INSTRUCTION MANUAL Radio-controlled weather station
.Intended use Thisradio-controlled weather station displays the indoor and outdoor temperature,indoor and outdoor humidity ,and barometric pressure. It features a radio-controlled clock and several alarm functions. The probable weather trend is calculated based on data collected.This product is not intended for commercial us Features:
1. Time,date,month 2. 3. outdoor temperature 4. Day of the week in 8 languages Indoor temperature and humidity
(English,Italian,French,German,Dutch,Spanish,Danish,Russian) 5. Double alarm 6. Snooze function 7. Blue backlight 8. 12/24 hour selectable 9. Year range:2000~2099 10. C/F selectable 11. Radio controlled clock with DCF 12. Lower power indicator 13. Air pressure 14. Air pressure barchart 15. Sun rise and sunset time 16. Mo0n rise and moon set time 17. Comfort level display 18. Time zone Technical Data Base station:
Temperature measurement rang: 0 to 50 Humidity measurement rang: 20% to 95%
Barometric pressure : 900hPa to 1050hPa Batteries: 3x LR03, 1.5V
(size AAA) Humidity accury:+/- 8%
Temperature accuracy: +/- 1.5 C at 0-+39C Temperature accuracy: +/-2 C at 40C-50c Sensor Temperature measurement range: -20 to 60 Humidity measurement range: 20% to 95%
Data transmission frequency : 433.91MHz Batteries: 2XLR03,1.5V
(SIZE AAA) Range about 60M in open air Temperature accuracy: +/- 1.5 C at 10-+40C Temperature accuracy: +/-2 C at 40C-60C, -20C~10C Battery operation 1.Open the battery cover at the back of the base station insert3 XAAA batteries 2.When changing batteries first remove the old batteries.Insert the new batteries,type LR03,in the battery compartment.check the polarity of the battery during the insertion.this is indicated in the battery compartment. 3.Close the battery cover. Starting the base station After insert batteries, The display will briefly light up and run a brief check of all display elements. 1. The weather icon will flash,you can press -/MAX/MIN/- or+/AIR PRESSURE to adjust, press HISTORY/WEATHER to confirm 2. The outdoor temperature field will show an animation of reception symbol
,indicating the base station is searching for the signal from the outdoor sensor. 2.If no outdoor temperature is displayed after 3 minutes,the base station will stop searching,the animation of the reception symbol will turn off and the outdoor temperature field will show--.-
3.Most likely ,the signal cannot be received due to structural factors,reinforced concrete walls,the brick work being too solid or the distance between the units.After finding the better location for the outdoor sensor ,reception will need to be restarted. 4.3minutes later ,then the weather station will automatically start receiving the DCF radio signal ,regardless if signal from the outdoor sensor was received or not.The clockwill show an animated radio tower icon
,indicating the receiver for the DCF signal is start to received the time. 5.If the signal is detected the clock displaywill show the current central European time,date and day of the week.A static radio tower signal appears. 6.If the attempts of receive a signal fail the base station will stop attempting to receive a signal after10 minutes and the radio tower signal will disappear. 7.You may reactivate reception by press and holding the -/MAX/MINbutton for three seconds until an radio tower signal in the clock displaybecomes animated.you also have the option to set the time manually. 8. HOLD +/AIR PRESSUREand-/MAX/MIN to exit RCC function. Then LCD. HOLD +/AIR PRESSUREand-/MAX/MIN again to turn on RCC. displayonthe Time setting:
1. Hold the MODE button for 3second enter into time setting 2.The setting item will flash 3. The sequence:
C/F selection-mb/hPA selection-12/24 hour-Time zone-hour-minute
-second -YearMonth-Date -language -country -city 4.Press -/MAX/MIN/- or+/AIR PRESSUREto adjust the setting item Alarm Setting Press MODE to select alarm 1 or alarm 2. The corresponding alarm symbols will appear. When display alarm 1 or alarm 2, press and hold MODE button to enter into setting mode. The hours will blink on the display. Set the hours by pressing +/AIR PRESSURE or-/MAX/MINand confirm your setting by pressing MODE button. Set the minutes in the same way. Alarm on/off Alarm 1 on/ off At standard displaying mode, press MODE to switch to alarm 1 display mode. Then you iconflashandalarmon/offstatusontheseconddispayarea.Press+/AIR will see PRESSUREor-/MAX/MINto turn on/off alarm 1. When it is set to be on, after exit, alarm 1 willbedisplayontheLCD. Alarm 2 on/ off At standard displaying mode, press MODE to switch to alarm 2 display mode. Then you iconflashesandalarmon/offstatusontheseconddispayarea.Press+/AIR will see PRESSUREor-/MAX/MINto turn on/off alarm 2. When it is set to be on, after exit, alarm 2 willbedisplayontheLCD. Relative/absolute air pressure At normal display mode, press +/AIR PRESSUREto swtich bewtween relative air pressure and absolute air pressure Temperatureunit andselection Hold MODE 2 seconds, the flashes, press+/AIR PRESSUREor-/MAX/MIN to select or . Activating reception from the outdoor sensor The outdoor sensor will transmit a signal about twice a minute,which is automatically received by the base station. However,you may also manually activate reception of the signal.To do so,press and hold the CHANNEL button for three seconds until the channel flashes.Following successful reception the animation of the symbol will symbol disappear and the transmitted temperature and humidity will appear in the display. Sunrise/sunset/moonrise/moonset time:
After setting your country and city, the weather station will calculate the approximate Times for Sunrise/sunset/moonrise/moonset. That is approximate time, differences can also result from your local terrain and weather. PressSUN/MOON button to check number of hours of sunlight for current day, If you want to check other location or other date sunrise and sunset Press and hold SUN/MOON to set,the country will blink,press +/AIR PRESSUREor-/MAX/MINto adjust the setting item, Press SUN/MOON to confirm. Set the City,year,month,date in the same way Weather forecast icons:
Indoor humidity The confort icon can show 3 levels:
Troubleshooting The device contains delicate electronic components. Thus radio transmitting equipment in the immediate vicinity may interfere with the appliance. If the display shows interference, move such objects away from the weather station. Electrostatic discharges can lead to malfunctions. In cases of the appliance failing to work,remove the batteries for a short while and the replace them. Obstacles.e.g.concrete walls,may make the reception susceptible to interference.In this event change the location. The specified rang is the open area range,meaning there should be no obstructions between the outdoor sensor and the base .Visual contact between the outdoor sensor and base will often improve transmission. Cold(outdoor temperature below 0) may also negatively impact battery performance of the outdoor sensor, this wireless transmission. Another factor which may interfere which reception is drained or weak batteries in the outdoor sensor. Replace these with fresh batteries. If the weather station is not working properly, briefly remove and reinsert the batteries. Disposal Batteries: batteries are hazardous waste. All consumers are required by law to dispose of batteries properly at the designated collections points. Suitable containers are provided for the proper disposal of batteries in industries which use batteries and at community collection points. Weather station clock: If you wish to dispose of your weather station clock or adaptor, you must comply with the applicable regulations. Products that are designated with the symbol below must not be disposed of as normal household waste. Details are provided by your local council. Packaging: the packing of the weather station clock must be disposed of according to the applicable regulations. Details are provided by your local council. Federal Communications Commission (FCC) Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications made to this device not expressly approved by Digi-Max Technology Limited may void the FCC authorization to operate this device. Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the users authority to operate the equipment.