Issue Department:Bedding Division
System Instruction
Date:
Author:
2017-8-15
Instruction of RF5017
Instruction of RF5017
Edition:
1.1
Page 1 of 5
Figure 1 button ofremote
1 / 5
Issue Department:Bedding Division
System Instruction
Date:
Author:
2017-8-15
Instruction of RF5017
Edition:
1.1
Page 2 of 5
1.1 ZG button(button 1 in figure 1)
Click the ZG button, the actuator moves to ZG position, stop when click any button during the
movement;
Press and hold the ZG button for 5s, timer LED of remote flashes, the control box records
current position as ZG position;
When in the process of moving to memory positions, the head and foot actuators move first,
then the tilt and lumbar actuators move;
1.2 AntiSnore button(button 3 in figure 1)
Click AntiSnore button, actuators move to AntiSnore position, stop when click any button
during movement;
Press and hold AntiSnore button for 5s, timer LED of remote flashes, the control box records
current position as AntiSnore position;
When in the process of moving to memory positions, the head and foot actuators move first,
then the tilt and lumbar actuators move;
1.3 TV/PC button(button 4 in figure 1)
Click TV/PC button, actuators move to TV/PC position, stop when click any button during
movement;
Press and hold TV/PC button for 5s, timer LED of remote flashes, the control box records
current position as TV/PC position;
When in the process of moving to memory positions, the head and foot actuators move first,
then the tilt and lumbar actuators move;
1.4 LOUNGE button(button 6 in figure 1)
Click LOUNGE button, actuators move to LOUNGE position, stop when click any button
during movement;
Press and hold LOUNGE button for 5s, timer LED of remote flashes, the control box records
current position as LOUNGE position;
When in the process of moving to memory positions, the head and foot actuators move first,
then the tilt and lumbar actuators move;
2 / 5
Issue Department:Bedding Division
System Instruction
Date:
Author:
2017-8-15
Instruction of RF5017
Edition:
1.1
Page 3 of 5
1.5 Reset all memory positions to default settings(button 1 and 11 in figure 1)
Pressa and hold ZG+FLAT buttons(button 1 and 16 in figure 2)for 5s, timer LED of
remote flashes, the control box reset all memory positions to default settings;
1.6 Head up(button 7 in figure 1)
Press and hold HEAD UP button of remote, head actuator moves out, stop when
released;
1.7 Head down(button 9 in figure 1)
Press and hold HEAD DOWN button of remote, head actuator moves in, stop when released;
1.8 Foot up(button 8 in figure 1)
Pressa and hold FOOT UP button of remote, foot actuator moves out, stop when released;
1.9 foot down(button 10 in figure 1)
Press and hold FOOT DOWN button of remote, foot actuator moves in , stop when released;
When moving to flat position, lumbar actuator and tilt actuator move first, after 500ms, head and
foot actuators start moving;
1.10
Flat(button 11 in figure 1)
Click FLAT button, the bed goes flat, stop when click any button during the process of going
flat;
1.11 Massage head(button 12 in figure 1)
Click MASSAGE HEAD button, head massage motor switches massage intensity, massage
intensityswitches among 0-1-2-3;
3 / 5
Issue Department:Bedding Division
System Instruction
Date:
Author:
2017-8-15
Instruction of RF5017
Edition:
1.1
Page 4 of 5
1.12 Massage timer(button 13 in figure 1)
If the massage motors do not work, the button is invalid, if the massage motors work, click the
button to switch the massage time, when massage time switch to 0, turn off the massage;
1.13 Massage ON/OFF(button 15 in figure 1)
Click Massage ON/OFF button, if the massage motors are on, then it turns off massage
motors,if massage motors are off, then it turns on the massage motors;
1.14
Under bed light(button 16 in figure 1)
Click the under bed light button, the under bed light switch its on/off state; After the under bed
light opens, if do not manually close, it will automatically turn off after 5 minutes;
1.15 Massage Type(button 17 in figure 1)
Click massage type button, to switch the massage mode og massage motors, massage mode
switches among type0type1type2type3type0; this button can only switch the massage
mode, it can not open massage motors;
4 / 5
Issue Department:Bedding Division
System Instruction
Date:
Author:
2017-8-15
Instruction of RF5017
Edition:
1.1
Page 5 of 5
FCC Warning:
Please take attention that changes or modification not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
ISED RSS Warning:
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions:
(1)
(2)
operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1)
(2)
brouillage est susceptible d'en compromettre le fonctionnement.
this device may not cause interference, and
this device must accept any interference, including interference that may cause undesired
l'appareil ne doit pas produire de brouillage, et
l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
5 / 5