User Manual Danfoss Wireless Control Panel OPXxx
(DRAFT) Danfoss A/S Ulsnaes 1 DK-6300 Graasten vlt-drives.danfoss.com Classified as Business TABLE OF CONTENTS:
1. 2. The wireless Control Panel Installation Instructions 2.1 Safety and Installation Awareness ................................................................ 5 2.2 Verifying Shipment and Contents .................................................................. 5 2.2.1 Items Supplied ........................................................................................ 5 2.2.2 Control Panel Compatibility ..................................................................... 6 2.3 Installing the Control Panel ........................................................................... 6 2.4 Status Indicators ........................................................................................... 7 Installation instruction for best radio reception ............................................... 8 2.5 2.5.1 Wireless CP installed in a drive ............................................................... 8 2.5.2 Wireless CP installed remotely in a cradle .............................................. 9 Installation Illustrations ................................................................................ 10 Illustrations ........................................................................................... 10 2.6.1 2.6 3. Connection Procedure 3.1 Access Point Mode ..................................................................................... 11 3.2 Client mode ................................................................................................. 11 3.3 LED pattern ................................................................................................. 12 3.3.1 Status indicators ................................................................................... 12 3.3.2 Wireless indicators Access Point Mode ............................................. 12 3.3.3 Wireless indicators Client Mode ......................................................... 12 Safe control 4. 5. Approvals and certifications 5.1 EU Declaration of Conformity ...................................................................... 14 5.2 FCC compliance notice ............................................................................... 14 5.3 RF Exposure compliance ............................................................................ 15 6. Technical specifications 4 5 11 13 14 16 Classified as Business Version log:
Version 0.0 Date 08.12.2021 Comments Document started Initials EGK Classified as Business The wireless Control Panel 1. The main functionality of the wireless CP is to setup and control a drive manually via the build-in menu or/and act as a wireless gateway for this purpose (the wireless option is needed). The application MyDrive Insight can be installed on mobile, tablets, etc. device. Download MyDrive Insight from Google Play, Apple Store or go to Danfoss Drives App Suite. Control Panel 2.8W OPX25: with display, NFC and wireless;
Control Panel 2.8 OPX21: with display and NFC; without wireless;
Wireless Panel OPX01:
without display; with NFC and wireless;
136b7732 136b7731 136b7733 Control Panel 2.8 - OPX21 Control Panel 2.8W OPX25 Wireless Panel OPX01 Classified as Business 2. Installation Instructions Safety and Installation Awareness 2.1 Before starting installation, familiarize yourself with the safety guidelines and precautions in the Safety Guide. For additional information about the control panel, consult Application Guides in the iC7 Series. 2.2 Verifying Shipment and Contents Items Supplied 2.2.1 Make sure that the items supplied consist of any of the following control panel options. Classified as Business Control Panel Compatibility 2.2.2 All iC7 hardware products are compatible with the control panel options either mounted into the cradle in the iC7 drive, or front mounted and connected by a cable. For installation instructions on control panel mounting kits, see iC7 Series Control Panel Mounting Kits. Installing the Control Panel 2.3 Procedure to attach control panel:
1. See illustration 1.11.3 in 2.6.1 Illustrations Result the cradle. The clip makes a click sound when properly aligned. The control panel is now locked into A splash screen is shown during the power-up of the control panel. Check status indicator lights on the control panel. Refer 1.4 Status Indicators. After the control panel is powered on, the Home screen is shown. If security is enabled, the control panel display navigates to an Authentication screen. 2. To use MyDrive Insight, install and launch MyDrive Suite from Google Play, Apple Store or go to Danfoss Drives App Suite. Skip the step, if MyDrive Suite is already installed. 3. Open MyDrive Suite and install MyDrive Insight. Procedure to detach control panel:
1. See illustration 2.12.3 in 2.6.1 Illustrations Classified as Business Status Indicators 2.4 The status of the drive is represented via the Halo and text LED indicators. The Halo and text LED indicators are available on all control panel options. The text LED indicators are Warn, Ready, and Fault. Status indicators:
Classified as Business Installation instruction for best radio reception 2.5 This gives Best Praxis hints for setting up a drive with a wireless Control Panel or the remote placement of a wireless Control Panel. 2.5.1 Wireless CP installed in a drive Best location for a drive with a wireless ICP:
In general, it is good praxis to keep the drive clear from the ground/floor Keep it as clear as possible from other objects, particularly the font side Do not place obstacles in front of the drive If the drive has to be placed inside a cabinet use an extension cable to get the wireless ICP outside the cabinet Avoid places near other radiating devices e.g., router, transmitter, Classified as Business 2.5.2 Wireless CP installed remotely in a cradle Best praxis for a remotely placed wireless control panel in a cradle:
It is good praxis to place the cradle clear from the ground/floor in a vertical position Use only original Danfoss extension cables Keep it as clear as possible from other objects Keep a minimum clearance of 10cm from other cables behind the wireless control panel Do not place obstacles in front of the wireless control panel Avoid places near other radiating devices e.g., router, transmitter, Classified as Business 2.6 Installation Illustrations 2.6.1 Illustrations Classified as Business Connection Procedure 3. Default operation mode is Off but can be configured for Access Point Mode or Client Mode operation from parameter xx-xx-yy WiFi Operation Mode. xx-xx-yy WiFi Operation Mode Access_Point_Mode Client_Mode Off Access Point Mode 3.1 The wireless SSID is Danfoss following the serial number of the iC7 Product. For example, Danfoss-012345678900 is the default wireless SSID for a product with the serial number 012345678900. The serial number can be located on the product label or alternatively from parameter xx-xx-0x Serial Number. Default Password is Danfoss1234 xx-xx-0x AP Wireless SSID Danfoss-012345678900 Open the MyDrive Insight app and establish the Wi-Fi connection, see table for descriptions of the white Wi-Fi LED. When prompted, change the default password due to security restrictions. The password must be at least 8 and maximum 48 characters. If the password is not changed, it leaves only 10 minutes for connecting and performing operations. After this, the wireless connection closes. Reset password If password is forgotten, it can be reset from MyDrive Insight through the NFC interface on the control- or wireless panel or through the Service Port. Client mode 3.2 xx-xx-1x xx-xx-1y CM Wireless SSID CM Password Danfoss-123456789 123456789 Open the MyDrive Insight app and establish connection either wired or wireless. Configure the Client Mode SSID and Password according to the access point Configure Wi-Fi Operation Mode to Client Mode operation Classified as Business 3.3 LED pattern 3.3.1 Status indicators Status Status type Power On Not Ready Ready for operation Fault Warning Winking from external application Panel options Control Panel 2.8W Blinking White (1Hz) On White On Red On Yellow Blinking (Yellow/White/Red) Winking from external Status type Power On Not Ready Ready for operation Fault Warning application 3.3.2 Wireless indicators Access Point Mode Wi-Fi Status Wi-Fi Status type Wi-Fi not active Wi-Fi is active (Devices are connected or not connected) Panel options Control Panel 2.8W LED indicator shows no color. White Halo on control panel. LED indicator shows white color. White Halo on control panel. Wi-Fi Status type Wi-Fi not active Wi-Fi is active (Devices are connected or not connected) 3.3.3 Wireless indicators Client Mode Wi-Fi Status Wi-Fi Status type Wi-Fi not active Wi-Fi is active (Devices are not connected) Wi-Fi is active (Devices are connected) Panel options Control Panel 2.8W LED indicator shows no color. White colored halo on control panel. LED indicator shows white color. White colored halo on control panel. LED indicator shows white color. White colored halo on control panel. Wi-Fi Status type Wi-Fi not active Wi-Fi is active (Devices are not connected) Wi-Fi is active (Devices are connected) Classified as Business Safe control 4. The safe control configuration allows the product to decide the behavior in cases where connectivity is lost from MyDrive Insight to the product through the Wi-Fi interface. This is only applicable when the product is in running operation. xx-xx-2x Wi-Fi Timeout Action Do nothing (Product continues to run) Stop the motor (Generic term to be found because product could be a grid converter or an Active Front End) Classified as Business 5. Approvals and certifications Radio Equipment Directive RoHS Directive: Restriction of the use of certain hazardous substances EU Declaration of Conformity 5.1 The Control Panels comply with the following directives:
2014/53/EU 2011/65/EU The following standards were consulted to assess conformity:
EN 300 328 v2.2.2 EN 300 330 v2.1.1 EN 301 489-1: v2.2.3 -17: v3.2.4 EN 60529:1991+A1:2000+A2:2013 IEC 62368-1: 2018 The CE symbol confirms that this product conforms with the above-mentioned norms and regulations. The complete DoC can be found on Danfoss website: www.Danfoss.com. FCC compliance notice 5.2 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by 1 or more of the following measures:
Reorient or relocate the receiving antenna. Connect the equipment into an outlet on a circuit different from that to which the receiver is Increase the separation between the equipment and receiver. Consult the dealer or an experienced radio/television technician for help. connected. Classified as Business Modifications: Any modifications made to this device that are not approved by Danfoss may void the authority granted to the user by the FCC to operate this equipment. RF Exposure compliance 5.3 FCC Radiation Exposure Statement:
This device complies with FCCs and ICs RF radiation exposure limits set forth for an uncontrolled environment under following conditions:
1. This device should be installed and operated such that a minimum separation distance of 20 cm is always maintained between the radiator (antenna) & users/nearby persons body. 2. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 3. Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Classified as Business Technical specifications WiFi: 802.11 b/g/n BT classic v4.2 BLE v4.2 2.42.5 GHz WiFi < 20 dBm BT < 10 dBm WPA2 (Personal) Access Point or Client
-10 C to +45 C (+14 F to +113F) 590% RH, non-condensing IP20 (IP55 with gasket) 12V +/- 2V, 140mA 122.5 x 77.1 x 15.5 mm (l*w*th) 4.8 x 3.0 x 0.6 in (l*w*th) 112 g 3,91 oz MyDrive Insight V1 or higher Passive tag ISO/IEC 14443, part 2 and part 3 compliant 13,56MHz 6. Wireless Standards:
Frequency range:
Output power:
WiFi security:
WiFi operating mode:
Operating temperature:
Operating humidity:
Ingress protection:
Electrical rating:
Dimensions:
Weight:
Firmware update:
NFC type:
NFC standard:
Frequency:
Classified as Business end