches the light on at 100% and sends signal to all slave units. All slaves on the 1st floor turn on and the sensor highbay on the 2nd floor switches on at stand-by level. The person walks to the 2nd floor, the 2nd Sensor highbay switches the light on at 100%. All slaves on the 2nd floor turn the light on and the Sensor highbay on the 3rd floor switches on at stand-by level. slave Off Off master 10%
3 slave master 100%
100%
100%
100%
100%
100%
100%
100%
100%
100%
10%
10%
10%
10%
10%
10%
Off Off Off Corridor Corridor The person walks to the 3rd floor, the 3rd sensor highbay switches the light on 100%. All slaves on the 3rd floor turn the light on and the Sensor highbay on the 4th floor switches onat stand-by level. Meanwhile, the lights on the 1st floor are dimmed to stand-by level after hold-time. The person walks to the 4th floor, the 4th sensor highbay switches the light on at 100%. All slaves on the 4th floor turn the light on Meanwhile, all sensors on the 1st floor turn the light off after stand-by period, and all lights on the 2nd floor dim to stand-by level after hold-time. SECTION 2 REMOTE CONTROL Permanent ON/OFF [ button ]
Press button ,to select permanent ON or permanent OFF mode.
* Press button / to resume automatic operation. The mode will change to AUTO Mode after power failure. 1 1 2 4 2 2 RESET[ button ]
Press button , all settings go back to the default settings:
Detection range: 100% Hold time: 1min Stand-by period: 5min Stand-by dimming level: 20% Daylight sensor: LUX disable Shift [ button ]
Press button , the LED on the top left corner will ash to All values / settings in RED are valid for 20 seconds. 3 3 indicate mode selection. 4 4 Auto Mode [ button ]
Press button to initiate automatic mode. The sensor starts working and all settings remain as before the light was switched ON/OFF. Semi-auto Mode [ button & ]
1. Press button Shift (the red LED is on for indication), 2. press button to initiate semi-auto mode. The fixture is manually on by push-switch and automatically off in semi-auto mode. 3 3 4 4 1 3 7 9 Power output [ button ]
Press button , the light output shifts between 80% and 100%. Note: the function of Sensor off and Twilight are disabled. 5 5 Brightness +/- [ button ]
Press button to adjust the light brightness between 10%~100% . 6 6 4 h h
& A 4 h 7 Scene prog. [ zone ] (One-key-commissioning) 1. Press button start to program. 2. Select the buttons in Detection range, / Daylight hreshold, Hold time, Stand-by time, Stand-by dimming level to set all parameters. 13 10 11 12 9 8 HRC-11 Note: the red LED indicator flash one time when RC receives signal successfully 3 2 4 4 2 5 6 8 10 11 12 13 14 3. Press button Memory to save all the settings programmed in the remote control. 4. Press button Apply to set the settings to each sensor unit(s). For example, to pre-set detection range 100%, daylight threshold Disable, hold time 5min, stand-by time +, stand-by dimming level 30%, the steps should be as follows: Press button Start, button 100%, Disable, Shift, to the sensor unit(s) and pressing Apply, all settings are passed on the sensor(s). 11 5min, Shift, +, 30%, Memory. By pointing 12 10 13 8 7 3 7 3 7 Detection range [ zone ]
Press buttons in zone to set detection range at 100% / 75%/ 50% / 10%. 8 8 Daylight threshold [ zone ]
Press buttons in zone to set the daylight sensor at 2Lux / 10Lux / 50Lux / 100Lux / 300Lux / 500Lux or Disable. Note: To set daylight sensor at 100Lux / 300 Lux / 500Lux, p ress button Shift at rst. 9 9 3 Ambient daylight threshold [ button ]
1. Press button Shift, the red LED is on for indication. 2. Press button ,the ambient lux level is sampled and set as the new daylight threshold. 3 10 10 11 Hold time [ zone ]
Press buttons in zone to set the hold time at 2s / 30s / 1min / 5min / 10min / 15min / 20min / 30min. Note: 1. To set hold-time at 30s / 5min / 15min / 30min, press button Shift at rst. 2. 2s is for testing purpose only, stand-by period and daylight sensor settings are disabled in this mode.
*To exit from Test mode, press button or anybutton in zone . 11 11 3 2 12 Stand-by time [ zone ]
Press buttons in zone to set the stand-by period at 0s / 10s / 1min / 5min / 10min / 30min / 1h / +. Note: 0s means on/off control; + means bi-level control, 100% on when motion is detected, and remains at the stand-by dimming level when no presence is detected after hold-time. 12 Stand-by dimming level [ zone ]
Press buttons in zone to set the stand-by dimming level at 10% /20% / 30% / 50%. Note: 24h / 12h / 4h / 30s are disabled. 13 13 Dual tech & RF mode [ zone ]
1. HF, PIR, HF+PIR, HF/PIR are disabled. 2. For RF grouping, please see below. 14 RF grouping Short press Learn/Erase button on RC to activate pairing mode, and the receiver unit will flash once every second for 3min. Note: the unit can only pair up to 30 units. Short press Transmit button on RC, the commander unit (master unit) will flash one time to send the transmission signal. Upon receiving the transmission signal, the receiver unit (slave unit) will rapidly flash 3 times in 1s to indicate the success of pairing. Repeat this step to pair more units. One more short press on Learn/Erase button to the receiver unit to complete the pairing process, the receiver unit will quit the pairing mode. Note:
Press button RX100%, the light on receiver unit is 100% on upon receiving RF on signal; Press RX STBY% button, the light(s) goes to preset stand-by dimming level directly.`
Erase:
Long press Learn/Erase button for 3s to the sensor unit. The red LED indicator rapidly flash for about 5s. all commands it has received before will be erased. Sensor setting go back to default setting as followed, after press reset:
Detection range: 100%
Hold time: 5min Stand-by time: 10min Stand-by dimming level: 10%
Daylight threshold: 300LUX Red LED indicator is on for 3min Short press Learn
/Erase button The receiver unit (slave unit) The red LED indicator flash one time. The commander unit (master unit) Short press Transmit button The red LED indicator flash rapidly when RF signal is received The receiver unit (slave unit) Red LED indicatoron in on Short press Transmit button Ste p 1 Ste p 2 Ste p 3 The receiver unit (slave unit) SECTION 3 TROUBLESHOOTING MALFUNCTION CAUSE REMEDY CAUSE REMEDY Incorrect daylight threshold setting Adjust daylight threshold setting The fixture does not light up Faulty fixture No power supply Replace fixture Check power to sensor The fixture is always on Continous movement in the detection zone Check detection area setting The fixture is on when it should not Sudden change in temperature due to weather (wind, rain, snow) or air expelled from fans, or open windows Adjust zone, change installation site 4 FCC STATEMENT This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment. The device has been evaluated to meet general RF exposure requirement, the device can be used in portable exposure condition without restriction. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.