Product overview The package contains LCP-103 as shown below This LCP-103 is be compatible with below drive series, VLT HVAC Drive FC 102 VLT Refrigeration Drive FC 103 VLT Aqua Drive FC 202 VLT Automation Drive FC 300 Features Wireless Technology Built with leading 802.11b/g/n technology Advanced Security - Keep Wi-Fi safe from Internet threats at bay with WEP encryption and standard firewalls to help keep your drive protected LED Indicators LED which help understand the drive behaviour LED Description On Wi-Fi Alarm Warn Field bus indicators Solid Green: Drive is powered-on Blinking White: Device is pairing Solid White: Smart device connected and communication is OK Solid Red: Fault in the drive Blinking Red: Alarm occurred Blinking Yellow: Warning occurred Solid Green: Based on the fieldbus communication MS, NS1, NS2 Winking White: Drive Identification all together MS, NS1, NS2 Installation - Preliminary check-list Step 1: Check whether the drive has new control card (Read drive profile/decode type code) Step 2: Download app MyDrive Connect, available for Android & iOS Google play https://play.google.com/store/apps/developer?id=Danfoss+A/S&hl=en Apple store https://itunes.apple.com/fi/developer/danfoss-a-s/id423984644 Step 3: Power-off the drive if its powered-on Step 4: Mount the LCP-103 hardware in the drives D-9 serial connector (or) Just replace the existing LCP from the drive Begin the connection process Step 1: Power-on the drive, the LCP-103 will glow green LED besides the On Label Step 2: If you are connecting an android device then you shall directly launch the app, (Enable the Wi-Fi service in your smart device before launching) If you are connecting an apple device, then go to settings and then the device will scan and populate the wireless id Step 3: The wireless id is the Danfoss name tagged with serial id of the drive. For example:
Danfoss_019223G455 is the wireless id by default. Step 3: The default password is Danfoss1933, after successful pairing the app will ask you to change the default network id and password. In this case the password is mandatory field, while the network id is an option field. Step 4: You can skip changing the default ids. But this will allow you to connect and perform the drive operations only for 10 minutes, later the drive will close the connection. Step 5: On successful change of ids, your connection will close automatically and you need to reconnect the drive as per step 2. Once gain the app will not ask you to change the password, since you have changed the default ids which is advised due to security risks. Step 6: The app will show the status screen by default, where you will see the current setup id &
all the parameters which was configured earlier through MCT10/LCP-102 Additional Features App MyDrive Connect app is designed with similar navigational structure like LCP-102, hence the initial learning & adaptations are much easier. few more extended functionalities are listed below which helps improve the usability better. 1. Widget Dynamically change the type of widget & also change the parameters 2. Search Parameter search using ID 3. Drive Identification Identify the drive using led winking 4. Push Notification when the app is in background, push notification helps pop-up the alarm & warnings 5. Authentication Allows read/write (or) read parameters 6. Drive Profile Read drive profile 7. Share Logs Share the alarm/warning logs through email 8. Store/Restore Use 0-50 parameter, app uses intelligence and provide various option for copy & restore the setups either to drive or internal memory 9. Disconnect the drive applicable for android devices, once disconnected the LCP-103 will broadcast 10. Vibrate Based on native settings for alarm/warning notifications 11. Graphs All numerical parameters have scope functionality embedded, this helps to poll the read-out values in graph 12. Multi-Language app settings will help change different options (German/English) 13. Demo Mode Helps to learn/demonstrate/promote Hot-Swap/Plug-n-Play The device is ready to connect/how-swap when the drive is powered-on. When you connect to any drive (one to another), the wireless id will be populated from the drive. Hence, the app shall be reconnected to the new network id. 30-9 Group This group will have the special parameters like wireless id, password, safe parameter, which will be saved to the drive. This group is accessible from MCT-10 or Graphical keypad LCP. This is not available in app due to security limits. Safe Parameter option for the user to select the behavior when the app crashes/battery down/connection lost, etc. whether the drive to stop or continue the ongoing process. In case if you need any further assistance, please contact Danfoss representative. Installation Instructions VLT Wireless Communication Panel LCP 103 VLT FC Series FC 102, FC 103, FC 202, FC 301/FC 302, and LD 302 Items Supplied Approvals and CertiOcations VLT Wireless Communication Panel LCP 103. Gasket FCC ID: 2ANSELCP-103 ID:LCP103
Illustration 1.1 VLT Wireless Communication Panel LCP 103 Compatible Drive Series NOTICE Compatible drives have a white USB port. VLT HVAC Drive FC 102 VLT Refrigeration Drive FC 103 VLT AQUA Drive FC 202 VLT AutomationDrive FC 301/FC 302 VLT Lift Drive LD 302 Compatible software versions
-
-
-
-
FC 102: 5.10 FC 103: 2.10 FC 202: 3.10 FC 30x: 8.03 NOTICE FCC COMPLIANCE NOTICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment oR and on, the user is encouraged to try to correct the interference by 1 or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit diRerent from that to which thereceiver is connected. Consult the dealer or an experienced radio/
television technician for help. ModiVcations: Any modiVcations made to this device that are not approved by Danfoss may void the authority granted to the user by the FCC to operate this equipment. RF EXPOSURE COMPLIANCE This portable transmitter with its antenna has shown compliance with FCCs SAR limits for general population/
uncontrolled exposure. The maximum listed SAR level is 0.22 W/kg (body). The antenna used for this device must not be co-located or operating in conjunction with any other antenna or transmitter. Danfoss A/S 06/2018 All rights reserved. MI38V402 Installation Instructions NOTICE
C COMPLIANCE NOTICE VLT Wireless Communication Panel LCP 103 VLT FC Series FC 102, FC 103, FC 202, FC 301/FC 302, and LD 302 Installation
NOTICE The VLT Wireless Communication Panel LCP 103 is hot-
pluggable and can be connected when the drive is powered on. 1. 2. Mount the LCP 103 in the LCP input plug on the drive. Search for MyDrive Connect in Google Play or Apple Store. Illustration 1.2 MyDrive Connect Launch Icon 3. Download and install the MyDrive Connect App. NOTICE Start pairing within the Vrst 10 minutes after the instal-
lation. Failing to do so closes the broadcast or wireless identiVcation due to security limits with default passwords. To reconnect, power cycle the drive, or remove and reconnect the LCP 103. Connection Procedure NOTICE The wireless SSID is the Danfoss serial ID of the drive. For example, Danfoss_019223G455 is the default wireless SSID for a drive with the serial number 019223G455. The serial number is on the product nameplate, but is also visible in parameter 15-51 Frequency Converter Serial Number. Wireless SSID Danfoss_019223G455 Default password Danfoss1933 1. 2. 3. 4. 5. Open the app and establish the Wi-Fi connection, see Table 1.1 for descriptions of the white Wi-Fi LED. When prompted, change the default password due to security restrictions. The password must be at least 8 and maximum 48 characters. Re-plug the LCP 103 for the password to change into e\ect. Failing to do so allows the LCP 103 to keep broadcasting. Disconnect the app, navigate to smart device settings, and forget the network. Search for the wireless network and connect with the new password. 2 Danfoss A/S 06/2018 All rights reserved. MI38V402 Installation Instructions VLT Wireless Communication Panel LCP 103 VLT FC Series FC 102, FC 103, FC 202, FC 301/FC 302, and LD 302 NOTICE If the password is not changed, it leaves only 10 minutes for connecting and performing Drive operations. After this, the wireless connection closes. Reset password If the wireless SSID and password are forgotten, access parameter group 30-9* Wi> LCP via MCT 10 Set-up Software or LCP 102. LED Pattern Pattern Description Solid green LED On Wi-Fi Flashing Connection pairing successful. white Solid white The smart device is connected and communi-
cation is OK. SpeciOcations Standards Frequency range Antenna Security Operating temperature Operating humidity Operating mode Ingress protection Electrical rating Internal memory size IEEE 802.11 b/g 2.4~2.4835 Ghz PCB-mounted chip antenna WPA2
-25 C to +50 C (-13 F to
+122 F) 595% RH, non-condensing Access point / Client IP20 (IP55 with gasket) 5 V, 250 mA 14 MB Weight [g (oz)]
Firmware update 85.3 (2.88) MCT 10 Set-up Software version 4.10 or higher The drive is powered on (normal operation). Dimensions (LxWxD) [mm (in)]
131.2 x 66.6 x 23 (5.1 x 2.6 x 0.9) Alarm Flashing An alarm has occurred. red Warn Solid A warning has occurred. yellow MS, NS1, NS21) Flashing IdentiOcation of the drive when initiated through orange a winking command. Flashing Incompatible drive (LED jashes 3 times and then orange remains on). Table 1.1 Descriptions, LED Indicators 1) MS=module status, NS1=network status 1, NS2=Network status 2. Safe Control The safe control parameter allows the drive to decide the motor behavior if the smart device, for example a tablet, communication is lost. If the limits are set to [1] Stop motor, the motor stops. If the limits are set to [0] Do nothing, the motor continues to run. This is only applicable when the motor is in Run state and if the motor has been started from the app. The communication happens between the MyDrive Connect App and the VLT Wireless Communication Panel LCP 103. Parameter Parameter 30-97 Wi> Timeout Action Limits/options
[0] Do nothing
[1] Stop motor MI38V402 Danfoss A/S 06/2018 All rights reserved. 3