1 PROGRAM THE PANEL When programming the 1122 in the panel, refer to the panel programming guide as needed. In ZONE INFORMATION, enter the wireless ZONE number. 1. 2. Enter the ZONE NAME. 3. Select NT (Night) as the ZONE TYPE. 4. Select the AREA. 5. At the NEXT ZONE prompt, select NO. 6. Select YES when WIRELESS? displays. 7. Enter the eight-digit SERIAL# and press CMD. 8. Enter the SUPRVSN TIME and press CMD. 9. Choose whether or not to enable DISARM DISABLE. Note: Selecting YES allows the 1122 to be disabled for Night and Exit type zones while the area is disarmed. The 1122 Wireless PIR Motion Detector uses passive infrared technology to detect motion in a wide angle lens pattern. The 1122 also features an internal case tamper, survey LED, and low battery indicator. Pet immunity is available for animals up to 55 pounds and can be turned on or off. Disarm/disable, pulse count, and adjustable sensitivy are also offered on the 1122. Compatibility All DMP 1100 Series Wireless Receivers and burglary panels. What is Included?
One 1122 Wireless PIR Motion Detector One 3V lithium CR123A battery 10. Choose either 2 or 4 for the PULSE COUNT. Note: The pulse count is the number of pulse inputs
(trips) the 1122 needs to sense before going into alarm. 11. Choose either LOW or HIGH for the SENSITIVITY. Note: Selecting LOW sensitivity may reduce false alarms for installations in harsh environments. 12. Choose whether or not to enable PET IMMUNITY. 13. At the NEXT ZONE prompt, select YES if you are finished programming the zone. Select NO if you would like to access additional programming options. 2 INSTALL THE BATTERY Use only a 3.0V lithium battery, DMP Model CR123A, or the equivalent battery from a local retail outlet. Keep in mind, when setting up a wireless system, program zones and connect the receiver before installing batteries in the transmitters. 1. Remove the holding screw at the lower end of the 1122 case and gently lift off the cover. 2. Observing polarity, place the battery in the holder and press into place. See Figure 2 for the battery location. Battery Location Survey LED Tamper Switch PCB Screw Figure 2: 1122 Housing and PCB LT-1647 2017 Digital Monitoring Products, Inc.17164DESCRIPTIONFigure 1: 1122 Wireless PIR Motion Detector1122 WIRELESS PIR MOTION DETECTORInstallation Guide 3 SELECT A LOCATION The 1122 provides a survey capability to allow one person to confirm communication with the wireless receiver or panel while the cover is removed. This allows you to easily determine the best location for the 1122. Location Dos Do locate on a rigid vibration-free surface Do locate so that the expected intruder's movement will be across the detection pattern Do locate between 4.9 and 8.2 feet high. Location Don'ts Don't locate on a surface exposed to moisture Don't locate on any area containing excessive metallic surfaces Don't locate with direct sunlight, heat sources (heaters, radiators, etc.), or strong air drafts (fans, air conditioner, etc.) in the field of view Check the Location Using the Survey LED 1. Hold the 1122 in the exact desired location. 2. Press the tamper switch to send data to the receiver and determine if communication is confirmed or faulty. See Figure 2 for tamper switch and LED locations. Confirmed: If communication is confirmed, the survey LED turns on when data is sent to the receiver and off when acknowledgement is received. Faulty: If communication is faulty, the LED remains on for about 8 seconds or flashes multiple times in quick succession. 3. Relocate the 1122 or receiver until the LED confirms clear communication. Proper communication between the 1122 and receiver is verified when for each press or release of the tamper switch, the LED blinks immediately on and immediately off. 4 TEST COMMUNICATION TO THE PANEL Walk Test Before performing the following tests, ensure the 1122 is programmed in the panel. 1. At the keypad, enter 8144 (WALK) and select WLS. 2. The LED will flash three times indicating it is in Walk Test mode. This activates the device for two minutes in Walk Test mode. 3. Walk test the unit to verify the PIR coverage. At the end of the Walk Test mode, the LED will flash six times. Note: This is for IR detection only and does not send an RF transmission. Tamper Transmission Test 1. Remove the holding screw at the lower end of the 1122 case and gently lift off the cover to fault the tamper and initiate a tamper trouble message. 2. Verify that the keypad display indicates a tamper message. 3. Place the cover back onto the 1122 and tighten the holding screw back into place. 2 DIGITAL MONITORING PRODUCTS | 1122 INSTALLATION GUIDE 5 MOUNT THE 1122 Prior to permanently mounting the 1122, check that it is properly communicating with the panel. See the Select a Location and Test Communication to the Panel sections. 1. Remove the holding screw at the lower end of the 1122 case and gently lift off the cover. 2. Loosen the screw located on PCB and slide the PCB out of the unit. 3. Place the 1122 against the wall and screw through the appropriate mounting holes. Flat Wall: For flat wall installations, choose from the mounting hole locations shown in Figure 3. Be sure to insert a screw in the tamper mounting hole. Corner: For corner installations, choose from the mounting hole locations shown in Figure 4. Be sure to insert screws in the tamper mounting holes. 4. Reinstall the PCB back into the unit. Tighten the PCB screw to secure it into place. 5. Place the cover back onto the 1122 and tighten the holding screw back into place. REPLACE THE BATTERY 1. Remove the holding screw at the lower end of the 1122 case and gently lift off the cover. 2. Remove the old battery and dispose of it properly. See Figure 2 for the battery location. 3. Observing polarity, place the new battery in the holder and press into place. Note: Use only 3V Lithium CR123 batteries. 4. Place the cover back onto the 1122 and tighten the holding screw back into place. Caution: Properly dispose of used batteries. Do not recharge, disassemble, heat above 212F (100C), or incinerate. Risk of fire, explosion, and burns. Sensor Reset to Clear LOBAT When the battery needs to be replaced, a LOBAT message will display on the keypad. Once the battery is replaced, a sensor reset is required at the system keypad to clear the LOBAT message. 1. On a Thinline keypad, press and hold 2 for two seconds. On a touchscreen keypad press RESET. 2. Enter your user code if required. 3. The keypad displays SENSORS OFF followed by SENSORS ON. MOUNTING HOLES Tamper Mounting Hole Figure 3: Flat Mounting Hole Locations Tamper Mounting Holes Figure 4: Corner Mounting Hole Locations 1122 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS 3 FCC INFORMATION This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. 2. This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from all persons. It must not be located or operated in conjunction with any other antenna or transmitter. Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Industry Canada Information This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the following two conditions:
1. 2. This device may not cause interference, and this device must accept any interference, including interference that may cause undesired operation of the device. Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes:
1. 2. lappareil ne doit pas produire de brouillage, et lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health Canada Safety Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of 7.87 inches (20 cm) to maintain compliance with the General Population limits. Lexposition aux radiofrquences de ce systme a t value selon la norme RSS-102 et est juge conforme aux limites tablies par le Code de scurit 6 de Sant Canada. Le systme doit tre install une distance minimale de 7.87 pouces (20 cm) sparant lantenne dune personne prsente en conformit avec les limites permises dexposition du grand public. Designed, engineered, and manufactured in Springfield, MissouriINTRUSION FIRE ACCESS NETWORKS2500 North Partnership BoulevardSpringfield, Missouri 65803-8877800-641-4282 | dmp.comSpecificationsBattery Life Expectancy 3 Years (normal operation) Type 3.0V Lithium CR123AFrequency Range 905-924 MHzDetection Range 900 40 x 40 feet Speed 1 to 5 feet/secondMounting Height 4.9 to 8.2 feetTransmit Condition Alarm, Low Battery Specifications, cont.Color WhiteHousing Material Flame retardant ABSDimensions 5" Length x 2.6" Width x 1.5" DepthCertifications FCC Part 15 Registration ID CCK1122 Industry Canada Registration ID 5251A-1122Patents U.S. Patent No. 7,239,2361122 WIRELESS PIR MOTION DETECTOR