GE Contactless Medium Read-Range Reader Model 260 Installation Guide 791 Park of Commerce Boulevard Suite 100 Boca Raton, Florida 33487
(561) 998-6100 Part Number: 460565001A February 2003 This document contains proprietary information of General Electric Company, USA and is furnished to its customer solely to assist that customer in the installation, testing, operation, and/or maintenance of the equipment described. This document shall not be reproduced in whole or in part nor shall its contents be disclosed to any third party without the written approval of GE Industrial Systems. GE PROVIDES THE FOLLOWING DOCUMENT AND THE INFORMATION INCLUDED TH EREIN AS IS AND WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED STATUTORY WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE. This publication may contain examples of screen captures and reports used in daily operations. Examples include fictitious names of individuals and companies. Any similarity to names and addresses of actual business enterprises and persons is entirely coincidental. Copyright 2003 GE Interlogix, CASI All rights reserved. Printed in the U.S.A MIFARE is a registered trademark of Philips Electronics, N.V. WARNING This is a Class A product. In a domestic environment, this product may cause radio interference, in which case, the user may be required to take adequate measures. Contents Introduction ....................................................................................................... 1 Product Overview............................................................................................. 3 Features ................................................................................................. 3 Access Control System Compatibility .............................................. 3 Mounting Considerations ................................................................................ 5 Environmental Interference ............................................................... 5 Installation on Metal Surface ............................................................. 7 Installation........................................................................................................ 11 Installation: Model 260 on Metal ..................................................... 12 Micro Selection................................................................................... 13 Reader-to-Micro Wiring Distance ................................................... 13 Wiring.................................................................................................. 14 Point-to-Point Wiring Diagrams...................................................... 16 Troubleshooting .............................................................................................. 23 Technical Specifications ................................................................................. 26 Regulatory Notices.......................................................................................... 28 Model 260 Smart Card Reader i Figures Figure 1: GE Contactless Medium Read-Range Reader
(Model 260) .................................................................... 1 Figure 2: GE Model 260 Reader Backplate
(includes tamper switch) ................................................ 2 Figure 3: GE Model 260 Reader Environmental Considerations .. 5 Pole-Mounted Readers .................................................. 7 Figure 4:
Parking Entrance/Exit Application A............................... 8 Figure 5:
Figure 6:
Parking Entrance/Exit Application B............................... 9 Figure 7:
Parking Entrance Exit and Metal Sign Applications ..... 10 Figure 8: Model 260 Reader Backplate and Cover ..................... 11 Figure 9: GE Model 260 Reader Wiring Diagram to Micro/5 8RP 16 Figure 10: GE Model 260 Reader Wiring Diagram to J-Box ......... 17 Figure 11: GE Model 260 Reader to 2RP ..................................... 18 Figure 12: GE Model 260 to 8RP .................................................. 20 Figure 13: GE Model 260 Reader to Micro/Reader 22 Figure 14: Stripping of Shield Grounds ......................................... 28 Junction Box and Microcontroller ii GE Contactless Medium Read-Range Reader Model 260 Introduction The GE Contactless Medium Read-Range Card (Model 260) is the latest evolution in contactless reader 13.56 MHz technology, and features universal compatibility with all ISO 15693 and ISO 14443A badge credentials. The GE Model 260 reader combines simple, cost-effective installation with the end-user convenience of extended read range. The reader housing is a durable gray polycarbonate making the reader equally well-suited for interior and exterior security locations. The reader is easy to install on all types of conventional and metal wall surfaces, stanchions, and pedestal-mount configurations. FIGURE 1: GE Contactless Medium Read-Range Reader (Model 260) GE Contactless Medium Read-Range Reader Model 260 1 FIGURE 2: GE Model 260 Reader Backplate (includes tamper switch) 2 GE Contactless Medium Read-Range Reader Model 260 Product Overview Features
Exceptional read range of up to 14 inches (355.6 mm) for ISO 15693-
compliant credentials. (Read range will vary with credential type and quality, as well as installation environment).
Universal compatibility with all ISO 15693 and ISO 14443A credentials (badges, disc tags, and key fobs).
Supervised four-state (open, closed, wire cut, and wire short) monitoring for door contacts and REX (request to exit) switches, and wiring.
Electrical protection (reverse polarity diode protection on power lines).
Data lines; high-speed transient voltage suppressor diodes
Compatible with Micro/5 2RP and 8RP Reader Processor boards, Micro/PX-2000, and Micro/PXN-2000 controllers
IP 65-rated sealed for deployment in both interior and exterior environments.
Integrated reader tamper protection and microcontroller supervised data communications. Access Control System Compatibility The Model 260 badge reader outputs a 16-digit badge identification (BID) number. As a result, the Model 260 reader is compatible with Picture Perfect while microcontrollers on a Secure Perfect system must be field-
configured for Model 260 compatibility. Picture Perfect Edition Setup Refer to Access/Badge Formats or to the Picture Perfect online help for assistance. A 16-digit BID format must be defined within Picture Perfect. Enter a suitable badge format description. Example: 16-digit BID and define the format: %16S. Secure Perfect Edition Setup The Secure Perfect Edition access control system supports Badge IDs
(BIDs) up to a maximum of 12-digits. Since a Model 260 reader will output a 16-digit BID number, the Secure Perfect microcontrollers must be specifically configured to receive the incoming 16-digit BID number, and convert it into the Secure Perfect-compatible 12-digit BID format. GE Contactless Medium Read-Range Reader Model 260 3 To make a Secure Perfect 4.0 or higher system compatible with the GE Contactless Medium Read-Range Readers, do the following:
Install Secure Perfect Edition, 4.0 or higher
Load the Secure Perfect Update CD in the server CD drive
Locate the Badge Formats folder
In the Badge Formats folder, locate the 15693.REG file
Double-click the 15693.REG to configure the Secure Perfect Edition system and microcontrollers for operation with GE Contactless Medium Read-Range Readers Note: For earlier versions of Secure Perfect Editions, please contact CASI Sales Engineering for the 15693.REG file. This file configures the Secure Perfect Editions system to communicate with the GE Contactless readers. To restore Secure Perfect Editions system back to factory settings, install the BADGE FORMATS.REG file. 4 GE Contactless Medium Read-Range Reader Model 260 Mounting Considerations FOR PROTECTION AGAINST ENVIRONMENTAL INTERFERENCE Model 260 readers require care and consideration in the manner in which they are mounted. This includes consideration of the other equipment and structural elements that are mounted near the reader, whether visible or hidden. The following covers the major factors to consider. Environmental Interference There are three types of environmental interference:
1. Electrical Noise (field wiring related) 2. Field Blocking (conductive material in read field) 3. Overlapping Fields (side-to-side & back-to-back installation) FIGURE 3: GE Model 260 Reader Environmental Considerations Data Network Wiring Light Switch Power Wiring Security Wiring Signs &
Other Metal Objects Door Model 260 Sample Entranceway GE Contactless Medium Read-Range Reader Model 260 5 The reader may encounter a wide range of interference as shown in Figure 3, GE Model 260 Reader Environmental Considerations, on page 5. Common causes include:
Power Wiring Power wiring carries electrical noise that can interfere with the operation of the reader. This is more common with traditional 125 KHz proximity readers. However, this is a potential issue with the GE Model 260 reader, particularly if data noise is introduced by coupling from the readers power wiring. Any power wire may inductively or capacitively couple noise into the reader data line. Data Network Wiring Data network wiring can generate noise, which may possibly be in the operating frequency range of the reader. This noise can interfere with reader-to-credential communication and reduce read range. Security Wiring While not normally a source of noise itself (although it can cause problems if bundled in a loop directly behind the reader), security wiring can inductively or capacitively couple to data or power wiring, and transfer noise to the reader. Signs and Other Metal Objects Signs and other metal objects within the read field of the reader can absorb or block reader-to-credential communication and reduce range. Use shielded cable for reader communication. Reader installation considerations should avoid read field blocking and overlapping conditions. 6 GE Contactless Medium Read-Range Reader Model 260 Installation on Metal Surface Mounting the GE Reader directly on a metal (or other electrical conducting surface) will reduce read range to approximately 9.45 inches
(240 mm). For maximum read-range, ensure the metal wall installation switch is set to the < 0.75 inch position. Another potential source of interference is mounting two or more readers in close proximity as shown in Figure 4. FIGURE 4: Pole-Mounted Readers Front view Side view Vertical separation distance Back-to-back distance The following problems may occur when mounting multiple GE Model 260 readers in close proximity:
The signal energy from one reader may interfere with the read range of the other.
Overlapping read fields can cause a single credential to be read simultaneously by two or more readers. GE Contactless Medium Read-Range Reader Model 260 7 To ensure proper operation and optimal read range, take the following precautions:
1. Mount all readers before tuning any of the readers. 2. Ensure that the back-to-back distance is at least 3.28 feet (one meter). Note: If a metal plate is installed between the two readers, the back-to-back distance restriction may be ignored. However, read range will be reduced to approximately 9.45 inches (240 mm). Note 2: Reduced credential read range and the simultaneous read of a credential by both readers may result if the readers are installed less than 19.68 inches (500 mm) apart. 3. Ensure that the vertical separation distance is at least 19.68 inches
(500 mm). A more narrow vertical separation gap may be used if the simultaneous read of a credential by two or more readers is acceptable. FIGURE 5: Parking Entrance/Exit Application A Back-To-back distance OUT Gate Ctrl Gate Ctrl IN A common use for the GE Model 260 is parking lot applications. However, the parking lot application presents opportunities for all of the interference types as described earlier. 8 GE Contactless Medium Read-Range Reader Model 260 FIGURE 6: Parking Entrance/Exit Application B Reader-Control Gap OUT Readers Gate Ctrl Gate Ctrl IN In Application A, the back-to-back and (if used) vertical gap guidelines above must be observed. Remember to mount all readers (and all other structures) before tuning the reader. In Application B, successful installation requires close attention to electrical noise from the gate control mechanism (and its associated wiring) that may cause reader-to-reader signal interference. GE Contactless Medium Read-Range Reader Model 260 9 FIGURE 7: Parking Entrance Exit and Metal Sign Applications Reader/sign distance OUT Gate Ctrl Readers Gate Ctrl Metal sign IN Signs and other metal objects, including hidden wiring may interfere with the readers read field. Metal signs are common items in both indoor and outdoor installations. The signs may be free standing (see Figure 3, GE Model 260 Reader Environmental Considerations, on page 5) or fixed in position (see Figure 7, Parking Entrance Exit and Metal Sign Applications, on page 10.) To ensure optimal read-range performance, ensure all metal signs and other conductive objects are placed at a distance that is at least:
19.68 inches (500 mm) from the front of the reader.
5.91 inches (150 mm) from the back of the reader.
3.94 inches (100 mm) from the side of the reader. 10 GE Contactless Medium Read-Range Reader Model 260 Installation FIGURE 8: Model 260 Reader Backplate and Cover The cover is secured with four supplied screws (screw hole plugs included). GE Contactless Medium Read-Range Reader Model 260 11 Installation: Model 260 on Metal The GE Model 260 reader can be field-tuned to accommodate installation on or near metal surfaces. To accomplish this, perform the following steps:
1. Remove the front cover. 2. Mount reader back-plate assembly. 3. Terminate the communications cable at the microcontroller using the wiring diagram in Figure 9, GE Model 260 Reader Wiring Diagram to Micro/5 8RP, on page 16 or Figure 11, GE Model 260 Reader to 2RP, on page 18. 4. Terminate the communications cable at the reader using the wiring diagrams in Figure 10, Figure 11, Figure 12, or Figure 13. 5. Wall-type selection switch. Set the two-position slide switch to match the wall surface. 6. Connect the communications cable to power up the reader. IMPORTANT: Within three seconds, you must press the Tune button or the reader will go into tamper operation (red LED flashes). You will be unable to tune the reader in this condition. If this occurs, remove, then reconnect the communications cable. 7. Press the Tune button and release when the reader beeps. 8. Tune the Trim POT until the green LED flashes.
If the yellow LED flashes, turn RIGHT.
If the red LED flashes, turn LEFT. Note: The green LED flashes for approximately six minutes. You can stop the flashing by pressing the Tune button. The yellow LED will be on. The reader will shift into reader-tamper operation (red LED flashes). 9. Install the reader cover. 10. The red LED will stop flashing after approximately 30 seconds. The Model 260 is now tuned and set for optimal read-range for its environment. If new metal components are introduced into the read-range field, you may need to re-tune the reader. Follow the tuning process steps above. 12 GE Contactless Medium Read-Range Reader Model 260 Micro Selection
Micro/5 for 2RP and 8RP installation instructions: refer to the Micro/5 Installation Guide. IMPORTANT: DO NOT use the Model 260 Reader with a Micro/5 2SRP reader processor.
Micro/PX-2000 and Micro/PXN-2000 controllers: refer to the Micro/
PX-2000 and Micro/PXN-2000 Installation Guide.
Micro/Reader-Junction Box: refer to the point-to-point wiring diagrams in this manual. Reader-to-Micro Wiring Distance Table 1: Model 260 Current and Cable Distance Cable Distance Supply Voltage 12 VDC 13.6 VDC 24 VDC Current 18 AWG 22 AWG 18 AWG 22 AWG 18 AWG 22 AWG Distance 230 mA
@12 VDC 928 ft.
(283 m) 390 ft.
(119 m) 1,423 ft.
(434 m) 597 ft.
(182 m) 4,649 ft.
(1,417 m) 1,949 ft.
(594 m) GE Contactless Medium Read-Range Reader Model 260 13 Wiring Table 2: Reader 12-Position Field Wiring Connector Pin Definition 1 2 3 4 5 6 7 8 9 10 11 12 Micro control, reader beeper (option) Ground 8 VDC to 30 VDC Door contact Reader Data 1 Exit request (REX) Green LED Micro control, red LED (option) Reserved for future use Reserved for future use Reserved for future use Reserved for future use 14 GE Contactless Medium Read-Range Reader Model 260 Installation Notes (unless otherwise specified). All numbered items below are referenced on the appropriate wiring diagrams that follow. 1. Fuse, power supply, door strike, protection device, and relay are provided by the installer. The 470 included -watt resistor, must be installed at the Micro/5 2RP terminal block. The Micro PX-2000/PXN-2000 and Micro/5 2RP and 8RP boards do not require this resistor. Shielded cable is recommended in electrically noisy environments. If using shielded cable: At the reader end: connect all shields together and insulate them. At the Micro end: connect the shield to the micro cabinet as indicated in the appropriate Micro Installation Manual. If using a local power supply, do not connect the power (8-30 VDC) line from the microcontroller to the reader. The ground line of the power supply must be connected to the micro (pin 2 on the reader connector). J3 is typically not used in this installation. See Figure 13, GE Model 260 Reader to Micro/Reader Junction Box and Microcontroller, on page 22. Blocking diodes may be 1N4148 or equivalent (installer supplied) and located in a secure area. Protection diodes may be 1N4002, 1N4003, or 1N4004 (installer supplied) for the door strike assembly. Install two 1k -watt resistors (installer-supplied) at Door DI and Exit DI, as shown. 2. 3. 4. 5. 6. 7. 8. 9. 10. Connect a protection device across the door strike. AC Door Strikes: Connect an MOV (metal oxide varistor) across the door strike. (Included with Micro/5 2RP, 8RP, and PX(N)-2000). DC Door Strikes: Connect a diode across the door strike (cathode to positive side of door strike). (Included with Micro/5 2RP, 8RP, and PX(N)-2000). 11. Relay Coil Current Restriction (Micro/5 2RP with external relay). The relay coil current must be limited to 40 mA to prevent damage to the board. Verify that the relay coil requires less than 40 mA. 12 VDC relay: coil resistance must be greater than 300 . The Micro/5 2RP with internal or AUX DO relay current through the relay contacts must be limited to less than 2 A to prevent damage to the 2RP. Current limiting may be achieved by using either a current-limiting power supply or by wiring in an external fuse. 12. Connect protection diode across relay coil. Connect a diode across the relay coil (cathode to positive side of relay coil). General note: Pair wires as shown in all wiring diagrams. GE Contactless Medium Read-Range Reader Model 260 15 Point-to-Point Wiring Diagrams FIGURE 9: GE Model 260 Reader Wiring Diagram to Micro/5 8RP 16 GE Contactless Medium Read-Range Reader Model 260 FIGURE 10: GE Model 260 Reader Wiring Diagram to J-Box GE Contactless Medium Read-Range Reader Model 260 17 FIGURE 11: GE Model 260 Reader to 2RP 18 GE Contactless Medium Read-Range Reader Model 260 Table 3: 2RP Reader Switch Settings Reader Technology and Format SW-1 SW-2 SW-3 SW-4 Supervised F/2F ON OFF ON OFF Table 4: Reader Board 2RP Address Settings Reader Board SW 1 SW 2 5 6 7 8 1 2 3 4 1 2 3 4 ON OFF OFF OFF OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF ON Note: Switches SW2-5, 6, 7, and 8 are not used. Jumper W1 Set to 12 V RN2 and RN5 (labeling) Use 2k (202) resistor packs GE Contactless Medium Read-Range Reader Model 260 19 FIGURE 12: GE Model 260 to 8RP A 4 0 0 5 7 4 0 3 5 20 GE Contactless Medium Read-Range Reader Model 260 Table 5: 8RP Reader Technology and Format Reader Technology and Format SW1-1 SW1-2 SW1-3 SW1-4 Supervised F/2F ON OFF ON OFF Table 6: 8RP Board Address Settings SW 1 Board Type Standard Board 1a Board 2b a. Readers 1 - 8. b. Readers 9 - 16. 5 6 7 8 ON ON Does not apply. ON OFF OFF OFF ON ON Note: the 8RP Reader appears to the Microcontroller as four 2RP boards. SW 2 4 ON OFF 5 ON ON 3 ON ON 6 OFF OFF 7 ON ON 8 OFF OFF ON OFF OFF OFF ON OFF ON Board Type Standard Board 1a Board 2b a. Readers 1 - 8. b. Readers 9 - 16 1 2 OFF OFF OFF ON ON GE Contactless Medium Read-Range Reader Model 260 21 FIGURE 13: GE Model 260 Reader to Micro/Reader Junction Box and Microcontroller 22 GE Contactless Medium Read-Range Reader Model 260 Troubleshooting If the operation of a component is in doubt, substitute a known-good component and retry the system. Always verify wiring against the provided wiring information before powering up the reader. Table 7: Error Conditions and Possible Solutions Condition None of the LEDs are on. The green LED is always on. The green LED indi-
cates that the door strike is open. It is con-
trolled by the input on connec-
tor JP1 pin 7. The door does not open and the green LED does not light when an ISO 15693 or ISO 14443A card is presented. Possible Solutions Present a known-good ISO 15693 or ISO 14443A type card to the reader while listening for the beeper. If the beeper sounds, the reader is faulty and should be replaced. If the beeper does not sound, check the following:
Power connections to the reader Reader supply voltage at connector JP1 pin 3 and that the ground connection JP1 pin 2 is secure Disconnect the wire on JP1 pin 7. If the green LED stays on, the reader is faulty and should be replaced. If the green LED goes off, then the prob-
lem is most likely not in the reader. Reconnect the wire on JP1 pin 7 and measure the voltage at JP1 pin 7. A low voltage (0 to 2 VDC) turns on the green LED. If the voltage is low, there are two possibilities:
A short to ground in the wiring between the reader and microcontroller, or The host system may be energizing the door strike Verify that the door strike and the green LED are wired correctly. Verify that the access card has been entered and that the reader has been properly configured in the host system. GE Contactless Medium Read-Range Reader Model 260 23 Condition Possible Solutions The green LED does not light, but the door strike unlocks the door when a valid ISO 15693 or ISO 14443A card is presented. Verify that the door strike is wired correctly. Refer to the appropriate wiring diagram. Disconnect the wire from JP1 pin 7 (green LED) and connect JP1 pin 7 to JP1 pin 2 (ground). If the green LED is now on, the reader is good and the connection to the reader is defective. If the green LED does not light, replace the reader. Green LED lights but the door does not open. Verify correct door strike wiring and operation. The reader is functioning. If not, check that the block-
ing diode is functioning. If it is not, replace it. Reader sounds a short triple beep every 30 seconds and the red LED flashes slowly
(every 2 sec-
onds). The reader has lost communication with the micro-
controller. Check the reader-to-microcontroller wiring, in par-
ticular, the terminations for Reader Data 1. Refer to the appropriate wiring diagram. Verify that the 2RP AUX DO is jumpered to the reader data 1 on the microcontroller. Jumper between 2RP JP2 and JP4, pins 3 and 7. Verify that the correct pull-up resistor is installed on the microcontroller (470 -watt, 2RP JP2 and JP4, pins 1 and 3). Verify that the microcontroller has the correct firm-
ware. Refer to the manual that came with your microcontroller for instructions. Try the reader on a different reader input port at the microcontroller. If this corrects the problem, the operational status of the original port is sus-
pect. Replace the reader with one you know is working correctly. If this corrects the problem, then the reader is probably faulty and should be replaced. If none of the above steps have identified the problem, there may be a significant noise source present in the installation which is interfering with the reader-to-microcontroller communications. If this is the case, use shielded wire for reader-to-
microcontroller connections. 24 GE Contactless Medium Read-Range Reader Model 260 Condition Possible Solutions The reader sounds a short triple beep every 30 seconds and the red LED flashes quickly
(every 400 ms). The reader sounds a short triple beep every 5 seconds and the red LED also flashes every 5 seconds. Indicates a tamper violation. Ensure the reader is properly attached to its backplate. The red LED will continue to blink for 30 seconds. The reader is ready for use when the yellow LED is steadily on. Check that the 4-state supervised switches are connected with two 1K resistors to the door con-
tact and the exit request inputs or, if the inputs are not used, that resistors are installed at the reader connector:
DI: Pins 2 and 4, 1K REX: Pins 2 and 6, 2K A 470 -watt pull-up resistor is required between 12 VDC and Reader Data 1 on the Micro/
5 2RP (only). GE Contactless Medium Read-Range Reader Model 260 25 Technical Specifications
Cable: Belden (shielded) 8777, 9873, 9773
Agency Certifications: FCC Part 15; CE Mark, and UL 294 (pending)
Color: Gray
Dimensions with backplate (HWD): 11.75 x 11.75 x 1.16 (298.45 x 298.45 x 29.46 mm)
Environmental: Interior or Exterior
Humidity Range: 0 to 95%, non-condensing
Input Voltage Range: 8 to 30 VDC
Index of Protection: IP 65 (IEC 529)
Microcontroller Communications: F/2F supervised door input, REX, and reader communication/power monitoring
Minimum Wiring: 4 conductors
Operating Temperature/Range: -20 to 158o F (-29 to 70o C)
Read Range:
14 in. (355,6 mm) maximum for ISO 15693
7 in. (177.8 mm) maximum for ISO 14443A
Weight: 2.35 lbs. (1.06 kg) Table 8: Current and Cable Distance Cable Distance Supply Voltage 12 VDC 13.6 VDC 24 VDC Current 18 AWG 22 AWG 18 AWG 22 AWG 18 AWG 22 AWG Distance 230 mA
@12 VDC 928 ft.
(283 m) 390 ft.
(119 m) 1,423 ft.
(434 m) 597 ft.
(182 m) 4,649 ft.
(1,417 m) 1,949 ft.
(594 m) 26 GE Contactless Medium Read-Range Reader Model 260 International Standards Microcontroller compatibility Table 9: Functional Specifications ISO 15693 and ISO 14443A Micro/5-PX and Micro/5-PXN with 2RP and 8RP processor boards (incompatible with M/5 and 2SRP board configurations) Micro/PX-2000 and Micro/PXN-2000 Status Indicators Red, Yellow, and Green LEDs and Beeper GE Contactless Medium Read-Range Reader Model 260 27 Regulatory Notices FCC Changes or modifications not expressly approved by GE-Interlogix for compliance could void the users authority to operate the equipment. FCC and CE Compliance. Shield grounds must be stripped back through the knockout hole (strain relief) and grounded to the external ground stud provided on the microcontroller. FIGURE 14: Stripping of Shield Grounds 28 GE Contactless Medium Read-Range Reader Model 260 CE Manufacturers Declaration of Conformity Manufacturers Name:
Manufacturers Address:
EU Representative:
CASI-RUSCO 791 Park of Commerce Boulevard, Suite 100 Boca Raton, FL USA 33487 Interlogix Europe & Africa Excelsiorlaan 28 B- 1930 Zaventum Belgium Product Identification:
Product: GE Interlogix-CASI Medium Read-Range Reader Model Number: 260 Brand: CASI Means of Conformity:
Hereby, CASI-RUSCO, declares that this equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Hierbij verklaart CASI-RUSCO dat het apparoat in overeenstemming is met de essentile eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Par la prsente CASI-RUSCO dclare que l'appareil est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Hiermit erklrt CASI-RUSCO, dass sich diese Ausrstung in bereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999/5/EG befindet". (BMWi) Notices:
Approved for use in the following countries:
A B CZ DK FIN F D GR H IS IRL I LU NL N PL P E S CH GB GE Contactless Medium Read-Range Reader Model 260 29 30 GE Contactless Medium Read-Range Reader Model 260 GE Contactless Medium Read-Range Reader Model 260 31 32 GE Contactless Medium Read-Range Reader Model 260