HCND V4 Bridge HCND-V4 Bridge is a rugged programable gateway for secure wireless applications. It offers BLE 5.1, ANT, WiFi and wired Ethernet. Providing an integrated, secure embedded application environment between connected sensors using ANT and the cloud. For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 1 of 19 HCND V4 Bridge Features General Input: DC 5.0V, 2.5A micro USB, PoE (802.3af) Supports more than 50 devices / sensors Supports firmware upgrade Over-The-Air (OTA) Power LED (1) and Status Indicator LEDs (3) Multi-purpose Button Ethernet Gigabit Ethernet Supported WiFi Wi-Fi (802.11.b/g/n), 2.4 GHz band BLE BLE 5.1 Support (Hardware nRF52840) BLE Long Range Support Onboard Power Amplifier for extended range Power This bridge supports one of two power options. You can choose:
Using +5.1V / 2.5 A power supply adapter. Using Power through the Network Port (PoE). Contact your system network administrator for this option. For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 2 of 19 HCND V4 Bridge Bridge Plug in and Power Up 1. Screw BLE/ANT Antenna and WiFi Antenna into socket and Align it to upright position. 2. Plug Ethernet cable (Cat6) from router into Network Port. 3. This bridge supports one of two power options. You can choose:
i. Using +5V / 2.5 A power supply adapter. ii. Using Power through the Network Port (PoE). Contact your system network administrator for this option. For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 3 of 19 HCND V4 Bridge Note:
DHCP must be enabled in the Router connected with Bridge. Bi-directional Internet Traffic for Remote Ports 80, 443, 8883 must be enabled for Bridge. Remote Ping to servers www.google.com and www.yahoo.com: must be enabled for Bridge. For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 4 of 19 HCND V4 Bridge RESET Switch The physical button on the bridge panel that also has the USB and Ethernet ports can be used in the following way:
Press and hold the button for 5 seconds. This will cause the bridge to reset its knowledge of which devices it manages. It will contact the cloud to reset this knowledge as appropriate. Note:
This button DOES NOT reset all configuration settings on the bridge, ONLY the local knowledge of what devices it should manage. Use the iOS configuration app to accomplish this. This button DOES NOT restart the bridge. Use the iOS configuration app to accomplish this. For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 5 of 19 HCND V4 Bridge LED Status Indicator You can use the status lights on the top of the Bridge to verify its status. The green light is indicates power and should always be on. For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 6 of 19 HCND V4 Bridge Network Configuration The purpose of this to provide brief idea for finding information required to connect SR Bridge in secured LAN. Required Port Information for Firewall Settings The HCND V4 bridge uses network connections on the following ports:
Port Number Protocol Service firewall must unblock outgoing port 80 443 8883 53 67 68 123 TCP TCP TCP TCP UDP UDP UDP Provisioning Provisioning MQTT DNS DHCP DHCP ntp yes yes yes yes no no yes For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 7 of 19 HCND V4 Bridge Bridge / Sensor Add in User Account Portal URL: https://sloan-argos-dev1.securemote.com/SignIn Sign-in Credentials:
Email Address: [email protected] Password: password For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 8 of 19 HCND V4 Bridge After successfully login, Dashboard will be displayed. User needs to click on Add a Device option from left navigation pan. User needs to enter Serial Number and Security Token information of the Bridge / Sensor which he /
she wants to add in account. User can find Serial Number and Security Token information from Label received with Bridge / Device. Please see below image:
Note: When Bridge is added in Account then wait for 1 minutes and then verify all LEDs except Green are off. For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 9 of 19 HCND V4 Bridge Check Bridge / Sensor Status on Sloan Argos Portal For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 10 of 19 HCND V4 Bridge 1. Select Manage Devices option from side navigation pane. 2. User can search Bridge / Sensor by location or Serial Number. 3. Search Results will display basic information like Serial Number, SKU Type and Condition of the Device. If everything is ok then it displays Green Color Icon. 4. User can click on Bridge / Sensor to Open Detail Information Page. 5. User can change settings for specific Sensor, Check current Status, other Information from the Device Information Screen. Mobile App User can download Mobile App only for iOS. User can do Firmware Upgrade using this Mobile App. URL: https://apphost.securemote.com/appstaging/iOS/sloan/sloaninternal.html App: Install SR Smart App V. 1.2.0 (Build V. 1.2.1) for Development Env. Note: First Time users needs put Belwith Products in Trusted List by going into Phone Settings ->
General -> Device Man-ager For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 11 of 19 HCND V4 Bridge SR Bridge Network Configuration Use the SC Argus Pro iOS Configuration app to scan for Bridges in the local area. Find MAC Address to use with MAC based Network Filtering After selecting the relevant bridge, tap on the Advanced Details option. For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 12 of 19 HCND V4 Bridge Find the MAC Address based on your network configuration. For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 13 of 19 HCND V4 Bridge Be aware there are separate entries for the MAC Address of the Bridge when it is configured to use Ethernet versus WiFi. Update Cloud Server URL After selecting the relevant bridge, tap on the Cloud Server option. For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 14 of 19 HCND V4 Bridge Enter the URL for the relevant environment the bridge will be working within. For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 15 of 19 HCND V4 Bridge For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 16 of 19 HCND V4 Bridge HCND-V4 Product Specification
[A] Network Controller:
BPI P2 Zero uses as a Network controller and it is used to manage all modules connected with it. It provides communication between cloud and BL654PA via Ethernet/WiFi on different networking protocols like TCP/IP, UDP, HTTP, MQTTs etc. Network Controller uses AES 128-bit secure data connection. It is also used to provide support for Mini Cloud, so when Internet is not available at that time it takes role of Cloud and pro-vide all information to Connected devices.
[B] BL654PA Module:
DSU840PA Module is used to create and maintain SR-Network based on ANT protocol and BLE protocol. It can support network up to 240 SR-Devices on ANT protocol and support network up to 100 SR-Devices on BLE protocol. It also has BLE support to communicate with the Smart Phone App or any other BLE enabled Devices. Internal Block Diagram:
For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 17 of 19 HCND V4 Bridge Specification:
For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 18 of 19 HCND V4 Bridge Software:
For more details please feel free to contact Technical Support at: [email protected] Copyright 2025 Delphian Systems, LLC 19 of 19 FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Caution: Any changes or modications to this device not explicitly approved by manufacturer could void your authority to operate this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF Exposure Information This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. ISED Statement English:This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canadas licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device. The digital apparatus complies with Canadian CAN ICES-3 (B)/NMB-3(B). French: Cet appareil contient des metteurs/rcepteurs exempts de licence qui sont conformes aux RSS exempts de licence d'Innovation, Sciences et Dveloppement conomique Canada. L'exploitation est soumise aux deux conditions suivantes :
(1) Cet appareil ne doit pas provoquer d'interfrences.
(2) Cet appareil doit accepter toute interfrence, y compris les interfrences susceptibles de provoquer un fonctionnement indsirable de l'appareil. l'appareil numrique du ciem conforme canadien peut - 3 (b) / nmb - 3 (b). This device meets the exemption from the routine evaluation limits in section 6.6 of RSS 102 and compliance with RSS 102 RF exposure, users can obtain Canadian information on RF exposure and compliance. cet appareil est conforme l'exemption des limites d'valuation courante dans la section 6.6 du cnr - 102 et conformit avec rss 102 de l'exposition aux rf, les utilisateurs peuvent obtenir des donnes canadiennes sur l'exposition aux champs rf et la conformit. This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. Cet quipement est conforme aux limites d'exposition aux rayonnements du Canada tablies pour un environnement non contrl. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Cet quipement doit tre install et utilis une distance minimale de 20 cm entre le radiateur et votre corps. nuisibles aux systmes mobiles par satellite cocanaux. This radio transmitter has been approved by Industry Canada to operate with the antenna types listed with the maximum permissible gain indicated. Antenna types not included in this list, having again greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Le prsent metteur radio a tapprouv par Industrie Canada pour fonctionner avec les types d'antenne numrs ci-dessous et ayant un gain admissible maximal. Les types d'antenne non inclus dans cette liste, et dont le gain est suprieur au gain maximal indiqu, sont strictement interdits pour l'exploitation de l'metteur.