dormakaba Face Recognition Terminal 91 60-K5 User Manual EN User Manual Table of Contents 1 Product Description ..............................................................................................................................01 1.1 Overview................................................................................................................................01 1.2 Technical Data.......................................................................................................................02 1.2.1 System.........................................................................................................................................02 1.2.2 Operating Mode..........................................................................................................................02 1.2.3 RFID Read...................................................................................................................................02 1.2.4 Power Supply...............................................................................................................................02 1.2.5 Inputs/Outputs..............................................................................................................................02 1.2.6 Ambient Condtions.......................................................................................................................02 1.2.7 Dimensions...................................................................................................................................03 1.3 Featrue structure....................................................................................................................07 1.3 Labeling..................................................................................................................................08 Installation................................................................................................................................................09 2 2.1 Installation lines......................................................................................................................09 2.1.1 Power Supply lines.......................................................................................................................09 2.1.2 Data lines......................................................................................................................................09 2.1.3 Connections...................................................................................................................................09 3 Start-up and commissioning...................................................................................................................11 3.1 Start-up...................................................................................................................................11 3.2 System activation adn login...................................................................................................12 3.2.1 System activation and Initialize.....................................................................................................12 3.3 Device Local Management......................................................................................................17 3.3.1 Personner management.................................................................................................................14 3.3.2 Logbook.........................................................................................................................................19 3.3.3 Face Control...................................................................................................................................20 3.3.4 Parameter Settings.........................................................................................................................21 3.3.4.1 Customer paremeters..............................................................................................................22 3.3.4.2 Communication setting.............................................................................................................24 3.3.4.3 Universal parameters................................................................................................................26 3.3.5 Peripherals ....................................................................................................................................27 3.3.6 About..............................................................................................................................................28 3.3.6.1 Basic Device Information..........................................................................................................28 3.3.6.2 Modify activation......................................................................................................................28 3.3.6.3 APP Version Update................................................................................................................29 3.3.6.4 Firmware Upgrade...................................................................................................................29 3.3.6.5 Restore factory........................................................................................................................30 3.3.6.6 Restore Default.......................................................................................................................31 4 Troubleshooting.......................................................................................................................................32 dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 Product Description 1 Product description 1.2 Overview User Manual Modern finish design ,8-inch LCD Touch screen . High-speed processing and a large storage capacity m ake the term inal a powerful range: 1:30,000 user identification is carried out in 1 second. Technology & Function:
The dorm akaba 91 60-K5 Face Recognition Term inal can be easily integrated into building structures. It has large screen ratio which supports 1:N or 1:1 face authentication . The devices em bed a web server enabling on-device enrollm ent, term inal configuration and transaction log retrieval. For scenarios requiring the use of contactless cards, the series also features m ultiple card reader or QR code reader dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 1 User Manual Technical Data 1.2 1.2.1 System linux: gcc-arm -8.3-2019.03-x86_64-arm -linux-gnueabihf 1.2.2 Operating mode Connect Discern Software for online or standalone. 1.2.3 RFID/Temperature Measurement RFID Reader Only(Legic&Mifare) RFID Reader with QR Code (Legic&Mifare) QR Code Only. Infrared Im aging Tem perature Measurem ent Set 1.2.4 Power supply Rated voltage: 12V DC 1.8A 1.2.5 Inputs/outputs
Network* 1
USB* 1
Tam per* 1
Wiegand* 1
Realy output* 1 Input Single* 2 1.2.6 Ambient conditions
Operating tem perature: -20 ~ + 70
Relative hum idity: 10% - 90% (non-condensing)
Waterproof level: IP66 dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 2 User Manual 1.2.7 Dimensions
237m m L x 133m m W x20.8m m H All dimensions in mm. Wall dimension drawing dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 3 User Manual Mounting dimensions of bracket without temperature measurement dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 4 User Manual Dimension drawing of module with temperature measurement dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 5 User Manual Mounting dimensions of bracket with temperature measurement dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 6 User Manual 1.4 Featrue structure Infrared fill light RGB Camera Infrared Camera Card reading area Bottom fixing screw Bottom fixing screw Indicator feedback signal wiring Infrared sensor module Backplane fixing screw 8 Inch Touch Screen Temperature measurement module dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 7 User Manual 1.4 Labeling The identification plate is located on the underside of the device. The identification plate contains:
Device name Item number Serial number Connection data (power supply) dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 8 User Manual 2 Installation Installation Lines 2.1 2.1.2 Power Supply Cable Power is norm ally supplied to the 9160 term inal by the seperate power supply. Recom m ended cable: RVVP 2* 1.0 or higher. In case of long lines, the voltage drop due to line resistance will need to be considered. 2.1.2 Data lines Data transm ission is m ainly network data transm ission. Recom m ended cable: CAT.5 or higher. 2.1.3 Connections The following connections should be present at the installation location:
Ethernet cable, with RJ45 plug
Power supply cable
Lines to electric strikes and opener key.
Lines to the Wiegand Interface dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 9 User Manual 12V DC 1.8A
(not use) GPIO The combination of NO and COM is normally open,while that of NC and COM is normally closed.The main equipment needs to use our power supply for independent power supply. dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 10 User Manual 3 Start-up and commissioning 3.1 Start-up Start-up and communication in regular operation are done via an Ethernet network. Power Suppply: DC12V 1.8A The firewall configuration m ust therefore be adapted accordingly. Without temperature measurement Step 1 Step 2 Step 3 With temperature Step 1 Step 2 Step 3 dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 11 User Manual 3.2 System Activation and login System-specific settings, connection settings, such as assignment of a fixed IP address, can be made via the 91 60 system settings. Activate the 91 60 system settings 1.Start the terminal. 2.If the 9160 is started for the first time, the system prompts you to activate it. 3.After the startup is complete, the main activation screen is displayed. Step 1:The first login screen will prompt you to set the language to be used dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 12 User Manual Step 2:Set the account and password, enter the account password you need to set dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 13 User Manual Step 3:Set up network configuration dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 14 User Manual Step 4: User modedefault is Access mode. Attendance mode is currently disabled. Management mode Server mode is to use software to configure the device(for example DISCERN) Standalon mode is the local configuration device Server IP and account is the configured server connection address and account information dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 16 User Manual 3.3 Device Local Management Local Settings contain device parameters and some local configuration. 1.Personnel management 2.Logbook 3.Face Control 4.Parameter Setting 5.Peripherals 6.About Login the 91 60:
In the upper right corner of the 91 60 screen, hold down the screen. The login screen is displayed. Enter your account and password to enter the main screen Login interface Menu options dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 17 User Manual 3.3.1 Personnel management The personnel management mainly consists of the locally add personnel photo , the local badge number and the output of Weigen number 1.The action menu is displayed after successful login and select the Personnel management Click this button 1.Click the button to add the person 2.Input the information to add Click here to take photo 3. Take photo dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 18 User Manual 3.3.2 Logbook Logbook mainly display local access log and system log and exception log 1.The action menu is displayed after successful login and select the Logbook Filter conditions Log type 1.Enter the employee ID or name to filter logs 2.View Select a log type 3. Event description and time dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 19 User Manual 3.3.3 Face Control Face Control is includes Face algorithm and access control interface Settings 1.The action menu is displayed after successful login and select the Face Control Algorithm Parameters:
Enable the mask detection function. Enable face recognition in Live detection Set the threshold of face recognition, the size of the value of the eigenvalue adjustment Set the size value of the face recognition 1.Algorithm settings Interface Parameter Configure wiegand output function and format, Wiegand 26/32/34 output format Configure the format of the card number identified by 91 60 Configure the 485 interface and baud rate. Currently, the functions are disabled The Bluetooth function is enabled 2. Interface Parameter dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 20 User Manual Interface Parameter Relay Control Set the face recognition mode, QR Code function is not available at present Set the door open too long time, this parameter takes effect when the door sensor enable Set the door open time. Set the recognition success delay relay output 2. Interface Parameter Input 1: Set the door sensor fuction is enable. Input 2 function is not available at present Input 3 function is not available at present 3.3.4 Parameter Setting Parameter Settings include Customer setting and Communicationsetting and Universal setting The action menu is displayed after successful login and select the Parameter Settings 3.3.4.1 Customer Parameters 3.3.4.2 Communication Settings 3.3.4.3 Universal Settings dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 21 User Manual 3.3.4.1 Customer Parameters Customer Parameters include Basic settings and Display Settings 1.The action menu is displayed after successful login and select the Parameter Settings--
Customer Parameters Basic Settings:
Device Name Description Company Name Description Description of the device installation position 1.Basic settings Dispaly Prompt settings Enable the function to display the name of the person after the successful face verification Select whether to display photos after face verification or enable the temperature measurement function to display thermal imaging thumbnail images Enable voice prompt for face verification The text message displayed on the screen when the face is verified for success and failure Whether to enable low-power mode, 91 60 disable some functions in idle state , such as NFC/Infrared light of the device. 2. Dispaly settings dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 22 User Manual Dispaly Prompt settings Whether to enable the registration of photos with similar faces Set whether to display stranger face verification logs on the logbook Whether to enable the local storage of registered photos on the 91 60 Whether to enable the device to locally save the verified face photos Specifies the maximum number of days for locally stored logs Maximum number of records in the local storage Device Parameters Sound volume Settings for the device Adjust the brightness of the device Set the standby time of the device The interval between recognition 2.Display settings 3.Device Parameters dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 23 User Manual 3.3.4.2 Communication Setting Communication Settings mainly include IP address and communication interface server address Settings 1.The action menu is displayed after successful login and select the Parameter Settings--
Commnication setting Ethernet Settings:
Set the IP address of the device and enable the DHCP function 1.Ethernet Settings Host Configuration:
Set the address, port, account and password of the communication server (such as DISCERN or third-party interface software). 2. Host Configuration dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 24 User Manual 3.3.4.2 Communication Setting Communication Settings mainly include IP address and communication interface server address Settings 1.The action menu is displayed after successful login and select the Parameter Settings--
Commnication setting Ethernet Settings:
Set the IP address of the device and enable the DHCP function 1.Ethernet Settings dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 25 User Manual 3.3.4.3 Universal Parameters Universal Parameters include the local language, NTP server Settings 1.The action menu is displayed after successful login and select the Parameter Settings--
Universal Parameters Languages and Data/time settings:
Language Settings. Currently, only Chinese and English are supported 1.Languages and Data/Time settings Set the time synchronization server dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 26 User Manual 3.3.5 Peripherals Peripherals mainly include how to enable and configure the temperature measurement function. 1.The action menu is displayed after successful login and select the Peripherals--
Temperature Parameters Algorithm Parameters:
Enable the temperature alarm function only when the temperature measurement function is enabled Set the value of alarm temperature Set the identification distance of temperature measurement 1.Algorithm Parameters Thermal sensor settings:
Enable the temperature measurement function In general, the verification function is not required. The boldbody verification function is used only in the case of inaccurate temperature measurement Warning:The black body caliration procedure is only for professionals to operate. Wrong operation will cause inaccurate body temperature measurement. In general, the Double lighe is not required. The Double lighe verification function is used only in the case of inaccurate temperature measurement Warning:The double light caliration procedure is only for professionals to operate. Wrong operation will cause inaccurate body temperature measurement. 2. Thermal sensor settings dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 27 User Manual 3.3.6 About About mainly include About includes basic device information (model, serial number, and MAC address), APP update, and firmware upgrade. 3.3.6.1 Basic Device Information Basin Device Information includes: Device model, serial number, MAC address, device version, and activation code information. 1.The action menu is displayed after successful login and select the About. Basic Device Information:
Display device model and serial number Displays the MAC addresses of network adapters and wireless network adapters Display APP version, face algorithm version and firmware version number Device activation code. NOTE:You must keep the device connected to the network when activating the device 3.3.6.2 Modify activation Use activated device purpose 1.The action menu is displayed after successful login and select the About--Modify activation The device is delivered with an activation code. If the device does have an activation code, you need to contact the manufacturer to obtain the activation code and enter the activation code to activate the device while keeping the device connected to the Internet dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 28 User Manual 3.3.6.3 Update Update the 91 60 APP version 1.The action menu is displayed after successful login and select the About-Update Update:
Steps to update your APP 1.Copy the attachment "xxxxx.tar.gz" to the root directory of U disk 2.Rename xxxxx.tar.gz to update_app.tar.gz on your USB drive 3.Insert the U disk into the USB interface of the 9160 4.Keep touching the upper right corner of 9160 to display the login interface (Enter the account and password for initializing the device for the first time) 5. About--Update Note:You can update APP versions with interfaces (e.g. DISCERN and third-party interface software) 1.Update 3.3.6.4 Firmware Upgrade Upgrade the 91 60 firmware version 1.The action menu is displayed after successful login and select the About-Firmware Upgrade dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 29 User Manual Firmware Upgrade:
Steps to update your firmware 1.Copy the attachment "xxxxx.img" to the root directory of U disk 2.Rename xxxxx.img to update.img on your USB drive 3.Insert the U disk into the USB interface of the 9160 4.Keep touching the upper right corner of 9160 to display the login interface (Enter the account and password for initializing the device for the first time) 5. About--Firmware Upgrade Note:After the firmware is updated, the device needs to be reactivated. Please back up the activation code of the device 1. Firmware Upgrade 3.3.6.4 Restore the factory Restore factory Settings will clear the local Settings and account information 1.The action menu is displayed after successful login and select the About-Restore factory Restore factory:
Restore factory Settings will clear all data of the 91 60, and you need to initialize the device to set the account and password of the 91 60. 1. Restore the factory dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 30 User Manual 3.3.6.5 Restore default Restore Default will Clear user Settings and restore the device to factory default Settings. 1.The action menu is displayed after successful login and select the About-Restore default. Restore default:
Restore Default Settings Clear user Settings and restore the device to factory default Settings. 1.Restore default dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 31 User Manual 4 Troubleshooting Troubleshooting:
Trouble List No Response when Power Up Solution Discount the power and confirm that the power supply cable is correctly connected (See Wiring above). Check the input voltage is sufficient (See Specifications above). Auto Restart Check the input voltage is sufficient (See Specifications above). Check the format setting on the controller if it is the same as the card format. Cannot read card Use approved card (known format and Facility Code) to test. number correctly Check if the shield cable is correctly connected to Classis Ground at ONE point only. Reader beeps but No card data info Check if data 0 & data 1 cable is correctly connected (See Wiring above). Check the input voltage at the card reader end is correct (See Specifications above). dorm akaba 91 60-K5 Face Recognition Term inal 09/2021 32 FCCStatement Any Changesormodifications not expresslyapprovedbythepartyresponsibleforcompliance couldvoidtheusersauthoritytooperatetheequipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)Thisdevicemaynotcauseharmfulinterference,and
(2) This device must accept any interference received, including interference that may cause undesiredoperation. RFwarningforPortabledevice:
ThedevicehasbeenevaluatedtomeetgeneralRFexposurerequirment.Thedevicecanbeused inportableexposureconditionwithoutrestriction. Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device,pursuant to part 15 of the FCCRules.Theselimitsare designedtoprovidereasonable protection against harmful installation. This equipment generates,uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthis equipment does cause harmful interference to radio or television reception, which can be determinedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrectthe interferencebyoneormoreofthefollowingmeasures:
Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiveris connected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. in a residential interference