Z-Wave Plus Garage Door Tilt Sensor DISCLAIMER AND LIMITATION OF LIABILITY OTHER THAN THE LIMITED WARRANTY ABOVE, ECOLINK MAKES NO OTHER WARRANTY OR REPRESENTATION, AND HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. YOU ACKNOWLEDGE THAT YOU ALONE HAVE DETERMINED THAT THE PRODUCT WILL SUITABLY MEET THE REQUIREMENTS OF THE INTENDED USE. IN NO EVENT SHALL ECOLINK OR ANY OF ITS AFFILIATES BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT, CONSEQUENTIAL, OR MULTIPLE DAMAGES, INCLUDING BUT NOT LIMITED TO, LOST PROFITS, LOSS OR DAMAGE TO SOFTWARE OR DATA, OR DAMAGE TO EQUIPMENT ARISING OUT OF THE USE OF ANY PRODUCT, EVEN IF ECOLINK HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. FURTHER, IN NO EVENT SHALL THE LIABILITY OF ECOLINK OR ITS AFFILIATIES EXCEED THE INDIVIDUAL PRICE OF THE PRODUCT ON WHICH LIABILITY IS ASSERTED. By the act of use, setup or assembly of the product, you accept all resulting liability. If you as the purchaser or user are not prepared to accept the liability associated with the use of the product, you are advised to return the product immediately in new and unused condition to the place of purchase. Some states do not allow the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. LIMITED WARRANTY This limited warranty is provided by Ecolink Intelligent Technology (Ecolink) to you as the original purchaser of the product. Ecolink warrants this product to be free from defects in material and workmanship for a period of one (1) year from the date of original purchase. The determination of whether the product is defective shall be made by Ecolink in its sole discretion with consideration given to the overall performance of the product. If Ecolink determines that any product is defective, Ecolinks sole obligation and your sole and exclusive remedy shall be that Ecolink will replace the product. This warranty does not apply to damage caused by shipping or handling, or damage caused by accident, abuse, misuse, misapplication, ordinary wear, improper maintenance, failure to follow instructions or as a result of any unauthorized modifications. The foregoing limited warranty is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Ecolink. Ecolink neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. It is recommended that the customer check their equipment on a regular basis for proper operation RETURN POLICY Please visit us at www.discoverecolink.com/return to view our return policy. 2019 Ecolink Intelligent Technology Inc. Installation Guide PN TILT-ZWAVE5 The accelerometer based tilt sensor remotely monitors garages, hatches, Product Overview roll-up doors, or any other tilt surface. Verify doors are closed when you leave, and automate lights to turn on inside your home when you arrive, all from your computer, tablet or smart phone. Installation Instructions
(1) Identify location for Z-Wave Plus Tilt Sensor. It is very important that the Tilt sensor be located on the top section of a multi-panel garage door. This will be the first section to tilt when the door is opened and the last to move to the vertical position when closing. Features Quick installation, flush mount bracket with screws or tape Compatible with all Z-wave certified hubs & controllers Detects angle of a door and transmits open/close status Reports a tamper if the case is removed Specifications For indoor use only Operating frequency: 908.42, 916 MHz Operating temperature: 0 49C, 32 120F Operating humidity 5-95% non-condensing 1 CR123A battery Battery Life: 5 years Package contents 1 x Z-Wave Tilt Sensor 1 x CR123A batteries 1 x Installation Guide 1x Accessory Pack o 1x Mounting Bracket o 1x Double Sided Adhesive Tape o 2x Mounting Screws o 1x Mounting Bracket Screw IMPORTANT:
The Tilt sensor must be located on the top panel AND have the arrow on the side of the sensor pointing UP in order to operate properly. 2019 Ecolink Intelligent Technology Inc. PN TILT-ZWAVE5
(2) Mount the Tilt sensor mounting bracket a clean dry surface with the sensor screw facing the floor. The bracket can be mounted by the screws of adhesive tape. Caution: Use of the screws is only recommended for garage doors that are thicker than the screws are long. Use the adhesive tape for any garage door that is thinner than the length of the provided screws. bracket firmly onto the adhesive tape.
(4) Screws Mounting: Place the mounting bracket in the desired position on the garage door. Use the mounting bracket as a template to mark the location of the screw holes with a pencil. Drill a small hole through each of the marked locations. Use a screwdriver to fasten the mounting bracket to the door.
(5) Install 1x CR123A batteries provided in the package.
(6) Before the sensor is secured to the mounting bracket. Follow the inclusion instructions to verify successful communication with the Z-
Wave Controller.Follow the Network Inclusion steps in next section.
(7) After network inclusion, secure the sensor onto the mounting bracket with the sensor screw.
(8) Test the connection by opening and closing your garage and observing the open and close statuses. Sensor Adhesive Tape Mounting Bracket Sensor Screw Bracket Screws
(optional)
(3) Adhesive Tape Mounting: Make sure that the desired mounting location on the door is clean and dry. The adhesive tape can withstand the temperature and humidity conditions of a typical garage. However, it is recommended that the sensor be mounted when air or surface temperatures are not extreme. Installing the adhesive tape when the conditions are right promotes a good long-
lasting adhesive bond between the bracket and the surface of the door. Peel back the outer layer of one side of the adhesive tape, stick the tape to the garage door and press firmly. Peel back the outer layer on the other side of the tape and press the mounting The Z-Wave Plus Garage Tilt Sensor must be added to a Z-Wave Plus Network Inclusion network prior to use. To include the device in a network both the device and the network controller must be in inclusion mode at the same time. Refer to the instructions provided by the manufacturer of your specific controller for details on initiating the controllers inclusion mode. 1) Verify that the Z-Wave Plus controller you are using is compatible with the Z-Wave Plus Tilt Sensor. 2) Put your Z-Wave Plus Controller into add (inclusion) mode. 3) Insert the battery and press the learn button on the tilt sensor. 4) The LED on the front of the unit will turn off if network inclusion is successful. 2019 Ecolink Intelligent Technology Inc. PN TILT-ZWAVE5 1) Any Z-Wave Plus Device can be removed from any Z-Wave Plus Network Exclusion controller. Follow the directions to put your Z-Wave Plus Controller into exclusion mode. 2) Press the inclusion / exclusion button on the Z-Wave Plus Tilt 3) The LED in front of the unit will blink steadily if the network Sensor. exclusion is successful.
*Please refer to the LED status section for more information on the LED behavior Factory Reset Button Learn Button
(Inclusion/Exclusion) Notes:
Controller inclusion mode must be activated BEFORE starting sensor inclusion or exclusion mode. The device can only be included into one controller network at a time, and must be excluded from one network before inclusion in another. The Z-Wave Plus Tilt Sensor is equipped with a red LED. LED Status The state of the LED will change based on the state of the device. LED Blinking LED On LED blink
- Device in learn mode
- Device OTA (over the air) Update
- Tilt Detected/Restore, Tamper Detected/Restore The Z-Wave Plus Tilt Sensor will alert the user when the batteries Battery State become low. The Z-Wave Plus Tilt Sensor will continue reporting the state of the sensor until the batteries are completely depleted. The Z-Wave Plus Tilt Sensor can be factory defaulted by pressing and Factory Default holding the factory reset button for 5 seconds. 2019 Ecolink Intelligent Technology Inc. PN TILT-ZWAVE5 Z-Wave Plus is a wireless mesh network and data protocol that allows devices from many different manufacturers to interoperate. This device implements Z-Wave Plus Z-Wave Plus Specific Information functionality, Network Wide Inclusion. The following information is intended for software engineers working on Z-Wave Plus controllers and home automation enthusiasts to integrate the Z-Wave Plus device into their system. This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. For backwards compatibility with older Z-Wave Plus Controllers, the Basic Command Class is supported in the following manner. A Basic Report of 0xFF is Z-Wave Plus Command Class Basic Garage Open. A basic report of 0x00 is garage closed. Manufacturer ID Product Type Product ID 0x01 4A 0x00 05 0x04 AA This device also supports Network Wide Inclusion such that the device can be Network Wide Inclusion included into the Z-Wave network over the mesh network and not directly near the main controller. This mode is automatically activated after regular inclusion was not successful. This Z-Wave Plus Tilt Sensor has two Association groups of 1 nodes. Command Class Association Group one Group one is the lifeline group. The garage door tilt sensor will send Basic Reports with a value of 0x00 if the door is closed and 0xFF if the door is opened to all nodes in group 1. Commands Sent to Association Group One SENSOR CONDITION COMMAND CLASS AND VALUE CONFIGURABLILITY Tilt Detected Tilt Clear Notification report Type: HOME SECURITY (0x07) Event: Garage Open (0x02) Basic Report of 0xFF Notification report YES*
NO YES*
Case Tampered Case Closed Battery Level Type: HOME SECURITY (0x07) Event: Previous Events Cleared (0x00) Basic Report of 0x00 Notification report Type: HOME SECURITY (0x07) Event: Tampering Covering Removed
(0x03) Wake Up Notification Notification report Type: HOME SECURITY (0x07) Event: Previous Events Cleared (0x00) Battery Report of 0x01 to 0x64 is an estimated battery level. A level of 0x00 indicates that battery should be changed soon. A battery level of 0xFF indicates that the battery should be changed immediately. NO YES*
YES YES*
NO
*Notification Reports can be configured through the Notification Set of Notification Type 0x07, and status of: 0x00: This type of notification turned off. 0xFF: This type of notification turned on. This Z-Wave sensor is a Z-Wave generic Device Class of Z-Wave Device Class Information GENERIC_TYPE_SENSOR_NOTIFICATION, and a specific device class of SPECIFIC_TYPE_NOTIFICATION_SENSOR. Parameter Number Description Number of Default Min Max Bytes 1 2 1 1 3 0 500 0 10 0 10 5000 2
(0x01F4)
(0x0A)
(0x1388) 0 0 2 1 2 3 4 Number of attempts the device should attempt application level retries. Number of milliseconds between application levels retries. The tilt angle at which the garage door is considered closed. Byte value 0: 10 degrees Byte value 1: 30 degrees Byte value 2: 50 degrees The tilt angle at which the garage door is considered opened. Byte value 0: 30 degrees Byte value 1: 50 degrees Byte value 2: 70 degrees 2019 Ecolink Intelligent Technology Inc. PN TILT-ZWAVE5
* If you set Parameter 3 and 4 to the same byte value, Parameter 4 must be set first before Parameter 3 can be set. The opened tilt angle must be greater than the closed tilt angle The sensor uses industry standard elliptic key cryptography to encrypt all sensitive S2 Encryption communications. The DSK code is located on the device below the QR codes. The DSK is used for authenticating the encrypted command classes in the table above. A Security Enabled Z-Wave Controller must be used to fully utilize the product. COMMAND CLASS NAME VERSION SECURED USING S2 ENCRYPTION ASSOCIATION ASSOCIATION_GRP_INFO BATTERY BASIC CONFIGURATION DEVICE_RESET_LOCALLY FIRMWARE_UPDATE_MD MANUFACTURER_SPECIFIC NOTIFICATION POWERLEVEL VERSION WAKE_UP ZWAVEPLUS_INFO SECURITY_2 SUPERVISION TRANSPORT_SERVICE 2 1 1 2 1 1 4 2 8 1 3 2 2 1 1 2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes NA NA Yes NA This device complies with part 15 of the FCC Rules. Operation is subject to the FCC Compliance Statement following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Re-orient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a different circuit from Consult the dealer or an experienced radio/TV contractor for the receiver help. Warning: Changes or modifications not expressly approved by Ecolink Intelligent Technology Inc. could void the users authority to operate the equipment. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne peut pas provoquer d'interfrences, et (2) cet appareil doit accepter toute interfrence, y compris les interfrences qui peuvent causer un mauvais fonctionnement de la dispositif. FCC ID: XQC-TILTZWAVE5 IC: 9863B-TILTZWAVE5 2019 Ecolink Intelligent Technology Inc. PN TILT-ZWAVE5