TSU25DB TSU25DB-PIR Long Distance Reader Wiring and Installation Instructions ts_tsu25db_wi_en_v171209_as_bf_de Art. #896130 PRELIMINARY DB Regulatory Notices Wiring and Installation TSU25DB Europe Hereby, deister electronic GmbH declares that this equipment - if used according to the instructions - is in compliance with the essential requirements and other relevant provisions of the RTTE Directive 1999/5/EC. A full declaration of conformity can be requested at:
info@deister-gmbh.de Approved for use in all European countries. FCC Digital Device Limitations Radio and Television Interference This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and television reception. Caution! Changes or modifications not expressly approved by the manufacturer could void the users authority to operate this equipment. 2 ts_tsu25db_wi_en_v171209_as_bf_de PRELIMINARY Wiring and Installation TSU25DB FCC Notice To comply with FCC Part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden. FCC Radiation Exposure Statement This equipment complies with the FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and the human body. Industry Canada This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe A est conforme la norme NMB-003 du Canada. Copyright 2009 by deister electronic GmbH Disclaimer deister electronic GmbH is not able to supervise the observance of the instructions given in this manual as well as the conditions and methods used during installation, operation and maintenance of the electronic devices and components respectively. Therefore we disclaim liability and reject responsibility for any losses, damages or costs that are caused by misapplication, installation, handling errors or faulty operation or related to the above in any other way. All our products are subject to current advancement, therefore we reserve the right for modifications without prior notice. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of deister electronic GmbH. deister electronic GmbH reserves the right to make changes to any and all parts of this documentation without obligation to notify any person or entity of such changes. Dezember 2009 IO/DE/SK/MP deister electronic GmbH Hermann-Bahlsen Str. 11 30890 Barsinghausen Germany Phone: +49 (0) 51 05 - 51 61 11
+49 (0) 51 05 - 51 62 17 Fax:
info.de@deister.com E-Mail:
Web:
www.deister.com ts_tsu25db_wi_en_v171209_as_bf_de 3 PRELIMINARY DB Wiring and Installation TSU25DB 1. Technical Data Dimensions:
mm (inch) W x H x D 278 x 238 x 86 (11 x 9.4 x 3.4) Weight:
kg (lbs) 2,5 (5.5) Housing Material:
ABS/PMMA, Al Protection Class:
IP 65 Operating Temperature: -30 C...+60 C
-22 F...+140 F Relative Humidity:
5 %...95 %, non-condensing Power Requirement:
12...28 VDC / max. 1 A Transmission Frequency: 865 868 MHz (EU) or 902 928 MHz (US) or 953 956 MHz (JP) Radiated Transmit Power: max. 1.6 W E.R.P.
(ETSI EN 302 208) or max. 2.6 W E.I.R.P.
(FCC Part 15), configurable Transponder Protocols:
ISO18000-6 C (EPC Class1 Gen2) Reading Distance:
in m (ft.) up to 4 (up to 13) Interface:
RS485 with deBus protocol Electrical Connection:
M12-connector with 4 Pins Conformity:
Air interface (EU) Air interface (US) EN 50346 EN 301489 EN 302208 v1.2 FCC Part 15 4 ts_tsu25db_wi_en_v171209_as_bf_de PRELIMINARY Wiring and Installation TSU25DB 2. Mechanical Dimensions All dimensions in mm [inches]. 2.1 Side View 2.2 Front View 2.3 Rear View Attention! M6 Metric Screws only!
ts_tsu25db_wi_en_v171209_as_bf_de 5 PRELIMINARY DB Wiring and Installation TSU25DB Installation Notes 3. Wiring 3.1 1) Attention:
When installing the reader, make sure the tab connector (as shown) is professionally grounded with a yellow/green, flexible line with at least 0.75 mm (0.11 inch) (18 gauge) cross section. connect here for grounding 2) Attention:
The TSU25DB has fixed built-in termination resistors which cannot be switched off and is therefore suited for connection not for multi-drop use. It can only be operated at the end of an RS485-bus (Point to Point). If an installation is wanted with more than one TSU25DB on the same bus, a SIC2 is needed. For more information about regarding multiple reader installations with TSU25DB please contact your local sales and service partner. 3.2 Pin Assignment The TSU25DB has an M12-connector (male) with 4 pins. The pin assignment is as follows:
PIN 1 2 3 4 Description
+Vcc RS485-A GND RS485-B 4. LEDs and Beeper The standard settings for the LEDs and the beeper are as follows:
LED/Beeper Action Visualisation Yellow LED short blinking long blinking constantly on off for a short time Green LED Red LED Beeper user defined user defined user defined Status TSU25DB field is switched off reader is not polled field is switched on tag read user defined malfunction and user defined user defined 6 ts_tsu25db_wi_en_v171209_as_bf_de PRELIMINARY Wiring and Installation TSU25DB 5. Mounting 5.1 Mounting on poles and pipes For mounting on poles/pipes you need to fix the base plate for mast mounting LRM3
(optional, see chapter 5.1.1. Mounting the base plate for mast mounting LRM3) to the back side of the TSU25DB first in order to keep the reader adjustable vertically or horizontally. The serrated back plate of the LRM3 guarantees that the reader can be firmly mounted and adjusted 360 around a pole/pipe. For more flexibility in mounting and adjusting the reader on a poles or pipes we recommend the use of our ball joint bracket LRM1 (optional, see chapter 5.2.1. Mounting with ball joint bracket LRM1). 5.1.1 Mounting the base plate for mast mounting LRM3 5.2 Mounting on walls and ceilings For mounting on walls or ceilings the ball joint bracket LRM1 (optional, see chapter 5.2.1. Mounting with ball joint bracket LRM1) can be mounted directly onto the back of the reader. This mounting aid allows to adjust the reader in any desired position. Both ends of the ball joint bracket are ball-beared and connected via a rotatable axis. The desired position can be fixed with an Allen wrench. 5.2.1 Mounting with ball joint bracket LRM1 ts_tsu25db_wi_en_v171209_as_bf_de 7 PRELIMINARY DB Wiring and Installation TSU25DB 5.3 Function Principle and Environmental Influences The reader sends a high-frequent carrier signal. A transponder which is located within the area of this transmitted carrier transmits the signal back with its own transponder data in a modulated way. This very weak signal is being analyzed by the reader. Because of the particular small-bandwidth and the high carrier frequency within MHz-
range this system is almost fail-safe. Nevertheless the range of the reader can be negatively influenced. The following list shows what to pay attention to:
1. The reader must have visual contact to the transponder. There must not be any walls or other devices between reader and transponder. Reading through plastic film, card board, papers or glass windows may be possible in some cases, but will reduce the reading range depending on the condition of the material. 2. Water, ice and snow will absorb the carrier signal. Therefore the installer should take care, that the front of the reader as well as the transponder can not be covered with water, ice or snow. 3. Reflexions within the surrounding of the reader can influence the reading result in a negative way. Therefore the reader should be mounted as free-standing as possible. We strictly discourage from sunk-in installations. 5.4 Radiation Patterns of the Transmitting Antenna 5.4.1 Cutting Plane Diagram The following diagram shows a perspective view of the TSU25DB in order to help assigning the following cutting planes to the orientation of the reader within space. 8 ts_tsu25db_wi_en_v171209_as_bf_de PRELIMINARY Wiring and Installation TSU25DB cutting plane:
polarization:
xz vertical cutting plane: yzxz polarization: vertical cutting plane:
polarization:
xz horizontal cutting plane: yz polarization: horizontal ts_tsu25db_wi_en_v171209_as_bf_de 9 PRELIMINARY DB Wiring and Installation TSU25DB 6. Configuration Configuration of the device is done in the tranSpeed Config software. If the device is operated via an IDC, configuration is done in the tranSpeed Commander Software. 7. Accessories Article Description Article No. CC2 CC4 CC4 LRM1 LRM3 AC/DC power supply Euro AC/DC power supply International AC/DC Power Supply SNG3 Smart Network Gateway DBC IDC SIC1 SIC2 SIC3 Connection cable, grey, 3 m, M12 female connector, straight, 4-pin Connection cable, grey, 3 m, M12 female connector, straight, 4-pin to 4-pin Phoenix connector Connection cable, grey, 10 m, M12 female connector, straight, 4-pin to 4-pin Phoenix connector Ball joint bracket Base plate for mast mounting Power supply for expansion module, input voltage 230 VAC, output voltage 12 VDC (1 A), Friwo plug Power supply, input voltage 100-230 VAC, incl. adapter for USA/Japan and United Kingdom, output voltage 12 VDC (1.25 A), Friwo plug Power supply for c-rail mounting, input voltage 90-260 VAC, 50-60 Hz output voltage 24 VDC (2.5 A) Interface converter USB-to-RS485, incl. USB interface cable, power supply with standard deister power supply 12 VDC, Friwo plug deBus Converter, Interface converter for deBus components, power supply 10-30 VDC Controller for the connection to deBus-readers power supply 10-30 VDC Serial Interface Converter from RS485/deBus protocol to Open Collector/Wiegand, Dataclock, Magstripe protocol, power supply 10-30 VDC Serial Interface Converter from RS485/deBus protocol to RS485/customized protocol, power supply 10-30 VDC Serial Interface Converter from RS485/deBus protocol to RS232, power supply 10-30 VDC 9287.101 9287.301 6236.000 6103.000 6106.000 8812.000 6757.000 6756.000 8782.000 6232.000 6230.000 6233.000 6234.000 6235.000 Table 1: Accessories for TSU25DB 10 ts_tsu25db_wi_en_v171209_as_bf_de PRELIMINARY Wiring and Installation TSU25DB Notes:
ts_tsu25db_wi_en_v171209_as_bf_de 11 PRELIMINARY deister worldwide Germany:
deister electronic GmbH Hermann-Bahlsen Str. 11 30890 Barsinghausen Tel.: +49 (0) 51 05 - 51 61 11 Fax: +49 (0) 51 05 - 51 62 17 info.de@deister.com www.deister.com Canada:
Deister Electronics Inc. 4-1550 Kingston Road, Suite 1411 Pickering, Ontario, Canada L1V6W9 Tel.: +1 905 - 837 5666 Fax: +1 905 - 837 0777 info.ca@deister.com Japan:
deister electronic Japan, LTD. Toshiba Hoshikawa Bldg. 4F 2-4 Kawabe-ch Hodogaya-ku, Yokohama-shi Kanagawa, 240-0001 Tel.: +81 (0) 45 340 1831 Fax: +81 (0) 45 340 1801 info.jp@deister.com USA:
Deister Electronics USA, Inc. 9303 Grant Avenue Manassas, VA 20110 Tel.: +1 703 - 368 2739 Fax: +1 703 - 368 9791 info.us@deister.com Benelux:
deister electronic office Business Park E 19 Battelsesteenweg 455/A 2800 Mechelen Tel.: +32 (0) 15 - 28 09 68 Fax: +32 (0) 15 - 28 09 71 info.be@deister.com France:
deister electronic france 101 rue Pierre Semard 92320 Chatillon Tel.: +33 (0) 1 47 - 35 78 78 Fax: +33 (0) 1 47 - 35 92 59 info.fr@deister.com Great Britain:
deister electronic (UK) Ltd. Stapleton Way, Enterprise Park Spalding, Lincolnshire PE11 3YQ Tel.: +44 (0) 1775 - 717100 Fax: +44 (0) 1775 - 717101 info.uk@deister.com The Netherlands:
deister electronic office Tolnasingel 3 2411 PV Bodegraven Tel.: +31 (0) 1726 - 32970 Fax: +31 (0) 1726 - 32971 info.nl@deister.com PRELIMINARY