Chime+Siren Manual Product Overview Z-Wave+ enabled device which provides open/closed position status Transmits open/closed status of eight wired inputs Reports tamper condition when cover is open Product Specifications For indoor use only Operating frequency: 908.42, 916 MHz Operation range: Up to 100 feet (30.5 meters) line-of-sight Operating temperature: 0 49C, 32 120F (ambient temperature) Line Powered 120v AC 60Hz US 24-hour battery backup. Adding via SmartStart To add via SmartStart, you will need the devices DSK QR-Code which is located on the back side of the device, on the packaging, and on a leaflet within the packaging. Apply power to the device by inserting the device into a wall receptacle, and the device will go into SmartStart inclusion mode. While in this mode, the sensor can be added to a Z-Wave controller that supports SmartStart. Please refer to the inclusion controllers manual for activating SmartStart. Page 1 of 10 Adding to a Z-Wave Network (Classic Inclusion Method) Make sure the device has power. Press the Add/Test Button which is the smaller of the two buttons, and the device will enter classic inclusion mode which implements both classic inclusion with a Node Information Frame, and Network Wide Inclusion. During Classic Inclusion mode, the Green LED will blink three times every three seconds. When Classic inclusion times-out, the device will blink red and green. Page 2 of 10 Led behavior for Inclusion Smart Start Started Classic Inclusion Started Blink Pattern Green LED Three Times Green LED Three Times every three seconds. Classic Inclusion Timed-Out Green and Red several times. Inclusion Successful (Authenticated S2) Green LED on solid Inclusion Not Successful (Self-Destruct) Red LED on solid To remove the device, place the controller into Remove or Z-Wave Exclusion mode. Press the smaller of the two buttons (Add/Test) following the Removing a Sensor from a Z-Wave Network same procedure to add for removal. Upon successful removal, the devices red led will come on solid for 1 second. Note: Any Z-Wave Inclusion Controller can remove a Z-Wave device regardless of manufacturer or which network the device is currently added to. The device is equipped with a non-user serviceable lithium-ion 24-hour battery backup to keep the device alive and active in the Z-Wave network for up to 24-
hours. Battery Backup The Z-Wave protocol is an interoperable, wireless, RF-based communications technology designed specifically for control, monitoring and status reading applications in residential and light What is Z-Wave?
commercial environments. Mature, proven and broadly deployed (with over 35 million products sold worldwide), Z-Wave is by far the world market leader in wireless control, bringing affordable, reliable and easy-to-use 'smart' products to many millions of people in every aspect of daily life. Certified Z-Wave devices regardless of manufacturer can work together to form a Z-Wave mesh network. Always on Z-Wave devices can act as repeaters in the mesh increasing range and redundancy. For a more complete look at Z-Wave technology for non-technologists, and to learn more about Z-Wave's role as a key enabling technology for the Internet of Things and connected objects, please visit www.z-wave.com. Page 3 of 10 This Z-Wave sensor is a Z-Wave generic Device Class of GENERIC_TYPE_AV_CONTROL_POINT (0x03), and a specific device class of SPECIFIC_TYPE_SOUND_SWITCH (0x01). Z-Wave Device Class and Command Class Information Manufacturer ID: MFG_ID_ECOLINK Manufacturer Specific Product Type: 0x0007 Product ID: 0x3975 To restore the device back to factory settings and remove it from any Z-Wave network. Remove the device from power-outlet. Hold the Add/Test button while Factory Default re-inserting siren into power-outlet and continue to hold Add/Test button for 10 seconds. During the 10 seconds of continuing to hold the Add/Test button the green LED with flash, and after 10 seconds the red LED will come on solid for 1 second indicating that the factory default of the device has been successful, and the device is ready to add back into a Z-Wave network. This sensor has one Association group (Lifeline) with only one node for that group. Group one is a lifeline group who will receive unsolicited messages relating to Association AC and Battery power notifications, and Device Reset Notifications. This sensor also supports Network Wide Inclusion such that the Sensor can be included into the Z-Wave network over the mesh network and not directly near Network Wide Inclusion the main controller. This mode is automatically activated after regular inclusion was not successful. While the device is included into a network, the learn button can be used to test the Z-Wave connection. It will transmit a System Heartbeat notification to the Test Mode node configured in Association Group 1. If the device receives an ACK + Supervision, the Green LED will turn on solid, otherwise the Red LED will turn on solid, and the device will then send a Wake-Up Notification. Page 4 of 10 Mapping of the Basic Command Class The Chime+Siren has the Basic Command Class mapped such that a Basic Set of 0x00 is always off. A Basic set of 1 is sound 1; 2 is sound 2, 5 is sound 5, etc. Finally a Basic Set of 0xFF is mapped to the primary sound which is either a siren or chime sound. Command Class Version Allowed unsecure when Z-Wave Command Classes Name Included with S2 Authenticated/Unauthenticated Allowed when Not included with S2 Comments Association 2 1 Association Group Information Device Reset Locally 1 Firmware Update Meta Data 5 Indicator 3 Manufacturer Specific 1 3 Multi Channel Association No No No No Yes Yes No Yes Yes Yes Yes Yes Yes Yes Device will factory reset when button us held as a user inserts siren into AC power then held for 10 seconds. 3 targets: The Z-Wave module, the STM32, and the external flash for sounds. Encapsulated with Supervision When included with S2 and Enabled With Configuration NA NA No NA No NA NA Page 5 of 10 Powerlevel 1 No Yes Security 2 1 Supervision 1 Transport Service 2 Version 2 Z-Wave Plus Info 2 Basic 2 Notification 8 Configuration 4 Sound Switch 1 Yes No Yes Yes Yes No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Support Authenticated &
Unauthenticated Basic Set of 0 to 255 maps to 0: off, and 1-255 enumerated sounds where 255 is a Siren sound. Any Report sent from the Siren is mapped 0: off and 255: Sound playing. No NA NA NA NA NA NA Yes NA No Page 6 of 10 Parameter Name Configuration Command Class 1 Swap Siren and Chime Sound mapping. 2 Periodic heartbeats 3 Encapsulate Unsolicited Notifications/Reports in Supervision Description 0: A Basic Set of 0xFF starts playing Siren. 1: A Basic Set of 0xFF starts playing Chime. The number of seconds between automatic Heartbeat Notifications. Encapsulate Unsolicited Notifications in Supervision Get requests. 0: Disabled 1: Enabled Default Min Max 0 0 1 3600 0 120 0 86400 1 4 Sound Volume 5 Total Number of Sounds Sound volume as a percentage for non-emergency sounds. Read only 100 100 0 0 100 100 Available The Chime+Siren Implements two notification types for Power Management and System level notifications which are sent unsolicited to the Lifeline Association Notification Types Group 1. Power Management (0x08) Name Value Description Mains status Mains status Battery load status Battery level status 0x02 0x03 0x0C 0x0D AC mains disconnected AC mains re-connected Battery is charging Battery is fully charged Page 7 of 10 Backup battery level status 0x10 Back-up battery is low System Software Failure (Manufacturer Proprietary Failure Code Provided) System (0x09) Heartbeat 0x04 0x05 Failure codes->
0x33 Watchdog Reset on the Z-Wave Module 0x55 Watchdog Reset on the STM32 This is sent out periodically as configured by the Configuration command class. There are 14 included sounds within the Chime+Siren, and the device can play sounds from the SD card either overriding the build-in sounds or adding to them. Sounds Sounds are played with the Sound Switch Command Class, the Basic Command Class, and optionally with the Indicator Command Class. Volume is controlled with the buttons, the Configuration Command Class, and the Sound Switch Command Class. When a sound is played with the Basic Command Class and Indicator Command Class, then it plays at the current configured volume level. Sound Number Name 1/255 siren 2 chime_front_door 3 chime_back_door 4 chime_auxillary_door Description Intrusion Alarm Front Door Opening sound Back Door Opening Sound Side Door Opening Sound 5 chime_window Window Opening Page 8 of 10 6 doorbell 7 error 8 Exit_delay 9 entry_delay 10 away 11 stay_home 12 smoke_alarm 13 co_alarm 14 disarmed DoorBell Sound Action Canceled Sound A loud chirp every second for 30 seconds then every half second forever or another 30 seconds. A constant tone. Security panel in away mode. Security panel in Stay/home mode where the PIRs are not active. UL Specified UL Specified Happy sound. Manually Adjusting the Volume The volume buttons on the side of the device can override the volume. Press the volume + to make the volume louder and to make it quieter. Emergency sounds like the siren will still play at full volume regardless of the current volume setting. SD-Card To override the built-in sounds via the SD-Card format an SD-card with a FAT16 filesystem. The sounds on the SD card must start with a decimal number followed by the name of the sound with a .wav file extension. The encoding for the wav file must be mono TBD. S2 Encryption The device uses industry standard elliptic key cryptography to encrypt all sensitive communications. The DSK code on the device in the QR code and printed below it is used for authenticating the encrypted command classes in the table above. A Security Enabled Z-Wave Controller must be used in order to fully utilize the product. Page 9 of 10 Re-orient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a different circuit from the receiver Consult the dealer or an experienced radio/TV contractor for help. FCC Compliance Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Warning: Changes or modifications not expressly approved by Ecolink Intelligent Technology Inc. could void the users authority to operate the equipment. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne peut pas provoquer d'interfrences, et (2) cet appareil doit accepter toute interfrence, y compris les interfrences qui peuvent causer un mauvais fonctionnement de la dispositif. FCC ID: XQC-ISZW7ECO IC: 9863B-ISZW7ECO Limited Warranty This limited warranty is provided by Ecolink Intelligent Technology (Ecolink) to you as the original purchaser of the product. Ecolink warrants this product to be free from defects in material and workmanship for a period of one (1) year from the date of original purchase. The determination of whether the product is defective shall be made by Ecolink in its sole discretion with consideration given to the overall performance of the product. If Ecolink determines that any product is defective, Ecolinks sole obligation and your sole and exclusive remedy shall be that Ecolink will replace the product. This warranty does not apply to damage caused by shipping or handling, or damage caused by accident, abuse, misuse, misapplication, ordinary wear, improper maintenance, failure to follow instructions or as a result of any unauthorized modifications. The foregoing limited warranty is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Ecolink. Ecolink neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. It is recommended that the customer check their equipment on a regular basis for proper operation2012/19/EU (WEEE directive): Products marked with this symbol should not be mixed with general household waste. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. Designed in Carlsbad, CA www.discoverecolink.com Page 10 of 10