LoRa IoT Device Quick Start 1/5 www.ecoer.com LoRa IoT Device Quick Start Contents 1. Installation and Troubleshooting----------------------------------------------
2. Warranty Registration via ESS Pro App---------------------------------------
2 5 Log in www.ecoer.com or Ecoer Smart Service (ESS) Pro App >Systems
>Add Unit to get the newest guide. Manufacturer reserves the right to change specifications or designs without notice. 01.2023 LoRa IoT Device Quick Start 2/5 www.ecoer.com Part A. Installation and Troubleshooting Ecoer Smart Inverter (ESI) Unitary systems come equipped with remote monitoring and self-diagnostics technology designed to save dealers time when installing and servicing. Be sure to turn off the power supply for condensing unit prior to install the IoT device. Refer to the following steps to install this device. 1. To keep the best wireless network connectivity, choose one side of condensing unit that is further away from the wall to hang the IoT device. Use screw to tighten the device and belts to tie up the cable. 1-A The 1st row of panel 1-B 1-C Manufacturer reserves the right to change specifications or designs without notice. 1-D 01.2023 LoRa IoT Device Quick Start 3/5 www.ecoer.com 2. Unscrew the cable locker cap and securely fasten the waterproof joint to the reserved hole (plug has to be removed). 2-A Unscrew the locker cap 2-B 2-C 2-D Remove reserved plug 3. Plug the male blue terminal into CN11 (IoT) connector on main control board of condensing unit. Manufacturer reserves the right to change specifications or designs without notice. 01.2023 LoRa IoT Device Quick Start 4/5 www.ecoer.com Power ON the condensing unit and check if the IoT device is working properly. The normal working state of IoT device should be the blue LED
(No.1) is blinking with other LEDs light OFF. No. Color Indications Description 1 2 3 Blue Red IoT Device status Connection to Gateway Always OFF Always ON Blinking Always OFF Always ON Blinking Power off Booting Running Gateway connected Booting Gateway disconnected Green Connection to Local Unit Always OFF Local Unit connected Always ON Booting Blinking Local Unit disconnected LEDs Check LED the No.1 display after power ON for 40 seconds. Always ON Always OFF Blinking The IoT device boots failed. Replace a new one instead. Check if the IoT cable is securely connected with PCB of condensing unit. Check the display of No.3 LED after two (2) minutes. Blinking The problem disappears after replace IoT device. No Replace PCB of condensing unit. Always OFF Yes Check the display of No.2 LED after ten (10) minutes. Blinking Newly Install 1. Confirm the gateway is powered on and connected to the router accessed to internet. 2. The device have finished the warranty registration. Others Change a different install side of the condesing unit. Always OFF Done Model ELO01 Part Number Manufacturer reserves the right to change specifications or designs without notice. 01.2023 LoRa IoT Device Quick Start 5/5 www.ecoer.com Part B. Warranty Registration via ESS Pro App With the IoT device, Ecoer Inc. provides an easy way for dealers to help their customers complete registration via ESS Pro App in just minutes. Then dealers can monitor units live data and perform remote field settings for the condensing unit. Working alongside the Ecoer Customer Service Team, the dealer can guarantee the installation and servicing quality. Alternatively, homeowner / dealer / builder can register at www.ecoer.com. But it will not allow the dealer to monitor the system. Search ECOER on App Store or Google Play now. Download or update Ecoer Smart Service Pro App free on Steps of warranty registration *
1. 2. Create an ecoer account Add Unit (Register a new AC/HP) Sign an agreement with homeowner Scan/Input serial numbers to submit
*Log in www.ecoer.com or ESS Pro App >Systems >Add Unit to get the newest guide. Manufacturer reserves the right to change specifications or designs without notice. 01.2023 LoRa IoT Device Quick Start 6/5 www.ecoer.com FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help. To maintain compliance with FCCs RF Exposure guidelines, This equipment should be installed and operated with minimum 20cm distance between the radiator and your body: Use only the supplied antenna. Manufacturer reserves the right to change specifications or designs without notice. 01.2023 LoRa IoT Device Quick Start 7/5 www.ecoer.com 2023 ECOER INC. 43671 Trade Center Place, Suite 100 Dulles, VA 20166 Tel: 703-348-2538 www.ecoer.com Manufacturer reserves the right to change specifications or designs without notice. 01.2023