all | frequencies |
|
|
|
|
|
exhibits | applications |
---|---|---|---|---|---|---|---|---|
manual | photos | labels |
app s | submitted / available | |||||||
---|---|---|---|---|---|---|---|---|
1 |
|
0240-031-300 User manual Rev1 | Users Manual | 1.99 MiB | September 14 2022 / March 13 2023 | delayed release | ||
1 |
|
0240-031-300 Internal photo Rev1 | Internal Photos | 2.14 MiB | September 14 2022 / March 13 2023 | |||
1 |
|
0240-031-300 External photo r01 | External Photos | 949.44 KiB | September 14 2022 / March 13 2023 | |||
1 | ID Label/Location Info | September 13 2022 / September 14 2022 | ||||||
1 |
|
0240-031-300 Label&Location Rev1 | ID Label/Location Info | 91.37 KiB | September 14 2022 | |||
1 | 0240-031-300 BLOCK DIAGRAM | Block Diagram | September 14 2022 | confidential | ||||
1 | 0240-031-300 External photo | External Photos | September 13 2022 / March 13 2023 | delayed release | ||||
1 |
|
0240-031-300 FCC Agent Authorization Letter | Cover Letter(s) | 336.59 KiB | September 13 2022 / September 14 2022 | |||
1 |
|
0240-031-300 FCC Request for confidentiality letter | Cover Letter(s) | 802.98 KiB | September 14 2022 | |||
1 |
|
0240-031-300 Family models declaration letter | Attestation Statements | 187.03 KiB | September 14 2022 | |||
1 |
|
0240-031-300 Test setup photo | Test Setup Photos | 775.57 KiB | September 14 2022 / March 13 2023 | |||
1 |
|
4790346853-FE1V3 D & T INC | Test Report | 1.44 MiB | September 14 2022 |
1 | 0240-031-300 User manual Rev1 | Users Manual | 1.99 MiB | September 14 2022 / March 13 2023 | delayed release |
32 4K OLED Surgical Display 0240-031-300 Table of Contents Warnings and Cautions ..................................................................... EN-3 Warnings ..............................................................................................................EN-3 Cautions ...............................................................................................................EN-4 About Your Device ............................................................................. EN-6 Intended Use and Indications for Use .......................................................EN-6 Intended Conditions for Use ........................................................................EN-6 Contraindications .............................................................................................EN-6 Patient and/or User Population ...................................................................EN-6 Package Contents .............................................................................................EN-7 Device Features .................................................................................................EN-8 Setup ................................................................................................ EN-12 Connections .................................................................................................... EN-12 Basic Video Setup .......................................................................................... EN-16 Operation ......................................................................................... EN-17 On-Screen Display (OSD) ............................................................................ EN-17 OSD Menus ...................................................................................................... EN-19 Troubleshooting............................................................................................. EN-21 Cleaning and Maintenance ............................................................. EN-22 General Recommendations ....................................................................... EN-22 Cleaning ............................................................................................................ EN-22 Inspection ......................................................................................................... EN-23 Electrical Safety Testing ............................................................................... EN-23 Adverse Event Reporting ............................................................................ EN-23 Storage .............................................................................................................. EN-23 Service Life ....................................................................................................... EN-23 Disposal ............................................................................................................. EN-23 Technical Specifications .................................................................. EN-25 General Description ...................................................................................... EN-25 Classification and Approvals...................................................................... EN-26 Compliance ...................................................................................................... EN-26 Electromagnetic Compatibility ...................................................... EN-27 Symbols and Definitions ................................................................. EN-31 Device/Package Labeling ........................................................................... EN-31 Warnings and Cautions Please read this manual and follow its instructions carefully. The words warning, caution, and note carry special meanings and should be carefully reviewed:
Warning: Indicates measures to avoid potential serious injury to the user and the patient. Caution: Indicates risks to the equipment. Failure to follow cautions may result in product damage. Note: Provides special information to clarify instructions or present additional useful information. Warnings To avoid potential serious injury to the user and the patient, please note the following warnings:
1. 2. 3. 4. Read this manual thoroughly and be familiar with its contents prior to using this device. Federal law (United States of America) restricts this device to sale by, or on the order of, a physician. Carefully unpack the device and check if any damage occurred during shipment. This device is non-sterile and therefore should not be placed in the sterile field. 5. Do not place the device or any other heavy object on the power cord. Damage to the cord can cause fire or electric shock. 6. 7. 8. To avoid electric shock, avoid removing any components of the product housing. This device should not be used adjacent to or stacked with other devices. If adjacent or stacked use is necessary, the device should be observed to verify normal operation in the configuration in which it will be used. Test this device prior to a surgical procedure. This device was fully tested at the factory before shipment. 9. Do not attempt internal repairs or adjustments not specifically detailed in this manual. Ensure that readjustments, modifications, and/or repairs are carried out by persons authorized by Stryker Endoscopy. 10. Do not put any object into the panel. If this occurs, unplug the device and have it checked by qualified personnel before operating it any further. 11. Use appropriate caution to prevent contact with fluids if the device is being used with a power supply in patient environments. 12. The use of cables and/or other accessories with this device, other than those specified, may result in increased emissions or decreased immunity of this device. 13. This device has no means to be incorporated in an IT-network in the clinical environment. 14. The protective screen is made of tested impact resistant materials. Nonetheless there is the possibility that it may crack if subject to strong impacts. Evaluate and prevent the risk of possible breakages of the protective screen by correctly handling and positioning the display in the operating room. 15. To avoid risk of fire, do not use the device in the presence of flammable anesthetics. 16. To avoid risk of electric shock, this equipment must only be connected to a supply mains with protective earth. 17. Unplug the display power cord when it is going to be left unused for an extended period of time. 18. Unplug the display power cord from the AC outlet before any service. EN-3 19. If the display does not operate normally, for example, if there are any unusual sounds or smells emmitting from it, unplug it immediately and contact an authorized dealer or service center. Cautions 1. To achieve grounding reliability, connect the device to an AC adapter that is connected to a hospital-grade power cord, and ensure the power cord is plugged into a grounded power outlet. 2. Do not sterilize the device, as the delicate electronics cannot withstand this procedure. 3. 4. 5. 6. Use only the proprietary power supply for the display. If you use an extension cable, completely secure the connection to the DC power cord of the power supply. Never operate the device immediately after transportation from a cold location to a warm location. To connect to an international power supply, use an attachment plug appropriate for the power outlet, as outlined in the Technical Specifications section of this manual. Unplug the device if it is not to be used for an extended period of time. To disconnect the power cord from the display, unscrew the plug first, then pull the cord out by the plug. Never pull the cord itself. 7. Do not expose the device to moisture or apply liquid cleaners directly to the screen. Spray the cleaning solution onto a soft cloth and clean gently. For further detail, refer to the Cleaning and Maintenance section of this manual. 8. Allow adequate air circulation to prevent internal heat buildup. Do not place the device on surfaces (rugs, blankets, etc.) or near materials (curtains, draperies). The device is cooled by natural convection and has no fan. 9. Do not touch the patient with signal input or output connectors. Equipment with SIP/
SOP connectors should either comply with IEC 60601-1 and/or IEC 60601-1-1 harmonized national standards or the combination should be evaluated for safety. 10. To ensure electromagnetic compatibility, refer to the Electromagnetic Compatibility section of this manual. The 32 4K OLED Surgical Display (0240031300) must be installed and operated according to the EMC information provided in this manual. 11. Pay close attention to the cleaning instructions in this manual. A deviation may cause damage. 12. Do not install the device near sunlight, excessive dust, mechanical vibration, or shock. 13. Do not position the device so that it is difficult to disconnect the power cord from the supply mains. 14. Do not operate with the display screen facing downward. 15. Handle the device with care. Do not strike or scratch the screen. 16. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the device. 17. To connect the display over HDMI at lengths over 3 m, P47587 is recommended. Use of cables longer than 3m can lead to image instability. EN-4 Note: This device has been tested and found to comply with the limit for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This device generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation, which can be determined by turning the device off and on. The user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving device. Increase the separation distance between the device. Connect the device to an outlet on a circuit different from that to which the other device(s) are connected. Consult the manufacturer or field service technician for help. Note: Modifications not expressly approved by the party responsible for FCC compliance could void the users authority to operate the equipment. The warranty is void if any of these warnings or cautions are disregarded. This product contains electrical waste or electronic equipment. It must not be disposed of as unsorted municipal waste and must be collected separately. For more information, see Disposal. Note: Product fuse has a lower breaking capacity. Do not install at the building power system, prospective short-circuit current exceeding 35A. EN-5 About Your Device The 32 4K OLED Surgical Display is a wide screen OLED surgical display that can support a maximum resolution of 4K (4096 x 2160). The display supports the following video inputs: digital RGB (DVI) and HDMI 2.0b video inputs. It supports serial communication via the RS-232 port and SDC4K/HUB port. It also has USB ports that each supply power (5V, 1A) for accessories and peripherals (not used for data transfer). Intended Use and Indications for Use The 32 4K OLED Surgical Display is intended to display and transfer medical device data during general surgical procedures. The display is intended for use by qualified physicians and operating room personnel for general surgical procedures. Intended Conditions for Use This display is intended to be used in the near-patient environment. Contraindications There are no known contraindications for this device. Patient and/or User Population Adult and pediatric patients undergoing general surgical procedures. EN-6 Package Contents 1 2 5 4 3 Reference Part Number Package Contents 1 2 3 4 5 0240031300 32 4K OLED Surgical Display
Cable Cover
(4) M4 x 16 mm VESA screws 0240031004 Medical Power Supply Model: BPM150S24F11 (BridgePower)
Hospital-grade AC power cord Reference 0240031004 Optional Accessories Medical Power Supply Model: BPM150S24F11 (BridgePower) 0240030951 15 ft. (4.6 m) (5 pin) DC extension cable Model: 1501047***(BridgePower)***: blank or 001~999 0240030952 75 ft. (22.8 m) (5 pin) DC extension cable Model: 1501047***(BridgePower)***: blank or 001~999 P47587 AOC HDMI High Speed Cable, 10 m LG Model: MFG P47587 (Opticis USA, LLC) EN-7 Device Features Front Panel 1 1. 2. 3. 4. 5. 6. 7. 8. 9. PIP Bright Specialty Input Rotary control knob Logo light 10. Quick Keys light EN-8 10 2 3 9 4 5 6 7 8 Display screen Power switch (soft) Power LED Shows the video image Powers the display ON and OFF Indicates current status:
Solid Green - Display is powered on or is in screen saver mode Blinking Green - Display is in sleep mode Accesses the Picture in Picture adjustment menu. Accesses the Brightness adjustment menu. Accesses the Specialty selection menu. Accesses the Input selection menu. Accesses the on-screen menus and navigates through its function. Indicates current status:
No illumination - Off Continuous white illumination - On Slowly fading white illumination - Sleep mode (see Sleep Timer settings for detail) Indicates current status:
No illumination - Off Continuous white illumination - On Rear Panel 2 1 9 4 7 9 3 1 5 1 4 6 8 1. 2. 3. 4. 5. 6. 7. 8. 9. Accessory mount (3) VESA mounting holes Power switch (hard) Provide an access point for mounting optional accessories.
(accepts 1/4-20 screws) Provide access points for mounting the display using provided screws. (100x100mm, 200x100mm, accepts M4 x 16 mm screws) Turns the input DC power ON and OFF. Handles Aid in display positioning from the rear. Cable cover mounts Caution: The handles are not intended to bear the entire weight of the display. Attach the bottom of the cable cover to the display. Velcro straps Straps aid in cable management. Cable cover Covers and conceals cables. Cable cover screws Secure the cable cover onto the display. Accessory mount holes Provide access points for mounting optional video accessories. (accepts M4 x 16 mm screws) EN-9 Cable Cover Installing the Cable Cover 1. Align the left and right edges and screw holes of the cable cover onto the bottom rear of the display. 2. Rotate the two thumbscrews clockwise to secure the cable cover onto the display. Removing the Cable Cover 1. Rotate the two thumbscrews counter-clockwise until they have completely detached from the rear of the display. 2. Pull the cable cover away from the display to detach it from the display. EN-10 Display Handles Caution: The handles are intended to aid in positioning the display, not for transporting the display. The handles should not bear the full weight of the display. Removing the Display Handles 1. Using a Torx T10, loosen the two M3x14mm screws and gently pull the handle away from the display. Installing the Display Handles 1. 2. Align the handle with the screw holes on the rear of the display. Using a Torx T10, install the two M3x14mm screws to attach the handle. EN-11 Setup Stryker Endoscopy considers instructional training, or inservice, an integral part of this device. Your local Stryker Endoscopy sales representative will perform at least one inservice at your convenience to help set up your device and instruct you and your staff on its operation and maintenance. To schedule an inservice, contact your local Stryker Endoscopy representative after your device has arrived. Connections 1 2 3 4 5 6 7 8 Video input and output signals are connected to the rear of the display, as illustrated above:
1. Power Connector (24V) 2. DVI 3. 4. 5. 6. 7. 8. HDMI 4K (HDMI 2.0b) HDMI 4K (HDMI 2.0b) Service (for future updates) SDC4K/HUB device control port RS-232 communication port Accessory Power (5V/1A)x4 Connector Pin Assignments DC-Power Input Interface Connector Pin No. Assignment 1 2 3 4 5 Ground Ground
+24V (DC) Floating Ground
+24V (DC) EN-12 DVI Input Interface Connector Pin No. Assignment Pin No. Assignment 1 2 3 4 5 6 7 8 9 10 11 12 T.M.D.S. Data2-
T.M.D.S. Data2+
T.M.D.S. Data2 Shield No Connection No Connection DDC Clock DDC Data No Connection T.M.D.S. Data1-
T.M.D.S.Data1+
T.M.D.S. Data1 Shield No Connection 13 14 15 16 17 18 19 20 21 22 23 24 No Connection
+5V Power Ground Hot Plug Detect T.M.D.S. Data0-
T.M.D.S. Data0+
T.M.D.S. Data0 Shield No Connection No Connection T.M.D.S. Clock Shield T.M.D.S. Clock+
T.M.D.S. Clock-
HDMI Input Interface Connector Pin No. Assignment Pin No. Assignment 1 2 3 4 5 6 7 8 9 T.M.D.S. Data2+
T.M.D.S. Data2 Shield T.M.D.S. Data2-
T.M.D.S. Data1+
T.M.D.S. Data1 Shield T.M.D.S. Data1-
T.M.D.S. Data0+
T.M.D.S. Data0 Shield T.M.D.S. Data0-
11 12 13 14 15 16 17 18 19 T.M.D.S. Clock Shield T.M.D.S. Clock-
CEC Reserved SCL SDA Ground
+5V HPD 10 T.M.D.S. Clock+
EN-13 USB-B Type Input Interface Connector Pin No. Assignment 1 2 3 4 No Connection TXD (Monitor >
SDC4K/HUB) RXD (SDC4K/HUB
> Monitor) Ground RS-232 Input Interface Connector Pin No. Assignment 1 2 3 4 5 6 7 8 9 No Connection RXD (PC >
Monitor) TXD (Monitor >
PC) No Connection Ground No Connection No Connection No Connection No Connection EN-14 Connecting the Power Supply 1. 2. 3. 4. 5. Remove the cable cover. Connect the power supply to the 24V input on the display. Connect the AC power cord to the power supply*. Connect the AC power, using the supplied hospital-grade power cord.
(Optional, not shown) Connect a DC extension cord (15 ft./4.6 m Part Number 0240030951;
75 ft./22.8 m Part Number 0240030952) between the power supply and display. 6. Install cable cover.
* Power supply information: Model Number: BPM150S24F11, Manufacturer: BridgePower Corp. EN-15 Basic Video Setup The following video setup is intended as an example of how the display may be integrated with additional video components. 2 1 1. 2. Route the video output 1 from the camera to the (optional) Connected OR Hub HDMI input. Route the video output 1 from the (optional) Connected OR HUB HDMI output to the HDMI 4K input on the display. Note: The HDMI cable can be connected directly from camera to display if the HUB is not present. Note: Stryker recommends a backup connection directly from the camera to the display. EN-16 Operation Operate the display using the rotary control and the four buttons located on the front panel. A list of the display controls and their functions is provided below. On-Screen Display (OSD) Accessing the On-Screen Display 1 2 3 4 5 To use the four front-panel buttons:
1. 2. 3. 4. PIP: Press to activate Picture Mode (Picture in Picture, Picture by Picture) Bright: Press to activate the Brightness adjustment menu. Specialty: Press to activate the Specialty selection menu. Input: Press to activate the Input selection menu. Note: Press and hold any of the four front-panel buttons to exit the OSD menu. 5. Use the Rotary Control knob to navigate the on-screen menus once they are activated:
Push Accesses/selects on-screen display menu. Turn Right/Left With the on-screen display menu activated, turning increases/
decreases the value of the selected parameter. Push and Hold Exits on-screen display menu. EN-17 Operating On-Screen Display The device OSD helps navigate through various device menus. 1. 2. 3. 4. 5. Press the Rotary Control knob to activate the OSD menu. Rotate the Rotary Control knob to move up or down through the menu. The parameter is highlighted when selected. Press the Rotary Control knob to enter the next level OSD. Rotate the Rotary Control knob to increase or decrease the value of the selected parameter, or to make a selection on different options. To exit the OSD menu screen from the second or third level OSD menu, select the back arrow icon. To completely exit the OSD, press and hold the Rotary Control. If no keys are pressed, the OSD will automatically exit after the factory-set predetermined time (the time is customizable). EN-18 OSD Menus Specialty Menu Item Description Range Color Choose between color profiles. Color and gamma adjustment are available on each profile except PACS and Norm. STANDARD, ARTHRO A, ARTHRO B, LAP A, LAP B, ENV, ENT, PACS, NORM or GYN Red Green Blue Red balance Green balance Blue balance
-128 127
-128 127
-128 127 Gamma Gamma value 1.0 2.5, S0 - S8 Saturation Increase or decrease the color of saturation. 0 100 Color Space Adjustment of color gamut Native, BT.2020 Enhancement Color adjustment to enhance sharpness Off, Low, Med, High Brightness Settings Menu Item Description Brightness Increase or decrease the brightness. Contrast Increase or decrease the contrast. Image Sharpness Set image sharpness. Range 0 100 0 100 1 10 Image Effect Menu Item Description Scale Mode Choose scale mode between Fill All, Fill To Aspect, Fill All to Aspect, One To One, V-Fill or H-Fill. Freeze Frame Enable or disable the freeze frame. Mirror Enable or disable the mirror function. PIP PBP Enable PIP (picture in picture) function. Enable PBP (picture by picture) function. Rotate Set orientation of image. Range: Normal, 90, 180, and 270 Zoom Digitally zooms in on image. Range: 0 to 10 EN-19 Advanced Settings Menu Item Key Lock Description Key lock on: Disables all key functions (except Specialty and Inputs selection) Auto Source Select Scans inputs until an active video source is detected. Sleep After OSD Control Auto Source Select is disabled during PIP/PBP mode. 0 min: The display enters sleep mode if no active video source is detected. Never : The display will not enter sleep mode. Timer: Set the time until the display enters sleep mode: 30 or 60 minutes Controls OSD (On Screen Display) Menu Position, Background, and Timeout Restore Factory Settings Sets to factory default Com Port Selects which port to use for communications. SDC4K/HUB: Device control Select RS-232: SPI router control Converter power ON: Enables power to converter through HDMI port OFF: Disables power to converter through HDMI port Timing Table Enable: Default signal detection and display output Disable: Recommended for detecting signal in iSuite setups Information Menu Item Description Display Name Entry Enter custom name to be displayed in screen saver mode Serial Number Display device serial number Runtime Input Resolution Color Format Display device total run time Display current input format Display detected input resolution Display current color format (RGB or YCbCr) Note: Actual on-screen display values may vary with updated version of the firmware and user settings. EN-20 Troubleshooting Before returning your display for service, consult the troubleshooting list below:
Problem No picture Current Status Remedy Power LED on Power LED off Power LED blinking Using the OSD Menu, increase the brightness and contrast or reset them to their default settings. Check the power supply functionality. Ensure the power switch at the rear of the display is set to ON. Check if the AC power cord is properly connected to the AC adapter and outlet. Check that the power supply is fully connected and functioning properly. Display is in sleep mode. Connect active sources or press the rotary control knob or any quick key to wake the display. Converters not powering on Check that the converter power setting is ON in the OSD menu. Abnormal picture Oversized, undersized or missing video Turn the hard power switch off and on again. Adjust Scale Mode or Zoom settings. Wait a few seconds after initial sync of video signals, or turn the hard power switch off and on again. OSD Error message Resolution not supported Set the Timing Table in the OSD menu to Disable. Turn the hard power switch off and on again. EN-21 Cleaning and Maintenance Warning Caution To avoid electric shock and potentially fatal injury, unplug the display and power supply from the electrical outlet before cleaning. Do not spray cleaning liquid directly onto the display or the power supply as product damage may result. Spray on the cloth before wiping the unit. Do not immerse the display or power supply in any liquid as product damage will result. Do not use corrosive cleaning solutions to clean the display or power supply as product damage may result. Do not sterilize the display or power supply as product damage may result. General Recommendations Keep the display clean to prolong its operational lifetime OLED panel performance may deteriorate over time. Ensure that the image output is acceptable. Periodically check the tightness of the VESA mount screws. If not sufficiently tight, the display may detach from the arm, which may result in injury or equipment damage. Cleaning Note: Take extra care when cleaning the display screen. Excess liquid that enters the display housing, connectors, or controls may result in product damage. Note: User shall decontaminate (e.g. clean, disinfect as appropriate) all potentially contaminated devices prior to returning them Stryker. To clean the display 1. 2. Clean and disinfect the display using a germicidal disposable wipe (or equivalent combination of germicidal spray and sterile cloth) according to the manufacturers instructions.1 Visually inspect the external surface of the display for cleanliness, focusing on hard-to-reach areas. If visible soil remains, repeat cleaning and disinfection until all visible soil is removed. 1 Cleaning and disinfection were validated using PDI Super Sani-Cloth Germicidal Disposable Wipes. Preventive Maintenance With the display disconnected from mains perform the following periodical check:
Check the integrity of the power cord and inspect its routing, so that it is not under the risk of being punched or cut. Clean the area around the power plug, dust and liquids may result in fire. Clean the ventilation slot of the display, dust can obstruct the air flow and cause temperature increase of the electronics. EN-22 Inspection Inspect the device on a continual basis for unacceptable deterioration such as (but not limited to) corrosion, discoloration, pitting, cracked seals, or abnormal noises. If a problem is observed or suspected, the device should be returned for service. Electrical Safety Testing Testing of ground protective earthing from the display is not necessary. Protective earthing is assured by the certified external power supply. Adverse Event Reporting Any serious incident that has occurred in relation to this device should be reported to Stryker and, in the European Union, to the competent authority of the Member State in which the affected person resides. Storage Never store the device in a non-ventilated, humid environment. This can damage the delicate electronics in the device. Service Life The devices service life is largely determined by wear, processing methods, and any damage resulting from use. To extend the time between device servicing, always follow the care and handling instructions in this user manual. Before each use, test the device functionality and inspect it for any sign of damage per the Inspection section. If the device does not properly function or appears to be damaged, return it to Stryker for evaluation and possible repair or replacement. Repairs through Stryker as the equipment manufacturer bring the device back to manufacturer specifications. Clean and (when applicable) sterilize all potentially contaminated devices before returning them to Stryker. Disposal In accordance with European Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE) as amended, product should be collected separately for recycling. Do not dispose of as unsorted municipal waste. Contact local distributor for disposal information. Ensure infected equipment is decontaminated prior to recycling. EN-23 Product Recycling Information 32 4K OLED Surgical Display 0240031300 7 6 5 4 15 16 14 13 12 11 10 18 17 3 2 1 8 9 Item Description Qty Type Item Description Qty Type 1 2 3 4 5 6 7 8 9 POWER SWITCH POWER SW TO LOGO LIGHT HARNESS PANEL ASSY T-CON TO DMB100 MAIN eDP PANEL T-CON FFC 40 P-R DCM100 DMB100 TO DCM100 HARNESS DMB TO LOGO LIGHT FFC LOGO LIGHT 1 1 1 1 1 1 1 1 1 Circuit Board Circuit Board 10 11 ROTARY SW QUICK KEY Circuit Board 12 Circuit Board 13 Cable Circuit Board Circuit Board Circuit Board Circuit Board 14 15 16 17 18 QUICK KEY TO ROTARY SW HARNESS LOGO LIGHT TO QUICK KEY HARNESS PANEL T-CON FFC 100P PANEL T-CON FFC 40P-L SL150M TO GND 7 DMB100 HARNESS DMB100 MAIN MAIN TO PANEL LED DRIVER CABLE 1 1 1 1 1 1 1 1 1 Circuit Board Circuit Board Circuit Board Circuit Board Cable Cable Circuit Board Circuit Board Circuit Board EN-24 Technical Specifications General Description Item Description OLED Panel Description 31.5 (800.1mm) diagonal Native Resolution 3840 (H) dots x 2160 (V) lines Display colors 10-bit Pixel Pitch 0.1818 mm x 0.1818 mm Response time
(typical) 0.1 ms Black to White Viewing Angle Horizontal/Vertical: 178 Brightness 540 nits (peak), 250 nits (raster) Contrast 1,000,000:1 Input Output 1 x DVI 2 x HDMI 4K (HDMI 2.0b) 1 x RS-232 (SPI router control) 1 x SDC4K/HUB device control interface (USB-B) 4 x USB-A (5V, 1A power only; not used for data transfer) Brightness and Contrast Input/
Output Temperature Operating 50 to 104 F (10 to 40 C) Transport and Storage 0 to 140 F (-18 to 60 C) Relative Humidity Operating 15 to 75%
Transport and Storage 15 to 90%
Electrical Power Adapter Input: 100 240 VAC; 50 60 Hz; 2.5 A Output: 24V DC; 6.25A (150W Max) Model Number: BPM150S24F11 Power Consumption 20 115.2 Watts Marked Rating: 24V DC; 4.8A Up to 3000 m Altitude Impact Resistance Ingress Protection (Dust and Liquid) IK06 (Front): Protected against 1 joule of impact. The equivalent to the impact of a 0.5 kg mass dropped from 20 cm above the impacted surface. IP55 (Front): Protected against quantity of dust that could interfere with the normal operation of the product but is not fully dust tight. The product is completely protected against solid objects. It is also protected against water jets projected by a nozzle (6.3 mm) from any angle. IP43 (Rear): Protected from tools and small wires greater than 1mm, protection from ingress of spraying water (less than 60 from vertical). EN-25 Item Description Current/
Voltage Rating 110V 10V power outlets Select a power supply cord that is UL Listed and C.S.A Certified, type SJT or SVT, 3 conductor, 18AWG, terminated in a molded on hospital grade plug cap rated 110V 10 V, 15A, with a minimum length of six feet. 220V 20V power outlets Select a power supply cord that is internationally harmonized and marked
<HAR>, 3 conductor, 0.75mm^2 minimum wire, rated 220V 20V, 10A with a PVC insulated jacket. The cord must have a molded on plug cap rated 220V 20V, 10A. The cord and plug cap must be suitable for medical use. Display Weight with Cable Cover
(approximate) Display Weight without Cable Cover
(approximate) Power Supply Weight 15.6 lbs 15.3 lbs 1.75 lbs Unit Dimensions (W x H x D) 28.7 x 18.3 x 2.1in (729.7 x 465 x 53.2mm) VESA Mounting Interface Dimensions VESA 100 x 100mm VESA 100 x 200mm Accessory Mounting Interface Dimensions
(x2) M4x16mm (118.4mm vertically spaced)
(x4) M4x 16mm (75x75mm VESA pattern)
(x1) 1/4-20 Nut (top)
(x2) 1/4-20 Nut (Bottom) Classification and Approvals Class 1 Equipment Medical equipment with respect to electric shock, fire, and mechanical hazards only in accordance with ANSI/AAMI ES60601-1 and CAN/CSA C22.2 No. 60601.1. IP43: Protected from tools and small wires greater than 1mm, protection from ingress of spraying water (less than 60 from vertical) Continuous Operation Compliance FCC Regulations: FCC Part 15 Class B FCC Identifier: THCDTMM3150A Canadian Notice: CAN ICES-3 (B)/NMB-3(B) CE medical device class I Note: Please contact your local Stryker Endoscopy sales representative for information on changes and new products. EN-26 Electromagnetic Compatibility Like other electrical medical equipment, the 32 4K OLED Surgical Display requires special precautions to ensure electromagnetic compatibility (EMC) with other electrical medical devices. To ensure electromagnetic compatibility, the display must be installed and operated according to the EMC information provided in this manual. The display has been designed and tested to comply with IEC 60601-1-2 requirements for EMC with other devices. Warning When this device is connected with other electrical equipment, leakage currents may be additive. To minimize total leakage current per patient, ensure that all systems are installed according to the requirements of IEC 60601-1. Caution Portable and mobile RF communications equipment may affect the normal function of the display. Do not use cables or accessories other than those provided with the display, as this may result in increased electromagnetic emissions or decreased immunity to such emissions. If the display is used adjacent to or stacked with other equipment, observe and verify normal operation of the display in the configuration in which it will be used prior to using it in a surgical procedure. Consult the tables below for guidance in placing the display. Guidance and Manufacturers Declaration: Electromagnetic Emissions The 32 4K OLED Surgical Display is intended for use in the electromagnetic environment specified below. The customer or the user of the display should ensure it is used in such an environment. Emissions test Compliance Electromagnetic environment - guidance RF emissions CISPR 11 Group 1 RF emissions CISPR 11 Class B Harmonic emissions IEC 61000-3-2 Class A Voltage Fluctuations/ flicker emissions IEC 61000-3-3 Complies The display use RF energy only for their internal function;
therefore, their RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. The display is suitable for use in all establishments other than domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes, provided the following warning is heeded:
Warning: This system is intended for use by health care professionals only. This system may cause radio interference or may disrupt the operation of nearby equipment. It may be necessary to take mitigation measures, such as reorienting or relocating the system or shielding the location. EN-27 Guidance and Manufacturers Declaration: Electromagnetic Immunity The 32 4K OLED Surgical Display is intended for use in the electromagnetic environment specified below. The customer or the user of the display should ensure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electrostatic Discharge (ESD) IEC61000-4-2 8kV contact 8kV contact 15kV air 15kV air Electromagnetic Environment Guidance Floors should be wood, concrete, or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %. Electrical fast transient/burst 2kV (input a.c. power port) 2kV (input a.c. power port) 1kV (signal ports) IEC61000-4-4 1kV (signal ports) Mains power quality should be that of a typical commercial or hospital environment. Surge IEC61000-4-5
( 0.5, 1, 2)kV; line to earth
( 0.5, 1)kV; line to line
( 0.5, 1, 2)kV; line to earth
( 0.5, 1)kV; line to line Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment. If the user of the transmitter requires continued operation during power mains interruptions, it is recommended that the Wireless Transmitter be powered from an uninterruptible power supply or a battery. Voltage dips and interruptions 0% UT 0.5 cycle 0% UT 0.5 cycle 0% UT 1 cycle 0% UT 1 cycle 70% UT 25 cycles 70% UT 25 cycles 0% UT 5 Sec 0% UT 5 Sec IEC61000-4-11 Supplementary information:
If the Rated voltage range
<25% of the lowest rated input voltage, one rated input voltage. Otherwise, minimum and maximum rated voltage. EUT powered at one of the Nominal input frequencies. ME EQUIPMENT and ME SYSTEMS with power input voltage selection by transformer taps shall be tested at only one tap setting. Supplementary information:
If the Rated voltage range <25% of the lowest rated input voltage, one rated input voltage. Otherwise, minimum and maximum rated voltage. EUT powered at one of the Nominal input frequencies. ME EQUIPMENT and ME SYSTEMS with power input voltage selection by transformer taps shall be tested at only one tap setting. 30 A/m 30 A/m Power-frequency magnetic fields should be at levels characteristic of a typical location in a typical commer-
cial or hospital environment. Power frequency
(50/60Hz) magnetic field IEC 61000-4-8 Note: UT is the AC mains voltage prior to application of the test level. EN-28 Guidance and Manufacturers Declaration: Electromagnetic Immunity The 32 4K OLED Surgical Display is intended for use in the electromagnetic environment specified below. The customer or the user of the display should ensure that it is used in such an environment. Immunity Test IEC 60601 Test level Compliance Level Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 3 Vrms 10 V/m 3 Vrms 10 V/m 80MHz to 2.7 GHz 80MHz to 2.7 GHz Electromagnetic Environment -
Guidance Portable and mobile RF communications equipment should be used no closer to any part of the display, including their cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended Separation Distance:
d = 2vP 80 MHz to 2.7 GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey (a), should be less than the compliance level in each frequency range(b). Interference may occur in the vicinity of equipment marked with the following symbol:
(a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast, cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the 32 4K OLED Surgical Display is used exceeds the applicable RF compliance level above, the display and transmitter should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the display.
(b) Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. EN-29 Guidance and Manufacturers Declaration: Electromagnetic Immunity Test frequency
(MHz) Band
(MHz) Service Modulation Maximum power
(W) Immunity test level (V/m) 380-390 TETRA 400 430-470 GMRS 460, FRS 460 704 - 787 LTE Band 13, 17 Pulse modulation 18 Hz FM 5 kHz deviation 1 kHz sine Pulse modulation 217 Hz 1.8 2 0.2 800-960 1700-1990 2400-2570 GSM 800/900, TETRA 800, iDEN 820, CDMA 850, LTE Band 5 GSM 1800; CDMA 1900; GSM 1900;
DECT;
LTE Band 1, 3, 4, 25; UMTS Bluetooth, WLAN, 802.11 b/g/n, RFID 2450, LTE Band 7 Pulse modulation 18 Hz Pulse modulation 217 Hz Pulse modulation 217 Hz 2 2 2 5100-5800 WLAN 802.11 a/n Pulse modulation 217 Hz 0.2 27 28 9 28 28 28 9 385 450 710 745 780 810 870 930 1720 1845 1970 2450 5240 5500 5785 Note: Portable RF Communication equipment should be used no closer than 30cm to 32 4K OLED Surgical Display. Otherwise, degradation of the performance of this equipment could result. EN-30 Symbols and Definitions The following symbols appear on the product, its labeling, or the product packaging. Each symbol carries a special definition, as defined below:
Device/Package Labeling Consult instructions for use Federal law (USA) restricts this device to use by, or on order of, a physician Date of manufacture Legal manufacturer Product catalog number Product serial number Quantity Country of Origin The device meets European Union medical device requirements. Medical device in the European Union Authorized representative in the European Community Unique Device Identification Do Not Get Device Wet Maximum Stacking Fragile This Side Up No Serviceable Parts Direct Current EN-31 DC Power Control Switch For Indoor Use Only Efficiency Level Japan PSE Mark Denan UI, Functional Safety Recognized Component China Compulsory Certificate Mark Enclosure provides protection against:
Protected from tools and small wires greater than 1mm Spraying water (less than 60 from vertical) Medical Equipment is in accordance with ANSI/AAMI ES60601-1 (2005) + AMD 1 (2012) and CAN/CSA-C22.2 No. 60601-1 (2014) in regards to electric shock, fire hazards, and mechanical hazards. Device recycling code (applicable in China) This product contains electrical waste or electronic equipment. It must not be disposed of as unsorted municipal waste and must be collected separately. User Manual Caution (consult instructions for use) Radiation emitting EN-32 Produced for:
Stryker Endoscopy 5900 Optical Court San Jose, CA 95138 USA 1-800-624-4422 U.S. Patents: www.stryker.com/patents Stryker European Operations Limited Anngrove, IDA Business & Technology Park Carrigtwohill, Co Cork T45 HX08 lreland Stryker or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: the Stryker logo. All other trademarks are trademarks of their respective owners or holders. P51406 A 2022/08
1 | 0240-031-300 Internal photo Rev1 | Internal Photos | 2.14 MiB | September 14 2022 / March 13 2023 |
1 | 0240-031-300 External photo r01 | External Photos | 949.44 KiB | September 14 2022 / March 13 2023 |
1 | 0240-031-300 Label&Location Rev1 | ID Label/Location Info | 91.37 KiB | September 14 2022 |
FCC ID :
THCDTMM3150A Page : 1 of 1 Label/Location Label Location UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea TEL: (031) 337-9902 FAX: (031) 213-5433
1 | 0240-031-300 FCC Agent Authorization Letter | Cover Letter(s) | 336.59 KiB | September 13 2022 / September 14 2022 |
Date: May 26, 2022 UL Korea, Ltd. Suwon Laboratory 218 Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16675, Korea To whom it may concern:
I, the undersigned, hereby authorize UL Korea, Ltd. Suwon Laboratory, to act on our behalf in all manners relating to application for equipment authorization, including signing of all documents relating to these matters. Any and all acts carried out by UL Korea, Ltd. Suwon Laboratory on our behalf shall have the same effect as acts of our own. In authorizing UL Korea as our agent, we still recognize that we are responsible to:
a) comply with the relevant provisions of the certification program;
b) make all necessary arrangements for the conduct of the evaluation, including provision for examining documentation and access to all areas, records (including internal audit reports) and personnel for the purposes of evaluation (e.g. testing, inspection, assessment, surveillance, reassessment) and resolution of complaints;
c) make claims regarding certification only in respect of the scope for which certification has been granted;
d) do not use our product certification in such a manner as to bring the Certification Division into disrepute and not make any statement regarding our product certification which the Certification Division may consider misleading or unauthorized;
e) upon suspension or cancellation of certification, discontinue use of all advertising matter that contains any reference thereto and return any certification documents as required by the Certification Division;
f) use certification only to indicate the products are certified as being in conformity with specified standards;
g) endeavor to ensure that no certificate or report nor any part thereof is used in a misleading manner;
h) ensure that any reference to our product certification in communication media such as documents, brochures or advertising, complies with the requirements of the Certification Division;
i) keep a record of all complaints made known to the us relating to the products compliance with requirements of the relevant standard and to make these records available to the when requested;
j) take appropriate action with respect to such complaints and any deficiencies found in products or services that affect compliance with the requirements for certification;
k) document the actions taken. l) the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). This authorization is valid until further written notice from the applicant. Sincerely Yours, Park Kyutae / Manager D&T Inc. TEL: +82-42-360-0820 E-mail: wwlee88@dntinc.co.kr
1 | 0240-031-300 FCC Request for confidentiality letter | Cover Letter(s) | 802.98 KiB | September 14 2022 |
May 26, 2022 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject:
Request for Confidentiality FCC ID:
THCDTMM3150A To Whom It May Concern:
Pursuant to the provisions of Sections 0.457 and 0.459 of the Commissions rules (47 CFR 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Block Diagram Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commissions policy, in order to comply with the marketing regulations in 47 CFR 2.803 and the importation rules in 47 CFR 2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments until 180 days. External Photos Internal Photos Test Setup Photos User manual It is our understanding that all measurement test reports, FCC ID label format and correspondence during certification review process cannot be granted as confidential documents and such information will be available for public review once the grant of equipment authorization is issued. Best Regards Park Kyutae / Principal Research Engineer D&T Inc. TEL: +82-42-360-0820 E-mail: wwlee88@dntinc.co.kr
1 | 0240-031-300 Family models declaration letter | Attestation Statements | 187.03 KiB | September 14 2022 |
Family models declaration letter Date: 2022-05-26 FCC ID: THCDTMM3150A Product name: 32 4K OLED Surgical Display Model name: 0240-031-300 Family model name: 240031300, 0240031300, 0-240-031-300, 240.031.300, 0240.031.300, 0.240.031.300, DTM-M3150A To Whom It May Concern:
We, D&T Inc., declares 32 4K OLED Surgical Display has these models: 0240-031-
300, 240031300, 0240031300, 0-240-031-300, 240.031.300, 0240.031.300, 0.240.031.300, DTM-M3150A. All models are all identical in interior structure, electrical circuits and components, and just model names are different for the marketing requirement. Thanks. Sincerely, Park Kyutae / Principal Research Engineer D&T Inc. TEL: +82-42-360-0820 E-mail: wwlee88@dntinc.co.kr
1 | 0240-031-300 Test setup photo | Test Setup Photos | 775.57 KiB | September 14 2022 / March 13 2023 |
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2022-09-14 | JBP - Part 15 Class B Computing Device Peripheral | Original Equipment |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 | Effective |
2022-09-14
|
||||
1 | Applicant's complete, legal business name |
D&T Inc.
|
||||
1 | FCC Registration Number (FRN) |
0013754916
|
||||
1 | Physical Address |
26-121, Gajeongbuk-ro, Yuseong-gu
|
||||
1 |
Daejeon, N/A
|
|||||
1 |
South Korea
|
|||||
app s | TCB Information | |||||
1 | TCB Application Email Address |
L******@ul.com
|
||||
1 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 | Grantee Code |
THC
|
||||
1 | Equipment Product Code |
DTMM3150A
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 | Name |
P******** K********
|
||||
1 | Title |
Principal Research Engineer
|
||||
1 | Telephone Number |
+82-4********
|
||||
1 | Fax Number |
+82-4********
|
||||
1 |
k******@dntinc.co.kr
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 | If so, specify the short-term confidentiality release date (MM/DD/YYYY format) | 03/13/2023 | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 | Equipment Class | JBP - Part 15 Class B Computing Device Peripheral | ||||
1 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | 32inch 4K OLED Surgical Display | ||||
1 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 | Modular Equipment Type | Does not apply | ||||
1 | Purpose / Application is for | Original Equipment | ||||
1 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | No | ||||
1 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 | Firm Name |
UL Korea, Ltd.
|
||||
1 | Name |
J****** L****
|
||||
1 | Telephone Number |
82313********
|
||||
1 | Fax Number |
+82-3********
|
||||
1 |
J******@ul.com
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15B | 28 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC