Terminal 97 00 Technical Manual 04043552 - 05/2017 DRAFT EN dormakaba EAD GmbH Albertistrae 3 78056 Villingen-Schwenningen Germany T: +49 7720 603-0 www.dormakaba.com Company headquarters: Heiligenhaus Copyright dormakaba 2017 All rights reserved. No part of this document may be reproduced or used in any form or by any means without prior written permis-
sion of dormakaba Schweiz AG. All names and logos of third-party products and services are the property of their respective owners. Subject to technical changes. 04043552 - 05/2017 DRAFT Technical Manual Table of Contents Table of Contents About this document Validity Target group Content and purpose Using the document Additional documentation 1 1.1 1.2 1.3 1.4 1.5 1.6 Warnings Hazard categories Symbols 1.6.1 1.6.2 Information Instructions 1.7 1.8 Basic safety information Proper use Assembly and installation Service and maintenance Accessories and spare parts Electrical hazards 2 2.1 2.2 2.3 2.4 2.5 2.6 Handling of lithium batteries 2.7 2.8 ESD protective measures Environmental protection Product description 3 3.1 Overview 3.2 Technical data 3.2.1 System 3.2.2 Multimedia 3.2.3 3.2.4 3.2.5 3.2.6 3.2.7 3.2.8 3.2.9 Dimensions Interfaces/Communication Reader Inputs/Outputs Power supply Uninterruptible power supply Ambient conditions 3.3 Conformity 3.4 Marking Construction and function 4 4.1 Device structure Basic equipment Terminal housing - Front Terminal housing - Rear side Docking station Interface assignment Uninterruptible power supply UPS510 4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 Product versions 4.2.1 4.2.2 Optional equipment (not retrofittable) 4.2.3 Optional equipment (retrofittable) 4.2.4 Accessories Terminal software 4.3.1 4.3.2 4.3.3 4.3.4 System connection 4.4.1 BaseApp Kaba test program B-Client HR30 terminal software B-Client HR30 software options Communication principle 4.2 4.3 4.4 7 7 7 7 8 8 9 9 9 9 10 11 11 11 11 11 12 12 13 13 14 14 15 15 15 16 16 16 17 17 17 18 21 22 23 23 24 25 26 30 30 31 31 31 31 31 32 32 32 32 32 35 35 04043552 - 05/2017 DRAFT Terminal 97 00 3 Table of Contents Technical Manual Parametrization Authorizations 4.4.2 4.4.3 4.4.4 Data from the terminal 4.4.5 Operating states 4.4.6 Devices with biometric reader 4.5 Authentication types 4.5.1 Mode 1: Identification 4.5.2 Mode 2: Verification 4.5.3 Mode 3: Verification (ID) 4.5.4 Mode 4: Combination of modes 1 and 2 4.5.5 Mode 5: Combination of modes 2 and 3 4.5.6 4.5.7 Alternative types of authentication Additional PIN entry 4.6 CardLink 5 5.1 5.2 General Installation site Connections Power supply Cable entry Installation Installation conditions 5.1.1 5.1.2 5.1.3 5.1.4 5.1.5 Installation lines 24 V DC power supply 5.2.1 5.2.2 Mains voltage supply 5.2.3 5.2.4 Fastening the docking station Ethernet Inputs/Outputs 5.3 5.4 Connections Connecting the network cable Connecting the mains voltage 5.4.1 5.4.2 5.4.3 Mains fuses 5.4.4 Connecting 24 V DC power supply 5.4.5 Digital inputs Relay outputs 5.4.6 5.4.7 Connecting an external reader 5.5 Uninterruptible power supply UPS510 5.6 Fasten the terminal housing to the docking station. Commissioning 6 6.1 Network requirements Communication Comparing finger templates Automatic registration via B-COMM 6.1.1 6.1.2 6.1.3 Automatic registration via B-COMM 6.2.1 Cancelling automatic registration 6.2 35 35 35 36 36 37 37 37 37 37 37 38 38 39 40 40 40 40 40 41 42 43 43 43 43 43 44 45 45 45 46 47 48 49 50 51 52 53 53 53 53 53 54 54 55 56 56 56 59 59 60 61 62 63 66 67 67 68 68 69 6.3 Manual settings 6.4 Service language Reader settings Settings via the Kaba test program 6.4.1 6.4.2 Service Interface 6.5.1 6.5.2 Remote access Accessing the service interface locally from the B-Client HR30 terminal software. Accessing the service interface locally from the BaseApp 6.5.3 6.6 Android system settings Network settings Settings for adjustment to the environment 6.5 6.7 6.8 6.6.1 6.6.2 Reader initialization 6.7.1 6.7.2 MIFARE (ARIOS) 6.7.3 MIFARE (Baltech) SFTP server LEGIC 4 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Table of Contents Preconditions Establishing an SFTP connection Information on the key file Important directories and files 6.8.1 6.8.2 6.8.3 6.8.4 Remote setup 6.9 Operation Touch screen 7 7.1 Operating elements 7.2 Display 7.3 7.4 Navigation keys 7.5 7.6 7.7 7.8 Function keys Input prompt Error states RFID reader Biometric reader Swipe reader Symbols for user guidance 7.8.1 7.8.2 7.8.3 7.8.4 CardLink 7.8.5 BaseApp 7.9.1 7.9.2 7.9.3 Finger entry Starting the application App management System Information 7.9 7.10 B-Client HR30 terminal software 7.10.1 Starting the terminal software 7.10.2 Shutting down the terminal software 7.10.3 Info functions 7.10.4 Registering new fingerprints at the terminal 8 8.1 Maintenance Backup battery 8.1.1 Replacement of the uninterruptible power supply UPS510 Battery change 8.2 8.3 Cleaning the housing 8.4 Installation/Update of the terminal software 8.4.1 8.4.2 8.4.3 8.4.4 Data backup Preparing installation/update Performing an update Performing the installation 8.5 Android update 9 9.1 9.2 9.3 Packaging/Returns Complete devices Electronic components Labelling 10 Disposal Index 69 69 70 71 72 73 73 73 73 74 75 75 76 77 77 78 79 79 80 81 81 82 84 85 85 86 87 88 92 92 92 93 93 94 94 94 94 95 95 96 96 96 97 98 100 04043552 - 05/2017 DRAFT Terminal 97 00 5 Technical Manual Table of Contents 04043552 - 05/2017 DRAFT Terminal 97 00 6 Technical Manual About this document 1 About this document 1.1 Validity This document describes the product:
Product designation:
Terminal 97 00 Product ID:
Item number 9700-K6 04079701 Terminal software:
735-05-X-K02 - B-Client HR30 BaseApp:
771-05-X-K02 Kaba test program 797-05-X-K02 Date of manufacture:
From April 2017 This document describes all product versions and all optional features and functions. Options are subject to a charge and therefore only available if purchased. Additional features and functions may not be available at the time the document is issued and may only be available for purchase at a later date. 1.2 Target group This quick start guide is intended for skilled persons only. The descriptions are intended for skilled persons trained by the manufacturer. The descrip-
tions are no replacement for product training. For reasons of equipment safety, the installation, maintenance and service measures de-
scribed in this documentation should only be carried out by skilled persons in accordance with EN 62368-1 (Audio/Video, Information and Communication Technology Equipment Part 1:
Safety Requirements). Skilled person is the designation for people who have the appropriate technical training and experience in setting up the equipment. Skilled persons are expected to use their training and experience to identify any risks to themselves and others that may arise while carrying out these activities, and to minimise these risks as far as possible. It is the skilled persons re-
sponsibility to ensure that the conditions stated by the manufacturer and the applicable regu-
lations and standards are complied with when carrying out these actions. This documentation is also used to provide information for persons with the following tasks:
Project planning and implementation Putting the product into operation within a network Connecting the product to the user software by programming customer applications Customer-specific adjustment through parameter setting on the product 1.3 Content and purpose Content is limited to the assembly, installation, commissioning and basic operation of the product. 04043552 - 05/2017 DRAFT Terminal 97 00 7 About this document Technical Manual 1.4 Using the document To make it easier to find specific topics, please refer to the following document guidelines:
The contents list at the start of the document provides an overview of all topics. The headings also list the relevant main chapter. Cross-references provide the number of the chapter in which more information can be found. Example [ 5.7]. There is an alphabetical index at the end of the document. 1.5 Additional documentation Specific parametrization of the terminal software:
B-Client HR30 reference manual Web interface for commissioning:
Service interface reference manual Kaba ARIOS security concept and required system adjustments for different MIFARE media:
Kaba MIFARE adjustments reference manual Supplementary documentation is available on the Kaba website. Technical manuals can be found in a secured area of the website. Access is only granted after a valid login. An account must be set up before logging in for the first time. Opening login screen:
1. Open your internet browser and go to http://www.kaba.com. 2. Choose your language in the top right-hand corner of the screen. 3. Under 'Products', choose either the 'Access Management' or 'Workforce Management'
product division. In the top right-hand corner of the screen, click on the following symbol:
4. 5. Enter your email address and password to log in or create a new account (see below). The technical manuals can be found under 'Downloads'. Creating an account:
1. Click 'Create account'. 2. Fill in the data fields and confirm your entries. A confirmation link will be sent to your email address. 3. Click on the confirmation link in your email to activate your account. 8 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual About this document 1.6 Warnings Warnings with information, instructions and forbidden actions to prevent personal injury and material damage are highlighted. Please note the warnings! These are intended to help avoid accidents and prevent damage. 1.6.1 Hazard categories Warnings are divided into the following categories:
DANGER High risk Designates an imminent danger resulting in serious injuries or death. WARNING Medium risk Designates a potentially dangerous situation which can result in serious injuries or death. CAUTION Low risk Indicates a potentially dangerous situation that can lead to minor injury. NOTICE Important information about the correct use of the product. Non-adherence to the notes can lead to malfunctions. The product or something in its vicinity could be damaged. 1.6.2 Symbols Depending on the hazard source, the following symbols are used for warnings. General hazard Hazard caused by electric power Risk of explosion Risk to electronic components caused by electrostatic discharge 1.7 Information Information is designated by an info symbol. Tips for usage, useful information. These help to make the best use of the product and its functions. 04043552 - 05/2017 DRAFT Terminal 97 00 9 About this document Technical Manual 1.8 Instructions Structure and symbols of the instructions are illustrated in the following example:
Prerequisite 1. Step 1 Interim result 2. Step 2 Result 10 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Basic safety information 2 Basic safety information This product has been built according to the latest technology and accepted safety regula-
tions. Nevertheless, handling this product can pose a risk to people and property. Read and observe the following safety information before using the product. 2.1 Proper use This product has been designed exclusively for use as set out in the chapter Product Descrip-
tion. Any other use will be deemed improper use. The manufacturer accepts no liability for any resulting damage. The user/operator bears sole responsibility for the risk. 2.2 Assembly and installation Check the device for visible damage caused by transport or wrong storage. Do not start up any damaged device!
Assembly and installation of the product may only be done by skilled personnel (see chapter 1 Target group). Mains voltage installations may only be carried out by a certified specialized company or au-
thorized electricians. The product should only be installed in locations which fulfil the environmental and technical conditions specified by the manufacturer. The manufacturer is not liable for damage arising due to improper handling or incorrect in-
stallation. 2.3 Service and maintenance Conversions and modifications to the product may only be done skilled personnel (see chapter 1 Target group). Any conversions and modifications performed by other persons will exempt us from any liability. The elimination of faults and maintenance work may only be performed by skilled personnel
(see chapter 1 Target group). 2.4 Accessories and spare parts Accessories and spare parts must comply with the technical requirements of the manufac-
turer. This is guaranteed with dormakaba original accessories and spare parts. 04043552 - 05/2017 DRAFT Terminal 97 00 11 Basic safety information Technical Manual 2.5 Electrical hazards Installations involving the mains power may only be executed by approved specialist compan-
ies or authorized skilled electricians. WARNING Live connections at the docking station in devices equipped with integrated power supply unit
(BEX120 motherboard) Carelessness can result in an electric shock. The terminal housing may only be removed from the docking station by skilled personnel. Before removing the terminal housing from the docking station, the device must be de-en-
ergized. For permanently connected devices, the voltage must be switched off. For devices supplied by a separable connection, the mains plug must be pulled. Secure against being switched on again. Check for absence of voltage. 2.6 Handling of lithium batteries To back up the real-time clock RTC, the device is equipped with a lithium manganese dioxide battery type CR2032. The battery is located on the rear side of the terminal housing. CAUTION Lithium batteries can explode or burst explosively. Improper handling of lithium batteries may result in fires and explosions. Replace lithium batteries only with batteries of the same type. Do not open, drill through or squash lithium batteries. Do not burn lithium batteries or expose them to high temperatures. Do not short-circuit lithium batteries. Do not recharge lithium batteries. 12 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Basic safety information 2.7 ESD protective measures NOTICE Danger of damage to electronic components from electrostatic discharge. If electronic printed circuit boards and components are handled incorrectly, damage may oc-
cur which leads to their complete breakdown or sporadic faults. When installing and repairing the product, the general ESD protective measures are to be observed. When handling electronic components, wear the ESD wrist strap. Connect the end of the strap to an ESD socket or an unpainted, earthed metal component. This will safely and ef-
fectively conduct charges away from your body. Only handle the edges of printed circuit boards. Do not touch printed circuit boards or connecting plugs. Put removed components on an anti-static surface or in an anti-static shielding container. Avoid contact between printed circuit boards and clothing. The wrist strap only protects the printed circuit boards from static electricity on the body. Damage can still occur due to static electricity on clothing. Only transport and ship removed modules in ESD-shielding, conductive protective con-
tainers. 2.8 Environmental protection It is prohibited to dispose of the device in your domestic waste. Used devices contain valuable materials that should be recycled. Properly dispose of used devices. Dispose of consumed batteries in accordance with state and local regulations. Carefully store the batteries to be disposed of to avoid short circuits, crushing or destruction of the battery casing. 04043552 - 05/2017 DRAFT Terminal 97 00 13 Product description Technical Manual 3 Product description 3.1 Overview The terminal 97 00 can be used for time and attendance and for providing customer-specific information and applications. The operating system used of the terminal 97 00 is 'Android. This allows applications, so-
called apps, to be used flexibly at the terminal. The system can be expanded at any time to make it suitable for a wide range of tasks or also be supplemented by apps specifically de-
veloped for customer requirements. For time and attendance, the B-Client HR30 terminal software is available. This terminal software makes the device compatible in terms of data records with its predecessor series B-
web and B-net, allowing it to be connected to the host system via UDP using the communica-
tion software B-COMM. Connecting it to HTTP/HTTPS-based applications, such as b-comm ERP5, b+ or EACM, is also possible. To display information, the terminal is equipped with a 7' colour display with a resolution of 800 x 480 pixels. The device is equipped with a touch screen operated by touching the glass front. The time data is recorded by a RFID proximity reader and/or a biometric CBM reader (de-
pending on design) A proximity sensor activates the device in the sleep or standby mode. The terminal is equipped with an integrated microphone and an integrated loudspeaker and, optionally, with a camera system. Communication takes place via Ethernet. Alternatively and optionally, communication can also take place via UMTS or WLAN. Optionally, 2 outputs (relays) and 4 digital inputs are available for control functions. 14 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Product description 3.2 Technical data 3.2.1 System Android version 5.0.2 (Lollipop) BECO620 single-board CPU unit Operating system CPU Memory Card slot for microSD or microSDHC card Parameters and data records are retained without supply voltage. 2 GByte DDR3 RAM 8 GByte eMMC Flash RTC The device has an integrated real-time clock. The function of the RTC is ensured for about 2 years by a lithium battery type CR2032 (on the rear side of the device) even without power supply of the device. Backlit with white LED TFT LCD display module Size: 17.8 cm (7.0) Resolution: 800 x 480 pixels (16:9/WVGA) Display Colour depth: 24-bit (true colour) Touch screen Optional splinter protection Biometric proximity sensor Optic proximity sensor for activating the biometric reader (option) Terminal proximity sensor 7 PCAP touch screen over the complete display 10-finger multitouch support Resolution: 30 x 18 (x/y) Range 10-50 mm, sensitivity adjustable in 3 steps, can be switched off Activates the device from the sleep or standby mode when approaching it within approx. 0.5 m 3.2.2 Multimedia Camera (option) Audio Integrated inch camera; resolution 5 megapixels Integrated microphone Integrated loudspeaker with power amplifier (3 W) 3.5 mm line-out jack 04043552 - 05/2017 DRAFT Terminal 97 00 15 Product description 3.2.3 Technical Manual IEEE802.3 compatible10BASE-T/100BASE-TX /1000BASE-T Auto sensing, Auto MDIX IEEE802.1x security concept, EAP type MD5 Encryption: WPA-PSK, WPA2-PSK and WEP security Interfaces/Communication Ethernet interface WLAN (option) Mini PCIe WLAN adapter conforming to IEEE802.11 b/g/n (2.4 GHz) Mobile radio (option) Mini PCIe HSPE module UMTS/HSPA: 850/900/1900/2100MHz GSM/GPRS/EDGE: 850/900/1800/1900 MHz Serial interface RS-232 (option) Hardware handshake (RTS/CTS) USB Baud rates: 9600/19200/38400/57600/115200 1 x USB 2.0 (host); 5 V/500 mA;
for example for connecting an external reader 3.2.4 Reader Depending on model, the device supports the following readers:
RFID reader MRD - LEGIC prime/advant, MIFARE Classic/DESFire HID - iCLASS SE, iCLASS, Prox, Prox II HITAG - EM4102, HITAG1, HITAG2 Biometric fingerprint reader Optionally as CBM-E with extended approvals (PIV-IQS with FBI certification and FIPS Biometric module (CBM) with integrated database for fingerprints. 201 approved template evaluation) Depending on model, the reader has a storage capacity for 500, 3000 or 5000 persons (2 fingers per person) Swipe reader in substructure housing Magnetic stripe tracks 1, 2, 3 Red light barcode Infrared barcode 3.2.5 Inputs/Outputs 2 relay outputs (option) One potential-free switchover contact each Contact loading capacity: 30 V AC/DC; max. 2 A 4 digital inputs (option) Galvanically isolated from system Input voltage: max. 30 V DC, min. -30 V DC 16 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Product description 3.2.6 Power supply For the power supply of the device, the following alternatives are possible:
PoE (Power over Ethernet) Mains power input (docking station with BEX120 motherboard required) PoE (Power over Ethernet) Power supply of the terminal via the 8-wire Ethernet cable (max. 100 m) 24 V DC power supply (docking station with BEX121 motherboard required) In accordance with IEEE802.3at/type 1 class 0 (0,44-12,95 W) Supported feed processes: Spare pair feed and phantom feed Voltage range: 100240 V AC Frequency: 50/60 Hz Mains voltage input Current consumption: max. 200 mA 24 V DC power supply Current consumption: max. 1 A Voltage range: 2230 V DC Only power supply units that fulfil the following requirements may be used for power supply:
LPS (Limited Power Source) and SELV (Safety Extra Low Voltage) in accordance with IEC/
EN/UL/CSA 60950-1 or ES1 and PS2 in accordance with IEC/EN/UL/CSA 62368-1. 3.2.7 Uninterruptible power supply UPS510 (option) The UPS510 consists of an electronic part with charging circuit and a rechargeable battery. The components are housed in a self-contained housing. Uninterruptible operation of the device in case of power supply failure is ensured by an NiMH battery with a capacity of 2100 mAh. The battery is fully charged after a charging time of 10 hours. The UPS510 ensures operation in case of power supply failure for up to 30 minutes or approx. 200 bookings, whatever occurs first. Condition: New battery, 100% charged, temperature 20 - 25 C. 3.2.8 Ambient conditions Ingress protection according to IEC 60529 IP20 (devices with swipe reader) IP40 (devices with RFID and CBM readers) Prerequisite: Cable entry from below using the enclosed grommets 5% - 85%, non-condensing Relative humidity Ambient temperature
-5 C +45 C (operation without UPS) 0 C +40 C (operation with UPS)
-25 C +70 C (storage without UPS)
-20 C +45 C (storage with UPS) 04043552 - 05/2017 DRAFT Terminal 97 00 17 Product description Technical Manual 3.2.9 Dimensions all dimensions are given in mm. 3.2.9.1 Terminal housing 3.2.9.2 Terminal with substructure housing 18 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Product description 3.2.9.3 Docking station 3.2.9.4 Surface-mounted protective metal housing (accessories) 04043552 - 05/2017 DRAFT Terminal 97 00 19 Product description Technical Manual 3.2.9.5 Flush-mounted housing (accessories) 20 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Product description 3.3 Conformity This product conforms to the following standards:
EN 62368-1:2014 EN 55032:2015 EN 55024+A1:2015 according to the provisions of the EU directives 2014/35/EU - Low Voltage Directive (LVD) 2014/30/EU - Electromagnetic Compatibility (EMC) The RFID readers MRD (LEGIC & MIFARE) and HID iCLASS SE / Prox used in this product comply with the following standards EN 300330-2 V1.6.1 EN 301489-3 V1.6.1 according to the provisions of the EU directive 2014/53/EU - Radio Equipment Directive (RED) RoHS This device complies with the regulations of the Directive 2011/65/EU of the European Parlia-
ment and of the Council of June 8, 2011, on the restriction of the use of certain hazardous substances in electrical and electronic equipment. The original conformity declaration can be downloaded in PDF format from www.kaba.com/
conformity. In addition, the product also complies with the following standards UL60950-1:2007/R:2014-10 CAN/CSA-22.2 No. 60950-1:2007/A2:2014-10 UL62368-1:2014-12 CAN/CSA-22.2 No. 62368-1:2014-12 FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.107 and 15.109 (Class B) IC Industry Canada Radio Standards Specifications ICES-003 Issue 5, Sections 5(a)(i) and 5(b)(i) Class B (ITE) The RFID readers MRD (LEGIC & MIFARE) and HID iCLASS SE / Prox used in this product comply with the following standards FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.207, 15.209, 15.215 and 15.225 IC Industry Canada Radio Standards Specifications RSS-GEN Issue 4, Sections 8.8, 8.9, 8.10 and RSS-210 Issue 8, Section A2.6 (Category I Equipment) 04043552 - 05/2017 DRAFT Terminal 97 00 21 Product description Technical Manual 3.4 Marking The rating plate is located on the underside of the device. Information given on the rating plate:
Item number Serial number Designation of the device Date of manufacture Connection data (supply voltage) CE marking WEEE marking according to DIN EN 50419 22 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Construction and function 4 Construction and function 4.1 Device structure The device consists of the terminal housing (1) and the docking station (2). The docking station is the wall mounting element of the device and, depending on the equip-
ment, the docking station contains additional electronics. 04043552 - 05/2017 DRAFT Terminal 97 00 23 Construction and function Technical Manual 4.1.1 Terminal housing - Front The terminal housing is the core device. The terminal housing essentially contains the CPU, the TFT display with touch screen and up to two internal readers. Integrated camera (option) Proximity sensor Infrared LED for proximity sensor 1 2 Camera flash (option) 3 4 5 Biometric reader (option) 6 Substructure housing with alternative RFID reader or swipe reader (option) 7 RFID reader (option) 8 TFT LCD display with PCAP touch screen 24 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Construction and function 4.1.2 Terminal housing - Rear side After removing the terminal housing from the docking station, the terminal rear side becomes accessible. The rear side of the terminal housing contains, among other things, the connection area and card slots. Audio line-out (3.5 mm jack) 1 2 USB port 3 Ethernet port (RJ45 socket) 4 CR2032 lithium battery for back-up of the RTC real-time clock 5 Card slot for a micro SIM card 6 Card slot for a microSD or microSDHC card 04043552 - 05/2017 DRAFT Terminal 97 00 25 Construction and function Technical Manual 4.1.3 Docking station The docking station is the wall mounting element of the device and is part of the standard equipment. The docking station is fastened to the wall. The terminal housing is placed on the docking station and secured. The docking station has cut-outs for entry of the installation cables. The installation cables can be entered from below and from the rear. Long holes for wall mounting Locking pin for the terminal housing 1 Motherboard (option) 2 3 Motherboard/terminal housing contact 4 5 Snap-in retaining tabs for the terminal housing 6 Connection terminal for the relay outputs 7 RJ45 connection for an external reader via RS-232 8 Cut-outs for cable entry from the rear 9 Cut-outs for cable entry from below 10 Cable clamps 11 Connection terminal for the additional interface (option) 12 Connection terminal for the inputs 26 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Construction and function 4.1.3.1 Docking station without motherboard In its basic equipment, the docking station does not include any electronics. In this case, the docking station serves as pure wall mounting element. Communication takes place via the Ethernet network. The device is supplied with power via PoE (Power over Ethernet). This is why only the network cable has to be connected to the ter-
minal housing. The network cable can be introduced into the docking station from the rear or from below. 04043552 - 05/2017 DRAFT Terminal 97 00 27 Construction and function Technical Manual 4.1.3.2 Docking station with motherboard Optionally, the docking station is equipped with a motherboard. The motherboard is available in 3 different versions. The differences refer to the design of the power supply. Otherwise, the motherboards are identical. BEX122 motherboard - Power supply via PoE BEX121 motherboard - Power supply by 24 V DC BEX120 motherboard - Power supply by mains voltage In general, the motherboard has the following hardware equipment:
RS-232C interface The RS-232C interface can be used for connecting an external reader, for example a CCD bar-
code scanner. It is connected to the RJ45 socket of the motherboard. Additional interface The motherboard has a slot for an optional interface module. The BEX301 - RS-232C interface or BEX302 - RS-485 interface can be used. The interface can be used for customized applications. The additional interface is without use in the standard equipment. The interface signals are connected via a 6-pin terminal on the motherboard. Outputs The motherboard has 2 relay outputs with changeover contacts. The relays can be used, for example, for activating door openers or signal generators. Inputs The motherboard has 4 digital inputs. The inputs can be used for a door opener key, access control or a customized application. Sabotage contact Devices whose docking station is equipped with a motherboard are provided with a sabotage contact. The sabotage contact is activated when the terminal housing is disconnected from the dock-
ing station plus motherboard. This causes the device to generate an appropriate alarm record. Prerequisite: Device supplied via PoE or via a UPS510. Not possible for devices supplied by the motherboard and not equipped with a UPS, since after removal of the terminal housing from the docking station the power supply is also disconnected. Whether hardware options are supported, depends in part on the terminal software used and the acquired software options!
28 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Construction and function 4.1.3.3 Docking station with BEX122 motherboard The BEX122 motherboard is used in devices whose power supply takes place via PoE. The BEX122 motherboard is not equipped with an additional power supply unit nor with a power supply input. 4.1.3.4 Docking station with BEX121 motherboard For power supply of the device, the BEX121 motherboard has a 24 V DC input with over-
voltage protection and transient filter. This motherboard is used when the device is supplied with 24 V DC. 4.1.3.5 Docking station with BEX120 motherboard The BEX120 motherboard has a 100240 V AC mains voltage input and an integrated limited power source power supply unit (LPS). This motherboard is used when the device is supplied with mains voltage. 04043552 - 05/2017 DRAFT Terminal 97 00 29 Construction and function Technical Manual 4.1.3.6 Overview of the equipment Equipment/Motherboard none BEX120 BEX121 BEX122 Power supply PoE 24 V DC Mains voltage Interfaces RS-232C interface Additional interface Inputs/Outputs 2 relay outputs 4 digital inputs 4.1.4 Interface assignment COM port Assignment X X X X X X X X X X X X X X X X COM1 COM2 COM3 COM4 Internal reader (integrated into terminal housing) Internal reader (integrated into terminal housing) Additional interface (docking station motherboard) RS-232 for external reader (docking station motherboard) 4.1.5 Uninterruptible power supply UPS510 The uninterruptible power supply UPS510 ensures operation in case of short-term power sup-
ply failure. The UPS510 is snapped into place on the rear side of the terminal housing. The UPS510 can be retrofitted or replaced at any time. 30 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Construction and function 4.2 Product versions 4.2.1 Basic equipment 7 WVGA display 7 touch screen Proximity sensor Ethernet 10/100/1000 Power supply via PoE (Power over Ethernet) Terminal housing Docking station Docking station as wall mounting element without electronics 4.2.2 Optional equipment (not retrofittable) Multimedia Camera Communication WLAN Mobile radio Reader integrated into terminal housing Reader in additional substructure housing Magnetic card reader Barcode swipe reader Other RFID readers RFID reader (MRD, HID, HITAG) Biometric fingerprint reader (CBM/CBM-E for 500, 3000 or 5000 persons) 4.2.3 Optional equipment (retrofittable) Protection in case of power supply failure Uninterruptible power supply UPS510 Docking station with motherboard BEX120, BEX121 and BEX122 motherboards:
RS-232C interface for connecting an external reader Adapter for additional interface 2 relay outputs 4 digital inputs BEX121 motherboard:
Power supply input for external 24 V DC BEX120 motherboard:
Power supply connection for mains voltage 4.2.4 Accessories Elastic protective frame Surface-mounted protective metal housing Flush-mounted housing 04043552 - 05/2017 DRAFT Terminal 97 00 31 Construction and function Technical Manual 4.3 Terminal software 4.3.1 BaseApp The BaseApp is the user interface of the android-based terminal. The BaseApp is part of the basic equipment and forms the platform for all applications (apps) used on the terminal. The BaseApp essentially performs the following functions:
Protection of the operating system from unauthorized access (system isolation). Only controlled access to the android operating system is possible. Organization and start-up of applications (apps). Provision of functions and interfaces for access to the hardware. Provision of service functions via a web interface (service interface) for commissioning and maintenance of the device. 4.3.2 Kaba test program The Kaba test program application (TP) has already been installed on the terminal ex works. The test program app offers the following functions:
Adjustment of various system settings locally to the device Retrieval of system information Testing of individual system components 4.3.3 B-Client HR30 terminal software The B-Client HR30 terminal software allows the device to be used as time and attendance terminal. The B-Client HR30 terminal software makes the device compatible in terms of data records with terminals of the B-web and B-net series, allowing it to be connected to the host system via the communication software B-COMM. 4.3.4 B-Client HR30 software options The usable range of functions of the device is given by the options activated in the 'sop.ini li-
cence file by means of the corresponding licence key. Some software options require an appropriate hardware equipment. Upon purchasing an additional software option later on, the existing licence file must be re-
placed with the new extended licence file. The sop.ini is located in the following directory
/data/data/com.kaba.apps.hr/files/init. From the parameters, you can determine which functions are active. The relevant parameters are located in the [BClientHR30] section. Each parameter has the value true or false. 32 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual 4.3.4.1 Licence for the B-Client HR30 terminal software. Entry in the licence file:
[BClientHR30]
BClientHR30Enabled=true Construction and function 4.3.4.2 CardLink Entry in the licence file:
CardLinkEnabled=true Enables CardLink update and CardLink validation in connection with LEGIC or MIFARE read-
ers. 4.3.4.3 Data encryption Entry in the licence file:
EncryptionEnabled=true Data encryption via Ethernet UDP in connection with the communication software B-COMM. Data encryption via HTTPS with XML communication. 4.3.4.4 Door control Entry in the licence file:
AccessControlEnabled=true Hardware prerequisite: Docking station with motherboard Enables:
Use of 4 inputs for door surveillance and door opening. Use of 2 relay outputs for door opening or break signal control Check for time profiles:
Check for double access. PIN check. 4.3.4.5 LocalEnrollment Entry in the licence file:
LocalEnrollmentEnabled=true Enables the registration of new fingerprints via the biometric reader locally at the terminal. 4.3.4.6 Memory options Entry in the licence file (possible values: 0, 1, 2, 3, 4):
BufferConfiguration=
The following overview shows the maximum possible number of data records in the respective memory option. Record type/Option 0 1 2 3 4*
4 Master records Registration records Update records*
Validation records*
200 10,000 400 200 1,000 10,000 2,000 1,000 2,000 10,000 4,000 2,000 10,000 10,000 20,000 10,000 30,000 30,000 60,000 30,000 50,000 50,000
-
-
*in connection with CardLink 04043552 - 05/2017 DRAFT Terminal 97 00 33 Construction and function Technical Manual 4.3.4.7 Starting native apps Entry in the licence file:
NativeAppEnabled=true Enables the start of native apps from B-Client HR30. 4.3.4.8 Partner application Entry in the licence file:
PartnerinterfaceEnabled=true Supports partner applications. Partner application is called from B-Client HR30 with data transfer. 4.3.4.9 Browser start Entry in the licence file:
BrowserEnabled=true Enables the browser to be started from B-Client HR30. Transferred data can be displayed or web sites can be loaded. 4.3.4.10 Replacement terminal Entry in the licence file:
ReplacementEnabled=true Identifies a replacement terminal. In connection with the communication software B-COMM, the terminal can be easily and comfortably replaced with a device containing the same hardware when servicing is required. The licence file of the replaced device is automatically adapted during commissioning and in-
stalled in the replacement terminal. 34 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Construction and function 4.4 System connection This chapter describes the principle of host host connection and applies exclusively to devices with B-Client terminal software. For detailed descriptions, please refer to the reference manual of the terminal software. 4.4.1 Communication principle Communication between the terminal 97 00 and a superior host computer takes place via an Ethernet network as standard. Data exchange between the B-Client HR30 terminal software and the customer application takes place via a communication software. The communication software transmits the data records collected by the terminals to files or transmits them to the customer application via a defined interface. 4.4.2 Parametrization The varied functions of the terminal depend in particular on the set parameters. Parametriza-
tion allows extensive adaptation to a wide range of applications. During parametrization the currently valid parameters are changed and stored in the memory of the terminal. The re-
quired parameters are provided by the customer application and transmitted to the terminal in the form of parameter records. 4.4.3 Authorizations Information relevant to authorizations are provided by the customer application in the form of personnel master records. All information relating to a certain badge number or group is stored in the master record. The master record contains information on authorizations, time profiles, person-related dis-
play texts and the PIN number. Master records can be stored in the terminal. This allows the terminal itself to decide whether a booking is authorized. Whether a booking is authorized, can also be inquired by the host in the 'online operating state. In this case, no master records are required in the terminal. Mas-
ter records can be transmitted to the terminal at any time, resulting in the current master re-
cord being overwritten. Individual master records can be deleted by the host. Likewise, master records can be requested by the host. The number of master records that can be loaded to the terminal depends on the device hard-
ware and on the licensed memory configuration. 4.4.4 Data from the terminal After a booking, the terminal generates a registration record. The registration records con-
tains the information who has booked when at which terminal by pressing which function key. At what time this registration record will be transmitted to the host computer, depends on the operating state of the terminal. Certain states and events result in the generation of alarm records and status records. 04043552 - 05/2017 DRAFT Terminal 97 00 35 Construction and function Technical Manual 4.4.5 Operating states 4.4.5.1 Online After a booking, the terminal carries out the parametrized tests and enters the test result in the registration data record as error detection. The registration data record is transmitted to the host. Following this, the terminal expects a logical booking response from the host. Along with it, the host communicates to the terminal the decision whether or not the booking is au-
thorized. If the terminal does not receive a logical booking response from the host, it will switch to the offline operating state and decide itself based on the parametrized tests whether the booking is authorized. As soon as the host can be reached again, all data records saved in the mean-
time in offline will be transmitted to the host. Then the terminal automatically switches again to the online operating state. 4.4.5.2 Offline After a booking, the terminal carries out the parametrized tests and decides immediately whether or not the booking was authorized by sending an internal booking response. Depend-
ing on the parametrization, registration records are stored in the terminal. As soon as the host can be reached, all data records saved since the last transmission will be transmitted to the host. 4.4.5.3 Autonomous After a booking, the terminal carries out the parametrized tests and decides immediately whether or not the booking was authorized by sending an internal booking response. Depend-
ing on the parametrization, registration records of authorized and unauthorized bookings are stored in the terminal. If the host can be reached, any error and alarm records that may be available will be trans-
mitted to the host. The saved registration data records are transmitted to the host on request together with a special data record. 4.4.6 Devices with biometric reader Biometric software When communicating via B-COMM, the program package B-COMM - Biometrics option is re-
quired for managing and distributing the finger templates. Communication with the Finger Template Control Service (FTCS) of the biometrics software takes place via Ethernet/UDP and a separate channel. When connected to HTTP/HTTPS-based applications, the distribution of the finger templates also takes place via the HTTP/HTTPS host channel. Standalone mode Alternatively, operation without a biometric host is also possible. In this Standalone mode, all fingerprints of persons must be registered by the reader of the terminal. In this case, the fin-
ger templates are only saved in the readers internal database. If they get lost, all persons have to be registered again at the terminal. This is why the Standalone mode without biometric software is only recommended for very small solutions (max. 20 persons). 36 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Construction and function 4.5 Authentication types Devices equipped with biometric reader can be operated in 5 authentication modes. Modes 2 to 5 require an additional RFID reader. 4.5.1 Mode 1: Identification Mode 1 is the typical biometric identification The biometric features of all persons authorized to book are registered by an enrollment sta-
tion and distributed to the individual readers. During a booking the fingerprint of the person is registered. The biometric features are com-
pared to the data records If a matching reference data record is found, the person has been identified. The associated ID is sent in the registration data record to the superior access con-
trol manager. 4.5.2 Mode 2: Verification Mode 2 is a verification based on time profiles. The person's biometric data is stored on the RFID badge, which is used for verification. First, a person books using the RFID badge. The ID segment and the biometric segment are read. The master record and biometric time profile check shows whether a biometric verifica-
tion is required. If a verification is required, the biometric reader is activated. This is the request for the person to put on the finger. The registered biometric features are now compared to the data saved in the biometric segment. If the features of the fingerprint are identical, the booking is valid. 4.5.3 Mode 3: Verification (ID) Mode 3 is a verification based on time profiles of two identification features. The ID of the RFID badge is compared to the ID of biometric identification. First, a person books using the RFID badge. The ID segment is read. The master record and biometric time profile check shows whether an additional biometric identification is carried out. If a biometric identification is required, the biometric reader is activated. This is the request for the person to put on the finger. The biometric features are compared to the data records of the reader's internal database. If the matching reference data record is found, the two IDs are compared. If the IDs are identical, the booking is valid. 4.5.4 Mode 4: Combination of modes 1 and 2 Mode 4 allows parallel use of biometric identification and biometric verification based on time profiles. A maximum of 5000 persons can be authenticated per identification. If this capacity is insufficient, further persons can be authenticated by verification. 4.5.5 Mode 5: Combination of modes 2 and 3 Mode 5 allows parallel use of verification based on time profiles and verification (ID). This al-
lows parallel operation of RFID badges with and without biometric segment. 04043552 - 05/2017 DRAFT Terminal 97 00 37 Construction and function Technical Manual 4.5.6 Alternative types of authentication For people with less defined biometric characteristics an alternative way of authentication can be enabled. This is made possible by storing a biometric identification in the personnel master record, see reference manual of the terminal software. The following options are possible instead of biometric identification:
Entry of the ID on the keypad (only mode 1) Entry of the ID via the RFID badge 4.5.7 Additional PIN entry A PIN entry via the keypad can be requested via the time profile for all types of authentication
(see reference manual of the B-Client terminal software). In order to increase security, an additional PIN should be requested, following the alternative entry of the ID number. 38 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Construction and function 4.6 CardLink Principle Mechatronic CardLink components, i.e. passage ways without connection to a physical net-
work, are generated and configured together with the online components in a central system. All authorizations can be managed and assigned in a common access profile. The access rights are stored on the user medium. Each user medium must be validated at regular intervals at an online reader. If certain condi-
tions (entry-access authorization, participation in CardLink) are met, a type of validity stamp is written onto the medium. Access is only granted on the CardLink component (4) if the cor-
responding entry-access authorizations are available and the validation is correct. Thanks to this mechanism, a user medium registered as lost is either actively locked (withdrawal of the validation) or loses its authorization automatically after validation expires. Commissioning of the CardLink components CardLink components can be digital locking cylinders (actuators), cabinet locks, registration units/readers/terminals, etc. The Kaba programmer is the link between the system and the standalone component. The Kaba programmer is used to transmit all basic parametrizations manually to the Card-
Link components: Generally, the following initialization data are transferred to the CardLink component: Management area number, door number, time zones, validity period of the valid-
ation and component name. Writing authorization profiles to a badge for the first time With the help of the software, the authorization profiles for employees, visitors, outside com-
panies, etc. are defined and written once to a segment of the badge, for example using an au-
thorization reader. Validation function During validation a new time stamp is stored on the badge, while the authorization profiles remain unchanged. Within the time stamp, the badge user can enter certain areas and pass through doors in accordance with his authorization profiles. The time stamp can be written on the badge using an authorization reader or a CardLink-capable terminal. After the time window has expired, the authorization becomes void. Update function An update is carried out whenever authorization profiles on a badge undergo changes. This is the case, for example, when an employee changes in-house to a new area of responsibility and therefore receives other authorizations for doors, rooms, etc. Upon holding her badge in front of the time and attendance terminal and pressing the update key, the new authorization pro-
files will be written to the badge. The employee can now move freely in the building inside the enabled areas and within the stored time zones. Media The following badge technologies are supported:
CardLink Version 1.0 CardLink Version 1.1 LEGIC prime LEGIC advant, MIFARE Classic and MIFARE DESFire 04043552 - 05/2017 DRAFT Terminal 97 00 39 Installation Technical Manual 5 Installation 5.1 Installation conditions 5.1.1 General An accurate installation of all components is a basic requirement for a properly functioning device. The following installation instructions must be adhered to. 5.1.2 Installation site Distances RFID fields which are close together can influence one another, thereby reducing the reading and writing distances. An all-round clearance of 20 cm must be maintained between two devices with RFID readers. Mounting height Recommended mounting height 140 cm to the top edge of the terminal. Electromagnetic fields Do not install the device in the vicinity of strong electromagnetic fields caused, for example, by switched-mode power supplies, electric power lines, phase control etc. Electromagnetic fields can adversely affect read performance or cause malfunctions, especially in the case of contactless RFID readers. Electromagnetic fields may impair the touch screen functions. Sun irradiation Direct sun irradiation leads to reflections within the display area (resulting in poor readability of the display.) Direct sun irradiation may impair the function of the biometric reader. Direct sun irradiation may impair the function of the proximity sensors. Avoid installation at places with direct sun irradiation. 5.1.3 Connections The following connectors must have been prepared at the installation site of the terminal:
Power supply for the terminal Ethernet network (in case of host communication via Ethernet) Signal lines to inputs/outputs (optional). 40 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Installation 5.1.4 Power supply 5.1.4.1 PoE power supply For PoE power supply [}3.2.6], a PSE (Power Sourcing Equipment) must be provided on the network cable for power feeding. Possible methods for feeding the power supply via the PSE:
End span (direct supply, e.g. via PoE switch) Midspan (supply via intermediate sources, e.g. PoE injector) 5.1.4.2 24 V DC power supply Devices with docking station equipped with BEX121 motherboard. It has a 24 V DC input with overvoltage protection and transient filter for supplying power to the terminal. Only power supply units that fulfil the following requirements may be used for power supply:
LPS (Limited Power Source) and SELV (Safety Extra Low Voltage) in accordance with IEC/
EN/UL/CSA 60950-1 or ES1 and PS2 in accordance with IEC/EN/UL/CSA 62368-1. 5.1.4.3 Mains voltage supply Only devices with docking station equipped with BEX120 motherboard. It has a 100-240 V AC mains voltage input and an integrated limited power source power supply unit (LPS). The mains voltage supply can be designed as stationary wiring or as separable connection. For the terminal, a separate fuse-protected circuit must be provided. If the mains voltage supply is designed as a separable connection, the following applies:
The mains socket with grounded contact must be in the immediate vicinity of the device. The mains plug must be freely accessible. If the mains voltage supply is designed as stationary wiring, the following applies:
An easily accessible circuit breaker must be provided. The circuit breaker (LS) must be designed for max. 10 A. The electrical system of the building must be equipped with an all-pole supply circuit switch. 04043552 - 05/2017 DRAFT Terminal 97 00 41 Installation Technical Manual 5.1.5 Cable entry The installation cables can be inserted into the device housing from below or from behind. Cut-outs for inserting the installation cables are available in the docking station. The ingress protection to IEC 60529 specified in the technical data is only guaranteed if the cable is introduced from below by means of the delivered cable grommets or cable glands. Cable entry from below Cable entry from the rear If the cable entry is made from the rear side of the device, the mounting position of the ter-
minal must be defined at an early stage and discussed with the cable installer. 42 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Installation 5.2 Installation lines 5.2.1 24 V DC power supply A 3-wire cable is required for supplying power to the terminal
(+24 V/0 V/ground wire). The housing of the terminal must be connected to earth. Therefore, the ground wire must be carried from the power supply to the terminal. The terminal is designed for the following max. wire sizes:
Diameter (): 2.7 mm Cross-section: 2.5 mm2 AWG number: 12 In case of long lines, the voltage drop due to line resistance will have to be taken into account. 5.2.2 Mains voltage supply A 3-wire cable is required for the mains voltage supply (phase/zero/protective conductor). The terminal is designed for the following max. wire sizes:
Diameter (): 2.7 mm Cross-section: 2.5 mm2 AWG number: 12 5.2.3 Ethernet Network cable with RJ45 plug, line requirement: CAT.5 S-UTP 4 x 2 AWG 24 oder AWG 22 (ac-
cording to EIA/TIA568) or higher quality. 5.2.4 Inputs/Outputs The terminals for the signal lines are designed for the following max. wire sizes:
Diameter (): 0.3 1.4 mm Cross-section: 0.08 1 mm2 AWG number: 28 - 16 Recommended cable:
CAT.5 S-UTP 4 x 2 AWG 24 or AWG 22 (according to EIA/TIA568) or higher. 04043552 - 05/2017 DRAFT Terminal 97 00 43 Installation Technical Manual 5.3 Fastening the docking station First make the required cut-outs for introducing the installation line(s). Introduce the install-
ation lines from below or from the rear. Fastening the docking station, dimensions in mm. The docking station is mounted directly to the wall using screws/dowels. There are three oval fastening holes(1) in the docking station for fastening. Fastening material (included in the delivery):
3 wood screws 4.5 x 35 (2) 3 washers (3) 3 dowels 6 mm (4) The washers (3) cover the fastening hole (1) completely after tightening the screw. The de-
livered washers must also be used if you use other fastening screws (depending on the mounting surface). In case of soft mounting surfaces, make sure that the housing is not pressed into the surface when mounting it. The unevenness of the mounting surface may not exceed 0.5 mm. The unevenness of the mounting surface may have to be compensated for or adjusted by means of suitable meas-
ures (e.g. washers). If the mounting surface is not even, we recommend using the mounting plate (5). It is placed between the wall and the docking station. The relatively rigid mounting plate avoids mechan-
ical distortion of the docking station. The mounting plate is available as accessory under the order number 04043450. 44 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Installation 5.4 Connections Establish connections in de-energized state only!
5.4.1 Connecting the network cable The Ethernet connection (RJ45 socket) is located on the rear of the terminal housing. The network cable should protrude approx. 15 to max. 18 cm from the wall so that the dis-
tance between docking station and terminal housing is enough to easily plug in the network connector. The network cable is then stored in a loop in the pocket on the rear of the terminal housing. 5.4.2 Connecting the mains voltage Only devices with BEX120 motherboard!
Installations at the mains voltage may only be executed by a trained electrical specialist. The mains line is de-energized. 1. Connect the mains line to the terminal. 2. Secure the N and L wires with a cable binder (1). 04043552 - 05/2017 DRAFT Terminal 97 00 45 Installation Technical Manual 5.4.3 Mains fuses Only devices with BEX120 motherboard!
The mains fuses are located under the sheet metal cover (1). Remove the cover in the follow-
ing way:
The mains power supply is off. 1. Unscrew the screw (2), TORX T10. 2. Unscrew the M4 nut (3) using a wrench with size 7. 3. Push the sheet metal cover (1) slightly upwards (unhinge it) and remove it The mains voltage is secured with fuses on 2 poles. The fuses (4) are of the plug-in type and can be easily replaced. 4 = 2x subminiature fuse (radial) T 1.0 A/250 V, order number 04037221 The fuses may only be replaced with fuses of the same type. 46 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Installation 5.4.4 Connecting 24 V DC power supply Only devices with BEX121 motherboard!
For the power supply of the device, use only power supply units that fulfil the requirements to EN60950-1:2006 as limited power source. Connect the 24 V DC power supply and the ground wire to the terminal (1). Fuses for the 24 V DC power supply The 24 V DC power supply is secured with fuses on 2 poles. The fuses (2) are of the plug-in type and can be easily replaced. 2 = SMD fuse T 1.0 A/125 V, order number 04036925 The fuses may only be replaced with fuses of the same type. 04043552 - 05/2017 DRAFT Terminal 97 00 47 Installation Technical Manual 5.4.5 Digital inputs Only devices with optional motherboard and B-Client HR30 Door control software option. 4 digital inputs are available. The inputs can be used for a door opener key, access control or a customized application. Assignment of inputs E1 to E4 depends on the configuration. The inputs can be controlled by a simple switch or a relay contact. The corresponding input is connected to common ground. An open input is recognized as high due to the internal pull-up resistor. Ground potential equals low. Level High = + 4.5 V to + 30 V or open Low = - 30 V to + 1.5 V 48 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Installation 5.4.6 Relay outputs Only devices with optional motherboard and B-Client HR30 Door control software option. Two potential-free relay outputs with one change-over contact each are available. Contact loading capacity: 30 V AC/DC; max. 2 A The function and assignment of relays 1 + 2 depend on the settings of the terminal software. For inductive loads that are supplied with direct current, the included diode (a freewheeling diode) must be connected parallel to the load to suppress interference. Make sure that the di-
ode is connected in reverse-bias direction. When using an AC voltage power supply, the in-
cluded varistor type S10K30 must be connected in parallel. The diode or varistor must be connected directly to the load and must not be fitted in the ter-
minal. 04043552 - 05/2017 DRAFT Terminal 97 00 49 Installation Technical Manual 5.4.7 Connecting an external reader Only devices with optional motherboard!
An additional external reader, for example a CCD barcode scanner, can be connected to the device. The reader can be connected to the COM4 port of the device. Further hardware and software options are not required. To ensure correct function, the reader must be configured and activated via the Service inter-
face [}6.5] or the Kaba test program [}6.4.2]. 1 2 RJ45 connection for reader with RS-232C levels. The barcode scanners provided by Kaba as accessories work with RS232C levels. Fuse for the power supply of the external reader, SMD fuse T375 mA, order number 04107874 Assignment of the RJ45 socket (1) 1 2 3 4 5 V DC; max. 300 mA
-
GND
-
5 6 7 8 TxD (of the reader)
-
-
-
Hardware handshake is not supported, no transmission delay for scanner data, communica-
tion parameters: 9600, 8, N, 1 (can be set). Power supply for the reader The power supply of the external reader can take place via the 5 V DC of the RJ45 socket. The maximum allowed current is 300 mA. 50 Terminal 97 00 DRAFT 04043552 - 05/2017 18 Technical Manual Installation 5.5 Uninterruptible power supply UPS510 The device may optionally be equipped with the uninterruptible power supply UPS510. The UPS510 is snapped into place on the rear side of the terminal housing. The UPS510 can be ret-
rofitted at any time. Inserting UPS510 To hold the UPS510, a recess is located on the rear of the terminal. The contact is located in the upper part. 1. Slide the UPS510 with the contact on the underside forward into the recess as far as it will go. 2. Press the lower part of the UPS510 against the terminal until the holder locks into place. Removing UPS510 1. Unlock USSV510 by pressing the detent lever towards the UPS. 2. Extract the lower part of the UPS510 and then pull it downwards and remove it. 04043552 - 05/2017 DRAFT Terminal 97 00 51 Installation Technical Manual 5.6 Fasten the terminal housing to the docking station. NOTICE For safety reasons (device safety and personal protection), the electronic components and connections in the docking station may not be openly accessible. Therefore, the terminal must be installed directly after the docking station if you use devices with optional motherboard in the docking station. For devices with docking station without motherboard (PoE), the terminal housing may also be installed later on. Fasten the terminal housing (1) as follows to the docking station (2):
1. Plug the network cable into the RJ45 socket on the rear of the terminal housing and lay the cable in a loop in the pocket on the rear of the terminal housing. 2. Push the terminal housing (1) into the docking station (2) until the lateral tabs (3) lock into place. Make sure that the terminal housing does not get jammed!
3. Secure the terminal housing on the docking station with the safety screw M4x10 TORX-TR
(3). This requires a SoftFinish TORX T20H screwdriver with a bore in the tip for TORX screws with locking pin. Only devices with optional screw-in wall-mounted version. 1. Screw countersunk screws (4) into the tabs. This requires a TORX T8 screwdriver. 52 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Commissioning 6 Commissioning 6.1 Network requirements Start-up and communication in regular operation are done via an Ethernet network. To guarantee unhindered and trouble-free data traffic, the UDP ports used for communica-
tion must have been enabled. The firewall configuration must therefore be adapted accordingly. 6.1.1 Communication The UDP port used for communication between B-COMM and the terminal must have been enabled. The UDP port is in the range from 7700 hex. to 77EF hex. (30464 dec. to 30703 dec.), depend-
ing on configuration. 6.1.2 Comparing finger templates Devices equipped with a biometric CBM reader require another UDP port for exchanging bio-
metric data. The UDP port used for the FTCS or BCFTC stream must have been enabled. The UDP port is in the range from 7800 hex. to 78EF hex. (30720 dec. to 30959 dec.), depend-
ing on configuration. 6.1.3 Automatic registration via B-COMM The network must have been equipped with a working DHCP server. It must be possible to transfer UDP data packages unhindered to the B-COMM server. IP address 239.255.255.250, UDP port 1900 dec. and UDP port 7900 (30976dec.) must have been enabled. The SSDP service has to be enabled in the Windows service management. The SFTP connection via the standard port 22 must have been enabled. 04043552 - 05/2017 DRAFT Terminal 97 00 53 Commissioning Technical Manual 6.2 Automatic registration via B-COMM Start-up of the terminal takes place largely automatically in connection with the communica-
tion software B-COMM. The device is preset at the factory for automatic registration via B-COMM. For communication via WLAN, the connection must have been previously set up and activ-
ated. This is done via the system settings. B-COMM communication software version 4.0 and higher. System requirements Network with a working DHCP server. Start-up procedure 1. Connect the power supply for the device. After booting, the device cyclically reports to the B-COMMs active in the network. At this point, until start-up by a B-COMM is complete, the message Waiting for registration is displayed on the dis-
play. Once the device is detected by B-COMM, the relevant data that identifies the device will be queried. If the device is not known, it will be entered in B-COMM under the B-COMM Terminal Discovery client under BCTDS (Terminal Discovery Stream). 2. Add device in B-COMM to the desired communication channel. 3. Provide device with the appropriate communication parameters. After having assigned the device permanently to B-COMM, B-COMM first updates the settings of the device and then makes a backup of the settings together with the
'sop.ini licence file. The device now reports to the B-COMMs active in the network that registration has been carried out, after which the device will be removed again from the BCTDS stream by the other B-COMMS. 4. Load specific parameters and master records to the device. The terminal software is restarted automatically. After that, the device is ready-to-oper-
ate. 6.2.1 Cancelling automatic registration Automatic registration via B-COMM can be cancelled, in order to perform settings, for ex-
ample, manually. The device is waiting for registration by B-COMM. The message Waiting for registration is shown on the display. 1. Touch the Back icon 2. Confirm cancellation. Cancellation takes place after no more than 10 seconds, followed by starting the terminal in the navigation bar. software. The device can be reset to the registration mode via the Service Interface. 54 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Commissioning 6.3 Manual settings Configuration and parameter setting of the terminal are done largely via the B-COMM communication software. Manual settings can be made locally on the device or from a remote location. Settings locally on the device:
Settings via the Service interface [}6.5]
Settings via the Kaba test program [}6.4]
Android system settings [}6.6]
Options for making settings from a remote location:
Remote setup [}6.9]
Service Interface [}6.5]
Network settings To change network settings, for example assignment of a fixed terminal IP address, the fol-
lowing options are available:
Locally on the device via Android system settings [}6.6]
Locally on the device via Service interface [}6.5]
Remote via the Service interface [}6.5]
Condition: The device must already have an IP address, which must be known. 04043552 - 05/2017 DRAFT Terminal 97 00 55 Commissioning Technical Manual 6.4 Settings via the Kaba test program The Kaba test program is in general installed on the device. Apart from various test and info functions, the Kaba test program also offers the option to make system-specific settings, such as the configuration of the readers. Loading the settings of the Kaba test program The start screen of the Base App [}7.9] is displayed. 1. Touch the icon designated TP. The Kaba test program is started. 2. Select Settings. The settings of the Kaba test program are displayed. 6.4.1 Service language This function allows you to select the language for service texts and the Kaba test program. 6.4.2 Reader settings Configuration of the internally and externally connected readers. These reader settings correspond to the device configuration at the time of delivery. The func-
tion is usually only required if an external reader is connected at a later stage or if LEGIC is switched over to MIFARE in connection with an MRD reader. 56 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Commissioning 6.4.2.1 Reader type Depending on the device, up to three readers can be configured. The reader type connected to the respective interface is set under Type. If no reader is available, NONE must be set as reader type. Type Supported readers NONE LEGIC_4200 MIFARE MIFARE_4200 BIOMETRIC_CBM HID_ICLASS_SE_PROX HID_PROX HID_ICLASS BARCODE MAGNETIC SPECIAL2 SPECIAL TRANSPARENT No reader connected RMs SM-4200 LEGIC advant & SM-4200-M (MRD in LEGIC mode) Kaba MIFARE (ARIOS security concept) RMs SM-4200-M (MRD in MIFARE mode) Biometric CBM reader HID iCLASS SE / prox reader HID proximity reader HID iCLASS reader Barcode, CCD barcode scanner Magnetic swipe, Baltech MIFARE, Hitag Reader with serial FLI2/FLI3 Reader with serial FLI Special applications Devices with MRD reader (multi-reader device) Devices with MRD reader (RMs SM-4200-M) support LEGIC or MIFARE media, depending on the reader type set. For LEGIC media, the LEGIC_4200 reader type has been factory-preset. For processing MIFARE media, the reader type must be changed to MIFARE_4200. LEGIC media are configured in the same way as pure LEGIC readers by means of an SM-4200 chip via the files mediaact.ini and mediadef.ini. MIFARE media are configured in the same way as the predecessor Kaba MIFARE via the sys-
tem.ini file. 6.4.2.2 Interface To set the interface the reader is connected to. The device supports up to three readers. Depending on options, the reader assignment of the COM ports is as follows:
First internal reader Second internal reader External reader COM2 (RFID) COM2 (substructure reader) COM2 (RFID) COM1 (CBM) COM1 (CBM) COM1 (CBM) COM4
-
-
COM4 COM1 (substructure reader) COM4 COM4
-
COM2 (RFID) COM4 COM2 (substructure reader) COM4 04043552 - 05/2017 DRAFT Terminal 97 00 57 Commissioning Technical Manual 6.4.2.3 Guard time The guard time is used to avoid accidental double bookings. After a booking, the next badge will not be read until the guard time has expired. The time is given in ms. Presetting = 2000 ms. 58 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Commissioning 6.5 Service Interface The service interface provides the functions that are required for start-up, maintenance, and diagnostics of the device. Operation and a detailed description of the service functions can be found in the following documentation:
Service Interface reference manual 6.5.1 Remote access The service interface is provided by the web server integrated into the device. Access takes place via the network connection of the device, either directly or via the network. For direct connection, an Ethernet cross-over cable (crossed RJ-45 cable) or an Ethernet patch cable 1:1 can be used (Auto MDIX). The service interface can be accessed from a service PC via a web browser by typing the device IP address into the address box. 04043552 - 05/2017 DRAFT Terminal 97 00 59 Commissioning Technical Manual 6.5.2 Accessing the service interface locally from the B-Client HR30 terminal software. Access the service interface from the B-Client HR30 terminal software B-Client HR30 terminal software has been started [}7.9.1] and is in the Basic view. 1. Touch the Back icon in the navigation bar [}7.4]. By default, the actuating time is 4 seconds, but can be adjusted to between 1 and 15 seconds. After the set actuating time has expired, the password prompt appears. 2. Enter a password or leave the field empty if no password has been stored. NOTE: No password has been stored for the device in its delivery state. A password can be assigned using the parameter records X02/X12. See reference manual of the terminal software. 3. Press OK to confirm. NOTICE! Three invalid password entries will lock the dialog. It must then be unlocked via the parameter record I2. 4. Select Settings. The start page of the service interface appears on the display. Without any touch interaction, the service interface will be automatically closed again after 3 minutes. 60 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Commissioning 6.5.3 Accessing the service interface locally from the BaseApp Access the service interface from the BaseApp. The start screen of the Base App is displayed. 1. Touch the Back icon in the navigation bar [}7.4]. A menu appears in the lower display area 2. Touch Preferences A BaseApp function selection is displayed. 3. Touch 'Launch Service Interface' under Service Interface. The start page of the service interface appears on the display. Without any touch interaction, the service interface will be automatically closed again after 3 minutes. 04043552 - 05/2017 DRAFT Terminal 97 00 61 Commissioning Technical Manual 6.6 Android system settings System-specific settings, connection settings, such as assignment of a fixed IP address, can be made via the android system settings. Access the android system settings The start screen of the Base App is displayed. 1. Touch the Settings application. The main menu of the android system settings is displayed. 62 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Commissioning 6.6.1 Network settings Open the Ethernet menu:
The main menu of the android system settings is displayed. 1. Select Ethernet under Wireless & networks. The menu containing the Ethernet functions is displayed. 6.6.1.1 Displaying the current network configuration The menu containing the Ethernet functions is displayed. 1. Select Ethernet connection details. The current network configuration is displayed. Example:
04043552 - 05/2017 DRAFT Terminal 97 00 63 Commissioning Technical Manual 6.6.1.2 Adjusting the Ethernet settings The menu containing the Ethernet functions is displayed. 1. Select Ethernet - configure Ethernet devices The Ethernet settings are displayed Requesting an IP address from the DHCP server 1. Activate DHCP. 2. Apply setting by pressing Save and leave the function. Static IP configuration 1. Activate Static IP. 2. Enter network parameters. 3. Apply setting by pressing Save and leave the function. 64 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Commissioning 6.6.1.3 Network security The terminal supports the following authentication procedure for access controls to the local network:
EAP (Extensible Authentication Protocol) according to IEEE 802.1x EAP type MD5 with identity and password Configuration of IEEE 802.1x authentication The menu containing the Ethernet functions is displayed. 1. Select Configure network authentication IEEE 802.1x under Security. 2. Select EAP method (MD5), enter identity and password. 3. Touch Start 04043552 - 05/2017 DRAFT Terminal 97 00 65 Commissioning Technical Manual 6.6.2 Settings for adjustment to the environment Display brightness The display brightness can be adjusted as follows:
The main menu of the android system settings is displayed. 1. Select Display under Device. The display functions are displayed. 2. Select Brightness level. 3. Use the slide control to set the desired brightness. Sleep setting After a defined time without user activity, the display brightness is automatically reduced. The time until this sleep mode is initiated can be set in a range between 15 seconds and one hour. The sleep mode can also be deactivated. The sleep setting can be adjusted as follows:
The main menu of the android system settings is displayed. 1. Select Display under Device. The display functions are displayed. 2. Select Sleep. 3. Select desired time or deactivate function (Never). The sleep mode is finished when the internal motion sensor detects a person or any user activ-
ity takes place at the device. Volume setting The volume for the acoustic operator guidance via the system loudspeaker can be adjusted as follows:
The main menu of the android system settings is displayed. 1. Select Sound & notification under Device. The sound settings are displayed. 2. Use the Media volume slide control to set the desired volume. 66 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Commissioning 6.7 Reader initialization Some RFID readers must be initialized during initial start-up. 6.7.1 LEGIC LEGIC readers require a reader launch in certain cases:
If a read-protected segment is to be used. If writing to a write-protected segment is to be done, for example during a CardLink ap-
plication. Reader launch The reader launch requires an SAM 63 card (security card C2) containing the correspond-
ing segment area. 1. Hold the SAM 63 card in front of the reader if the device expects an RFID input in normal operation. The start of the sequence is confirmed by means of an acoustic signal. Three successive acoustic signals are output if the process cannot be executed, for ex-
ample if the reader has already been launched. 2. The SAM 63 card must be present uninterruptedly in the reading area for about 15-20 seconds. After a successful launch, 3 short acoustic signals are output. Eight successive signals are output when an error occurs. 3. Remove the SAM 63 card from the field. Reader delaunch The reader is delaunched using an SAM 64 card. 1. Hold the SAM 64 card in front of the reader if the device expects an RFID input in normal operation. The start of the sequence is confirmed by means of an acoustic signal. Three successive acoustic signals are output if the process cannot be executed, for ex-
ample if the reader has already been launched. 2. The SAM 64 card must be present uninterruptedly in the reading area for about 15-20 seconds. After a successful delaunch, 3 short acoustic signals are output. Eight successive signals are output when an error occurs. 3. Remove the SAM 64 card from the field. 04043552 - 05/2017 DRAFT Terminal 97 00 67 Commissioning Technical Manual 6.7.2 MIFARE (ARIOS) In systems with ARIOS security concept, the site key must be distributed to the individual readers. The site key can be distributed in two ways. Site key distribution via B-COMM. Site key distribution via programming master A or B. For details, please refer to the reference manual of the terminal software. 6.7.3 MIFARE (Baltech) The MIFARE reader must be activated by a MIFARE configuration card:
1. Turn off the device. 2. Turn on the device. 3. Hold the MIFARE configuration card in front of the reader for about 10 seconds. 68 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Commissioning 6.8 SFTP server The device provides an SFTP server for a secure, encrypted connection via the 'Secure File Transfer Protocol (SFTP). 6.8.1 Preconditions For SFTP access to the terminal, the following is required:
SFTP client, for example WinSCP. WinSCP (Windows Secure CoPy) is a free 'open source SFTP and FTP client for Microsoft Windows. Kaba key file. The standard key file is available for download on the Internet at the Kaba site in the secured area (Extranet). The SFTP connection via the standard port 22 must have been enabled. 6.8.2 Establishing an SFTP connection After installation and start of the SFTP client, the login window appears. Required settings:
File protocol:
Host name:
Port number:
User name:
Password:
Private key file:
SFTP
<IP address> e.g. 10.10.11.79 22 root leave blank Select key file on local computer. 1. Make the following entries and settings 2. Click Login
. 3. Enter pass phrase. Pass phrase for standard key = kaba 04043552 - 05/2017 DRAFT Terminal 97 00 69 Commissioning Technical Manual 4. Click "OK"
The connection to the terminal is being established. 6.8.3 Information on the key file The device is equipped with a standard key file ex works. It can be replaced with an adjusted customized key file via the function 'SSH key replacement of the B-COMM communication software. The SSH key can be reset to standard via the service interface or the BaseApp settings locally on the device. 70 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Commissioning 6.8.4 Important directories and files Path: /data/data/com.kaba.apps.hr/files/
Directory File Description diagnosis init SSL transfer EEPROMsetting statisticsHR.dat application.ini b-client_xml.ini encoding.ini interface.ini labelinfo.ini sop.ini text.ini root.pem root.crt record.dat input.cmd reboot.cmd Parameter used for the system start Statistics Settings of the B-Client terminal software HTTP/HTTPS/XML function parameters Definition of special characters B-Client terminal software design Info texts Software licence file Texts for dynamic lists HTTPS certificates Transfer directory for control files, see chapter 6.9 Path: /data/data/com.kaba.apps.ba/files/
Directory File Description diagnosis init debug.err debug.log debug.bak communication.ini debug.ini mediaact.ini mediadef.ini system.ini terminal.ini Error logfile System logfile Backup of debug.log Communication settings Logging settings Settings for LEGIC 4200 reader System settings Terminal settings 04043552 - 05/2017 DRAFT Terminal 97 00 71 Commissioning Technical Manual 6.9 Remote setup The following settings can also be transferred to the device via SFTP [}6.8]:
Host configuration FTCS host configuration Reader settings This type of start-up should only be carried out by experienced system specialists. Procedure:
1. Establish SFTP connection to the device. 2. Load the following file in ASCII mode to the local computer:
/data/data/com.kaba.apps.hr/files/EEPROMsetting This file contains the parameter used for the last start. 3. Rename file to reboot.cmd. 4. Adjust the parameter values in the file accordingly. NOTE: Changes in the sections [General] and [Ethernet] will not be applied!
5. Enter RESET in the first line of the file. Example:
RESET
[Ethernet]
MAC Addr=00:07:cc:00:62:e4 Terminal Addr=10.10.5.85
... 6. Copy the reboot.cmd file to the following directory on the device:
/data/data/com.kaba.apps.hr/files/transfer/
The file will be identified within approx. 15 seconds and the parameter values will be ap-
plied. The terminal software is then restarted with the changed settings. 72 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Operation 7 Operation 7.1 Operating elements 1 Display and touch screen 2 Reader window for finger placement (only devices with optional biometric reader) 3 Entry field for RFID media (only devices with optional RFID reader) 4 Card swipe (only devices with optional swipe reader in substructure housing) 7.2 Display For displaying the user interface and outputting specific information, a 7 colour TFT display is used. 7.3 Touch screen The device has a 7 touch screen, which extends over the entire display surface. The touch screen is operated by touching the glass surface with a finger. 04043552 - 05/2017 DRAFT Terminal 97 00 73 Operation Technical Manual 7.4 Navigation keys By wiping from the right display edge to the left, the navigation bar is displayed. The naviga-
tion bar contains the android navigation keys. Upon touching the individual symbols, the following functions will be executed:
Home Upon touching the Home symbol, the desktop view (start screen) of the device opens. Since the android is capable of multitasking, active programs keep running in the background. Search Upon touching the search symbol, the search function for each active program is displayed. Menu Upon touching the menu symbol, a menu is displayed whose options refer to the current pro-
gram or the current screen display. Back Upon touching the Back icon, it is possible to return to the display view shown last in each case, i.e., for example, from the submenu to the main menu. When the system is expecting an input, a virtual keypad is shown on the display. In this input mode, the Back icon points downwards. Upon touching the Back icon, the input mode is fin-
ished, and the virtual keypad disappears. The Home key and Search key are without function within the B-Client HR30 terminal soft-
ware, test program and BaseApp. 74 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Operation 7.5 RFID reader Contact-free media are simply held in front of the entry field of the RFID reader on the ter-
minal. The reading process, in particular in connection with biometric verification or CardLink, can take several seconds. RFIDDo not remove the RFID medium from the input field until success-
ful read-in has been signalled. 7.6 Biometric reader The biometric reader is ready as soon as the reading window is lit. The finger must be placed in the centre of the reading window of the biometric reader. After a valid booking, a short acoustic signal can be heard. Finger position Only if finger position and pressure on the reader window are optimal, is a correct fingerprint read-in ensured. The finger has to be slightly humid. The finger has to be gently pressed onto the window. The fingerprint has to be in the centre of the reader window. 04043552 - 05/2017 DRAFT Terminal 97 00 75 Operation Technical Manual 7.7 Swipe reader Swiftly swipe magnetic-stripe badges and barcode badges through the reading bar in any dir-
ection. The magnetic stripe is on the back of the badge, pointing towards the scanning unit. The barcode is on the front of the badge, pointing towards the scanning unit. In connection with magnetic-stripe badges, automatic detection of the booking direction is possible. This function must be enabled by settings in the terminal software. Thus, for example, swiping from left to right can generate an IN booking and swiping from right to left an OUT booking. 76 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Operation 7.8 Symbols for user guidance The following standard symbols are available to the terminal software for user guidance. The symbols are part of the BaseApp. Display contents, functions and operating sequences depend on the terminal software set-
tings. 7.8.1 Function keys IN OUT Production data collection CardLink Official absence Cafeteria Break Query Time query Access 1 Access 2 Kiosk 1 Kiosk 2 Logfile 1 Logfile 2 Logfile 3 Visitor registration Additional settings Cloud News Room reservation Shift schedule 04043552 - 05/2017 DRAFT Terminal 97 00 77 Operation Technical Manual Briefing Master records Special function Time and attendance 1 Holiday Survey NFC Time and attendance 2 Time and attendance 3 Biometrics 7.8.2 Input prompt The following symbols signal to the operator what entry is currently expected. Badge entry via RFID reader or swipe reader expected. Finger entry via biometric reader expected. Entry of an RFID badge with bio-
metric segment for biometric verification expected. ID or PIN entry expected. If the system configuration alternatively allows for several entries, symbols with several pos-
sible entry types are displayed, for example:
Finger entry or badge entry or entry via keypad expected. Finger entry or entry via keypad expected. 78 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Operation 7.8.3 Error states The following symbols signal to the operator error states during a booking Invalid biometric verification Fingerprint is not identical to the finger template on the badge or finger tem-
plate does not exist. Invalid biometric verification No biometric segment on badge detected or error while reading finger tem-
plate. Invalid biometric identification The database of the CBM reader does not contain any finger templates (data-
base empty). Invalid biometric identification Finger not contained in database Reading error 7.8.4 CardLink When using the optional CardLink function, the following symbols are relevant. A CardLink update is available. During a CardLink validation or CardLink update, an error has occurred. 04043552 - 05/2017 DRAFT Terminal 97 00 79 Operation Technical Manual 7.8.5 Finger entry While the fingerprint is read in, the user is guided event-driven by the biometric reader. The following symbols are displayed to signal the error states to the user. Place finger more to the left. Place finger more to the right. Place finger more to the top. Place finger more to the bottom. Press finger more strongly. Latent finger Clean reading window of the biometric reader The database of the CBM reader does not contain any finger templates
(database empty). This state is displayed immediately after enabling the reader. 80 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Operation 7.9 BaseApp The BaseApp is the user interface shown after closing an application. The BaseApp essentially performs the following functions:
Protection of the operating system from unauthorized access (system isolation). Only controlled access to the operating system is possible. Organization and start-up of applications (apps). Provision of functions and interfaces for access to the hardware. 7.9.1 Starting the application On the start screen of the BaseApp, the applications (apps) available to the user are shown in the form of symbols (icons). Depending on the number of applications, this list can run over several pages. The number of pages is indicated by the dots below the list. The active page is characterized by a filled dot. Upon touching the corresponding icon, the application is started. For example, Kaba terminal software:
Icon HR30 = B-Client HR30 terminal software Icon TP = Kaba test program 04043552 - 05/2017 DRAFT Terminal 97 00 81 Operation Technical Manual 7.9.2 App management This function determines which applications (apps) are displayed on the start screen and are thus available to the operator. The order of the app icons can also be adjusted. In addition, a default application started automatically with the system can be defined. Starting app administration The start screen of the Base App is displayed. 1. Touch the Back icon in the navigation bar [}7.4]. 2. Select Preferences. 3. Select App management. The submenu of the app management is displayed. 82 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Operation 7.9.2.1 Managing the apps displayed The available applications (apps) are displayed in a list. To place an app on the BaseApp start screen, the check box on the right must be checked. On the left next to the app icon, the order number is shown. The order number indicates the order of the apps on the BaseApp start screen. To change the order, touch the icon of the cor-
responding app and move it to the desired position in the order. 7.9.2.2 Autostart for default app. If the function Enable switch to default app is active, the application defined under Select default app will be started automatically when starting the device. 7.9.2.3 Selection of the default app The function Select default app is used to define the default app. 04043552 - 05/2017 DRAFT Terminal 97 00 83 Operation Technical Manual 7.9.3 System Information The BaseApp menu can be used to display miscellaneous system information. Displaying system Information The start screen of the Base App is displayed. 1. Touch the Back icon in the navigation bar [}7.4]. 2. Select System Information. The system information is displayed. 84 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Operation 7.10 B-Client HR30 terminal software 7.10.1 Starting the terminal software In the start screen of the BaseApp [}7.9], the available applications (apps) are displayed. Touch the icon designated HR30 to start the B-Client HR30 terminal software. The B-Client HR30 user interface is shown on the display of the terminal. The appearance of the device software can be adjusted specifically for each customer and is therefore variable. Accordingly, the default user interface shown above must be considered an example. 04043552 - 05/2017 DRAFT Terminal 97 00 85 Operation Technical Manual 7.10.2 Shutting down the terminal software Shut down the B-Client terminal software as follows:
in the navigation bar [}7.4]. 1. Touch the Back icon NOTE: By default, the actuating time is 4 seconds, but can be adjusted to between 1 and 15 seconds. After the set actuating time has expired, the password prompt appears. 2. Enter a password or leave the field empty if no password has been stored. NOTE: No password has been stored for the device in its delivery state. A password can be assigned using the parameter records X02/X12. See reference manual of the terminal software. 3. Press OK to confirm. NOTICE! Three invalid password entries will lock the dialog. It must then be unlocked via the parameter record I2. The terminal software is shut down, and the BaseApp user interface [}7.9] is displayed. 86 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual 7.10.3 Operation Info functions In the menu of the B-Client HR30 terminal software, two info functions are available. B-Client HR30 terminal software has been started. [}7.10.1]
1. Touch the Menu icon in the navigation bar [}7.4]. After the set actuating time has expired, the password prompt appears. NOTE: By default, the actuating time is 4 seconds, but can be adjusted to between 1 and 15 seconds. 2. Enter a password or leave the field empty if no password has been stored. NOTE: No password has been stored for the device in its delivery state. A password can be assigned using the parameter records X02/X12. See reference manual of the terminal software. 3. Press OK to confirm. The menu is displayed. Host communication The following information is displayed:
B-Client HR30 version Terminal IP address Host IP address and port Group identification and device identification Current readers Network communication The following information is displayed:
Terminal IP address Network mask MAC address DNS Gateway DHCP server address 04043552 - 05/2017 DRAFT Terminal 97 00 87 Operation Technical Manual 7.10.4 Registering new fingerprints at the terminal The function Local Enrollment of the B-Client HR30 terminal software allows new finger-
prints to be registered via the biometric reader at the terminal. Prerequisites:
Terminal with biometric reader B-Client HR30 terminal software with Local Enrollment software option 7.10.4.1 Displaying the function B-Client HR30 terminal software has been started [}7.10.1]. 1. Touch the Menu icon in the navigation bar [}7.4]. After the set actuating time has expired, the password prompt appears. NOTE: By default, the actuating time is 4 seconds, but can be adjusted to between 1 and 15 seconds. 2. Enter a password or leave the field empty if no password has been stored. NOTE: No password has been stored for the device in its delivery state. A password can be assigned using the parameter records X02/X12. See reference manual of the terminal software. 3. Press OK to confirm. 4. Select 'Local Enrollment'. The main menu is displayed. The biometric mode and the current assignment of the in-
ternal reader database are additionally displayed. 88 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual 7.10.4.2 Enroll Operation This function allows persons to be registered via the biometric reader of the terminal. The fin-
gerprints are stored in the internal reader database. Operation with biometric software During normal operation with biometric software, the new finger templates are synchronized directly using the Finger Template Control Service (FTCS). The function 'Enroll is only executed if an FTCS connection is already available via the BCFTC stream. Standalone mode In standalone mode, the function is also executed without FTCS connection. Procedure 2 fingers per person are registered. 3 pictures are taken of each finger. To do so, each finger has to be briefly placed on the reader window three times. A quality value is specified for each registration process. The quality of the registered fingers is subdivided into three levels. Quality of number Quality of text
> 120 60-120
< 60 very good good poor Optimal finger position If the finger position is not ideal during enrollment, symbols to that effect are shown on the display [}7.8.5]. Registering a person 1. Select 'Enroll'. 2. Enter template ID. NOTE: The person is identified by means of the template ID. The length of the ID is preset by the 'PresetEnroll' parameter. 3. Press 'OK to confirm the template ID. 04043552 - 05/2017 DRAFT Terminal 97 00 89 Operation Technical Manual 4. Place first finger on the reading window. A successful read-in of a finger is confirmed by means of a short acoustic signal. 5. Remove finger briefly and then place it again. The hand symbol on the display signals which finger has to be placed which number of times (orange) and which fingers have been registered how many times (green). After successful registration of the 6 (2x3) finger prints, a green hand will be dis-
played. At the end of the procedure, the overall quality of the registered fingers and a prompt will be displayed, asking you whether you want to save the template. 6. If you want the finger template to be saved, press 'Yes to confirm. If the quality is poor, the procedure should be repeated. If the quality of a finger is re-
peatedly poor, a different finger should be registered. 90 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual 7.10.4.3 Unenroll Operation This function allows individual finger templates to be deleted from the reader database in standalone mode. The selection of the finger template to be deleted can take place in one of the following ways. Numpad The template ID is entered on the virtual keypad. Reader The finger whose template is to be deleted must be placed on the reader. List The template ID is selected from a list. 7.10.4.4 Identification This function allows identification of an individual. After calling the function, the finger has to be placed on the reader window. The associated ID is shown on the display. 7.10.4.5 List This function lists all template IDs stored in the database. The function is only available if the database contains fewer than 100 template IDs. After selecting an ID, it can also be deleted by pressing 'Unenroll. 7.10.4.6 Erase DB This function allows all finger templates to be erased from the local database of the reader. For safety reasons, you are prompted for a code. The Erase PIN is always '439235'. 04043552 - 05/2017 DRAFT Terminal 97 00 91 Maintenance Technical Manual 8 Maintenance 8.1 Backup battery To back up the real-time clock RTC, the device is equipped with a lithium manganese dioxide battery type CR2032. The battery is located on the rear side of the terminal housing. The backup battery must be replaced with a new one every 10years. 8.1.1 Battery change CAUTION Lithium batteries can explode or burst explosively. Improper handling of lithium batteries may result in fires and explosions. Replace lithium batteries only with batteries of the same type. Do not open, drill through or squash lithium batteries. Do not burn lithium batteries or expose them to high temperatures. Do not short-circuit lithium batteries. Do not recharge lithium batteries. 1. Remove the terminal housing from the docking station. 2. Remove UPS510 [}5.5] (if present) 3. NOTE: Do not use tools such as a screwdriver and the like. Remove the old backup battery carefully by hand from the battery holder. 4. Push the new battery into the holder until it snaps into place. 5. Mount UPS510 (if present) again. 6. Fasten the terminal housing again to the docking station. 7. Reset terminal time. 92 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Maintenance 8.2 Replacement of the uninterruptible power supply UPS510 To guarantee the buffer time as specified in the technical data, the uninterruptible power supply UPS510 has to be replaced every 3years with a new one. Perform dismounting and mounting of the uninterruptible power supply UPS510 as described
[}5.5]. 8.3 Cleaning the housing To clean the housing, use a soft, lint-free cloth and a mild window cleaning agent!
NOTICE Other agents may result in damage to the housing. Observe the following instructions in order to avoid producing damage to the housing and the reader window of the biometric reader (if present) during the cleaning process:
Do not use alcohol, such as ethanol and isopropanol Do not use aggressive solvents Do not use cleaning agents with added powder Avoid scratching and abrasive movements 04043552 - 05/2017 DRAFT Terminal 97 00 93 Maintenance Technical Manual 8.4 Installation/Update of the terminal software For the installation or update of the terminal software on the terminal, an installation tool is available. This so-called SFTP installer can be downloaded for the particular terminal soft-
ware in the secured area of the dormakaba website (Extranet). Installation For initial installation or in order to replace a faulty installation, a complete installation of the terminal software is required. The installation process will reset any settings already made. Update An update is performed in order to update the already existing terminal software to a new version. During an update process, only the program files will be replaced. Existing settings are re-
tained. 8.4.1 Data backup Before an update or a new installation of the terminal software is made, the following data must be backed up. Device configuration and parametrization If specific layout adjustments are made, the 'interface.ini file and pictures must be backed up on a local drive. 8.4.2 Preparing installation/update Authorization for access to dormakaba Extranet [}1.5]. 1. Download SFTP installer from dormakaba Extranet. 2. Unzip ZIP file to a local directory. 3. If the SSH key for SFTP access was changed:
Copy relevant key file (*.ppk) to the directory of the SFTP installer. In the 'Standard_Software.ini' file, enter the file name of the key file under 'Key_Path='. Format Key_Path='<File name>.ppk'
4. Start the installation tool by double-clicking 'SFTP Installer.exe'. The first prompt of the user guidance is displayed. 8.4.3 Performing an update 1. Select the device type. 2. Select 'Update. 3. Select terminal software (B-Client HR30) 4. Select add-ons (BaseApp + test program) 5. Enter IP address and SFTP access data. A summary of the installation data is displayed. 6. Start process. The process can take several minutes. Successful execution is confirmed by the install-
ation tool. 7. Restart the device. The terminal software is now up-to-date. 94 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Maintenance 8.4.4 Performing the installation 1. Select the device type. 2. Select 'Installation 3. Select terminal software (B-Client HR30) 4. Select add-ons (BaseApp + test program) 5. Enter IP address and SFTP access data. A summary of the installation data is displayed. 6. Start process. The process can take several minutes. Successful execution is confirmed by the install-
ation tool. 7. Restart the device. 8. Start-up of the device:
Perform host configuration, adjust reader settings in accordance with device configura-
tion, and transfer parameter and master records to the device. 8.5 Android update If an update of the operating system is required, it will be provided by the dormakaba Support in the form of the 'update.zip file. The 'update.zip file is copied to the directory/cache of the terminal via SFTP. The directory is interrogated by the system once a minute. If the file is detected, the operating system is updated automatically and then the terminal is restarted. 04043552 - 05/2017 DRAFT Terminal 97 00 95 Packaging/Returns Technical Manual 9 Packaging/Returns Components and devices that are not correctly packaged could be damaged during transport and result in costs. When sending dormakaba products, please observe the following notes. Dormakaba is not liable for damage to products caused by inadequate packaging. 9.1 Complete devices The original packaging is specially designed for the device. It offers the best possible protec-
tion against damage during transport. When returning goods, always use the original packaging!
If this is not possible, please use packaging that prevents the device from being damaged. Use a sturdy, thick-walled transport box or a cardboard box. The transport box should be large enough that there is 810cm space between the device and the edge of the con-
tainer. Wrap the device in suitable material or put it in a bag. Put generous padding around the device, e.g. foam padding or air cushions. The device must not be able to move around within the packaging. Only use dust-free, environmentally-friendly packaging material. 9.2 Electronic components ESD-sensitive electronic components such as printed circuit boards, readers etc. are to be stored, transported and shipped in suitable ESD protective packaging. Electronic components must only be packaged at ESD-proof work stations and carried out by people who are famil-
iar with and apply the general ESD protective regulations. Electronic components must be returned in packaging with sufficient ESD protection in order to make warranty claims in the event of malfunctions of any kind. Replacement of electronic printed circuit boards and components in the replacement pro-
cedure. To ensure high quality standards, electronic components delivered in packaging without suffi-
cient ESD protection will neither be analysed nor repaired, but rather forwarded on directly for disposal. 96 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Packaging/Returns 9.3 Labelling Including all returns paperwork and labelling the package correctly enables us to process your case quickly. Please ensure that a delivery note is enclosed in each package. The delivery note should contain the following information:
Item numbers, serial numbers, designations. Address of your company/contact person. Reason for return, e.g. repair exchange. Accurate description of fault. Number of devices or components in each package. In the event of returns from outside of the EU, a customs invoice with the real customs value and customs tariff no. will also be required. 04043552 - 05/2017 DRAFT Terminal 97 00 97 Disposal Technical Manual 10 Disposal This product complies with the WEEE directive and is, according to DIN EN standard 50419, marked with the WEEE symbol 'crossed-out wheeled bin. The symbol refers to separate disposal of electric and electronic devices in EU countries. According to the European WEEE directive, the device must not be disposed of together with domestic waste. The components of the device must be separately recycled or disposed of. Used devices con-
tain valuable materials that must be recycled. Poisonous and dangerous components can cause lasting damage to the environment if disposed of improperly. According to the German Electrical and Electronic Equipment Act (ElektroG), the system op-
erator has the duty to return electrical and electronic equipment at the end of their lifetime free-of-charge to the manufacturer, point of sale or public collection points established for this purpose. Disposal in Germany:
At the end of use of the goods supplied, Kaba GmbH will take them back for a proper disposal in accordance with the legal regulations (German Electrical and Electronic Equipment Act, ElektroG). Charges incurred for transport to the manufacturer will be at the expense of the owner of the waste electrical equipment. Disposal in Switzerland:
The equipment must be returned to an electrical equipment collection point according to VREG. In the EU, electrical and electronic equipment has to be disposed of according to national dis-
posal and environmental legislation. Deletion of person-related data Individuals are responsible for the deletion of their personal data. Dispose of packaging in accordance with environmental regulations. The packaging materials can be recycled. Please do not dispose of the packaging with house-
hold waste, instead send them for recycling. Lithium batteries To back up the real-time clock RTC, the device is equipped with a lithium manganese dioxide battery type CR2032. The battery is located on the rear side of the terminal housing. Remove battery before returning the device [}8.1]. Do not dispose of the batteries in your domestic waste. Used lithium batteries must be returned to a disposal system according to national and local regulations. To prevent short circuits and the resulting heating, lithium batteries must not be stored or transported unprotected. Examples of suitable measures against short circuits include:
Placing the battery in a plastic bag Covering poles with adhesive tape See also safety instructions in Handling of lithium batteries [}2.6]. Uninterruptible power supply UPS510 The device is optionally equipped with the uninterruptible power supply UPS510. The UPS510 contains an NiMH rechargeable battery. Remove UPS before returning the device [}5.5]. 98 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual Disposal Do not dispose of the UPS in your domestic waste!
The UPS must be disposed of according to state and local regulations. 04043552 - 05/2017 DRAFT Terminal 97 00 99 Index Index Numerical 24 V DC power supply A Ambient conditions Ambient temperature Android Android navigation keys Android system settings Android update App management Audio Audio line-out Authentication types Authorizations Automatic registration via B-COMM B Back BaseApp Basic safety information B-Client HR30 B-COMM BEX120 motherboard BEX121 motherboard BEX122 motherboard Biometric reader Biometric software Browser start C Cable entry Camera Cancelling automatic registration Card slot CardLink CE conformity Cleaning the housing Communication principle Conformity Connecting an external reader Connecting the mains voltage Connections Contact loading capacity Technical Manual 15 25 33 91 23 16, 48 18 18 15 66 98 26 33 72 98 89 13 25, 45 16 50 44 44 75 24 20 36 47 16 58 74 16 37 CPU unit CR2032 lithium battery D Data encryption Deleting finger templates Device structure Digital inputs Dimensional drawings Dimensions Display Display brightness Disposal Docking station Door control E EEPROMsetting ElektroG Enroll ESD protective measures Ethernet connection Ethernet interface External reader F Fastening material Fastening the docking station Finger position Flash Flush-mounted housing FTCS G Ground wire GSM Guard time H Home HSPE module I Identification 17, 47 17 17 15 74 62 95 82 15 25 37 35 54 74 32, 81 11 32 36 29, 45 29, 47 29 16, 75 36 34 42 15, 24 54 15, 25 33, 39 21 93 35 21 50 45 45 16, 49 100 Terminal 97 00 DRAFT 04043552 - 05/2017 Technical Manual IEEE 802.1x Info functions Ingress protection Ingress protection according to IEC 60529 Inputs Installation lines Installation of the terminal software Interfaces 65 87 17 42 16, 48 43 94 16 K Kaba test program L Language for service texts License file Lithium battery Local Enrollment LocalEnrollment Loudspeaker M MAC address Mains fuses Mains input fuse Mains voltage input Manual settings Marking Memory Memory options Menu Microphone microSD card Mobile radio Mounting height Mounting plate MRD reader Multimedia N Native apps Navigation bar Navigation keys Network cable Network connection Network requirements Network settings O Operating elements 56 56 32 25 88 33 15 87 46 46 17 55 22 15 33 74 15 25 16 40 44 57 15 34 74 74 43 45 53 63 73 Operating states Operating system Operating system update Outputs P Packaging Parametrization Partner application Power over Ethernet Power supply Proper use Protective conductor Protective housing Proximity sensor R Rating plate Reader Reader type Real-time clock RTC reboot.cmd Registering fingerprints Registering new fingerprints at the terminal Relative humidity Relay outputs Remote setup Replacement terminal Replacing the backup battery Returns RFID reader RoHS RS-232 RTC S Safety Safety information Search Service language SFTP server SIM card sop.ini SSH key Starting B-Client HR30 Starting the application Sun irradiation Supplementary documentation Surface-mounted protective metal housing Index 36 15 95 16 96 35 34 17 17 11 45 19 15, 24 22 16 57 92 72 89 88 17 16, 49 72 34 92 96 16, 75 21 16, 50 15 11 11 74 56 69 25 32 70 85 81 40 8 19 04043552 - 05/2017 DRAFT Terminal 97 00 101 Technical Manual Index Swipe reader Symbols System System connection T Terminal housing Terminal software update Test program Time and attendance Touch screen U UMTS Unenroll Uninterruptible power supply Update of the terminal software update.zip UPS510 USB USB port User interface V Verification Volume setting W Washer WEEE Directive WLAN 76 74 15 35 24 94 32, 56 32 15 16 91 17, 51 94 95 17, 51 16 25 81 37 66 44 98 16 102 Terminal 97 00 DRAFT 04043552 - 05/2017
frequency | equipment class | purpose | ||
---|---|---|---|---|
1 | 2017-11-06 | 13.56 ~ 13.56 | DXX - Part 15 Low Power Communication Device Transmitter | Original Equipment |
2 | 0.125 ~ 0.125 | DCD - Part 15 Low Power Transmitter Below 1705 kHz |
app s | Applicant Information | |||||
---|---|---|---|---|---|---|
1 2 | Effective |
2017-11-06
|
||||
1 2 | Applicant's complete, legal business name |
dormakaba EAD GmbH
|
||||
1 2 | FCC Registration Number (FRN) |
0014591184
|
||||
1 2 | Physical Address |
Albertistrasse 3
|
||||
1 2 |
Villingen-Schwenningen, N/A D-78056
|
|||||
1 2 |
Germany
|
|||||
app s | TCB Information | |||||
1 2 | TCB Application Email Address |
v******@tuvam.com
|
||||
1 2 | TCB Scope |
A1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
|
||||
app s | FCC ID | |||||
1 2 | Grantee Code |
NVI
|
||||
1 2 | Equipment Product Code |
SE3200
|
||||
app s | Person at the applicant's address to receive grant or for contact | |||||
1 2 | Name |
M******** J******
|
||||
1 2 | Telephone Number |
+49 7********
|
||||
1 2 | Fax Number |
+49 7********
|
||||
1 2 |
m******@dormakaba.com
|
|||||
app s | Technical Contact | |||||
n/a | ||||||
app s | Non Technical Contact | |||||
n/a | ||||||
app s | Confidentiality (long or short term) | |||||
1 2 | Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | Yes | ||||
1 2 | Long-Term Confidentiality Does this application include a request for confidentiality for any portion(s) of the data contained in this application pursuant to 47 CFR § 0.459 of the Commission Rules?: | No | ||||
if no date is supplied, the release date will be set to 45 calendar days past the date of grant. | ||||||
app s | Cognitive Radio & Software Defined Radio, Class, etc | |||||
1 2 | Is this application for software defined/cognitive radio authorization? | No | ||||
1 2 | Equipment Class | DXX - Part 15 Low Power Communication Device Transmitter | ||||
1 2 | DCD - Part 15 Low Power Transmitter Below 1705 kHz | |||||
1 2 | Description of product as it is marketed: (NOTE: This text will appear below the equipment class on the grant) | RFID Reader | ||||
1 2 | Related OET KnowledgeDataBase Inquiry: Is there a KDB inquiry associated with this application? | No | ||||
1 2 | Modular Equipment Type | Limited Single Modular Approval | ||||
1 2 | Purpose / Application is for | Original Equipment | ||||
1 2 | Composite Equipment: Is the equipment in this application a composite device subject to an additional equipment authorization? | Yes | ||||
1 2 | Related Equipment: Is the equipment in this application part of a system that operates with, or is marketed with, another device that requires an equipment authorization? | No | ||||
1 2 | Grant Comments | Limited Single Modular Approval. This module is only approved for use when installed in the model: 9700-K6. Compliance of this device in all final host configurations is the responsibility of the Grantee. | ||||
1 2 | Is there an equipment authorization waiver associated with this application? | No | ||||
1 2 | If there is an equipment authorization waiver associated with this application, has the associated waiver been approved and all information uploaded? | No | ||||
app s | Test Firm Name and Contact Information | |||||
1 2 | Firm Name |
TUV SUD Product Service GmbH
|
||||
1 2 | Name |
M******** B****
|
||||
1 2 | Telephone Number |
49942********
|
||||
1 2 | Fax Number |
+49 9********
|
||||
1 2 |
m******@tuev-sued.de
|
|||||
Equipment Specifications | |||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
1 | 1 | 15C | CC | 13.56000000 | 13.56000000 | ||||||||||||||||||||||||||||||||||||
Line | Rule Parts | Grant Notes | Lower Frequency | Upper Frequency | Power Output | Tolerance | Emission Designator | Microprocessor Number | |||||||||||||||||||||||||||||||||
2 | 1 | 15C | CC | 0.12500000 | 0.12500000 |
some individual PII (Personally Identifiable Information) available on the public forms may be redacted, original source may include additional details
This product uses the FCC Data API but is not endorsed or certified by the FCC