DeLaval milking automation BM213 BM204 IOM200 IOM400 CCM215 DM223 Instruction Book Document number: Dnnnnnnnnnnnnnnn 1 | P a g e Table of contents 1 2 2.1 2.2 3 4 4.1 4.2 4.3 4.4 4.5 4.6 5 Safety precautions Regulatory FCC Statement ISED Canada Statement General description Function description General technical data Technical Data BM213, BM204, IOM 200 Technical Data DM223 Technical Data IOM400 CCM215 Photographs Standards 3 6 6 6 7 7 7 8 8 9 9 10 12 2 (12) 1 DeLaval milking automation, BM213 BM204 IOM200 IOM400 CCM215 DM223 1. Note to operator Safety precautions It is the operator's responsibility to see that any person involved with the use or operation of this equipment follows all safety and operational instructions. Under no circumstances should this equipment be used if the equipment is faulty or the operator does not completely understand the operation of the equipment. 2. Disclaimer The information, instructions and parts listed are applicable and current on the date when issued. DeLaval reserves the right to make changes without notice. 3. Definitions of admonishments Admonishments are safety related warning messages. Admonishments provide important information intended to prevent incorrect or hazardous use of equipment, machinery or software, and support risk assessment. The following list defines the different types of admonishments used in DeLaval documentation:
Danger: Refers to imminent and severe risk. Failure to comply with instruction will result in serious injury or death. Warning: Refers to a potential but severe risk. Failure to comply with instruction could result in injury or death. Caution: Refers to a limited risk. Failure to comply with instruction could result in minor injury. Mandatory: Refers to an action or behavior which is essential to safe and successful use of the equipment. Prohibited: Refers to an action or behavior which is incompatible to safe and successful use of the equipment. Note! Is intended to draw attention to specific points of importance in the text and advice to prevent equipment damage. 3 (12) 4. Safety regulations 4 (12) 5. Safety labels on the equipment 5 (12) Regulatory FCC Statement 2 2.1 NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Changes or modifications to the equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from any persons and must not be co-located or operating in conjunction with any other antenna or transmitter. 2.2 This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes : (1) lappareil ne doit pas produire de brouillage ; (2) lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. ISED Canada Statement 6 (12) General description 3 The milking automation family (currently) consist of the modules BM213, BM204, IOM 200, IOM400, CCM215, DM223. All units have the same technical base, when it comes to supply voltage (24V DC), physical dimensions and mechanical interface (footprint). All devices in the family are equipped with a blue tooth radio (BLE 4.2) and all modules have the same environmental class, IP56 However all modules have their area of use. 4 4.1 Function description General technical data Operate at 24VDC +10% and -20%. Supply from LPS Power consumption, max 7W Temperature range +4 C to + 40 C Dimensions 120*107*51 mm IP class 56 RF CHARACTERISTICS OF THE TRANSMITTER Frequency range Number of channels Channel BW Category Classification Operating modes Types of modulation Rated output power 2402 2480 MHz (ISM band) 40 1 MHz Receiver category 2 Equipment for fixed use Transceiver GFSK Maximum 4 dBm EIRP 7 (12) BLOCK SCHEMATIC CYPRESS PSoC4 WITH BLE RADIO Technical Data BM213, BM204, IOM 200 Not valid for SPM006 4.2 The BM213 IOM200 and BM204 are based on the same electronic board and design
(PCBA), differences are within the setup of buttons and application software. All I/O and interfaces are the same. Name BM213 BM204 IOM200 I/O 12 Input/output channels, BLE radio 12 Input/output channels, BLE radio 12 Input/output channels, BLE radio Buttons 1 large 3 small 4 small None Technical Data DM223 4.3 The DM223 is a display unit for MMI communication B/W display and touch buttons 8 (12) Name DM223 I/O 12 Input/output channels, BLE radio MMI 3 Touch buttons and a B/W display 4.4 The usages IOM400 is controlling different motor applications, typical feeding applications. Technical Data IOM400 Name IOM400 I/O 12 Input/output channels, BLE radio MMI None CCM215 4.5 The CCM215 are used for linking local buses (Lin bus) from multiple modules, typical on 1 bus you connect 3 pcs. of BM213 modules + 3 pcs. of IOM200 + 3 pcs. of DM223 so you get 9 units on 1 bus (maximum 10 devices on one bus is allowed). All local busses are then connected to 1 Ethernet bus, via a 10mbit RJ45 connector. Typical you connect up to 45 devices to 1 CCM215. Name CCM215 I/O 1 Ethernet + 5 Local bus MMI None 9 (12) Photographs 4.6 Photographs of the modules Front picture of the IOM200/CCM215 and BM213 IOM200 / IOM400 / CCM215 BM213 10 (12) DM223 BM204 11 (12) Picture of the back of the modules IOM200/IOM200 CCM215 BM213/BM204/DM223 5 Standards RED 2014/53/EU Annex 5 Electromagnetic Compatibility Radio Characteristics Information technology equipment Safety FCC IC, Canada EN 301 489-01:V2.1.1 (2017-02) EN 301 489-17:V3.1.1 (2017-02) EN 55032:2012 + AC:2013 ETSI EN 300 328 v2.1.1 (2016-11) IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013 FCC Part 15.247 Frequency Hopping Transmitters / Digital Transmission Systems Industry Canada RSS-247, Issue 2 Low Power License-Exempt Radio communications Devices 12 (12)