Figure 1: iComLNC Control Panel The iComLNC Control Panel provides alarm communication using the on-board hardwired network connection with the option of using cell back-up over the Verizon LTE network. The iComLNC is used for multi-family applications and interfaces with Z-WaveTM sensor devices. It provides four hardwired zones and up to fifteen Z-Wave zones. The iComLNC also allows you to program Outputs in Output Options. The iComLNC is a stand-alone panel that is powered by a 12 V plug-in power supply. What is Included?
One iComLNC Control Panel One Model 388 Antenna One Model 372-500-W DC Plug-In Power Supply 1 INSTALL THE iComLNC When selecting a location to mount the panel, first mount the panel to a surface and then route all wires and connectors to it. Be sure to mount the panel within 100 feet of a wall outlet using 18-22 AWG wire. Use the following steps to install the iComLNC:
1. Remove the housing cover and mount the iComLNC base to a surface using the included #6 screws. It is not necessary to remove the panel from the base when mounting it. 2. Connect the panel + DC terminal to the positive terminal on the power supply and connect the - DC terminal to the negative terminal on the power supply. Be sure to route all wires through the wire cut-out shown in Figure 2. 3. Plug the network cable in to the ETHERNET port. 4. Place the antenna onto the SMA connector and twist until secure. 5. Replace the housing cover onto the base. 6. Plug the power supply into a 120 VAC 60 Hz dedicated outlet not controlled by a switch. SMA Connector Ethernet Port _
+
Wiring Cut-out Figure 2: Housing Features 2 PROGRAM THE COMMUNICATION TYPE The iComLNC comes defaulted with Net as the primary and DHCP set to Yes and comes with the central station IP address already programmed. Reference the iComLNC Programming Sheet (LT-1783) for any other adjustments you would like to make. If using the iComLNC for cellular communication, use the Dealer AdminTM site (DMPDealerAdmin.com) or call DMP Customer Service at 866.266.2826 to activate the cellular communicator. iComLNC CONTROL PANELInstallation and Programming GuideDESCRIPTION Cellular Activation 1. Navigate to the Dealer Admin site (DMPDealerAdmin.com). 2. Click Customers in the right-side menu and select a customer. 3. Click Add System. 4. Enter a System Name. 5. Select iComLNC from the System Type drop-down menu. 6. Select either Cellular or EASYconnect + Cell Backup as the Connection Type. 7. Enter the SIM number found on the iComLNC label and click Get Status. 8. Enter the Account Number. 9. Select a Rate Plan for the iComLNC. 10. Click Activate Cellular Device. 3 4 PROGRAM Z-WAVE DEVICES Use the iComLNC Control Panel Programming Sheet (LT-1783) to program the module and then follow the directions below to program the Z-Wave devices into the module using a keypad. 1. At the keypad, press CMD until MENU? NO YES displays. 2. Select YES. 3. Enter a user code and press CMD. 4. Press CMD until ZWAVE SETUP displays and then press any select key or area. 5. Select ADD when ADD LIST REMOVE displays. 6. At PRESS BUTTON ON DEVICE TO ADD, press the button on the Z-Wave device. The keypad beeps once and displays DEVICE FOUND. After a few moments, the keypad beeps again and displays the type of device found and then displays ADD LIST REMOVE. 7. From here, ADD another Z-Wave device or press the back arrow until ZWAVE SETUP displays to save Z-Wave programming. TAMPER Z-WAVE DEVICES Once all Z-Wave devices have been added to the panel, they will need to be tampered to become active. Follow the directions below to tamper the Z-Wave devices and check each Z-Wave devices status. 1. Go to each Z-Wave device and tamper it according to the devices instructions. 2. Once all Z-Wave devices have been tampered, it could take up to five minutes for associations to take place. 3. After tampering the devices and associations have taken place, go to the keypad and access ZWAVE SETUP. 4. Select LIST then press CMD to advance through the list of Z-Wave devices and ensure each device displays an OKAY status. If there are devices that do not display an OKAY status, remove the device and return to PROGRAM Z-WAVE DEVICES to start the process over. 2 iComLNC Installation Guide FCC INFORMATION This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. 2. This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from all persons. It must not be located or operated in conjunction with any other antenna or transmitter. Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver i connected. Consult the dealer or an experienced radio/TV technician for help. Industry Canada Information This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the following two conditions:
1. 2. This device may not cause interference, and this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes:
1. 2. lappareil ne doit pas produire de brouillage, et lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health Canada Safety Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of 7.87 inches (20 cm) to maintain compliance with the General Population limits. Lexposition aux radiofrquences de ce systme a t value selon la norme RSS-102 et est juge conforme aux limites tablies par le Code de scurit 6 de Sant Canada. Le systme doit tre install une distance minimale de 7.87 pouces (20 cm) sparant lantenne dune personne prsente en conformit avec les limites permises dexposition du grand public. iComLNC Installation Guide 3 iComLNC CONTROL PANELSpecificationsOutput 12VDCHousing Material Flame Retardant ABSHousing Color WhiteHousing Dimensions 5.5W x 3.75H x 1DAccessoriesOne Model 388 AntennaOne Model 372-500-W DC Plug-In Power SupplyCertificationsCellular FCC Part 15: RI7ME910C1NV Industry Canada: 5131A-ME910C1NVZ-Wave FCC Part 15: CCKPC0190 IC: 5251A-PC0190Underwriters Laboratory (UL) Listed ANSI/UL 294 Access Control System Units ANSI/UL 636 Holdup Alarm Units and System Accessory ANSI/UL 1023 Household Burglar ANSI/UL 1076 Proprietary Burglar ANSI/UL 1610 Central Station Burglar ANSI/UL 1635 Digital Burglar ANSI/UL 985 Household Fire Warning ANSI/UL 864 Fire Protective Signaling 9th Edition. ANSI/UL 365 Police Sta. Connected Burg Alarm Units & Systems ANSI/UL 609 Local Burg Alarm Units & SystemsLT-1784 18181