Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) Adjustable Bed Controller (ABC-2 Series) Users Manual
-1-
Elisync Technologies LLC. Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) LABELLING REQUIREMENTS (FCC Part 15.19 (a)(3)) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. INFORMATION TO THE USER (Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help. WARNING (Part 15.21) The manufacturer is not responsible for any Radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the users authority to operate the equipment. Elisync Technologies LLC.
-2-
Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) DOCUMENT HISTORY REVISION 1.0 1.1 1.2 DATE 2005.07.08 2005.07.12 2005.08.23 COMMENTS 1ST revision created UP/DOWN reversed FCC Information is added. Elisync Technologies LLC.
-3-
Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) CONTENTS DOCUMENT HISTORY...................................................................................... 3 CONTENTS........................................................................................................ 4 1. Introduction .................................................................................................. 5 1.1 Features................................................................................................. 5 1.2 Systems Configuration......................................................................... 6 2. Hand Control................................................................................................. 7 2.1 Specification.......................................................................................... 7 2.2 Photo...................................................................................................... 7 2.3 Dimension.............................................................................................. 8 3. Control Box................................................................................................... 9 3.1 Specification.......................................................................................... 9 3.2 Photos.................................................................................................... 9 3.3 Dimension............................................................................................ 10 4. Control Box - Details.................................................................................. 11 4.1 Front View Layout............................................................................... 11 4.2 Rear View Layout ................................................................................ 11 4.3 ACTUATOR Connectors ..................................................................... 11 4.4 MASSAGE MOTOR Connectors......................................................... 12 4.5 AC INPUT Connector .......................................................................... 12 4.6 Safety SWITCH (Optional) .................................................................. 12 4.7 STATUS LED........................................................................................ 13 4.8 PAIRING Button................................................................................... 13 4.9 PCB Layout (Fuse, Header)................................................................ 13 5. System Setup Method................................................................................ 14 5.1 Wireless PAIRING Setup..................................................................... 14 6. Hand Control Operation............................................................................. 15 6.1 Bed Position ........................................................................................ 15 6.2 Bed Position Save & Recall................................................................ 16 6.3 Massage Mode .................................................................................... 17 Elisync Technologies LLC.
-4-
Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 1. Introduction 1.1 Features ABC-2 series adjustable bed controller is for adjust the bed to fit any position you like. With wireless hand control, you can raise your head and/or your feet to a position that most comfortable to you. It controls the vibration motors for massage as well as the head and foot actuators. Various massage operation such as single massage, dual massage, and wave massage can be achieved with wireless hand control. Elisync Technologies LLC.
-5-
Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 1.2 Systems Configuration Hand Control ABC-200HC-010 Max. 10M (30ft) AC120V PAIRING STATUS AC INPUT Adjustable Bed Controller Control Box ABC-200CB-010 HEAD Actuator FOOT Actuator BACK Massager LEG Massager Elisync Technologies LLC.
-6-
Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 2. Hand Control 2.1 Specification Item Model Massage Function Specification ABC-200HC-010 Massage Mode: Manual / Wave Massage Intensity: 5 steps Timer: 30min 315MHz (FCC Part C 15.231) Max. 10 meters (30 feet) DC 3V, 2 AAA Alkaline Batteries 182.7mm(H) x 64.7mm(W) x 22.0mm(D) 255g Temperature: -10~60 Humidity: 85% RH
* Model for 3 actuators(Head/Foot/Bed) version: ABC-200HC-020 Radio Frequency Radio Transmission Range Power Supply Dimension Weight Operating Condition 2.2 Photo Elisync Technologies LLC.
-7-
2.3 Dimension m m 7
. 2 8 1 Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 64.7mm 22.0mm Elisync Technologies LLC.
-8-
Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 3. Control Box 3.1 Specification Item Model No. of Control Output Massage Function Radio Frequency AC Power Input Dimension Weight Operating Condition Specification ABC-200CB-010 2 Actuators: Head, Foot 2 Massage Motors: Back, Leg Massage Mode: Manual / Wave Massage Intensity: 5 steps Timer: 30min 315MHz (FCC Part C 15.231) AC120V, 1Phase, 60Hz 215mm(W) x 140mm(D) x 40mm(H) 460g Temperature: -10~60 Humidity: 85% RH
* Model for 3 actuators(Head/Foot/Bed) version: ABC-200CB-020 3.2 Photos
[Front View]
[Rear View]
Elisync Technologies LLC.
-9-
3.3 Dimension Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) Elisync Technologies LLC.
-10-
Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 4. Control Box - Details 4.1 Front View Layout 4.2 Rear View Layout 4.3 ACTUATOR Connectors
PCB Header
- MOLEX 5569-4pins, Right Angle/Dual Row
Cable Receptacle
- MOLEX 5557-4pins, Dual Row
PIN Assignment
- Pin 1: UP
- Pin 2: GND
- Pin 3: NEUTRAL
- Pin 4: DOWN Elisync Technologies LLC.
-11-
Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 4.4 MASSAGE MOTOR Connectors
PCB Header
- MOLEX 5569-4pins, Right Angle/Dual Row
Cable Receptacle
- MOLEX 5557-4pins, Dual Row
PIN Assignment
- Pin 1: MASSAGER
- Pin 2: GND
- Pin 3: NEUTRAL
- Pin 4: N/C 4.5 AC INPUT Connector
PCB Header
- Hanlim LAB1143-03, Right Angle
Cable Receptacle
- Hanlim CHB1143-03
PIN Assignment
- Pin 1: NEUTRAL
- Pin 2: GND
- Pin 3: HOT(LINE) 4.6 Safety SWITCH (Optional)
PCB Header
- MOLEX 5569-2pins, Right Angle/Single Row
Cable Receptacle
- MOLEX 5557-2pins, Single Row
PIN Assignment
- Pin 1: N/C
- Pin 2: DC5V
- Pin 3: Hand Control
- Pin 4: N/C Ignoring Safety Switch
- Safety switch is ignored by inserting jumper into JP1 header on PCB.
Elisync Technologies LLC.
-12-
Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 4.7 STATUS LED
GREEN LED
- Power Status, Wireless Pairing Status 4.8 PAIRING Button
For pairing between Hand Control and Control Box. 4.9 PCB Layout (Fuse, Header) Safety SWITCH Header
- Jumper ON: Switch disabled
- Jumper OFF: Switch enabled Fuse: AC250V, 10A Elisync Technologies LLC.
-13-
Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 5. System Setup Method 5.1 Wireless PAIRING Setup 1) In control box, press and release the PAIRING button to go into pairing mode. The GREEN INDICATOR light will begin to flash in 0.2 second interval. The pairing mode continues 10 seconds. After 10 seconds, control box exits from pairing mode automatically. 2) In hand control, press and hold the SET button for 3 seconds to go into pairing mode. The GREEN INDICATOR light will begin to flash in 1 second interval. control continuously transmits its unique ID. The pairing mode continues 10 seconds. After 10 seconds, hand control exits from pairing mode automatically. Pressing the SET button also stops the GREEN INDICATOR flashing. pairing mode, hand 3) Control box tries to find available ID transmitted from hand control. The pairing process will go on until control box finds any available ID. If it finds the ID, pairing will be completed and the GREEN INDICATOR light turns on again. In
Electronic ID Each hand control has unique, factory-lasered 16-bit registration ID number that provides an absolutely unique identity, which guaranteed no two hand control alike.
RECOVERY FROM PAIRING FAIL Due to electrical writing timing problem, the PAIRING information saved on EEPROM of CPU may be erased in some cases. If it happens, please retry of PAIRING process again. Elisync Technologies LLC.
-14-
Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 6. Hand Control Operation 6.1 Bed Position
HEAD UP/DOWN Button
To raise the head of the bed, press and hold the HEAD-
UP button. Release the button when you achieve the desired bed position.
To lower the head of the bed, press and hold the HEAD-DOWN button. Release the button when you achieve the desired bed position.
FOOT UP/DOWN Button
To raise the foot of the bed, press and hold the FOOT-
UP button. Release the button when you achieve the desired bed position.
To lower the foot of the bed, press and hold the FOOT-
DOWN button. Release the button when you achieve the desired bed position.
AUTO UP/DOWN Button
To make the bed its maximum position, press the AUTO-UP button. The head and foot position of the bed move automatically until the bed become maximum position.
To make the bed flat, press the AUTO-DOWN button. the bed move The head and foot position of automatically until the bed become flat. If any button on the hand control excluding AUTO-UP or AUTO-DOWN button is momentarily pressed while the bed is moving, the bed is stop and the pressed buttons function is not engaged.
Elisync Technologies LLC.
-15-
Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 6.2 Bed Position Save & Recall
POS1 & POS2 Button (Position Recall)
Press the POS1 button to recall the programmed bed position 1. The bed moves automatically until the head and foot position reached to the programmed Position 1 saved.
Press the POS2 button to recall the programmed bed position 2. The bed moves automatically until the head and foot position reached to the programmed Position 2 saved. If any button on the hand control excluding POS1 or POS2 button is momentarily pressed while the bed is moving, the bed is stop and the pressed buttons function is not engaged.
SET Button (Position Memory)
To save the current bed position as Position 1, press SET and POS1 button in sequence. The current bed position is saved as Position 1.
To save the current bed position as Position 2, press SET and POS2 button in sequence. The current bed position is saved as Position 2.
Position data in Memory Bed position data is saved in RAM of control box and is kept until the power is supplied. When the power of control box is turned of, position data are cleared to zero. Elisync Technologies LLC.
-16-
Users Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 6.3 Massage Mode
WAVE Button
Press the WAVE button to activate the Wave Program 1 with 30 minutes timer.
Press the WAVE button 2nd time to activate the Wave Program 2.
Press the WAVE button to toggle between Program 1 and Program 2 repeatedly.
Press the WAVE button for 2 seconds to stop both massage motors. At the end of 30 minutes, both massage motors are automatically turned off.
Back Massage Buttons
Press the UP or DOWN button to activate back massage motor with 30 minutes timer.
The back massage motor starts with intensity level 5 for 1 second and then drops to last intensity level used.
Whenever UP button is pressed, the back massage intensity level is increased to 1 level higher. Whenever DOWN button is pressed, the back massage intensity level is decreased to 1 level lower. If the UP or DOWN button is pressed for 2 seconds, back massage motor stops. At the end of 30 minutes, back massage motor is automatically turned off.
Leg Massage Buttons
Press the UP or DOWN button to activate leg massage motor with 30 minutes timer.
The leg massage motor starts with intensity level 5 for 1 second and then drops to last intensity level used.
Whenever UP button is pressed, the leg massage intensity level is increased to 1 level higher. Whenever DOWN button is pressed, the leg massage intensity level is decreased to 1 level lower. If the UP or DOWN button is pressed for 2 seconds, leg massage motor stops. At the end of 30 minutes, leg massage motor is automatically turned off.
Wave Program 1 Both massage motors start and change intensity simultaneously. Back massage starts on speed 1,2,3,4,3,2, repeatedly. Leg massage starts 4,3,2,1,2,3.
Wave Program 2 Both massage motors start and change intensity simultaneously. Back massage starts on speed 2,4,2,4 repeatedly. Leg massage starts 4,2,4,2 repeatedly. Elisync Technologies LLC.
-17-