HD16(RF) Mk10D SER100 Version V1.0 Description Modification Date 2016-05-15 First Edition V1.1 2016-05-19 V1.2 2016-11-30 1The last Credit Tokens 5 10 2 time/date of the last 10 credit tokens 3kwh values from the last 10 credit tokens 4the last 10 engineering tokens 5time/date of the last 10 engineering tokens 1 10kWh Credit LED Enter 2 RF TP3 2580 Back Modified By Wenke Li
(EDMI Shenzhen) Wenke Li ApplicabilityScope HD16(RF) For SER100 HD16_V1.0_S001 HD16(RF) For SER100 HD16_V1.0_S002 AnTao HD16(RF) For SER100 HD16_V1.0_S006 V1.3 2016-12-2 Enter 1 V1.4 2017-04-21 8dbm AnTao AnTao HD16(RF) For SER100 HD16_V1.0_S006 HD16(RF) For SER100 HD16_V1.0_S008 1/31 TableofContents 1. Introduction .......................................................................................................................3 2. External Features, Dimensions, Liquid Crystal and Installation Diagram ............................................................................................................................................4 3. Electrical Parameters ................................................................................................7 2.1 External Features.......................................................................................................4 2.2 LiquidCrystal.............................................................................................................4 2.3 ExternalAppearance&Dimensions.................................................................5 2.4 InstallationDimensions&Method.....................................................5 3.1 OperatingVoltage.............................................................................................7 3.2 OperatingCurrent..............................................................................................7 3.3 RFCommunicationsParameters................................................................7 3.4 KeysSpecifications.............................................................................................7 3.5 DisplaySpecifications.......................................................................................7 3.6 OperatingEnvironment.....................................................................................7 3.7 Interface....................................................................................................................8 4. Keys Definitions .........................................................................................................8 5.LEDLCD LED Indicators, Backlight Control ,LCD Iconsand Buzzer Alarm ...................................................................................................................9 7. Default Display Interface .................................................................................13 6. PoweredonandPoweroffandAutoPowerOff..............................12 6.1 PowerOnStep1 InitializetheDevice.......................................12 6.2 PoweronStep2 EstablishtheCommunications...........................12 6.3 .................................................................................................................................12 8.HASH Interface...................................................................................................................14 9.TOKEN Interface................................................................................................................15 10. RelayClose.............................................................................................................17 11 SerialSettingInterface.................................................................................18 12. PageChangeover....................................................................................................19 13. CommunicationsProcess/Flow..............................................................................21 13.1 InitializationCommunicationsFlowchart.....................................21 13.2HASH CommunicationsFlowchart.............................................................23 13.3Token CommunicationsFlowchart............................................................24 14 batteryandcharger..........................................................................................26 15.RF RFModuleproductiontestfunction....................................................26 16. Notice......................................................................................................................27 1 Appendix1:HASH CommandCodeList......................................................27 2/31 1. Introduction CIU(Customer Interface Unit) CIU TOKEN TOKEN CIU (Customer Interface Unit) is for use with electricity meter. Using this device, users may check the meters energy balance (energy credits remaining), relay status and other information, input TOKEN serial number, and complete TOKENs functionality. HD16(RF) Mk10D SER100RFmodem This manual is applicable to HD16(RF) equipment and for use with electricity meter SER100RFmodem Target audience for this manual are: Technical, engineering, testing personnel, etc. This manual is not recommended to be given to customers (end-users). CIU This manual will provide the CIUs parameters, specifications, operation method, technical principle and process to the relevant personnel. Please read this manual sequentially according to its Table of Contents. 3/31 External Features, Dimensions, Liquid Crystal and Installation Diagram 2. 2.1 External Features HD16 FrontView HD16 Base HD16 BackView 2.2 Liquid Crystal 4/31 2.3 External Appearance & Dimensions HD16 ActualDimensions Length95mm Width149mm Depth29mm 2.4 Installation Dimensions & Method 5/31 Direction 1 Direction 2 1BA Useafirstscrew(denotedasitemB)tomountandsecureCIUbracket(denotedasitemA)tothe wall. 2 HD16C 1A Next,moveHD16(denotedasitemC)inthedirectionofDirection1toplaceCsbackgroove initiallyintotopportionofCIUbracket(denotedasitemA). 3 HD16C 2 Next, move HD16 (denoted as item C) downwards in the direction of Direction 2 to fit C securelyonCIUbracket(denotedasitemA). 4DEAC Useasecondscrew(denotedasitemD)tosecuretheCIUandCIUbracket(itemsAandC)at pointEofCIU(topofCIU). 6/31 3. Electrical Parameters 3.1 Operating Voltage 3.2 Operating Current 5V Powerbylithiumbatteryor5VDC 1LED<=24mA WhenCIUisnotcommunicatingandLEDandbacklightareOFF(switchedoff):<=24mA 2 2 LED LCD60mA WhenCIUisnotcommunicating,2LEDsareON(litup),thepressedkeysbacklightisON(lit up)andtheLCDbacklightisON(litup):Less than 60mA 3 120uA currentlessthan100uAinsleepmodel 3.3 RF Communications Parameters HD16RF RFfrequent:CheckManufacturingCodes FSKModulation:FSK 8dBmRFPower8dBm RFISM433MHz915MHz 10Kbps 38.4KbpsCommunicateRate38.4Kbps 100m CommunicateDistance:Morethan100m Capacitive-touch keys are used. 3.4 Keys Specifications 3.5 Display Specifications 3.6 Operating Environment Operating Temperature Range10 +45 Limit Temperature Range25 +55 StorageTemperature Range5 +35 LED 1 LED 1 LED 1 Character-segment LCD screen Indicator LED light: 1 x yellow LED, 1 x green LED, 2 x red LED, Humidity Range<95% No condensation 7/31 3.7 Interface 4. Keys Definitions MicroUSB 09 NumberKeys Power powerkey:useforPowerandPoweroff back key Usedfor Deletion exitingprogram enter key Usedfor ConfirmingUsersinputs
* key Usedfor pagedown
# key Usedfor pageup 8/31 5.LEDLCD LED Indicators, Backlight Control ,LCD Iconsand Buzzer Alarm LCDHD16 LCD LCDwilldisplayallsegmentwhenHD16startingup LCD LED LCDiconsandLEDindicatordescriptionareasshowninthetablesbelow:
LED LED/Backlight Controls Description Credit RXD TXD LED<=10kWh When thisLEDispermanently ON(litup),itindicatesEnergy Credits Remaining(CurrentEnergyBalance)<=10kWh LED 200ms WhenthisLEDisON(litup)for200ms,itindicatesCIUisreceivingaframe andparsingtheframecorrectly. LED 200ms WhenthisLEDisON(litup)for200ms,itindicatesCIUistransmittinga frame. KEY LCD
(KEYbackightand LCDbacklight) 30s Whenakeyistouched,thesebacklightsareON(litup)for30s,thenthey areOFF(switchedoff). LCD LCD Display Icon &
Indicator Description ThisiconisdisplayedtoindicateCIUhasestablishedcommunications withtheMetersuccessfully. ThisiconisdisplayedtoindicateCIUiscommunicatingwiththeMeter now. Bars batterylevel 0 1 0~5%
5%~25%
9/31 LCD LCD Display Icon &
Indicator Description 2 3 25%~75%
75%~100%
HD16 HD16chargeby5VDC ThebatteryofHD16isfull This Unit of Measurement (UOM) icon changes according to the electrical quantity (Energy, Voltage, Current or Power) that is being displayedontheLCDasexplainedbelow:
kWh ThisiconisdisplayedtoindicateunitofEnergyiskilo Watthour. kW ThisiconisdisplayedtoindicateunitofPoweriskilo Watt. Forexample,thisisthenitforInstantaneous
(Active)Power inTanzania,Malaysiaand Postpaymenus. ThisiconisdisplayedtoindicateunitofPoweris Watt. Forexample,thisistheUnitforMaximumPowerLimit(MPL)/
LoadLimit inTanzaniamenu. ThisiconisdisplayedtoindicateunitofCurrentis Ampere. ThisiconisdisplayedtoindicateunitofVoltageis Volts. W A V ThisiconisdisplayedtoindicateCIUfailstocommunicatewithMeter andgoesintoWaitingmode. ThisiconisdisplayedtoindicatethecontentreadbyCIUisempty;or nosuchdataitem. Thisiconisdisplayedtoindicatecommunicationshasfailed. EEPROM This icon indicates that writing to EEPROM has failed. This icon is displayed to indicate CIU fails to detect its Keypressing moduleduringCIUspoweringon. 10/31 Description LCD LCD Display Icon &
Indicator Buzzer Alarm 10 1 The buzzer alarm 1 second every10 second Description ENTER 1 The buzzer will alarm if the Energy Credits Remaining falls below the AlarmoffThreshold, LongpressENTERkeyfor 1 secondtocancelthe alarm 11/31 6. PoweredonandPoweroffandAutoPowerOff HD16willPowerOnorPoweroffbyPressthekeyforlong 5v Ifthebatterylevellow,theHD16wouldnotPowerOn,andtheHD16needtoPowerby5VDC 6.1 Power OnStep1 Initialize the Device LCD LCD AllsegmentsareON(litup) LED LED LED 0.5s LEDstaketurnstobeON(litup)andOFF(switchedoff);EachLEDislitfor0.5s. LCD KEY LCDbacklightandKEYsbacklight:Lit(ON) 1.5 Thisprocesslastsfor1.5seconds LCD LCDsallsegmentsareON(litup)whenMeterispoweredonasindicatedinthediagram below:
6.2 Power onStep 2 Establish the Communications LCD Duringthisperiod,theLCDdisplays 1 Mainscreendisplays 6.3 pressthiskeyforlongcanpoweroffHD16 HD16willpoweroffautoinbellowcondition 11 nokeypressedin1minute 21RFdonotworkin1minute 12/31 7. Default Display Interface ItemNo. 1 2 3 DisplayScreen Explanation of DisplayedContent 01 No.01Screen
:0.01kWh CreditsRemainingis0.01kWh 02 No.02Screen 211493090 MeterSerialNumberis211493090 03 No.03Screen rELayy: relayclose rELayn: relayopen Inthisinterface,thekeypressedfunctionsare:
1 HASHtoken( HD16) Numerickeys:UsethesekeysforinputtingHASHcode, token,andpassword(for configurationHD16). 2*
*key:Usethiskeytoflip(change)displaytothenextdisplayitemofkeypressed menu. 3# key Usethiskeytoflip(change)displaytothe previousdisplayitem. 1 Back key Notused 2 Enter key Usethiskeytoconfirmtheinputofnumbers. 13/31 8.HASH Interface 1~2 HASH Input1or2numbersandpressENTERKey,getintotheHASHinterface LCD Inthisinterface,theLCDdisplays 1 HASH MainScreendisplaystheHASHitem. 2 HASH NumberdisplayedatthelowerleftcornerisHASHNumber 3 uniticon:DisplaystheUnitofmeasurementthatcorrespondstothe electricalquantitythatiscurrentlydisplayed. Inthisinterface,thekeypressedfunctionsare:
1 HASHtoken Numerickeys:UsethesekeysforinputtingHASHcode,token,andpassword. 2* key Notused 3# key Notused 4 Back key ReturntoMenuDisplayInterface. 5 Enter key Usethiskeytoconfirmtheinputofnumbers. HASH 08 HD16 LCD Example: InputHashcommand08andpressENTERkeyonHD16,LCDwilldisplayasfollow 14/31 9.TOKEN Interface 20 token Input20numbersandpressENTERKey,getintothetokeninterface LCD Inthisinterface,theLCDdisplays 1 MainScreendisplaysthenumbersthatareinput. 2 Numberdisplayedatthelowerleftcorneristhelengthofnumericinput(i.e.the numberofdigitsinputsofar) Inthisinterface,thekeypressedfunctionsare:
1 Numerickeys: Notused 2* key Notused 3# key Notused 4 Back key token, ReturntoMenuDisplayInterface.Iftokentransmissionprocessisinterrupted,user needstoreinputthetoken(numbers). 5 Enter key Notused token DisplayCode Explanation Energy replenishment/ topup successful(Energyunitsareincremented). is Authenticationfailed Validationfailed Tokenisolderthantheoldesttokeninthemeter Tokenhasalreadybeenusedinthismeter Meterkeyhasexpired 15/31 DisplayCode Explanation OverflowinCreditBalance Tokenhadanerrorexceptforoverflow,1stKCT, 2ndKCT FirstKeyChangeToken(1stKCT)hasbeenentered SecondKeyChangeToken(2ndKCT)hasbeen entered Communications energyreplenishment/topuptofail.
(timeout) causes failure link 16/31 10. RelayClose 1HD161CLoSE 1)InMenuDisplayInterfacePressENTERKeyforlong,HD16willdisplay1CLoSE 21HD160ESC10 2 0 2)Pressnumberkey1HD16display0ESC10,Thelast2numberscountdown,Pressnumber key0wouldstopthenumberscountdownbeforeitcountto0. 3HD16CLoSing yano 3)HD16displayCLoSingwhenthenumberscountto0,HD16sendcommandtoclosetherelay ofmeter,thenreadtherelaystatusofmeter. ifrelaycloseHD16willdisplayya,ifrelaynotcloseHD16willdisplayno. 17/31 11 SerialSettingInterface 755204ENTER Inputnumbers755204andpressENTERkey,getintotheserialsettinginterface 9 ENTER LCD yaErrE Thenumberinputnumbersislimitednotmorethan9,PressENTERkeywillensuretheserial LCDwilldisplayyaifstoretheserialsuccess,ordisplayErrE Notice 1 HD16000000000HD16 1)IfHD16neverbesettingserialnumber,ortheserialnumbersetto000000000,HD16willget intoSerialSettingInterfacewhenstartup 2HD16 2)HD16willinitializewhenexitSerialSettingInterface 18/31 12. PageChangeover 19/31 20/31 13. CommunicationsProcess/Flow 13.1 Initialization Communications Flowchart 21/31 22/31 13.2 HASH Communications Flowchart HASH
------
HASH N 3s Y
<3 N Err-1 Y LCD 23/31 13.3 Token Communications Flowchart 24/31 25/31 14 batteryandcharger HD16(RF) 500mAh 1000mAh 300 Battery: HD16(RF) have 500mAh or 1000mAh battery inside, the battery can be charged 300 cycles
:Thechargershouldcontentrequirementsasbellow:
DC5V 300mA 500mA Outputvoltage:DC5V;Outputcurrent:morethan300mAor500mA(accordingtobattery volume) inaccordancewithlocalrequirements. OnechargerforHD16asbellow:
InputAC100~240V/50~60HZ/150mAMax OutputDC5V/1.2A
:Thechargerappearanceasfollow 15.RF RFModuleproductiontestfunction TP3 HD16 2 Back WhenthetestpointTP3shortreceived,HD16intothepowertestinterface,thistimecanbe measured by spectrum analyzer to determine the transmission power, after 2 minutesor presstheBackkeytoexitthepowertestinterface. 2580HD16 RF 2 Back Through the keyboard input 2580, HD16 can enter the receiver sensitivity test interface, whentheRFmodulereceivesthedatathatwillbesentoutthroughtheserialport,after2 minutesorpresstheBackkeytoexitthereceiversensitivitytestinterface. 26/31 16. Notice HD16 ic 15s IfHD16skeypadencountersstrongelectrostaticinterference,itmaycauseonekey(button) tobetriggeredcontinually. HD16s key (button) IC has automatic adjustment function: After about 15s, the IC will do autoadjustment to this key (button). After adjustment, this key (button) will function normallyagain). 15s IC 15s 15s If any key(button) is pressed(held down) continually for about15s,theautomatic adjustmentfunctionbyHD16skey(button)ICwillbetriggered.Usermayfindthatthiskey
(button)cannotbetriggeredmeanwhile(i.e.withinthisabout15speriod). Soifthisphenomenonoccurs,pleasewaitfor15s. 1 Appendix1:HASH CommandCodeList HASH Register Present Average Power in kW Total User Consumption to Date Meter Serial Number CIU software version Total user credit entered to Date Meter Software version Wh per pulse Tariff index no. Load limit(kW) token value Power purchase token of last time Register Number E033 1E00
(Assuming TOU ch1) F002 CIU feature F04B F003 FF30 F202 F233 F220 Power purchase token of last 2nd time Power purchase token of last 3rd time F221 F222 Power purchase token of last 4th time F223 Power purchase token of last 5th time F224 Data Type Float Float Example Value 2.57 78.37 Unit kW kWh kWh Wh kW Char(11) Float String Float Byte Long String String String String String 123456789 01 V1.0S002
-0.10 1.43L 0.2 1 0.00 1892322345 2304456000 1892322345 2304456000 1892322345 2304456000 1892322345 2304456000 1892322345 2304456000 27/31 1 2 4 5 6 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 38 39 40 41 42 43 44 45 46 47 48 49 Time and date of last valid token loaded Time and date of last 2nd valid token loaded Time and date of last 3rd valid token loaded Time and date of last 4th valid token loaded Time and date of last 5th valid token loaded Amount purchased last time Amount purchased last 2nd time Amount purchased last 3rd time Amount purchased last 4th time Amount purchased last 5th time Occurrence time of last power off event Date and time of last tariff index change Date and time of last 2nd tariff index change Date and time of last 3rd tariff index change Number of tariff index changes Supply Group Code (SGC) Key revision number F225 F226 F227 F228 F229 F22A F22B F22C F22D F22E FC20 F230 F231 F232 Data Data Data Data Data Long Long Long Long Long Time/Date Time/Date Time/Date Time/Date F22F 901132 1 Short constant constant Present Power Factor E026 Energy measured since last format Power consumption in current month Power consumption of last month Power consumption of 2nd month Power consumption of 3rd month Power consumption of 4th month Power consumption of 5th month Power consumption of 6th month Power consumption of 7th month Power consumption of 8th month Power consumption of 9th month Power consumption of 10th month 1E00
(Assuming TOU ch1) 0000 0200 0400 0600 0800 0A00 0C00 0E00 1000 1200 1400 Float Float Float Float Float Float Float Float Float Float Float Float Float 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 4.50 3.70 5.20 20.00 10.00 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 200 123.45 s s s s s kWh kWh kWh kWh kWh s s s s 78.59 kWh 78.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 123.45 123.45 kWh kWh kWh kWh kWh kWh kWh kWh kWh kWh kWh 28/31 50 51 55 56 57 58 59 60 61 62 63 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 Power consumption of 11th month Power consumption of 12th month Present Phase A average Power Present PhB power Present PhC Power Present PhA Current Present PhB Current Present PhC Current Present PhA Voltage Present PhB Voltage Present PhC Voltage 1600 1800 E030 E031 E032 E010 E011 E012 E000 E001 E002 Float Float Float Float Float Float Float Float Float Float Float 123.45 123.45 0 0 2577 0.00 0.00 11.38 0.00 0.00 226.32 kWh kWh W W W A A A V V V Power purchase token of last time F310 Power purchase token of last 2nd time Power purchase token of last 3rd time F311 F312 Power purchase token of last 4th time F313 Power purchase token of last 5th time F314 Power purchase token of last 6th time F315 Power purchase token of last 7th time F316 Power purchase token of last 8th time F317 Power purchase token of last 9th time F318 F319 F321 F320 Power purchase token of last 10th time Time and date of last valid token loaded Time and date of last 2nd valid token loaded Time and date of last 3rd valid token loaded Time and date of last 4th valid token loaded Time and date of last 5th valid token loaded Time and date of last 6th valid token F325 F322 F324 F323 String String String String String String String String String String Time/Date Time/Date Time/Date Time/Date Time/Date Time/Date 1892322345 2304456000 1892322345 2304456000 1892322345 2304456000 1892322345 2304456000 1892322345 2304456000 1892322345 2304456000 1892322345 2304456000 1892322345 2304456000 1892322345 2304456000 1892322345 2304456000 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 s s s s s s 29/31 loaded Time and date of last 7th valid token loaded Time and date of last 8th valid token loaded Time and date of last 9th valid token loaded Time and date of last 10th valid token loaded kwhvaluesfromthelastcredittoken kwh values fromthe last2nd credit token kwhvaluesfromthelast3rd credit token kwhvaluesfromthelast4th credit token kwhvaluesfromthelast5th credit token kwhvaluesfromthelast6th credit token kwhvaluesfromthelast7th credit token kwhvaluesfromthelast8th credit token kwhvaluesfromthelast9th credit token kwh values from the last 10th credit token thelast engineeringtoken thelast2nd engineeringtoken thelast3rd engineeringtoken thelast4th engineeringtoken thelast5th engineeringtoken thelast6th engineeringtoken thelast7h engineeringtoken thelast8th engineeringtoken F326 F327 F328 F329 F330 F331 F332 F333 F334 F335 F336 F337 F338 F339 F340 F341 F342 F343 F344 F345 F346 F347 Time/Date Time/Date Time/Date Time/Date Long Long Long Long Long Long Long Long Long Long String String String String String String String String 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 4.50 3.70 5.20 20.00 10.00 4.50 3.70 5.20 20.00 10.00 s s s s kWh kWh kWh kWh kWh kWh kWh kWh kWh kWh 2979440793 8320483066 2979440793 8320483066 2979440793 8320483066 2979440793 8320483066 2979440793 8320483066 2979440793 8320483066 2979440793 8320483066 2979440793 30/31 108 109 110 111 112 113 114 115 116 117 118 119 thelast9th engineeringtoken thelast10th engineeringtoken time/dateofthelastengineering token time/dateofthelast2nd engineering token time/dateofthelast3rd engineering token time/dateofthe last4th engineering token time/dateofthe last5th engineering token time/dateofthe last6th engineering token time/dateofthe last7th engineering token time/dateofthe last8th engineering token time/dateofthe last9th engineering token time/dateofthelast10th engineering token F348 F349 F350 F351 F352 F353 F354 F355 F356 F357 F358 F359 String String Time/Date Time/Date Time/Date Time/Date Time/Date Time/Date Time/Date Time/Date Time/Date Time/Date 8320483066 2979440793 8320483066 2979440793 8320483066 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 2011-08-27 14:15:27 15.19Labellingrequirements. Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemust acceptanyinterferencereceived,includinginterferencethatmaycauseundesired operation. 15.21Informationtouser. AnyChangesormodificationsnotexpresslyapprovedbythepartyresponsiblefor compliancecouldvoidtheuser'sauthoritytooperatetheequipment. 31/31 15.105Informationtotheuser. ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigital device,pursuanttopart15oftheFCCRules.Theselimitsaredesignedtoprovide reasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.This equipmentgeneratesusesandcanradiateradiofrequencyenergyand,ifnotinstalledand usedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradio communications.However,thereisnoguaranteethatinterferencewillnotoccurina particularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioor televisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,the userisencouragedtotrytocorrecttheinterferencebyoneormoreofthefollowing measures:
Reorientorrelocatethereceivingantenna. Increasetheseparationbetweentheequipmentandreceiver. Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiver isconnected. Consultthedealeroranexperiencedradio/TVtechnicianforhelp. 32/31