EN Terminal 96 00 Quick Guide Model No:9600-K6 BLE FCC ID:NVI-KT9600K6B IC:11038A-KT9600K6B About this quick guide Validity This quick guide describes the product Assembly and installation The product should only be installed in locations which fulfil the en-
vironmental and technical conditions specified by the manufac-
turer. The manufacturer is not liable for damage arising due to improper handling or incorrect installation. Environmental protection It is prohibited to dispose of the device in your domestic waste. Used devices contain valuable materials that should be recycled. Properly dispose of used devices. Product description The terminal 96 00 can be used for time and attendance and as CardLink update terminal. Depending on the focus of application, B-Client AC15, B-Client HR15 or B-Client HR20 terminal software is available. The operat-
ing system used of the terminal 96 00 is 'Android. To display information, the terminal has a graphic 4" TFT colour display with a resolution of 480 x 800 pixels. A capacitive input field extends over the display surface and is operated by touching the glass front. The person-related data is recorded by a contactless RFID reader. In addition, there is the possibility of booking with a smartphone. The communication with the superior system takes place via Ether-
net. Alternatively and optionally, communication can also take place via radio network or WLAN. The terminal is supplied with Power over Ethernet (PoE). Product designation:
Terminal 96 00 Product ID:
Item number:
9600-K6 04079601 Date of manufacture:
From September 2019 Target group This quick guide should only be used by skilled persons trained by the manufacturer. Additional documentation The content of this quick guide is an excerpt from the technical manual and is limited to essential information about the product and how to install it. Details on functions, commissioning and parameter setting of the product can be found in the following documentation:
Technical data System Operating system Terminal 96 00 - Technical Manual B-Client HR20/HR15/AC15 - reference manual Service interface - reference manual Additional documentation is available on the Internet at the dormakaba website. The technical manuals are located in a protec-
ted area. They can be accessed via the user account of trained pro-
fessionals. However, you can also create a temporary account. https://www.dormakaba.com/extranet-emea-en Safety instructions Designated use The product is only intended for use as described in chapter
"Product description". Any use beyond that is considered contrary to its designated use. The manufacturer cannot be held liable for damage resulting from such use. Staff qualification The actions described in this quick start guide must only be carried out by skilled persons in accordance with EN 62368-1. Skilled person is the designation for people who have the appropri-
ate technical training and experience in setting up the equipment. Skilled persons are expected to use their training and experience to identify any risks to themselves and others that may arise while carrying out these activities, and to minimise these risks as far as possible. It is the skilled persons responsibility to ensure that the conditions stated by the manufacturer and the applicable regula-
tions and standards are complied with when carrying out these ac-
tions. Android version 5.0.2 (Lollipop) Freescale i.MX6DualLite processor CPU Memory 2 GByte DDR3 RAM 8 GByte eMMC Flash Parameters and data records are retained without supply voltage. Real-time clock The device has an integrated real-time clock. The function of the RTC is ensured for about 2 months without power supply of the device. Display TFT LCD display module Size: 4.0"
Resolution: 480 x 800 pixels (16:9 diagonal) Colour depth: 24-bit (true colour) Luminance: 350 cd/m Backlit with 8 LEDs 4 PCAP touch screen over the complete display Touch screen Audio Integrated loudspeaker (1 W) Interfaces/Communication Ethernet interface IEEE802.3 compatible10BASE-T/100BASE-TX /1000BASE-T Auto sensing, Auto MDIX 04044303 - 06//2019 - DRAFT 1/4 Quick Guide WLAN (optional) According to IEEE802.11 a/b/g/n (2.4 GHz + 5 GHz) Encryption: WPA2-PSK Mobile radio (option) UMTS 900/2100 MHz (dual band) GSM 850/900/1800/1900 MHz (dual band) Power supply PoE (Power over Ethernet) Power supply of the terminal via the 8-wire Ethernet cable (max. 100 m) According to IEEE802.3at PD type 1 Performance class 0 (0.44-12.95 W) Supported feed processes: Spare pair feed and phantom feed Reader Depending on the version, the terminal supports the following RFID readers:
MRD - LEGIC prime/advant, MIFARE Classic/DESFire Bluetooth Low Energy (Android Smartphone + iPhone) HID - iCLASS SE, iCLASS, Prox Booking via Smartphone (optional) The following technologies are supported:
NFC (Android Smartphone) Ambient conditions Ingress protection according to IEC 60529 IP20 IP65 (with optional cable sealing) Relative humidity 5% - 85%, non-condensing Ambient temperature
-25 C +55 C (operation)
-25 C +70 C (storage) Width: 89 mm, height: 177 mm, depth: 32 mm Dimensions Conformity This product complies with the standards EN IEC 62368-1:2020+A11:2020 ETSI EN 301 489-1 V 2.2.3 ETSI EN 301 489-3 V2.1.1 ETSI EN 300 330 V2.1.1 ETSI EN 300328 V2.2.2 EN 62311: 2020 according to the provisions of the EU directives 2014/35/EU - Low Voltage Directive (LVD) 2014/30/EU - Electromagnetic Compatibility Directive (EMC) 2014/53/EU - Radio Equipment Directive (RED) RoHS This device complies with the regulations of Directive 2011/65/EU. You can download the original declaration of conformity in PDF format at www.dormakaba.com/conformity. In addition, the product also complies with the following standards UL62368-1:2014 CAN/CSA-22.2 No. 62368-1:2014 FCC Code of Federal Regulations, FCC Part 15 Class C 2/4 Terminal 96 00 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference. This device must accept any interference received, including in-
terference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to oper-
ate the equipment. Model Name: 9600-K6 MRD FCC ID: NVI-KT9600K6L IC: 11038A-KT9600K6L Model Name: 9600-K6 MRD 3G FCC ID: NVI-KT9600K6L3G IC: 11038A-KT9600K6L3G Model Name: 9600-K6 MRD WiFi FCC ID: NVI-KT9600K6LWL IC: 11038A-KT9600K6LWL Model Name: 9600-K6-HID FCC ID: NVI-KT9600K6H IC: 11038A-KT9600K6H Model Name: 9600-K6-HID 3G FCC ID: NVI-KT9600K6H3G IC: 11038A-KT9600K6H3G Model Name: 9600-K6-HID WiFi FCC ID: NVI-KT9600K6HWL IC: 11038A-KT9600K6HWL Device structure The product consists of the terminal housing (1) and the mounting plate (2). The mounting plate (2) is the wall-mounting element of the device. The terminal (1) is hung into the mounting plate (2) and secured with two screws (4) from below. The network cable is led to the terminal from the rear. The network connection is located on the rear of the terminal. The product has a magnetic sabotage contact (3). The terminal software uses it to detect when the housing is removed from the mounting plate and generates an alarm record. Installation Mounting height Recommended mounting height 140 cm to the top edge of the ter-
minal. The mounted height for the terminal should not be higher than 2 meters. 04044303 - 06//2019 - DRAFT Terminal 96 00 Quick Guide Fastening the mounting plate The mounting plate can be installed directly on the wall or on a double switch box according to DIN 49073-1. The mounting plate has 4 fastening holes for each of the two fastening variants. For direct fastening of the mounting plate to the wall, 4 dowels SX6 and 4 suitable screws are included in the delivery. For fastening the mounting plate to a switch box, 4 countersunk screws are included in the delivery. When mounting on different surfaces, use suitable fastening ma-
terial. If you use other fastening screws, make sure that the flat head of the screw disappears completely in the perforation in the mounting plate. 1 2 Scope of delivery 1x sealing cap 1x seal with cable passage 5.7 mm 1x seal with cable passage 8.2 mm 1x self-adhesive foam strip 1.0 mm thick 1x self-adhesive foam strip 2.0 mm thick 6x fillister head self-tapping screw 1x TORX screw wrenchT6 Principle The sealing cap is fastened to the rear of the terminal via the net-
work connection. Depending on the diameter of the network cable, additional measures for sealing the cable entry are required. Use seal with corresponding cable passage. Attach a semicircular foam strip to the cable entry of the ter-
minal housing. 3 Wrap foam strip around the network cable using full circles in the area of the cable entry. Cable 1 2 4.5 mm - 5.5 mm 5.7 mm 1 mm 2 mm 5.6 mm - 6.0 mm 5.7 mm -
6.1 mm - 7.0 mm 8.2 mm -
2 mm 7.1 mm - 7.5 mm 8.2 mm -
7.6 mm - 8.5 mm 8.2 mm -
1 mm 3
Procedure 1. If required, attach foam strip (see table). 2. Connect the network cable. The mounting plate may not be mounted twisted. The screws may only be tightened slightly. The mounting plate may not be de-
formed or bent. In case of soft mounting surfaces, make sure that the housing is not pressed into the surface when mounting it. The unevenness of the mounting surface may not exceed 0.5 mm. The unevenness of the mounting surface may have to be compensated for or adjusted by means of suitable measures (e.g. washers). Connecting the network cable The Ethernet connection (RJ45 socket) is located on the rear of the terminal housing. 3. Insert the seal with suitable cable passage (see table) into the sealing cap. Fastening the sealing cap The increased ingress protection according to IEC 60529 specified in the technical data is only reached when using this additional cable cover. The sealing cap for cable sealing is an optional accessory of the ter-
minal 96 00. 04044303 - 06//2019 - DRAFT 3/4 Quick Guide screws. 4. Fasten the sealing cap above the connection area using 6 Automatic registration via B-COMM Fastening the terminal to the mounting plate 1. Hang terminal into the mounting plate at the top and press against it at the bottom. 2. Secure terminal housing on the mounting plate using 2 screws ers. M3x6. Terminal 96 00 Start-up of the terminal takes place largely automatically in con-
nection with the communication software B-COMM. The device is preset at the factory for automatic registration via B-COMM. For communication via WLAN, the connection must have been previously set up and activated. This is done via the system settings. System requirements B-COMM communication software version 3.17.1 and higher. Network with a working DHCP server. Start-up procedure 1. Connect the power supply for the device. After booting, the device cyclically reports to the B-
COMMs active in the network. At this point, until start-up by a B-COMM is complete, the message Waiting for registra-
tion is displayed on the display. Once the device is detected by B-COMM, the relevant data that identifies the device will be queried. If the device is not known, it will be entered in B-COMM under the B-COMM Terminal Discovery client under BCTDS
(Terminal Discovery Stream). 2. Add device in B-COMM to the desired communication channel. 3. Provide device with the appropriate communication paramet-
After having assigned the device permanently to B-
COMM, B-COMM first updates the settings of the device and then makes a backup of the settings together with the 'sop.ini licence file. The device now reports to the B-COMMs active in the net-
work that registration has been carried out, after which the device will be removed again from the BCTDS stream by the other B-COMMS. 4. Load specific parameters and master records to the device. The terminal software is restarted automatically. After that, the device is ready-to-operate. Devices with MRD reader (multi-reader device) Devices with MRD reader support LEGIC or MIFARE media, de-
pending on the reader type set. For LEGIC media, the LEGIC reader type has been factory-preset. For processing MIFARE media, the reader type must be changed to MIFARE. The reader type can be adjusted in the following ways:
Locally on the device via the test program or service interface Remote via the service interface Via the B-COMM communication software Commissioning Network requirements The network must have been equipped with a working DHCP server. It must be possible to transfer UDP data packages unhindered to the B-COMM server. IP address 239.255.255.250, UDP port 1900 dec. and UDP port 7900 (30976dec.) must have been enabled. The SSDP service has to be enabled in the Windows service management. The SFTP connection via the standard port 22 must have been enabled. CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. RF exposure information: The Maximum Permissible Exposure (MPE) level has been calculated based on a distance of d=20 cm between the device and the human body. To maintain compliance with RF exposure requirement, use product that maintain a 20cm distance between the device and human body. Operating Frequency Range:BT:2402~2480MHz; RFID:13.56MHz;
Max EIRP: BT:3.52dBm;
dormakaba EAD GmbH | Albertistrae 3 | 78056 Villingen-Schwenningen | Germany T: +49 7720 603-0 | www.dormakaba.com | Company headquarters: Villingen-Schwenningen 04044303 - 06//2019 - DRAFT 4/4 Federal Communication Commission (FCC) Radiation Exposure Statement When using the product, maintain a distance of 20cm from the body to ensure compliance with RF exposure requirements. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause FCC statements:
undesired operation. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the users authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. IC Notice:
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada. This device complies with Canada Industry licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference. and (2) this device must accept any interference. Including interference that may cause undesired operation of the device. CAN ICES-3 (B) Le prsent appareil est conforme aux CNR dIndustrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorise aux deux conditions suivantes :
(1) lappareil ne doit pas produire de brouillage; (2) lutilisateur de lappareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est susceptible den compromettre le fonctionnement. When using the product, maintain a distance of 20cm from the body to ensure compliance with RF exposure requirements. Lors de l'utilisation du produit, maintenez une distance de 20 cm du corps afin de vous conformer aux exigences en matire NMB-3 (B) d'exposition RF.